Drawings_C26715006.pdf

PDF 7 MB Posted

Attached to
C26715006 WILDER RANCH STATE PARK - Bunkhouse Reroofing
Solicitation number
0000040319
Issued by
Santa Cruz County, California

About this file

Summary of Drawings_C26715006.pdf - Wilder Ranch State Park Bunkhouse Reroofing

This file consists of construction drawings prepared by Joseph Ward Architecture, Inc. for the California Department of Parks and Recreation, Facilities and Development Division, for a historical restoration reroofing project at the Bunkhouse building located at Wilder Ranch State Park in Santa Cruz County, California. The project scope includes replacing the existing wood shingle roof assembly with a new Class A fire-treated wood shingle roof assembly, providing new sheet metal flashings and trims, and repairing or replacing damaged portions of wood gutters and downspouts. The building is classified as an A-3 occupancy (Exhibit) with V-B construction type, contains 2 stories with an actual height of 24'-2½", encompasses 2,480 square feet total building area with 1,463 square feet as the project area, was constructed in 1896, and is located within a fire hazard severity zone. The drawings are prepared at the 100% Construction Documents milestone phase and include a cover sheet, roof plan, elevations with photos, and typical details across four sheets. Contractors must visit the site to verify existing conditions, comply with 2025 California Title 19 CCR and Title 24 regulations including Building Code, Fire Code, and ADA standards, and obtain written clarification from the State's representative for any discrepancies or missing dimensions.

The project specifies that main roofing materials including shingles, cedar breather, cap sheet, and sheathing shall be furnished by Santa Cruz District and are excluded from contractor bidding. Project scheduling is subject to material availability and weather conditions. The job showing is non-mandatory per the Notice to Contractors. Prospective bidders must submit questions or identify discrepancies no later than 2 p.m., seven calendar days prior to bid opening, with responses provided by addendum. A 5% Small Business Preference applies to properly certified small businesses submitting completed STD 811 forms. The DVBE participation requirement has been waived, though the DVBE incentive remains available. All contractors and subcontractors must be registered with the Department of Industrial Relations pursuant to Labor Code section 1725.5 for public works projects.

View the file

Other files

File Type Posted
Bid_Forms_C26715006.pdf PDF
Project_Manual_C26715006.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

THIS PROJECT CONSISTS OF A ROOF REPLACEMENT AT

RESIDENCE #1 AT THE CASWELL MEMORIAL STATE PARK.

1. REPLACE (E) WOOD SHINGLE ROOF ASSEMBLY WITH

NEW CLASS A FIRE TREATED WOOD SHINGLE ROOF

ASSEMBLY.

2. PROVIDE NEW SHEET METAL FLASHINGS AND TRIMS.

3. REPAIR AND/OR REPLACE PORTIONS OF WOOD GUTTERS

& DOWNSPOUTS THAT ARE DAMAGED.

SCOPE OF WORK

CALIFORNIA DEPARTMENT OF PARKS AND RECREATION

FACILITIES AND DEVELOPMENT DIVISION

WILDER RANCH STATE PARK

� SECTION/ELEVATION NUMBER

� DRAWING NUMBER

� DETAIL NUMBER

� DRAWING NUMBER

n DIMENSION LINE

CENTERLINE

n DIMENSION LINE

FACE OF MATERIAL

0 WINDOW TAG

[§I] DOOR TAG

�4 (N) WALL

BUNKHOUSE REROOF

CSFM # 26-N-1540

t> Chico,----•- .,femley Mendocino

National Forest

Mendocino Tahoe

Nattonal Forest

'i Reno • , Fallon t

� >Y Sacramento -0 Santa Rosa

SOnoma o v Napa

� Stockton q San Francisco

• -ti Modesto· <> Fremont

� South Lake •Tahoe

Yosemite National Park Mammoth�-lakes

'tsan Jose -o Merce-d Sierra National

Forest i' Monterey

I

; -.J Fresno

CALIFORNIA

,:, Visalia

Humbolclt-ToIyabe National Forest

--Tonopah

Death "valley National Park

-� i------- - - - - - - -- - - - - - ---- - -�

(E) WALL

Sequoia National Forest

E Q.

