Vent Hood Salient Characteristics

View the file

Other files for this federal contract opportunity

Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CL64eN-EGR ELECTRIC High Temperature Rack Conveyor Dishwashing Machine

CLeN SERIES – CL64eN-EGR ELECTRIC

COM

M

ERCIAL

DISHW

ASHERS

Project ____________________________________________________________________

AIA # ________________________________ SIS # ________________________________

Item # ______________________________ Quantity ________ C.S.I. Section 114000

SPECIFIER STATEMENT

Specified dishwasher will be Hobart CL64eN Energy Recovery electric tank heat model with drain water energy recovery (DWER), and Opti-Rinse™. Includes 342 racks per hour capac-ity, insulated ergonomic cabinet style doors, dirty water indicator, configurable “ intelligent” de-lime notification, top mounted computer con-trols, and NSF approved pot and pan cycle mode.

The wash tank utilizes durable precision pressure sensor monitors in lieu of conventional mechani-cal floats. The 19.5" standard chamber height will accommodate up to (6) standard sheet pans at a time on an open-end sheet pan rack.

STANDARD FEATURES

+ 342 racks per hour + Drain water energy recovery (DWER) + Opti-Rinse™ system + Rapid return conveyor drive mechanism + Internal stainless steel pressure-less 30 KW booster heater + Large double door opening for ease of cleaning + Doors are insulated & hinged with door interlock switches + 19.5" chamber height opening (accepts sheet pans) + Top mounted micro-processor control module + Energy saver mode (programmable auto-shut down) + Dirty water indicator + Manager activated low temperature alert + NSF rated configurable pot and pan dwell mode + Configurable “intelligent” delime notification + Service diagnostics + Self-aligning wash manifolds + Stainless steel anti-clogging wash arms + Removable pump intake screen + Stainless steel self-draining pump and impeller + Single, sloping scrap screen and deep scrap basket + Stainless panels enclose perimeter and bottom + Door actuated drain closure + Convertible hot water or low temp final rinse + Vent fan control + Booster heater control + ENERGY STAR® Certified

OPTIONS & ACCESSORIES (Available at extra cost) ❑ Standard, short, and extended stainless steel vent hoods ❑ Direct drive unloader – adds 38" length. Reference spec

F39520 for more details ❑ Side loader – SL23 adds 23" length, SL30 adds 30" length.

Reference specs F40926 and F40927 for more details ❑ Blower-dryer – adds 331⁄4" to length. Reference spec F40252 for more details (ships separate from dishmachine, contact

❑ Flanged feet kit (requires two kits) ❑ Higher than standard chamber (24" opening) ❑ Table limit switch ❑ Correctional package (contact Hobart for details) ❑ Pressure regulator valve (PRV), for use with external booster ❑ Water shock absorber kit ❑ Factory-mounted circuit breakers ❑ Common electrical connection (see page 4)

Page 2 of 4 CL64eN-EGR ELECTRIC

High Temperature Rack Conveyor

Dishwashing Machine

CAD and/or Revit Files Available

Top View Left to Right Top View Right to Left

Front View Left to Right Front View Right to Left

Suggested Track and Table Layout

View Showing Hole Locations in Turned Down Portion of Table

Side View

MODEL:

CL64eN ENERGY RECOVERY

L-R OPERATION

D-974805

REV B

MODEL:

CL64eN ENERGY RECOVERY

R-L OPERATION

D-974804

REV B

WIDTH OF

TRACKS

WIDTH OF

MACHINE 20" 27"

11"

27"

AVG INSIDE

TABLE WIDTH

14 1/2"

CL

MACHINE 2 HOLES FOR BOLTING

TABLE TO TANK

FRONT OF

MACHINE

CL

3/8"

3/8"

3"

1 1/4"

8" AVG

22"

INSIDE TANK

3"

P1

68 1/2"

63 1/2"10"

TYP

5" V1

P2

E1 E2

V1

P2

E2 E1

68 1/2"

63 1/2"10"

TYP

31 1/16"

7 3/8"

15 1/8"

13"

9 3/8" 5" RECOMMENDED

MIN. DISTANCE

FROM WALL

22"

BOTH ENDS

WALL

35 3/8" 43 5/16"

60 11/32"

23"

OPEN DOOR

CLEARANCE

20" SERVICE

CLEARANCE

(BOTH SIDES)

20 3/4" 28 3/4"

59 7/8"

20" SERVICE

CLEARANCE

(BOTH SIDES)

23"

OPEN DOOR

CLEARANCE

P1 P160 1/4"60 1/4"

AUTOMATIC SOIL

REMOVAL (ASR)

R-L OPER

7 3/8"7 5/8"

L-R OPER

65 9/16" 65 9/16"

