1. REQUSITION NUMBER
5000038103
2. CONTRACT NO. 3.AWARD/EFFECTIVE DATE 4. ORDER NUMBER 5. SOLICITATION NUMBER
EP2864-16
6. SOLICITATION ISSUE DATE
03/21/2016
7. FOR SOLICITATION
INFORMATION CALL:
a. NAME
Sheila D. Gonzales
b. TELEPHONE NUMBER (No collect calls)
512-321-3903
8. OFFER DUE DT/LOCAL TIME
2:00PM
9. ISSUED BY CODE
UNICOR, FPI Central Office UNICOR FPI Central Office Washington, DC 20534
10. THIS AQUISITION IS
UNRESTRICTED
X SET ASIDE100 % FOR
X SMALL BUSINESS
SMALL DISADV.BUSINESS
8(A)
SIC: 3714
SIZE STANDARD: 500 Emp.
11. DELIVERY FOR FOB
DESTINATION UNLESS
BLOCK IS MARKED
SEE SCHEDULE
12. DISCOUNT TERMS
13a. THIS CONTRACT IS A RATED ORDER
UNDER DPAS (15 CFR 700)
13b. RATING
14. METHOD OF SOLICITATION
RFQ IFB X RFP
16. ADMINISTERED BY CODE
UNICOR, FPI Central Office UNICOR FPI Central Office Washington, DC 20534
17a. CONTRACTOR/OFFEROR CODE 999999999 FACILITY CODE
TELEPHONE NO. TIN:
RFQ: 6200008501
17b. CHECK IF REMITANCE IS DIFFERENT AND PUT SUCH ADDRESS IN OFFER
18a. PAYMENT WILL BE MADE BY CODE
18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a UNLESS BLOCK BELOW
IS CHECKED SEE ADDENDUM
19.
ITEM NO.
20.
SCHEDULE OF SUPPLIES/SERVICES
See Section B
21.
QUANTITY
22.
UNIT
23.
UNIT PRICE
24.
AMOUNT
25. ACCOUNTING AND APPROPRIATION DATA 26. TOTAL AWARD AMOUNT (For Govt. Use Only)
X 27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1, 52.212-4. FAR 52.212-3 AND 52.212-5 ARE ATTACHED. ADDENDA X ARE ARE NOT ATTACHED
27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA ARE ARE NOT ATTACHED
28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN 1 COPIES
TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND DELIVER ALL ITEMS SET
X FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY ADDITIONAL SHEETS SUBJECT TO
THE TERMS AND CONDITIONS SPECIFIED HEREIN.
29. AWARD OF CONTRACT: REFERENCE __________________________________
OFFER DATED __________________. YOUR OFFER ON SOLICITATION (BLOCK 5),
INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE SET FORTH HERIN,
ACCEPTED AS TO ITEMS:
30a. SIGNATURE OF OFFEROR/CONTRACTOR
30b. NAME AND TITLE OF SIGNER (TYPE OR PRINT) 30c. DATE SIGNED
31a. UNITED STATES OF AMERICA (SIGNATURE OF CONTRACTING OFFICER)
31b. NAME OF CONTRACTING OFFICER (TYPE OR PRINT)
Sheila D. Gonzales 512-321-3903
31c. DATE SIGNED
03/24/2016
32a. QUANTITY IN COLUMN 21 HAS BEEN
RECEIVED INSPECTED ACCEPTED, AND CONFORMS TO THE
CONTRACT EXCEPT AS NOTED
32b. SIGNATURE OF AUTHORIZED GOVT. REPRESENTATIVE 32c. DATE
33. SHIP NUMBER
PARTIAL FINAL
34. VOUCHER NUMBER 35. AMOUNT VERIFIED
CORRECT FOR
36. PAYMENT
COMPLETE PARTIAL FINAL
37. CHECK NUMBER
38. S/R ACCOUNT NUMBER
42a. RECEIVED BY (Print)
42b. RECEIVED AT (Location)
42c. DATE REC'D (YY/MM/DD)
39. S/R VOUCHER NUMBER 40. PAID BY
41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT
41b. SIGNATURE AND TITLE OF CERTIFYING OFFICER 41c. DATE
42d. TOTAL CONTAINERS
15. DELIVER TO CODE
AUTHORIZED FOR LOCAL REPRODUCTION STANDARD FORM 1449 (10-95)
Prescribed by GSA - FAR (48 CFR) 53.212
PAGE 1 OF
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS
OFFEROR TO COMPLETE BLOCKS 12,17,23,24 & 30
Terms of delivery: DST
TERMS OF DELIVERY ARE F.O.B. DESTINATION TO:
UNICOR Federal Prison Industries
1341 Hwy. 95 N.
Bastrop, TX 78602
UNICOR Federal Prison Industries
8500 Doniphan Dr.
Anthony, TX 79821
UNICOR Federal Prison Industries
4200 Bureau Rd. North
Terre Haute, IN 47802
UNICOR Federal Prison Industries
13777 Air Expressway Blvd.
Victorville, CA 92394
UNICOR Federal Prison Industries
201 FCI Lane
Glenville, WV 26351
Solicitation is issued as a five (5) year firm fixed price requirements type contract with Economic Price Adjustment for PCU441310441310 Automotive Parts and Accessories.
Offerors which do not agree with the Producer Price Index listed above are required to submit the price index that they believe is correct to the contracting officer at least five (5) calendar days prior to the due date for offers.
The index submitted will be evaluated, and changed by amendment to the solicitation if necessary.
PPI #____________________________________________
SOLICITATION IS 100% SET-ASIDE FOR SMALL BUSINESS.
QUESTIONS PERTAINING TO THIS SOLICITATION WILL ONLY BE ADDRESSED IN WRITING VIA EMAIL TO: Sheila.gonzales2@usdoj.gov.
QUESTIONS MUST BE RECEIVED BY APRIL 1, 2016. ANY QUESTIONS RECEIVED AFTER THIS DATE WILL NOT BE ADDRESSED. NO PHONE
CALLS PLEASE.
For a list, description and total estimated quantities of all items, refer to Section B.
Offerors ARE REQUIRED to submit one (1) each of the following FPI stock numbers: SWH0559PI - Siren Controller for
2016 Ford F150; LMPFD46STD0001 - Standard Lightbar for 2016 Ford F150; LMPFD46STD0002 - Lightbar with Traffic Advisor for 2016 Ford F150; LMP2386 - Red Intersection Light with Bezel; LMP2387 - Blue Intersection Light with Bezel; LMP1098
- Universal Full Visor Light; LMP2453 - Full Visor Light for 2016 Ford F150; and SPK0021PI - Speaker for 2016 Ford
F150, for technical evaluation to verify form, fit and function of the material. Contractors are required to submit the material by the closing date, Monday, April 25, 2016 at 2:00 p.m. CST. The shipping address for the material is:
UNICOR, 1341 Hwy 95 N., Bastrop, TX 78602, ATTN: Sheila D. Gonzales, Contract Specialist. Material that is not received by the closing date and time will not be evaluated and the proposal will not be considered further for award.
Please note solicitation EP2864-16 and your company's name/address on the packing slip for the material that is sent.
Contractors are responsible for the total cost of the sample, including shipping of the material for evaluation.
Contractors must provide a pre-paid return label so UNICOR can return the product after evaluation.
DJU6200008501 PAGE 2 OF 2641
Request For Quote
UNICOR's desired delivery is 30 days or sooner after issuance of each delivery order. Vendors are required to provide their best manufacturing/delivery time for evaluation, and delivery schedule will be established at time of award.
Delivery orders will be issued in accordance with 52.216-19.
Vendors shall submit signed and dated offers either by facsimile or overnight delivery (FedEx, UPS, etc.). Facsimile number is 352-330-8293. Any of the overnight delivery carriers will be accepted with delivery to: UNICOR Federal
Prison Industries, 1341 Hwy. 95 N., Bastrop, TX 78602 Attn: Sheila D. Gonzales. Offers shall be submitted on the
SF1449. OMB Clearance 1103-0018.
The date and time for receipt of proposals is Monday, April 25, 2016 at 2:00 p.m. CST. Offer must indicate
Solicitation No. EP2864-16, time specified for receipt of offer, name, address and telephone number of offeror, technical description of the items being offered in sufficient detail to evaluate compliance with the requirements in the solicitation, terms of any expressed warranty, price and any discount terms. Offer must include acknowledgment of all amendments, if any.
THE FOLLOWING INFORMATION IS REQUIRED TO BE COMPLETED BY THE OFFEROR:
VENDOR'S DUN & BRADSTREET NUMBER:_______________________________
VENDOR'S POINT OF CONTACT: _____________________________________
VENDOR'S TELEPHONE & FAX NUMBER: _______________________________
VENDOR'S EMAIL ADDRESS: ________________________________________
VENDOR'S BUSINESS SIZE (i.e. SMALL, LARGE, ETC.): ________________
By submission of an offer, the offeror acknowledges the requirement that a prospective awardee shall be registered in the SAM database (System Award Management) prior to award, during performance and through final payment of any contract resulting from this solicitation.
