Project Title: Repair and Replace Roofs Miscellaneous Base Buildings, IDIQ
Location: IDIQ Repair and Replace Roofs at Eglin Air Force Base and buildings located w ithin the Eglin Air Force Base Reservation.
Period of Performance (PoP): From the date of aw ard through 365 days or one year plus four option years.
Block 11 below reflects the basic contract performance period and not the PoP for the issuance of the individual delivery orders w hich are negotiated.
Competition: This acquisition is 8(1) competitive and restricted to 8(a) certif ied f irms headquartered and/or have an approved bona f ide off ice in SBA's region IV as follow s: AL, FL, GA, KY, MS, NC, SC and TN.
NAICS Code: 238160, Size Standard $14 million. Please read and f ill out Section L & M to ensure compliance.
Magnitude: The magnitude of the acquisition is $1,000,000.00 to $5,000,000.00 per year.
NOTE: The Price Schedule quantities listed are for estimating purpose only.
Time Zone: Unless noted otherw ise the times listed are all Central Time zone.
CHRISTINE M YOUNG 850 882-0270
NOTE: In sealed bid solicitations "offer" and "offeror" mean "bid" and "bidder".
10. THE GOVERNMENT REQUIRES PERFORMANCE OF THE WORK DESCRIBED IN THESE DOCUMENTS
NEGOTIATED
26-May-2011
(RFP)
(IFB)
X
CALL:
B. TELEPHONE NO. (Include area code) (NO COLLECT CALLS)
2. TYPE OF SOLICITATION
SEALED BID
3. DATE ISSUED
9. FOR INFORMATION A. NAME
SOLICITATION
NSN 7540-01-155-3212 1442-101 STANDARD FORM 1442 (REV. 4-85)
Prescribed by GSA FAR (48 CFR) 53.236-1(e)
11. The Contractor shall begin performance w ithin _______5 calendar days and complete it w ithin ________365 calendar days after receiving aw ard, X notice to proceed. This performance period is X mandatory, negotiable. (See _________________________52.211-10
12 A. THE CONTRACTOR MUST FURNISH ANY REQUIRED PERFORMANCE AND PAYMENT BONDS?
(If "YES," indicate within how many calendar days after award in Item 12B.)
X YES NO
13. ADDITIONAL SOLICITATION REQUIREMENTS:
A. Sealed offers in original and __________1 copies to perform the w ork required are due at the place specif ied in Item 8 by ___________ local time ______________11 Jul 2011 (date). If this is a sealed bid solicitation, offers must be publicly opened at that time.
shall be marked to show the offeror's name and address, the solicitation number, and the date and time offers are due.
B. An offer guarantee X is, is not required.
C. All offers are subject to the (1) w ork requirements, and (2) other provisions and clauses incorporated in the solicitation in full text or by reference.
D. Offers providing less than _______60 calendar days for Government acceptance after the date offers are due w ill not be considered and w ill be rejected.
SOLICITATION, OFFER,
AND AWARD
(Construction, Alteration, or Repair)
1. SOLICITATION NO.
IMPORTANT - The "offer" section on the reverse must be fully completed by offeror.
4. CONTRACT NO.
7. ISSUED BY CODE
AAC/PKO - FA2823
308 WEST D AVENUE, SUITE 130 (BLDG 260)
EGLIN AFB FL 32542-5418
FA2823
PAGE OF PAGES
1 OF
CODE FA2823
(Title, identifying no., date):
12B. CALENDAR DAYS
04:00 PM (hour) Sealed envelopes containing offers
AAC/PKOA - CHRISTINE YOUNG
308 W. D AVE, BLDG 260, STE130
EGLIN AFB FL 32542-5418
5. REQUISITION/PURCHASE REQUEST NO. 6. PROJECT NO.
8. ADDRESS OFFER TO (If Other Than Item 7)
FAX:TEL: TEL: 850-882-0270 FAX: 850-882-9442
FA2823-11-R-0008 129
20B. SIGNATURE
(REV. 4-85)STANDARD FORM 1442 BACK
TO SIGN
NSN 7540-01-155-3212
SOLICITATION, OFFER, AND AWARD (Continued) (Construction, Alteration, or Repair)
CODE FACILITY CODE
17. The offeror agrees to perform the w ork required at the prices specif ied below in strict accordance w ith the terms of this solicitation, if this offer is accepted by the Government in w riting w ithin ________ calendar days after the date offers are due.
the minimum requirements stated in Item 13D. Failure to insert any number means the offeror accepts the minimum in Item 13D.)
AMOUNTS SEE SCHEDULE OF PRICES
18. The offeror agrees to furnish any required performance and payment bonds.
19. ACKNOWLEDGMENT OF AMENDMENTS
(The offeror acknowledges receipt of amendments to the solicitation -- give number and date of each)
AMENDMENT NO.
DATE
20A. NAME AND TITLE OF PERSON AUTHORIZED TO SIGN
OFFER (Type or print)
AWARD (To be completed by Government)
21. ITEMS ACCEPTED:
22. AMOUNT 23. ACCOUNTING AND APPROPRIATION DATA
24. SUBMIT INVOICES TO ADDRESS SHOWN IN ITEM
(4 copies unless otherwise specified)
CODE
(Insert any number equal to or greater than
20C. OFFER DATE
25. OTHER THAN FULL AND OPEN COMPETITION PURSUANT TO
10 U.S.C. 2304(c) 41 U.S.C. 253(c)
CODE27. PAYMENT WILL BE MADE BY:26. ADMINISTERED BY
(Include ZIP Code)14. NAME AND ADDRESS OF OFFEROR 15. TELEPHONE NO. (Include area code)
See Item 14
(Include only if different than Item 14)16. REMITTANCE ADDRESS
30B. SIGNATURE
29. AWARD (Contractor is not required to sign this document.)
document and return _______ copies to issuing office.) Contractor agrees Your of f er on this solicitation, is hereby accepted as to the items listed. This award con-to f urnish and deliv er all items or perf orm all work, requisitions identif ied summates the contract, which consists of (a) the Gov ernment solicitation and on this f orm and any continuation sheets f or the consideration stated in this y our of f er, and (b) this contract award. No f urther contractual document is contract. The rights and obligations of the parties to this contract shall be necessary .
gov erned by (a) this contract award, (b) the solicitation, and (c) the clauses, representations, certif ications, and specif ications or incorporated by ref er-ence in or attached to this contract.
30A. NAME AND TITLE OF CONTRACTOR OR PERSON AUTHORIZED 31A. NAME OF CONTRACTING OFFICER (Type or print)
30C. DATE
(Type or print)
TEL: EMAIL:
31B. UNITED STATES OF AMERICA 31C. AWARD DATE
BY
CONTRACTING OFFICER WILL COMPLETE ITEM 28 OR 29 AS APPLICABLE
(Contractor is required to sign this28. NEGOTIATED AGREEMENT
(M ust be fully completed by offeror)OFFER
FA2823-11-R-0008
Section B - Supplies or Services and Prices
ITEM NO SUPPLIES/SERVICES MAX
QUANTITY
UNIT UNIT PRICE MAX AMOUNT
0001 12 Months Basic Year, Roofing IDIQ
FFP
Furnish all plant, labor, materials, and equipment, and perform all operations in connection with IDIQ Repair and Replace Roof, Eglin AFB FL in accordance with Specification No. 10BB, dated 06 JAN 2011. SEE SECTION "B"
(SUPPLIES OR SERVICE AND PRICES) FOR SCHEDULE (CLIN 0001
THROUGH CLIN 0182). PERFORMANCE PERIOD IS 365 DAYS FROM
DATE OF AWARD. Reference Specification Section 01 11 00, para 1.7 cost estimating software use of e4Clicks.
FOB: Destination
MAX
NET AMT
UNIT UNIT PRICE MAX AMOUNT
0002 12 Months OPTION Option Year One, Roofing IDIQ
FFP
Furnish all plant, labor, materials, and equipment, and perform all operations in connection with IDIQ Repair and Replace Roof, Eglin AFB FL in accordance with Specification No. 10BB, dated 06 JAN 2011. SEE SECTION "B"
(SUPPLIES OR SERVICE AND PRICES) FOR SCHEDULE (CLIN 1001
THROUGH CLIN 1182). PERFORMANCE PERIOD IS 365 DAYS FROM
THE MODIFICATION EFFECTIVE DATE OF OPTION YEAR ONE.
Reference Specification Section 01 11 00, para 1.7 cost estimating software use of e4Clicks.
UNIT UNIT PRICE MAX AMOUNT
0003 12 Months OPTION Option Year Two, Roofing IDIQ
FFP
Furnish all plant, labor, materials, and equipment, and perform all operations in connection with IDIQ Repair and Replace Roof, Eglin AFB FL in accordance with Specification No. 10BB, dated 06 JAN 2011. SEE SECTION "B"
(SUPPLIES OR SERVICE AND PRICES) FOR SCHEDULE (CLIN 2001
THROUGH CLIN 2182). PERFORMANCE PERIOD IS 365 DAYS FROM
THE MODIFICATION EFFECTIVE DATE OF OPTION YEAR TWO.
Reference Specification Section 01 11 00, para 1.7 cost estimating software use of
UNIT UNIT PRICE MAX AMOUNT
0004 12 Months OPTION Option Year Three, Roofing IDIQ
FFP
Furnish all plant, labor, materials, and equipment, and perform all operations in connection with IDIQ Repair and Replace Roof, Eglin AFB FL in accordance with Specification No. 10BB, dated 06 JAN 2011. SEE SECTION "B"
(SUPPLIES OR SERVICE AND PRICES) FOR SCHEDULE (CLIN 3001
THROUGH CLIN 3182). PERFORMANCE PERIOD IS 365 DAYS FROM
THE MODIFICATION EFFECTIVE DATE OF OPTION YEAR THREE.
Reference Specification Section 01 11 00, para 1.7 cost estimating software use of
ITEM NO
SUPPLIES/SERVICES MAX
QUANTITY
UNIT UNIT PRICE MAX AMOUNT
0005 12 Months OPTION Option Year Four, Roofing IDIQ
FFP
Furnish all plant, labor, materials, and equipment, and perform all operations in connection with IDIQ Repair and Replace Roof, Eglin AFB FL in accordance with Specification No. 10BB, dated 06 JAN 2011. SEE SECTION "B"
(SUPPLIES OR SERVICE AND PRICES) FOR SCHEDULE (CLIN 4001
THROUGH CLIN 4182). PERFORMANCE PERIOD IS 365 DAYS FROM
THE MODIFICATION EFFECTIVE DATE OF OPTION YEAR FOUR.