P1 P1

P357 3/8" P3 57 3/8"

34" http://hobart.kclcad.com/mobile

Dishwashing Machine

CL64eN-EGR ELECTRIC Page 3 of 4

SPECIFICATIONS

Capacities Racks Per Hour (NSF rated) Wash Tank (U.S. gallons) Rinse Tank (U.S. gallons) Conveyor Speed (feet per minute) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.5 Motor Horsepower Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/6 Wash Rinse Water Consumption U.S. Gallons per Hour (maximum use at 20 PSI) U.S. Gallons per Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.39 Peak Drain Flow (U.S. gallons per minute) Heating Tank Heat, Electric (kW) Electric Booster (built-in) (kW for 70°F rise) Venting Load End (minimum CFM) Unload End (minimum CFM) Shipping Weight (approximate) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .870 lbs.

Crated Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74"L x 38"W x 78"H

LEGEND

Electrical Connections

E1 Motors, controls, and electric tank heat 1-1/4" or 2" conduit, 63-3/4" AFF.

E2 Internal electric booster 1-1/4" or 2" conduit, 63-3/4" AFF.

NOTE: Common electrical connection (single point) available, see page 4 for details.

Plumbing Connections

P1

Drain. May be drained to either side of valve, plug opposite side 2" FPT.

Recommend a floor drain minimum of 12'' from machine for access and maintenance. 7-3/8" AFF.

P2 Hot water. 1/2" FPT connection.

1/2", 11-3/16" AFF. See plumbing notes for required temperatures.

P3 Cold water connection 1/2" FPT, cold water temperature 80°F, maximum

7-3/8" AFF.

Vent Connections

V1 Optional vent hoods, 4" x 16" vent stack with damper.

E1 Electrical Connection (3 PH only) Motors, Controls and Electric Tank Heat

Voltage Rated Amps

Minimum Supply Circuit

Ampacity

Maximum Protective

Device 208/60/3 90.6 125 125 240/60/3 86.6 125 125 480/60/3 44.9 60 60

NOTE: Electric tank heat can be split from motors & c ontrols, see page 4 for details.

E2 Booster Heat 30 kW Minimum 110°F Incoming Water

Voltage Rated Amps

Minimum Supply Circuit

Ampacity

Maximum Protective

Device 208/60/3 83.9 90 90 240/60/3 80.2 90 90 480/60/3 40.1 50 50

CL64eN-EGR Electric Heat Dissipation

BTU/HR.

Latent Sensible 52,100 22,300

WARNING: Plumbing and electrical connections should be made by qualified personnel who will observe all the applicable plumbing, sanitary, safety codes and National Electrical Code.

Plumbing Notes: Minimum incoming water temperatures:

110°F for 30kW internal booster. Building flowing water pressure to dish machine is 20 PSI (+/- 5 PSI).

Single cold water connection supplies both drain water energy recovery and drain water tempering.

Dishwashing Machine

.S.A.

COMMON ELECTRICAL CONNECTION (SINGLE POINT) –

CONTACT FACTORY FOR ADDITIONAL INFORMATION

Common Electrical Connection (Includes Motors & Controls, Electric Wash Tank Heat, Electric Rinse Tank Heat & Electric Booster Heater)

Voltage

MACHINE AND 30kW BOOSTER

Rated Amps

Minimum Supply Circuit

Ampacity

Maximum Protective

Device 208/60/3 175 200 200 240/60/3 167 200 200 480/60/3 85 100 100

FIELD CONVERTIBLE SERVICE CONNECTIONS

Service connections for motors, controls, and electric tank heat for wash and rinse tanks can be split as necessary for installation.

Separate Service Connection for 15 kW Wash Tank

Voltage Rated Amps

Minimum Supply Circuit

Ampacity

Maximum Protective

Device 208/60/3 45.0 60 60 240/60/3 43.0 60 60 480/60/3 22.0 30 30

Separate Service Connection for 10 kW Rinse Tank

Voltage Rated Amps

Minimum Supply Circuit

Ampacity

Maximum Protective

Device 208/60/3 30 40 40 240/60/3 28.6 40 40 480/60/3 14.3 20 20

VENT HOOD OPTIONS (Adjustable, vent stack can be adjusted 1" to either side)

Standard Short Extended

4 3/4"

OUTSIDE

11 1/4"

OUTSIDE

REF

10" 10"

4 3/4"

OUTSIDE

5 3/4"

OUTSIDE

REF

10"

4 3/4"

OUTSIDE

20 1/2"

OUTSIDE

REF

Separate Service Connection for Motors & Controls

Voltage Rated Amps

Minimum Supply Circuit

Ampacity

Maximum Protective

Device 208/60/3 15.6 20 20 240/60/3 15.1 20 20 480/60/3 9.1 20 20