Attch_2_-_Drawings_20190130.pdf

PDF 9 MB Posted

Attached to
Repair Command Post Bldg 90208 Federal contract opportunity
Solicitation number
FA441719RA013
Issued by
Department of the Air Force Special Operations Command

View the file

Other files for this federal contract opportunity

Show all 17

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P O

O L

P O

O L

P O

O L

P O

O L

P O

O L

MARY ESTHER, FLORIDA

91065

90527

9915799156

31022

31022

90639

91006

91158

9113191129

99901 99902

90395 90080

90050

91362

99147

9053590535

90535

90209

90108

90580

90581

91404

99326

90727

90800

90536

90534

91157

91107

91168

90306

90905

90917

99958

91059

91058

90086

90311

90500

90611

90730

30041

90083

90356

90364

99103

90524

99121

90626

90749

90757

90813

91041

91263

91264

92478 92479

90351

90363

90360

90512 90513

90513

90512

29077

29077

91043

91038

90005

90734

90581

90534

29073

29073

90396 90396

29075

29075

29075

29075

91124

91149

93605

90379

90380

90507

91101

90506

92547

90628

99154

99077

90021

90503

91537

92557

90209

92540

90038

90427

90412

90502

99009

93576

90710

91141

93318

99005

92418

91625

90221

90228

99049

90612

90065

90365

90349

92536

93357

92509

92485

90059

90067

91262

91259

92500

93405

92031

92078

92075

90020

90028

90421

90206

90630

91113

91258

93701

90332

91042

91136

90060

92077

90010

91126

90708

90812

91302

92564

93621

90113

93333

93332

92439

90700

90758

92531

93346

92276

92108

90002

92552

91153

92542

91041

90353

90640

90501

93530

92049

93565

90718

92066

92507

90322

91250

90603

90231

92408

92465

90829

91049

90135

92096

92442

91013

93454

90712

92463

92101

90420

99065

93626

90519

92073

92003 92002

92020

90029

91257

92018

90055

92467

93464

92402

90323

90407

90367

90050

90551

92086

90220

90310

90755

90034

91144

92468

90816

99141

92440

92525

91021

90423 91028

90057

90061

90066

90638

90553

91260

93437

90625

92517

90624

91036

92508

92459

93413

91268

92074

92106

92104 92041

92053

92056

92070

92524

92535

92506 92543

92097

92067

90404

90720

90632

92045

90203

91114

91119

91538

93640

90838

99098

91033

92401

91000

90079

92444

90331

92511

90517

90705

92092

90117

92530

92445

91147

90373

93549

93301

92545

93461

92523

91515

91024

91027

92433

92518

91361

92473

99031

92521

90140

90402

93476

92544

93429

92063

92088

91370

90518

90036

91020

92062

99126

91351

90535

99019

92562

99158

91365

91603

91025

90926

93432

91601

91120

92466

90505

91035

93421

90074

90073

90039

93637

93389

92539

92036

92012

90213

92044

91500

99117

91266

92428

92460

93566

91310

91135

91106

90329

92503

90109

90763

90714

93541

99010

90361

92047

90810

90627

90823

92514

93325

92555

92083

90742

93349

91164

91052

90368

92095

99137

92533

92038

93398

90833

90081

91325

91360

91007

90743

90811

91156

90916

92079

92425

92400

92015

92407

91099

92527

90601

93510

93309

90355

92054

90070

90111

90357

90023

92471

92441

90102

93304

93317

93354

90911

91145

90076

92556

91152

91030

91132

91034

92033

92450

92502

99146

99018

99094

90729

91057 92103

90387

90381

91161

92515

92446

92025

92464

90951

91162

90052

92529

93501

92014

90134

90613

92537

93493

93629

90362

99004

90141

93517

90037

92064

90392

90629

93397

90069

90068

99041

91510

99057

90388

92424

91112

91133

92094

90711

92048

93368

93485

90577

90075

90340

99016

99014

99020

99048

99090

99104

90607

92541

92516

99150

99535

92501

92463

92419 92426

91154

92089

90747

90522

93538

92505

99058

92023

91032

92034

99067

91546

90210

92005

99024

99025

99051 99127

99719 99718 99717

99716

99023

90609

90085

92461

92009

90511

92434

93445

93608

91122

90724

92051

92008

92001

92549

90626

92435

93453

90327

93645

92548

90701

92553

93365

91330

90809

92437

91105

93596

90580

93650

93444

91103

93586

91104

92087

92522

90207

99115

92100

92004

90827

93500

90320

93556

90333

91053

90058

92058

92068

92071

92076

92072

92010

92055 90056

93486

93373

90817

90230

91146

93522

92026 92027

92040

90377

90054

90642

90223

90001

93581

91012

92022

90378

92451

93573

92452

90606

91155

92436

91054

90145

90717

92030 92032

90372

90731

90328

92069

92024

90084

90005

93509

92455

92528

90703

92000

92013

91252

91055

99043

90802

91037

92011

91140

91023

91151

92430

90759

92420

92275

90610

90801

91031

90121

92039

92432

90015

91009

91039

90635

99068

90928

90616

90105

92406

93477

90615

92035

92052

90707

90229

93613

90375

90760

90049

92082 92061

92538

90337

91130

91363

91350

91050

90334

92050

92090

93381 93341

90950

99162

99001

90131

99060

90552

91016

99105

99007

99083

99055

99056

90390

99044

99126

99145

99022

90825

90358

92098

90347

91163

92102

90008

91300

90339

92105

90621

99059

92099

99116

90048

92084

92546

90374

90300

91142

92107

92016 92017

90419

92551

92037

9204392042

92057

92513

91137

92059

90617

93653

92080

90215

90382

92404

90232

93386

90302

93414

99142

92091

90521

93557

91520

91255

90702

90033

92438

93597

90935

92065

93422

90369

90532

90619

90035

90208

90618

90128

90822

90748

92472

90137

93469

90371

93618

9102990352

92060

90138

90063

90806

90525

91047

92021 92019

92028

90326

93589

90713

92403

90064

90370

90115

92519

92449

90426

90062

90636

91045

99030

90531

90051

91254

90304

99500

91056

90366

91364

92429

99042

91303

91148

92093

90880

91301

90815

99118

99029

99061

90225

92046

90053

91265

92085

90030

91400

92550

90716

92427

93542

91159

90359

92469

90032

90106

90637

90325

91307

99045

91048

90761

90101

92081

92431

90600

93660

9200792006

90308

90043

92470

90918

Tully Street

Kissam Street

M A

Y S

T R

E E

T

Downs R oad

W alkup W ay

M artin

Luth er K ing

Downs Road

Kanuha D riv e

Blessinger D riv e

Bartley Street

Mitchell Road

Independence Road

T e rr y

A ve nu e

McClean Stre et

Harts on S tre et

US98

Tully Street

M a in te n a nc e H a ul

R o a

US98

Howie Walters Way

Lielmanis Avenue

US98

K e rw o o d R o a d

C od y A ve nu e

Lukasik Avenue

Tully Street

R ed

H or se R oa d

H am by Place

Westfall C ircl e

Bedel Street

T u lly S tr e e t

T u lly S tree t

Bennett A venue

C ru z A ve n u e

Red Horse Road

C ru z A ve n u e

Frazier Street

B e n n e tt A v e n u e

Bedel Street

Independence R oad

W alkup W ay

Corlew Road

McMillan Street

US98

W e av e r A ve nu e

Schmauss Lane

Hume Drive

Clark Road

Gelshlager Street

Whitbeck Street

C am p a ig n e

S tr e e t Purcell Drive

C o d y A ve n u e

US98

Independence Road

O 'N e il

A ve n u e

US98

McIntosh Court

Hume Drive

Harrison Drive

Acha Drive

H u m e D ri ve

Walters Drive

Hodges Street

Lewis Drive

Hume Drive

Galvan Street

Bland Street

Hume Drive

Grimm Lane unk unk

Tully Street

Red H ors e R oad

Bakke Street

M a yo S tr ee t

Bakke Street

Tupelo Circle

Red Horse Road

S im pson A venue

Tully Street

F o xx A ve nu e

L e to u rn e au

C ir cl e

L e t o u rn e a u

C ir cle

HURLBURT MAIN GATE

(NO COMMERCIAL ENTRY)

BUILDING 90905

FIRE DEPARTMENT

BLDG. 90734

MARTIN LUTHER KING JR.

BLVD INTERSECTION

ENTRANCE

PASS AND ID OFFICE

COMMERCIAL VEHICLE

INSPECTION ENTRANCE

HURLBURT EAST GATE (NO

COMMERCIAL ENTRANCE)

CONTRACTOR

HAUL ROUTE

BARTLEY STREET

T E

R R

Y A

V E

N U

E

90208

CONTRACTOR

STAGING AREA

IA

R

E

OF

RC

SP

EC

IA

AN

N

P

ER

L O

AT

IO

M M

S

CO

D

SHEET REFERENCE:

D A

T E

SHEET NUMBER:

OF

D E

S C

R

IP

T

IO

N R

E V

A

IR

F O

R C

E

SP

EC

IA

L O

PE

R

A

TI

O N

S C

O M

M A

N D

SP

EC

IA

L O

PE

R

A

TI

O N

S C

IV

IL

E N

G

IN

EE

R

S Q

U A

D R

O N

H U

R

LB

U R

T

FI

E

LD

, F

LO

R

ID

A

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90208

G-001

100% DESIGN SUBMITTAL

01/30/2019

T

IT

LE

S

H E

E T

JGH

RCR

CP1026752

R E

P A

IR

C

O M

M A

N D

P O

S T

S

O A

O S

B

U

IL

D

IN

G

BASE MAP

REPAIR COMMAND POST 1 SOAOS, BLDG. 90208

HURLBURT FIELD, FLORIDA

CP1026752

PROJECT SITE

INDEX OF DRAWINGS

NUMBER SHEET NAME

GENERAL

G-001 TITLE SHEET

STRUCTURAL

S-101 GENERAL NOTES

S-102 PARTIAL DEMOLITION PLAN

ARCHITECTURAL

A-001 LEGENDS, NOTES AND ABBREVIATIONS

A-110 FLOOR PLAN - EXISTING

A-111 FLOOR PLAN - DEMOLITION

A-112 FLOOR PLAN - NEW WORK

A-150 CEILING PLAN - EXISTING

A-151 CEILING PLAN - DEMOLITION

A-152 CEILING PLAN - NEW WORK

A-501 DETAILS

A-601 OPENING SCHEDULE AND DETAILS

A-602 OPENING DETAILS

A-603 OPERABLE PARTITION DETAILS

INTERIOR

I-120 FINISH PLAN, SCHEDULE AND DETAILS

I-121 FLOOR PLAN - GFGI FURNITURE

FIRE PROTECTION

F-001 GENERAL FIRE PROTECTION INFORMATION

F-101 DEMOLITION PLAN - FIRE PROTECTION

F-201 FIRST FLOOR PLAN - FIRE PROTECTION

FIRE ALARM

FA-001 FIRE ALARM LEGEND AND GENERAL NOTES

FA-002 FIRE ALARM DETAILS

FA-100 FIRE ALARM DEMOLITION PLAN

FA-200 FIRE ALARM NEW WORK PLAN

MECHANICAL

M-001 GENERAL MECHANICAL INFORMATION

M-101 DEMOLITION PLAN - HVAC

M-201 FIRST FLOOR PLAN - HVAC

M-501 MECHANICAL DETAILS

M-502 MECHANICAL DETAILS

M-601 MECHANICAL SCHEDULES

M-701 MECHANICAL CONTROLS

ELECTRICAL

E-001 LEGEND AND GENERAL NOTES

E-002 LIGHTING FIXTURE DETAILS AND SCHEDULE

E-100 ELECTRICAL DEMOLITION PLAN

E-200 NEW WORK POWER PLAN

E-201 NEW WORK MECHANICAL POWER PLAN

E-300 NEW WORK LIGHTING PLAN

E-400 PANEL SCHEDULES

E-401 PANEL SCHEDULES

E-402 PANEL SCHEDULES

TELECOMMUNICATIONS

T-001 TELECOM LEGEND AND ABBREVIATIONS

T-002 TELECOM NOTES

T-100 TELECOM DEMOLITION PLAN

T-110 TELECOM FLOOR PLAN

T-111 ENLARGED TELECOM FLOOR PLANS

T-201 TELECOM DETAILS

T-202 TELECOM DETAILS

T-301 TELECOM SINGLE LINE DIAGRAMS

T-401 TELECOM ENLARGED PLANS

NORTH

NORTH

AR94997

DERETSI

G

E R

A R C H

IT

E C

T

FOETAT

S

FL O R ID

A

RIC

E

ACREBO

R

RLT

01/30/19

1.00 GENERAL NOTES

1.01 DRAWINGS SHOW TYPICAL AND CERTAIN SPECIFIC CONDITIONS ONLY. FOR DETAILS NOT SPECIFICALLY SHOWN, PROVIDE DETAILS SIMILAR TO THOSE SHOWN.