_______________________________________________ Signature
The Administrative Contracting officer is Sheila D. Gonzales at Sheila.gonzales2@usdoj.gov.
SECTION B
SUPPLIES OR SERVICES AND PRICES/COSTS
Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date
DJU6200008501 PAGE 3 OF 2641
SECTION B
SUPPLIES OR SERVICES AND PRICES/COSTS
Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date
00001 LMPCH100STD0001 500 EA 5000038103
LIGHTBAR,ALL,LED,STD,CH-TAHOE
THIS LIGHT BAR WILL FIT THE CHEVY TAHOE.
LENGTH: 54 INCHES, TOLERANCE: + OR - (2) TWO INCHES
INCLUDES STAINLESS STEEL GUTTER RAIL STYLE MOUNTS AND ACCOMPANYING
HARDWARE FOR ROOF TOP INSTALLATION. MUST INCLUDE INSTALLATION
INSTRUCTIONS AND
SIX (6) RIVETS
HEAD STYLE: Dome
RIVET MATERIAL: Stainless Steel
MANDREL MATERIAL: Stainless Steel
RIVET DIAMETER: 3/16 Inch
GRIP RANGE: 3/8 - 1/2 Inch
STANDARD LIGHT CONFIGURATION, LED, LIGHT BAR, W/5 WATT ½ AMP (MINIMUM)
SOLAR PANEL AND SOLAR PANEL REGULATOR W/LED INDICATOR, WITH 26 INCH
PIGTAIL TO ROOF TOP MOUNTED QUICK DISCONNECT BULKHEAD CONNECTOR, 23
POSITION ROOF TOP MOUNTED BULKHEAD CONNECTOR, AND ALL ACCOMPANYING
WIRING TO AND FROM ROOF TOP CONNECTOR AND SIREN CONTROLLER AND FROM ROOF
TOP CONNECTOR TO SOLAR PANEL REGULATOR.
1) MEETS ALL APPLICABLE SAE, FMVSS AND CALIFORNIA TITLE XIII STANDARDS
WHEN PROPERLY CONFIGURED.
2) ALL LED MODULES WILL BE CLEAR UNTIL ILLUMINATED AND WILL BE HIGH
INTENSITY LEDs.
3) FIVE YEAR WARRANTY MINIMUM.
4) LOW PROFILE MODULAR DESIGN.
5) CORROSION RESISTANT ALL ALUMINUM HOUSING WITH NO PLASTIC OR COMPOSITE
COVERS.
6) UV RESISTANT POLY CARBONATE LENS.
7) ABILITY TO INTEGRATE DIRECTIONAL INDICATORS FOR REAR FACING MODULES.
8) FULL 360° VISIBILITY.
9) MAINTENANCE FREE.
10) WILL OPERATE ON 12 VOLT NEGATIVE GROUND SYSTEM.
11) SOLID - STATE ELECTRONICS NOT EXCEEDING 12 AMPS AT FULL OPERATION.
12) ALL FORWARD AND REAR FACING MODULES WILL HAVE (6) LEDs MINIMUM PER
MODULE.
13) ALL CORNER MODULES WILL HAVE (12) LEDs MINIMUM PER MODULE.
14) TAKE DOWN MODULES WILL BE HIGH INTENSITY LEDs (CLEAR).
15) ALLEY MODULES WILL BE HIGH INTENSITY LEDs (CLEAR)
16) EACH CORNER WILL CONTAIN AT MINIMUM ONE 12 LED LIGHT HEAD MODULE.
17) FORWARD FACING OPTICAL INDICATORS WILL HAVE A MINIMUM OF FOUR, (6)
SIX LED LIGHT HEAD MODULES AND (2) TWO LED TAKE DOWN MODULES WITH A
MINIMUM OF (3) THREE HIGH INTENSITY LEDs.
18) TAKE DOWN LEDs WILL FLASH ALTERNATELY AND ACTIVATE WITH
FRONT LEDs. THIS FEATURE WILL BE OVERRIDDEN WHEN TAKE DOWNS ARE
DJU6200008501 PAGE 4 OF 2641
Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date
INDEPENDENTLY ACTIVATED.
19) REAR FACING OPTICAL INDICATORS WILL HAVE A MINIMUM OF SIX, (6) SIX
LED LIGHT HEAD MODULES.
20) DRIVER SIDE EXIT HOLE FOR HARNESS.
21) THE DRIVER SIDE OUTBOARD FORWARD FACING RED MODULE SHALL BE
PROGRAMMABLE TO INCLUDE STEADY # BURN MODE. THIS WILL BE PROGRAMMED AT
INSTALLATION IF CALIFORNIA TITLE XIII IS APPLICABLE.
22) THE FORWARD FACING MODULES FROM CENTER OUTWARD: TO THE
DRIVER SIDE WILL BE TAKE DOWN, FLASHING RED, FLASHING PROGRAMMABLE
RED. TO THE PASSENGER SIDE WILL BE TAKE DOWN, FLASHING BLUE, FLASHING
BLUE.
23) THE REAR FACING MODULES FROM CENTER OUTWARD: TO THE DRIVER SIDE
WILL BE FLASHING RED, FLASHING RED, FLASHING AMBER. TO THE PASSENGER
SIDE WILL BE FLASHING BLUE, FLASHING BLUE, FLASHING AMBER.
24) THE DRIVER SIDE CORNERS (FRONT AND REAR) WILL BE FLASHING RED.
25) THE PASSENGER SIDE CORNERS (FRONT AND REAR) WILL BE FLASHING BLUE.
26) LIGHT BAR MODULE PLACEMENT DESCRIPTION:
FRONT OF LIGHT BAR FROM DRIVER SIDE TO PASSENGER SIDE:
PROGRAMMABLE DRIVER RED, DRIVER RED, DRIVER CLEAR TAKE DOWN, PASSENGER
CLEAR TAKE DOWN, PASSENGER BLUE, PASSENGER BLUE
BACK OF LIGHT BAR FROM DRIVERS SIDE TO PASSENGER SIDE:
DRIVER AMBER, DRIVER RED, DRIVER RED
PASSENGER BLUE, PASSENGER BLUE, PASSENGER AMBER.
DRIVERS SIDE CORNER OF LIGHT BAR:
CORNER RED, LEFT ALLEY, CORNER RED.
PASSENGER SIDE CORNER OF LIGHT BAR:
CORNER BLUE, RIGHT ALLEY, CORNER BLUE.
27) LIGHT HEAD ACTIVATION SPECIFICATIONS AND WIRE COLORS ARE AS FOLLOWS:
WIRE #1 = GREEN/BLACK 18 AWG., WILL ACTIVATE ALL REAR FACING LIGHT
MODULES INCLUDING THE REAR CORNERS, PIN POSITION (V) OF MALE 23 PIN
QUICK DISCONNECT CONNECTOR.
WIRE #2 = RED/WHITE 18 AWG., WILL ACTIVATE ALL FORWARD FACING LIGHT
MODULES INCLUDING THE FRONT CORNERS, PIN POSITION (J) OF MALE 23 PIN
QUICK DISCONNECT CONNECTOR.
WIRE #3 = ORANGE/BLACK 18 AWG., WILL ACTIVATE THE LEFT ALLEY LIGHT
MODULE, PIN POSITION (S) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.
WIRE #4 = ORANGE 18 AWG., WILL ACTIVATE THE RIGHT ALLEY LIGHT MODULE,
PIN POSITION (U) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.
WIRE #5 = BLUE 18 AWG., WILL ACTIVATE BOTH TAKE DOWN LIGHT MODULES, PIN
POSITION (M) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.
WIRE #6 = RED/BLACK 18 AWG., THIS WILL ACTIVATE THE PROGRAMMABLE DRIVER
SIDE OUTBOARD LIGHT MODULE FOR STEADY BURN MODE ON CALIFORNIA TITLE XIII
COMPLIANT VEHICLES. THIS MODULE WILL BE PROGRAMMED AT INSTALLATION. IT
WILL BE REQUIRED TO BE FIELD PROGRAMMABLE, PIN POSITION (K) OF MALE 23
DJU6200008501 PAGE 5 OF 2641
Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date
PIN QUICK DISCONNECT CONNECTOR.
GROUND #1 = BLACK 18 AWG., PIN POSITION (D) OF MALE 23 PIN QUICK
DISCONNECT CONNECTOR.
GROUND #2 = BLACK 18 AWG., PIN POSITION (E) OF MALE 23 PIN QUICK
DISCONNECT CONNECTOR.
GROUND #3 = BLACK 18 AWG., PIN POSITION (F) OF MALE 23 PIN QUICK
DISCONNECT CONNECTOR.
GROUND #4 = BLACK 18 AWG., PIN POSITION (G) OF MALE 23 PIN QUICK
DISCONNECT CONNECTOR.