"1 i,;' al

1. ALL MATERIALS SHOWN OR NOTED ON THE PLANS ARE NEW

UNLESS CALLED OUT OTHERWISE.

2. THE CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL

EXISTING CONDITIONS SHOWN OR DIMENSIONED HERE.

ANY DISCREPANCIES SHALL BE BROUGHT TO THE

ATTENTION OF THE STATE REPRESENTATIVE FOR

RESOLUTION BEFORE PROCEEDING WITH THAT PORTION OF

THE WORK.

3. ALL WORK SHALL COMPLY WITH THE CURRENT EDITION OF

THE FOLLOWING LISTED CODES, AND ALL OTHERS HAVING

JURISDICTION OVER THE WORK.

TITLE 19, CCR, PUBLIC SAFETY, SFM REGULATIONS

2025 CA ADMINISTRATIVE CODE TITLE 24, PT 1.

2025 CA BUILDING CODE (CBC) TITLE 24, PT. 2.

2025 CA ELECTRICAL CODE (CEC) TITLE 24, PT. 3.

2025 CA MECHANICAL CODE (CMG) TITLE 24, PT. 4.

2025 CA PLUMBING CODE (CPC) TITLE 24, PT. 5.

2025 CA ENERGY CODE CCR TITLE 24, PT. 6.

2025 CA FIRE CODE (CFC) TITLE 24, PT. 9.

2025 CA GREEN BUILDING STANDARDS TITLE 24, PT. 11.

2025 CA REFERENCED STANDARDS TITLE 24, PT. 12.

2010 ADA STANDARD FOR ACCESSIBLE DESIGN

2025 CCR TITLE 19, PUBLIC SAFETY DIVISION 1 STATE FIRE

MARSHAL

4. CONDUCT ALL WORK IN ACCORDANCE WITH THE LATEST

SAFETY RULES AND REGULATIONS OF ALL AUTHORITIES

AND AGENCIES HAVING JURISDICTION OVER THE WORK.

5. ALL WORK SHALL BE IN ACCORDANCE WITH THE

CONSTRUCTION DOCUMENTS. WHERE DETAILED

INFORMATION OR CLARIFICATION IS REQUIRED, THE

MATTER SHALL BE REFERRED TO THE STATE'S

REPRESENTATIVE FOR WRITTEN RESOLUTION.

6. THE CONTRACTOR SHALL NOT SCALE THE DRAWINGS, BUT

SHALL RELY ONLY ON THE WRITTEN DIMENSIONS GIVEN. IF

A DISCREPANCY OCCURS OR NO DIMENSION IS GIVEN, THE

CONTRACTOR SHALL NOTIFY THE STATE'S

REPRESENTATIVE FOR WRITTEN CLARIFICATION BEFORE

PROCEEDING WITH THAT PORTION OF THE WORK.

GENERAL NOTES

-c==:J DEMO WALL

---0 WALL TYPE

0 ROOM INDICATOR

FIN. FLR.'

. .,. ELEVATION DATUM

GENERAL SYMBOLS

AFF ABOVE FINISHED FLOOR

APPROX. APPROXIMATELY

CL CENERLINE

CLR CLEAR

CONG CONCRETE

CONT CONTINUOUS

COL COLUMN

CTR CENTER

DET DETAIL

DS DOWNSPOUT

(E) EXISTING

ELEC ELECTRICAL

FT FOOT

GALV GALVANIZED

GYP BD GYPSUM BOARD

HB HOSE BIB

LF LINEAR FOOT

MANUF MANUFACTURER

MAX MAXIMUM

MTL METAL

(N) NEW

NIC NOT IN CONTRACT

NIS NOT IN SCOPE

NTS NOT TO SCALE

QC ON CENTER

SF SQUARE FOOT

P PENETRATION

PLY PLYWOOD

PT PRESSURE TREATED

RM ROOM

SFM SURFACE MOUNTED

SS STAINLESS STEEL

SYST SYSTEM

TYP TYPICAL

UNO UNLESS OTHERWISE NOTED

VIF VERIFY IN FIELD

VTR VENT THROUGH ROOF

W/ WITH

WD WOOD

ABBREVIATIONS

Morro Bay •�·

Los Padres National Forest o Solvang

I> Ridgecrest

___ '?- Bakersfield 1- D

._----------��---------------------------- -• .-...� ... -+ ... o ............ � ... ------ N

VICINITY MAP .E9,

N

LOCATION MAP.E9,

THIS PROJECT CONSISTS OF EXTERIOR REROOF OF AN

EXISTING A-3 BUILDING. ALL EXITING PATHS, THEIR

CORRESPONDING WIDTHS, LENGTHS AND HEIGHTS AS WELL

AS OCCUPANCIES SERVED SHALL REMAIN UNCHANGED.

