1. REQUSITION NUMBER

5000038103

2. CONTRACT NO. 3.AWARD/EFFECTIVE DATE 4. ORDER NUMBER 5. SOLICITATION NUMBER

EP2864-16

6. SOLICITATION ISSUE DATE

03/21/2016

7. FOR SOLICITATION

INFORMATION CALL:

a. NAME

Sheila D. Gonzales

b. TELEPHONE NUMBER (No collect calls)

512-321-3903

8. OFFER DUE DT/LOCAL TIME

2:00PM

9. ISSUED BY CODE

UNICOR, FPI Central Office UNICOR FPI Central Office Washington, DC 20534

10. THIS AQUISITION IS

UNRESTRICTED

X SET ASIDE100 % FOR

X SMALL BUSINESS

SMALL DISADV.BUSINESS

8(A)

SIC: 3714

SIZE STANDARD: 500 Emp.

11. DELIVERY FOR FOB

DESTINATION UNLESS

BLOCK IS MARKED

SEE SCHEDULE

12. DISCOUNT TERMS

13a. THIS CONTRACT IS A RATED ORDER

UNDER DPAS (15 CFR 700)

13b. RATING

14. METHOD OF SOLICITATION

RFQ IFB X RFP

16. ADMINISTERED BY CODE

UNICOR, FPI Central Office UNICOR FPI Central Office Washington, DC 20534

17a. CONTRACTOR/OFFEROR CODE 999999999 FACILITY CODE

TELEPHONE NO. TIN:

RFQ: 6200008501

17b. CHECK IF REMITANCE IS DIFFERENT AND PUT SUCH ADDRESS IN OFFER

18a. PAYMENT WILL BE MADE BY CODE

18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a UNLESS BLOCK BELOW

IS CHECKED SEE ADDENDUM

19.

ITEM NO.

20.

SCHEDULE OF SUPPLIES/SERVICES

See Section B

21.

QUANTITY

22.

UNIT

23.

UNIT PRICE

24.

AMOUNT

25. ACCOUNTING AND APPROPRIATION DATA 26. TOTAL AWARD AMOUNT (For Govt. Use Only)

X 27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1, 52.212-4. FAR 52.212-3 AND 52.212-5 ARE ATTACHED. ADDENDA X ARE ARE NOT ATTACHED

27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA ARE ARE NOT ATTACHED

28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN 1 COPIES

TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND DELIVER ALL ITEMS SET

X FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY ADDITIONAL SHEETS SUBJECT TO

THE TERMS AND CONDITIONS SPECIFIED HEREIN.

29. AWARD OF CONTRACT: REFERENCE __________________________________

OFFER DATED __________________. YOUR OFFER ON SOLICITATION (BLOCK 5),

INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE SET FORTH HERIN,

ACCEPTED AS TO ITEMS:

30a. SIGNATURE OF OFFEROR/CONTRACTOR

30b. NAME AND TITLE OF SIGNER (TYPE OR PRINT) 30c. DATE SIGNED

31a. UNITED STATES OF AMERICA (SIGNATURE OF CONTRACTING OFFICER)

31b. NAME OF CONTRACTING OFFICER (TYPE OR PRINT)

Sheila D. Gonzales 512-321-3903

31c. DATE SIGNED

03/24/2016

32a. QUANTITY IN COLUMN 21 HAS BEEN

RECEIVED INSPECTED ACCEPTED, AND CONFORMS TO THE

CONTRACT EXCEPT AS NOTED

32b. SIGNATURE OF AUTHORIZED GOVT. REPRESENTATIVE 32c. DATE

33. SHIP NUMBER

PARTIAL FINAL

34. VOUCHER NUMBER 35. AMOUNT VERIFIED

CORRECT FOR

36. PAYMENT

COMPLETE PARTIAL FINAL

37. CHECK NUMBER

38. S/R ACCOUNT NUMBER

42a. RECEIVED BY (Print)

42b. RECEIVED AT (Location)

42c. DATE REC'D (YY/MM/DD)

39. S/R VOUCHER NUMBER 40. PAID BY

41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT

41b. SIGNATURE AND TITLE OF CERTIFYING OFFICER 41c. DATE

42d. TOTAL CONTAINERS

15. DELIVER TO CODE

AUTHORIZED FOR LOCAL REPRODUCTION STANDARD FORM 1449 (10-95)

Prescribed by GSA - FAR (48 CFR) 53.212

PAGE 1 OF

SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS

OFFEROR TO COMPLETE BLOCKS 12,17,23,24 & 30

Terms of delivery: DST

TERMS OF DELIVERY ARE F.O.B. DESTINATION TO:

UNICOR Federal Prison Industries

1341 Hwy. 95 N.

Bastrop, TX 78602

UNICOR Federal Prison Industries

8500 Doniphan Dr.

Anthony, TX 79821

UNICOR Federal Prison Industries

4200 Bureau Rd. North

Terre Haute, IN 47802

UNICOR Federal Prison Industries

13777 Air Expressway Blvd.

Victorville, CA 92394

UNICOR Federal Prison Industries

201 FCI Lane

Glenville, WV 26351

Solicitation is issued as a five (5) year firm fixed price requirements type contract with Economic Price Adjustment for PCU441310441310 Automotive Parts and Accessories.

Offerors which do not agree with the Producer Price Index listed above are required to submit the price index that they believe is correct to the contracting officer at least five (5) calendar days prior to the due date for offers.

The index submitted will be evaluated, and changed by amendment to the solicitation if necessary.

PPI #____________________________________________

SOLICITATION IS 100% SET-ASIDE FOR SMALL BUSINESS.

QUESTIONS PERTAINING TO THIS SOLICITATION WILL ONLY BE ADDRESSED IN WRITING VIA EMAIL TO: Sheila.gonzales2@usdoj.gov.

QUESTIONS MUST BE RECEIVED BY APRIL 1, 2016. ANY QUESTIONS RECEIVED AFTER THIS DATE WILL NOT BE ADDRESSED. NO PHONE

CALLS PLEASE.

For a list, description and total estimated quantities of all items, refer to Section B.

Offerors ARE REQUIRED to submit one (1) each of the following FPI stock numbers: SWH0559PI - Siren Controller for

2016 Ford F150; LMPFD46STD0001 - Standard Lightbar for 2016 Ford F150; LMPFD46STD0002 - Lightbar with Traffic Advisor for 2016 Ford F150; LMP2386 - Red Intersection Light with Bezel; LMP2387 - Blue Intersection Light with Bezel; LMP1098

- Universal Full Visor Light; LMP2453 - Full Visor Light for 2016 Ford F150; and SPK0021PI - Speaker for 2016 Ford

F150, for technical evaluation to verify form, fit and function of the material. Contractors are required to submit the material by the closing date, Monday, April 25, 2016 at 2:00 p.m. CST. The shipping address for the material is:

UNICOR, 1341 Hwy 95 N., Bastrop, TX 78602, ATTN: Sheila D. Gonzales, Contract Specialist. Material that is not received by the closing date and time will not be evaluated and the proposal will not be considered further for award.

Please note solicitation EP2864-16 and your company's name/address on the packing slip for the material that is sent.

Contractors are responsible for the total cost of the sample, including shipping of the material for evaluation.

Contractors must provide a pre-paid return label so UNICOR can return the product after evaluation.

DJU6200008501 PAGE 2 OF 2641

Request For Quote

UNICOR's desired delivery is 30 days or sooner after issuance of each delivery order. Vendors are required to provide their best manufacturing/delivery time for evaluation, and delivery schedule will be established at time of award.

Delivery orders will be issued in accordance with 52.216-19.

Vendors shall submit signed and dated offers either by facsimile or overnight delivery (FedEx, UPS, etc.). Facsimile number is 352-330-8293. Any of the overnight delivery carriers will be accepted with delivery to: UNICOR Federal

Prison Industries, 1341 Hwy. 95 N., Bastrop, TX 78602 Attn: Sheila D. Gonzales. Offers shall be submitted on the

SF1449. OMB Clearance 1103-0018.

The date and time for receipt of proposals is Monday, April 25, 2016 at 2:00 p.m. CST. Offer must indicate

Solicitation No. EP2864-16, time specified for receipt of offer, name, address and telephone number of offeror, technical description of the items being offered in sufficient detail to evaluate compliance with the requirements in the solicitation, terms of any expressed warranty, price and any discount terms. Offer must include acknowledgment of all amendments, if any.

THE FOLLOWING INFORMATION IS REQUIRED TO BE COMPLETED BY THE OFFEROR:

VENDOR'S DUN & BRADSTREET NUMBER:_______________________________

VENDOR'S POINT OF CONTACT: _____________________________________

VENDOR'S TELEPHONE & FAX NUMBER: _______________________________

VENDOR'S EMAIL ADDRESS: ________________________________________

VENDOR'S BUSINESS SIZE (i.e. SMALL, LARGE, ETC.): ________________

By submission of an offer, the offeror acknowledges the requirement that a prospective awardee shall be registered in the SAM database (System Award Management) prior to award, during performance and through final payment of any contract resulting from this solicitation.

_______________________________________________ Signature

The Administrative Contracting officer is Sheila D. Gonzales at Sheila.gonzales2@usdoj.gov.