Reference Specification Section 01 11 00, para 1.7 cost estimating software use of
UNIT UNIT PRICE MAX AMOUNT
0006 6 Months OPTION Option to Extend, Roofing IDIQ
FFP
When exercised the prices for Option to Extend are the same as Option Year Four, in accordance with FAR clause 52.217-8 Option to Extend Services.
Furnish all plant, labor, materials, and equipment, and perform all operations in connection with IDIQ Repair and Replace Roof, Eglin AFB FL in accordance with Specification No. 10BB, dated 06 JAN 2011. SEE SECTION "B"
(SUPPLIES OR SERVICE AND PRICES) FOR SCHEDULE (CLIN 4001
THROUGH CLIN 4182). PERFORMANCE PERIOD IS A MAXIMUM OF 180
DAYS FROM THE APPLICABLE CONTRACT MODIFICATION EFFECTIVE
DATE FOR THE OPTION TO EXTEND. Reference Specification Section 01 11 00, para 1.7 cost estimating software use of e4Clicks.
BID SCHEDULE BASIC YR
Solicitation No. FA2823-11-R-0008 6-Jan-11
PRICE SCHEDULE
EGLIN AFB IDIQ ROOFING
2011-2012
Project No. FTFA 11-1007 Spec. No. 10BB
0.00
BASIC YEAR
LINE
ITEM
DESCRIPTION Unit EST.
QTY.
UNIT
PRICE
EST. TOTAL
PRICE
DIVISION2-SELECTIVE DEMOLITION
REMOVE AND REPLACE EXISTING WOOD BLOCKING,
NAILER, OR FRAMING, NOMINAL 2" THICK, 0-20 BF BF 200
REMOVE AND REPLACE EXISTING WOOD BLOCKING,
NAILER, OR FRAMING, NOMINAL 2" THICK, >20 BF BF 500
0003 REMOVE AND REPLACE WOOD DECKING BF 200
REMOVE AND REPLACE PLYWOOD ROOF
SHEATHING SF 500
REMOVE AND REPLACE EXISTING WOOD FASCIA
BOARDS, NOMINAL 1" THICK, 0-20 BF BF 100
REMOVE AND REPLACE EXISTING WOOD FASCIA
BOARDS, NOMINAL 1" THICK, >20 BF BF 400
REMOVE AND REPLACE EXISTING HARDBOARD
SOFFIT (3/8") SF 100
DIVISION 2-TEAR-OFFS
DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-
PLY BURS WITH FLASHINGS, GRAVEL, ETC. (DOES
NOT INCLUDE INSULATION) SQ 250
DEMOLITION, HAULING, AND DISPOSAL OF
INSULATION UP TO 3" THICK SQ 250
REMOVE AND DISPOSE OF EXISTING ROOF SHINGLE
SYSTEM AND UNDERLAYMENT, INCLUDING
FLASHING AND DRIP EDGES SQ 100
REMOVE AND DISPOSE OF EXISTING ROLL ROOFING
AND UNDERLAYMENT, INCLUDING FLASHING AND
DRIP EDGES SQ 100
DEMOLITION, REMOVAL, AND DISPOSAL OF
EXISTING METAL ROOFING SYSTEM SQ 200
DEMOLITION, HAULING, AND DISPOSAL OF
AGGREGATE BALLAST. INCLUDE SPUDDING BACK
AND VACUUMING LOOSE AGGREGATE FROM ENTIRE
ROOF SURFACE. SQ 200
DEMOLITION, HAULING, AND DISPOSAL OF
AGGREGATE BALLAST ON RESIDENTIAL UNITS AND
PREPARE SURFACE FOR ROLLED ROOFING SQ 200
REMOVE SINGLE PLY ROOFING (INCLUDING PVC,
EPDM, PIB, TPO AND OTHER MEMBRANE ROOFING)
DOWN TO THE DECK. INCLUDE MEMBRANE,
PENETRATION & WALL FLASHINGS AND MEMBRANE
FASTENERS. NOT TO INCLUDE INSULATION,
CRICKETS AND INSULATION FASTENERS.
SQ 50
DIVISION 2-ASBESTOS ABATEMENT
CLASS I AND/OR CLASS II ASBESTOS CONTAINING
ROOF MATERIALS (ACRM) ROOF MEMBRANE. SF 500
CEMENTITIOUS ASBESTOS FIBER ROOF DECK/FORM
BOARD SF 100
DIVISION 4-MASONRY
WATER BLAST CLEAN EXISTING MASONRY
SURFACE IN ACCOURDANCE WITH PAINT
MANUFACTURER'S RECOMMENDATIONS. SF 200
CONCRETE MASONRY UNITS TO INCLUDE
GROUTING, TUCK POINTING, FORMWORK, AND
SUPPORTS. PERFORM WORK IN ACCORDANCE
WITH MANUFACTURER'S RECOMMENDATIONS.
SF 30
DIVISION 5-STEEL ROOF DECK
REMOVE EXISTING STEEL ROOF DECK AND
REPLACE WITH NEW STEEL ROOF DECK SQ 50
DIVISION 5-METALS
COLD-FORMED METAL FRAMING
COLD-FORMED METAL FRAMING MEMBERS OR
SOFFIT FRAMING, TO INCLUDE SADDLES, CANT
STRIPS, CURBS FOR SCUTTLES AND VENTILATORS,
AND NAILERS ATTACHED AT THE TOPS OF
CONCRETE OR MASONRY CURBS, EXPANSION
JOINTS AND ROOF EDGES. FRAMING MEMBERS ARE
4" TO 8" WIDE BY 18 GAUGE OR THINNER. LF 100
RETROFIT SUB-PURLIN AND/OR FORMED SHAPED
FRAMING SYSTEM MECHANICALLY FASTENED TO
EXISTING AND/OR SUBSTRATE IN ACCORDANCE
WITH MANUFACTURES SPECIFICATIONS. MINIMUM
16 GAUGE THICKNESS LF 1000
METAL FABRICATION
SHOP PRIMED STEEL MATERIALS INCLUDING BUT
NOT LIMITED TO: PLATES, ANGLES, ANCHOR BOLTS,
STEEL PIPE SLEEVES, WEDGE TYPE INSERTS,
EXPANSION ANCHORS, FRAMING, SUPPORTS AND
FABRICATED ITEMS FOR APPLICATIONS THAT ARE
NOT SPECIFIED IN OTHER SPECIFICATION
SECTIONS. LB 50
PIPE AND TUBE RAILINGS
FABRICATE AND INSTALL A SIDE OR BASE MOUNT
ALUMINUM PIPE AND/OR TUBE GUARDRAIL SYSTEM LF 12
STAINLESS STEEL PIPE AND/OR TUBE GUARDRAIL
SYSTEM LF 12
FABRICATE AND INSTALL A SIDE OR BASE MOUNT
GALVANIZED STEEL PIPE AND/OR TUBE GUARDRAIL
SYSTEM LF 12
REMOVE AND DISPOSE OF AREAS OF
DETERIORATED OR DAMAGED PIPE AND/OR TUBE
GUARDRAIL SYSTEM LF 20
DIVISION 6-ROUGH CARPENTRY
FURNISH AND INSTALL PRESERVATIVE TREATED
WOOD ROOF NAILERS, WHICH INCLUDES WOOD
SADDLES OR CRICKETS, CANT STRIPS, CURBS FOR
SCUTTLES AND VENTILATORS, AND WOOD NAILERS
BOLTED TO TOPS OF CONCRETE OR MASONRY
CURBS AND AT EXPANSION JOINTS BF 50
REMOVE AND REPLACE 3/8", 5/8"OR 3/4" ROOF
SHEATHING OR SOFFIT ON RESIDENTIAL UNITS SF 500
REMOVE AND REPLACE ROOF DECKING FOR
RESIDENTIAL UNITS, WHICH INCLUDES 1x OR 2x
DECKING SF 200
FURNISH AND INSTALL ROOFING LUMBER FOR
RESIDENTIAL UNITS, WHICH INCLUDES RAFTERS,
STUDS, PLATES, CAPS, COLLAR BEAMS, SLEEPERS,
NAILING STRIPS, SILLS, HEADERS AND FASCIA BF 200
DIVISION 7-INSULATION
POLYISOCYANURATE BOARD INSULATION
0032 1" THICK, R6.5 SQ 100
0033 2" THICK, R13 SQ 100
0034 3" THICK, R19 SQ 100
0035 4" THICK, R30 SQ 2,000
PERLITE BOARD INSULATION, 3/4" THICK, R2.08
0036 <=100 SQ SQ 100
0037 > 100 SQ SQ 500
0038 BATT ROOF INSULATION, R-19 SF 1,000
0039 METAL ROOF INSULATION, R30 SQ 200
0040 FIBER CANTS LF 1,000
0041 WOOD CANTS LF 1,000
0042 TAPERED FILL INSULATION BOARD BF
10,00
0043 TAPERED 1/4" PER FOOT FOR DRAINAGE BF
10,00
DIVISION 7-SHINGLE ROOFING SYSTEMS
FURNISH AND INSTALL NEW MINERAL SURFACED
FIBERGLASS STRIP SHINGLE SYSTEM INCLUDING
UNDERLAYMENT SQ 300
FURNISH AND INSTALL NEW ARCHITECTURAL
DIMENSIONAL FIBERGLASS SHINGLE SYSTEM
INCLUDING UNDERLAYMENT SQ 100
REMOVE AND REPLACE EXISTING SHINGLES WITH
NEW FIBERGLASS STRIP SHINGLES TO MATCH
ADJACENT AREAS, PARTIAL REPAIRS SQ 10
ADD FOR STEEP ROOFS (7 TO 12 PITCH OR
GREATER) SQ 50
0048 FELT, GLASS FIBER, 15 POUND ORGANIC SQ 20
0049 FELT, GLASS FIBER, 30 POUND ORGANIC SQ 10
DIVISION 7-BITUMINOUS ROOFING (BURS)
0050 4-PLY BURS USING ASPHALT SQ 250
0051 4-PLY BURS USING COAL TAR SQ 20
0052 4-PLY BURS WITH SBS MODIFIED CAP SHEET SQ 2000
4-PLY BURS WITH SBS MODIFIED CAP SHEET WITH
ENERGY STAR RATED COATED SQ 1000
FOR RESIDENTIAL UNITS
SINGLE-PLY SBS MODIFIED CAP SHEET FOR
RESIDENTIAL UNITS SQ 250
0055 REMOVE AND REPLACE PITCH PAN EA 30
DIVISION 7-PARTIAL BURS REPAIRS
0056 REPAIRS BLISTERS SF 500
0057 REPAIR SPLITS LF 200
0058 REPAIR RIDGES LF 200
APPLY RESATURANT AND INSTALL NEW
AGGREGATE ON EXPOSED FELT AREAS SF 500
DIVISION 7-PREPARED ROLL ROOFING
FIBERGLASS PREPARED ROLL ROOFING INCLUDING
UNDERLAYMENT SQ 50
0061 CUT-OUT AND PATCH ROLL ROOFING SQ 5
DIVISION 7-POLYVINYL-CHLORIDE ROOFING
FURNISH/INSTALL FULLY ADHERED PVC SYSTEM- 48
MILS SQ 50
FURNISH/INSTALL FULLY ADHERED PVC SYSTEM- 72
MILS SQ 50
FURNISH/INSTALL MECHANICALLY FASTENED PVC
SYSTEM- 60MILS SQ 50
FURNISH/INSTALL MECHANICALLY FASTENED PVC
SYSTEM- 72 MIL SQ 50
