ELECTRICAL LEGEND AND GENERAL
ELECTRICAL INTAKE STRUCTURE - FLOOR PLANS DEMOLITION
ELECTRICAL DETAILS SHEET II
DESIGN FILESHEET NO.
G-001
INDEX TO DRAWINGS
SHEET TITLE
E-001
E-101
E-501
E-502
HOU-BR-135_G-001.DWG COVER SHEET AND INDEX
US Army Corps of Engineers
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
New England District
SIGNATURES AFFIXED BELOW INDICATE OFFICIAL RECOMMENDATION AND APPROVAL
OF ALL DRAWINGS IN THIS SET AS INDEXED ON THIS SHEET
APPROVED FOR TECHNICAL ADEQUACY BY:
TECHNICAL LEAD ENGINEER DATE
DATE
DATE
DATE
DATE
APPROVED BY:
APPROVAL RECOMMENDED BY:
CHIEF, ENGINEERING DIVISION
This project was designed by the U.S. Army Corps of Engineers. The initials or signatures and registration designations of individuals appear on these project documents, within the scope of their employment as required by ER 1110-1-8152.
REVIEWED BY:
CHIEF, GEOTECHNICAL/WATER RESOURCES BRANCH
REVIEWED BY:
CHIEF, DESIGN BRANCH
CHIEF, GEO-ENVIRONMENTAL ENGINEERING BRANCH
LIGHTNING PROTECTION REPLACEMENT
BLACK ROCK LAKE
THOMASTON, CONNECTICUT
JAN 2023
G-001
C O
V E
R
S
H E
E T
A
N D
I
D E
X
J
C
L I N
E
J
C
L I N
E
J
N
E W
T O
N
J
N
E W
M A
N
A N
S I
D
N T
S
J A
N
US Army Corps of Engineers
U S
A
R M
Y
C
O R
P S
O
F
E
N G
I N
E E
R S
N E
W
E
N G
L A
S
T R
I C
T
V
I R
G I N
R
A
D
C O
N C
O R
D
M
A
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
S C
A L E
S
H E
E T
D R
A W
I N
G
C
O D
E
C O
N T
R A
C
S O
L I C
I T
A T
I O
N
N
O
I S
S U
E
D
A T
E
O F
SHEET ID
M A
R K
D E
S C
R I P
T I O
N D
A T
E
L I G
H T
N I N
G
P
R O
T E
C T
I O
N
R
E P
L A
C E
M E
N T
B L A
K
C
K
L A
K E
T H
O M
A S
T O
N
C
O N
N E
C T
I C
U T
H O
U B
R
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
W W
J Q
ELECTRICAL INTAKE STRUCTURE - FLOOR PLANS NEW WORKED101
ELECTRICAL DETAILS SHEET I
HOU-BR-135_E-001.DWG
HOU-BR-135_ED101.DWG
HOU-BR-135_E-101.DWG
HOU-BR-135_E-501.DWG
HOU-BR-135_E-502.DWG
PROJECT
LOCATION
PROJECT
LOCATION
MASSACHUSETTS
N E
W
Y
O R
K
WATERBURY
THOMASTON
HARTFORD
SPRINGFIELD
CONNECTICUT
C
O
N
N
E
C
T
I
C
U
V
E
R
NOT TO SCALE NOT TO SCALE
VICINITY MAPLOCATION PLAN
BRANCH ROAD
WATERTOWN ROAD
(ROUTE 6)
BLACK ROCK
STATE PARK
THOMASTON, CT
THOMASTON ROAD
(ROUTE 6)
ELECTRICAL DISTRIBUTION PLANS ELEVATION AND DETAILS
DRAWING NUMBERSHEET NO.
