1. What size MWIR lens is required?
Answer - 50mm and 13mm, respectively, however, lens specifications meeting these requirements are left to the bidder, and will be based in part on the offered camera’s CCD size.
2. What is the detection range of the 12’ x 120” target?
Answer - threshold 0-350 degrees Celsius, objective 0-600 degrees Celsius
3. Do you need raw data through GigE or is Camera Link sufficient?
Answer - GigE interface between camera and controller
5. Housing environmental? IP 67 etc.
Answer - A minimum Ingress Protection (IP) rating of 67 on the camera housing
6. Are lenses required for these Infrared Cameras? How many lenses?
AFRL calculations indicate that TWO SETS OF LENSES will be required to satisfy these conditions: 50mm and 13mm, respectively, however, lens specifications meeting these requirements are left to the bidder, and will be based in part on the offered camera’s CCD size.