Attachment_2_-_Electrical.pdf
PDF 1 MB Posted
- Attached to
- Audio Visual and Teleconferencing Equipment Federal contract opportunity
- Solicitation number
- FA4620-14-R-A006
About this file
Attachment 2 - Electrical As Designed
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment_003_Extend_Proposal_Due_Date.pdf | ||
| Attach_01_-_Questions.pdf | ||
| SF30_Amendment_002.pdf | ||
| Attachment_3_-_Electrical_ _Telecomm.pdf | ||
| Attachment_4_-_Addendum_to_52.212-1_Change.pdf | ||
| Attachment_1_-_Site_Visit_Questions_V5-Final_June_2nd_Release_-_WG_Conf_Room.pdf | ||
| SF30_Amendment.pdf | ||
| Attachment_5_-_Highlights.pdf | ||
| FA4620-14-R-A006_Wing_AV_and_Teleconferencing.pdf | ||
| Attachment_A_-_Courtroom_Drawings.pdf | ||
| Attachment_C_-_Wg_Conference_Room_Drawings.pdf | ||
| Attachment_B_-_JA_Conference_Room.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
UP
JJJ
J J J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J J
J
J
J
J
J
G
G
G
G
G
G
G
G G G G
G
G G
G
G
G
G
G
G
G
G
G G G G G G G G G G G G G G G G G G G G G G G
G G
G G
G G
G
G G G G G G G G G G G G G G G
141st COS
92nd FLT. SAFETY
ELEV.
E001
JAN.
100C
92nd/141st GND.
SAFETY
107A
W.S.M.
107D MEN
STAIR
S001
LOBBY
100A
VEST.
100B
WOMEN
101E
AV
101D
COURT ROOM
101B
STOR.
101C
CORRIDOR
C003
JURY DELIB.
102A
RECEPTION
CT. RM. VEST.
101A
JUDGE
CHAMBERS
103A
TOILET
103B
TOILET
102B
CCL
CEL
W.W. DEF WIT.
W.W. GOV'T.
RES. ATTY
OIC
OIC
L.O.S.
DSJA
132 SJA
LGL. ASST.
CORRIDOR
C002
LIB. CONF
NCOIC
127B
FILE STOR
100D
CIV. LAW
127A
CT. REP.
FILE STOR 2
125A
COC
BREAK
NCOIC
PARAL. OPEN
OFFICE
STAIR
S003
GFCI
+36"
GFCI
+36"
GFCI
+36"
GFCI
+36"
GFCI
+36"
EWC
/1 E-10
L-5
EXOTHERMIC WELD TO CONCRETE
ENCASED REBAR IN BUILDING
FOUNDATION FOOTING
(TYPICAL).
SEE
FLOOR BOX, TYP.
SEE
FOR GROUND WELL DETAIL
#1/0 AWG
MINIMUM
EXOTHERMIC WELD TO
CONCRETE ENCASED
REBAR IN BUILDING
FOUNDATION FOOTING
TYPICAL.
SEE
L-4
PROJECTOR
FLOOR BOX TYPICAL
CLG
CLG
X.A
X.B
X.D
X.5
X.5
X.6
X.6
Z.DZ.D
A
A
Z.6
Z.6
Z.5
Z.5
Z.4
Z.4
Z.3
Z.3 Z.1
Z.B
Z.C
Z.2
Z.A
#1/0 CU MINIMUM
(TYPICAL)
PRINTER
PROJECTOR
PRINTER
+8" FROM
FLATFORM
TV
+66"
KIOSK
PRINTER
TV
+66"
TV
+66"
TV
+66"
TV+66"
TV+66"
PRINTER
PRINTER
(2)PRINTERS
TV+66"
MIC
CM
REF
GFCI
ELEVATOR CONTROLLER
DISCONNECT SWITCH
X.7
PROJ SCREEN
AND SWITCH
PROJ SCREENPROJ SCREEN
SWITCH
PROJ SCREEN
SW
ITCH
SENSOR XFMR
SENSOR XMFR
SENSOR
XFMR
WINDOW
SHADES
GFCI
SEE
TYP.
