Attachment_5_Appendix_D__AVB_Monthly_Inspection_Log.pdf

PDF 61 KB Posted

Attached to
Active Vehicle Barriers Maintenance and Repair Federal contract opportunity
Solicitation number
FA4460-17-T-0004
Issued by
Department of the Air Force Air Mobility Command

About this file

Attached is Appendix D, Inspection Log

View the file

Other files for this federal contract opportunity

Other files attached to Active Vehicle Barriers Maintenance and Repair, newest first.
File Type Posted
Attachment_2_Appendix_A_Definitions_and_Acronymns.pdf PDF
Attachment_1_Performance_Work_Statement.pdf PDF
Attachment_6_Appendix_E_Service_Request_Authorization_Form.pdf PDF
Attachment_4_Appendix_C_Barrier_Equipment_List.pdf PDF
Attachment_3_Appendix_B_References.pdf PDF
FA4460-17-T-0004_-_Barriers_Solicitation.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DATE TIME DATE TIME

SIGN

PRINT

NO Sat UnSat

REMARKS

Remarks

Remarks

Remarks

Remarks

Remarks

Remarks

Remarks

Remarks

Remarks

INBOUND

LANE REOPEN

SCHEDULE

OUTBOUND

INBOUND

001 CHECK WITH COR FOR ANY DEFICIENCIES REPORTED BY SECURITY FORCES

CHECK SPACE HEATER FOR PROPER OPERATION007

006 CHECK HYDRAULIC FLUID LEVEL

008 CHECK BATTERY CELLS & VOLTAGE AND DETERMINE CONDITION

CHECK BYPASS VALVE POSTIONS ENSURE IN CORRECTION POSTION FOR NORMAL OPERATIONS

MONTHLY VA Net 300 Inspection Log

Corrective Action if UnSatACTION

LOCATION:__________________

COR APPROVAL

LANE CLOSURE

SCHEDULE

OUTBOUND

INSPECT ALL IND LIGHTS AND TRAFFIC LIGHTS FOR PROPER OPERATION, RPL BULBS AS NECESSARY

CHECK STATIC HYDRAULIC PRESSURE

INSPECT AREA FOR LEAKS

010 CLEAN INSIDE OF BARRIER

CHECK MANUAL HYDRAULIC PUMPS ARE IN CORRECT POSISTION FOR NORMAL OPERATIONS

REMARKS

REMARKS

REMARKS

REMARKS

REMARKS

REMARKS

REMARKS

REMARKS

REMARKS

REMARKS

REMARKS

REMARKS

MONITOR BATTERY VOLTAGE DURING REWIND OPERATIONS ANNOTATE ON THIS BARRIER FORM

REPAIR, TIGHTEN, OR REPLACE BOLTS OR PARTS

GREASE FITTINGS ON ACTUATORS FOR TRAP AND OIL TRAP LID HINGES

INSPECT OUTSIDE PLATES FOR DAMAGE

INSPECT NET FOR VISIBLE SIGNS OF DAMAGE

CHECK FIRE EXTINGUISHER CONDITON AND SERVICEABILITY

CLOSE LANES

INSPECT CONTROL CABINET FOR VISIBLE SIGNS OF DAMAGE

CHECK FOR PROPER OPERATION, AT GUARD SHACK CONTROL PANEL TO CLEAR ANY ANIMALS

IN SYSTEM

PLACE MAINTENANCE CONTROL PANEL IN 'LOCAL' CONTROL MODE

CYCLE TRAP LID SYSTEM UP BUTTON AND VALVE OFF AFTER COMPLETELY OPEN

LOCK AND TAG OUT VALVE HANDLE TO TRAP HYDRAULIC SYSTEM

CYCLE NET BUTTON TO DEPLOY NET TO UP POSITION

LOCK AND TAG OUT VALVE HANDLE TO NET HYDRAULIC SYSTEM

REMARKS

REMARKS

REMARKS

REMARKS

REMARKS

REMARKS

REMARKS

REMARKS

ADDITIONAL COMMENTS:

Inspector:

(Sign & Print) Date:

PERFORM CORROSION CONTROL AS NEEDED

ADJUST BARRIER NET SPACERS

CHECK STATIC HYDRAULIC PRESSURE

CLEAN BARRIER PITS OF DEBRIS

030 LOWER NET BACK INTO TRAP AND CLOSE TRAP LID

CYCLE BARRIER TO ROAD OPEN POSISTION AND PUT MAINTENANCE CONTROL IN EFO

MODE

029 REMOVE TAF OUT AND RESTORE BOTH VALVES TO OPEN POSISTION

032 CHECK STATIC ACCUMULATOR PRESSURE AND ADD NITROGEN GAS 1400 PSI (+/ 50 PSI)

033 REOPEN LANES AND RETURN TRAFFIC FLOW TO NORMAL

File details come from the government source that posted it. Updated .