61A
INDEX TO REFERENCE DRAWINGS
SHEET TITLE
HOU-12 OUTLET WORKS - INTAKE TOWER MECHANICAL EQUPMENT PLAN, SECTIONS AND DETAILS
HOU-12
40A HOU-12 OUTLET WORKS - INTAKE TOWER ELECTRICAL PLANS AND DIAGRAM
46 HOU-12 OUTLET WORKS - CONDUIT PLAN, PROFILE & SECTIONS NO. 1
7 HOU-12 DAM EMBANKMENT - SECTIONS NO. 1
W912WJ23Q0029
James.M.Newman Text Box
JMN
E6CD9LAJ
Text Box N/A
E6CD9LAJ
Text Box N/A
E6CD9LAJ
Text Box 1/18/2023
E6CD9LAJ
Text Box 1/24/2023
EQUIPMENT LEGEND
208Y/120 VOLT, 3Ø, 4 WIRE PANEL
480Y/277 VOLT, 3Ø, 4 WIRE PANEL
XL
XD
XN
XR
XM
RESPONSIBLE FOR MAINTAINING CIRCUITRY TO DEVICES
TO POWER SOURCE AND LABEL BREAKER IN
PANELBOARD AS SPARE. CONTRACTOR SHALL BE
CONDUIT AS REQUIRED SO AS TO PROVIDE A
COMPLETE OPERATIONAL INSTALLATION.
TO BE REMOVED. CUT BACK AND MAKE SAFE ALL
ASSOCIATED BRANCH CIRCUIT WIRING CONDUIT BACK
EQUIPMENT TO BE REMOVED AND REPLACED WITH NEW.
"XL" ADJACENT TO EQUIPMENT DENOTES RELOCATED
EXISTING AT NEW LOCATION
UNAFFECTED BY DEMOLITION.
"XD" ADJACENT TO EQUIPMENT DENOTES EXISTING
"XR" ADJACENT TO EQUIPMENT DENOTES EXISTING
"XN" ADJACENT TO EQUIPMENT DENOTES EXISTING
"XM" ADJACENT TO EQUIPMENT DENOTES EXISTING
SYMBOLS OUT OF FUNCTION DENOTES EXISTING
TO BE RELOCATED AS SHOWN. CUT BACK AND/OR
EXTEND EXISTING BRANCH CIRCUIT WIRING AND
EQUIPMENT TO REMAIN.
EXISTING EQUIPMENT LEGEND BUILDING GROUNDING GRID LEGEND
BOLTED CONNECTION
EXOTHERMICALLY WELDED CONNECTION
GROUND ROD
GROUNDING CABLE
AMPERES
AMERICANS WITH DISABILITIES ACT
AMPERE INTERRUPTING CAPACITY
AUTOMATIC TRANSFER SWITCH
ALUMINUM
INSTITUTE
ARCHITECT
AMERICAN NATIONAL STANDARDS
AUTHORITY HAVING JURISDICTION
ABOVE FINISH GRADE
AIR HANDLING UNIT
ABOVE FINISH FLOOR
AMERICAN WIRE GAUGE
BELOW FINISH GRADE
AUTOMATIC TEMPERATURE CONTROL
CONDUIT
CIRCUIT
COLUMN
CONTROL POWER TRANSFORMER
CIRCUIT BREAKER
CENTERLINE
CATALOG
CURRENT LIMITING FUSE
BUILDING
DIRECT DIGITAL CONTROL
COPPER
DRAWING
CURRENT TRANSFORMER
FAN COIL UNIT
ELECTRICAL CONTRACTOR
EXHAUST FAN
EMERGENCY
FIRE ALARM
ELECTRICAL METALLIC TUBING
ELECTRIC WATER COOLER
EMERGENCY POWER OFF
GROUND FAULT INTERRUPTER
GROUND OR GROUNDING
FLEXIBLE METAL CONDUIT
FULL LOAD AMPERES
ISOLATED GROUND
HAND, OFF, AUTOMATIC SWITCH
INTERLOCK
INSTITUTE OF ELECTRICAL AND
THOUSAND CIRCULAR MILS
ELECTRONIC ENGINEERS
INTERMEDIATE METAL CONDUIT
GALVANIZED RIGID METALLIC CONDUIT
CERTIFIED BALLAST MANUFACTURERS
HOA
IG
IEEE
IMC
INT
kcmil
FLA
FT
FMC
GFI
GRMC
GND,G
FEET
EM
EPO
EMT
F
FCU
FA
EWC
FUSE
DDL
CU
CT
DWG
EC
EF
CB
CKT
CBM
CPT
CLF
COL
CL
BFG
ATC
AWG
CAT
C
BLDG
AHU
AIC
AL
ATS
ARCH
ANSI
A
ADA
AFG
AFF
AHJ
PT POTENTIAL TRANSFORMER
PHASE
QUANTITY
REQUIRED
ROOF TOP UNIT
TELEPHONE
SYMMETRICAL
POLYVINYL CHLORIDE
RIGID METAL CONDUIT
ROOT MEAN SQUARED
RIGID NON-METALLIC CONDUIT
BREAKER
UNIT HEATER
TRANSFORMER
WEATHERPROOF
WATER HEATER
UNLESS OTHERWISE NOTED
UNDERGROUND OR UNDERGRADE
UNDERWRITERS LABORATORIES
UNINTERRUPTABLE POWER SUPPLY
THERMAL MAGNETIC CIRCUITTMCB
WH
XFMR
WP
W
V
DELTA
WYE
WIRE
VOLT
UG
UL
UPS
UH
U.O.N.