SECTION B

SUPPLIES OR SERVICES AND PRICES/COSTS

Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date

DJU6200008501 PAGE 3 OF 2641

SECTION B

SUPPLIES OR SERVICES AND PRICES/COSTS

Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date

00001 LMPCH100STD0001 500 EA 5000038103

LIGHTBAR,ALL,LED,STD,CH-TAHOE

THIS LIGHT BAR WILL FIT THE CHEVY TAHOE.

LENGTH: 54 INCHES, TOLERANCE: + OR - (2) TWO INCHES

INCLUDES STAINLESS STEEL GUTTER RAIL STYLE MOUNTS AND ACCOMPANYING

HARDWARE FOR ROOF TOP INSTALLATION. MUST INCLUDE INSTALLATION

INSTRUCTIONS AND

SIX (6) RIVETS

HEAD STYLE: Dome

RIVET MATERIAL: Stainless Steel

MANDREL MATERIAL: Stainless Steel

RIVET DIAMETER: 3/16 Inch

GRIP RANGE: 3/8 - 1/2 Inch

STANDARD LIGHT CONFIGURATION, LED, LIGHT BAR, W/5 WATT ½ AMP (MINIMUM)

SOLAR PANEL AND SOLAR PANEL REGULATOR W/LED INDICATOR, WITH 26 INCH

PIGTAIL TO ROOF TOP MOUNTED QUICK DISCONNECT BULKHEAD CONNECTOR, 23

POSITION ROOF TOP MOUNTED BULKHEAD CONNECTOR, AND ALL ACCOMPANYING

WIRING TO AND FROM ROOF TOP CONNECTOR AND SIREN CONTROLLER AND FROM ROOF

TOP CONNECTOR TO SOLAR PANEL REGULATOR.

1) MEETS ALL APPLICABLE SAE, FMVSS AND CALIFORNIA TITLE XIII STANDARDS

WHEN PROPERLY CONFIGURED.

2) ALL LED MODULES WILL BE CLEAR UNTIL ILLUMINATED AND WILL BE HIGH

INTENSITY LEDs.

3) FIVE YEAR WARRANTY MINIMUM.

4) LOW PROFILE MODULAR DESIGN.

5) CORROSION RESISTANT ALL ALUMINUM HOUSING WITH NO PLASTIC OR COMPOSITE

COVERS.

6) UV RESISTANT POLY CARBONATE LENS.

7) ABILITY TO INTEGRATE DIRECTIONAL INDICATORS FOR REAR FACING MODULES.

8) FULL 360° VISIBILITY.

9) MAINTENANCE FREE.

10) WILL OPERATE ON 12 VOLT NEGATIVE GROUND SYSTEM.

11) SOLID - STATE ELECTRONICS NOT EXCEEDING 12 AMPS AT FULL OPERATION.

12) ALL FORWARD AND REAR FACING MODULES WILL HAVE (6) LEDs MINIMUM PER

MODULE.

13) ALL CORNER MODULES WILL HAVE (12) LEDs MINIMUM PER MODULE.

14) TAKE DOWN MODULES WILL BE HIGH INTENSITY LEDs (CLEAR).

15) ALLEY MODULES WILL BE HIGH INTENSITY LEDs (CLEAR)

16) EACH CORNER WILL CONTAIN AT MINIMUM ONE 12 LED LIGHT HEAD MODULE.

17) FORWARD FACING OPTICAL INDICATORS WILL HAVE A MINIMUM OF FOUR, (6)

SIX LED LIGHT HEAD MODULES AND (2) TWO LED TAKE DOWN MODULES WITH A

MINIMUM OF (3) THREE HIGH INTENSITY LEDs.

18) TAKE DOWN LEDs WILL FLASH ALTERNATELY AND ACTIVATE WITH

FRONT LEDs. THIS FEATURE WILL BE OVERRIDDEN WHEN TAKE DOWNS ARE

DJU6200008501 PAGE 4 OF 2641

Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date

INDEPENDENTLY ACTIVATED.

19) REAR FACING OPTICAL INDICATORS WILL HAVE A MINIMUM OF SIX, (6) SIX

LED LIGHT HEAD MODULES.

20) DRIVER SIDE EXIT HOLE FOR HARNESS.

21) THE DRIVER SIDE OUTBOARD FORWARD FACING RED MODULE SHALL BE

PROGRAMMABLE TO INCLUDE STEADY # BURN MODE. THIS WILL BE PROGRAMMED AT

INSTALLATION IF CALIFORNIA TITLE XIII IS APPLICABLE.

22) THE FORWARD FACING MODULES FROM CENTER OUTWARD: TO THE

DRIVER SIDE WILL BE TAKE DOWN, FLASHING RED, FLASHING PROGRAMMABLE

RED. TO THE PASSENGER SIDE WILL BE TAKE DOWN, FLASHING BLUE, FLASHING

BLUE.

23) THE REAR FACING MODULES FROM CENTER OUTWARD: TO THE DRIVER SIDE

WILL BE FLASHING RED, FLASHING RED, FLASHING AMBER. TO THE PASSENGER

SIDE WILL BE FLASHING BLUE, FLASHING BLUE, FLASHING AMBER.

24) THE DRIVER SIDE CORNERS (FRONT AND REAR) WILL BE FLASHING RED.

25) THE PASSENGER SIDE CORNERS (FRONT AND REAR) WILL BE FLASHING BLUE.

26) LIGHT BAR MODULE PLACEMENT DESCRIPTION:

FRONT OF LIGHT BAR FROM DRIVER SIDE TO PASSENGER SIDE:

PROGRAMMABLE DRIVER RED, DRIVER RED, DRIVER CLEAR TAKE DOWN, PASSENGER

CLEAR TAKE DOWN, PASSENGER BLUE, PASSENGER BLUE

BACK OF LIGHT BAR FROM DRIVERS SIDE TO PASSENGER SIDE:

DRIVER AMBER, DRIVER RED, DRIVER RED

PASSENGER BLUE, PASSENGER BLUE, PASSENGER AMBER.

DRIVERS SIDE CORNER OF LIGHT BAR:

CORNER RED, LEFT ALLEY, CORNER RED.

PASSENGER SIDE CORNER OF LIGHT BAR:

CORNER BLUE, RIGHT ALLEY, CORNER BLUE.

27) LIGHT HEAD ACTIVATION SPECIFICATIONS AND WIRE COLORS ARE AS FOLLOWS:

WIRE #1 = GREEN/BLACK 18 AWG., WILL ACTIVATE ALL REAR FACING LIGHT

MODULES INCLUDING THE REAR CORNERS, PIN POSITION (V) OF MALE 23 PIN

QUICK DISCONNECT CONNECTOR.

WIRE #2 = RED/WHITE 18 AWG., WILL ACTIVATE ALL FORWARD FACING LIGHT

MODULES INCLUDING THE FRONT CORNERS, PIN POSITION (J) OF MALE 23 PIN

QUICK DISCONNECT CONNECTOR.

WIRE #3 = ORANGE/BLACK 18 AWG., WILL ACTIVATE THE LEFT ALLEY LIGHT

MODULE, PIN POSITION (S) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.

WIRE #4 = ORANGE 18 AWG., WILL ACTIVATE THE RIGHT ALLEY LIGHT MODULE,

PIN POSITION (U) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.

WIRE #5 = BLUE 18 AWG., WILL ACTIVATE BOTH TAKE DOWN LIGHT MODULES, PIN

POSITION (M) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.

WIRE #6 = RED/BLACK 18 AWG., THIS WILL ACTIVATE THE PROGRAMMABLE DRIVER

SIDE OUTBOARD LIGHT MODULE FOR STEADY BURN MODE ON CALIFORNIA TITLE XIII

COMPLIANT VEHICLES. THIS MODULE WILL BE PROGRAMMED AT INSTALLATION. IT

WILL BE REQUIRED TO BE FIELD PROGRAMMABLE, PIN POSITION (K) OF MALE 23

DJU6200008501 PAGE 5 OF 2641

Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date

PIN QUICK DISCONNECT CONNECTOR.

GROUND #1 = BLACK 18 AWG., PIN POSITION (D) OF MALE 23 PIN QUICK

DISCONNECT CONNECTOR.

GROUND #2 = BLACK 18 AWG., PIN POSITION (E) OF MALE 23 PIN QUICK

DISCONNECT CONNECTOR.

GROUND #3 = BLACK 18 AWG., PIN POSITION (F) OF MALE 23 PIN QUICK

DISCONNECT CONNECTOR.

GROUND #4 = BLACK 18 AWG., PIN POSITION (G) OF MALE 23 PIN QUICK

DISCONNECT CONNECTOR.

