American Industrial Hygiene American Conference of Governmental Association Industrial Hygienists
Indoor Air Quality Association Inc American Council for Accredited Certification
124 Heritage Avenue #16 | Portsmouth, NH 03801 | 603.436.2001 | absoluteresourceassociates.com
Absolute Resource Associates 124 Heritage Ave #16 Portsmouth NH 03801
Roland Hartz Facility Contract Monitor ARA Project ID#: 47914 120 Grenier Street Date of Assessment: March 26, 2019 Bldg. 1810 Type of Assessment: Asbestos Hanscom AFB, MA 01731-1910
Project: B1543 walls and ceiling
Attached please find results for the assessment performed on the date referenced above.
Unless otherwise noted in the attached report, the assessment performed met the requirements of Absolute Resource Associates Standard Operating Procedures or industry guidelines and standards for the investigation of Asbestos Containing Materials (ACM) within a building. The Standard Operating Procedures for sampling and investigations are based upon OSHA and EPA standards and adhere to all state regulations. The results in this report pertain only to the samples as indicated on the chain of custody.
Absolute Resource Associates maintains certification and/or membership with the agencies listed below. We appreciate the opportunity to provide services to you. If you have any questions regarding the enclosed report, please contact us and we will be glad to assist you.
Sincerely, ________________________________ April 1, 2019 Jason Muchmore, CIE Date Indoor Air Quality Manager Council-certified Indoor Environmentalist Massachusetts Asbestos Inspector # AI900596
Absolute Resource Associates Certifications and Memberships
124 Heritage Avenue #16 | Portsmouth, NH 03801 | 603.436.2001 | absoluteresourceassociates.com
Table of Contents
I. Job and Contact Information II. Scope of Work III. Findings IV. References V. Limits of Liability VI. Attachments (as applicable):
A.Test Results B.Chain of Custody
I. Job and Contact Information
A. Contact Information:
Contact: Roland Hartz Title: Facility Contract Monitor Address: 120 Grenier Street, Bldg. 1810 Address: Hanscom AFB, MA 01731-1910 Phone: 781-367-7184 Email: roland.hartz.1@us.af.mil
B. Site Information Contact: Roland Hartz Title: Facility Contract Monitor Address: 120 Grenier Street, Bldg. 1810 Address: Hanscom AFB, MA 01731-1910 Phone: 781-367-7184 Email: roland.hartz.1@us.af.mil
ARA project#: 47914
II. Scope of Work The assessment was conducted on March 26, 2019 at the request of Roland Hartz, representing Hanscom AFB. Samples were collected from in Building 1543 from the sheetrock, sound proof wall panels, and the ceiling tiles. The object of the assessment was to establish the presence of asbestos containing material prior to renovations. A representative amount of samples were collected from each homogenous material. No joint compound was observed on the sheetrock.
Jason Muchmore (MA asbestos inspector#AI900596) of Absolute Resource Associates conducted the inspection.
The building assessment was conducted to establish the following:
● Assess the potential for Asbestos Containing Materials (ACM) in the building.
● Physically inspect building materials, sample and analyze materials.
● Collect environmental samples and analyze via Polarized Light Microscopy to determine if the material has ACM.
● Throughout the process, consult other qualified professionals if necessary or desired, III. Findings for B1543 Asbestos containing material (ACM) is material containing >1% asbestos.
The condition of ACM is categorized as Good, Fair, or Poor. The type of ACM is categorized as Surfacing (Surf.), Miscellaneous (Misc.), and Thermal System Insulation (TSI). The ACM is also determined to be either friable or non-friable.
No asbestos was detected from the sampled materials.
A. Materials sampled and tested for ACM:
• Three samples of each material were collected. A total of 9 samples were collected from the following materials:
Sample
ID
Material Location Type Friable/ Non-friable
Asbestos Analytical result
1, 2, 3 White ceiling tiles B1543 classroom and office
Misc. Friable None Detected
4, 5, 6 Wall sound proof panels
B1543 classroom and office
Misc. Friable None Detected
IV. References
a) ACGIH; American Conference of Governing Industrial Hygienist
b) AIHA; American Industrial Hygiene Association
c) EPA; Environmental Protection Agency
d) AIHA/ACGIH Journal of Occupational & Environmental Hygiene.
e) OSHA; Technical Manual
f) MADEP; Massachusetts Dep. of Environmental Protection
V. Limits of Liability The IAQ assessment does not cover concealed areas or items not inspected. The extent of the limited area also depends on the building construction and conditions, weather, building usage and other factors. Areas that were inaccessible during the investigation were not inspected. Due to the nature of the investigation and the limited data available, Absolute Resource Associates cannot warrant against undiscovered environmental liabilities.
Any use which a third party makes of this report, or reliance on decisions made based upon it, is the responsibility of such third parties. Absolute Resource Associates accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report.