1.02 VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS BEFORE STARTING WORK. NOTIFY STRUCTURAL

ENGINEER OF ANY DISCREPANCY.

1.03 THE DESIGN, ADEQUACY, AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC., ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. TAKE NECESSARY PRECAUTIONS TO PROTECT THE EXISTING STRUCTURE AND ITS FOUNDATION AND TO LIMIT, TO THE EXTENT POSSIBLE, THE EFFECTS OF CONSTRUCTION THAT THE NEW STRUCTURE HAS ON

THE EXISTING STRUCTURE.

1.04 COORDINATE STRUCTURAL CONTRACT DOCUMENTS WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND CIVIL. NOTIFY STRUCTURAL ENGINEER OF ANY CONFLICT AND/OR OMISSION. CONTRACTOR SHALL MAKE NO DEVIATION FROM DESIGN DRAWINGS WITHOUT WRITTEN APPROVAL OF THE ARCHITECT. FOR ADDITIONAL OPENINGS NOT SHOWN ON THE

STRUCTURAL DRAWINGS, SEE ARCHITECTURAL, MECHANICAL, AND PLUMBING DRAWINGS.

1.05 DESIGN CRITERIA: THE STRUCTURE HAS BEEN DESIGNED UTILIZING THE FOLLOWING REFERENCES:

A. UFC 1-200-01, GENERAL BUILDING REQUIREMENTS

B. UFC 3-301-01, STRUCTURAL ENGINEERING, WITH CHANGE 1

C. UFC 3-310-04, SEISMIC DESIGN FOR BUILDINGS WITH CHANGE 1

D. UFC 4-010-01, DOD MINIMUM ANTITERRORISM STANDARD FOR BUILDINGS, INCLUDING CHANGE 1

E. INTERNATIONAL BUILDING CODE, 2015

F. UFC 4-023-03, DESIGN OF BUILDINGS TO RESIST PROGRESSIVE COLLAPSE WITH CHANGE 1

G. ASCE 7-10, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES

H. ACI 302.1 R-04, CONCRETE FLOOR AND SLAB CONSTRUCTION

I. ACI 318-14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE

J. ACI 360 R-10, DESIGN OF SLABS-ON-GROUND

K. AISC STEEL CONSTRUCTION MANUAL 14TH EDITION

L. TMS 402/602-16, BUILDING CODE REQUIREMENTS AND SPECIFICATION FOR MASONRY STRUCTURES (ACI 530)

M. APPLICABLE STEEL DECK AND JOIST INSTITUE GUIDES AND SPECIFICATIONS

1.06 DESIGN LOADS:

A. DEAD LOADS:

1. MECHANICAL, ELECTRICAL, PLUMBING: 5 PSF

2. CEILINGS AND INSULATION: 5 PSF

3. ROOFING MEMBRANE: 5 PSF

B. LIVE LOADS: (MAY BE REDUCED PER CODE)

1. STAIRS: 100 PSF

2. CORRIDORS: 100 PSF

3. OFFICE BLDG - OFFICES: 50 PSF

4. PARTITIONS: 15 PSF (NOT REQUIRED WITH LIVE LOADS EXCEEDING 80 PSF)

5. ROOFS: 20 PSF

6. SLAB-ON-GRADE: 100 PSF

C. WIND LOADS - STRUCTURE HAS BEEN DESIGNED TO CONFORM TO THE WIND PROVISIONS OF ASCE 7-10. SEE WIND

PRESSURE DIAGRAM & CHART ON S102 FOR DESIGN ASSUMPTIONS.

D. EARTHQUAKE LOADS:

1. SEISMIC IMPORTANCE FACTOR (Ie): 1.5

2. OCCUPANCY CATEGORY: IV

3. SEISMIC DESIGN CATEGORY: C

4. MAPPED SPECTRAL RESPONSE ACCELERATIONS & PARAMETERS

Ss = 0.08g S1 = 0.05g

5. SITE CLASSIFICATION: D

6. BASIC SEISMIC-FORCE-RESISTING SYSTEM: MASONRY SHEAR WALLS

7. SEISMIC RESPONSE COEFFICIENT, Cs = 0.01

8. RESPONSE MODIFICATION FACTOR, R=3.5

9. ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL FORCE

REFER TO MEP DWGS FOR SEISMIC SUPPORT AND ATTACHMENT REQUIREMENTS FOR CERTAIN MEP COMPONENTS AS

PER THE IBC.

1.07 REVIEW OF SUBMITTALS AND/OR SHOP DRAWINGS BY THE STRUCTURAL ENGINEER DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO REVIEW AND CHECK SHOP DRAWINGS BEFORE SUBMITTAL TO THE STRUCTURAL ENGINEER. THE CONTRACTOR REMAINS SOLELY RESPONSIBLE FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF SHOP DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS, AND DIMENSIONS SPECIFIED IN THE CONTRACT DOCUMENTS. CONTRACTOR IS ALSO RESPONSIBLE FOR MEANS, METHODS, TECHNIQUES, SEQUENCES, AND

PROCEDURES OF CONSTRUCTION.

2.00 FOUNDATIONS AND SLAB-ON-GRADE

2.01 AT THIS TIME NO GEOTECHNICAL REPORT HAS BEEN SUBMITTED. AN ALLOWABLE SOIL BEARING PRESSURE HAS BEEN CONSERVATIVELY ESTIMATED BASED ON SIMILAR PROJECTS OF THIS SIZE AND LOCATED IN THE SAME GENERAL AREA OF CONSTRUCTION. A QUALIFIED GEOTECHNICAL ENGINEER SHALL CHECK COMPACTION OF THE FOOTINGS. THE SOILS IMMEDIATELY BENEATH ALL FOOTINGS SHOULD BE COMPACTED FOR A MINIMUM DEPTH OF 12 INCHES TO A MINIMUM OF 95% OF THE SOIL’S MAXIMUM DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST (ASTM D1557) USING A LARGE TAMPER.

2.02 SLAB-ON-GRADE REQUIREMENTS:

A. THE SLAB-ON-GRADE SHALL BE A MINIMUM OF 6 INCHES THICK, PLACED ON COMPACTED SUBGRADE, REINFORCED WITH #3 AT 12”.

B. PLACE CONTROL OR CONSTRUCTION JOINTS AT LOCATIONS INDICATED BY “C.J.” IF NOT INDICATED, LOCATED JOINTS AT COLUMN CENTERLINES AND AT 20’-0” O.C MAX. SAWCUT CONTROL JOINTS AS SOON AFTER POURING AS POSSIBLE, WHEN CONCRETE WILL NOT RAVEL; 12 HRS. MAX. CURE CONCRETE IN ACCORDANCE WITH ACI 301. BEGIN CURING IMMEDIATELY AFTER POURING TO LIMIT CRACKING PRIOR TO SAWCUTTING CONTROL JOINTS.

C. SUBGRADE SHALL BE PREPARED AS RECOMMENDED IN THE GEOTECHNICAL REPORT. IN THE ABSENCE OF A GEOTECHNICAL REPORT, PROVIDE TYPE D FILL, 8 INCHES THICK BELOW THE BOTTOM OF THE FLOOR SLABS AND FOOTINGS COMPACTED TO 100% OF THE MAXIMUM MODIFIED PROCTOR DENSITY. DENSITY TESTS SHALL BE TAKEN AT

1000 SF INTERVALS. SEE SPECIFICATIONS AND REPORT (IF AVAILABLE).

D. SEE SPECIFICATIONS FOR VAPOR RETARDER MATERIAL. VAPOR RETARDER SHALL CONFORM TO ASTM E1745, CLASS A, B, OR C. THE VAPOR RETARDER SHOULD BE PLACED OVER THE PREPARED SUBGRADE. TO REDUCE THE POSSIBILITY OF PUNCTURE WHEN THE VAPOR RETARDER IS TO BE PLACED OVER A ROUGH GRANULAR FILL LAYER, PROVIDE A THIN LAYER OF APPROXIMATELY 1/2 INCH OF FINE-GRADED MATERIAL ROLLED OR COMPACTED OVER THE GRANULAR FILL LAYER PRIOR TO INSTALLATION OF THE VAPOR RETARDER. VAPOR RETARDER SHOULD BE OVERLAPPED 8 IN. AND TAPED AT THE JOINTS AND CAREFULLY FITTED AROUND SERVICE OPENINGS.

3.00 REINFORCED CONCRETE

3.01 ALL CONCRETE WORK SHALL CONFORM TO ACI 301-16, SPECIFICATIONS FOR STRUCTURAL CONCRETE. DESIGN IS BASED ON ACI 318-14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE. DETAIL CONCRETE REINFORCEMENT AND ACCESSORIES IN ACCORDANCE WITH ACI 315R-18, GUIDE TO PRESENTING REINFORCING STEEL DESIGN DETAILS. DETAIL ALL CONCRETE WALLS AND BEAMS ON THE SHOP DRAWINGS IN ELEVATION UNLESS SPECIFICALLY APPROVED OTHERWISE.

SUBMIT SHOP DRAWINGS FOR APPROVAL, SHOWING ALL FABRICATION DIMENSIONS AND LOCATIONS FOR PLACING REINFORCING STEEL AND ACCESSORIES. DO NOT BEGIN FABRICATION UNTIL SHOP DRAWINGS ARE COMPLETED AND

REVIEWED.

3.02 UNLESS NOTED OTHERWISE, ALL CONCRETE SHALL BE NORMAL WEIGHT AND HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 4,000 PSI. ALL CONCRETE SHALL HAVE ENTRAINED AIR, U.N.O. CONCRETE MAY CONTAIN A PROPERLY DESIGNED

SUPERPLASTICIZER FOR WORKABILITY.

3.03 REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60 UNLESS NOTED OTHERWISE.

3.04 THE PROPOSED MATERIALS AND MIX DESIGN SHALL BE FULLY DOCUMENTED AND REVIEWED BY THE OWNER'S TESTING LABORATORY. RESPONSIBILITY FOR OBTAINING THE REQUIRED DESIGN STRENGTH IS THE CONTRACTOR'S.