28) A 5-6 WATT, ½ AMP (MINIMUM) SOLAR PANEL WILL BE MOUNTED TO THE UPPER

SECTION OF THE LIGHT BAR, THE SOLAR PANEL MUST WORK WITH ALL BATTERIES,

HAVE HIGH PULSING DE-SULPHATION AT 22-28 KHZ, MAX DC VOLTAGE CHARGE OF

16.5 VOLTS AT DIRECT SUNLIGHT. MUST BE DESIGNED FOR RENEWAL AND MINIMUM

CHARGING OF BATTERIES, SOLAR PANEL CAN HAVE BETWEEN 80 AND 150 SQUARE

INCHES OF LIGHT COLLECTION AREA. THE SOLAR PANEL MUST INCLUDE THE SOLAR

PANEL REGULATOR. THE REGULATOR MUST HAVE A RED BLINKING LED THAT

DESIGNATES PROPER FUNCTION OF PANEL. ALL WIRING AND CONNECTORS MUST BE

INCLUDED AND BE INCORPORATED INTO THE LIGHT BAR WIRING HARNESS.

THE SOLAR PANEL WIRING FROM THE LIGHT BAR TO THE MALE 23 PIN QUICK

DISCONNECT PLUG WILL BE AS FOLLOWS:

RED = PIN POSITION (H) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.

BLACK = PIN POSITION (Z) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.

YELLOW = PIN POSITION (P) OF MALE 23 PIN QUICK DISCONNECT

CONNECTOR.

29) THE LEADS FROM THE SOLAR PANEL REGULATOR THAT CONNECT TO THE

VEHICLES BATTERY WILL BE (32) THIRTY TWO INCHES IN LENGTH WITH A PACKARD

DELPHI METRI PACK 150 SERIES SEALED TWO CAVITY FEMALE CONNECTOR THAT

HOUSES FEMALE TERMINAL SOCKETS (12) TWELVE INCHES FROM THE REGULATOR,

THE MALE 2 PIN CONNECTOR THAT HOUSES MALE TERMINAL PINS WILL HAVE THE

REMAINING (20) TWENTY INCHES OF RED/BLACK DUPLEX WIRE FOR CONNECTION TO

THE BATTERY TERMINALS.

TWO CAVITY CONNECTOR PIN OUTS AS FOLLOWS:

RED = PIN POSITION (A)

BLACK = PIN POSITION (B)

30) THE LEADS FROM THE SOLAR PANEL REGULATOR TO THE MALE THREE CAVITY

CONNECTOR THAT CONNECTS TO THE LIGHT BAR HARNESS WILL BE (18) EIGHTEEN

INCHES, THE CONNECTOR WILL BE A PACKARD DELPHI METRI PACK 150 SERIES

SEALED CONNECTOR THAT HOUSES THE MALE TERMINAL PINS.

THE THREE (3) CAVITY CONNECTOR PIN OUTS AS FOLLOWS:

RED = PIN POSITION (A)

BLACK = PIN POSITION (B)

YELLOW = PIN POSITION (C)

31) THE CABLE FROM THE LIGHT BAR EXIT HOLE TO THE ROOF TOP MOUNTED

FEMALE QUICK DISCONNECT BULKHEAD CONNECTOR WILL BE 26 INCHES LONG, IT

WILL TERMINATE INTO A MALE 23 PIN CONNECTOR THAT HOUSES MALE TERMINAL

PINS, IT WILL BE A SEALED CABLE INCORPORATING ALL WIRING FOR THE LIGHT

DJU6200008501 PAGE 6 OF 2641

Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date

MODULES AND THE SOLAR PANEL. THE CONNECTOR WILL BE A STRAIGHT PLUG THAT

WILL FIT INTO THE ROOF TOP MOUNTED BULKHEAD CONNECTOR WITH A TWIST TO

LOCK IN PLACE FEATURE. IT WILL ACCEPT 16-18 AWG AND THE 23 PINS WILL BE

DESIGNATED BY LETTERS OF THE ALPHABET FOR MATING TO THE PROPER SOCKETS

OF THE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR.

32) MUST INCLUDE ALL NECESSARY MOUNTING HARDWARE AND SEALS TO MOUNT

LIGHT BAR HARNESS THROUGH ROOF VIA THE ROOF TOP BULKHEAD CONNECTOR; THE

FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR THAT HOUSES THE FEMALE

SOCKET TERMINALS; THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD

CONNECTOR TO THE SIREN CONTROLLER ADAPTOR PLUG; THE WIRING FROM THE

FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR TO THE GROUND LUG RING

CONNECTOR AND THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD

CONNECTOR TO THE SOLAR PANEL REGULATOR ADAPTOR PLUG.

33) THE 23 SOCKET ROOF TOP MOUNTED BULKHEAD CONNECTOR IS A 90°, AERO-

DYNAMICALLY SHAPED PLUG. HEIGHT WILL BE NO MORE THAN 40 MM. AND WIDTH

WILL BE NO MORE THAN 75 MM. AND LENGTH WILL BE NO LONGER THAN 90 MM. IT

WILL HAVE A RUBBER GASKET FOR MOUNTING SEAL AND WILL HAVE A MINIMUM OF

FOUR SCREW MOUNTING POINTS FOR THROUGH ROOF MOUNTING. THE WIRE ACCESS

HOLE WILL BE 1 ¼ INCH. IT WILL ACCEPT FEMALE SOCKET TERMINALS AND THE

SOCKETS ARE CAPABLE OF ACCEPTING 16-18 AWG. THE QUICK DISCONNECT

RECEIVER OF THE CONNECTOR WILL RECEIVE THE MALE 23 PIN CONNECTOR. IT HAS

TWIST TO LOCK IN PLACE TABS FOR SECURE MATING TO THE MALE PLUG.

34) THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR TO

THE SIREN CONTROLLER ADAPTOR PLUG WILL BE (15) FIFTEEN FEET LONG. THE

SIREN CONTROLLER ADAPTOR PLUG WILL BE A PACKARD DELPHI METRI PACK 150

SERIES SEALED (6) SIX CAVITY CONNECTOR; IT WILL BE THE MALE END THAT

HOUSES THE MALE TERMINAL PINS.

THE SIX (6) CAVITY CONNECTOR PIN OUTS ARE AS FOLLOWS:

GREEN/BLACK = WIRE 1 =POSITION (A)

RED/WHITE = WIRE 2 = POSITION (B)

ORANGE/BLACK = WIRE 3 = POSITION (C)

ORANGE = WIRE 4 = POSITION (D)

BLUE = WIRE 5 =POSITION (E)

RED/BLACK = WIRE 6 =POSITION (F)

THE WIRE CONNECTIONS TO THE 23 SOCKET ROOF TOP MOUNTED BULKHEAD

CONNECTOR ARE AS FOLLOWS:

GREEN WITH BLACK = WIRE 1 =POSITION (V)

RED WITH WHITE = WIRE 2 = POSITION (J)

ORANGE WITH BLACK= WIRE 3 = POSITION (S)

ORANGE = WIRE 4 = POSITION (U)

BLUE = WIRE 5 =POSITION (M)

RED WITH BLACK = WIRE 6 =POSITION (K)

35) THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR TO

THE SOLAR PANEL ADAPTOR PLUG WILL BE (16) SIXTEEN FEET LONG. THE SOLAR

PANEL ADAPTOR PLUG WILL BE A PACKARD DELPHI METRI PACK 150 SERIES SEALED

(3) THREE CAVITY CONNECTOR. IT WILL BE THE FEMALE END THAT HOUSES THE

FEMALE TERMINAL SOCKETS.

DJU6200008501 PAGE 7 OF 2641

Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date

THE THREE (3) CAVITY FEMALE CONNECTOR PIN OUTS ARE AS FOLLOWS:

RED = PIN POSITION (A)

BLACK = PIN POSITION (B)

YELLOW = PIN POSITION (C)

THE WIRE CONNECTIONS TO THE 23 SOCKET ROOF TOP MOUNTED BULKHEAD

CONNECTOR ARE AS FOLLOWS:

RED = PIN POSITION (H)

BLACK = PIN POSITION (Z)

YELLOW = PIN POSITION (P)

36) THE GROUND WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD

CONNECTOR TO THE GROUND LUG RING TERMINAL WILL BE (17) SEVENTEEN FEET

LONG. THE (4) FOUR GROUND WIRES WILL TERMINATE INTO (1) ONE NON SHIELDED

RING CONNECTOR WITH A ¼ INCH EYELET. THE PIN POSITIONS OF THE GROUND

WIRES IN THE FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR ARE AS

FOLLOWS:

GROUND #1 = BLACK 18 AWG., PIN POSITION (D) OF FEMALE 23 SOCKET ROOF TOP

MOUNTED BULKHEAD CONNECTOR.

GROUND #2 = BLACK 18 AWG., PIN POSITION (E) OF FEMALE 23 SOCKET ROOF TOP

MOUNTED BULKHEAD CONNECTOR.

GROUND #3 = BLACK 18 AWG., PIN POSITION (F) OF FEMALE 23 SOCKET ROOF TOP

MOUNTED BULKHEAD CONNECTOR.

GROUND #4 = BLACK 18 AWG., PIN POSITION (G) OF FEMALE 23 SOCKET ROOF TOP

MOUNTED BULKHEAD CONNECTOR.

DJU6200008501 PAGE 8 OF 2641

Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date

00002 LMPCH108STD0001 100 EA 5000038103

LIGHTBAR,ALL,LED,STD,CH-SUBURBAN

THIS LIGHT BAR WILL FIT THE CHEVY SUBURBAN.