SP
RTU
RNMC
SW
TEL
SYM
SWITCH
SPARE
PWR
QTY
PVC
RMC
RMS
REQ'D
POWER
KILOWATTS
CONDUIT
LIGHTING
MISCELLANEOUS
MAIN LUGS ONLY
KILOVOLT AMPERES
NORMALLY CLOSED
METAL CLAD CABLE
MAIN CIRCUIT BREAKER
MOTOR CONTROL CENTER
MOTOR CIRCUIT PROTECTOR
LIQUIDTIGHT FLEXIBLE METAL
ASSOCIATION
NOT TO SCALE
PUSHBUTTON
NOT IN CONTRACT
NATIONAL ELECTRICAL
NATIONAL ELECTRIC CODE
MANUFACTURES ASSOCIATION
NATIONAL FIRE PROTECTION
PROVIDED UNDER OTHER SECTIONS
NORMALLY OPEN OR NUMBER
NO
NTS
POS
PNL
P
PB
PANEL
POLE
NEC
NEMA
N.I.C.
NFPA
MC
MCB
MCC
MCP
MLO
NC
MISC
kW kVA
LTG
LFMC
GENERAL ABBREVIATIONS
DOWN CONDUCTOR WITH GROUND ROD
AIR TERMINAL - 36 INCHES LONG
BOLTED BONDING CONNECTION
LIGHTNING PROTECTION CABLE
EXOTHERMIC BONDING CONNECTION
LP
CABINET UNIT HEATERCUH
IN EXISTING LOCATION.
TO BE REMOVED, STORED, CLEANED AND REINSTALLED
"XS" ADJACENT TO EQUIPMENT DENOTES EXISTING
XS
LIGHTNING PROTECTION LEGEND
G
Ø
Y
BUILDING SYSTEM GROUND BUS
HPF
HIGH POWER FACTOR
GROUND ROD INSPECTION PIT
20A, 125V, 2P, 3W DUPLEX RECEPTACLE
"WP" - WEATHERPROOF WHILE-IN-USE COVER
"GFCI" - GROUND FAULT CIRCUIT INTERRUPTER
WP
GFCI
SPD SURGE PROTECTIVE DEVICE
PC PHOTOCELL
CB CONTROL BOX - ELECTRIC ROOF HATCH
HOMERUN TO PANELBOARD. "B" INDICATES PANEL, "2"
INDICATES CIRCUIT NUMBER FOR REFERENCE, ( 20A-1P,
UNLESS NOTED OTHERWISE.) PROVIDE 2-12AWG, 1-12AWG
GND IN CONDUIT AS SPECIFIED ON THE FLOOR PLANS
B-2
EXISTING CONDUIT EMBEDDED IN CONCRETE
E-001
E L
E C
T R
I C
A L
L E
G E
N D
J C
L I N
E
J C
L I N
E
J
N
E W
T O
N
J
N
E W
M A
N
A N
S I
D
N T
S
J A
N
US Army Corps of Engineers
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
N E
W
E
N G
L A
S
T R
I C
T
V
I R
G I N
A
D
C O
N C
O R
D
M
A
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
S C
A L E
S
H E
E T
D R
A W
I N
G
C
O D
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
I S
S U
E
D
A T
E
O F
SHEET ID
M A
R K
D E
S C
R I P
T I O
N D
A T
E
L I G
H T
N I N
G
P
R O
T E
C T
I O
N
R
E P
L A
C E
M E
N T
B L A
C
K
L A
K E
T H
O M
A S
T O
N
C
O N
N E
C T
I C
U T
H O
U B
R
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
W W
J Q
James.M.Newman
JMN
L
D D
E R
EXISTING
ANTENNA
TO REMAIN
EXISTING
RAIN GAUGE
TO REMAIN
MC
MCMC
MC
MC
M C
M C
M C
M C
M C
M C
M
C
M C
8 5
EXISTING
GENERATOR
EXHAUST
PIPE TO
REMAIN
EXISTING STAINLESS
STEEL CHIMNEY CAP
TO REMAIN
(TYPICAL)
APPROXIMATE
EXTENT OF GATE
HOUSE ROOF
DISCONNECT AND REMOVE ALL AIR TERMINALS (TYP. 6).