3.05 USE OF CALCIUM CHLORIDE, CHLORIDE IONS, OR OTHER SALTS IN CONCRETE IS NOT PERMITTED.

3.06 HORIZONTAL CONSTRUCTION JOINTS ARE PERMITTED ONLY WHERE INDICATED. THE STRUCTURAL ENGINEER SHALL APPROVE THE LOCATION OF VERTICAL CONSTRUCTION JOINTS. CONSTRUCTION JOINTS SHALL BE THOROUGHLY ROUGHENED BY MECHANICAL MEANS, AND CLEANED. CONTRACTOR SHALL SUBMIT DRAWINGS SHOWING INTENDED POURING SEQUENCE AND LOCATION OF CONSTRUCTION JOINT TO THE ENGINEER FOR REVIEW. PROPOSED METHODS MUST BE ACCEPTABLE TO THE

ARCHITECT BEFORE USE.

3.07 PLACE VERTICAL CONTROL JOINTS IN CONCRETE WALLS AT 10'-0" O.C. (MAX), 3/4" DEEP, V-CHAMFERED ON BOTH FACES.

CONSTRUCTION JOINTS SHALL FALL ON CONTROL JOINTS AND SHALL BE KEYED. STOP 50 PERCENT OF THE SPECIFIED

LONGITUDINAL REINFORCEMENT AT THE CONTROL JOINT.

3.08 CHAMFER OR ROUND ALL EXPOSED CORNERS A MINIMUM OF 3/4".

3.09 TIE ALL REINFORCING STEEL AND EMBEDMENTS SECURELY IN PLACE PRIOR TO PLACING CONCRETE. PROVIDE SUFFICIENT SUPPORTS TO MAINTAIN THE POSITION OF REINFORCEMENT WITHIN SPECIFIED TOLERANCE DURING ALL

CONSTRUCTION ACTIVITIES. "STICKING” DOWELS INTO WET CONCRETE IS NOT PERMITTED.

3.10 PROVIDE CONTINUOUS REINFORCEMENT WHEREVER POSSIBLE; SPLICE ONLY AS SHOWN OR APPROVED; STAGGER SPLICE WHERE POSSIBLE; USE FULL TENSION SPLICE (CLASS "B") UNLESS NOTED OTHERWISE. DOWELS SHALL MATCH THE SIZE AND SPACING OF THE SPECIFIED REINFORCEMENT AND SHALL BE LAPPED WITH FULL TENSION SPLICES (CLASS "B")

UNLESS NOTED OTHERWISE. TERMINATE BARS WITH STANDARD HOOKS.

3.11 REINFORCING STEEL SHALL HAVE THE FOLLOWING CONCRETE COVER UNLESS NOTED OTHERWISE (PER ACI 318-14

TABLE 20.6.1.3.1):

A. FORMED CONCRETE EXPOSED TO THE EARTH OR WEATHER:

1. #6 THROUGH #18 BARS: 2"

2. #5 BARS AND SMALLER: 1-1/2"

B. CONCRETE NOT EXPOSED TO EARTH OR WEATHER:

1. SLABS AND WALLS: 3/4"

2. BEAMS (STIRRUPS) AND COLUMNS (TIES): 1-1/2"

3.12 THE DESIGN AND CONSTRUCTION OF FORMS - SEE FORM NOTES. SHORING SHALL REMAIN IN PLACE UNTIL CONCRETE

HAS ATTAINED 75% OF ITS 28-DAY STRENGTH.

3.13 THE LICENSED DESIGN PROFESSIONAL, A PERSON UNDER THE SUPERVISION OF A LICENSED DESIGN PROFESSIONAL, OR A QUALIFIED INSPECTOR SHALL VERIFY COMPLIANCE WITH CONSTRUCTION DOCUMENTS. (ACI 318-14 PAR. 26.13.1.3)

3.14 ALL REINFORCING STEEL PLACEMENTS SHALL BE REVIEWED BY THE CONTRACTING OFFICER, OR BY A REPRESENTATIVE

RESPONSIBLE TO HIM. (RE: ACI 318 PAR. 1.3.1)

4.00 MASONRY

4.01 CONCRETE MASONRY DESIGN, CONSTRUCTION AND TESTING SHALL CONFORM TO TMS 402/602-16, BUILDING CODE

REQUIREMENTS AND SPECIFICATION FOR MASONRY STRUCTURES.

4.02 PROVIDE NORMAL WEIGHT, HOLLOW, LOAD-BEARING CONCRETE MASONRY UNITS (CMU) CONFORMING TO ASTM C90, UNLESS NOTED OTHERWISE.

4.03 PROVIDE MASONRY CONSTRUCTION WITH MINIMUM COMPRESSIVE STRENGTH, f'm = 2,000 PSI.

4.04 PROVIDE TYPE "M" OR “S” MORTAR IN ACCORDANCE WITH ASTM C270 BY PROPORTION REQUIREMENTS, UNLESS NOTED

OTHERWISE.

4.05 VERTICAL CELLS SHALL BE REINFORCED WITH #5 AT 16" O.C. MINIMUM, UNLESS NOTED OTHERWISE (U.N.O.) IN THE CONTRACT DRAWINGS. VERTICAL REINFORCING SHALL BE CONTINUOUS (LAPPED 48 BAR DIAMETERS MINIMUM AT SPLICES, U.N.O.) AND HELD IN POSITION AT THE TOP AND BOTTOM OF THE GROUT POUR. U.N.O., POSITION VERTICAL REINFORCING IN

THE CENTER OF THE CELL.

4.06 PROVIDE GROUT FOR REINFORCED MASONRY IN ACCORDANCE WITH ASTM C476. GROUT SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3,000 PSI UNLESS NOTED OTHERWISE. GROUT SHALL BE FLUID CONSISTENCY. FLUID CONSISTENCY SHALL MEAN THAT CONSISTENCY AS FLUID AS POSSIBLE FOR POURING WITHOUT SEGREGATION OF THE CONSTITUENT PARTS. FILL ALL CELLS BELOW GRADE WITH GROUT. ALL GROUT SHALL BE CONSOLIDATED AT THE TIME OF POURING BY VIBRATING AND THEN RECONSOLIDATED BY AGAIN PUDDLING LATER, BEFORE PLASTICITY IS LOST. WHEN GROUTING IS STOPPED FOR ONE HOUR OR LONGER, CONSTRUCTION JOINTS SHALL BE FORMED BY STOPPING THE POUR OF

THE GROUT 1-1/2 INCHES BELOW THE TOP OF THE UPPERMOST UNIT.

4.07 PROVIDE HORIZONTAL JOINT REINFORCEMENT COMPLYING WITH ASTM A82, NO. 9 GAUGE OR HEAVIER, ZINC COATED, PLACED 16 INCHES ON CENTER UNLESS NOTED OTHERWISE.

4.08 PROVIDE RUNNING BONDS WITH VERTICAL JOINTS LOCATED AT CENTER OF MASONRY UNITS IN THE ALTERNATE

COURSE BELOW, UNLESS NOTED OTHERWISE.

4.09 ALL MASONRY UNITS SHALL BE FREE OF EXCESSIVE DUST AND DIRT AT THE TIME THEY ARE LAYED BY THE MASON.

4.10 ALL REINFORCED HOLLOW UNIT MASONRY SHALL BE BUILT TO PRESERVE THE UNOBSTRUCTED VERTICAL CONTINUITY OF THE CELLS TO BE FILLED. WALLS AND CROSS WEBS IN ALL REINFORCED MASONRY WALLS SHALL BE FULLY BEDDED IN MORTAR. ALL HEAD (OR END) JOINTS SHALL BE SOLIDLY FILLED WITH MORTAR FOR A DISTANCE IN FROM EACH FACE OF THE UNIT NOT LESS THAN THE THICKNESS OF THE LONGITUDINAL FACE SHELLS, BOND SHALL BE PROVIDED BY LAPPING UNITS IN

SUCCESSIVE VERTICAL COURSES.

4.11 PROVIDE VERTICAL CONTROL JOINTS BETWEEN REINFORCED MASONRY WALLS AND PARTITION WALLS, AND AT A

MINIMUM OF 20’-0” O.C.

5.00 POST-INSTALLED ANCHORS OR REBAR

5.01 EXCEPT WHERE INDICATED ON THE DRAWINGS, POST-INSTALLED ANCHORS SHALL CONSIST OF THE FOLLOWING ANCHOR TYPES AS PROVIDED BY HILTI, INC. CONTACT HILTI AT (800) 879-8000 FOR PRODUCT RELATED QUESTIONS. HILTI ANCHORS WERE USED AS THE BASIS OF DESIGN. EQUIVALENTS MAY BE SUBMITTED FOR APPROVAL.

a) REBAR DOWELING INTO CONCRETE: ADHESIVE ANCHORS FOR CRACKED AND UNCRACKED CONCRETE USE:

(1) HILTI HIT-HY 200 SAFE SET SYSTEM WITH HILTI HOLLOW DRILL BIT SYSTEM W/ CONTINUOUSLY DEFORMED REBAR

PER ICC ESR-3187.

(2) HILTI HIT-RE 500-V3 EPOXY ADHESIVE ANCHORING SYSTEM WITH CONTINUOUSLY DEFORMED REBAR PER ICC

ESR-2322.

b) ANCHORAGE TO SOLID GROUTED MASONRY: ADHESIVE ANCHORS USE:

(1) HILTI HIT-HY 70 MASONRY ADHESIVE ANCHORING SYSTEM (ICC PENDING).

5.02 ANCHOR CAPACITY USED IN DESIGN SHALL BE BASED ON THE TECHNICAL DATA PUBLISHED BY HILTI OR DEWALT OR SIMPSON OR SUCH OTHER METHOD AS APPROVED BY THE STRUCTURAL ENGINEER OF RECORD. SUBSTITUTION REQUESTS FOR ALTERNATE PRODUCTS MUST BE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER OF RECORD PRIOR TO USE.

CONTRACTOR SHALL PROVIDE CALCULATIONS DEMONSTRATING THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING THE PERFORMANCE VALUES OF THE SPECIFIED PRODUCT. SUBSTITUTIONS WILL BE EVALUATED BY THEIR HAVING AN ICC ESR SHOWING COMPLIANCE WITH THE RELEVANT BUILDING CODE FOR SEISMIC USES, LOAD RESISTANCE, INSTALLATION CATEGORY, AND AVAILABILITY OF COMPREHENSIVE INSTALLATION INSTRUCTIONS. ADHESIVE ANCHOR EVALUATION WILL ALSO

CONSIDER CREEP, IN-SERVICE TEMPERATURE AND INSTALLATION TEMPERATURE.

5.03 INSTALL ANCHORS PER THE MANUFACTURER INSTRUCTIONS, AS INCLUDED IN THE ANCHOR PACKAGING AND IN STRICT

ACCORDANCE WITH THE CURRENT ICC ESR.

5.04 OVERHEAD ADHESIVE ANCHORS MUST BE INSTALLED USING THE HILTI PROFI SYSTEM

OR POWERS PISTON PLUG METHOD OR SIMPSON RETAINING CAP SYSTEM AND IN STRICT ACCORDANCE WITH THE

CURRENT ICC ESR.