LENGTH: 54 INCHES, TOLERANCE: + OR - (2) TWO INCHES

INCLUDES STAINLESS STEEL GUTTER RAIL STYLE MOUNTS AND ACCOMPANYING

HARDWARE FOR ROOF TOP INSTALLATION. MUST INCLUDE INSTALLATION

INSTRUCTIONS AND

SIX (6) RIVETS

HEAD STYLE: Dome

RIVET MATERIAL: Stainless Steel

MANDREL MATERIAL: Stainless Steel

RIVET DIAMETER: 3/16 Inch

GRIP RANGE: 3/8 - 1/2 Inch

STANDARD LIGHT CONFIGURATION, LED, LIGHT BAR, W/5 WATT ½ AMP (MINIMUM)

SOLAR PANEL AND SOLAR PANEL REGULATOR W/LED INDICATOR, WITH 26 INCH

PIGTAIL TO ROOF TOP MOUNTED QUICK DISCONNECT BULKHEAD CONNECTOR, 23

POSITION ROOF TOP MOUNTED BULKHEAD CONNECTOR, AND ALL ACCOMPANYING

WIRING TO AND FROM ROOF TOP CONNECTOR AND SIREN CONTROLLER AND FROM ROOF

TOP CONNECTOR TO SOLAR PANEL REGULATOR.

1) MEETS ALL APPLICABLE SAE, FMVSS AND CALIFORNIA TITLE XIII STANDARDS

WHEN PROPERLY CONFIGURED.

2) ALL LED MODULES WILL BE CLEAR UNTIL ILLUMINATED AND WILL BE HIGH

INTENSITY LEDs.

3) FIVE YEAR WARRANTY MINIMUM.

4) LOW PROFILE MODULAR DESIGN.

5) CORROSION RESISTANT ALL ALUMINUM HOUSING WITH NO PLASTIC OR COMPOSITE

COVERS.

6) UV RESISTANT POLY CARBONATE LENS.

7) ABILITY TO INTEGRATE DIRECTIONAL INDICATORS FOR REAR FACING MODULES.

8) FULL 360° VISIBILITY.

9) MAINTENANCE FREE.

10) WILL OPERATE ON 12 VOLT NEGATIVE GROUND SYSTEM.

11) SOLID - STATE ELECTRONICS NOT EXCEEDING 12 AMPS AT FULL OPERATION.

12) ALL FORWARD AND REAR FACING MODULES WILL HAVE (6) LEDs MINIMUM PER

MODULE.

13) ALL CORNER MODULES WILL HAVE (12) LEDs MINIMUM PER MODULE.

14) TAKE DOWN MODULES WILL BE HIGH INTENSITY LEDs (CLEAR).

15) ALLEY MODULES WILL BE HIGH INTENSITY LEDs (CLEAR)

16) EACH CORNER WILL CONTAIN AT MINIMUM ONE 12 LED LIGHT HEAD MODULE.

17) FORWARD FACING OPTICAL INDICATORS WILL HAVE A MINIMUM OF FOUR, (6)

SIX LED LIGHT HEAD MODULES AND (2) TWO LED TAKE DOWN MODULES WITH A

MINIMUM OF (3) THREE HIGH INTENSITY LEDs.

18) TAKE DOWN LEDs WILL FLASH ALTERNATELY AND ACTIVATE WITH

FRONT LEDs. THIS FEATURE WILL BE OVERRIDDEN WHEN TAKE DOWNS ARE

DJU6200008501 PAGE 9 OF 2641

Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date

INDEPENDENTLY ACTIVATED.

19) REAR FACING OPTICAL INDICATORS WILL HAVE A MINIMUM OF SIX, (6) SIX

LED LIGHT HEAD MODULES.

20) DRIVER SIDE EXIT HOLE FOR HARNESS.

21) THE DRIVER SIDE OUTBOARD FORWARD FACING RED MODULE SHALL BE

PROGRAMMABLE TO INCLUDE STEADY # BURN MODE. THIS WILL BE PROGRAMMED AT

INSTALLATION IF CALIFORNIA TITLE XIII IS APPLICABLE.

22) THE FORWARD FACING MODULES FROM CENTER OUTWARD: TO THE

DRIVER SIDE WILL BE TAKE DOWN, FLASHING RED, FLASHING PROGRAMMABLE

RED. TO THE PASSENGER SIDE WILL BE TAKE DOWN, FLASHING BLUE, FLASHING

BLUE.

23) THE REAR FACING MODULES FROM CENTER OUTWARD: TO THE DRIVER SIDE

WILL BE FLASHING RED, FLASHING RED, FLASHING AMBER. TO THE PASSENGER

SIDE WILL BE FLASHING BLUE, FLASHING BLUE, FLASHING AMBER.

24) THE DRIVER SIDE CORNERS (FRONT AND REAR) WILL BE FLASHING RED.

25) THE PASSENGER SIDE CORNERS (FRONT AND REAR) WILL BE FLASHING BLUE.

26) LIGHT BAR MODULE PLACEMENT DESCRIPTION:

FRONT OF LIGHT BAR FROM DRIVER SIDE TO PASSENGER SIDE:

PROGRAMMABLE DRIVER RED, DRIVER RED, DRIVER CLEAR TAKE DOWN, PASSENGER

CLEAR TAKE DOWN, PASSENGER BLUE, PASSENGER BLUE

BACK OF LIGHT BAR FROM DRIVERS SIDE TO PASSENGER SIDE:

DRIVER AMBER, DRIVER RED, DRIVER RED

PASSENGER BLUE, PASSENGER BLUE, PASSENGER AMBER.

DRIVERS SIDE CORNER OF LIGHT BAR:

CORNER RED, LEFT ALLEY, CORNER RED.

PASSENGER SIDE CORNER OF LIGHT BAR:

CORNER BLUE, RIGHT ALLEY, CORNER BLUE.

27) LIGHT HEAD ACTIVATION SPECIFICATIONS AND WIRE COLORS ARE AS FOLLOWS:

WIRE #1 = GREEN/BLACK 18 AWG., WILL ACTIVATE ALL REAR FACING LIGHT

MODULES INCLUDING THE REAR CORNERS, PIN POSITION (V) OF MALE 23 PIN

QUICK DISCONNECT CONNECTOR.

WIRE #2 = RED/WHITE 18 AWG., WILL ACTIVATE ALL FORWARD FACING LIGHT

MODULES INCLUDING THE FRONT CORNERS, PIN POSITION (J) OF MALE 23 PIN

QUICK DISCONNECT CONNECTOR.

WIRE #3 = ORANGE/BLACK 18 AWG., WILL ACTIVATE THE LEFT ALLEY LIGHT

MODULE, PIN POSITION (S) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.

WIRE #4 = ORANGE 18 AWG., WILL ACTIVATE THE RIGHT ALLEY LIGHT MODULE,

PIN POSITION (U) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.

WIRE #5 = BLUE 18 AWG., WILL ACTIVATE BOTH TAKE DOWN LIGHT MODULES, PIN

POSITION (M) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.

WIRE #6 = RED/BLACK 18 AWG., THIS WILL ACTIVATE THE PROGRAMMABLE DRIVER

SIDE OUTBOARD LIGHT MODULE FOR STEADY BURN MODE ON CALIFORNIA TITLE XIII

DJU6200008501 PAGE 10 OF 2641

Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date

COMPLIANT VEHICLES. THIS MODULE WILL BE PROGRAMMED AT INSTALLATION. IT

WILL BE REQUIRED TO BE FIELD PROGRAMMABLE, PIN POSITION (K) OF MALE 23

PIN QUICK DISCONNECT CONNECTOR.

GROUND #1 = BLACK 18 AWG., PIN POSITION (D) OF MALE 23 PIN QUICK

DISCONNECT CONNECTOR.

GROUND #2 = BLACK 18 AWG., PIN POSITION (E) OF MALE 23 PIN QUICK

DISCONNECT CONNECTOR.

GROUND #3 = BLACK 18 AWG., PIN POSITION (F) OF MALE 23 PIN QUICK

DISCONNECT CONNECTOR.

GROUND #4 = BLACK 18 AWG., PIN POSITION (G) OF MALE 23 PIN QUICK

DISCONNECT CONNECTOR.

28) A 5-6 WATT, ½ AMP (MINIMUM) SOLAR PANEL WILL BE MOUNTED TO THE UPPER

SECTION OF THE LIGHT BAR, THE SOLAR PANEL MUST WORK WITH ALL BATTERIES,

HAVE HIGH PULSING DE-SULPHATION AT 22-28 KHZ, MAX DC VOLTAGE CHARGE OF

16.5 VOLTS AT DIRECT SUNLIGHT. MUST BE DESIGNED FOR RENEWAL AND MINIMUM

CHARGING OF BATTERIES, SOLAR PANEL CAN HAVE BETWEEN 80 AND 150 SQUARE

INCHES OF LIGHT COLLECTION AREA. THE SOLAR PANEL MUST INCLUDE THE SOLAR

PANEL REGULATOR. THE REGULATOR MUST HAVE A RED BLINKING LED THAT

DESIGNATES PROPER FUNCTION OF PANEL. ALL WIRING AND CONNECTORS MUST BE

INCLUDED AND BE INCORPORATED INTO THE LIGHT BAR WIRING HARNESS.

