Answers.doc

DOC document 27 KB Posted

Attached to
Repair Bldgs 2503, 2504, 2505
Solicitation number
FA301017R0006A
Issued by

About this file

Questions & Answers

View the file

Other files

File Type Posted
Amendment_00003.pdf PDF
Attachment_10_Addendum_0001.pdf PDF
Amendment_00002.pdf PDF
Pre_Con_Sign_In_Redacted.pdf PDF
Amendment_00001.pdf PDF
Attachment_1_Specifications.pdf PDF
Attachment_7_Notice_of_Compliance.pdf PDF
Attachment_8_Wage_Determination.pdf PDF
Attachment_5_Reference_List.docx DOCX document
Attachment_2_Drawings_1.pdf PDF
Attachment_4_Performance_Questionnaire.doc DOC document
17R0006_Sol.pdf PDF
Attachment_3_Drawing_2.pdf PDF
Attachment_6_SF_1444.pdf PDF
Attachment_9_SOW.pdf PDF
Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FA3010-17-R-0006 Storm Damage Repair 2500 Block

Questions & Answers

Question 1: What information should an Offer present to validate or apply for a "Neutral Confidence evaluation?

A- The rating is based on the past performance information and questionnaires received with the proposal and based on the evaluation of that past performance.

Question 2: Referencing the Repairs to the gutter system: can you provide a detailed sketch that accurately describes what the finished product should look like and the procedure required to achieve the desired look?

A- See proposed sketch. Procedure would be similar to the following:

1- Cut the EPDM liner about 3" down from the roof edge and secure it out of the way

2- Install the peel and stick as shown, extending down the and over the structural metal gutter and up and over the existing cap blocking.

3- Mechanically fasten a folded metal clip on the roof side just under the existing roof.

4- Once the new metal gutter is placed and integrated with the downspouts, the metal clip would be folded back down sandwiching the roof side gutter wall in place.

5- Then a continuous clip is mechanically fastened on top of the gutter and peel and stick covering the wall cap blocking.

6- Add a roof cap to match the existing.

7- Finally the existing strip of EPDM liner can be allowed to overlap the top of the gutter, clip, and peel and stick.

Question 3: Will all the tiles where the vending machines are, need to be replaced?

A- Remove those that are loose (approximately 2 floor and 4 base) and any additional base tiles necessary to patch and repair the wall (approximately 4). Reuse existing tile and match existing grout.

File details come from the government source that posted it. Updated .