5.05 THE CONTRACTOR SHALL ARRANGE AN ANCHOR MANUFACTURER’S REPRESENTATIVE TO PROVIDE ONSITE INSTALLATION TRAINING FOR ALL OF THEIR ANCHORING PRODUCTS SPECIFIED. THE STRUCTURAL ENGINEER OF RECORD MUST RECEIVE DOCUMENTED CONFIRMATION THAT ALL OF THE CONTRACTOR’S PERSONNEL WHO INSTALL ANCHORS ARE

TRAINED PRIOR TO THE COMMENCEMENT OF INSTALLING ANCHORS.

5.06 ANCHOR CAPACITY IS DEPENDANT UPON SPACING BETWEEN ADJACENT ANCHORS AND PROXIMITY OF ANCHORS TO EDGE OF CONCRETE. INSTALL ANCHORS IN ACCORDANCE WITH SPACING AND EDGE CLEARANCES INDICATED ON THE

DRAWINGS.

5.07 EXISTING REINFORCING BARS IN THE CONCRETE STRUCTURE MAY CONFLICT WITH SPECIFIC ANCHOR LOCATIONS.

UNLESS NOTED ON THE DRAWINGS THAT THE BARS CAN BE CUT, THE CONTRACTOR SHALL REVIEW THE EXISTING STRUCTURAL DRAWINGS AND SHALL UNDERTAKE TO LOCATE THE POSITION OF THE REINFORCING BARS AT THE LOCATIONS OF THE CONCRETE ANCHORS, BY HILTI FERROSCAN, GPR, X-RAY, CHIPPING OR OTHER MEANS.

5.08 INSTALLATION OF ADHESIVE ANCHORS IN HORIZONTAL TO VERTICALLY OVERHEAD ORIENTATION SHALL BE DONE BY A CERTIFIED ADHESIVE ANCHOR INSTALLER (AAI) AS CERTIFIED THROUGH ACI AND IN ACCORDANCE WITH ACI 318-2011 (SECTION D.9.2.2). PROOF OF CURRENT CERTIFICATION SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO

COMMENCEMENT OF INSTALLATION.

5.09 PROVIDE SPECIAL INSPECTION FOR ALL MECHANICAL AND ADHESIVE ANCHORS PER THE APPLICABLE BUILDLING CODE

AND PER THE CURRENT ICC-ES REPORT FOR THE ANCHOR.

6.00 SHORING AND FORMWORK NOTES

6.01 ALL SHORING EQUIPMENT IS TO BE ERECTED IN ACCORDANCE WITH ALL APPLICABLE SAFETY STANDARDS AND THE GENERAL RECOMMENDATIONS OF THE C.S.A. STANDARD S269.1, ACI, OSHA AND THE SCAFFOLDING, SHORING AND FORMING INSTITUTE, INC. ALL FALL PROTECTION REQUIREMENTS ARE TO BE FOLLOWED IN ACCORDANCE WITH LOCAL REQUIREMENTS.

6.02 ALL SHORING EQUIPMENT MUST BE ERECTED PLUMB AND LEVEL IN BOTH DIRECTIONS, UNLESS OTHERWISE INDICATED

ON THE DRAWING.

6.03 ALL LOADS BETWEEN STRUCTURAL MEMBERS OF THE SYSTEM MUST BE TRANSFERRED CONCENTRICALLY.

6.04 IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL DIMENSIONS ON THESE DRAWINGS WITH THE SITE. ANY DISCREPANCY MUST BE REPORTED TO JOE DEREUIL ASSOCIATES, LLC BEFORE PROCEEDING WITH WORK.

6.05 ALL SHORING AND FORMWORK ACCESSORIES MUST BE PROPERLY ATTACHED AND SECURELY FASTENED BEFORE

CONCRETE PLACEMENT.

6.06 THE CONTRACTOR IS TO HAVE SOLE RESPONSIBILITY FOR COMPLIANCE WITH THE SAFETY REQUIREMENTS FOR FALSEWORK DURING DISMANTLING, FLYING AND ERECTION OF FORMS. THE CONTRACTOR IS RESPONSIBLE FOR THE FINAL INSPECTION OF SHORING AND FORMWORK TO ENSURE THE COMPLIANCE WITH THE APPROVED DRAWINGS AND GOOD

ERECTION PRACTICE.

6.07 ALL APPLICABLE SAFETY STANDARDS FOR SHORING AND FORMWORK MUST BE FOLLOWED DURING ERECTION OF ALL

EQUIPMENT AND DURING THE CONCRETE PLACEMENT.

6.08 IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ALL DIMENSIONS ON SITE. ANY DISCREPENCY IS TO BE REPORTED

TO JOE DEREUIL ASSOCIATES, LLC BEFORE PROCEEDING WITH THE WORK.

6.09 DESIGN OF LUMBER USED FOR SHORING AND FORMWORK IS THE RESPONSIBILITY OF THE CONTRACTOR. ANY LUMBER SHOWN ON THIS DRAWING IS FOR THE GUIDANCE OF THE CONTRACTOR. THE SUGGESTED LUMBER SIZES SHOWN HAVE BEEN DETERMINED IN ACCORDANCE WITH THE C.S.A. STANDARD 086.1 OR THE NATIONAL DESIGN SPECIFICATIONS FOR WOOD

CONSTRUCTION (U.S.-1977), OR THE LATEST EDITIONS OF THE ABOVE.

6.10 ALL LUMBER MUST BE FREE FROM CRACKS, SPLITS, LARGE KNOTS, AND OTHER DEFECTS. REFER TO APPLICATION

DRAWINGS FOR MEMBER SIZES AND LUMBER SPECIFICATIONS FOR EACH PROJECT.

6.11 THE WORKING STRESSES INCLUDE ALLOWANCE FOR LOADING OF SHORT DURATION AND WERE USED TO ESTABLISH THE SUGGESTED LUMBER SIZES. (ALLOWANCES ARE BASED ON THE APPLICABLE DESIGN CODES).

6.12 THE PLYWOOD IS TO BE 7-PLY 11/16" (17.5 MM), G2S OR AMERICAN PLYWOOD ASSOCIATION CLASS 1 PLYWOOD, OR

BETTER UNLESS SPECIFIED OTHERWISE ON THE APPLICATION DRAWING.

6.13 THE FACE GRAIN OF PLYWOOD IS TO RUN PERPENDICULAR TO ITS SUPPORTS.

6.14 THE DENSITY OF CONCRETE USED IN THE DESIGN OF SHORING IS 150 LBS./CU.FT. (23.6 KN/M³) UNLESS NOTED

OTHERWISE ON THE APPLICATION DRAWING.

6.15 THE LIVE LOAD USED IN THE DESIGN IS 50 LBS./SQ.FT (2.4 KN/M2) AND INCLUDES 10 LBS./SQ.FT. (0.48 KN/M²) ALLOWANCES FOR SHORING AND FORMING MATERIAL, UNLESS OTHERWISE NOTED ON THE APPLICATION DRAWING.

IA

R

E

OF

RC

SP

EC

IA

AN

N

P

ER

L O

AT

IO

M M

S

CO

D

SHEET REFERENCE:

D A

T E

SHEET NUMBER:

OF

D E

S C

R

IP

T

IO

N R

E V

A

IR

F O

R C

E

SP

EC

IA

L O

PE

R

A

TI

O N

S C

O M

M A

N D

SP

EC

IA

L O

PE

R

A

TI

O N

S C

IV

IL

E N

G

IN

EE

R

S Q

U A

D R

O N

H U

R

LB

U R

T

FI

E

LD

, F

LO

R

ID

A

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90208

S-101

100% DESIGN SUBMITTAL

01/30/2019

G E

N E

R A

L N

O T

E S

MLM

MLM

CP1026752

R E

P A

IR

C

O M

M A

N D

P O

S T

S O

A O

S B

U

IL

D

IN

G

1/28/19

'-4

1' -0

4' -8

S-102

SEE ARCH FOR NON-LOAD

BEARING WALL DEMO AND

DETAILING

EXISTING OPENING TO BE REMOVED

AND WIDENED W/ NEW WINDOW

G.C. NOTE: FIELD VERIFY ALL CONDITIONS

BEFORE BEGINING WORK. SHORE ALL ROOF

FRAMING MEMBERS IN AREA BEFORE DEMO.

**VERIFY DIMENSIONS WITH ARCHITECTURAL

PLANS, DOOR AND WINDOW SCHEDULES.

'-0

7' -5

/4

3'

-4

DEMO WALL BELOW DOOR

OPENING TO MATCH FLOOR

ELEVATION

Ground Floor 0"

Roof 13'-4"

10'-4" 1'-0" 4'-8"

4' -2

3'

-1 0"

9' -4

'-8

1' -4

TOP OF FOOTING

-2'-0"

EXISTING BOND BEAM TO REMAIN

EXIST WALL FOOTING TO REMAIN

2' -0

**FIELD VERIFY LOCATIONS OF EXISTING ROOF JOISTS.

PROVIDE PROPERLY DESIGNED POST SHORES TO

SUPPORT EACH ROOF JOIST BEFORE BEGINING ANY

DEMOLITION WORK.

TOP OF CONCRETE DECK

ELEV. +13'-0" **

JOIST BEARING EL. +12'-5 1/2"**

BACK TO EXISTING MASONRY JOINTS

18'-0"-TO- 18'-8" ** EXTENTS OF DEMOLITION

DEMO WALL TO

BOTTOM OF SLAB

EXISTING WALL

TO REMAIN

COORDINATE WITH ARCH PLANS,

START AND STOP EXTENTS OF

DEMO AT EXISTING MASONRY JOINTS.

COORDINATE WITH ARCH PLANS,

START AND STOP EXTENTS OF

DEMO AT EXISTING MASONRY JOINTS.

EXISTING WALL

TO REMAIN

LEAVE EXISTING WALL

REINFORCING EXPOSED

TO BE POURED W/ NEW

HEADER BEAM

DEMO WALL BELOW DOOR

OPENING TO MATCH FLOOR

ELEVATION

EXISTING DOOR

OPENING TO REMAIN

PURCHASE DOOR W/ DEEP

HEADER AT TOP TO SET

DOOR AT NEW ELEVATION

1'-4 1/4" ** 1'-4" **

DRILL AND EPOXY

6" INTO EXISTING

FILLED CELLS, TYP

(4)-#4 VERTICAL BARS

(4)-#4 VERTICAL BARS

EACH SIDE OF OPENING.

TYPICAL AT 12" O.C.

SEE HEADER DETAIL

FOR REINFORCING.

TYP ACROSS 18'-8"**

INFILL W/ #4 BARS AT 8" O.C., E.W.

W/ (2) HORIZ BARS AT TOP AND BOT

OF WINDOW OPENING

TYPICAL AT ALL JAMBS,

#3 CLOSED TIES AT 8" O.C.

CONC. BEAM

EXISTING CMU TO REMAIN

#3 TIES AT 10" O.C.

CHAMFER EXPOSED CORNERS

EXISTING REINFORCING

TO REMAIN

2' -0

3/4" CLR

(2) #5 CONT.

(3) #6 CONT.