28) A 5-6 WATT, ½ AMP (MINIMUM) SOLAR PANEL WILL BE MOUNTED TO THE UPPER
SECTION OF THE LIGHT BAR, THE SOLAR PANEL MUST WORK WITH ALL BATTERIES,
HAVE HIGH PULSING DE-SULPHATION AT 22-28 KHZ, MAX DC VOLTAGE CHARGE OF
16.5 VOLTS AT DIRECT SUNLIGHT. MUST BE DESIGNED FOR RENEWAL AND MINIMUM
CHARGING OF BATTERIES, SOLAR PANEL CAN HAVE BETWEEN 80 AND 150 SQUARE
INCHES OF LIGHT COLLECTION AREA. THE SOLAR PANEL MUST INCLUDE THE SOLAR
PANEL REGULATOR. THE REGULATOR MUST HAVE A RED BLINKING LED THAT
DESIGNATES PROPER FUNCTION OF PANEL. ALL WIRING AND CONNECTORS MUST BE
INCLUDED AND BE INCORPORATED INTO THE LIGHT BAR WIRING HARNESS.
THE SOLAR PANEL WIRING FROM THE LIGHT BAR TO THE MALE 23 PIN QUICK
DISCONNECT PLUG WILL BE AS FOLLOWS:
RED = PIN POSITION (H) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.
BLACK = PIN POSITION (Z) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.
YELLOW = PIN POSITION (P) OF MALE 23 PIN QUICK DISCONNECT
CONNECTOR.
29) THE LEADS FROM THE SOLAR PANEL REGULATOR THAT CONNECT TO THE
VEHICLES BATTERY WILL BE (32) THIRTY TWO INCHES IN LENGTH WITH A PACKARD
DELPHI METRI PACK 150 SERIES SEALED TWO CAVITY FEMALE CONNECTOR THAT
HOUSES FEMALE TERMINAL SOCKETS (12) TWELVE INCHES FROM THE REGULATOR,
THE MALE 2 PIN CONNECTOR THAT HOUSES MALE TERMINAL PINS WILL HAVE THE
REMAINING (20) TWENTY INCHES OF RED/BLACK DUPLEX WIRE FOR CONNECTION TO
THE BATTERY TERMINALS.
TWO CAVITY CONNECTOR PIN OUTS AS FOLLOWS:
RED = PIN POSITION (A)
BLACK = PIN POSITION (B)
30) THE LEADS FROM THE SOLAR PANEL REGULATOR TO THE MALE THREE CAVITY
CONNECTOR THAT CONNECTS TO THE LIGHT BAR HARNESS WILL BE (18) EIGHTEEN
INCHES, THE CONNECTOR WILL BE A PACKARD DELPHI METRI PACK 150 SERIES
SEALED CONNECTOR THAT HOUSES THE MALE TERMINAL PINS.
THE THREE (3) CAVITY CONNECTOR PIN OUTS AS FOLLOWS:
RED = PIN POSITION (A)
BLACK = PIN POSITION (B)
YELLOW = PIN POSITION (C)
31) THE CABLE FROM THE LIGHT BAR EXIT HOLE TO THE ROOF TOP MOUNTED
FEMALE QUICK DISCONNECT BULKHEAD CONNECTOR WILL BE 26 INCHES LONG, IT
WILL TERMINATE INTO A MALE 23 PIN CONNECTOR THAT HOUSES MALE TERMINAL
PINS, IT WILL BE A SEALED CABLE INCORPORATING ALL WIRING FOR THE LIGHT
DJU6200008501 PAGE 6 OF 2641
Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date
MODULES AND THE SOLAR PANEL. THE CONNECTOR WILL BE A STRAIGHT PLUG THAT
WILL FIT INTO THE ROOF TOP MOUNTED BULKHEAD CONNECTOR WITH A TWIST TO
LOCK IN PLACE FEATURE. IT WILL ACCEPT 16-18 AWG AND THE 23 PINS WILL BE
DESIGNATED BY LETTERS OF THE ALPHABET FOR MATING TO THE PROPER SOCKETS
OF THE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR.
32) MUST INCLUDE ALL NECESSARY MOUNTING HARDWARE AND SEALS TO MOUNT
LIGHT BAR HARNESS THROUGH ROOF VIA THE ROOF TOP BULKHEAD CONNECTOR; THE
FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR THAT HOUSES THE FEMALE
SOCKET TERMINALS; THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD
CONNECTOR TO THE SIREN CONTROLLER ADAPTOR PLUG; THE WIRING FROM THE
FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR TO THE GROUND LUG RING
CONNECTOR AND THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD
CONNECTOR TO THE SOLAR PANEL REGULATOR ADAPTOR PLUG.
33) THE 23 SOCKET ROOF TOP MOUNTED BULKHEAD CONNECTOR IS A 90°, AERO-
DYNAMICALLY SHAPED PLUG. HEIGHT WILL BE NO MORE THAN 40 MM. AND WIDTH
WILL BE NO MORE THAN 75 MM. AND LENGTH WILL BE NO LONGER THAN 90 MM. IT
WILL HAVE A RUBBER GASKET FOR MOUNTING SEAL AND WILL HAVE A MINIMUM OF
FOUR SCREW MOUNTING POINTS FOR THROUGH ROOF MOUNTING. THE WIRE ACCESS
HOLE WILL BE 1 ¼ INCH. IT WILL ACCEPT FEMALE SOCKET TERMINALS AND THE
SOCKETS ARE CAPABLE OF ACCEPTING 16-18 AWG. THE QUICK DISCONNECT
RECEIVER OF THE CONNECTOR WILL RECEIVE THE MALE 23 PIN CONNECTOR. IT HAS
TWIST TO LOCK IN PLACE TABS FOR SECURE MATING TO THE MALE PLUG.
34) THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR TO
THE SIREN CONTROLLER ADAPTOR PLUG WILL BE (15) FIFTEEN FEET LONG. THE
SIREN CONTROLLER ADAPTOR PLUG WILL BE A PACKARD DELPHI METRI PACK 150
SERIES SEALED (6) SIX CAVITY CONNECTOR; IT WILL BE THE MALE END THAT
HOUSES THE MALE TERMINAL PINS.
THE SIX (6) CAVITY CONNECTOR PIN OUTS ARE AS FOLLOWS:
GREEN/BLACK = WIRE 1 =POSITION (A)
RED/WHITE = WIRE 2 = POSITION (B)
ORANGE/BLACK = WIRE 3 = POSITION (C)
ORANGE = WIRE 4 = POSITION (D)
BLUE = WIRE 5 =POSITION (E)
RED/BLACK = WIRE 6 =POSITION (F)
THE WIRE CONNECTIONS TO THE 23 SOCKET ROOF TOP MOUNTED BULKHEAD
CONNECTOR ARE AS FOLLOWS:
GREEN WITH BLACK = WIRE 1 =POSITION (V)
RED WITH WHITE = WIRE 2 = POSITION (J)
ORANGE WITH BLACK= WIRE 3 = POSITION (S)
ORANGE = WIRE 4 = POSITION (U)
BLUE = WIRE 5 =POSITION (M)
RED WITH BLACK = WIRE 6 =POSITION (K)
35) THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR TO
THE SOLAR PANEL ADAPTOR PLUG WILL BE (16) SIXTEEN FEET LONG. THE SOLAR
PANEL ADAPTOR PLUG WILL BE A PACKARD DELPHI METRI PACK 150 SERIES SEALED
(3) THREE CAVITY CONNECTOR. IT WILL BE THE FEMALE END THAT HOUSES THE
FEMALE TERMINAL SOCKETS.
DJU6200008501 PAGE 7 OF 2641
Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date
THE THREE (3) CAVITY FEMALE CONNECTOR PIN OUTS ARE AS FOLLOWS:
RED = PIN POSITION (A)
BLACK = PIN POSITION (B)
YELLOW = PIN POSITION (C)
THE WIRE CONNECTIONS TO THE 23 SOCKET ROOF TOP MOUNTED BULKHEAD
CONNECTOR ARE AS FOLLOWS:
RED = PIN POSITION (H)
BLACK = PIN POSITION (Z)
YELLOW = PIN POSITION (P)
36) THE GROUND WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD
CONNECTOR TO THE GROUND LUG RING TERMINAL WILL BE (17) SEVENTEEN FEET
LONG. THE (4) FOUR GROUND WIRES WILL TERMINATE INTO (1) ONE NON SHIELDED
RING CONNECTOR WITH A ¼ INCH EYELET. THE PIN POSITIONS OF THE GROUND
WIRES IN THE FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR ARE AS
FOLLOWS:
GROUND #1 = BLACK 18 AWG., PIN POSITION (D) OF FEMALE 23 SOCKET ROOF TOP
MOUNTED BULKHEAD CONNECTOR.
GROUND #2 = BLACK 18 AWG., PIN POSITION (E) OF FEMALE 23 SOCKET ROOF TOP
MOUNTED BULKHEAD CONNECTOR.
GROUND #3 = BLACK 18 AWG., PIN POSITION (F) OF FEMALE 23 SOCKET ROOF TOP
MOUNTED BULKHEAD CONNECTOR.
GROUND #4 = BLACK 18 AWG., PIN POSITION (G) OF FEMALE 23 SOCKET ROOF TOP
MOUNTED BULKHEAD CONNECTOR.
DJU6200008501 PAGE 8 OF 2641
Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date
00002 LMPCH108STD0001 100 EA 5000038103
LIGHTBAR,ALL,LED,STD,CH-SUBURBAN
THIS LIGHT BAR WILL FIT THE CHEVY SUBURBAN.