PVC LAMINATED METAL FLASHING UP TO 18"
STRETCH OUT LF 100
PVC LAMINATED METAL FLASHING 18.1" TO 36"
STRETCH OUT LF 100
0068 PVC VENT BOOTS EA 5
0069 PVC UNIVERSAL CORNERS EA 50
0070 PATCH AND REPAIR PVC SYSTEM SF 5
DIVISION 7-THERMOPLASTIC POLYOLEFIN ROOFING
FURNISH/INSTALL FULLY ADHERED TPO SYSTEM- 45
MILS SQ 10
FURNISH/INSTALL FULLY ADHERED TPO SYSTEM- 60
MILS SQ 10
FURNISH/INSTALL MECHANICALLY FASTENED TPO
SYSTEM- 45MILS SQ 20
FURNISH/INSTALL MECHANICALLY FASTENED TPO
SYSTEM - 60 MIL SQ 2000
TPO LAMINATED METAL FLASHING UP TO 18"
STRETCH OUT LF 25
TPO LAMINATED METAL FLASHING 18.1" TO 36"
STRETCH OUT LF 25
0077 TPO VENT BOOTS EA 5
0078 TPO UNIVERSAL CORNERS EA 20
0079 PATCH AND REPAIR TPO SYSTEM SF 5
DIVISION 7-FLUID APPLIED WATERPROOFING
FLUID APPLIED COATING SYSTEM FOR METAL
ROOFS SQ 10
ENERGY STAR RATED COATING SYSTEM APPLIED
TO NEW BUR ROOFING WITH MODIFIED CAP SHEET SQ 50
0082 ELASTOMERIC COATING FOR ROOF REPAIRS SQ 10
DIVISION 7-TRAFFIC-BEARING ROOF DECK
SURFACING
0083 TRAFFIC-BEARING ROOF DECK SURFACING SYSTEM SQ 10
DIVISION 7-SHEET METAL WORK, GENERAL
FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA
(FACE DIMENSION)
0084 GALVANIZED METAL, 4"- 5" LF 500
0085 GALVANIZED METAL, 6" - 7" LF 100
0086 ALUMINUM, 4" - 5" LF 500
0087 ALUMINUM, 6" - 7" LF 100
0088 COPPER, 4" - 5" LF 25
0089 COPPER, 6" -7" LF 25
0090 2-PIECE GALVANIZED METAL, 7" - 10" LF 50
0091 2-PIECE GALVANIZED METAL, 10" - 12" LF 50
0092 2-PIECE ALUMINUM, 7" - 10" LF 50
0093 2-PIECE ALUMINUM, 10" - 12" LF 50
0094 2-PIECE COPPER, 7" - 10" LF 50
0095 2-PIECE COPPER, 10" - 12" LF 50
FURNISH AND INSTALL:
0096 GALVANIZED METAL DRIP EDGE LF 200
0097 GALVANIZED METAL COUNTERFLASHING SF 100
0098 GALVANIZED METAL VALLEY FLASHING SF 100
0099 GALVANIZED METAL STEP FLASHING SF 100
0100 GALVANIZED METAL BASE FLASHING SF 100
0101 GALVANIZED METAL FLASHING- FLAT SHEET SF 100
0102 GALVANIZED METAL CAP FLASHING SF 100
0103 ALUMINUM DRIP EDGE LF 200
0104 ALUMINUM COUNTERFLASHING SF 100
0105 ALUMINUM VALLEY FLASHING SF 100
0106 ALUMINUM STEP FLASHING SF 100
0107 ALUMINUM BASE FLASHING SF 100
0108 ALUMINUM FLASHING - FLAT SHEET SF 100
0109 ALUMINUM CAP FLASHING SF 100
0110 METAL RIDGE VENT LF 100
REMOVE EXISTING EXPANSION JOINT AND INSTALL
NEW EXPANSION JOINT:
0111 ELASTOMERIC TYPE (NEOPRENE BELLOWS) LF 100
0112 ALUMINUM CAPPED CURB LF 100
0113 GALVANIZED CAPPED CURB LF 100
0114 REMOVE AND REPLACE VENTILATOR, ROOFTOP EA 1
0115 REMOVE AND REPLACE VENTILATOR, RIDGE LF 40
0116 REMOVE AND REPLACE VENTILATOR, GABLE EA 2
REMOVE AND REPLACE CURB ASSEMBLY, METAL
WITH CRICKET, FACTORY FABRICATED AND
FINISHED EA 2
0118 REMOVE AND REPLACE ROOF SCUTTLE EA 1
DIVISION 7-METAL WALL PANELS
0119 FURNISH AND INSTALL STEEL WALL PANELS SF 100
DIVISION 7-GUTTERS AND DOWNSPOUTS
0120 REMOVE EXISTING GUTTER AND DOWNSPOUTS LF 100
FURNISH AND INSTALL NEW GUTTER, BOX,
INCLUDING HANGARS, BRACKETS, SEALANTS, ETC.
0121 24 GA. GALVANIZED/PRIMED, 4" X 5" LF 500
0122 24 GA. GALVANIZED/PRIMED, 5" X 7" LF 500
0123 ALUMINUM, 4" X 5" LF 100
0124 ALUMINUM, 5" X 7" LF 100
0125 16 OZ. COPPER, 4" X 5" LF 50
0126 16 OZ. COPPER, 5" X 7" LF 50
FURNISH & INSTALL NEW DOWNSPOUTS, INCLUDES
BRACKETS, ETC.
0127 24 GA. GALVANIZED/PRIMED, 3" X 4" LF 500
0128 ALUMINUM, 3" X 4" LF 100
0129 16 OZ. COPPER, 3" X 4" LF 100
FURNISH & INSTALL NEW PRE-FORMED CONCRETE
SPLASHBLOCKS EA 20
DIVISION 7-MANUFACTURED ROOF FRAMING
SYSTEM
RETROFIT ROOFING & STRUCTURAL-UP TO 6/12
SLOPE <= 100 SQ SQ 150
SLOPE =>100 SQ SQ 150
DIVISION 7-STANDING SEAM METAL ROOF SYSTEM
NEW STANDING SEAM METAL ROOF SYSTEM,
STRUCTURAL<=100SQ SQ 150
NEW STANDING SEAM METAL ROOF SYSTEM,
STRUCTURAL, >100SQ SQ 6085
NEW HIGH PERFORMANCE STANDING SEAM METAL
ROOF SYSTEM, STRUCTURAL, WITH INSPECTIONS
AND WARRANTY PER SPEC NO. 07 41 20 SQ 150
NEW STANDING SEAM METAL ROOF SYSTEM,
ARCHITECTURAL SQ 150
0137 FASCIA PANEL SYSTEM SF 1,000
0138 NON-PERFORATED SOFFIT PANEL SF 500
0139 PERFORATED SOFFIT PANEL SF 500
DIVISION 7-CAULKING AND SEALANTS
0140 REMOVE EXISTING CAULKING, CLEAN JOINT LF 150
0141 SILICONE CAULKING/SEALANT LF 150
CAULKING, MISCELLANEOUS APPLICATION
(SONNEBORN, SONOLASTIC NP-1, OR APPROVED
EQUAL) LF 150
DIVISION 9-PAINTING
0143 PAINT, BASE SCHEME, EXT. LATEX, 1 COAT SF 1,000
PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2
COATS SF 1,000
DIVISION 15-ROOF DRAINS
REFLASH EXISTING ROOF DRAIN, INCLUDES NEW
LEAD FLASHING, CLAMPING RING, AND CAST IRON
DOME STRAINER EA 5
REMOVE AND REPLACE EXISTING ROOF DRAIN,
INCLUDES NEW CAST IRON DOME STRAINER EA 20
DIVISION 16-LIGHTING PROTECTION
REMOVE EXISTING LIGHTNING PROTECTION
SYSTEM AND REINSTALL EXISTING LIGHTNING
PROTECTION SYSTEM WITH NEW FASTENERS
0147 REMOVE AND REINSTALL EXISTING CONDUCTOR LF 250
REMOVE AND INSTALL NEW FASTENERS,
INCLUDING LOOPS AND CLIPS EA 25
SYSTEM AND INSTALL NEW LIGHTNING
PROTECTION SYSTEM
AIR TERMINALS, INCLUDES COPPER BASE FOR NON-
METAL ROOFS EA 20
AIR TERMINALS, INCLUDES ALUMINUM BASE FOR
METAL ROOFS EA 20
0151 CONDUCTORS LF 300
0152 FASTENERS, INCLUDES LOOPS AND CLIPS EA 100
0153 CONNECTORS EA 20
0154 COUNTERPOISE CONDUCTOR LF 1000
0155 GROUNDING RODS, 3/4" DIAMETER x 60' LONG EA 10
0156 SURGE PROTECTION EA 1
FURNISH AND INSTALL GROUND ACCESS PVC TEST
WELL, 12" I.D. X 24" LONG WITH 1/4" GALVANIZED
FRICTION FIT COVER WITH THE WORD "GROUND"
ENGREAVED ON TOP OF THE COVER EA 10
0158 UL SITE INSPECTION EA 1
MISCELLANEOUS ROOFING ITEMS
0159 EXTEND PLUMBING VENTS LF 40
0160 FLEXIBLE VENT PIPE FLASHING (METAL ROOFS) EA 30
REMOVE AND REPLACE LEAD FLASHING AT VENT
THRU ROOF (VTR) EA 40
REMOVE EXISTING VTR PENETRATION FLASHING
AND REPLACE WITH COLLAR TYPE FLASHING EA 20
REPAIR AND REPLACE SPALLS, HOLES, AND
CRACKS IN EXISTING CONCRETE ROOF DECK SF 50
FURNISH AND INSTALL VAPOR BARRIER OVER
CONCRETE DECKS SQ 50
FURNISH AND INSTALL ROSIN PAPER OVER WOOD
DECKS SQ 50
DISCONNECT AND RECONNECT ELECTRICAL
SERVICE (<200 AMP) EA 1
REMOVE EXISTING CONDUIT, ETC. AND REPLACE
WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE,
BOXES, FITTINGS, ETC. LF 10
0168 ROLL COIL RIDGE VENT LF 10
0169 60MIL WATERPROOF UNDERLAYMENT LF 150
0170 SPUD EXISTING ROOF TO INSULATION SF 10
0171 CUT AND PATCH CONCRETE LF 1000
0172 TRENCH AND BACKFILL LF 1000
0173 12"x30" CONCRETE SPLASH BLOCKS EA 1
0174 TESTING (CORE CUT) OF ROOFS-REPAIR TEST AREA EA 1
0175 THERMAL IMAGING SURVEY OF ROOF SF 1
0176 AS-BUILT DRAWING PER SPEC. NO. 01 11 00 EA 1
0177 ENGINEERING RATE STRUCTURAL HR 1
0178 MECHANICAL SUBCONTRACTOR HR 1
0179 ELECTRICAL SUBCONTRACTOR HR 1
0180 LABOR RATE - MISCELLANEOUS WORK MH 1
SPECIAL CONDITIONS AND CIRCUMSTANCES
HEIGHT FACTOR, 30 FEET OR GREATER ABOVE
GROUND, UNIT EACH=JOB EA 2
Subtotal
MODIFIERS
MULTIPLIER OF A NOT TO EXCEED 35% TO BE
ADDED TO TOTAL FOR URGENT DELIVERY ORDER
(UDO) -TEMPORARY DRY-IN WORK ONLY %
BASE YEAR TOTAL
BID SCHEDULE OPT YR ONE
PRICE SCHEDULE
EGLIN AFB IDIQ ROOFING
2012-2013
OPTION YEAR ONE
ITE
M
DESCRIPTION Unit EST.
