LFA_Burn_Trainer_Evaluation_Criteria.pdf

PDF 123 KB Posted

Attached to
Large Frame Trainer Federal contract opportunity
Solicitation number
FA3030-F1Z5038296AW01
Issued by
Department of the Air Force Air Education and Training Command

About this file

Evaluation Criteria

View the file

Other files for this federal contract opportunity

Other files attached to Large Frame Trainer, newest first.
File Type Posted
Large_Frame_Trainer_Questions_and_Answers.pdf PDF
large_Frame_SOW_15_Aug_2019.pdf PDF
Large_Frame_Trainer_Questions_and_Answers.pdf PDF
Pictures_-_Existing_Trainer_to_Be_Removed.pdf PDF
large_Frame_SOW_Update_19_June.pdf PDF
Large_Frame_Pictures.pdf PDF
Combo.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Competency Yes No Provide proof of completion of projects of similar magnitude.

Propane Supply Vaporizer(s) Minimum sized for 150 scfm flow Primary regulator rated for a minimum 60 scfm @ 20 psig Training Fires Fuel Type

Cabin Fire – propane vapor Cabin flashover-propane vapor High Wing – propane vapor Low Wing – propane vapor (two fires with blower including 3D) Low Wing ground pool – 10’X10’ – liquid propane Front Ground Pool Fires-70’X4’-8 zones-liquid propane Safety Systems Interior Safety Mandatory that all gas sensor, heat sensors, and ventilation components will be interchangeable with other fire training systems in use at the Fire Academy. See part list below.** Wireless dead-man device, Safety Pendent Gas detection sensors throughout Heat sensors in burn rooms Emergency shutoff push buttons at every exit Ventilation/extraction system capable of one air change per minute/continuous duty @ 500 degrees F. Operate at purge flow when turned on and during emergency shutdowns, during this time only the propane detection system will be operational. Fan failure will initiate emergency shutdown.

Centralized Computer control system Fire Safety System Mandatory that all Interlocked burner management cards, all valves and detectors will be interchangeable with other fire training systems used at the Fire Academy. See part list below.** Fail safe supply valve to close automatically in the event of electrical failure Fire safety shutoff valve dedicated at each fire, monitored by the interlocked system Interlocked pilot light system monitoring designed to detect and monitor pilot flame Gas pressure monitor at the propane inlet, monitored by the interlocked system Propane detection will be a dual drawn sample detection system.

Monitored by the interlocked system

Large Frame Burn Trainer Evaluation Criteria

Applicable NFPA Codes NFPA 54 – National Fuel Gas Code NFPA 58 – LP Gas Storage and Use NFPA 70 – National Electrical Codes NFPA 1403 – Standard on Live Fire Training Evolutions NFPA 1402 – Guide to Building Fire Service Training Centers

NFPA 402M – Aircraft Rescue and Firefighting Operations

** Interchangeable part list:

PLC(A2A1)

ESW1

A2A2 thru A2A6 MSA Gas Sensors Interface Control Components

Replacement parts must be coordinated with the customer and contracting office if any parts become obsolete.

File details come from the government source that posted it.