14 18
7 23
2 2
2 2
MIC6
TV
+66"
18 29
T
T
T
PANEL
L-5
PANEL
L-4
PANEL
L-4
PANEL
L-2
10,12,149,13,15
1,3,5 7,11 19,21,23
25,27,29
1,3,5
TV
+66"
GFCI
CONTROL
(SUMP PUMP)
PANEL
RECEPTACLE
PUMP
CONTROL
PANEL
SUMP PUMP
2,4,8
16,18,20
28,30 22,24,26
14,16,18
19,21
20,22
7,9,11 13,15,17
19,21,23
2,4,6
8,10,12
14,16,18
20,22,24
ELEVATOR CAB LIGHTS
DISCONNECT SWITCH
MSB-1/ 6
22 SHREDDER
GFCI
WINDOW SHADES
SWITCH
23,27
SP-1
25,27
6E-704
E-704
E-704
E-704
E-704
WINDOW
SHADES
GARBAGE
DISPOSAL
CM31
1/8" = 1'-0"E-101
1 POWER FIRST FLOOR PLAN - EAST WING
SHEET
IDENTIFICATION
1 2 3 4 5
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
S
IZ
E :
FI
LE
N
A M
E:
IS
SU
E D
A
TE
C O
N
TR
AC
T
N O
S O
LI
C
IT
AT
IO
N
N O
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
C
KD
B Y:
US Army Corps of Engineers ®
" x
4"
D
C
B
A
FI
LE
N U
M
BE
R
P
LO
T
SC
A
LE
P
LO
T D
AT
E:
SHEET OF
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
/8
'-0
7/
/ 2
4:
: 5
PM
FY
1 2
W in g H ea d q ua rt e rs
JU
LY
W
2D W
W
2D W
-1 2-
C -0
Seattle District
E . A
C
AC
IO
L.
F
LO
R
ES
C
A
E . A
C
AC
IO
P N
G
JK
Z8 6-
-E
LE
C -C
EN
TR
AL
.rv t
6/
1-
-1
E-101
SE
AT
TL
E
D
IS
TR
IC
T
SE
A T
TL
E , W
AS
H
IN
G
T O N
S . E
N G
LI
SH
PO
W
ER
F
IR
S T
F L O
O R
P
LA
N
EA
S T
W I N
G
P R O
JE
C
T N
AM
E
E -1
Final Design - Issued For Construction (Submittal #5)
Pr oj ec t N um be r
PLAN NORTH
04 8 16268
SCALE: 1/8"=1'-0"
1 SINK, URINAL AND TOILET SENSOR EQUIPMENT CONNECTION. PROVIDE
120V POWER CONNECTION TO TRANSFORMER.
MOUNT RECEPTACLE ON PARTIAL HEIGHT WALL.
MOUNT RECEPTACLE IN CASEWORK.
PROVIDE ENCLOSED EXTERNALLY OPERABLE FUSED MOTOR SWITCH OR CIRCUIT
BREAKER CAPABLE OF BEING LOCKED IN THE OPEN POSITION. PROVIDE SHUNT TRIP
FOR FIREALARM CONNECTION AND ELEVATOR SHUTDOWN REQUIREMENTS.
LOCK-OPEN DISCONNECT SWITCH FOR ELEVATOR CAR LIGHTS, RECEPTACLE AND
VENTILATION PER NEC 620-53.
LOCATE A MINIMUM OF 24" AWAY FROM BUILDING FOUNDATION.
POWER FOR SUMP PUMP VIA CONTROL PANEL THAT IS CORD AND PLUG TO
RECEPTACLE LOCATED IN ROOM, JANITOR 100C.
LIGHTNING PROTECTION DOWN CONDUCTOR. SEE SHEET E-113 FOR CONTINUATION.
MAGNETIC DOOR HOLDER 120V POWER CONNECTION. REFERENCE FA-113, NOTE 14.
120VAC POWER CONNECTION TO IDS/ACCESS CONTROL SYSTEM, THIS FLOOR.
COORDINATE WITH SECURITY/IDS INSTALLER PRIOR TO ROUGH-IN.
EMERGENCY SHUT-DOWN SWITCH FOR ELEVATOR BY ELEVATOR INSTALLER LOCATED
IN ELEVATOR PIT.
PROVIDE A DEDICATED 30A, 208V/1 PH CIRCUIT FOR EACH NEMA 30R TO SERVE UPS IN
THE STORAGE ROOM 101C. PROVIDE 3/4"C WITH 3#10 CONDUCTORS.
LOCATE IN COMM CABINET. SEE TELCOMM DRAWINGS.
CONTROLS FOR WINDOW SHADE SHALL BE INTEGRATED WITH LIGHTING DIMMING
CONTROL SYSTEM. SEE E-109 FOR DIMMING CONTROL LOCATION.
GARBAGE DISPOSAL SWITCH. COORDINATE WITH MECHANICAL FOR REQUIREMENTS.
KEY NOTES:
2 2
COORDINATE WITH INTERIOR PLAN DRAWING
FOR EXACT LOCATION OF FLOOR BOXES, PRIOR
TO ROUGH WORK.
BACK TO BACK MOUNTING OF BOXES SHALL
NOT BE PERMITTED IN THE SAME STUD CAVITY.
OFFSET PLACEMENT OF SWITCHES, POWER
AND COMMUNICATIONS SYSTEMS WITH STUD
LOCATION.
ALL UNDERGROUND GROUNDING CONNECTIONS
SHALL BE EXOTHERMALLY WELDED.
GENERAL NOTES:
1.
TYP
TYP
6 TYP
2.
2 2
3.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
226 284