Global Lightning Data Draft Performance Work Statement
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment_1_PWS_for_GLD_Rev_0.1.pdf | ||
| FA4600-15-R-0022_Global_Lightning_Data.pdf | ||
| Attachment_2_Vendor_Technical_Specification_Tables.docx | DOCX document | |
| Attachment_3_QASP.pdf | ||
| FA4600-15-R-0022_Draft_52.212-1(Updated).pdf | ||
| FA4600-15-R-0022_Draft_52_212-2_(Updated).pdf | ||
| Global_Lightning_Data_PWS_Rev_0.1t_(24_Aug_16).pdf | ||
| FA4600-15-R-0022_Draft_52.212-1(Updated).pdf | ||
| FA4600-15-R-0022_Draft_52_212-2.pdf | ||
| Global_Lightning_Data_PWS_Rev_0.1t_(24_Aug_16).pdf | ||
| Global_Lightning_Data_PWS_Rev_0_0_(17_Jun_16)_updated_22_Jun_16.pdf | ||
| Attachment_3_Vendor_Technical_Specification_Tables.pdf | ||
| FA4600-15-R-0022_Draft_52_212-2.pdf | ||
| FA4600-15-R-0022_Draft_52.212-1.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Performance Work Statement
Global Lightning Data
23 April 2015
1.0 Description of requirement. Air Force Weather Agency (AFWA), Offutt Air
Force Base, Nebraska requires delivery of global lightning observation data.
2.0 Scope of Requirement. AFWA has the following requirements for streaming lightning data:
2.0.1 Cloud to Ground (CG) and Cloud to Cloud (CF) lightning data. The United States
Air Force has a base requirement for global lightning data that includes 26 zones (see
Table 1).
2.0.2 AFWA requires that the vendor’s lightning detection network operate and transmit data to AFWA 24 hours a day, seven days a week. Any failure of either the detection network or of the vendor’s communication system that results in a loss of availability is defined as a system outage. Network availability is required to be at 98% or better in each zone.
2.0.3 AFWA requires that the vendor provide uninterrupted data flow, communications and data distribution.
2.0.4 AFWA requires the vendor to verify that lightning data it provides to the United
States Air Force meets AF lightning data technical requirements.
2.0.5 AFWA requires the ability to freely distribute government-generated products that contain lightning data to any participating Federal agency, contractors supporting the agency on an active contract, and to cooperating state and local government agencies at no additional cost, as long as the vendor's raw data is not available to unauthorized users.
2.0.5.1 Authorized users of lightning data products means any person or organization that the government has authorized to receive the products, to include Air Force Weather Agency, the Air Force, other military agencies (for example, US Navy, US Army), US Government (for example, US Geological
Survey, Dept of Homeland Defense), other foreign government's agencies (for example, UK meteorological organizations), research facilities to whom AFWA provides data, and contractors working on behalf of AFWA.
2.0.5.2 These products will be distributed in a secure manner to prevent unauthorized access and will not be released outside of the authorized users specified in paragraph 2.0.5.1. Lightning data products derived from the vendor's raw data will not allow the user community to view the raw data on which the product is based (ex. AFWA's AFW-WEBS/JAAWIN will display where the lightning strike is located on a map, but anyone viewing that map will not be able to interrogate the plot point for the raw data used to make the map display).
2.0.6 AFWA requires the ability to distribute raw lightning data to authorized users for the purposes of product creation and data archival. Authorized users of raw lightning data include Air Force Operational Weather Squadrons (OWS) and Weather Squadrons
(WS). The data will be distributed in a secure manner to prevent unauthorized access and the data will not be released outside of the OWSs and WSs. OWS and WS created data products derived from the vendor's raw data will not allow the user community to view the raw data on which the product is based (see 2.0.5.2). The 14th WS will not distribute archived raw lightning data to anyone other than the HQ AFWA user community.
3.0 Delivery Requirements (CDRLS)
3.0.1 The Contractor shall deliver the lightning data in a streaming ASCII text or XML format.
3.0.2 Data Stream.
3.0.2.1 The data stream shall include date-time (UTC) to thousands of a second, latitude (deg) and longitude (deg) (to thousandths), signal strength (ka), polarity, multiplicity (#strokes/flash), and the number of sensors used to collect the data.