THE SOLAR PANEL WIRING FROM THE LIGHT BAR TO THE MALE 23 PIN QUICK

DISCONNECT PLUG WILL BE AS FOLLOWS:

RED = PIN POSITION (H) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.

BLACK = PIN POSITION (Z) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.

YELLOW = PIN POSITION (P) OF MALE 23 PIN QUICK DISCONNECT

CONNECTOR.

29) THE LEADS FROM THE SOLAR PANEL REGULATOR THAT CONNECT TO THE

VEHICLES BATTERY WILL BE (32) THIRTY TWO INCHES IN LENGTH WITH A PACKARD

DELPHI METRI PACK 150 SERIES SEALED TWO CAVITY FEMALE CONNECTOR THAT

HOUSES FEMALE TERMINAL SOCKETS (12) TWELVE INCHES FROM THE REGULATOR,

THE MALE 2 PIN CONNECTOR THAT HOUSES MALE TERMINAL PINS WILL HAVE THE

REMAINING (20) TWENTY INCHES OF RED/BLACK DUPLEX WIRE FOR CONNECTION TO

THE BATTERY TERMINALS.

TWO CAVITY CONNECTOR PIN OUTS AS FOLLOWS:

RED = PIN POSITION (A)

BLACK = PIN POSITION (B)

30) THE LEADS FROM THE SOLAR PANEL REGULATOR TO THE MALE THREE CAVITY

CONNECTOR THAT CONNECTS TO THE LIGHT BAR HARNESS WILL BE (18) EIGHTEEN

INCHES, THE CONNECTOR WILL BE A PACKARD DELPHI METRI PACK 150 SERIES

SEALED CONNECTOR THAT HOUSES THE MALE TERMINAL PINS.

THE THREE (3) CAVITY CONNECTOR PIN OUTS AS FOLLOWS:

RED = PIN POSITION (A)

BLACK = PIN POSITION (B)

YELLOW = PIN POSITION (C)

31) THE CABLE FROM THE LIGHT BAR EXIT HOLE TO THE ROOF TOP MOUNTED

DJU6200008501 PAGE 11 OF 2641

Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date

FEMALE QUICK DISCONNECT BULKHEAD CONNECTOR WILL BE 26 INCHES LONG, IT

WILL TERMINATE INTO A MALE 23 PIN CONNECTOR THAT HOUSES MALE TERMINAL

PINS, IT WILL BE A SEALED CABLE INCORPORATING ALL WIRING FOR THE LIGHT

MODULES AND THE SOLAR PANEL. THE CONNECTOR WILL BE A STRAIGHT PLUG THAT

WILL FIT INTO THE ROOF TOP MOUNTED BULKHEAD CONNECTOR WITH A TWIST TO

LOCK IN PLACE FEATURE. IT WILL ACCEPT 16-18 AWG AND THE 23 PINS WILL BE

DESIGNATED BY LETTERS OF THE ALPHABET FOR MATING TO THE PROPER SOCKETS

OF THE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR.

32) MUST INCLUDE ALL NECESSARY MOUNTING HARDWARE AND SEALS TO MOUNT

LIGHT BAR HARNESS THROUGH ROOF VIA THE ROOF TOP BULKHEAD CONNECTOR; THE

FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR THAT HOUSES THE FEMALE

SOCKET TERMINALS; THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD

CONNECTOR TO THE SIREN CONTROLLER ADAPTOR PLUG; THE WIRING FROM THE

FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR TO THE GROUND LUG RING

CONNECTOR AND THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD

CONNECTOR TO THE SOLAR PANEL REGULATOR ADAPTOR PLUG.

33) THE 23 SOCKET ROOF TOP MOUNTED BULKHEAD CONNECTOR IS A 90°, AERO-

DYNAMICALLY SHAPED PLUG. HEIGHT WILL BE NO MORE THAN 40 MM. AND WIDTH

WILL BE NO MORE THAN 75 MM. AND LENGTH WILL BE NO LONGER THAN 90 MM. IT

WILL HAVE A RUBBER GASKET FOR MOUNTING SEAL AND WILL HAVE A MINIMUM OF

FOUR SCREW MOUNTING POINTS FOR THROUGH ROOF MOUNTING. THE WIRE ACCESS

HOLE WILL BE 1 ¼ INCH. IT WILL ACCEPT FEMALE SOCKET TERMINALS AND THE

SOCKETS ARE CAPABLE OF ACCEPTING 16-18 AWG. THE QUICK DISCONNECT

RECEIVER OF THE CONNECTOR WILL RECEIVE THE MALE 23 PIN CONNECTOR. IT HAS

TWIST TO LOCK IN PLACE TABS FOR SECURE MATING TO THE MALE PLUG.

34) THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR TO

THE SIREN CONTROLLER ADAPTOR PLUG WILL BE (15) FIFTEEN FEET LONG. THE

SIREN CONTROLLER ADAPTOR PLUG WILL BE A PACKARD DELPHI METRI PACK 150

SERIES SEALED (6) SIX CAVITY CONNECTOR; IT WILL BE THE MALE END THAT

HOUSES THE MALE TERMINAL PINS.

THE SIX (6) CAVITY CONNECTOR PIN OUTS ARE AS FOLLOWS:

GREEN/BLACK = WIRE 1 =POSITION (A)

RED/WHITE = WIRE 2 = POSITION (B)

ORANGE/BLACK = WIRE 3 = POSITION (C)

ORANGE = WIRE 4 = POSITION (D)

BLUE = WIRE 5 =POSITION (E)

RED/BLACK = WIRE 6 =POSITION (F)

THE WIRE CONNECTIONS TO THE 23 SOCKET ROOF TOP MOUNTED BULKHEAD

CONNECTOR ARE AS FOLLOWS:

GREEN WITH BLACK = WIRE 1 =POSITION (V)

RED WITH WHITE = WIRE 2 = POSITION (J)

ORANGE WITH BLACK= WIRE 3 = POSITION (S)

ORANGE = WIRE 4 = POSITION (U)

BLUE = WIRE 5 =POSITION (M)

RED WITH BLACK = WIRE 6 =POSITION (K)

DJU6200008501 PAGE 12 OF 2641

Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date

35) THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR TO

THE SOLAR PANEL ADAPTOR PLUG WILL BE (16) SIXTEEN FEET LONG. THE SOLAR

PANEL ADAPTOR PLUG WILL BE A PACKARD DELPHI METRI PACK 150 SERIES SEALED

(3) THREE CAVITY CONNECTOR. IT WILL BE THE FEMALE END THAT HOUSES THE

FEMALE TERMINAL SOCKETS.

THE THREE (3) CAVITY FEMALE CONNECTOR PIN OUTS ARE AS FOLLOWS:

RED = PIN POSITION (A)

BLACK = PIN POSITION (B)

YELLOW = PIN POSITION (C)

THE WIRE CONNECTIONS TO THE 23 SOCKET ROOF TOP MOUNTED BULKHEAD

CONNECTOR ARE AS FOLLOWS:

RED = PIN POSITION (H)

BLACK = PIN POSITION (Z)

YELLOW = PIN POSITION (P)

36) THE GROUND WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD

CONNECTOR TO THE GROUND LUG RING TERMINAL WILL BE (17) SEVENTEEN FEET

LONG. THE (4) FOUR GROUND WIRES WILL TERMINATE INTO (1) ONE NON SHIELDED

RING CONNECTOR WITH A ¼ INCH EYELET. THE PIN POSITIONS OF THE GROUND

WIRES IN THE FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR ARE AS

FOLLOWS:

GROUND #1 = BLACK 18 AWG., PIN POSITION (D) OF FEMALE 23 SOCKET ROOF TOP

MOUNTED BULKHEAD CONNECTOR.

GROUND #2 = BLACK 18 AWG., PIN POSITION (E) OF FEMALE 23 SOCKET ROOF TOP

MOUNTED BULKHEAD CONNECTOR.

GROUND #3 = BLACK 18 AWG., PIN POSITION (F) OF FEMALE 23 SOCKET ROOF TOP

MOUNTED BULKHEAD CONNECTOR.

GROUND #4 = BLACK 18 AWG., PIN POSITION (G) OF FEMALE 23 SOCKET ROOF TOP

MOUNTED BULKHEAD CONNECTOR.

DJU6200008501 PAGE 13 OF 2641

Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date

00003 LMPCH10STD0001 20 EA 5000038103

LIGHTBAR,ALL,LED,STD,CH-IMPALA

THIS LIGHT BAR WILL FIT THE CHEVY IMPALA.