SHORE EXISTING JOISTS

UNTIL BEAM HAS BEEN

CONSTRUCTED AND

FORMS REMOVED

7 5/8"

EXISTING WALL

TO REMAIN

DEMO WALL OR DEMO

EXISTING BOTTOM OF

DOOR OPENING DOWN

TO REQUIRED ELEVATION

EXISTING SLABS

NEW 1/2" PJF (IF REQUIRED)

SEE ARCH FOR DOOR

DIMENSIONS AND FLOOR

ELEVATIONS TO MATCH

NEW CONCRETE CAP ON TOP

OF WALL. MIN 4" THICK AND

REINF W/ SINGLE #4 BAR

a a a a

WIND LOAD DETERMINATION ASSUMPTIONS

ROOF SLOPE

156 C 20 3 ON 12 IV ENCLOSED

ULTIMATE DESIGN WIND PRESSURES FOR COMPONENTS AND CLADDING (PSF)

ROOF ZONE 1

ROOF ZONE 2 ROOF ZONE 3

WALL ZONE 4 WALL ZONE 5

O-HANG O-HANG

33 -52 -90 57 -61 -76

50 26 -48 -73 51 -55 -64

23 -47 -66 48 -53 -59

NOTES:

1. FOR EFFECTIVE AREAS BETWEEN THOSE GIVEN ABOVE THE LOAD MAY BE INTERPOLATED,

OTHERWISE USE THE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREA.

2. THE EDGE STRIP, a = 8 FT.

3. PRESSURES SHALL BE APPLIED IN ACCORDANCE WITH THE FIGURE SHOWN ON THIS SHEET.

< 10

> 100

WIND VELOCITY

(MPH)

EXPOSURE

CATEGORY

MEAN ROOF

HEIGHT (FT.)

RISK

CATEGORY

ENCLOSURE

CATEGORY

EFF.

AREA

(SQ. FT)

4. PRESSURES GIVEN ARE ULTIMATE LOADS TO BE USED WITH STRENGTH DESIGN. FOR

SERVICE LOADS TO BE USED WITH ALLOWABLE STRESS DESIGN, MULTIPLY THE PRESSURES

BY 0.60. SEE TABLES 2.3 AND 2.4 IN ASCE 7-10 FOR MORE INFORMATION ON LOAD

COMBINATIONS.

-10533

-90

-73

-66

-105

-105

-105

-105

-105

EXISTING WALLS W/ BOTH

REBAR AND HORIZ JOINT

REINFORCING TO REMAIN.

TERMINATE IN NEW JAMB.

**DEMO BACK TO EXISTING

WALL BLOCK JOINTS

SEE ELEVATION

5/

8"

(4)-#4 VERTICAL BARS W/

#3 CLOSED TIES AT 8" O.C.

3/ 4"

C

LR

IA

R

E

OF

RC

SP

EC

IA

AN

N

P

ER

L O

AT

IO

M M

S

CO

D

SHEET REFERENCE:

D A

T E

SHEET NUMBER:

OF

D E

S C

R

IP

T

IO

N R

E V

A

IR

F O

R C

E

SP

EC

IA

L O

PE

R

A

TI

O N

S C

O M

M A

N D

SP

EC

IA

L O

PE

R

A

TI

O N

S C

IV

IL

E N

G

IN

EE

R

S Q

U A

D R

O N

H U

R

LB

U R

T

FI

E

LD

, F

LO

R

ID

A

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90208

S-102

100% DESIGN SUBMITTAL

01/30/2019

P A

R T

IA

L

D E

M O

LI

T

IO

N

P

LA

N

MLM

MLM

CP1026752

R E

P A

IR

C

O M

M A

N D

P O

S T

S O

A O

S B

U

IL

D

IN

G

1/8" = 1'-0"S-102

1 PARTIAL DEMOLTION PLAN

PLAN

NORTH

3/8" = 1'-0"S-102

2 PARTIAL ELEVATION - NEW WALL OPENING

*DIMENSIONS ARE MINIMUMS

DEMO BACK TO COURSING W/

THE EXISTING BLOCK JOINTS.

**FIELD VERIFY EXISTING DIMENSIONS.

1" = 1'-0"S-102

3 NEW HEADER DETAIL

1" = 1'-0"S-102

4 NEW BOTTOM OF OPENING DETAIL

1" = 1'-0"S-102

5 TYPICAL JAMB DETAIL

1/28/19

L A/C

ACT

ADJ

AFF

ALT

ALUM

ARCH

AUTO

BD

BLDG

BM

BOT

BRG

BRG PL

BUR

C

CAB

CB

CEM

CF/CI

CF/GI

CI

CID

CIP

CJ

CL

CLG

CLR

CM

CMU

CPT

COL

CONC

COND

CONSTR

CONT

CONTR

COR

CORR

COTR

CU FT

CU YD

D

DET

DF

DIA

DIM

DIV

DS

DW

DWG

E

EF

EL

ELEC

ELEV

EQ

EQUIP

EMER SHR

EWS

EWC

EXH

EXIST

EXT

AND

AT

ANGLE

AIR CONDITION

ACOUSTICAL CEILING TILE

ADJACENT, ADJOINING,

ADJUSTABLE

ABOVE FINISHED FLOOR

ALTERNATE

ALUMINUM

ARCHITECT(URAL)

AUTOMATIC

BOARD

BUILDING

BEAM, BENCH MARK

BOTTOM

BEARING

BEARING PLATE

BUILT-UP ROOFING

CHANNEL

CABINET

CATCH BASIN

CEMENT

CONTRACTOR FURNISHED

CONTRACTOR INSTALLED

CONTRACTOR FURNISHED/

GOVERNMENT INSTALLED

CAST IRON

COMPREHENSIVE INTERIOR

DESIGN PACKAGE

CAST-IN-PLACE, CAST IRON PIPE

CONSTRUCTION JOINT/CONTROL

JOINT

CENTER LINE, CLASS, CLOSE

CEILING

CLEAR, COLOR, COOLER

CENTIMETER(S)

CONCRETE MASONRY UNIT

CARPET

COLUMN

CONCRETE

CONDITION

CONSTRUCTION

CONTINUE, CONTINUOUS

CONTRACT, CONTRACTOR

CONTRACTING OFFICER'S

REPRESENTATIVE

CORRIDOR

CONTRACTING OFFICER

TECHNICAL REPRESENTATIVE

CUBIC FEET

CUBIC YARD

DRYER

DETAIL

DRINKING FOUNTAIN

DIAMETER

DIMENSION

DIVISION, DIVIDE

DOWNSPOUT

DISHWASHER

DRAWING

EAST

EACH FACE

ELEVATION

ELECTRIC(AL)

ELEVATOR

EQUAL

EQUIPMENT

EMERGENCY SHOWER

EYE WASH STATION

ELECTRIC WATER COOLER

EXHAUST

EXISTING

EXTERIOR

FAX

FA

FD

FDTN

FE

FEC

FF EL

FIN GR

FLR

FP

FT

FTG

FRZ

GA

GALV

GB

GC

GF/GI

GF/CI

GL

GLZ

GMS

GDR

GR LN

GYP BD

HB

HC

HDBD

HDW

HM

HORIZ

HNDRL

HT

HVAC

IBC

ID

INCL

INSUL

INT

INV

INV EL

JS

KIT

LAM

LAV

LH

M

MAX

MECH

MFR

MH

MIN

MISC

MM

MS

MT

MTD

MTG

MTL

MW

MULL

N

NAT

NIC

NOM

NTS

OC

OD

OF/OI

OF/CI

FACSIMILE

FIRE ALARM

FLOOR DRAIN

FOUNDATION

FIRE EXTINGUISHER

FIRE EXTINGUISHER CABINET

FINISH FLOOR ELEVATION

FINISH GRADE

FLOOR

FIREPROOF

FEET, FOOT

FOOTING

FREEZER

GAGE

GALVANIZED IRON

GRAB BAR

GENERAL CONTRACTOR

GOVERNMENT FURNISHED/

GOVERNMENT INSTALLED

GOVERNMENT FURNISHED/

CONTRACTOR INSTALLED

GLASS

GLAZING

GALVANIZED METAL STUD

GUARDRAIL

GRADE LINE

GYPSUM BOARD

HOSE BIBB

HANDICAP, HOLLOW CORE

HARDBOARD

HARDWARE

HOLLOW METAL

HORIZONTAL

HANDRAIL

HEIGHT

HEATING/VENTILATING/AIR COND

INTERNATIONAL BUILDING CODE

INSIDE DIAMETER

INCLUDED

INSULATION

INTERIOR

INVERT

INVERT ELEVATION

JANITOR SINK

KITCHEN

LAMINATE

LAVATORY

LEFT HAND

METER

MAXIMUM

MECHANICAL

MANUFACTURER

MANHOLE

MINIMUM

MISCELLANEOUS

MILLIMETER

MOP SINK

MOUNT

MOUNTED

MOUNTING

METAL

MICROWAVE

MULLION

NORTH

NATURAL

NOT IN CONTRACT

NOMINAL

NOT TO SCALE

ON CENTER

OUTSIDE DIAMETER

OWNER FURNISH/

OWNER INSTALLED

OWNER FURNISH/

CONTRACTOR INSTALLED

ABBREVIATIONS

OH

OH DR

OPNG

OPP

PCF

PCC

PL

PLAM

PLYWD

PRKG

PSF

PSI

PT

PVC

QT

R

RA

RCP

RD

REBAR

REF

REG

REINF

RET

REV

RFCP

RFG

RH

RM

ROW

S

SC

SCHED

SD

SECT

SF

SHT

SIM

SPEC

SPKR

SQ

SS

SST

STA

STC

STD

STOR

STRUCT

SUSP

SYMM

SYS

T&B T&G

TE

TEL

THK

TOC

TOP

TOS

TV

TYP

UNO

VERT

VCT

VTR

W W/ W/O

WB

WC

WD

WH

WP

WSCT

WWR

OVERHANG, OVERHEAD

OVERHEAD (COILING) DOOR

OPENING

OPPOSITE

POUNDS PER CUBIC FOOT

PRECAST CONCRETE

PROPERTY LINE

PLASTIC LAMINATE

PLYWOOD

PARKING

POUNDS PER SQUARE FOOT

POUNDS PER SQUARE INCH

PRESSURE TREATED

POLYVINYL CHLORIDE

QUARRY TILE

RADIUS, RANGE, RISER

RETURN AIR

REFLECTED CEILING PLAN

ROOF DRAIN

REINFORCING STEEL BARS

REFERENCE, REFRIGERATOR

REGISTER

REINFORCE

RETURN

REVISION

REINFORCED CONCRETE PIPE

ROOFING

RIGHT HAND

ROOM

RIGHT OF WAY

SOUTH

SOLID CORE

SCHEDULE

STORM DRAIN

SECTION

SQUARE FOOT(FEET)

SHEET

SIMILAR

SPECIFICATION

SPEAKER

SQUARE

SERVICE SINK

STAINLESS STEEL

STATION

SOUND TRANSMISSION CLASS

STANDARD

STORAGE

STRUCTURAL

SUSPEND

SYMMETRICAL

SYSTEM

TOP AND BOTTOM

TONGUE AND GROOVE

TOP ELEVATION

TELEPHONE

THICKNESS

TOP OF CONCRETE

TOP OF PAVEMENT

TOP OF SLAB, TOP OF STEEL

TELEVISION

TYPICAL

UNLESS NOTED OTHERWISE

VERTICAL

VINYL COMPOSITION TILE

VENT THROUGH ROOF

WASHER, WEST, WIDE

WITH

WITHOUT

WOOD BASE

WATER CLOSET

WOOD

WATER HEATER

WATERPROOFING

WAINSCOT

WELDED WIRE REINFORCEMENT

SYMBOLS LEGEND

ROOM NAME / NUMBER

DESIGNATION

DOOR NUMBER

WINDOW / LOUVER

TYPE

WALL TYPE

ELEVATION

TARGET

ELEVATION NUMBER

INTERIOR ELEVATION SYMBOL

SHEET ON WHICH

ELEVATION IS DRAWN

ELEVATION NUMBER

EXTERIOR ELEVATION SYMBOL

SHEET ON WHICH

ELEVATION IS DRAWN

NORTH ARROW

SECTION NUMBER

SECTION SYMBOL

SHEET ON WHICH

SECTION IS DRAWN

DETAIL NUMBER

DETAIL SYMBOL

SHEET ON WHICH

DETAIL IS DRAWN

PLAN

NORTH

A-101

SIM

A

A

4 A-200

ROOM NAME

PLAN NORTH

TRUE NORTH

A-201

A-201

WALL TYPE "2"

3 5/8" GALVANIZED METAL STUDS AT 16" O.C. W/ ONE

LAYER 5/8" TYPE "X" GYPSUM WALLBOARD ON ONE SIDE

W/ 2 1/2" GALVANIZED METAL STUDS AT 16" O.C. AND ONE

LAYER 5/8" TYPE "X" GYPSUM WALLBOARD OPP. SIDE.