QTY.
UNIT
PRICE
EST.
TOTAL
REMOVE AND REPLACE EXISTING WOOD
BLOCKING, NAILER, OR FRAMING, NOMINAL 2"
THICK, 0-20 BF BF 200
REMOVE AND REPLACE EXISTING WOOD
BLOCKING, NAILER, OR FRAMING, NOMINAL 2"
THICK, >20 BF BF 500
1003 REMOVE AND REPLACE WOOD DECKING BF 200
REMOVE AND REPLACE PLYWOOD ROOF
SHEATHING SF 500
REMOVE AND REPLACE EXISTING WOOD FASCIA
BOARDS, NOMINAL 1" THICK, 0-20 BF BF 100
REMOVE AND REPLACE EXISTING WOOD FASCIA
BOARDS, NOMINAL 1" THICK, >20 BF BF 400
DEMOLITION, HAULING, AND DISPOSAL OF UP TO
5-PLY BURS WITH FLASHINGS, GRAVEL, ETC.
(DOES NOT INCLUDE INSULATION) SQ 250
DEMOLITION, HAULING, AND DISPOSAL OF
INSULATION UP TO 3" THICK SQ 250
REMOVE AND DISPOSE OF EXISTING ROOF
SHINGLE SYSTEM AND UNDERLAYMENT,
INCLUDING FLASHING AND DRIP EDGES SQ 100
REMOVE AND DISPOSE OF EXISTING ROLL
ROOFING AND UNDERLAYMENT, INCLUDING
FLASHING AND DRIP EDGES SQ 100
DEMOLITION, REMOVAL, AND DISPOSAL OF
EXISTING METAL ROOFING SYSTEM SQ 200
DEMOLITION, HAULING, AND DISPOSAL OF
AGGREGATE BALLAST. INCLUDE SPUDDING BACK
AND VACUUMING LOOSE AGGREGATE FROM
ENTIRE ROOF SURFACE. SQ 200
AGGREGATE BALLAST ON RESIDENTIAL UNITS
AND PREPARE SURFACE FOR ROLLED ROOFING SQ 200
REMOVE SINGLE PLY ROOFING (INCLUDING PVC,
EPDM, PIB, TPO AND OTHER MEMBRANE
ROOFING) DOWN TO THE DECK. INCLUDE
MEMBRANE, PENETRATION & WALL FLASHINGS
AND MEMBRANE FASTENERS. NOT TO INCLUDE
INSULATION, CRICKETS AND INSULATION
FASTENERS. SQ 50
ROOF MATERIALS (ACRM) ROOF MEMBRANE. SF 500
CEMENTITIOUS ASBESTOS FIBER ROOF
DECK/FORM BOARD SF 100
SURFACE IN ACCOURDANCE WITH PAINT
MANUFACTURER'S RECOMMENDATIONS. SF 200
CONCRETE MASONRY UNITS TO INCLUDE
GROUTING, TUCK POINTING, FORMWORK, AND
SUPPORTS. PERFORM WORK IN ACCORDANCE
SOFFIT FRAMING, TO INCLUDE SADDLES, CANT
STRIPS, CURBS FOR SCUTTLES AND
VENTILATORS, AND NAILERS ATTACHED AT THE
TOPS OF CONCRETE OR MASONRY CURBS,
EXPANSION JOINTS AND ROOF EDGES. FRAMING
MEMBERS ARE 4" TO 8" WIDE BY 18 GAUGE OR
THINNER. LF 100
RETROFIT SUB-PURLIN AND/OR FORMED SHAPED
FRAMING SYSTEM MECHANICALLY FASTENED TO
EXISTING AND/OR SUBSTRATE IN ACCORDANCE
WITH MANUFACTURES SPECIFICATIONS. MINIMUM
16 GAUGE THICKNESS LF 1000
METAL FABRICATION
SHOP PRIMED STEEL MATERIALS INCLUDING BUT
NOT LIMITED TO: PLATES, ANGLES, ANCHOR
BOLTS, STEEL PIPE SLEEVES, WEDGE TYPE
INSERTS, EXPANSION ANCHORS, FRAMING,
SUPPORTS AND FABRICATED ITEMS FOR
APPLICATIONS THAT ARE NOT SPECIFIED IN
OTHER SPECIFICATION SECTIONS. LB 50
PIPE AND TUBE RAILINGS
ALUMINUM PIPE AND/OR TUBE GUARDRAIL LF 12
FABRICATE AND INSTALL A SIDE OR BASE MOUNT
STAINLESS STEEL PIPE AND/OR TUBE GUARDRAIL
SYSTEM LF 12
FABRICATE AND INSTALL A SIDE OR BASE MOUNT
GALVANIZED STEEL PIPE AND/OR TUBE
GUARDRAIL SYSTEM LF 12
REMOVE AND DISPOSE OF AREAS OF
WOOD ROOF NAILERS, WHICH INCLUDES WOOD
SADDLES OR CRICKETS, CANT STRIPS, CURBS
FOR SCUTTLES AND VENTILATORS, AND WOOD
NAILERS BOLTED TO TOPS OF CONCRETE OR
MASONRY CURBS AND AT EXPANSION JOINTS BF 50
REMOVE AND REPLACE 3/8", 5/8"OR 3/4" ROOF
SHEATHING OR SOFFIT ON RESIDENTIAL UNITS SF 500
REMOVE AND REPLACE ROOF DECKING FOR
RESIDENTIAL UNITS, WHICH INCLUDES 1x OR 2x
DECKING SF 200
FURNISH AND INSTALL ROOFING LUMBER FOR
RESIDENTIAL UNITS, WHICH INCLUDES RAFTERS,
STUDS, PLATES, CAPS, COLLAR BEAMS,
SLEEPERS, NAILING STRIPS, SILLS, HEADERS AND
FASCIA BF 200
1032 1" THICK, R6.5 SQ 100
1033 2" THICK, R13 SQ 100
1034 3" THICK, R19 SQ 100
1035 4" THICK, R30 SQ 2000
1036 <=100 SQ SQ 100
1037 > 100 SQ SQ 500
1038 BATT ROOF INSULATION, R-19 SF 1000
1039 METAL ROOF INSULATION, R30 SQ 200
1040 FIBER CANTS LF 1000
1041 WOOD CANTS LF 1000
1042 TAPERED FILL INSULATION BOARD BF 10000
1043 TAPERED 1/4" PER FOOT FOR DRAINAGE BF 10000
DIMENSIONAL FIBERGLASS SHINGLE SYSTEM
INCLUDING UNDERLAYMENT SQ 100
REMOVE AND REPLACE EXISTING SHINGLES WITH
NEW FIBERGLASS STRIP SHINGLES TO MATCH
ADJACENT AREAS, PARTIAL REPAIRS SQ 10
ADD FOR STEEP ROOFS (7 TO 12 PITCH OR
GREATER) SQ 50
1048 FELT, GLASS FIBER, 15 POUND ORGANIC SQ 20
1049 FELT, GLASS FIBER, 30 POUND ORGANIC SQ 10
1050 4-PLY BURS USING ASPHALT SQ 250
1051 4-PLY BURS USING COAL TAR SQ 20
1052 4-PLY BURS WITH SBS MODIFIED CAP SHEET SQ 2000
1055 REMOVE AND REPLACE PITCH PAN EA 30
1056 REPAIRS BLISTERS SF 500
1057 REPAIR SPLITS LF 200
1058 REPAIR RIDGES LF 200
FIBERGLASS PREPARED ROLL ROOFING
INCLUDING UNDERLAYMENT SQ 50
1061 CUT-OUT AND PATCH ROLL ROOFING SQ 5
FURNISH/INSTALL FULLY ADHERED PVC SYSTEM-
48 MILS SQ 50
FURNISH/INSTALL FULLY ADHERED PVC SYSTEM-
72 MILS SQ 50
FURNISH/INSTALL MECHANICALLY FASTENED PVC
SYSTEM- 60MILS SQ 50
FURNISH/INSTALL MECHANICALLY FASTENED PVC
SYSTEM- 72 MIL SQ 50
PVC LAMINATED METAL FLASHING UP TO 18"
STRETCH OUT LF 100
PVC LAMINATED METAL FLASHING 18.1" TO 36"
STRETCH OUT LF 100
1068 PVC VENT BOOTS EA 5
1069 PVC UNIVERSAL CORNERS EA 50
1070 PATCH AND REPAIR PVC SYSTEM SF 5
DIVISION 7-THERMOPLASTIC POLYOLEFIN
ROOFING
FURNISH/INSTALL FULLY ADHERED TPO SYSTEM-
45 MILS SQ 10
FURNISH/INSTALL FULLY ADHERED TPO SYSTEM-
60 MILS SQ 10
FURNISH/INSTALL MECHANICALLY FASTENED TPO
SYSTEM- 45MILS SQ 20
FURNISH/INSTALL MECHANICALLY FASTENED TPO
SYSTEM - 60 MIL SQ 2000
TPO LAMINATED METAL FLASHING UP TO 18"
STRETCH OUT LF 25
TPO LAMINATED METAL FLASHING 18.1" TO 36"
STRETCH OUT LF 25
1077 TPO VENT BOOTS EA 5
1078 TPO UNIVERSAL CORNERS EA 20
1079 PATCH AND REPAIR TPO SYSTEM SF 5
ROOFS SQ 10
ENERGY STAR RATED COATING SYSTEM APPLIED
TO NEW BUR ROOFING WITH MODIFIED CAP