LENGTH: 48 INCHES, TOLERANCE: + OR - (2) TWO INCHES

INCLUDES STAINLESS STEEL GUTTER RAIL STYLE MOUNTS AND ACCOMPANYING

HARDWARE FOR ROOF TOP INSTALLATION. MUST INCLUDE INSTALLATION

INSTRUCTIONS AND

SIX (6) RIVETS

HEAD STYLE: Dome

RIVET MATERIAL: Stainless Steel

MANDREL MATERIAL: Stainless Steel

RIVET DIAMETER: 3/16 Inch

GRIP RANGE: 3/8 - 1/2 Inch

STANDARD LIGHT CONFIGURATION, LED, LIGHT BAR, W/5 WATT ½ AMP (MINIMUM)

SOLAR PANEL AND SOLAR PANEL REGULATOR W/LED INDICATOR, WITH 26 INCH

PIGTAIL TO ROOF TOP MOUNTED QUICK DISCONNECT BULKHEAD CONNECTOR, 23

POSITION ROOF TOP MOUNTED BULKHEAD CONNECTOR, AND ALL ACCOMPANYING

WIRING TO AND FROM ROOF TOP CONNECTOR AND SIREN CONTROLLER AND FROM ROOF

TOP CONNECTOR TO SOLAR PANEL REGULATOR.

1) MEETS ALL APPLICABLE SAE, FMVSS AND CALIFORNIA TITLE XIII STANDARDS

WHEN PROPERLY CONFIGURED.

2) ALL LED MODULES WILL BE CLEAR UNTIL ILLUMINATED AND WILL BE HIGH

INTENSITY LEDs.

3) FIVE YEAR WARRANTY MINIMUM.

4) LOW PROFILE MODULAR DESIGN.

5) CORROSION RESISTANT ALL ALUMINUM HOUSING WITH NO PLASTIC OR COMPOSITE

COVERS.

6) UV RESISTANT POLY CARBONATE LENS.

7) ABILITY TO INTEGRATE DIRECTIONAL INDICATORS FOR REAR FACING MODULES.

8) FULL 360° VISIBILITY.

9) MAINTENANCE FREE.

10) WILL OPERATE ON 12 VOLT NEGATIVE GROUND SYSTEM.

11) SOLID - STATE ELECTRONICS NOT EXCEEDING 12 AMPS AT FULL OPERATION.

12) ALL FORWARD AND REAR FACING MODULES WILL HAVE (6) LEDs MINIMUM PER

MODULE.

13) ALL CORNER MODULES WILL HAVE (12) LEDs MINIMUM PER MODULE.

14) TAKE DOWN MODULES WILL BE HIGH INTENSITY LEDs (CLEAR).

15) ALLEY MODULES WILL BE HIGH INTENSITY LEDs (CLEAR)

16) EACH CORNER WILL CONTAIN AT MINIMUM ONE 12 LED LIGHT HEAD MODULE.

17) FORWARD FACING OPTICAL INDICATORS WILL HAVE A MINIMUM OF FOUR, (6)

SIX LED LIGHT HEAD MODULES AND (2) TWO LED TAKE DOWN MODULES WITH A

MINIMUM OF (3) THREE HIGH INTENSITY LEDs.

18) TAKE DOWN LEDs WILL FLASH ALTERNATELY AND ACTIVATE WITH

FRONT LEDs. THIS FEATURE WILL BE OVERRIDDEN WHEN TAKE DOWNS ARE

DJU6200008501 PAGE 14 OF 2641

Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date

INDEPENDENTLY ACTIVATED.

19) REAR FACING OPTICAL INDICATORS WILL HAVE A MINIMUM OF SIX, (6) SIX

LED LIGHT HEAD MODULES.

20) DRIVER SIDE EXIT HOLE FOR HARNESS.

21) THE DRIVER SIDE OUTBOARD FORWARD FACING RED MODULE SHALL BE

PROGRAMMABLE TO INCLUDE STEADY # BURN MODE. THIS WILL BE PROGRAMMED AT

INSTALLATION IF CALIFORNIA TITLE XIII IS APPLICABLE.

22) THE FORWARD FACING MODULES FROM CENTER OUTWARD: TO THE

DRIVER SIDE WILL BE TAKE DOWN, FLASHING RED, FLASHING PROGRAMMABLE

RED. TO THE PASSENGER SIDE WILL BE TAKE DOWN, FLASHING BLUE, FLASHING

BLUE.

23) THE REAR FACING MODULES FROM CENTER OUTWARD: TO THE DRIVER SIDE

WILL BE FLASHING RED, FLASHING RED, FLASHING AMBER. TO THE PASSENGER

SIDE WILL BE FLASHING BLUE, FLASHING BLUE, FLASHING AMBER.

24) THE DRIVER SIDE CORNERS (FRONT AND REAR) WILL BE FLASHING RED.

25) THE PASSENGER SIDE CORNERS (FRONT AND REAR) WILL BE FLASHING BLUE.

26) LIGHT BAR MODULE PLACEMENT DESCRIPTION:

FRONT OF LIGHT BAR FROM DRIVER SIDE TO PASSENGER SIDE:

PROGRAMMABLE DRIVER RED, DRIVER RED, DRIVER CLEAR TAKE DOWN, PASSENGER

CLEAR TAKE DOWN, PASSENGER BLUE, PASSENGER BLUE

BACK OF LIGHT BAR FROM DRIVERS SIDE TO PASSENGER SIDE:

DRIVER AMBER, DRIVER RED, DRIVER RED

PASSENGER BLUE, PASSENGER BLUE, PASSENGER AMBER.

DRIVERS SIDE CORNER OF LIGHT BAR:

CORNER RED, LEFT ALLEY, CORNER RED.

PASSENGER SIDE CORNER OF LIGHT BAR:

CORNER BLUE, RIGHT ALLEY, CORNER BLUE.

27) LIGHT HEAD ACTIVATION SPECIFICATIONS AND WIRE COLORS ARE AS FOLLOWS:

WIRE #1 = GREEN/BLACK 18 AWG., WILL ACTIVATE ALL REAR FACING LIGHT

MODULES INCLUDING THE REAR CORNERS, PIN POSITION (V) OF MALE 23 PIN

QUICK DISCONNECT CONNECTOR.

WIRE #2 = RED/WHITE 18 AWG., WILL ACTIVATE ALL FORWARD FACING LIGHT

MODULES INCLUDING THE FRONT CORNERS, PIN POSITION (J) OF MALE 23 PIN

QUICK DISCONNECT CONNECTOR.

WIRE #3 = ORANGE/BLACK 18 AWG., WILL ACTIVATE THE LEFT ALLEY LIGHT

MODULE, PIN POSITION (S) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.

WIRE #4 = ORANGE 18 AWG., WILL ACTIVATE THE RIGHT ALLEY LIGHT MODULE,

PIN POSITION (U) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.

WIRE #5 = BLUE 18 AWG., WILL ACTIVATE BOTH TAKE DOWN LIGHT MODULES, PIN

POSITION (M) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.

WIRE #6 = RED/BLACK 18 AWG., THIS WILL ACTIVATE THE PROGRAMMABLE DRIVER

SIDE OUTBOARD LIGHT MODULE FOR STEADY BURN MODE ON CALIFORNIA TITLE XIII

DJU6200008501 PAGE 15 OF 2641

Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date

COMPLIANT VEHICLES. THIS MODULE WILL BE PROGRAMMED AT INSTALLATION. IT

WILL BE REQUIRED TO BE FIELD PROGRAMMABLE, PIN POSITION (K) OF MALE 23

PIN QUICK DISCONNECT CONNECTOR.

GROUND #1 = BLACK 18 AWG., PIN POSITION (D) OF MALE 23 PIN QUICK

DISCONNECT CONNECTOR.

GROUND #2 = BLACK 18 AWG., PIN POSITION (E) OF MALE 23 PIN QUICK

DISCONNECT CONNECTOR.

GROUND #3 = BLACK 18 AWG., PIN POSITION (F) OF MALE 23 PIN QUICK

DISCONNECT CONNECTOR.

GROUND #4 = BLACK 18 AWG., PIN POSITION (G) OF MALE 23 PIN QUICK

DISCONNECT CONNECTOR.

28) A 5-6 WATT, ½ AMP (MINIMUM) SOLAR PANEL WILL BE MOUNTED TO THE UPPER

SECTION OF THE LIGHT BAR, THE SOLAR PANEL MUST WORK WITH ALL BATTERIES,

HAVE HIGH PULSING DE-SULPHATION AT 22-28 KHZ, MAX DC VOLTAGE CHARGE OF

16.5 VOLTS AT DIRECT SUNLIGHT. MUST BE DESIGNED FOR RENEWAL AND MINIMUM

CHARGING OF BATTERIES, SOLAR PANEL CAN HAVE BETWEEN 80 AND 150 SQUARE

INCHES OF LIGHT COLLECTION AREA. THE SOLAR PANEL MUST INCLUDE THE SOLAR

PANEL REGULATOR. THE REGULATOR MUST HAVE A RED BLINKING LED THAT

DESIGNATES PROPER FUNCTION OF PANEL. ALL WIRING AND CONNECTORS MUST BE

INCLUDED AND BE INCORPORATED INTO THE LIGHT BAR WIRING HARNESS.

THE SOLAR PANEL WIRING FROM THE LIGHT BAR TO THE MALE 23 PIN QUICK

DISCONNECT PLUG WILL BE AS FOLLOWS:

RED = PIN POSITION (H) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.

BLACK = PIN POSITION (Z) OF MALE 23 PIN QUICK DISCONNECT CONNECTOR.

YELLOW = PIN POSITION (P) OF MALE 23 PIN QUICK DISCONNECT

CONNECTOR.