3.0.2.2 The data stream shall be provided in Stroke format.
3.0.2.3 The data stream shall be flowing within 30 days of contract award. This provides the vendor with a transition period to get set up to deliver the data to
AFWA.
3.0.3 The data shall be encrypted as it is transmitted to prevent unauthorized receivers from using the data.
3.0.4 The data shall be delivered to AFWA through the internet as the primary transmission method.
3.0.5 The data shall be delivered to AFWA in four data feeds as follows: production primary, production backup, development primary, development backup.
3.0.6 The data shall be delivered to AFWA 24 hours a day, seven days a week. The
Contractor shall notify AFWA when the data flow has been compromised (ex. sensors are down causing gaps in the data, network issues that prevent the delivery of data, etc).
3.0.7 Outages
3.0.7.1 Network availability shall be 98% or higher in each month of the period of performance. The network shall be down no more than 12 hours in any month. The calculations used are based on an average 28 day month and are listed below.
28 days/mon * 24 hours/day = 672 hours/month.
660 hours network up / 672 hours/mo = 98% uptime
672 hours/mo – 660 hours uptime = 12 hours downtime/month.
3.0.7.2 Data availability shall be 98% or higher in each month of the period of performance for each data zone. The data shall be unavailable no more than 12 hours in any month for any data zone. The calculations used are based on an average 28 day month and are listed below.
28 days/mon * 24 hours/day = 672 hours/month.
660 hours data flowing / 672 hours/mo = 98% uptime
672 hours/mo – 660 data flowing = 12 hours data unavailable/month.
Data availability is only affected if there are not enough sensors to cover a given zone. Having one sensor unable to provide data in a given zone will not have an impact, if there are other sensors that adequately cover the zone and provide the data for that zone.
3.0.8 Help Desk
The contractor shall provide troubleshooting/technical support for the global lightning data feeds. The Help Desk shall field service requests from operational squadrons made through the Customer Support Center (CSC) located at Offutt Air Force Base. The Help
Desk shall respond to all service calls 365 days a year, 7 days a week, 24 hours a day and shall make an initial response to all service requests within ten (10) hours of receiving the service call from the CSC. The number of in-bound calls made for technical assistance will be unlimited.
4.0 Government Furnished Equipment and Information (GFE/GFI)
4.0.1 Government furnished equipment and information shall not be provided.
4.0.2 Contractor performance will take place at contractor facility.
5.0 Services Summary
PERFORMANCE
OBJECTIVE
PWS REFERENCE PERFORMANCE STANDARD
Data Delivery Format 3.0.1 Streaming ASCII text or XML format
Data Stream Elements 3.0.2 Required data elements in the data stream.
Data Stream Delivery Type 3.0.2 Required Stroke data.
Encryption 3.0.3 Required for all data feeds.
Table 1. Geographic Zones for Lightning Coverage.
Zones 1-15 are defined as all land area and the adjacent marine areas around the land area within each zone. Zones 16-26 are defined as the marine area within each zone. There is very little land, aside from some small islands in these zones. See Appendix A for maps of each zone.
ZONE
AREA
Zone 1A
Zone 1B
Zone 2
Zone 3
Zone 4
Zone 5
48 Contiguous States and the Virgin Islands
Puerto Rico
Alaska
Hawaii
Canada
Mexico
Zone 6
Zone 7
Zone 8
Zone 9
Zone 10
Central and South America
Europe
Northern Asia
Southern Asia
Middle East
Zone 11
Zone 12
Zone 13
Zone 14
Zone 15
Africa
East Indies and the Philippines
Australia and New Zealand
Greenland and Iceland
Antarctica
Zone 16
Zone 17
Gulf of Mexico, Caribbean Sea and West Indies
North Atlantic Ocean
Data Delivery Method 3.0.4 Provide data via the internet for all feeds.
Multiple Data Feeds 3.0.5 Provide four data feeds
24/7 Data 3.0.6 Provide the minimum data requirements specified in tables three thru five on a 24/7 basis
Service Issues 3.0.6 Provide notification of issues causing the data feed to be compromised.