THEREFORE, THE FOLLOWING ITEMS ARE NOT APPLICABLE TO

THIS PROJECT.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

FLOOR PLANS IDENTIFYING THE USE AND ROOM NUMBER.

EXITING PLANS IDENTIFYING EGRESS PATHS OF TRAVEL

TO THE PUBLIC ROW.

LOCAL FIRE AUTHORITY ACCESS APPROVAL LETTER.

OCCUPANCY CLASSIFICATION AND USE: A-3 (Exhibit)

BUILDING CONSTRUCTION TYPE: V-B

NUMBER OF STORIES: 2

ACTUAL BUILDING HEIGHT: 24'-2 1/2"±

BUILDING AREA IN SQUARE FEET: 2,480 SF±

AREA OF PROJECT IN SQUARE FEET: 1,463 SF±

SEPARATED OR NON-SEPARATED USE: NON-SEP.

ALLOWABLE AREA PER CBC: UL

ALLOWABLE HEIGHT PER CBC: 40'-0"

AREA INCREASES: NONE

HEIGHT INCREASES: NONE

FIRE SPRINKLERS: NO

FIRE ALARM: NO

OTHER FIRE PROTECTION SYSTEM, IF ANY: NO

SMOKE CONTROL SYSTEM SYSTEM

SMOKE DETECTORS: YES

OCCUPANT LOAD FOR ENTIRE BUILDING: 8

YEAR BUILDING WAS CONSTRUCTED: 1896

FIRE HAZARD SEVERITY ZONE: YES

SEISMIC JOINTS AND LOCATIONS: N/A

EMERGENCY RESPONDER RADIO COVERAGE: YES-SPOTTY

STATE FIRE MARSHAL NOTES

SHEET INDEX

Sheet Number Sheet Title

G•1.0 COVER SHEET

A-2.0 ROOF PLAN

A-3.0 ELEVATIONS & PHOTOS

A-8.0 TYPICAL DETAILS

SHEET INDEX

JOSEPH WARD ARCHITECTURE, INC.

1004 TURNBACK TRAIL

SOUTH LAKE TAHOE, CALIFORNIA 96150

PREPARED BY

Wilder Ranch State Park 1401 Coast Road Santa Cruz, CA 95060

SITE ADDRESS

PROJECT MILESTONE: 100% Construction Documents

FACILITIES AND

DEVELOPMENT DIVISION

ApprQv,1I of InIs µIan OO€s noI Bulhonze or appmv11 11ny orniss1on or deviation from appl1Co!lblu regul.i!ions. Fin<1l llpproval is ::;ubJecI lo f1ald ,ngpeclibn. One seI of approved plans shall tle av11:Ilabla on tile prOfeC1 site al all times

OPR ACCESS COMPLIANCE REVIEW

ACCESSIBILITY SECTION

CERTIFICATION#

Reviewed by Date

ACCESSIBILITY COMPLIANCE AND STATE FIRE MARSHAL

SIGNED ORIGINALS ARE ON FILE AT THE DEPARTMENT OF

PARKS ANO RECREATION, NORTHERN SERVICE CENTER

DESIGNED JSW

DRAWN: JSW

CHECKED:

DATE:

z

0:::

w _J s:

I

03/30/2026

REVISIONS

0:::

w 0 0::: "'C 0 (!) ctl LO z O 0)

- 0::: <(0 - (.)

_J (/)

- ctl " :::) O N Ill O 2 w ,,.... (.)

Cl) 0 ctJ

::::> 'SI" -

O ,,.... fii I Cl)

Ill

I-w w

I (J) c:::

w

SHEET NO.

G-1.0

DATE

V1

B U N K H O U S E W I L D E R R A N C H S T A T E P A R K .

Vivian.Garcia Line

Vivian.Garcia Line