LENGTH: 54 INCHES, TOLERANCE: + OR - (2) TWO INCHES
INCLUDES STAINLESS STEEL GUTTER RAIL STYLE MOUNTS AND ACCOMPANYING
HARDWARE FOR ROOF TOP INSTALLATION. MUST INCLUDE INSTALLATION
INSTRUCTIONS AND
SIX (6) RIVETS
HEAD STYLE: Dome
RIVET MATERIAL: Stainless Steel
MANDREL MATERIAL: Stainless Steel
RIVET DIAMETER: 3/16 Inch
GRIP RANGE: 3/8 - 1/2 Inch
STANDARD LIGHT CONFIGURATION, LED, LIGHT BAR, W/5 WATT ½ AMP (MINIMUM)
SOLAR PANEL AND SOLAR PANEL REGULATOR W/LED INDICATOR, WITH 26 INCH
PIGTAIL TO ROOF TOP MOUNTED QUICK DISCONNECT BULKHEAD CONNECTOR, 23
POSITION ROOF TOP MOUNTED BULKHEAD CONNECTOR, AND ALL ACCOMPANYING
WIRING TO AND FROM ROOF TOP CONNECTOR AND SIREN CONTROLLER AND FROM ROOF
TOP CONNECTOR TO SOLAR PANEL REGULATOR.
1) MEETS ALL APPLICABLE SAE, FMVSS AND CALIFORNIA TITLE XIII STANDARDS
WHEN PROPERLY CONFIGURED.
2) ALL LED MODULES WILL BE CLEAR UNTIL ILLUMINATED AND WILL BE HIGH
INTENSITY LEDs.
3) FIVE YEAR WARRANTY MINIMUM.
4) LOW PROFILE MODULAR DESIGN.
5) CORROSION RESISTANT ALL ALUMINUM HOUSING WITH NO PLASTIC OR COMPOSITE
COVERS.
6) UV RESISTANT POLY CARBONATE LENS.
7) ABILITY TO INTEGRATE DIRECTIONAL INDICATORS FOR REAR FACING MODULES.
8) FULL 360° VISIBILITY.
9) MAINTENANCE FREE.
10) WILL OPERATE ON 12 VOLT NEGATIVE GROUND SYSTEM.
11) SOLID - STATE ELECTRONICS NOT EXCEEDING 12 AMPS AT FULL OPERATION.
12) ALL FORWARD AND REAR FACING MODULES WILL HAVE (6) LEDs MINIMUM PER
MODULE.
13) ALL CORNER MODULES WILL HAVE (12) LEDs MINIMUM PER MODULE.
14) TAKE DOWN MODULES WILL BE HIGH INTENSITY LEDs (CLEAR).
15) ALLEY MODULES WILL BE HIGH INTENSITY LEDs (CLEAR)
16) EACH CORNER WILL CONTAIN AT MINIMUM ONE 12 LED LIGHT HEAD MODULE.
17) FORWARD FACING OPTICAL INDICATORS WILL HAVE A MINIMUM OF FOUR, (6)
SIX LED LIGHT HEAD MODULES AND (2) TWO LED TAKE DOWN MODULES WITH A
MINIMUM OF (3) THREE HIGH INTENSITY LEDs.
18) TAKE DOWN LEDs WILL FLASH ALTERNATELY AND ACTIVATE WITH
FRONT LEDs. THIS FEATURE WILL BE OVERRIDDEN WHEN TAKE DOWNS ARE
DJU6200008501 PAGE 9 OF 2641
Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date
INDEPENDENTLY ACTIVATED.
19) REAR FACING OPTICAL INDICATORS WILL HAVE A MINIMUM OF SIX, (6) SIX
LED LIGHT HEAD MODULES.
20) DRIVER SIDE EXIT HOLE FOR HARNESS.
21) THE DRIVER SIDE OUTBOARD FORWARD FACING RED MODULE SHALL BE
PROGRAMMABLE TO INCLUDE STEADY # BURN MODE. THIS WILL BE PROGRAMMED AT
INSTALLATION IF CALIFORNIA TITLE XIII IS APPLICABLE.
22) THE FORWARD FACING MODULES FROM CENTER OUTWARD: TO THE
DRIVER SIDE WILL BE TAKE DOWN, FLASHING RED, FLASHING PROGRAMMABLE
RED. TO THE PASSENGER SIDE WILL BE TAKE DOWN, FLASHING BLUE, FLASHING
BLUE.
23) THE REAR FACING MODULES FROM CENTER OUTWARD: TO THE DRIVER SIDE
WILL BE FLASHING RED, FLASHING RED, FLASHING AMBER. TO THE PASSENGER
SIDE WILL BE FLASHING BLUE, FLASHING BLUE, FLASHING AMBER.
24) THE DRIVER SIDE CORNERS (FRONT AND REAR) WILL BE FLASHING RED.
25) THE PASSENGER SIDE CORNERS (FRONT AND REAR) WILL BE FLASHING BLUE.
26) LIGHT BAR MODULE PLACEMENT DESCRIPTION:
FRONT OF LIGHT BAR FROM DRIVER SIDE TO PASSENGER SIDE:
PROGRAMMABLE DRIVER RED, DRIVER RED, DRIVER CLEAR TAKE DOWN, PASSENGER
CLEAR TAKE DOWN, PASSENGER BLUE, PASSENGER BLUE
BACK OF LIGHT BAR FROM DRIVERS SIDE TO PASSENGER SIDE:
DRIVER AMBER, DRIVER RED, DRIVER RED
PASSENGER BLUE, PASSENGER BLUE, PASSENGER AMBER.
DRIVERS SIDE CORNER OF LIGHT BAR:
CORNER RED, LEFT ALLEY, CORNER RED.
PASSENGER SIDE CORNER OF LIGHT BAR:
CORNER BLUE, RIGHT ALLEY, CORNER BLUE.
27) LIGHT HEAD ACTIVATION SPECIFICATIONS AND WIRE COLORS ARE AS FOLLOWS:
WIRE #1 = GREEN/BLACK 18 AWG., WILL ACTIVATE ALL REAR FACING LIGHT
MODULES INCLUDING THE REAR CORNERS, PIN POSITION (V) OF MALE 23 PIN
QUICK DISCONNECT CONNECTOR.
WIRE #2 = RED/WHITE 18 AWG., WILL ACTIVATE ALL FORWARD FACING LIGHT
MODULES INCLUDING THE FRONT CORNERS, PIN POSITION (J) OF MALE 23 PIN
QUICK DISCONNECT CONNECTOR.
WIRE #3 = ORANGE/BLACK 18 AWG., WILL ACTIVATE THE LEFT ALLEY LIGHT
MODULE, PIN POSITION (S) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.
WIRE #4 = ORANGE 18 AWG., WILL ACTIVATE THE RIGHT ALLEY LIGHT MODULE,
PIN POSITION (U) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.
WIRE #5 = BLUE 18 AWG., WILL ACTIVATE BOTH TAKE DOWN LIGHT MODULES, PIN
POSITION (M) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.
WIRE #6 = RED/BLACK 18 AWG., THIS WILL ACTIVATE THE PROGRAMMABLE DRIVER
SIDE OUTBOARD LIGHT MODULE FOR STEADY BURN MODE ON CALIFORNIA TITLE XIII
DJU6200008501 PAGE 10 OF 2641
Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date
COMPLIANT VEHICLES. THIS MODULE WILL BE PROGRAMMED AT INSTALLATION. IT
WILL BE REQUIRED TO BE FIELD PROGRAMMABLE, PIN POSITION (K) OF MALE 23
PIN QUICK DISCONNECT CONNECTOR.
GROUND #1 = BLACK 18 AWG., PIN POSITION (D) OF MALE 23 PIN QUICK
DISCONNECT CONNECTOR.
GROUND #2 = BLACK 18 AWG., PIN POSITION (E) OF MALE 23 PIN QUICK
DISCONNECT CONNECTOR.
GROUND #3 = BLACK 18 AWG., PIN POSITION (F) OF MALE 23 PIN QUICK
DISCONNECT CONNECTOR.
GROUND #4 = BLACK 18 AWG., PIN POSITION (G) OF MALE 23 PIN QUICK
DISCONNECT CONNECTOR.
28) A 5-6 WATT, ½ AMP (MINIMUM) SOLAR PANEL WILL BE MOUNTED TO THE UPPER
SECTION OF THE LIGHT BAR, THE SOLAR PANEL MUST WORK WITH ALL BATTERIES,
HAVE HIGH PULSING DE-SULPHATION AT 22-28 KHZ, MAX DC VOLTAGE CHARGE OF
16.5 VOLTS AT DIRECT SUNLIGHT. MUST BE DESIGNED FOR RENEWAL AND MINIMUM
CHARGING OF BATTERIES, SOLAR PANEL CAN HAVE BETWEEN 80 AND 150 SQUARE
INCHES OF LIGHT COLLECTION AREA. THE SOLAR PANEL MUST INCLUDE THE SOLAR
PANEL REGULATOR. THE REGULATOR MUST HAVE A RED BLINKING LED THAT
DESIGNATES PROPER FUNCTION OF PANEL. ALL WIRING AND CONNECTORS MUST BE
INCLUDED AND BE INCORPORATED INTO THE LIGHT BAR WIRING HARNESS.