PARTITION TO EXTEND TO 6" ABOVE HIGHEST ADJACENT

CEILING.

WALL TYPE "4"

7 5/8" CAST-IN-PLACE CONCRETE W/ ONE LAYER 5/8" TYPE

"X" GYPSUM WALLBOARD ON W/ 2 1/2" GALVANIZED METAL

STUDS AT 16" O.C. ONE SIDE & 3 5/8" GALVANIZED METAL

STUDS AT 16" O.C. OPP. SIDE. GYPSUM WALLBOARD AND

STUDS TO EXTEND TO 6" ABOVE HIGHEST ADJACENT

CEILING.

5/ 8"

1/

2"

5/ 8"

5/

8" 5/

8"

8"

5/ 8"

5/

8" 2"

5/

8"

1/

2"

5/ 8"

1' -5

WALL TYPE "1"

3 5/8" GALVANIZED METAL STUDS AT 16" O.C. W/ ONE

LAYER 5/8" TYPE "X" GYPSUM WALLBOARD ON EACH SIDE.

PARTITION TO EXTEND TO 6" ABOVE HIGHEST ADJACENT

CEILING.

5/ 8"

5/

8" 5/

8"

7/

8"

WALL TYPE "5"

3 5/8" GALVANIZED METAL STUDS AT 16" O.C. W/ ONE

LAYER 5/8" TYPE "X" GYPSUM WALLBOARD ON ONE SIDE

OVER EXISTING INTERIOR WALL SYSTEM TO REMAIN.

PARTITION TO EXTEND TO 6" ABOVE HIGHEST ADJACENT

CEILING.

5/ 8"

1/

2"

1/

8"

WALL TYPE "1"

3 5/8" GALVANIZED METAL STUDS AT 16" O.C. W/ ONE

LAYER 5/8" TYPE "X" GYPSUM WALLBOARD ON EACH SIDE.

PARTITION TO EXTEND TO 6" ABOVE HIGHEST ADJACENT

CEILING.

5/ 8"

5/

8" 5/

8"

7/

8"

1. CONTRACTOR WILL REQUIRE USER ESCORT FOR ALL WORK EFFORT INSIDE B90208. CONTRACTOR TO COORDINATE ESCORT REQUIREMENTS & CONSTRUCTION SCHEDULE W/ CONTRACTING OFFICER & GOVERNMENT REPRESENTATIVE PRIOR TO CONSTRUCTION.

2. NO SIGNIFICANT CHANGE IN EXISTING LIFE SAFETY OR OCCUPATIONAL LOAD OCCURING W/ THIS RENOVATION. ALL EXISTING EGRESS & EXIT

WAY LOCATIONS FOR THE FACILITY ARE TO REMAIN.

GENERAL NOTES

IA

R

E

OF

RC

SP

EC

IA

AN

N

P

ER

L O

AT

IO

M M

S

CO

D

SHEET REFERENCE:

D A

T E

SHEET NUMBER:

OF

D E

S C

R

IP

T

IO

N R

E V

A

IR

F O

R C

E

SP

EC

IA

L O

PE

R

A

TI

O N

S C

O M

M A

N D

SP

EC

IA

L O

PE

R

A

TI

O N

S C

IV

IL

E N

G

IN

EE

R

S Q

U A

D R

O N

H U

R

LB

U R

T

FI

E

LD

, F

LO

R

ID

A

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90208

A-001

100% DESIGN SUBMITTAL

01/30/2019

LE

G

E N

D S

, N O

T E

S A

N D

A B

B R

E V

IA

T

IO

N

S

JGH

RCR

CP1026752

R E

P A

IR

C

O M

M A

N D

P O

S T

S

O A

O S

B

U

IL

D

IN

G

1 1/2" = 1'-0"A-001

1 WALL TYPES

SCALE: 1/4" = 1'-0"

0 2' 4' 8'

AR94997

DERETSI

G

E R

A R C H

IT

E C

T

FOETAT

S

FL O R ID

A

R IC

E

ACREBO

R

BREAK ROOM

E-119

TOILET

E-118

UNISEX TOILET

E-117

N.C.O.I.C.

E-115

RADIO ROOM

E-114

CP ADMIN. /

SORTS TRAINING

E-120

SUPT.

E-121

MECHANICAL

E-122

ELEC.

E-112

O.I.C.

E-111

SECURE COMM.

E-107

STORAGE

E-106

COMM.

E-108

STORAGE

E-109

CORRIDOR

E-113

SECURITY

E-101

SECURE

VESTIBULE

E-100

COMMAND POST

E-103

EXEC. C.A.T.

E-104

C.A.T. CEL

E-105

CORRIDOR

E-103A

BREAK ROOM

E-123

CORRIDOR

E-124

WOMEN

E-125

MEN

E-126

MENS SHOWER

E-126A

MECH. / ELEC.

E-127

SRC

E-128

EXEC. STAFF

AREA

E-129

OFFICE

E-130

CORRIDOR

E-131

STORAGE

E-132

STORAGE

E-133

EXISTING RAISED FLOOR

AREA

EXISTING OPERABLE

PARTITIONS AND TRACKS

GRAPHIC LEGEND

EXISTING ROOM NAME / NUMBER

DESIGNATION

ROOM NAME

E-101

1. EXISTING BUILDING PLAN BASED ON AS-BUILT

DRAWINGS DATED 02/22/2006. CONTRACTOR TO

VERIFY EXISTING CONDITIONS PRIOR TO DEMOLITION

AT AREAS OF NEW CONSTRUCTION.

2. PLAN DRAWINGS ARE GENERATED BY A CUT

THROUGH THE WALL AT A HEIGHT OF APPROXIMATELY

52”. COMPONENTS IN OR ON THE WALL ABOVE OR

BELOW THIS PLANE MAY NOT BE IDENTIFIED IN THIS

PLAN VIEW. SEE ELEVATION VIEWS FOR

IDENTIFICATION OF ALL WALL COMPONENTS AND

OPENINGS.

FLOOR PLAN NOTES -

EXISTING

IA

R

E

OF

RC

SP

EC

IA

AN

N

P

ER

L O

AT

IO

M M

S

CO

D

SHEET REFERENCE:

D A

T E

SHEET NUMBER:

OF

D E

S C

R

IP

T

IO

N R

E V

A

IR

F O

R C

E

SP

EC

IA

L O

PE

R

A

TI

O N

S C

O M

M A

N D

SP

EC

IA

L O

PE

R

A

TI

O N

S C

IV

IL

E N

G

IN

EE

R

S Q

U A

D R

O N

H U

R

LB

U R

T

FI

E

LD

, F

LO

R

ID

A

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90208

A-110

100% DESIGN SUBMITTAL

01/30/2019

F

LO

O R

P

LA

N

E X

IS

T

IN

G

JGH

RCR

CP1026752

R E

P A

IR

C

O M

M A

N D

P O

S T

S

O A

O S

B

U

IL

D

IN

G

1/8" = 1'-0"A-110

1 FLOOR PLAN - EXISTING

PLAN

NORTH

SCALE: 1/8" = 1'-0"

0 4' 8' 16'

AR94997

DERETSI

G

E R

A R C H

IT

E C

T

FOETAT

S

FL O R ID

A

R IC

E

ACREBO

R

'-0

EXISTING RAISED FLOOR

AREA TO REMAIN

A-111

REMOVE RAISED FLOOR

SYSTEM TO EXTENT REQ. FOR

WALL DEMOLITION, PREP

RAISED FLOOR TO RECEIVE

NEW FINISH

REMOVE RAISED FLOOR SYSTEM TO

EDGE OF NEW STAIR LOCATION, PREP

LOW FLOOR AND EXISTING RAISED

FLOOR TO RECEIVE NEW FINISH

REMOVE EXISTING

OPERABLE PARTITIONS

AND TRACKS

REMOVE EXISTING STAIR,

PREP FLOOR TO RECEIVE

NEW FINISH

DEMO EXISTING WALL & PREP

FLOOR TO RECEIVE NEW

FINISH. PATCH AND REPAIR

ADJACENT WALLS TO RECIEVE

NEW PAINT

DEMO EXISTING SINK AND CASEWORK. CAP

EXISTING PLUMBING SUPPLY AND DRAIN

PIPING. PREP FLOOR TO RECEIVE NEW

FINISH. PATCH AND REPAIR ADJACENT WALLS

TO RECEIVE NEW PAINT.

REMOVE EXISTING

COUNTER TOP AND

PREP WALL SURFACES

TO RECEIVE NEW FINISH

PHASE 2

PHASE 1

PHASE 1

PHASE 2

COORIDOR WALL

COVERING TO REMAIN,

MINIMIZE DAMAGE TO

EXISTING WALLS.

REMOVE EXISTING

WALL COVERING AND

PREP WALLS TO

RECEIVE NEW PAINT

REMOVE EXISTING STAIR,

PREP FLOOR TO RECEIVE

NEW FINISH

SAW CUT SLAB TO DEPTH

REQUIRED TO ROUTE POWER

AND COMM. COORDINATE W/

ELECTRICAL AND COMM

CONTRACTOR PRIOR TO

CONSTRUCTION

DOOR 119 HARDWARE TO BE

REMOVED AND REPLACED PER

NEW SCHEDULE

EXISTING DOOR TO REMAIN

REMOVE EXISTING DOOR,

FRAME AND HARDWARE

REMOVE EXISTING WALL

CONSTRUCTION AND GLASS

OPERABLE PARTITIONS (AS

INDICATED WITH DASHED LINES)

EXISTING CONSTRUCTION TO

REMAIN (AS INDICATED WITH

LIGHT SOLID LINES)

GRAPHIC LEGEND

ROOM NAME / NUMBER

DESIGNATION101

ROOM NAME

SAWCUT EXSITING SLAB FOR

NEW POWER AND COMM

ROUTING

1. THE GOVERNMENT WILL REMOVE EQUIPMENT

PRIOR TO THE BUILDING DEMOLITION.

2. REMOVE EXISTING RAISED FLOOR SYSTEM AND

SALVAGE FOR REUSE ELSEWHERE IN RENOVATED

AREA.

3. EXISTING CEILING SYSTEM AND RAISED FLOOR

SYSTEM TO BE DEMOLISHED IN NEW WORK AREA TO

NORTH EDGE OF (BATTLE STAFF) ROOM SRC 128.

CONTRACTOR TO COORDINATE EXTENT OF

DEMOLITION WITH LOCATION OF NEW CEILING AND

FLOOR SYSTEM. STARTING POINT OF NEW FINISHES

TO BE VERIFIED PRIOR TO START OF DEMO AND

CONSTRUCTION.