REMOVE ALL ASSOCIATED MOUNTING BRACKETS AND
DEVICES ALONG WITH ADHESIVE AND ALL OTHER
ATTACHMENT METHODS (TYPICAL). AT PENETRATIONS
MADE IN THE EPDM ROOF, MADE ACCESSIBLE DUE TO THE
REMOVAL OF DEVICES, APPLY WATERBLOCK AND EPDM
PATCHING AND FLASHING MATERIALS FOR WATER TIGHT
SEAL. CLEAN AND PREP ROOF SURFACE AS
RECOMMENDED BY MEMBRANE FLASHING AND
WATERBLOCK MANUFACTURER PRIOR TO APPLICATION.
DISCONNECT AND REMOVE MAIN CONDUCTOR "MC" OF
LIGHTNING PROTECTION SYSTEM IN ITS ENTIRETY
(TYPICAL).
DISCONNECT AND REMOVE ALL BONDING CONDUCTORS
AND BONDS TO ROOF TOP EQUIPMENT TO INCLUDE, BUT
NOT LIMITED TO, THE ROOF HATCH, THE ANTENNA, THE
RAIN GAUGE AND THE GUARD RAILING.
EXISTING GROUND ROD TO BE DEMOLISHED.
DISCONNECT AND REMOVE EXISTING DOWN CONDUCTOR
IN ITS ENTIRETY, INCLUDING THE PVC CONDUITS, CLAMPS,
AND SUPPORTS. DISCONNECT AND REMOVE EXISTING
GROUND LOOP CONDUCTOR IN ITS ENTIRETY TO THE
GROUND ROD. COMPLETELY FILL HOLES AND
DEPRESSIONS, LEFT AS A RESULT OF REMOVALS IN
EXISTING MASONRY WALLS WITH AN APPROVED MASONRY
PATCHING MATERIAL, APPLIED IN ACCORDANCE WITH THE
MANUFACTURER'S PRINTED INSTRUCTIONS.
DISCONNECT AND REMOVE EXISTING GREEN GROUND
CONDUCTOR AND CLAMPS AT THIS LOCATION. GREEN
GROUND CONDUCTOR IS NO LONGER IN USE.
CONTRACTOR SHALL REMOVE AND STOCKPILE EXISTING
ROCK PROTECTION & UNDERLYING GRAVEL MATERIALS
SEPARATELY DURING CONSTRUCTION. REFER TO
SPECIFICATIONS FOR FURTHER DETAILS.
EXISTING SHEET METAL RAIN COLLAR ON ALL VERTICAL
RAILING POSTS TO REMAIN.
EXISTING GUARD RAILING.
1. FOR LEGEND AND GENERAL NOTES REFER TO E-001.
2. FOR NEW WORK REFER TO E-101.
3. REFER TO RECORD DRAWINGS AND PHOTOS ATTACHED TO
SPECIFICATION FOR ADDITIONAL INFORMATION.