THE SOLAR PANEL WIRING FROM THE LIGHT BAR TO THE MALE 23 PIN QUICK
DISCONNECT PLUG WILL BE AS FOLLOWS:
RED = PIN POSITION (H) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.
BLACK = PIN POSITION (Z) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.
YELLOW = PIN POSITION (P) OF MALE 23 PIN QUICK DISCONNECT
CONNECTOR.
29) THE LEADS FROM THE SOLAR PANEL REGULATOR THAT CONNECT TO THE
VEHICLES BATTERY WILL BE (32) THIRTY TWO INCHES IN LENGTH WITH A PACKARD
DELPHI METRI PACK 150 SERIES SEALED TWO CAVITY FEMALE CONNECTOR THAT
HOUSES FEMALE TERMINAL SOCKETS (12) TWELVE INCHES FROM THE REGULATOR,
THE MALE 2 PIN CONNECTOR THAT HOUSES MALE TERMINAL PINS WILL HAVE THE
REMAINING (20) TWENTY INCHES OF RED/BLACK DUPLEX WIRE FOR CONNECTION TO
THE BATTERY TERMINALS.
TWO CAVITY CONNECTOR PIN OUTS AS FOLLOWS:
RED = PIN POSITION (A)
BLACK = PIN POSITION (B)
30) THE LEADS FROM THE SOLAR PANEL REGULATOR TO THE MALE THREE CAVITY
CONNECTOR THAT CONNECTS TO THE LIGHT BAR HARNESS WILL BE (18) EIGHTEEN
INCHES, THE CONNECTOR WILL BE A PACKARD DELPHI METRI PACK 150 SERIES
SEALED CONNECTOR THAT HOUSES THE MALE TERMINAL PINS.
THE THREE (3) CAVITY CONNECTOR PIN OUTS AS FOLLOWS:
RED = PIN POSITION (A)
BLACK = PIN POSITION (B)
YELLOW = PIN POSITION (C)
31) THE CABLE FROM THE LIGHT BAR EXIT HOLE TO THE ROOF TOP MOUNTED
DJU6200008501 PAGE 11 OF 2641
Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date
FEMALE QUICK DISCONNECT BULKHEAD CONNECTOR WILL BE 26 INCHES LONG, IT
WILL TERMINATE INTO A MALE 23 PIN CONNECTOR THAT HOUSES MALE TERMINAL
PINS, IT WILL BE A SEALED CABLE INCORPORATING ALL WIRING FOR THE LIGHT
MODULES AND THE SOLAR PANEL. THE CONNECTOR WILL BE A STRAIGHT PLUG THAT
WILL FIT INTO THE ROOF TOP MOUNTED BULKHEAD CONNECTOR WITH A TWIST TO
LOCK IN PLACE FEATURE. IT WILL ACCEPT 16-18 AWG AND THE 23 PINS WILL BE
DESIGNATED BY LETTERS OF THE ALPHABET FOR MATING TO THE PROPER SOCKETS
OF THE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR.
32) MUST INCLUDE ALL NECESSARY MOUNTING HARDWARE AND SEALS TO MOUNT
LIGHT BAR HARNESS THROUGH ROOF VIA THE ROOF TOP BULKHEAD CONNECTOR; THE
FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR THAT HOUSES THE FEMALE
SOCKET TERMINALS; THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD
CONNECTOR TO THE SIREN CONTROLLER ADAPTOR PLUG; THE WIRING FROM THE
FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR TO THE GROUND LUG RING
CONNECTOR AND THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD
CONNECTOR TO THE SOLAR PANEL REGULATOR ADAPTOR PLUG.
33) THE 23 SOCKET ROOF TOP MOUNTED BULKHEAD CONNECTOR IS A 90°, AERO-
DYNAMICALLY SHAPED PLUG. HEIGHT WILL BE NO MORE THAN 40 MM. AND WIDTH
WILL BE NO MORE THAN 75 MM. AND LENGTH WILL BE NO LONGER THAN 90 MM. IT
WILL HAVE A RUBBER GASKET FOR MOUNTING SEAL AND WILL HAVE A MINIMUM OF
FOUR SCREW MOUNTING POINTS FOR THROUGH ROOF MOUNTING. THE WIRE ACCESS
HOLE WILL BE 1 ¼ INCH. IT WILL ACCEPT FEMALE SOCKET TERMINALS AND THE
SOCKETS ARE CAPABLE OF ACCEPTING 16-18 AWG. THE QUICK DISCONNECT
RECEIVER OF THE CONNECTOR WILL RECEIVE THE MALE 23 PIN CONNECTOR. IT HAS
TWIST TO LOCK IN PLACE TABS FOR SECURE MATING TO THE MALE PLUG.
34) THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR TO
THE SIREN CONTROLLER ADAPTOR PLUG WILL BE (15) FIFTEEN FEET LONG. THE
SIREN CONTROLLER ADAPTOR PLUG WILL BE A PACKARD DELPHI METRI PACK 150
SERIES SEALED (6) SIX CAVITY CONNECTOR; IT WILL BE THE MALE END THAT
HOUSES THE MALE TERMINAL PINS.
THE SIX (6) CAVITY CONNECTOR PIN OUTS ARE AS FOLLOWS:
GREEN/BLACK = WIRE 1 =POSITION (A)
RED/WHITE = WIRE 2 = POSITION (B)
ORANGE/BLACK = WIRE 3 = POSITION (C)
ORANGE = WIRE 4 = POSITION (D)
BLUE = WIRE 5 =POSITION (E)
RED/BLACK = WIRE 6 =POSITION (F)
THE WIRE CONNECTIONS TO THE 23 SOCKET ROOF TOP MOUNTED BULKHEAD
CONNECTOR ARE AS FOLLOWS:
GREEN WITH BLACK = WIRE 1 =POSITION (V)
RED WITH WHITE = WIRE 2 = POSITION (J)
ORANGE WITH BLACK= WIRE 3 = POSITION (S)
ORANGE = WIRE 4 = POSITION (U)
BLUE = WIRE 5 =POSITION (M)
RED WITH BLACK = WIRE 6 =POSITION (K)
DJU6200008501 PAGE 12 OF 2641
Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date
35) THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR TO
THE SOLAR PANEL ADAPTOR PLUG WILL BE (16) SIXTEEN FEET LONG. THE SOLAR
PANEL ADAPTOR PLUG WILL BE A PACKARD DELPHI METRI PACK 150 SERIES SEALED
(3) THREE CAVITY CONNECTOR. IT WILL BE THE FEMALE END THAT HOUSES THE
FEMALE TERMINAL SOCKETS.
THE THREE (3) CAVITY FEMALE CONNECTOR PIN OUTS ARE AS FOLLOWS:
RED = PIN POSITION (A)
BLACK = PIN POSITION (B)
YELLOW = PIN POSITION (C)
THE WIRE CONNECTIONS TO THE 23 SOCKET ROOF TOP MOUNTED BULKHEAD
CONNECTOR ARE AS FOLLOWS:
RED = PIN POSITION (H)
BLACK = PIN POSITION (Z)
YELLOW = PIN POSITION (P)
36) THE GROUND WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD
CONNECTOR TO THE GROUND LUG RING TERMINAL WILL BE (17) SEVENTEEN FEET
LONG. THE (4) FOUR GROUND WIRES WILL TERMINATE INTO (1) ONE NON SHIELDED
RING CONNECTOR WITH A ¼ INCH EYELET. THE PIN POSITIONS OF THE GROUND
WIRES IN THE FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR ARE AS
FOLLOWS:
GROUND #1 = BLACK 18 AWG., PIN POSITION (D) OF FEMALE 23 SOCKET ROOF TOP
MOUNTED BULKHEAD CONNECTOR.
GROUND #2 = BLACK 18 AWG., PIN POSITION (E) OF FEMALE 23 SOCKET ROOF TOP
MOUNTED BULKHEAD CONNECTOR.
GROUND #3 = BLACK 18 AWG., PIN POSITION (F) OF FEMALE 23 SOCKET ROOF TOP
MOUNTED BULKHEAD CONNECTOR.
GROUND #4 = BLACK 18 AWG., PIN POSITION (G) OF FEMALE 23 SOCKET ROOF TOP
MOUNTED BULKHEAD CONNECTOR.
DJU6200008501 PAGE 13 OF 2641
Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date
00003 LMPCH10STD0001 20 EA 5000038103
LIGHTBAR,ALL,LED,STD,CH-IMPALA
THIS LIGHT BAR WILL FIT THE CHEVY IMPALA.