SHEET SQ 50
1082 ELASTOMERIC COATING FOR ROOF REPAIRS SQ 10
TRAFFIC-BEARING ROOF DECK SURFACING
SYSTEM SQ 10
FURNISH AND INSTALL NEW GRAVEL
GUARD/FASCIA (FACE DIMENSION)
1084 GALVANIZED METAL, 4"- 5" LF 500
1085 GALVANIZED METAL, 6" - 7" LF 100
1086 ALUMINUM, 4" - 5" LF 500
1087 ALUMINUM, 6" - 7" LF 100
1088 COPPER, 4" - 5" LF 25
1089 COPPER, 6" -7" LF 25
1090 2-PIECE GALVANIZED METAL, 7" - 10" LF 50
1091 2-PIECE GALVANIZED METAL, 10" - 12" LF 50
1092 2-PIECE ALUMINUM, 7" - 10" LF 50
1093 2-PIECE ALUMINUM, 10" - 12" LF 50
1094 2-PIECE COPPER, 7" - 10" LF 50
1095 2-PIECE COPPER, 10" - 12" LF 50
FURNISH AND INSTALL:
1096 GALVANIZED METAL DRIP EDGE LF 200
1097 GALVANIZED METAL COUNTERFLASHING SF 100
1098 GALVANIZED METAL VALLEY FLASHING SF 100
1099 GALVANIZED METAL STEP FLASHING SF 100
1100 GALVANIZED METAL BASE FLASHING SF 100
1101 GALVANIZED METAL FLASHING- FLAT SHEET SF 100
1102 GALVANIZED METAL CAP FLASHING SF 100
1103 ALUMINUM DRIP EDGE LF 200
1104 ALUMINUM COUNTERFLASHING SF 100
1105 ALUMINUM VALLEY FLASHING SF 100
1106 ALUMINUM STEP FLASHING SF 100
1107 ALUMINUM BASE FLASHING SF 100
1108 ALUMINUM FLASHING - FLAT SHEET SF 100
1109 ALUMINUM CAP FLASHING SF 100
1110 METAL RIDGE VENT LF 100
REMOVE EXISTING EXPANSION JOINT AND
INSTALL NEW EXPANSION JOINT:
1111 ELASTOMERIC TYPE (NEOPRENE BELLOWS) LF 100
1112 ALUMINUM CAPPED CURB LF 100
1113 GALVANIZED CAPPED CURB LF 100
1114 REMOVE AND REPLACE VENTILATOR, ROOFTOP EA 1
1115 REMOVE AND REPLACE VENTILATOR, RIDGE LF 40
1116 REMOVE AND REPLACE VENTILATOR, GABLE EA 2
REMOVE AND REPLACE CURB ASSEMBLY, METAL
WITH CRICKET, FACTORY FABRICATED AND
1118 REMOVE AND REPLACE ROOF SCUTTLE EA 1
1119 FURNISH AND INSTALL STEEL WALL PANELS SF 100
1120 REMOVE EXISTING GUTTER AND DOWNSPOUTS LF 100
INCLUDING HANGARS, BRACKETS, SEALANTS,
ETC.
1121 24 GA. GALVANIZED/PRIMED, 4" X 5" LF 500
1122 24 GA. GALVANIZED/PRIMED, 5" X 7" LF 500
1123 ALUMINUM, 4" X 5" LF 100
1124 ALUMINUM, 5" X 7" LF 100
1125 16 OZ. COPPER, 4" X 5" LF 50
1126 16 OZ. COPPER, 5" X 7" LF 50
FURNISH & INSTALL NEW DOWNSPOUTS,
INCLUDES BRACKETS, ETC.
1127 24 GA. GALVANIZED/PRIMED, 3" X 4" LF 500
1128 ALUMINUM, 3" X 4" LF 100
1129 16 OZ. COPPER, 3" X 4" LF 100
FURNISH & INSTALL NEW PRE-FORMED
CONCRETE SPLASHBLOCKS EA 20
SLOPE <= 100 SQ SQ 150
DIVISION 7-STANDING SEAM METAL ROOF
STRUCTURAL<=100SQ SQ 150
NEW STANDING SEAM METAL ROOF SYSTEM,
STRUCTURAL, >100SQ SQ 5575
NEW HIGH PERFORMANCE STANDING SEAM
METAL ROOF SYSTEM, STRUCTURAL, WITH
INSPECTIONS AND WARRANTY PER SPEC NO. 07
41 20 SQ 150
NEW STANDING SEAM METAL ROOF SYSTEM,
ARCHITECTURAL SQ 150
1137 FASCIA PANEL SYSTEM SF 1000
1138 NON-PERFORATED SOFFIT PANEL SF 500
1139 PERFORATED SOFFIT PANEL SF 500
1140 REMOVE EXISTING CAULKING, CLEAN JOINT LF 150
1141 SILICONE CAULKING/SEALANT LF 150
CAULKING, MISCELLANEOUS APPLICATION
1143 PAINT, BASE SCHEME, EXT. LATEX, 1 COAT LF 1000
COATS LF 1000
LEAD FLASHING, CLAMPING RING, AND CAST IRON
DOME STRAINER EA 5
1147 REMOVE AND REINSTALL EXISTING CONDUCTOR LF 250
PROTECTION SYSTEM
AIR TERMINALS, INCLUDES COPPER BASE FOR
NON-METAL ROOFS EA 20
AIR TERMINALS, INCLUDES ALUMINUM BASE FOR
METAL ROOFS EA 20
1151 CONDUCTORS LF 300
1152 FASTENERS, INCLUDES LOOPS AND CLIPS EA 100
1153 CONNECTORS EA 20
1154 COUNTERPOISE CONDUCTOR LF 1000
1155 GROUNDING RODS, 3/4" DIAMETER x 60' LONG EA 10
1156 SURGE PROTECTION EA 1
FURNISH AND INSTALL GROUND ACCESS PVC
TEST WELL, 12" I.D. X 24" LONG WITH 1/4"
GALVANIZED FRICTION FIT COVER WITH THE
WORD "GROUND" ENGREAVED ON TOP OF THE
COVER EA 10
1158 UL SITE INSPECTION EA 1
1159 EXTEND PLUMBING VENTS LF 40
1160 FLEXIBLE VENT PIPE FLASHING (METAL ROOFS) EA 30
REMOVE AND REPLACE LEAD FLASHING AT VENT
THRU ROOF (VTR) EA 40
REMOVE EXISTING VTR PENETRATION FLASHING
AND REPLACE WITH COLLAR TYPE FLASHING EA 20
REPAIR AND REPLACE SPALLS, HOLES, AND
CRACKS IN EXISTING CONCRETE ROOF DECK SF 50
FURNISH AND INSTALL VAPOR BARRIER OVER
CONCRETE DECKS SQ 50
FURNISH AND INSTALL ROSIN PAPER OVER WOOD
DECKS SQ 50
DISCONNECT AND RECONNECT ELECTRICAL
SERVICE (<200 AMP) EA 1
REMOVE EXISTING CONDUIT, ETC. AND REPLACE
WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE,
BOXES, FITTINGS, ETC. LF 10
1168 ROLL COIL RIDGE VENT LF 10
1169 60MIL WATERPROOF UNDERLAYMENT LF 150
1170 SPUD EXISTING ROOF TO INSULATION SF 10
1171 CUT AND PATCH CONCRETE LF 1000
1172 TRENCH AND BACKFILL LF 1000
1173 12"x30" CONCRETE SPLASH BLOCKS EA 1
TESTING (CORE CUT) OF ROOFS-REPAIR TEST
AREA EA 1
1175 THERMAL IMAGING SURVEY OF ROOF SF 1
1176 AS-BUILT DRAWING PER SPEC. NO. 01 11 00 EA 1
1177 ENGINEERING RATE STRUCTURAL HR 1
1178 MECHANICAL SUBCONTRACTOR HR 1
1179 ELECTRICAL SUBCONTRACTOR HR 1
1180 LABOR RATE - MISCELLANEOUS WORK MH 1
OPTION YEAR ONE TOTAL
BID SCHEDULE OPT YR TWO
PRICE SCHEDULE
EGLIN AFB IDIQ ROOFING
2013-2014
OPTION YEAR TWO
ITE
M
DESCRIPTION Unit EST.
QTY.
UNIT
PRICE
REMOVE AND REPLACE EXISTING WOOD
BLOCKING, NAILER, OR FRAMING, NOMINAL 2"
THICK, 0-20 BF BF 200
REMOVE AND REPLACE EXISTING WOOD
BLOCKING, NAILER, OR FRAMING, NOMINAL 2"
THICK, >20 BF BF 500
2003 REMOVE AND REPLACE WOOD DECKING BF 200
REMOVE AND REPLACE PLYWOOD ROOF
SHEATHING SF 500
REMOVE AND REPLACE EXISTING WOOD FASCIA
BOARDS, NOMINAL 1" THICK, 0-20 BF BF 100
REMOVE AND REPLACE EXISTING WOOD FASCIA
BOARDS, NOMINAL 1" THICK, >20 BF BF 400
DEMOLITION, HAULING, AND DISPOSAL OF UP TO
5-PLY BURS WITH FLASHINGS, GRAVEL, ETC.
