Drawings.pdf
PDF 2 MB Posted
- Attached to
- Pasture Fencing Federal contract opportunity
- Solicitation number
- 12505B23R0011
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Site Visit Sign In Sheets.pdf | ||
| SF-30 Amend 01.pdf | ||
| Waterer Gate Detail.pdf | ||
| Past Performance Questionnaire.pdf | ||
| ARS-372.pdf | ||
| ARS-371.pdf | ||
| SF-1442.pdf | ||
| Statement of Work.pdf | ||
| Wage Determination - Heavy.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Location Coordinator:Contracting Officer Rep.:Contracting Officer:Engineering Project Manager:
Task
Order #:
Drawing Title:PROJECT TITLE:
FEU Project #:
Drawing Number:
Agricultural Research Service U.S. Department of Agriculture
NCAH
1920 Dayton Avenue Ames, Iowa 50010
Revision:
Client:
Sheet: Of
Designer:
Date:
Date:
UNITED STATES DEPARTMENT OF AGRICULTURE
AGRICULTURE RESEARCH SERVICE
NATIONAL CENTERS FOR ANIMAL HEALTH
WORK
AREAS
SITE
ENTRANCE
Order #:
Drawing Title:PROJECT TITLE:
FEU Project #:
Drawing Number:
Agricultural Research Service U.S. Department of Agriculture
NCAH
1920 Dayton Avenue Ames, Iowa 50010
Revision:
Client:
Sheet: Of
Designer:
Date:
2023 Campus Fencing Project
H1
N
LOT
B2
PASTURE
B2
B2 Pasture Fence Notes:
1) Red Line Indicates Pasture Fencing to be Replaced with new Pasture Fencing. The Length of new Pasture Fence is approximately 540.
2) Blue Line Indicates Pasture Fencing to be Replaced with Continuous Metal Fencing and Gate. The Length of new Continuous Metal Fence is approximately 110'.
3) Post are to be 5' above grade and 3' below grade set in concrete.
4) Corner post, gate hinge post, and the post located in approximately the center of the long runs are to be 8" post.
5) Install a removable section of Metal Fence to fit tight against Waterer that can be easily removed for maintenance.
H2
Order #:
Drawing Title:PROJECT TITLE:
FEU Project #:
Drawing Number:
Agricultural Research Service U.S. Department of Agriculture
NCAH
1920 Dayton Avenue Ames, Iowa 50010
Revision:
Client:
Sheet: Of
Designer:
Date:N
2023 Campus
Fencing Project
A7 Lot Fence Removal
Pasture Fence
Lot Fence
Order #:
Drawing Title:PROJECT TITLE:
FEU Project #:
Drawing Number:
Agricultural Research Service U.S. Department of Agriculture
NCAH
1920 Dayton Avenue Ames, Iowa 50010
Revision:
Client:
Sheet: Of
Designer:
Date:N
2023 Campus Fencing
Project
A7 Lot Fence Install
A7 Lot Fence Notes:
1) Install approximately 590 linear feet of new 5' high fence, five 4' gates, one 12' gate, and two 16' gates.
2) Post are to be 5' above grade and 3' below grade set in concrete.
3) Corner post, gate hinge post, and post in center of long run on east side are to be 8" post.
4) Install 6" Diagonal bracing on corner post and post in center of long run on east side of lot.
5) 12' and 16' Gates hinged on west end.
6) Reconnect existing pasture fence to new 8" corner post.
7) Contractor responsible for locating all underground utilities before installing new fence in new locations.
4' Gate 12' Gate 16' Gate Fencing
Order #:
Drawing Title:PROJECT TITLE:
FEU Project #:
Drawing Number:
Agricultural Research Service U.S. Department of Agriculture
NCAH
1920 Dayton Avenue Ames, Iowa 50010
Revision:
Client:
Sheet: Of
Designer:
Order #:
Drawing Title:PROJECT TITLE:
FEU Project #:
Drawing Number:
Agricultural Research Service U.S. Department of Agriculture
NCAH
1920 Dayton Avenue Ames, Iowa 50010
Revision:
Client:
Sheet: Of
Designer:
File details come from the government source that posted it. Updated .