LENGTH: 48 INCHES, TOLERANCE: + OR - (2) TWO INCHES
INCLUDES STAINLESS STEEL GUTTER RAIL STYLE MOUNTS AND ACCOMPANYING
HARDWARE FOR ROOF TOP INSTALLATION. MUST INCLUDE INSTALLATION
INSTRUCTIONS AND
SIX (6) RIVETS
HEAD STYLE: Dome
RIVET MATERIAL: Stainless Steel
MANDREL MATERIAL: Stainless Steel
RIVET DIAMETER: 3/16 Inch
GRIP RANGE: 3/8 - 1/2 Inch
STANDARD LIGHT CONFIGURATION, LED, LIGHT BAR, W/5 WATT ½ AMP (MINIMUM)
SOLAR PANEL AND SOLAR PANEL REGULATOR W/LED INDICATOR, WITH 26 INCH
PIGTAIL TO ROOF TOP MOUNTED QUICK DISCONNECT BULKHEAD CONNECTOR, 23
POSITION ROOF TOP MOUNTED BULKHEAD CONNECTOR, AND ALL ACCOMPANYING
WIRING TO AND FROM ROOF TOP CONNECTOR AND SIREN CONTROLLER AND FROM ROOF
TOP CONNECTOR TO SOLAR PANEL REGULATOR.
1) MEETS ALL APPLICABLE SAE, FMVSS AND CALIFORNIA TITLE XIII STANDARDS
WHEN PROPERLY CONFIGURED.
2) ALL LED MODULES WILL BE CLEAR UNTIL ILLUMINATED AND WILL BE HIGH
INTENSITY LEDs.
3) FIVE YEAR WARRANTY MINIMUM.
4) LOW PROFILE MODULAR DESIGN.
5) CORROSION RESISTANT ALL ALUMINUM HOUSING WITH NO PLASTIC OR COMPOSITE
COVERS.
6) UV RESISTANT POLY CARBONATE LENS.
7) ABILITY TO INTEGRATE DIRECTIONAL INDICATORS FOR REAR FACING MODULES.
8) FULL 360° VISIBILITY.
9) MAINTENANCE FREE.
10) WILL OPERATE ON 12 VOLT NEGATIVE GROUND SYSTEM.
11) SOLID - STATE ELECTRONICS NOT EXCEEDING 12 AMPS AT FULL OPERATION.
12) ALL FORWARD AND REAR FACING MODULES WILL HAVE (6) LEDs MINIMUM PER
MODULE.
13) ALL CORNER MODULES WILL HAVE (12) LEDs MINIMUM PER MODULE.
14) TAKE DOWN MODULES WILL BE HIGH INTENSITY LEDs (CLEAR).
15) ALLEY MODULES WILL BE HIGH INTENSITY LEDs (CLEAR)
16) EACH CORNER WILL CONTAIN AT MINIMUM ONE 12 LED LIGHT HEAD MODULE.
17) FORWARD FACING OPTICAL INDICATORS WILL HAVE A MINIMUM OF FOUR, (6)
SIX LED LIGHT HEAD MODULES AND (2) TWO LED TAKE DOWN MODULES WITH A
MINIMUM OF (3) THREE HIGH INTENSITY LEDs.
18) TAKE DOWN LEDs WILL FLASH ALTERNATELY AND ACTIVATE WITH
FRONT LEDs. THIS FEATURE WILL BE OVERRIDDEN WHEN TAKE DOWNS ARE
DJU6200008501 PAGE 14 OF 2641
Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date
INDEPENDENTLY ACTIVATED.
19) REAR FACING OPTICAL INDICATORS WILL HAVE A MINIMUM OF SIX, (6) SIX
LED LIGHT HEAD MODULES.
20) DRIVER SIDE EXIT HOLE FOR HARNESS.
21) THE DRIVER SIDE OUTBOARD FORWARD FACING RED MODULE SHALL BE
PROGRAMMABLE TO INCLUDE STEADY # BURN MODE. THIS WILL BE PROGRAMMED AT
INSTALLATION IF CALIFORNIA TITLE XIII IS APPLICABLE.
22) THE FORWARD FACING MODULES FROM CENTER OUTWARD: TO THE
DRIVER SIDE WILL BE TAKE DOWN, FLASHING RED, FLASHING PROGRAMMABLE
RED. TO THE PASSENGER SIDE WILL BE TAKE DOWN, FLASHING BLUE, FLASHING
BLUE.
23) THE REAR FACING MODULES FROM CENTER OUTWARD: TO THE DRIVER SIDE
WILL BE FLASHING RED, FLASHING RED, FLASHING AMBER. TO THE PASSENGER
SIDE WILL BE FLASHING BLUE, FLASHING BLUE, FLASHING AMBER.
24) THE DRIVER SIDE CORNERS (FRONT AND REAR) WILL BE FLASHING RED.
25) THE PASSENGER SIDE CORNERS (FRONT AND REAR) WILL BE FLASHING BLUE.
26) LIGHT BAR MODULE PLACEMENT DESCRIPTION:
FRONT OF LIGHT BAR FROM DRIVER SIDE TO PASSENGER SIDE:
PROGRAMMABLE DRIVER RED, DRIVER RED, DRIVER CLEAR TAKE DOWN, PASSENGER
CLEAR TAKE DOWN, PASSENGER BLUE, PASSENGER BLUE
BACK OF LIGHT BAR FROM DRIVERS SIDE TO PASSENGER SIDE:
DRIVER AMBER, DRIVER RED, DRIVER RED
PASSENGER BLUE, PASSENGER BLUE, PASSENGER AMBER.
DRIVERS SIDE CORNER OF LIGHT BAR:
CORNER RED, LEFT ALLEY, CORNER RED.
PASSENGER SIDE CORNER OF LIGHT BAR:
CORNER BLUE, RIGHT ALLEY, CORNER BLUE.
27) LIGHT HEAD ACTIVATION SPECIFICATIONS AND WIRE COLORS ARE AS FOLLOWS:
WIRE #1 = GREEN/BLACK 18 AWG., WILL ACTIVATE ALL REAR FACING LIGHT
MODULES INCLUDING THE REAR CORNERS, PIN POSITION (V) OF MALE 23 PIN
QUICK DISCONNECT CONNECTOR.
WIRE #2 = RED/WHITE 18 AWG., WILL ACTIVATE ALL FORWARD FACING LIGHT
MODULES INCLUDING THE FRONT CORNERS, PIN POSITION (J) OF MALE 23 PIN
QUICK DISCONNECT CONNECTOR.
WIRE #3 = ORANGE/BLACK 18 AWG., WILL ACTIVATE THE LEFT ALLEY LIGHT
MODULE, PIN POSITION (S) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.
WIRE #4 = ORANGE 18 AWG., WILL ACTIVATE THE RIGHT ALLEY LIGHT MODULE,
PIN POSITION (U) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.
WIRE #5 = BLUE 18 AWG., WILL ACTIVATE BOTH TAKE DOWN LIGHT MODULES, PIN
POSITION (M) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.
WIRE #6 = RED/BLACK 18 AWG., THIS WILL ACTIVATE THE PROGRAMMABLE DRIVER
SIDE OUTBOARD LIGHT MODULE FOR STEADY BURN MODE ON CALIFORNIA TITLE XIII
DJU6200008501 PAGE 15 OF 2641
Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date
COMPLIANT VEHICLES. THIS MODULE WILL BE PROGRAMMED AT INSTALLATION. IT
WILL BE REQUIRED TO BE FIELD PROGRAMMABLE, PIN POSITION (K) OF MALE 23
PIN QUICK DISCONNECT CONNECTOR.
GROUND #1 = BLACK 18 AWG., PIN POSITION (D) OF MALE 23 PIN QUICK
DISCONNECT CONNECTOR.
GROUND #2 = BLACK 18 AWG., PIN POSITION (E) OF MALE 23 PIN QUICK
DISCONNECT CONNECTOR.
GROUND #3 = BLACK 18 AWG., PIN POSITION (F) OF MALE 23 PIN QUICK
DISCONNECT CONNECTOR.
GROUND #4 = BLACK 18 AWG., PIN POSITION (G) OF MALE 23 PIN QUICK
DISCONNECT CONNECTOR.
28) A 5-6 WATT, ½ AMP (MINIMUM) SOLAR PANEL WILL BE MOUNTED TO THE UPPER
SECTION OF THE LIGHT BAR, THE SOLAR PANEL MUST WORK WITH ALL BATTERIES,
HAVE HIGH PULSING DE-SULPHATION AT 22-28 KHZ, MAX DC VOLTAGE CHARGE OF
16.5 VOLTS AT DIRECT SUNLIGHT. MUST BE DESIGNED FOR RENEWAL AND MINIMUM
CHARGING OF BATTERIES, SOLAR PANEL CAN HAVE BETWEEN 80 AND 150 SQUARE
INCHES OF LIGHT COLLECTION AREA. THE SOLAR PANEL MUST INCLUDE THE SOLAR
PANEL REGULATOR. THE REGULATOR MUST HAVE A RED BLINKING LED THAT
DESIGNATES PROPER FUNCTION OF PANEL. ALL WIRING AND CONNECTORS MUST BE
INCLUDED AND BE INCORPORATED INTO THE LIGHT BAR WIRING HARNESS.
THE SOLAR PANEL WIRING FROM THE LIGHT BAR TO THE MALE 23 PIN QUICK
DISCONNECT PLUG WILL BE AS FOLLOWS:
RED = PIN POSITION (H) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.
