ORANGEBURG NATIONAL FISH HATCHERY

SCOPE OF WORK

SKYLIGHTS

The scope of work for this project shall include the mobilization, demobilization and supply of all labor, materials, and equipment necessary to remove and dispose of seventeen (17) existing sky lights and to replace the seventeen (17) skylights with seventeen (17) new, compatible with the current roof system, insulated roof light panels to match existing NCI (Metallic) brand name or equal to panel by Metallic

Building System.

Light Transmitting Panels | MBCI Page 1 of 3

Sign Up For Our Newsletter

I Blog (http://blog.mbci.com/) Contact Us (/locations/) About Us (/about-us/)

I I

Architects ~ Contractors

Light Transmitting Panels

STANDING SEAM ROOF ACCESSORIES ~

Home(/) / Products (/products/) / Components (/products/components/) / Accessories

(/products/components/accessories/) / Standing Seam Roof (/products/components/accessories/standing-seam-roof-accessories/) / Light Transmitting Panels

Light Transmitting Panels

Light Transmitting Panel - UL90 - Field Installed LTP Kit

• The Field Installed Kit consists of:

(1) - HW-1470 LTP Panel (Uninsulated) or (1) - HW-1471 LTP Panel

(Insulated)

(2) - HW-1210 Double-Lok Repair Caps (Mill Finish Aluminum), (1) - HW-

1474 Fastener Bag (Unpainted)

• (2) - HW-7760 Back-Up Plates, (2) tubes of HW-540 Urethane Sealant

(White) and (2) rolls of Tri-Bead Tape Sealer It is the users responsibility to ensure that the installation and use of all light transmitting panels comply with State, Federal and OSHA regulations and laws, including, but not limited to, guarding all light transmitting panels with screens, fixed standard railings, or other acceptable safety controls that prevent fall-through.

Part*

HW-1472

1 HW-1473

Type

Uninsulated

Insulated

Width Length

24" 10'-3"

24" 10'-3"

LTP Color

White

White

Weight Each

32.95#

39.70#

Light Transmitting Panel - UL90 - Rivetej Rail LTP

It is the usersnssgonsibility to ensy«rfliat the installation and use of all light transmitting paflelscpwiply with State, Federal and OSHA regulations and lajisfTncluaTrigjDut not limited to, guarding all light transmittjpg-panels with screens, fnted^tandard railings, or other acceptable safety controls that prevent fait^thcpugh.