Network Availability 3.0.7 Network uptime: 98%
Data Availability by Zone 3.0.7 Data Availability: 98%
Help Desk 3.0.8 Customer Complaint
Customer Feedback
Zone 18
Zone 19
Zone 20
South Atlantic Ocean
Mediterranean and Black Seas
Northeast Pacific Ocean
Zone 21
Zone 22
Zone 23
Zone 24
Zone 25
Northwest Pacific Ocean
Southeast Pacific Ocean
Southwest Pacific Ocean
Indian Ocean
Arctic Ocean
Zone 26
Southern Ocean
Table 2. Minimum Technical Specifications for CG Lightning LA, TA, Data Delivery Time, Probability of Detection (DE), False
Detection, and False Flash Type Id by Geographic Zone.
Zone Horizontal
Location Accuracy
Timing
Accuracy
Data Delivery Time Probability of Detection Probability of False
Detection
Probability of False
Flash Type
Id Zone 1A 500 meters or better for 90% of the area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be one
(1) minute or less for 99% of all flashes
90% or more of all flashes within the zone shall be reported
No more than 1%
No more than 1%
Zone 1B 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be two
(2) minutes or less for 99% of all flashes
70% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 2 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be two
(2) minutes or less for 99% of all flashes
70% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 3 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be two
(2) minutes or less for 99% of all flashes
70% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 4 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be two
(2) minutes or less for 99% of all flashes
70% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 5 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be three
(3) minutes or less for 99% of
70% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5% all flashes
Zone 6 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be two
(2) minutes or less for 99% of all flashes
70% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 7 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be two
(2) minutes or less for 99% of all flashes
70% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 8 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be two
(2) minutes or less for 99% of all flashes
70% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 9 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be three
(3) minutes or less for 99% of all flashes
70% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 10 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be two
(2) minutes or less for 99% of all flashes
70% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 11 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be three
(3) minutes or less for 99% of all flashes
70% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 12 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be three
(3) minutes or less for 99% of all flashes
70% or more of all flashes within the zone shall be reported
No more than 1%
Zone 13 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be three
(3) minutes or less for 99% of all flashes
50% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 14 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be three
(3) minutes or less for 99% of all flashes
70% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 15 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be three
(3) minutes or less for 99% of all flashes
10% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 16 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be three
(3) minutes or less for 99% of all flashes
70% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 17 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be three
(3) minutes or less for 99% of all flashes
70% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 18 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be three
(3) minutes or less for 99% of all flashes
50% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 19 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be three
(3) minutes or less for 99% of all flashes
70% or more of all flashes within the zone shall be reported
No more than 1%
No more
Zone 20 10 km or better for 0.001 seconds Total time from the time the 50% or more of all flashes No more No more
70% of the land area within the zone or better flash occurs to the time that flash is reported shall be three
(3) minutes or less for 99% of all flashes within the zone shall be reported than 1% than 5%
Zone 21 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be three
(3) minutes or less for 99% of all flashes
70% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 22 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be three
(3) minutes or less for 99% of all flashes
50% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 23 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be three
(3) minutes or less for 99% of all flashes
50% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 24 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be three
(3) minutes or less for 99% of all flashes
50% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 25 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be three
(3) minutes or less for 99% of all flashes
70% or more of all flashes within the zone shall be reported
No more than 1%
No more than 5%
Zone 26 10 km or better for
70% of the land area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be three
(3) minutes or less for 99% of all flashes
10% or more of all flashes within the zone shall be reported
No more than 1%
Table 3. Minimum Technical Specifications for Lightning Polarity, Estimated Peak Current, and Strokes/Flash by Geographic
Zone for CG.
Zones 1-26
Polarity Report for all CG flashes
Estimated Peak
Current
Report for all CG flashes
Strokes per Flash Report for all CG flashes
Table 4. Minimum Technical Specifications for Cloud Flash (CF) Data by Location.
Location Horizontal
Location
Accuracy
Timing
Accuracy
Data Delivery
Time
Probability of
Detection
Probability of False
Detection Zone 1A 10 km or better for
90% of the area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be one (1) minute or less for 99% of all flashes
15% or more of all flashes within the zone shall be reported
No more than 1%
Zones 1B –
10 km or better for
70% of the area within the zone
0.001 seconds or better
Total time from the time the flash occurs to the time that flash is reported shall be three (3) minutes or less for 99% of all flashes
10% or more of all flashes within the zone shall be reported than 1%
Appendix A: Coverage Area Maps by zone from Federal Lightning Data Requirements (FCM-
R27-2008)