BLACK = PIN POSITION (Z) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.
YELLOW = PIN POSITION (P) OF MALE 23 PIN QUICK DISCONNECT
CONNECTOR.
29) THE LEADS FROM THE SOLAR PANEL REGULATOR THAT CONNECT TO THE
VEHICLES BATTERY WILL BE (32) THIRTY TWO INCHES IN LENGTH WITH A PACKARD
DELPHI METRI PACK 150 SERIES SEALED TWO CAVITY FEMALE CONNECTOR THAT
HOUSES FEMALE TERMINAL SOCKETS (12) TWELVE INCHES FROM THE REGULATOR,
THE MALE 2 PIN CONNECTOR THAT HOUSES MALE TERMINAL PINS WILL HAVE THE
REMAINING (20) TWENTY INCHES OF RED/BLACK DUPLEX WIRE FOR CONNECTION TO
THE BATTERY TERMINALS.
TWO CAVITY CONNECTOR PIN OUTS AS FOLLOWS:
RED = PIN POSITION (A)
BLACK = PIN POSITION (B)
30) THE LEADS FROM THE SOLAR PANEL REGULATOR TO THE MALE THREE CAVITY
CONNECTOR THAT CONNECTS TO THE LIGHT BAR HARNESS WILL BE (18) EIGHTEEN
INCHES, THE CONNECTOR WILL BE A PACKARD DELPHI METRI PACK 150 SERIES
SEALED CONNECTOR THAT HOUSES THE MALE TERMINAL PINS.
THE THREE (3) CAVITY CONNECTOR PIN OUTS AS FOLLOWS:
RED = PIN POSITION (A)
BLACK = PIN POSITION (B)
YELLOW = PIN POSITION (C)
31) THE CABLE FROM THE LIGHT BAR EXIT HOLE TO THE ROOF TOP MOUNTED
DJU6200008501 PAGE 16 OF 2641
Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date
FEMALE QUICK DISCONNECT BULKHEAD CONNECTOR WILL BE 26 INCHES LONG, IT
WILL TERMINATE INTO A MALE 23 PIN CONNECTOR THAT HOUSES MALE TERMINAL
PINS, IT WILL BE A SEALED CABLE INCORPORATING ALL WIRING FOR THE LIGHT
MODULES AND THE SOLAR PANEL. THE CONNECTOR WILL BE A STRAIGHT PLUG THAT
WILL FIT INTO THE ROOF TOP MOUNTED BULKHEAD CONNECTOR WITH A TWIST TO
LOCK IN PLACE FEATURE. IT WILL ACCEPT 16-18 AWG AND THE 23 PINS WILL BE
DESIGNATED BY LETTERS OF THE ALPHABET FOR MATING TO THE PROPER SOCKETS
OF THE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR.
32) MUST INCLUDE ALL NECESSARY MOUNTING HARDWARE AND SEALS TO MOUNT
LIGHT BAR HARNESS THROUGH ROOF VIA THE ROOF TOP BULKHEAD CONNECTOR; THE
FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR THAT HOUSES THE FEMALE
SOCKET TERMINALS; THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD
CONNECTOR TO THE SIREN CONTROLLER ADAPTOR PLUG; THE WIRING FROM THE
FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR TO THE GROUND LUG RING
CONNECTOR AND THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD
CONNECTOR TO THE SOLAR PANEL REGULATOR ADAPTOR PLUG.
33) THE 23 SOCKET ROOF TOP MOUNTED BULKHEAD CONNECTOR IS A 90°, AERO-
DYNAMICALLY SHAPED PLUG. HEIGHT WILL BE NO MORE THAN 40 MM. AND WIDTH
WILL BE NO MORE THAN 75 MM. AND LENGTH WILL BE NO LONGER THAN 90 MM. IT
WILL HAVE A RUBBER GASKET FOR MOUNTING SEAL AND WILL HAVE A MINIMUM OF
FOUR SCREW MOUNTING POINTS FOR THROUGH ROOF MOUNTING. THE WIRE ACCESS
HOLE WILL BE 1 ¼ INCH. IT WILL ACCEPT FEMALE SOCKET TERMINALS AND THE
SOCKETS ARE CAPABLE OF ACCEPTING 16-18 AWG. THE QUICK DISCONNECT
RECEIVER OF THE CONNECTOR WILL RECEIVE THE MALE 23 PIN CONNECTOR. IT HAS
TWIST TO LOCK IN PLACE TABS FOR SECURE MATING TO THE MALE PLUG.
34) THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR TO
THE SIREN CONTROLLER ADAPTOR PLUG WILL BE (15) FIFTEEN FEET LONG. THE
SIREN CONTROLLER ADAPTOR PLUG WILL BE A PACKARD DELPHI METRI PACK 150
SERIES SEALED (6) SIX CAVITY CONNECTOR; IT WILL BE THE MALE END THAT
HOUSES THE MALE TERMINAL PINS.
THE SIX (6) CAVITY CONNECTOR PIN OUTS ARE AS FOLLOWS:
GREEN/BLACK = WIRE 1 =POSITION (A)
RED/WHITE = WIRE 2 = POSITION (B)
ORANGE/BLACK = WIRE 3 = POSITION (C)
ORANGE = WIRE 4 = POSITION (D)
BLUE = WIRE 5 =POSITION (E)
RED/BLACK = WIRE 6 =POSITION (F)
THE WIRE CONNECTIONS TO THE 23 SOCKET ROOF TOP MOUNTED BULKHEAD
CONNECTOR ARE AS FOLLOWS:
GREEN WITH BLACK = WIRE 1 =POSITION (V)
RED WITH WHITE = WIRE 2 = POSITION (J)
ORANGE WITH BLACK= WIRE 3 = POSITION (S)
ORANGE = WIRE 4 = POSITION (U)
BLUE = WIRE 5 =POSITION (M)
RED WITH BLACK = WIRE 6 =POSITION (K)
DJU6200008501 PAGE 17 OF 2641
Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date
35) THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR TO
THE SOLAR PANEL ADAPTOR PLUG WILL BE (16) SIXTEEN FEET LONG. THE SOLAR
PANEL ADAPTOR PLUG WILL BE A PACKARD DELPHI METRI PACK 150 SERIES SEALED
(3) THREE CAVITY CONNECTOR. IT WILL BE THE FEMALE END THAT HOUSES THE
FEMALE TERMINAL SOCKETS.
THE THREE (3) CAVITY FEMALE CONNECTOR PIN OUTS ARE AS FOLLOWS:
RED = PIN POSITION (A)
BLACK = PIN POSITION (B)
YELLOW = PIN POSITION (C)
THE WIRE CONNECTIONS TO THE 23 SOCKET ROOF TOP MOUNTED BULKHEAD
CONNECTOR ARE AS FOLLOWS:
RED = PIN POSITION (H)
BLACK = PIN POSITION (Z)
YELLOW = PIN POSITION (P)
36) THE GROUND WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD
CONNECTOR TO THE GROUND LUG RING TERMINAL WILL BE (17) SEVENTEEN FEET
LONG. THE (4) FOUR GROUND WIRES WILL TERMINATE INTO (1) ONE NON SHIELDED
RING CONNECTOR WITH A ¼ INCH EYELET. THE PIN POSITIONS OF THE GROUND
WIRES IN THE FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR ARE AS
FOLLOWS:
GROUND #1 = BLACK 18 AWG., PIN POSITION (D) OF FEMALE 23 SOCKET ROOF TOP
MOUNTED BULKHEAD CONNECTOR.
GROUND #2 = BLACK 18 AWG., PIN POSITION (E) OF FEMALE 23 SOCKET ROOF TOP
MOUNTED BULKHEAD CONNECTOR.
GROUND #3 = BLACK 18 AWG., PIN POSITION (F) OF FEMALE 23 SOCKET ROOF TOP
MOUNTED BULKHEAD CONNECTOR.
GROUND #4 = BLACK 18 AWG., PIN POSITION (G) OF FEMALE 23 SOCKET ROOF TOP
MOUNTED BULKHEAD CONNECTOR.
DJU6200008501 PAGE 18 OF 2641
Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date
00004 LMPCH17STD0001 20 EA 5000038103
49"LIGHTBAR,ALL-LED,STD,CHEVY-CAPRICE
MATERIAL:
THIS IS A ALL LED LIGHT BAR FOR THE CHEVY CAPRICE
SPECIFICATIONS:
Length: 49 Inches, Tolerance: + Or - (2) Two Inches
Includes Stainless Steel Gutter Rail Style Mounts And
Accompanying Hardware For Roof Top Installation And
SIX (6) RIVETS
HEAD STYLE: Dome
RIVET MATERIAL: Stainless Steel
MANDREL MATERIAL: Stainless Steel
RIVET DIAMETER: 3/16 Inch
GRIP RANGE: 3/8 - 1/2 Inch
Standard Light Configuration
All LED Light Bar
W/5 Watt ½ Amp (Minimum) Solar Panel And Solar Panel
Regulator W/Led Indicator
26 Inch Pigtail To Roof Top Mounted Quick Disconnect Bulkhead
Connector
23 Position Roof Top Mounted Bulkhead Connector
All Accompanying Wiring To And From Roof Top Connector
And Siren Controller And From Roof Top Connector To Solar
Panel Regulator.