29) THE LEADS FROM THE SOLAR PANEL REGULATOR THAT CONNECT TO THE

VEHICLES BATTERY WILL BE (32) THIRTY TWO INCHES IN LENGTH WITH A PACKARD

DELPHI METRI PACK 150 SERIES SEALED TWO CAVITY FEMALE CONNECTOR THAT

HOUSES FEMALE TERMINAL SOCKETS (12) TWELVE INCHES FROM THE REGULATOR,

THE MALE 2 PIN CONNECTOR THAT HOUSES MALE TERMINAL PINS WILL HAVE THE

REMAINING (20) TWENTY INCHES OF RED/BLACK DUPLEX WIRE FOR CONNECTION TO

THE BATTERY TERMINALS.

TWO CAVITY CONNECTOR PIN OUTS AS FOLLOWS:

RED = PIN POSITION (A)

BLACK = PIN POSITION (B)

30) THE LEADS FROM THE SOLAR PANEL REGULATOR TO THE MALE THREE CAVITY

CONNECTOR THAT CONNECTS TO THE LIGHT BAR HARNESS WILL BE (18) EIGHTEEN

INCHES, THE CONNECTOR WILL BE A PACKARD DELPHI METRI PACK 150 SERIES

SEALED CONNECTOR THAT HOUSES THE MALE TERMINAL PINS.

THE THREE (3) CAVITY CONNECTOR PIN OUTS AS FOLLOWS:

RED = PIN POSITION (A)

BLACK = PIN POSITION (B)

YELLOW = PIN POSITION (C)

31) THE CABLE FROM THE LIGHT BAR EXIT HOLE TO THE ROOF TOP MOUNTED

DJU6200008501 PAGE 16 OF 2641

Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date

FEMALE QUICK DISCONNECT BULKHEAD CONNECTOR WILL BE 26 INCHES LONG, IT

WILL TERMINATE INTO A MALE 23 PIN CONNECTOR THAT HOUSES MALE TERMINAL

PINS, IT WILL BE A SEALED CABLE INCORPORATING ALL WIRING FOR THE LIGHT

MODULES AND THE SOLAR PANEL. THE CONNECTOR WILL BE A STRAIGHT PLUG THAT

WILL FIT INTO THE ROOF TOP MOUNTED BULKHEAD CONNECTOR WITH A TWIST TO

LOCK IN PLACE FEATURE. IT WILL ACCEPT 16-18 AWG AND THE 23 PINS WILL BE

DESIGNATED BY LETTERS OF THE ALPHABET FOR MATING TO THE PROPER SOCKETS

OF THE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR.

32) MUST INCLUDE ALL NECESSARY MOUNTING HARDWARE AND SEALS TO MOUNT

LIGHT BAR HARNESS THROUGH ROOF VIA THE ROOF TOP BULKHEAD CONNECTOR; THE

FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR THAT HOUSES THE FEMALE

SOCKET TERMINALS; THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD

CONNECTOR TO THE SIREN CONTROLLER ADAPTOR PLUG; THE WIRING FROM THE

FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR TO THE GROUND LUG RING

CONNECTOR AND THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD

CONNECTOR TO THE SOLAR PANEL REGULATOR ADAPTOR PLUG.

33) THE 23 SOCKET ROOF TOP MOUNTED BULKHEAD CONNECTOR IS A 90°, AERO-

DYNAMICALLY SHAPED PLUG. HEIGHT WILL BE NO MORE THAN 40 MM. AND WIDTH

WILL BE NO MORE THAN 75 MM. AND LENGTH WILL BE NO LONGER THAN 90 MM. IT

WILL HAVE A RUBBER GASKET FOR MOUNTING SEAL AND WILL HAVE A MINIMUM OF

FOUR SCREW MOUNTING POINTS FOR THROUGH ROOF MOUNTING. THE WIRE ACCESS

HOLE WILL BE 1 ¼ INCH. IT WILL ACCEPT FEMALE SOCKET TERMINALS AND THE

SOCKETS ARE CAPABLE OF ACCEPTING 16-18 AWG. THE QUICK DISCONNECT

RECEIVER OF THE CONNECTOR WILL RECEIVE THE MALE 23 PIN CONNECTOR. IT HAS

TWIST TO LOCK IN PLACE TABS FOR SECURE MATING TO THE MALE PLUG.

34) THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR TO

THE SIREN CONTROLLER ADAPTOR PLUG WILL BE (15) FIFTEEN FEET LONG. THE

SIREN CONTROLLER ADAPTOR PLUG WILL BE A PACKARD DELPHI METRI PACK 150

SERIES SEALED (6) SIX CAVITY CONNECTOR; IT WILL BE THE MALE END THAT

HOUSES THE MALE TERMINAL PINS.

THE SIX (6) CAVITY CONNECTOR PIN OUTS ARE AS FOLLOWS:

GREEN/BLACK = WIRE 1 =POSITION (A)

RED/WHITE = WIRE 2 = POSITION (B)

ORANGE/BLACK = WIRE 3 = POSITION (C)

ORANGE = WIRE 4 = POSITION (D)

BLUE = WIRE 5 =POSITION (E)

RED/BLACK = WIRE 6 =POSITION (F)

THE WIRE CONNECTIONS TO THE 23 SOCKET ROOF TOP MOUNTED BULKHEAD

CONNECTOR ARE AS FOLLOWS:

GREEN WITH BLACK = WIRE 1 =POSITION (V)

RED WITH WHITE = WIRE 2 = POSITION (J)

ORANGE WITH BLACK= WIRE 3 = POSITION (S)

ORANGE = WIRE 4 = POSITION (U)

BLUE = WIRE 5 =POSITION (M)

RED WITH BLACK = WIRE 6 =POSITION (K)

DJU6200008501 PAGE 17 OF 2641

Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date

35) THE WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR TO

THE SOLAR PANEL ADAPTOR PLUG WILL BE (16) SIXTEEN FEET LONG. THE SOLAR

PANEL ADAPTOR PLUG WILL BE A PACKARD DELPHI METRI PACK 150 SERIES SEALED

(3) THREE CAVITY CONNECTOR. IT WILL BE THE FEMALE END THAT HOUSES THE

FEMALE TERMINAL SOCKETS.

THE THREE (3) CAVITY FEMALE CONNECTOR PIN OUTS ARE AS FOLLOWS:

RED = PIN POSITION (A)

BLACK = PIN POSITION (B)

YELLOW = PIN POSITION (C)

THE WIRE CONNECTIONS TO THE 23 SOCKET ROOF TOP MOUNTED BULKHEAD

CONNECTOR ARE AS FOLLOWS:

RED = PIN POSITION (H)

BLACK = PIN POSITION (Z)

YELLOW = PIN POSITION (P)

36) THE GROUND WIRING FROM THE FEMALE 23 SOCKET ROOF TOP BULKHEAD

CONNECTOR TO THE GROUND LUG RING TERMINAL WILL BE (17) SEVENTEEN FEET

LONG. THE (4) FOUR GROUND WIRES WILL TERMINATE INTO (1) ONE NON SHIELDED

RING CONNECTOR WITH A ¼ INCH EYELET. THE PIN POSITIONS OF THE GROUND

WIRES IN THE FEMALE 23 SOCKET ROOF TOP BULKHEAD CONNECTOR ARE AS

FOLLOWS:

GROUND #1 = BLACK 18 AWG., PIN POSITION (D) OF FEMALE 23 SOCKET ROOF TOP

MOUNTED BULKHEAD CONNECTOR.

GROUND #2 = BLACK 18 AWG., PIN POSITION (E) OF FEMALE 23 SOCKET ROOF TOP

MOUNTED BULKHEAD CONNECTOR.

GROUND #3 = BLACK 18 AWG., PIN POSITION (F) OF FEMALE 23 SOCKET ROOF TOP

MOUNTED BULKHEAD CONNECTOR.

GROUND #4 = BLACK 18 AWG., PIN POSITION (G) OF FEMALE 23 SOCKET ROOF TOP

MOUNTED BULKHEAD CONNECTOR.

DJU6200008501 PAGE 18 OF 2641

Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date

00004 LMPCH17STD0001 20 EA 5000038103

49"LIGHTBAR,ALL-LED,STD,CHEVY-CAPRICE

MATERIAL:

THIS IS A ALL LED LIGHT BAR FOR THE CHEVY CAPRICE

SPECIFICATIONS:

Length: 49 Inches, Tolerance: + Or - (2) Two Inches

Includes Stainless Steel Gutter Rail Style Mounts And

Accompanying Hardware For Roof Top Installation And

SIX (6) RIVETS

HEAD STYLE: Dome

RIVET MATERIAL: Stainless Steel

MANDREL MATERIAL: Stainless Steel

RIVET DIAMETER: 3/16 Inch

GRIP RANGE: 3/8 - 1/2 Inch

Standard Light Configuration

All LED Light Bar

W/5 Watt ½ Amp (Minimum) Solar Panel And Solar Panel

Regulator W/Led Indicator

26 Inch Pigtail To Roof Top Mounted Quick Disconnect Bulkhead

Connector

23 Position Roof Top Mounted Bulkhead Connector

All Accompanying Wiring To And From Roof Top Connector

And Siren Controller And From Roof Top Connector To Solar

Panel Regulator.