The conclusions presented in this report represent the best technical judgment of Absolute Resource Associates based on the data collected from the work. The conclusions are based on the site conditions encountered by Absolute Resource Associates at the time the assessment was performed. The assessment does not cover concealed area or items not inspected. The assessment does not cover information that was concealed, or information that was not revealed during the assessment.
VI. Attachments A. Test Results B. Chain of Custody
7, 8, 9 Sheetrock behind wall sound panels
B1543 classroom and office
Misc. Non-friable
None Detected
Batch: 41102
165 New Boston St., Ste 227 Woburn, MA 01801
781-932-9600 Web: www.asbestosidentificationlab.com
Email: mikemanning@asbestosidentificationlab.com
Asbestos Identification Laboratory
Dear Jason Muchmore, Thank you Jason Muchmore for your business.
Michael Manning Owner/Director
Asbestos Identification Laboratory has completed the analysis of the samples from your office for the above referenced project .
The information and analysis contained in this report have been generated using the EPA /600/R-93/116 Method for the Determination of Asbestos in Bulk Building Materials. Materials or products that contain more than 1% of any kind or combination of asbestos are considered an asbestos containing building material as determined by the EPA. This Polarized Light Microscope (PLM) technique may be performed either by visual estimation or point counting. Point counting provides a determination of the area percentage of asbestos in a sample. If the asbestos is estimated to be less than 10% by visual estimation of friable material, the determination may be repeated using the point counting technique. The results of the point counting supersede visual PLM results. Results in this report only relate to the items tested. This report may not be used by the customer to claim product endorsement by NVLAP or any other U.S. Government Agency.
Laboratory results represent the analysis of samples as submitted by the customer. Information regarding sample location, description, area, volume, etc., was provided by the customer. Asbestos Identification Laboratory is not responsible for sample collection activities or analytical method limitations. Unless notified in writing to return samples, Asbestos Identification Laboratory discards customer samples after 30 days. Samples containing subsamples or layers will be analyzed separately when applicable. Reports are kept at Asbestos Identification Laboratory for three years. This report shall not be reproduced, except in full, without the written consent of Asbestos Identification Laboratory.
Work Received:
2019-03-27
2019-03-26
HAFB 1543
Jason Muchmore Absolute Resource Associates 124 Heritage Ave Unit 16 Portsmouth, NH 03801 2019-03-26
47914Project Number:
Project Name:
March 28, 2019
Date Sampled:
Analysis Method: BULK PLM ANALYSIS EPA/600/R-93/116
Work Analyzed:
• NVLAP Lab Code: 200919-0
• Massachusetts Certification License: AA000208
• State of Connecticut, Department of Public Health Approved Environmental Laboratory Registration Number: PH-0142
• State of Maine, Department of Environmental Protection Asbestos Analytical Laboratory License Number: LB-0078(Bulk) LA-0087(Air)
• State of Rhode Island and Providence Plantations. Department of Health Certification: AAL-121
• State of Vermont, Department of Health Environmental Health License AL934461
Work Received:
2019-03-27
2019-03-26
HAFB 1543
Jason Muchmore Absolute Resource Associates 124 Heritage Ave Unit 16 Portsmouth, NH 03801 2019-03-26
47914Project Number:
Project Name:
March 28, 2019
Date Sampled:
Analysis Method: BULK PLM ANALYSIS EPA/600/R-93/116
Work Analyzed:
Asbestos % Material Color Non-Asbestos % Location FieldID
LabID gray Mineral Wool 50
Cellulose 30 Non-Fibrous 20456519
1 B1543 Classroom & OfficeWhite Ceiling Tile None Detected gray Mineral Wool 50 Cellulose 30 Non-Fibrous 20456520
2 B1543 Classroom & OfficeWhite Ceiling Tile None Detected gray Mineral Wool 50 Cellulose 30 Non-Fibrous 20456521
3 B1543 Classroom & OfficeWhite Ceiling Tile None Detected gray Mineral Wool 50 Cellulose 30 Non-Fibrous 20456522
4 B1543 Classroom & OfficeWall Sound Panel None Detected gray Mineral Wool 50 Cellulose 30 Non-Fibrous 20456523
5 B1543 Classroom & OfficeWall Sound Panel None Detected gray Mineral Wool 50 Cellulose 30 Non-Fibrous 20456524
6 B1543 Classroom & OfficeWall Sound Panel None Detected multi Cellulose 10 Non-Fibrous 90
456525
7 B1543 Classroom & OfficeSheetrock None Detected multi Cellulose 10 Non-Fibrous 90
456526
8 B1543 Classroom & OfficeSheetrock None Detected multi Cellulose 10 Non-Fibrous 90
456527
9 B1543 Classroom & OfficeSheetrock None Detected
Analyzed by: 41102Batch:
Page 1 of 1Thursday 28 March End of Report