ED101
E L
E C
T R
I C
A L
I N
T A
R
U C
T U
R E
F L
O O
R
P
L A
E M
O L
I T
I O
N
J C
L I N
E
J C
L I N
E
J
N
E W
T O
N
J N
E W
M A
N
A N
S I
D
J A
N
US Army Corps of Engineers
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
N E
W
E
N G
L A
S
T R
I C
T
V
I R
G I N
A
D
C O
N C
O R
D
M
A
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
S C
A L E
S
H E
E T
D R
A W
I N
G
C
O D
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
I S
S U
E
D
A T
E
O F
SHEET ID
M A
R K
D E
S C
R I P
T I O
N D
A T
E
L I G
H T
N I N
G
P
R O
T E
C T
I O
N
R
E P
L A
C E
M E
N T
B L A
C
K
L A
K E
T H
O M
A S
T O
N
C
O N
N E
C T
I C
U T
H O
U B
R
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
W W
J Q
SCALE: 1/4"=1'-0"
ROOF PLAN - DEMOLITION
H9
DETAIL H9 KEYNOTES
GENERAL NOTES
NOTE: ROOF ELEVATION IS APPROXIMATELY EL. 565 NGVD29; GROUND ELEVATION IS
APPROXIMATELY EL. 450 NGVD29
0 4' 8'2'
James.M.Newman
E6EDDJEN
E-501
L
E C
T R
I C
A L
D E
T A
I L
S
S
H E
J C
L I N
E
J C
L I N
E
J
N
E W
T O
N
J
N
E W
M A
N
A N
S I
D
N T
S
J A
N
US Army Corps of Engineers
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
N E
W
E
N G
L A
S
T R
I C
T
V
I R
G I N
A
D
C O
N C
O R
D
M
A
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
S C
A L E
S
H E
E T
D R
A W
I N
G
C
O D
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
I S
S U
E
D
A T
E
O F
SHEET ID
M A
R K
D E
S C
R I P
T I O
N D
A T
E
L I G
H T
N I N
G
P
R O
T E
C T
I O
N
R
E P
L A
C E
M E
N T
B L A
C
K
L A
K E
T H
O M
A S
T O
N
C
O N
N E
C T
I C
U T
H O
U B
R
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
W W
J Q
CLAMP
STAND-OFF POINT
HOLDERS
ALUMINUM
AIR TERMINAL
(CLASS 1)
10" MIN.
CAST IRON VALVE
BOX OR REINFORCED
CONCRETE PIPE WITH
FLARED END.
PROVIDE WITH CAST
IRON GRATED COVER
EXOTHERMIC
WELD
FILL WITH SAND
TO LEVEL SHOWN
GRADE
4" MAXIMUM
6"
12" I.D. MINIMUM
COPPER-CLAD STEEL
3/4" x 10' GROUND ROD
(10' MIN. EARTH
PENETRATION)
DOWN
CONDUCTOR
CABLE
SPLICER
BONDING
CONDUCTOR
BOND PLATE
MECHANICAL
EQUIPMENT
METAL
PLUMBING
VENT PIPE
NOTE:
PROVIDE PIPE MOUNTED AIR TERMINAL FOR PVC PIPE
ADJUSTABLE PIPE BONDING
STRAP
CONCEALED BELOW ROOF,
EXCEPT ON FLAT ROOF
ALUMINUM ROOF
CONDUCTOR (CLASS
1)
AIR TERMINAL
FLAT SURFACE
BASE
LIGHTNING
CONDUCTOR
CABLE
FASTENER
NOTE:
1. ALL COMPONENTS SUCH AS, BUT NOT LIMITED TO AIR TERMINAL BASE
PLATES, CABLE FASTENERS, BONDING PLATES ETC. THAT REQUIRE
PHYSICAL ATTACHMENT TO THE ROOFING SYSTEM SHALL BE BY
ADHESIVE MEANS PER INDUSTRY STANDARD. SCREWS, BOLTS, NAILS ETC.
ARE UNACCEPTABLE AS MEANS FOR ATTACHMENT FOR ALL COMPONENTS
OF THE LPS.
FLANGE
BONDING PLATE
BONDING PLATE BONDING LUG
HEAVY DUTY
BONDING LUG
BONDING PLATE
UL
U
L
3/4" x 10'
GROUND ROD
EXOTHERMIC WELD
CONNECTION
#1/0 AWG BARE
COPPER (STRANDED)
DOWN CONDUCTOR
1" CONDUIT
NOTE:
1. ALL COMPONENTS SUCH AS, BUT NOT LIMITED TO AIR TERMINAL BASE
PLATES, CABLE FASTENERS, BONDING PLATES ETC. THAT REQUIRE
PHYSICAL ATTACHMENT TO THE ROOFING SYSTEM SHALL BE BY
ADHESIVE MEANS PER INDUSTRY STANDARD. SCREWS, BOLTS, NAILS
ETC. ARE UNACCEPTABLE AS MEANS FOR ATTACHMENT FOR ALL
COMPONENTS OF THE LPS.