4. REFER TO ELECTRICAL, FIRE PROTECTION AND

MECHANICAL DRAWINGS FOR ADDITIONAL

DEMOLITION REQUIREMENTS.

5. DEMOLISH PORTION OF EXISTING WALLS TO

ACCOMMODATE NEW DUCTWORK, PIPING, CONDUITS,

ETC. REFER TO MECHANICAL, ELECTRICAL, PLUMBING

AND FIRE PROTECTION DRAWINGS.

6. ALL AREAS OF DEMOLITION TO BE SURROUNDED

BY TEMPORARY DUST CONTROL MEASURES.

7. CONTRACTOR TO REPLACE ALL EXTERIOR WALL

INSULATION AFFECTED BY RENOVATION OF

EXTERIOR WALL.

DEMOLITION NOTES

1' -4

MINIMIZE / REPAIR DAMAGE

EXISTING STEP AND RAISED

FLOOR AREA TO REMAIN

A-1113

REMOVE EXISTING WALL

AREA FOR NEW WALL

CONSTRUCTION.

COORDINATE OPENING

SIZE & WALL SHORING SIZE

PRIOR TO DEMOLITION OF

WALL AREA

'-0

BREAK ROOM

E-119

TOILET

E-118

UNISEX TOILET

E-117

N.C.O.I.C.

E-115

RADIO ROOM

E-114

CP ADMIN. /

SORTS TRAINING

E-120

SUPT.

E-121

MECHANICAL

E-122

ELEC.

E-112

O.I.C.

E-111

SECURE COMM.

E-107

STORAGE

E-106

COMM.

E-108

STORAGE

E-109

CORRIDOR

E-113

SECURITY

E-101

SECURE

VESTIBULE

E-100

COMMAND POST

E-103

EXEC. C.A.T.

E-104

C.A.T. CEL

E-105

CORRIDOR

E-103A

BREAK ROOM

E-123

CORRIDOR

E-124

WOMEN

E-125

MEN

E-126

MENS SHOWER

E-126A

MECH. / ELEC.

E-127

SRC

E-128

EXEC. STAFF

AREA

E-129OFFICE

E-130

CORRIDOR

E-131

STORAGE

E-132

STORAGE

E-133

(BATTLE STAFF)

S E

E S

T R

U C

T U

R A

L

'-4

REMOVE EXISTING CEILING TO

EXTENT REQUIRED FOR NEW

WALL CONSTRUCTION

REMOVE EXISTING OPERABLE

PARTITIONS AND TRACKS

REMOVE RAISED FLOOR

SYSTEM TO EXTENT REQ.

FOR WALL DEMOLITION, PREP

RAISED FLOOR TO RECEIVE

NEW RAISED FLOOR SYSTEM.

18'-0"

1'-4"

IA

R

E

OF

RC

SP

EC

IA

AN

N

P

ER

L O

AT

IO

M M

S

CO

D

SHEET REFERENCE:

D A

T E

SHEET NUMBER:

OF

D E

S C

R

IP

T

IO

N R

E V

A

IR

F O

R C

E

SP

EC

IA

L O

PE

R

A

TI

O N

S C

O M

M A

N D

SP

EC

IA

L O

PE

R

A

TI

O N

S C

IV

IL

E N

G

IN

EE

R

S Q

U A

D R

O N

H U

R

LB

U R

T

FI

E

LD

, F

LO

R

ID

A

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90208

A-111

100% DESIGN SUBMITTAL

01/30/2019

F

LO

O R

P

LA

N

D E

M O

LI

T

IO

N

JGH

RCR

CP1026752

R E

P A

IR

C

O M

M A

N D

P O

S T

S

O A

O S

B

U

IL

D

IN

G

1/8" = 1'-0"A-111

1 FLOOR PLAN - DEMOLTION

PLAN

NORTH

SCALE: 1/8" = 1'-0"

0 4' 8' 16'

1/4" = 1'-0"A-111

2 ENLARGED PLAN - DEMOLTION

1/4" = 1'-0"A-111

3 DEMOLITION ELEVATION

SCALE: 1/4" = 1'-0"

0 2' 4' 8'

PLAN

NORTH

AR94997

DERETSI

G

E R

A R C H

IT

E C

T

FOETAT

S

FL O R ID

A

R IC

E

ACREBO

R

DN

COMMAND POST

BATTLE STAFF

N.C.I.O.S.

JPG

GYM.

CORRIDOR

103A

CORRIDOR

104A

103A

W2

W1

NEW GLASS OPERABLE

PARTITION PANEL SYSTEM

W/ LOCKABLE PIN @

BOTTOM OF END PANEL

A-112

2 MB1 M M

M

M

MB2

BB

PHASE 1

PHASE 1

PHASE 2

PHASE 2

COPIER

EOS

CORRIDOR

MB2

A-501

M2M2M2M2 M2

M2

M2

M2

M2

'-1

1/

2"

'-2

28'-9 1/2"

GRAPHIC LEGEND

ROOM NAME / NUMBER

DESIGNATION101

ROOM NAME

DOOR NUMBER

WINDOW TYPE

WALL TYPE

A

X'-X"

FINISH FLOOR ELEVATION

NEW WALL CONSTRUCTION

EXISTING WALL

EQUIPMENT/FURNITURE, (GF/GI)

M 90" FLATSCREEN MONITOR,

WALL MOUNTED (GF/GI)

MB1

MARKER BOARD (8'X4')

EXISTING DOOR TO REMAIN

MB2

MARKER BOARD (6'X4')

BB

BULLETIN BOARD (7'X8')

HR HANDRAIL

48" FLATSCREEN MONITOR,

WALL MOUNTED (GF/GI)M2

FLOOR PLAN NOTES

1. SEE SHEET WALL CONSTRUCTION LEGEND A-001.

2. PROVIDE GYPSUM WALLBOARD CONTROL JOINTS @

30'-0" OC MAX.

3. PROVIDE BLOCKING IN WALLS FOR HANDRAILS,

CORNER GUARDS, TV BRACKETS, AND OTHER WALL

MOUNTED ITEMS.

4. REFER TO WALL SECTIONS AND PLAN DETAILS FOR

SPECIFIC WALL DIMENSIONS TO COLUMN LINE AND

EXISTING CONSTRUCTION.

6. PLAN DRAWINGS ARE GENERATED BY A CUT

THROUGH THE WALL AT A HEIGHT OF APPROXIMATELY

48”. COMPONENTS IN OR ON THE WALL ABOVE OR

BELOW THIS PLANE MAY NOT BE IDENTIFIED IN THIS

PLAN VIEW. SEE ELEVATION VIEWS FOR

IDENTIFICATION OF ALL WALL COMPONENTS AND

OPENINGS.

7. ALL FURNITURE AND EQUIPMENT (FFE) IS GFGI AND

SHOWN FOR COORDINATION.

8. CONTRACTOR IS TO REPAIR ALL DAMAGED AREAS

ADJACENT TO NEW CONSTRUCTION TO MATCH

EXISTING CONDITION TO REMAIN.

9. CONTRACTOR TO REPLACE ALL EXTERIOR WALL

INSULATION AFFECTED BY RENOVATION OF EXTERIOR

WALL.

1'-0"

V .I.

F

5' -5

/8

1'-0"

0"

0"

6"

W2

W1

103A

CORRIDOR

103A

CORRIDOR

104A

4'- 8"

MB2

/2 " 1'

-0

4' -8

1'

-4

5°

1'-0"

1'-0"

1'-0"

HR

HR

INTEGRAL ACCESS

FLOORING STAIR

A-501

M2 M2M2

A-501

IA

R

E

OF

RC

SP

EC

IA

AN

N

P

ER

L O

AT

IO

M M

S

CO

D

SHEET REFERENCE:

D A

T E

SHEET NUMBER:

OF

D E

S C

R

IP

T

IO

N R

E V

A

IR

F O

R C

E

SP

EC

IA

L O

PE

R

A

TI

O N

S C

O M

M A

N D

SP

EC

IA

L O

PE

R

A

TI

O N

S C

IV

IL

E N

G

IN

EE

R

S Q

U A

D R

O N

H U

R

LB

U R

T

FI

E

LD

, F

LO

R

ID

A

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90208

A-112

100% DESIGN SUBMITTAL

01/30/2019

F

LO

O R

P

LA

N

N E

W W

O R

K

JGH

RCR

CP1026752

R E

P A

IR

C

O M

M A

N D

P O

S T

S

O A

O S

B

U

IL

D

IN

G

1/8" = 1'-0"A-112

1 FLOOR PLAN - NEW WORK

PLAN

NORTH

SCALE: 1/8" = 1'-0"

0 4' 8' 16'

1/4" = 1'-0"A-112

2 ENLARGED PLAN

PLAN

NORTH

SCALE: 1/4" = 1'-0"

0 2' 4' 8'

AR94997

DERETSI

G

E R

A R C H

IT

E C

T

FOETAT

S

FL O R ID

A

R IC

E

ACREBO

R

EXISTING ROOF ACCESS

PANEL

8'-0"9'-0"9'-0"

9'-0"

9'-0"

9'-0"

9'-0"

9'-0"

8'-4"

9'-0"

9'-0"

8'-8"

8'-8"8'-8"

9'-0"

8'-0"

8'-8"

8'-4"

8'-4"

8'-8"

8'-0"

8'-0"

RADIO ROOM

E-114

N.C.O.I.C.

E-115

TOILET

E-118

BREAK ROOM

E-119

CP ADMIN. /

SORTS TRAINING

E-120

SUPT.

E-121

MECHANICAL

E-122

CORRIDOR

E-113

ELEC.

E-112

STORAGE

E-109

O.I.C.

E-111

COMM.

E-108

SECURE COMM.

E-107

STORAGE

E-106

MECH. / ELEC.

E-127

MENS SHOWER

E-126A

MEN

E-126

CORRIDOR

E-124

WOMEN

E-125

BREAK ROOM

E-123

SRC

E-128

C.A.T. CEL

E-105

SECURE

VESTIBULE

E-100

SECURITY

E-101

STORAGE

E-133

STORAGE

E-132

CORRIDOR

E-131

CORRIDOR

E-103A

OFFICE

E-130

EXEC. STAFF

AREA

E-129

COMMAND POST

E-103

EXEC. C.A.T.

E-104

8'-8"

8'-8"

9'-0"

9'-4"

8'-4"

9'-0"

9'-0"

1. EXISTING CEILING HEIGHTS, LAYOUTS, TYPES AND

EQUIPMENT LOCATIONS BASED ON AS-BUILT

DRAWINGS DATED 02/22/2006. CONTRACTOR TO

VERIFY EXISTING CEILING CONDITIONS PRIOR TO

DEMOLITION AT AREAS OF NEW CONSTRUCTION.