(DOES NOT INCLUDE INSULATION) SQ 250
DEMOLITION, HAULING, AND DISPOSAL OF
INSULATION UP TO 3" THICK SQ 250
REMOVE AND DISPOSE OF EXISTING ROOF
SHINGLE SYSTEM AND UNDERLAYMENT,
INCLUDING FLASHING AND DRIP EDGES SQ 100
REMOVE AND DISPOSE OF EXISTING ROLL
ROOFING AND UNDERLAYMENT, INCLUDING
FLASHING AND DRIP EDGES SQ 100
DEMOLITION, REMOVAL, AND DISPOSAL OF
EXISTING METAL ROOFING SYSTEM SQ 200
DEMOLITION, HAULING, AND DISPOSAL OF
AGGREGATE BALLAST. INCLUDE SPUDDING BACK
AND VACUUMING LOOSE AGGREGATE FROM
ENTIRE ROOF SURFACE. SQ 200
AGGREGATE BALLAST ON RESIDENTIAL UNITS
AND PREPARE SURFACE FOR ROLLED ROOFING SQ 200
REMOVE SINGLE PLY ROOFING (INCLUDING PVC,
EPDM, PIB, TPO AND OTHER MEMBRANE
ROOFING) DOWN TO THE DECK. INCLUDE
MEMBRANE, PENETRATION & WALL FLASHINGS
AND MEMBRANE FASTENERS. NOT TO INCLUDE
INSULATION, CRICKETS AND INSULATION
FASTENERS. SQ 50
ROOF MATERIALS (ACRM) ROOF MEMBRANE. SF 500
CEMENTITIOUS ASBESTOS FIBER ROOF
DECK/FORM BOARD SF 100
SURFACE IN ACCOURDANCE WITH PAINT
MANUFACTURER'S RECOMMENDATIONS. SF 200
CONCRETE MASONRY UNITS TO INCLUDE
GROUTING, TUCK POINTING, FORMWORK, AND
SUPPORTS. PERFORM WORK IN ACCORDANCE
SOFFIT FRAMING, TO INCLUDE SADDLES, CANT
STRIPS, CURBS FOR SCUTTLES AND
VENTILATORS, AND NAILERS ATTACHED AT THE
TOPS OF CONCRETE OR MASONRY CURBS,
EXPANSION JOINTS AND ROOF EDGES. FRAMING
MEMBERS ARE 4" TO 8" WIDE BY 18 GAUGE OR
THINNER. LF 100
RETROFIT SUB-PURLIN AND/OR FORMED SHAPED
FRAMING SYSTEM MECHANICALLY FASTENED TO
EXISTING AND/OR SUBSTRATE IN ACCORDANCE
WITH MANUFACTURES SPECIFICATIONS.
MINIMUM 16 GAUGE THICKNESS LF 1000
METAL FABRICATION
SHOP PRIMED STEEL MATERIALS INCLUDING BUT
NOT LIMITED TO: PLATES, ANGLES, ANCHOR
BOLTS, STEEL PIPE SLEEVES, WEDGE TYPE
INSERTS, EXPANSION ANCHORS, FRAMING,
SUPPORTS AND FABRICATED ITEMS FOR
APPLICATIONS THAT ARE NOT SPECIFIED IN
OTHER SPECIFICATION SECTIONS. LB 50
PIPE AND TUBE RAILINGS
FABRICATE AND INSTALL A SIDE OR BASE MOUNT
ALUMINUM PIPE AND/OR TUBE GUARDRAIL
SYSTEM LF 12
STAINLESS STEEL PIPE AND/OR TUBE GUARDRAIL
SYSTEM LF 12
FABRICATE AND INSTALL A SIDE OR BASE MOUNT
GALVANIZED STEEL PIPE AND/OR TUBE
GUARDRAIL SYSTEM LF 12
REMOVE AND DISPOSE OF AREAS OF
WOOD ROOF NAILERS, WHICH INCLUDES WOOD
SADDLES OR CRICKETS, CANT STRIPS, CURBS
FOR SCUTTLES AND VENTILATORS, AND WOOD
NAILERS BOLTED TO TOPS OF CONCRETE OR
MASONRY CURBS AND AT EXPANSION JOINTS BF 50
REMOVE AND REPLACE 3/8", 5/8"OR 3/4" ROOF
SHEATHING OR SOFFIT ON RESIDENTIAL UNITS SF 500
REMOVE AND REPLACE ROOF DECKING FOR
RESIDENTIAL UNITS, WHICH INCLUDES 1x OR 2x
DECKING SF 200
FURNISH AND INSTALL ROOFING LUMBER FOR
RESIDENTIAL UNITS, WHICH INCLUDES RAFTERS,
STUDS, PLATES, CAPS, COLLAR BEAMS,
SLEEPERS, NAILING STRIPS, SILLS, HEADERS
AND FASCIA BF 200
2032 1" THICK, R6.5 SQ 100
2033 2" THICK, R13 SQ 100
2034 3" THICK, R19 SQ 100
2035 4" THICK, R30 SQ 2000
PERLITE BOARD INSULATION, 3/4" THICK, R2.08
2036 <=100 SQ SQ 100
2037 > 100 SQ SQ 500
2038 BATT ROOF INSULATION, R-19 SF 1000
2039 METAL ROOF INSULATION, R30 SQ 200
2040 FIBER CANTS LF 1000
2041 WOOD CANTS LF 1000
2042 TAPERED FILL INSULATION BOARD BF 10000
2043 TAPERED 1/4" PER FOOT FOR DRAINAGE BF 10000
DIMENSIONAL FIBERGLASS SHINGLE SYSTEM
INCLUDING UNDERLAYMENT SQ 100
REMOVE AND REPLACE EXISTING SHINGLES
WITH NEW FIBERGLASS STRIP SHINGLES TO
MATCH ADJACENT AREAS, PARTIAL REPAIRS SQ 10
ADD FOR STEEP ROOFS (7 TO 12 PITCH OR
GREATER) SQ 50
2048 FELT, GLASS FIBER, 15 POUND ORGANIC SQ 20
2049 FELT, GLASS FIBER, 30 POUND ORGANIC SQ 10
2050 4-PLY BURS USING ASPHALT SQ 250
2051 4-PLY BURS USING COAL TAR SQ 20
2052 4-PLY BURS WITH SBS MODIFIED CAP SHEET SQ 2000
4-PLY BURS WITH SBS MODIFIED CAP SHEET
WITH ENERGY STAR RATED COATED SQ 1000
FOR RESIDENTIAL UNITS
SINGLE-PLY SBS MODIFIED CAP SHEET FOR
2055 REMOVE AND REPLACE PITCH PAN EA 30
2056 REPAIRS BLISTERS SF 500
2057 REPAIR SPLITS LF 200
2058 REPAIR RIDGES LF 200
FIBERGLASS PREPARED ROLL ROOFING
INCLUDING UNDERLAYMENT SQ 50
2061 CUT-OUT AND PATCH ROLL ROOFING SQ 5
FURNISH/INSTALL FULLY ADHERED PVC SYSTEM-
48 MILS SQ 50
FURNISH/INSTALL FULLY ADHERED PVC SYSTEM-
72 MILS SQ 50
FURNISH/INSTALL MECHANICALLY FASTENED PVC
SYSTEM- 60MILS SQ 50
FURNISH/INSTALL MECHANICALLY FASTENED PVC
SYSTEM- 72 MIL SQ 50
PVC LAMINATED METAL FLASHING UP TO 18"
STRETCH OUT LF 100
PVC LAMINATED METAL FLASHING 18.1" TO 36"
STRETCH OUT LF 100
2068 PVC VENT BOOTS EA 5
2069 PVC UNIVERSAL CORNERS EA 50
2070 PATCH AND REPAIR PVC SYSTEM SF 5
DIVISION 7-THERMOPLASTIC POLYOLEFIN
ROOFING
FURNISH/INSTALL FULLY ADHERED TPO SYSTEM-
45 MILS SQ 10
FURNISH/INSTALL FULLY ADHERED TPO SYSTEM-
60 MILS SQ 10
FURNISH/INSTALL MECHANICALLY FASTENED TPO
SYSTEM- 45MILS SQ 20
FURNISH/INSTALL MECHANICALLY FASTENED TPO
SYSTEM - 60 MIL SQ 2000
TPO LAMINATED METAL FLASHING UP TO 18"
STRETCH OUT LF 25
TPO LAMINATED METAL FLASHING 18.1" TO 36"
STRETCH OUT LF 25
2077 TPO VENT BOOTS EA 5
2078 TPO UNIVERSAL CORNERS EA 20
2079 PATCH AND REPAIR TPO SYSTEM SF 5
ROOFS SQ 10
ENERGY STAR RATED COATING SYSTEM APPLIED
TO NEW BUR ROOFING WITH MODIFIED CAP
SHEET SQ 50
2082 ELASTOMERIC COATING FOR ROOF REPAIRS SQ 10
TRAFFIC-BEARING ROOF DECK SURFACING
SYSTEM SQ 10
FURNISH AND INSTALL NEW GRAVEL
GUARD/FASCIA (FACE DIMENSION)
2084 GALVANIZED METAL, 4"- 5" LF 500
2085 GALVANIZED METAL, 6" - 7" LF 100
2086 ALUMINUM, 4" - 5" LF 500
2087 ALUMINUM, 6" - 7" LF 100
2088 COPPER, 4" - 5" LF 25
2089 COPPER, 6" -7" LF 25
2090 2-PIECE GALVANIZED METAL, 7" - 10" LF 50
2091 2-PIECE GALVANIZED METAL, 10" - 12" LF 50
2092 2-PIECE ALUMINUM, 7" - 10" LF 50
2093 2-PIECE ALUMINUM, 10" - 12" LF 50
2094 2-PIECE COPPER, 7" - 10" LF 50
2095 2-PIECE COPPER, 10" - 12" LF 50
2096 GALVANIZED METAL DRIP EDGE LF 200
2097 GALVANIZED METAL COUNTERFLASHING SF 100
2098 GALVANIZED METAL VALLEY FLASHING SF 100
2099 GALVANIZED METAL STEP FLASHING SF 100
2100 GALVANIZED METAL BASE FLASHING SF 100
2101 GALVANIZED METAL FLASHING- FLAT SHEET SF 100
2102 GALVANIZED METAL CAP FLASHING SF 100
2103 ALUMINUM DRIP EDGE LF 200
2104 ALUMINUM COUNTERFLASHING SF 100
2105 ALUMINUM VALLEY FLASHING SF 100
2106 ALUMINUM STEP FLASHING SF 100
2107 ALUMINUM BASE FLASHING SF 100
2108 ALUMINUM FLASHING - FLAT SHEET SF 100
2109 ALUMINUM CAP FLASHING SF 100
2110 METAL RIDGE VENT LF 100
REMOVE EXISTING EXPANSION JOINT AND
INSTALL NEW EXPANSION JOINT:
2111 ELASTOMERIC TYPE (NEOPRENE BELLOWS) LF 100
2112 ALUMINUM CAPPED CURB LF 100
2113 GALVANIZED CAPPED CURB LF 100
2114 REMOVE AND REPLACE VENTILATOR, ROOFTOP EA 1
2115 REMOVE AND REPLACE VENTILATOR, RIDGE LF 40
2116 REMOVE AND REPLACE VENTILATOR, GABLE EA 2
REMOVE AND REPLACE CURB ASSEMBLY, METAL
WITH CRICKET, FACTORY FABRICATED AND
2118 REMOVE AND REPLACE ROOF SCUTTLE EA 1
2119 FURNISH AND INSTALL STEEL WALL PANELS SF 100
2120 REMOVE EXISTING GUTTER AND DOWNSPOUTS LF 100
INCLUDING HANGARS, BRACKETS, SEALANTS,
ETC.