1) Meets All Applicable SAE, FMVSS And California Title XIII

Standards When Properly Configured.

2) All LED Modules Will Be Clear Until Illuminated And Will Be

High Intensity Leds.

3) Five Year Warranty Minimum.

4) Low Profile Modular Design.

5) CORROSION RESISTANT ALL ALUMINUM HOUSING WITH NO PLASTIC OR COMPOSITE

COVERS.

6) UV Resistant Poly Carbonate Lens.

7) Ability To Integrate Directional Indicators For Rear

Facing Modules.

8) Full 360° Visibility.

9) Maintenance Free.

10) Will Operate On 12 Volt Negative Ground System.

11) Solid - State Electronics Not Exceeding 12 Amps At

Full Operation.

12) All Forward And Rear Facing Modules Will Have (6) LEDs

Minimum Per Module.

13) All Corner Modules Will Have (12) LEDs Minimum Per Module.

DJU6200008501 PAGE 19 OF 2641

Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date

14) Take Down Modules Will Be High Intensity LEDs (Clear).

15) Alley Modules Will Be High Intensity LEDs (Clear)

16) Each Corner Will Contain At Minimum One 12 LED Light

Head Module.

17) Forward Facing Optical Indicators Will Have A Minimum Of

Four, (6) Six LED Light Head Modules And (2) Two LED Take Down

Modules With A Minimum Of (3) Three High Intensity LEDs.

18) Take Down LEDs Will Flash Alternately And Activate With

Front LEDs. This Feature Will Be Overridden When Take Downs Are

Independently Activated.

19) Rear Facing Optical Indicators Will Have A Minimum Of Six,

(6) Six LED Light Head Modules.

20) Driver Side Exit Hole For Harness.

21) The Driver Side Outboard Forward Facing Red Module Shall Be

Programmable To Include Steady # Burn Mode. This Will Be

Programmed At Installation If California Title XIII Is Applicable.

22) The Forward Facing Modules From Center Outward: To The

Driver Side Will Be Take Down, Flashing Red, Flashing

Programmable Red. To The Passenger Side Will Be Take Down, Flashing Blue, Flashing Blue.

23) The Rear Facing Modules From Center Outward: To The Driver

Side Will Be Flashing Red, Flashing Red, Flashing Amber. To The

Passenger Side Will Be Flashing Blue, Flashing Blue, Flashing Amber.

24) The Driver Side Corners (Front And Rear) Will Be Flashing Red.

25) The Passenger Side Corners (Front And Rear) Will Be

Flashing Blue.

26) Light Bar Module Placement Description:

Front Of Light Bar From Driver Side To Passenger Side:

Programmable Driver Red, Driver Red, Driver Clear Take Down, Passenger Clear Take Down, Passenger Blue, Passenger Blue

Back Of Light Bar From Drivers Side To Passenger Side:

Driver Amber, Driver Red, Driver Red

Passenger Blue, Passenger Blue, Passenger Amber.

Drivers Side Corner Of Light Bar:

Corner Red, Left Alley, Corner Red.

Passenger Side Corner Of Light Bar:

Corner Blue, Right Alley, Corner Blue.

27) Light Head Activation Specifications And Wire Colors Are

As Follows:

Wire #1 = Green/Black 18 Awg., Will Activate All Rear Facing Light

Modules Including The Rear Corners, Pin Position (V) Of Male 23 Pin

Quick Disconnect Connector.

Wire #2 = Red/White 18 Awg., Will Activate All Forward Facing Light

DJU6200008501 PAGE 20 OF 2641

Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date

Modules Including The Front Corners, Pin Position (J) Of Male 23 Pin

Quick Disconnect Connector.

Wire #3 = Orange/Black 18 Awg., Will Activate The Left Alley Light

Module, Pin Position (S) Of Male 23 Pin Quick Disconnect Connector.

Wire #4 = Orange 18 Awg., Will Activate The Right Alley Light Module, Pin Position (U) Of Male 23 Pin Quick Disconnect Connector.

Wire #5 = Blue 18 Awg., Will Activate Both Take Down Light Modules, Pin Position (M) Of Male 23 Pin Quick Disconnect Connector.

Wire #6 = Red/Black 18 Awg., This Will Activate The Programmable

Driver Side Outboard Light Module For Steady Burn Mode On

California Title XIII Compliant Vehicles. This Module Will Be

Programmed At Installation. It Will Be Required To Be Field

Programmable, Pin Position (K) Of Male 23 Pin Quick Disconnect

Connector.

Ground #1 = Black 18 Awg., Pin Position (D) Of Male 23 Pin Quick

Disconnect Connector.

Ground #2 = Black 18 Awg., Pin Position (E) Of Male 23 Pin Quick

Disconnect Connector.

Ground #3 = Black 18 Awg., Pin Position (F) Of Male 23 Pin Quick

Disconnect Connector.

Ground #4 = Black 18 Awg., Pin Position (G) Of Male 23 Pin Quick

Disconnect Connector.

28) A 5-6 Watt, ½ Amp (Minimum) Solar Panel Will Be Mounted To

The Upper Section Of The Light Bar, The Solar Panel Must Work

With All Batteries, Have High Pulsing De-Sulphation At 22-28 Khz, Max Dc Voltage Charge Of 16.5 Volts At Direct Sunlight. Must Be

Designed For Renewal And Minimum Charging Of Batteries, Solar

Panel Can Have Between 80 And 150 Square Inches Of Light

Collection Area. The Solar Panel Must Include The Solar

Panel Regulator. The Regulator Must Have A Red Blinking Led That

Designates Proper Function Of Panel. All Wiring And Connectors

Must Be Included And Be Incorporated Into The Light Bar

Wiring Harness.

The Solar Panel Wiring From The Light Bar To The Male 23 Pin

Quick Disconnect Plug Will Be As Follows:

Red = Pin Position (H) Of Male 23 Pin Quick Disconnect Connector.

Black = Pin Position (Z) Of Male 23 Pin Quick Disconnect Connector.

Yellow = Pin Position (P) Of Male 23 Pin Quick Disconnect

Connector.

29) The Leads From The Solar Panel Regulator That Connect To The

Vehicles Battery Will Be (32) Thirty Two Inches In Length With A

Packard Delphi Metri Pack 150 Series Sealed Two Cavity Female

Connector That Houses Female Terminal Sockets (12) Twelve Inches

From The Regulator, The Male 2 Pin Connector That Houses Male

Terminal Pins Will Have The Remaining (20) Twenty Inches Of

Red/Black Duplex Wire For Connection To The Battery Terminals.

Two Cavity Connector Pin Outs As Follows:

DJU6200008501 PAGE 21 OF 2641

Item No. SUPPLIES OR SERVICES Quantity U/M UNIT PRICE AMOUNT IN US$ PR Number Del.Date

Red = Pin Position (A)

Black = Pin Position (B)

30) The Leads From The Solar Panel Regulator To The Male Three

Cavity Connector That Connects To The Light Bar Harness Will Be

(18) Eighteen Inches, The Connector Will Be A Packard Delphi

Metri Pack 150 Series Sealed Connector That Houses The Male

Terminal Pins.

The Three (3) Cavity Connector Pin Outs As Follows:

Red = Pin Position (A)

Black = Pin Position (B)

Yellow = Pin Position (C)

31) The Cable From The Light Bar Exit Hole To The Roof Top Mounted

Female Quick Disconnect Bulkhead Connector Will Be 26 Inches Long, It Will Terminate Into A Male 23 Pin Connector That Houses Male

Terminal Pins, It Will Be A Sealed Cable Incorporating All Wiring For

The Light Modules And The Solar Panel. The Connector Will Be A

Straight Plug That Will Fit Into The Roof Top Mounted Bulkhead

Connector With A Twist To Lock In Place Feature. It Will Accept

16-18 Awg And The 23 Pins Will Be Designated By Letters Of The

Alphabet For Mating To The Proper Sockets Of The 23 Socket Roof

Top Bulkhead Connector.

32) Must Include All Necessary Mounting Hardware And Seals To

Mount Light Bar Harness Through Roof Via The Roof Top Bulkhead

Connector; The Female 23 Socket Roof Top Bulkhead Connector

That Houses The Female Socket Terminals; The Wiring From The

Female 23 Socket Roof Top Bulkhead Connector To The Siren

Controller Adaptor Plug; The Wiring From The Female 23 Socket

Roof Top Bulkhead Connector To The Ground Lug Ring

Connector And The Wiring From The Female 23 Socket Roof Top

Bulkhead Connector To The Solar Panel Regulator Adaptor Plug.

33) The 23 Socket Roof Top Mounted Bulkhead Connector Is A 90°, Aero-Dynamically Shaped Plug. Height Will Be No More Than

40 mm. And Width Will Be No More Than 75 mm. And Length Will

Be No Longer Than 90 mm. It Will Have A Rubber Gasket For

Mounting Seal And Will Have A Minimum Of Four Screw

Mounting Points For Through Roof Mounting. The Wire Access

Hole Will Be 1 ¼ Inch. It Will Accept Female Socket Terminals And

The Sockets Are Capable Of Accepting 16-18 Awg.