1) Meets All Applicable SAE, FMVSS And California Title XIII
Standards When Properly Configured.
2) All LED Modules Will Be Clear Until Illuminated And Will Be
High Intensity Leds.
3) Five Year Warranty Minimum.
4) Low Profile Modular Design.
5) CORROSION RESISTANT ALL ALUMINUM HOUSING WITH NO PLASTIC OR COMPOSITE
COVERS.
6) UV Resistant Poly Carbonate Lens.
7) Ability To Integrate Directional Indicators For Rear
Facing Modules.
8) Full 360° Visibility.
9) Maintenance Free.
10) Will Operate On 12 Volt Negative Ground System.
11) Solid - State Electronics Not Exceeding 12 Amps At
Full Operation.
12) All Forward And Rear Facing Modules Will Have (6) LEDs
Minimum Per Module.
13) All Corner Modules Will Have (12) LEDs Minimum Per Module.
DJU6200008501 PAGE 19 OF 2641
Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date
14) Take Down Modules Will Be High Intensity LEDs (Clear).
15) Alley Modules Will Be High Intensity LEDs (Clear)
16) Each Corner Will Contain At Minimum One 12 LED Light
Head Module.
17) Forward Facing Optical Indicators Will Have A Minimum Of
Four, (6) Six LED Light Head Modules And (2) Two LED Take Down
Modules With A Minimum Of (3) Three High Intensity LEDs.
18) Take Down LEDs Will Flash Alternately And Activate With
Front LEDs. This Feature Will Be Overridden When Take Downs Are
Independently Activated.
19) Rear Facing Optical Indicators Will Have A Minimum Of Six,
(6) Six LED Light Head Modules.
20) Driver Side Exit Hole For Harness.
21) The Driver Side Outboard Forward Facing Red Module Shall Be
Programmable To Include Steady # Burn Mode. This Will Be
Programmed At Installation If California Title XIII Is Applicable.
22) The Forward Facing Modules From Center Outward: To The
Driver Side Will Be Take Down, Flashing Red, Flashing
Programmable Red. To The Passenger Side Will Be Take Down, Flashing Blue, Flashing Blue.
23) The Rear Facing Modules From Center Outward: To The Driver
Side Will Be Flashing Red, Flashing Red, Flashing Amber. To The
Passenger Side Will Be Flashing Blue, Flashing Blue, Flashing Amber.
24) The Driver Side Corners (Front And Rear) Will Be Flashing Red.
25) The Passenger Side Corners (Front And Rear) Will Be
Flashing Blue.
26) Light Bar Module Placement Description:
Front Of Light Bar From Driver Side To Passenger Side:
Programmable Driver Red, Driver Red, Driver Clear Take Down, Passenger Clear Take Down, Passenger Blue, Passenger Blue
Back Of Light Bar From Drivers Side To Passenger Side:
Driver Amber, Driver Red, Driver Red
Passenger Blue, Passenger Blue, Passenger Amber.
Drivers Side Corner Of Light Bar:
Corner Red, Left Alley, Corner Red.
Passenger Side Corner Of Light Bar:
Corner Blue, Right Alley, Corner Blue.
27) Light Head Activation Specifications And Wire Colors Are
As Follows:
Wire #1 = Green/Black 18 Awg., Will Activate All Rear Facing Light
Modules Including The Rear Corners, Pin Position (V) Of Male 23 Pin
Quick Disconnect Connector.
Wire #2 = Red/White 18 Awg., Will Activate All Forward Facing Light
DJU6200008501 PAGE 20 OF 2641
Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date
Modules Including The Front Corners, Pin Position (J) Of Male 23 Pin
Quick Disconnect Connector.
Wire #3 = Orange/Black 18 Awg., Will Activate The Left Alley Light
Module, Pin Position (S) Of Male 23 Pin Quick Disconnect Connector.
Wire #4 = Orange 18 Awg., Will Activate The Right Alley Light Module, Pin Position (U) Of Male 23 Pin Quick Disconnect Connector.
Wire #5 = Blue 18 Awg., Will Activate Both Take Down Light Modules, Pin Position (M) Of Male 23 Pin Quick Disconnect Connector.
Wire #6 = Red/Black 18 Awg., This Will Activate The Programmable
Driver Side Outboard Light Module For Steady Burn Mode On
California Title XIII Compliant Vehicles. This Module Will Be
Programmed At Installation. It Will Be Required To Be Field
Programmable, Pin Position (K) Of Male 23 Pin Quick Disconnect
Connector.
Ground #1 = Black 18 Awg., Pin Position (D) Of Male 23 Pin Quick
Disconnect Connector.
Ground #2 = Black 18 Awg., Pin Position (E) Of Male 23 Pin Quick
Disconnect Connector.
Ground #3 = Black 18 Awg., Pin Position (F) Of Male 23 Pin Quick
Disconnect Connector.
Ground #4 = Black 18 Awg., Pin Position (G) Of Male 23 Pin Quick
Disconnect Connector.
28) A 5-6 Watt, ½ Amp (Minimum) Solar Panel Will Be Mounted To
The Upper Section Of The Light Bar, The Solar Panel Must Work
With All Batteries, Have High Pulsing De-Sulphation At 22-28 Khz, Max Dc Voltage Charge Of 16.5 Volts At Direct Sunlight. Must Be
Designed For Renewal And Minimum Charging Of Batteries, Solar
Panel Can Have Between 80 And 150 Square Inches Of Light
Collection Area. The Solar Panel Must Include The Solar
Panel Regulator. The Regulator Must Have A Red Blinking Led That
Designates Proper Function Of Panel. All Wiring And Connectors
Must Be Included And Be Incorporated Into The Light Bar
Wiring Harness.
The Solar Panel Wiring From The Light Bar To The Male 23 Pin
Quick Disconnect Plug Will Be As Follows:
Red = Pin Position (H) Of Male 23 Pin Quick Disconnect Connector.
Black = Pin Position (Z) Of Male 23 Pin Quick Disconnect Connector.
Yellow = Pin Position (P) Of Male 23 Pin Quick Disconnect
Connector.
29) The Leads From The Solar Panel Regulator That Connect To The
Vehicles Battery Will Be (32) Thirty Two Inches In Length With A
Packard Delphi Metri Pack 150 Series Sealed Two Cavity Female
Connector That Houses Female Terminal Sockets (12) Twelve Inches
From The Regulator, The Male 2 Pin Connector That Houses Male
Terminal Pins Will Have The Remaining (20) Twenty Inches Of
Red/Black Duplex Wire For Connection To The Battery Terminals.
Two Cavity Connector Pin Outs As Follows:
DJU6200008501 PAGE 21 OF 2641
Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date
Red = Pin Position (A)
Black = Pin Position (B)
30) The Leads From The Solar Panel Regulator To The Male Three
Cavity Connector That Connects To The Light Bar Harness Will Be
(18) Eighteen Inches, The Connector Will Be A Packard Delphi
Metri Pack 150 Series Sealed Connector That Houses The Male
Terminal Pins.
The Three (3) Cavity Connector Pin Outs As Follows:
Red = Pin Position (A)
Black = Pin Position (B)
Yellow = Pin Position (C)
31) The Cable From The Light Bar Exit Hole To The Roof Top Mounted
Female Quick Disconnect Bulkhead Connector Will Be 26 Inches Long, It Will Terminate Into A Male 23 Pin Connector That Houses Male
Terminal Pins, It Will Be A Sealed Cable Incorporating All Wiring For
The Light Modules And The Solar Panel. The Connector Will Be A
Straight Plug That Will Fit Into The Roof Top Mounted Bulkhead
Connector With A Twist To Lock In Place Feature. It Will Accept
16-18 Awg And The 23 Pins Will Be Designated By Letters Of The
Alphabet For Mating To The Proper Sockets Of The 23 Socket Roof
Top Bulkhead Connector.
32) Must Include All Necessary Mounting Hardware And Seals To
Mount Light Bar Harness Through Roof Via The Roof Top Bulkhead
Connector; The Female 23 Socket Roof Top Bulkhead Connector
That Houses The Female Socket Terminals; The Wiring From The
Female 23 Socket Roof Top Bulkhead Connector To The Siren
Controller Adaptor Plug; The Wiring From The Female 23 Socket
Roof Top Bulkhead Connector To The Ground Lug Ring
Connector And The Wiring From The Female 23 Socket Roof Top
Bulkhead Connector To The Solar Panel Regulator Adaptor Plug.
33) The 23 Socket Roof Top Mounted Bulkhead Connector Is A 90°, Aero-Dynamically Shaped Plug. Height Will Be No More Than
40 mm. And Width Will Be No More Than 75 mm. And Length Will
Be No Longer Than 90 mm. It Will Have A Rubber Gasket For
Mounting Seal And Will Have A Minimum Of Four Screw
Mounting Points For Through Roof Mounting. The Wire Access
Hole Will Be 1 ¼ Inch. It Will Accept Female Socket Terminals And
The Sockets Are Capable Of Accepting 16-18 Awg.