Dated 22 Aug 16

TO 11W1-12-4-32

7.1 Ultrasonic Requirements.

BRULIN FORMULA 815GD 14

Do not install plastic or any other nonmetallic parts in the ultrasonic parts washer. Nonmetal parts may become damaged during cleaning.

a. Ultrasonic washer is purchased commercially and must meet the following requirements. Cleaning tank is de- signed to hold cleaning solution and provide ultrasonic cleaning and agitation for cleaning of components, a separate tank is for clean water rinse. The dynamic processing machine must have variable sweep frequency capability and provide a water rinse with optional drying module following each wash/rinse cycle. Ultrasonic watt density shall not exceed 40 watts/gallon.

b. The temperature of the filtered washing and rinsing solution shall not exceed 160 °F and the self heated, high volume air drying module using air knives shall not exceed 200 °F. Adjustable heat and time settings for both tanks are required.

c. Solution of Formula 815GD, product number 301007 will be mixed in an approximate 5 oz. solution to 1 gallon of water. Set wash tank to 160 °F and rinse tank to 140 °F. If difficulties are observed then the cleaning times could easily be adjusted. The times and settings should be repeatable and adjustable.

7.1.1 Cleaning Cycle.

a. Wash processing time shall not exceed 10 minutes per part per cleaning operation, limited to 30 minutes

(3 cycles) for excessively soiled gun parts per cleaning operation. Parts shall not be allowed to contact the sides or bottom of the processing vessels. After cleaning, parts should be lubricated in accordance with technical order directives after processing.

b. The cleaning cycle is 10 minutes total time with the following settings:

(1) 135 seconds ultrasonic cleaning

(2) 60 seconds agitation/spray

(3) 135 seconds ultrasonic cleaning

(4) 60 seconds agitation/spray

(5) 135 seconds ultrasonic cleaning

(6) 60 seconds agitation/spray

7.1.2 Rinse Cycle. Rinse cycle should be 5 minutes in clean tap water.

Minimum tank dipping space to accommodate dimensions for Parts being cleaned: 65”Length x20”Wide x17”Deep

Gun Barrels : H - 60 Inches W – 2.5 Inches Gun Housing : H – 14.5 Inches W – 12 Inches

All other components will fit in those dimensions.