2121 24 GA. GALVANIZED/PRIMED, 4" X 5" LF 500
2122 24 GA. GALVANIZED/PRIMED, 5" X 7" LF 500
2123 ALUMINUM, 4" X 5" LF 100
2124 ALUMINUM, 5" X 7" LF 100
2125 16 OZ. COPPER, 4" X 5" LF 50
2126 16 OZ. COPPER, 5" X 7" LF 50
FURNISH & INSTALL NEW DOWNSPOUTS,
INCLUDES BRACKETS, ETC.
2127 24 GA. GALVANIZED/PRIMED, 3" X 4" LF 500
2128 ALUMINUM, 3" X 4" LF 100
2129 16 OZ. COPPER, 3" X 4" LF 100
FURNISH & INSTALL NEW PRE-FORMED
CONCRETE SPLASHBLOCKS EA 20
SLOPE <= 100 SQ SQ 150
DIVISION 7-STANDING SEAM METAL ROOF
STRUCTURAL<=100SQ SQ 150
NEW STANDING SEAM METAL ROOF SYSTEM,
STRUCTURAL, >100SQ SQ 5095
NEW HIGH PERFORMANCE STANDING SEAM
METAL ROOF SYSTEM, STRUCTURAL, WITH
INSPECTIONS AND WARRANTY PER SPEC NO. 07
41 20 SQ 150
NEW STANDING SEAM METAL ROOF SYSTEM,
ARCHITECTURAL SQ 150
2137 FASCIA PANEL SYSTEM SF 1000
2138 NON-PERFORATED SOFFIT PANEL SF 500
2139 PERFORATED SOFFIT PANEL SF 500
2140 REMOVE EXISTING CAULKING, CLEAN JOINT LF 150
2141 SILICONE CAULKING/SEALANT LF 150
CAULKING, MISCELLANEOUS APPLICATION
2143 PAINT, BASE SCHEME, EXT. LATEX, 1 COAT LF 1000
LEAD FLASHING, CLAMPING RING, AND CAST
IRON DOME STRAINER EA 5
2147 REMOVE AND REINSTALL EXISTING CONDUCTOR LF 250
PROTECTION SYSTEM
AIR TERMINALS, INCLUDES COPPER BASE FOR
NON-METAL ROOFS EA 20
AIR TERMINALS, INCLUDES ALUMINUM BASE FOR
METAL ROOFS EA 20
2151 CONDUCTORS LF 300
2152 FASTENERS, INCLUDES LOOPS AND CLIPS EA 100
2153 CONNECTORS EA 20
2154 COUNTERPOISE CONDUCTOR LF 1000
2155 GROUNDING RODS, 3/4" DIAMETER x 60' LONG EA 10
2156 SURGE PROTECTION EA 1
FURNISH AND INSTALL GROUND ACCESS PVC
TEST WELL, 12" I.D. X 24" LONG WITH 1/4"
GALVANIZED FRICTION FIT COVER WITH THE
WORD "GROUND" ENGREAVED ON TOP OF THE
COVER EA 10
2158 UL SITE INSPECTION EA 1
2159 EXTEND PLUMBING VENTS LF 40
2160 FLEXIBLE VENT PIPE FLASHING (METAL ROOFS) EA 30
REMOVE AND REPLACE LEAD FLASHING AT VENT
THRU ROOF (VTR) EA 40
REMOVE EXISTING VTR PENETRATION FLASHING
AND REPLACE WITH COLLAR TYPE FLASHING EA 20
REPAIR AND REPLACE SPALLS, HOLES, AND
CRACKS IN EXISTING CONCRETE ROOF DECK SF 50
FURNISH AND INSTALL VAPOR BARRIER OVER
CONCRETE DECKS SQ 50
FURNISH AND INSTALL ROSIN PAPER OVER
WOOD DECKS SQ 50
DISCONNECT AND RECONNECT ELECTRICAL
SERVICE (<200 AMP) EA 1
REMOVE EXISTING CONDUIT, ETC. AND REPLACE
WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE,
BOXES, FITTINGS, ETC. LF 10
2168 ROLL COIL RIDGE VENT LF 10
2169 60MIL WATERPROOF UNDERLAYMENT LF 150
2170 SPUD EXISTING ROOF TO INSULATION SF 10
2171 CUT AND PATCH CONCRETE LF 1000
2172 TRENCH AND BACKFILL LF 1000
2173 12"x30" CONCRETE SPLASH BLOCKS EA 1
TESTING (CORE CUT) OF ROOFS-REPAIR TEST
AREA EA 1
2175 THERMAL IMAGING SURVEY OF ROOF SF 1
2176 AS-BUILT DRAWING PER SPEC. NO. 01 11 00 EA 1
2177 ENGINEERING RATE STRUCTURAL HR 1
2178 MECHANICAL SUBCONTRACTOR HR 1
2179 ELECTRICAL SUBCONTRACTOR HR 1
2180 LABOR RATE - MISCELLANEOUS WORK MH 1
OPTION YEAR TWO TOTAL
BID SCHEDULE OPT YR THREE
PRICE SCHEDULE
EGLIN AFB IDIQ ROOFING
2014-2015
OPTION YEAR THREE
ITE
M
DESCRIPTION Unit EST.
QTY.
UNIT
PRICE
NAILER, OR FRAMING, NOMINAL 2" THICK, 0-20 BF BF 200
REMOVE AND REPLACE EXISTING WOOD BLOCKING,
NAILER, OR FRAMING, NOMINAL 2" THICK, >20 BF BF 500
3003 REMOVE AND REPLACE WOOD DECKING BF 200
REMOVE AND REPLACE PLYWOOD ROOF
SHEATHING SF 500
REMOVE AND REPLACE EXISTING WOOD FASCIA
BOARDS, NOMINAL 1" THICK, 0-20 BF BF 100
REMOVE AND REPLACE EXISTING WOOD FASCIA
BOARDS, NOMINAL 1" THICK, >20 BF BF 400
PLY BURS WITH FLASHINGS, GRAVEL, ETC. (DOES
NOT INCLUDE INSULATION) SQ 250
DEMOLITION, HAULING, AND DISPOSAL OF
INSULATION UP TO 3" THICK SQ 250
REMOVE AND DISPOSE OF EXISTING ROOF SHINGLE
SYSTEM AND UNDERLAYMENT, INCLUDING
FLASHING AND DRIP EDGES SQ 100
REMOVE AND DISPOSE OF EXISTING ROLL ROOFING
AND UNDERLAYMENT, INCLUDING FLASHING AND
DRIP EDGES SQ 100
DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING
METAL ROOFING SYSTEM SQ 200
DEMOLITION, HAULING, AND DISPOSAL OF
AGGREGATE BALLAST. INCLUDE SPUDDING BACK
AGGREGATE BALLAST ON RESIDENTIAL UNITS AND
PREPARE SURFACE FOR ROLLED ROOFING SQ 200
REMOVE SINGLE PLY ROOFING (INCLUDING PVC,
EPDM, PIB, TPO AND OTHER MEMBRANE ROOFING)
DOWN TO THE DECK. INCLUDE MEMBRANE,
PENETRATION & WALL FLASHINGS AND MEMBRANE
FASTENERS. NOT TO INCLUDE INSULATION,
CRICKETS AND INSULATION FASTENERS. SQ 50
ROOF MATERIALS (ACRM) ROOF MEMBRANE. SF 500
WATER BLAST CLEAN EXISTING MASONRY SURFACE
IN ACCOURDANCE WITH PAINT MANUFACTURER'S
RECOMMENDATIONS. SF 200
CONCRETE MASONRY UNITS TO INCLUDE
GROUTING, TUCK POINTING, FORMWORK, AND
SUPPORTS. PERFORM WORK IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS.