CEILING NOTES -

EXISTING

GRAPHIC LEGEND

EXISTING 2' X 2' SUSPENDED

ACOUSTICAL TILE LAY-IN CEILING

WITH GRID

EXISTING 2 X 4 FLUORESCENT

LIGHTING FIXTURE

EXISTING CEILING

DIFFUSER

EXISTING RETURN AIR

GRILLE

EXISTING EXPOSED TO

STRUCTURE

EXISTING CEILING MOUNTED

ACCESS PANEL, VERIFY SIZE AND

LOCATION

EXISTING METAL FRAMED GYPSUM

BOARD SOFFIT CEILING (PAINTED)

EXISTING PREFINISHED METAL

SOFFIT

EXISTING ROOM NAME / NUMBER

DESIGNATION

ROOM NAME

E-101

EXISTING CEILING HEIGHT, V.I.F.9'-0"

IA

R

E

OF

RC

SP

EC

IA

AN

N

P

ER

L O

AT

IO

M M

S

CO

D

SHEET REFERENCE:

D A

T E

SHEET NUMBER:

OF

D E

S C

R

IP

T

IO

N R

E V

A

IR

F O

R C

E

SP

EC

IA

L O

PE

R

A

TI

O N

S C

O M

M A

N D

SP

EC

IA

L O

PE

R

A

TI

O N

S C

IV

IL

E N

G

IN

EE

R

S Q

U A

D R

O N

H U

R

LB

U R

T

FI

E

LD

, F

LO

R

ID

A

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90208

A-150

100% DESIGN SUBMITTAL

01/30/2019

C E

IL

IN

G P

LA

N

E

X

IS

T

IN

G

JGH

RCR

CP1026752

R E

P A

IR

C

O M

M A

N D

P O

S T

S

O A

O S

B

U

IL

D

IN

G

1/8" = 1'-0"A-150

1 CEILING PLAN - EXISTING SCALE: 1/8" = 1'-0"

0 4' 8' 16'

PLAN

NORTH

AR94997

DERETSI

G

E R

A R C H

IT

E C

T

FOETAT

S

FL O R ID

A

R IC

E

ACREBO

R

REMOVE EXISTING

OPERABLE PARTITIONS

AND TRACKS

A

A

A

A

A

A

A

C

A

BB

A

B

A

1. THE GOVERNMENT WILL REMOVE EQUIPMENT

PRIOR TO THE BUILDING DEMOLITION.

2. EXISTING CEILING HEIGHTS AND EQUIPMENT

LOCATIONS BASED ON AS-BUILT DRAWINGS DATED

02/22/2006. CONTRACTOR TO VERIFY EXISTING

CEILING CONDITIONS PRIOR TO DEMOLITION FOR

NEW CONSTRUCTION.

3. EXISTING CEILING SYSTEM AND RAISED FLOOR

SYSTEM TO BE DEMOLISHED IN NEW WORK AREA TO

NORTH EDGE OF BATTLE STAFF ROOM 128.

CONTRACTOR TO COORDINATE EXTENT OF

DEMOLITION WITH LOCATION OF NEW CEILING AND

FLOOR SYSTEM. STARTING POINT OF NEW FINISHES

TO BE VERIFIED PRIOR TO START OF DEMO AND

CONSTRUCTION.

4. REFER TO ELECTRICAL, FIRE PROTECTION AND

MECHANICAL DRAWINGS FOR ADDITIONAL

DEMOLITION REQUIREMENTS.

5. DEMOLISH PORTION OF EXISTING WALLS AND

HEADERS TO ACCOMMODATE NEW DUCTWORK,

PIPING, CONDUITS, ETC. REFER TO MECHANICAL,

ELECTRICAL, PLUMBING AND FIRE PROTECTION

DRAWINGS.

6. SEE A-112 FOR CONSTRUCTION PHASING

BOUNDARIES

DEMOLITION NOTES

BREAK ROOM

E-119

CORRIDOR

E-113

SRC

E-128

STORAGE

E-132

CORRIDOR

E-131

CORRIDOR

E-103A

OFFICE

E-130

EXEC. STAFF

AREA

E-129

COMMAND POST

E-103

C.A.T. CEL

E-105

GRAPHIC LEGEND

EXISTING 2' X 2' SUSPENDED

ACOUSTICAL TILE LAY-IN CEILING

WITH GRID TO BE REMOVED

EXISTING 2 X 4 FLUORESCENT

LIGHTING FIXTURE TO REMAIN

EXISTING CEILING

DIFFUSER TO REMAIN

EXISTING RETURN AIR

GRILLE TO REMAIN

A

EXISTING CONDITIONS, NO NEW

WORK

EXISTING CEILING MOUNTED

ACCESS PANEL TO BE REMOVED

C

EXISTING SUSPENDED GYPSUM

BOARD SOFFIT CEILING TO BE

REMOVED

EXISTING 2 X 4 FLUORESCENT

LIGHTING FIXTURE TO BE REMOVED

EXISTING CEILING

DIFFUSER TO BE REMOVED

EXISTING RETURN AIR

GRILLE TO BE REMOVED

EXISTING ROOM NAME / NUMBER

DESIGNATION

ROOM NAME

E-101

EXISTING 2' X 2' SUSPENDED

ACOUSTICAL TILE LAY-IN CEILING

WITH GRID TO REMAIN

B

NOTE: ELEMENTS SHOWN ONLY IN ROOMS WITH ADJACENT

EXISTING CEILING CONSTRUCTION TO BE DEMOLISHED.

ALL OTHER EXISTING CEILING ELEMENTS TO REMAIN ARE

NOT SHOWN FOR CLARITY.

IA

R

E

OF

RC

SP

EC

IA

AN

N

P

ER

L O

AT

IO

M M

S

CO

D

SHEET REFERENCE:

D A

T E

SHEET NUMBER:

OF

D E

S C

R

IP

T

IO

N R

E V

A

IR

F O

R C

E

SP

EC

IA

L O

PE

R

A

TI

O N

S C

O M

M A

N D

SP

EC

IA

L O

PE

R

A

TI

O N

S C

IV

IL

E N

G

IN

EE

R

S Q

U A

D R

O N

H U

R

LB

U R

T

FI

E

LD

, F

LO

R

ID

A

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90208

A-151

100% DESIGN SUBMITTAL

01/30/2019

C E

IL

IN

G P

LA

N

D

E M

O

LI

T

IO

N

JGH

RCR

CP1026752

R E

P A

IR

C

O M

M A

N D

P O

S T

S

O A

O S

B

U

IL

D

IN

G

1/8" = 1'-0"A-151

1 CEILING PLAN - DEMOLITION SCALE: 1/8" = 1'-0"

0 4' 8' 16'

PLAN

NORTH

AR94997

DERETSI

G

E R

A R C H

IT

E C

T

FOETAT

S

FL O R ID

A

R ICE

ACREBO

R

BATTLE STAFF

JPG

COMMAND POST

N.C.I.O.S.

CORRIDOR

103A

8'-5"

CORRIDOR

104A

1 NEW CEILING SYSTEM AT LOCATION

OF NEW CABLE TRAY ROUTING AS

REQUIRED. LIGHTING & HVAC

DIFFUSERS & ALL OTHER CEILING

MOUNTED EQUIPMENT TO BE

REMOVED, PROTECTED & REPLACED

IN ORIGINAL LOCATION ONCE NEW

CEILING SYSTEM IS INSTALLED.

A-603

A-603

A-603

A-6031

REINSTALL EXISTING ROOF

ACCESS PANEL

A-603

A-602

GRAPHIC LEGEND

2' X 2' SUSPENDED ACOUSTICAL

TILE LAY-IN CEILING WITH GRID

2 X 4 FLUORESCENT LIGHTING

FIXTURE, SEE ELECTRICAL

DRAWINGS

CEILING DIFFUSER, SEE

MECHANICAL DRAWINGS

RETURN AIR GRILLE, SEE

MECHANICAL DRAWINGS

EXISTING CONDITIONS, NO NEW

WORK

CEILING MOUNTED ACCESS PANEL,

COORDINATE SIZE AND LOCATION

W/ EXISTING ACCESS HATCH

ROOM NAME / NUMBER

DESIGNATION101

ROOM NAME

METAL FRAMED GYPSUM BOARD

SOFFIT CEILING (PAINTED)

EXIT LIGHT, SEE ELECTRICAL

DRAWINGS FOR DIRECTIONAL

INFORMATION

1. ALL CEILING HEIGHTS ARE TO MATCH EXISTING.

2. VERIFY LOCATION OF EXISTING ACCESS PANEL PRIOR

TO CONSTRUCTION.

3. STARTING POINT OF NEW FINISHES TO BE VERIFIED

PRIOR TO START OF DEMO AND CONSTRUCTION.

4. ALL FIRE SPRINKLER HEADS, ELECTRICAL FIXTURES

AND MECHANICAL VENTS SHALL BE CENTERED WITHIN

CEILING TILES UNLESS NOTED OTHERWISE.

REFLECTED CEILING

NOTES

IA

R

E

OF

RC

SP

EC

IA

AN

N

P

ER

L O

AT

IO

M M

S

CO

D

SHEET REFERENCE:

D A

T E

SHEET NUMBER:

OF

D E

S C

R

IP

T

IO

N R

E V

A

IR

F O

R C

E

SP

EC

IA

L O

PE

R

A

TI

O N

S C

O M

M A

N D

SP

EC

IA

L O

PE

R

A

TI

O N

S C

IV

IL

E N

G

IN

EE

R

S Q

U A

D R

O N

H U

R

LB

U R

T

FI

E

LD

, F

LO

R

ID

A

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90208

A-152

100% DESIGN SUBMITTAL

01/30/2019

C E

IL

IN

G P

LA

N

N

E W

W O

R K

JGH

RCR

CP1026752

R E

P A

IR

C

O M

M A

N D

P O

S T

S

O A

O S

B

U

IL

D

IN

G

1/8" = 1'-0"A-152

1 CEILING PLAN - NEW WORK SCALE: 1/8" = 1'-0"

0 4' 8' 16'

PLAN

NORTH

AR94997

DERETSI

G

E R

A R C H

IT

E C

T

FOETAT

S

FL O R ID

A

R ICE

ACREBO

R

FASCIA PLATE

PEDASTAL BASE

DIAGONAL BRACE TO

PEDASTAL HEAD

PEDASTAL HEAD

TRIM ANGLE

ACCESS PANEL

STRINGER

6" 6"

CARPET TILE ON

ACCESS PANEL

1' -0

CARPET TILE ON ACCESS

PANEL TREAD, SEE

INTERIOR FINISH PLAN

EXISTING 5/8" GYPSUM WALL

BOARD

EXISTING 6" METAL STUD

WALL FRAMING

NEW 6" METAL STUD INFILL

AT NEW RECESS CORNER

AS NECESSARY

5/8" GYPSUM WALL BOARD

AS NECESSARY, SEAL

SEAMS, REFINISH TO LEVEL 5

FINISH AND PAINT TO MATCH

EXISTING.

5/8" 2"

NEW 3 5/8" GALV. METAL

STUDS @ 16" O.C., SEE WALL

TYPES A-001

N.C.I.O.S.

CORRIDOR

EXISTING 3 5/8" METAL STUD

WALL FRAMING

EXISTING 5/8" GYPSUM

WALL BOARD

CORNER GUARD

BENT METAL STUD AS NECESSARY

2 1/2" GALV. METAL STUD FURRING

ON C.I.P. CONCRETE WALL, SEE

WALL TYPES A-001

5/8" GYPSUM WALLBOARD

BENT METAL STUD AS NECESSARY 13

5°

1'-

1/2

"ANODIZED ALUMINUM

SLIDING WINDOW SYSTEM,

STC 29 MIN.

GYPSUM WALL BOARD ON 3 5/8"

GALVANIZED METAL STUD FRAMING,

SEE WALL TYPE / CONSTRUCTION

LEGEND ON SHEET A-001 FOR SPECIFIC

STUD AND GYPSUM BOARD

REQUIREMENTS

DOUBLE 16 GA GALVANIZED STEEL STUDS, SEE

WALL TYPE / CONSTRUCTION LEGEND ON

SHEET A-001 FOR SPECIFIC STUD AND GYPSUM

BOARD REQUIREMENTS

5/8" 3 5/8" 2" 7…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.