DEPARTMENT OF THE AIR FORCE
HEADQUARTERS 96TH TEST WING (AFMC)
EGLIN AIR FORCE BASE, FLORIDA
14 June 2022
MEMORANDUM FOR: AFTC/PZIOA
FROM:
SUBJECT: Technical Requirements Document for RF Over Fiber
1. The has a requirement to purchase RF Over Fiber solution that conforms to the following specifications:
a) 4-Channel. Each channel:
a. Supports RF signals from 0.1 MHz to 20 GHz
b. Has post amplifier
c. Is adjusted to provide unity gain (S21:0 dB)
d. Has NF =< 33 dB
e. Uses laser with different wavelength
f. Supports Maximum RF input of at least 20 dB
g. Is impedance matched to 50 Ohm for input/output
h. Has VSWR of 2:1 for input/output
i. Provides Gain flatness of ± 2.5 dB
j. Supports a P1dB Compression point of at least + 17dBm
k. Provides a spurious free dynamic range of 110 dB/Hz
l. Provides phase noise @ 10k offset of ≤ 120 dBc/Hz
b) Chassis based. Each chassis with:
a. 1U Chassis houses 4 Tx modules
b. 1U Chassis houses 4 Rx modules
c. 110 AC power
d. 4x SMA RF connectors
e. MUX to support single fiber communication
f. Supports operational Temperature range of 0 – 60 degrees Celsius
2. Delivery Requirement: 150 days ARO.