REMOVE EXISTING STEEL ROOF DECK AND REPLACE
WITH NEW STEEL ROOF DECK SQ 50
SOFFIT FRAMING, TO INCLUDE SADDLES, CANT
STRIPS, CURBS FOR SCUTTLES AND VENTILATORS,
AND NAILERS ATTACHED AT THE TOPS OF
CONCRETE OR MASONRY CURBS, EXPANSION
JOINTS AND ROOF EDGES. FRAMING MEMBERS ARE
4" TO 8" WIDE BY 18 GAUGE OR THINNER. LF 100
RETROFIT SUB-PURLIN AND/OR FORMED SHAPED
FRAMING SYSTEM MECHANICALLY FASTENED TO
EXISTING AND/OR SUBSTRATE IN ACCORDANCE
WITH MANUFACTURES SPECIFICATIONS. MINIMUM 16
GAUGE THICKNESS LF 1000
METAL FABRICATION
SHOP PRIMED STEEL MATERIALS INCLUDING BUT
NOT LIMITED TO: PLATES, ANGLES, ANCHOR BOLTS,
STEEL PIPE SLEEVES, WEDGE TYPE INSERTS,
EXPANSION ANCHORS, FRAMING, SUPPORTS AND
FABRICATED ITEMS FOR APPLICATIONS THAT ARE
NOT SPECIFIED IN OTHER SPECIFICATION
SECTIONS. LB 50
PIPE AND TUBE RAILINGS
STAINLESS STEEL PIPE AND/OR TUBE GUARDRAIL
SYSTEM LF 12
FABRICATE AND INSTALL A SIDE OR BASE MOUNT
GALVANIZED STEEL PIPE AND/OR TUBE GUARDRAIL
SYSTEM LF 12
REMOVE AND DISPOSE OF AREAS OF
WOOD ROOF NAILERS, WHICH INCLUDES WOOD
SADDLES OR CRICKETS, CANT STRIPS, CURBS FOR
SCUTTLES AND VENTILATORS, AND WOOD NAILERS
BOLTED TO TOPS OF CONCRETE OR MASONRY
CURBS AND AT EXPANSION JOINTS BF 50
REMOVE AND REPLACE 3/8", 5/8"OR 3/4" ROOF
SHEATHING OR SOFFIT ON RESIDENTIAL UNITS SF 500
REMOVE AND REPLACE ROOF DECKING FOR
RESIDENTIAL UNITS, WHICH INCLUDES 1x OR 2x
DECKING SF 200
FURNISH AND INSTALL ROOFING LUMBER FOR
RESIDENTIAL UNITS, WHICH INCLUDES RAFTERS,
3032 1" THICK, R6.5 SQ 100
3033 2" THICK, R13 SQ 100
3034 3" THICK, R19 SQ 100
3035 4" THICK, R30 SQ 2000
PERLITE BOARD INSULATION, 3/4" THICK, R2.08
3036 <=100 SQ SQ 100
3037 > 100 SQ SQ 500
3038 BATT ROOF INSULATION, R-19 SF 1000
3039 METAL ROOF INSULATION, R30 SQ 200
3040 FIBER CANTS LF 1000
3041 WOOD CANTS LF 1000
3042 TAPERED FILL INSULATION BOARD BF 10000
3043 TAPERED 1/4" PER FOOT FOR DRAINAGE BF 10000
FIBERGLASS STRIP SHINGLE SYSTEM INCLUDING
UNDERLAYMENT SQ 300
FURNISH AND INSTALL NEW ARCHITECTURAL
DIMENSIONAL FIBERGLASS SHINGLE SYSTEM
INCLUDING UNDERLAYMENT SQ 100
REMOVE AND REPLACE EXISTING SHINGLES WITH
NEW FIBERGLASS STRIP SHINGLES TO MATCH
ADJACENT AREAS, PARTIAL REPAIRS SQ 10
ADD FOR STEEP ROOFS (7 TO 12 PITCH OR
GREATER) SQ 50
3048 FELT, GLASS FIBER, 15 POUND ORGANIC SQ 20
3049 FELT, GLASS FIBER, 30 POUND ORGANIC SQ 10
3050 4-PLY BURS USING ASPHALT SQ 250
3051 4-PLY BURS USING COAL TAR SQ 20
3052 4-PLY BURS WITH SBS MODIFIED CAP SHEET SQ 2000
3055 REMOVE AND REPLACE PITCH PAN EA 30
3056 REPAIRS BLISTERS SF 500
3057 REPAIR SPLITS LF 200
3058 REPAIR RIDGES LF 200
APPLY RESATURANT AND INSTALL NEW AGGREGATE
ON EXPOSED FELT AREAS SF 500
FIBERGLASS PREPARED ROLL ROOFING INCLUDING
3061 CUT-OUT AND PATCH ROLL ROOFING SQ 5
MILS SQ 50
FURNISH/INSTALL FULLY ADHERED PVC SYSTEM- 72
MILS SQ 50
FURNISH/INSTALL MECHANICALLY FASTENED PVC
SYSTEM- 60MILS SQ 50
FURNISH/INSTALL MECHANICALLY FASTENED PVC
SYSTEM- 72 MIL SQ 50
PVC LAMINATED METAL FLASHING UP TO 18"
STRETCH OUT LF 100
PVC LAMINATED METAL FLASHING 18.1" TO 36"
STRETCH OUT LF 100
3068 PVC VENT BOOTS EA 5
3069 PVC UNIVERSAL CORNERS EA 50
3070 PATCH AND REPAIR PVC SYSTEM SF 5
MILS SQ 10
FURNISH/INSTALL FULLY ADHERED TPO SYSTEM- 60
MILS SQ 10
FURNISH/INSTALL MECHANICALLY FASTENED TPO
SYSTEM- 45MILS SQ 20
FURNISH/INSTALL MECHANICALLY FASTENED TPO
SYSTEM - 60 MIL SQ 2000
TPO LAMINATED METAL FLASHING UP TO 18"
STRETCH OUT LF 25
TPO LAMINATED METAL FLASHING 18.1" TO 36"
STRETCH OUT LF 25
3077 TPO VENT BOOTS EA 5
3078 TPO UNIVERSAL CORNERS EA 20
3079 PATCH AND REPAIR TPO SYSTEM SF 5
ROOFS SQ 10
ENERGY STAR RATED COATING SYSTEM APPLIED TO
NEW BUR ROOFING WITH MODIFIED CAP SHEET SQ 50
3082 ELASTOMERIC COATING FOR ROOF REPAIRS SQ 10
3083 TRAFFIC-BEARING ROOF DECK SURFACING SYSTEM SQ 10
3084 GALVANIZED METAL, 4"- 5" LF 500
3085 GALVANIZED METAL, 6" - 7" LF 100
3086 ALUMINUM, 4" - 5" LF 500
3087 ALUMINUM, 6" - 7" LF 100
3088 COPPER, 4" - 5" LF 25
3089 COPPER, 6" -7" LF 25
3090 2-PIECE GALVANIZED METAL, 7" - 10" LF 50
3091 2-PIECE GALVANIZED METAL, 10" - 12" LF 50
3092 2-PIECE ALUMINUM, 7" - 10" LF 50
3093 2-PIECE ALUMINUM, 10" - 12" LF 50
3094 2-PIECE COPPER, 7" - 10" LF 50
3095 2-PIECE COPPER, 10" - 12" LF 50
3096 GALVANIZED METAL DRIP EDGE LF 200
3097 GALVANIZED METAL COUNTERFLASHING SF 100
3098 GALVANIZED METAL VALLEY FLASHING SF 100
3099 GALVANIZED METAL STEP FLASHING SF 100
3100 GALVANIZED METAL BASE FLASHING SF 100
3101 GALVANIZED METAL FLASHING- FLAT SHEET SF 100
3102 GALVANIZED METAL CAP FLASHING SF 100
3103 ALUMINUM DRIP EDGE LF 200
3104 ALUMINUM COUNTERFLASHING SF 100
3105 ALUMINUM VALLEY FLASHING SF 100
3106 ALUMINUM STEP FLASHING SF 100
3107 ALUMINUM BASE FLASHING SF 100
3108 ALUMINUM FLASHING - FLAT SHEET SF 100
3109 ALUMINUM CAP FLASHING SF 100
3110 METAL RIDGE VENT LF 100
3111 ELASTOMERIC TYPE (NEOPRENE BELLOWS) LF 100
3112 ALUMINUM CAPPED CURB LF 100
3113 GALVANIZED CAPPED CURB LF 100
3114 REMOVE AND REPLACE VENTILATOR, ROOFTOP EA 1
3115 REMOVE AND REPLACE VENTILATOR, RIDGE LF 40
3116 REMOVE AND REPLACE VENTILATOR, GABLE EA 2
REMOVE AND REPLACE CURB ASSEMBLY, METAL
WITH CRICKET, FACTORY FABRICATED AND
3118 REMOVE AND REPLACE ROOF SCUTTLE EA 1
3119 FURNISH AND INSTALL STEEL WALL PANELS SF 100
3120 REMOVE EXISTING GUTTER AND DOWNSPOUTS LF 100
3121 24 GA. GALVANIZED/PRIMED, 4" X 5" LF 500
3122 24 GA. GALVANIZED/PRIMED, 5" X 7" LF 500
3123 ALUMINUM, 4" X 5" LF 100
3124 ALUMINUM, 5" X 7" LF 100
3125 16 OZ. COPPER, 4" X 5" LF 50
3126 16 OZ. COPPER, 5" X 7" LF 50
3127 24 GA. GALVANIZED/PRIMED, 3" X 4" LF 500
3128 ALUMINUM, 3" X 4" LF 100
3129 16 OZ. COPPER, 3" X 4" LF 100
SLOPE <= 100 SQ SQ 150
STRUCTURAL<=100SQ SQ 150
NEW STANDING SEAM METAL ROOF SYSTEM,
STRUCTURAL, >100SQ SQ 4640
NEW HIGH PERFORMANCE STANDING SEAM METAL
ROOF SYSTEM, STRUCTURAL, WITH INSPECTIONS
AND WARRANTY PER SPEC NO. 07 41 20 SQ 150
NEW STANDING SEAM METAL ROOF SYSTEM,
ARCHITECTURAL SQ 150
3137 FASCIA PANEL SYSTEM SF 1000
3138 NON-PERFORATED SOFFIT PANEL SF 500
3139 PERFORATED SOFFIT PANEL SF 500
3140 REMOVE EXISTING CAULKING, CLEAN JOINT LF 150
3141 SILICONE CAULKING/SEALANT LF 150
CAULKING, MISCELLANEOUS APPLICATION
3143 PAINT, BASE SCHEME, EXT. LATEX, 1 COAT LF 1000
LEAD FLASHING, CLAMPING RING, AND CAST IRON
DOME STRAINER EA 5
REMOVE EXISTING LIGHTNING PROTECTION SYSTEM
AND REINSTALL EXISTING LIGHTNING PROTECTION
SYSTEM WITH NEW FASTENERS
3147 REMOVE AND REINSTALL EXISTING CONDUCTOR LF 250
REMOVE AND INSTALL NEW FASTENERS, INCLUDING
LOOPS AND CLIPS EA 25
AND INSTALL NEW LIGHTNING PROTECTION SYSTEM
AIR TERMINALS, INCLUDES COPPER BASE FOR NON-
METAL ROOFS EA 20
3151 CONDUCTORS LF 300
3152 FASTENERS, INCLUDES LOOPS AND CLIPS EA 100
3153 CONNECTORS EA 20
3154 COUNTERPOISE CONDUCTOR LF 1000
3155 GROUNDING RODS, 3/4" DIAMETER x 60'…