Item # _____________________________________
Quantity ___________________________________
C.S.I. Section 11400
F-20245 – Water Softening Systems – WS-80 Page 1 of 2
WATER SOFTENING SYSTEMS –
WS-80
W A
T E
R S
O
FT
E N
IN
G
S Y
S T
E M
S
- W
S -80
FEATURES:
Operating Profile
Softener will remove hardness to less than 1/2 gpg when oper-ated in accordance with the operating instructions. The system includes two tanks. This duplex configuration operates with one tank on-line during service. During regeneration cycles, one tank provides water to service and to the regenerating tank.
A water meter initiates system regeneration. The water meter measures the processed volume and is adjustable. Service flow is down-flow and regeneration flow is up-flow.
Regeneration Control Valve
The regeneration control valve is top mounted (top of media tank), and manufactured from non-corrosive materials. Control valve does not weigh more than four pounds. Control valve provides service and regeneration control for two media tanks.
Inlet and outlet ports accept a quick connect, double o-ring sealed adapter. Interconnection between tanks is made through the regeneration valve with a quick connect adapter. Control valve operates using a minimum inlet pressure of 15 psi. Pres-sure is used to drive all valve functions. No electric hook-up is required. Control valve will incorporate four operational cycles including; service, brine draw, slow rinse, and a combined fast rinse and brine refill. Service cycle operates in a down-flow di-rection. The brine cycle flows up-flow, opposite the service flow, providing a countercurrent regeneration. Control valve contains a fixed orifice eductor nozzle and self-adjusting backwash flow control. The control valve will prevent the bypass of hard water to service during the regeneration cycle.
Media Tanks
The tanks are designed for a maximum working pressure of 125 psi and hydrostatically tested at 300 psi. Tanks are made of en-gineered plastic with a 2.5 in. threaded top opening. Each tank is NSF approved. Upper distribution system is of a slot design.
Lower distribution system is of a flat plate design. Distributors will provide even flow of regeneration water and the collection of processed water.
Conditioning Media
Each softener includes uniform bead cation resin having a mini-mum exchange capacity of 30,000 grains/ft³ when regenerated with 15.0 lbs/ft³. The media is solid, of a proper particle size and contains no plates, shells, agglomerates or other shapes, which might interfere with the normal function of the water softener.
Brine System
A combination salt storage and brine production tank is manu-factured of corrosion resistant, plastic. The brine tank has a chamber to house the brine valve assembly. The brine float assembly allows for adjustable salt settings and provides for a shut-off to the brine refill. The brine tank includes a safety over-flow connection to be plumbed to a suitable drain.
Salt Alarm
Salt alarm consists of an alarm box and a brine sensor. Brine sensor is mounted internally on the grid plate and operates on the specific gravity of proper brine concentration. An alarm condition is triggered when the concentration falls below ac-ceptable level for more than 15 minutes. The alarm is both an 80-db audible alarm every 3 seconds and a red LED flash every 7 seconds. The alarm box operates on three AA batteries and connects to the brine sensor with a standard 2-wire phone cord (7' phone cord supplied).
MODEL:
❑ Model WS-80 Specifications, Details and Dimensions on Back.
Model WS-80 Salt Alarm
WATER SOFTENING SYSTEMS –
WS-80
F-20245 (REV. 02-2011)
System Components Media Vessel (qty) Size .............................................................(2) 8 x 17” Media Vessel Construction ........Fiberglass Wrapped Engineered Plastic Empty Bed Volume .......................................................................0.40 ft3
Media Type ....................................................Uniform Bead Cation Resin Media Volume ...............................................................................0.40 ft3
Bed Depth ....................................................................................Packed Free Board ...................................................................................... None Riser Tube ...................................................................................1” CPVC Distributor Upper ........0.012” Slots, Engineered Plastic Basket Lower ..........0.009” Slots, Stainless Steel Flat Plate Under bedding .................................................................................None Regeneration Control ..........................................Non-electric Use Meter Regeneration Type ............................................................Countercurrent Meter Type ................................0.30 - 25.00 gpm Polypropylene Turbine
Inlet Water Quality Pressure Range .......................................15 – 125 psi Dynamic Pressure Temperature Range ...............................................................35 – 160o F Temperature (Continuous) .............................................................150o F pH Range ..................................................................................5 – 10 SU Free Chlorine Cl2 (Max.) ..............................................................2.0 mg/l Hardness as CaCo3 (Max.) ...........................................................40 gpg
Operating Specs Flow Range (15 / 30 psig) ...............................................10.2 – 16.4 gpm Flow Configuration ..................................................................Alternating Dimensions (width x depth x height) ...................................20 x 22 x 28” Weight (operating / Shipping) .............................................220 / 100 lbs.
Connections Inlet / outlet Connections ..........................Custom Adapter and Bracket Drain Connection ......................................................................0.5” Tube Brine Line Connection ............................................0.375” Tube (internal) overflow Connection .................................................................0.5” Tube Power ...............................................................................................None Salt Alarm...........................................................................3 AA Batteries
System Part Numbers WS-80, Compact Cabinet Softener ......................................913091-125
Brine Tank Options Tank Description ...................................................................208 Cabinet Tank Height .........................................................................................28” Tank Footprint .............................................................................20 x 22” Material ...........................................................................................HDPE Salt Capacity ..................................................................................80 lbs.
Regeneration Specifications Regeneration Volume ...............................................................14 gallons Regeneration Time ..................................................................11 minutes Backwash Flow Control ............................................................1.40 gpm Brine Refill Flow Control ............................................................0.40 gpm
20" 22"
28"
Disc Selection (Compensated Hardness*) Setting Capacity Efficiency Dosing Meter Disc 1 2 3 4 5 6 7 8
1.4 lbs. 4,818 grains 3,442 gr./lb. 3.5 lbs./ft3 5 11 17 22 27 32 35 40 Gallons/Regeneration: 732 366 244 183 146 122 105 92 Flow during regeneration (@ 15 psig): 10.2 10.2 10.2 10.2 10.2 8.3 6.7 5.5 *Compensated hardness in gpg = Hardness + (3 x Fe in mg/l)
1.75"