BI-METAL
CONNECTOR
BONDING
CONNECTOR
PARALLEL
CONNECTOR
PARALLEL
CONNECTOR
CROSS RUN
CONNECTOR
EXOTHERMIC WELD
"X" CONNECTION
GROUND ROD
EXOTHERMIC WELD
"T" CONNECTION TO
GROUND ROD
EXOTHERMIC WELD
END CONNECTION
VERTICAL PLATE
EXOTHERMIC WELD
"T" CONNECTION
SCALE: N.T.S.
BONDING CONNECTION DETAIL
K1
(SYMBOL )
SCALE: N.T.S.
AIR TERMINAL (SYMBOL )
K6
SCALE: N.T.S.
BONDING LUGS & PLATES DETAIL
K11
SCALE: N.T.S.
CABLE CONNECTIONS DETAIL
K16
SCALE: N.T.S.
GROUND ROD DETAIL
E5
SCALE: N.T.S.
VENT PIPE BONDING
E1
A11
SCALE: N.T.S.
DOWN CONDUCTOR ROUTING
A16
(SYMBOL )
NOTE:
1. SUPPORT AIR TERMINALS MORE THAN 24 INCHES IN LENGTH BY SUITABLE
BRACE PER INDUSTRY STANDARD. AIR TERMINAL SHALL BE SUPPORTED
AT NOT LESS THAN ON-HALF THE HEIGHT OF THE TERMINAL.
2. ALL COMPONENTS SUCH AS, BUT NOT LIMITED TO AIR TERMINAL BASE
PLATES, CABLE FASTENERS, BONDING PLATES ETC. THAT REQUIRE
PHYSICAL ATTACHMENT TO THE ROOFING SYSTEM SHALL BE BY
ADHESIVE MEANS PER INDUSTRY STANDARD. SCREWS, BOLTS, NAILS ETC
ARE UNACCEPTABLE AS MEANS FOR ATTACHMENT FOR ALL COMPONENTS
OF THE LPS.
EXOTHERMIC WELD CONNECTION
BELOW GRADE
SCALE: N.T.S.
LIGHTNING
CONDUCTOR
THRU ROOF
CONNECTOR
COORDINATE
LENGTH WITH
ACTUAL WALL
CONSTRUCTION AT
EACH LOCATION
LIGHTNING
CONDUCTOR
BONDING CABLE
BONDING LUG
ROOF DRAIN
SCALE: N.T.S.
THRU-WALL ASSEMBLY DETAIL
A1
SCALE: N.T.S.
ROOF DRAIN CONNECTION
A6
SCALE: N.T.S.
STACK LIGHTNING PRTOTECTION DETAIL
E6
SCALE: N.T.S.
GROUND ROD INSPECTION DETAIL
E11
(SYMBOL )
James.M.Newman
EXISTING SHEET METAL RAIN COLLAR ON RAILING POST (TYPICAL).
BONDING LUG (TYPICAL).
BONDING CONDUCTORS (TYPICAL).
HANDRAIL/PIPE BOND CLAMP (TYPICAL).
BOND TO MAIN CONDUCTOR (TYPICAL).
E-502
E L
E C
T R
I C
A L
D E
T A
I L
S
S
H E
J C
L I N
E
J C
L I N
E
J
N
E W
T O
N
J
N
E W
M A
N
A N
S I
D
N T
S
J A
N
US Army Corps of Engineers
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
N E
W
E
N G
L A
S
T R
I C
T
V
I R
G I N
A
D
C O
N C
O R
D
M
A
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
S C
A L E
S
H E
E T
D R
A W
I N
G
C
O D
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
I S
S U
E
D
A T
E
O F
SHEET ID
M A
R K
D E
S C
R I P
T I O
N D
A T
E
L I G
H T
N I N
G
P
R O
T E
C T
I O
N
R
E P
L A
C E
M E
N T
B L A
C
K
L A
K E
T H
O M
A S
T O
N
C
O N
N E
C T
I C
U T
H O
U B
R
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
W W
J Q
SCALE: N.T.S.
FALL PROTECTION RAILING BONDING DETAIL
K12
KEYNOTES: