Drawings_C26715006.pdf
PDF 7 MB Posted
- Solicitation number
- 0000040319
- Issued by
- Santa Cruz County, California
About this file
Summary of Drawings_C26715006.pdf - Wilder Ranch State Park Bunkhouse Reroofing
This file consists of construction drawings prepared by Joseph Ward Architecture, Inc. for the California Department of Parks and Recreation, Facilities and Development Division, for a historical restoration reroofing project at the Bunkhouse building located at Wilder Ranch State Park in Santa Cruz County, California. The project scope includes replacing the existing wood shingle roof assembly with a new Class A fire-treated wood shingle roof assembly, providing new sheet metal flashings and trims, and repairing or replacing damaged portions of wood gutters and downspouts. The building is classified as an A-3 occupancy (Exhibit) with V-B construction type, contains 2 stories with an actual height of 24'-2½", encompasses 2,480 square feet total building area with 1,463 square feet as the project area, was constructed in 1896, and is located within a fire hazard severity zone. The drawings are prepared at the 100% Construction Documents milestone phase and include a cover sheet, roof plan, elevations with photos, and typical details across four sheets. Contractors must visit the site to verify existing conditions, comply with 2025 California Title 19 CCR and Title 24 regulations including Building Code, Fire Code, and ADA standards, and obtain written clarification from the State's representative for any discrepancies or missing dimensions.
The project specifies that main roofing materials including shingles, cedar breather, cap sheet, and sheathing shall be furnished by Santa Cruz District and are excluded from contractor bidding. Project scheduling is subject to material availability and weather conditions. The job showing is non-mandatory per the Notice to Contractors. Prospective bidders must submit questions or identify discrepancies no later than 2 p.m., seven calendar days prior to bid opening, with responses provided by addendum. A 5% Small Business Preference applies to properly certified small businesses submitting completed STD 811 forms. The DVBE participation requirement has been waived, though the DVBE incentive remains available. All contractors and subcontractors must be registered with the Department of Industrial Relations pursuant to Labor Code section 1725.5 for public works projects.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bid_Forms_C26715006.pdf | ||
| Project_Manual_C26715006.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
THIS PROJECT CONSISTS OF A ROOF REPLACEMENT AT
RESIDENCE #1 AT THE CASWELL MEMORIAL STATE PARK.
1. REPLACE (E) WOOD SHINGLE ROOF ASSEMBLY WITH
NEW CLASS A FIRE TREATED WOOD SHINGLE ROOF
ASSEMBLY.
2. PROVIDE NEW SHEET METAL FLASHINGS AND TRIMS.
3. REPAIR AND/OR REPLACE PORTIONS OF WOOD GUTTERS
& DOWNSPOUTS THAT ARE DAMAGED.
SCOPE OF WORK
CALIFORNIA DEPARTMENT OF PARKS AND RECREATION
FACILITIES AND DEVELOPMENT DIVISION
WILDER RANCH STATE PARK
� SECTION/ELEVATION NUMBER
� DRAWING NUMBER
� DETAIL NUMBER
� DRAWING NUMBER
n DIMENSION LINE
CENTERLINE
n DIMENSION LINE
FACE OF MATERIAL
0 WINDOW TAG
[§I] DOOR TAG
�4 (N) WALL
BUNKHOUSE REROOF
CSFM # 26-N-1540
t> Chico,----•- .,femley Mendocino
National Forest
Mendocino Tahoe
Nattonal Forest
'i Reno • , Fallon t
� >Y Sacramento -0 Santa Rosa
SOnoma o v Napa
� Stockton q San Francisco
• -ti Modesto· <> Fremont
� South Lake •Tahoe
Yosemite National Park Mammoth�-lakes
'tsan Jose -o Merce-d Sierra National
Forest i' Monterey
I
; -.J Fresno
CALIFORNIA
,:, Visalia
Humbolclt-ToIyabe National Forest
--Tonopah
Death "valley National Park
-� i------- - - - - - - -- - - - - - ---- - -�
(E) WALL
Sequoia National Forest
E Q.
"1 i,;' al
1. ALL MATERIALS SHOWN OR NOTED ON THE PLANS ARE NEW
UNLESS CALLED OUT OTHERWISE.
2. THE CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL
EXISTING CONDITIONS SHOWN OR DIMENSIONED HERE.
ANY DISCREPANCIES SHALL BE BROUGHT TO THE
ATTENTION OF THE STATE REPRESENTATIVE FOR
RESOLUTION BEFORE PROCEEDING WITH THAT PORTION OF
THE WORK.
3. ALL WORK SHALL COMPLY WITH THE CURRENT EDITION OF
THE FOLLOWING LISTED CODES, AND ALL OTHERS HAVING
JURISDICTION OVER THE WORK.
TITLE 19, CCR, PUBLIC SAFETY, SFM REGULATIONS
2025 CA ADMINISTRATIVE CODE TITLE 24, PT 1.
2025 CA BUILDING CODE (CBC) TITLE 24, PT. 2.
2025 CA ELECTRICAL CODE (CEC) TITLE 24, PT. 3.
2025 CA MECHANICAL CODE (CMG) TITLE 24, PT. 4.
2025 CA PLUMBING CODE (CPC) TITLE 24, PT. 5.
2025 CA ENERGY CODE CCR TITLE 24, PT. 6.
2025 CA FIRE CODE (CFC) TITLE 24, PT. 9.
2025 CA GREEN BUILDING STANDARDS TITLE 24, PT. 11.
2025 CA REFERENCED STANDARDS TITLE 24, PT. 12.
2010 ADA STANDARD FOR ACCESSIBLE DESIGN
2025 CCR TITLE 19, PUBLIC SAFETY DIVISION 1 STATE FIRE
MARSHAL
4. CONDUCT ALL WORK IN ACCORDANCE WITH THE LATEST
SAFETY RULES AND REGULATIONS OF ALL AUTHORITIES
AND AGENCIES HAVING JURISDICTION OVER THE WORK.
5. ALL WORK SHALL BE IN ACCORDANCE WITH THE
CONSTRUCTION DOCUMENTS. WHERE DETAILED
INFORMATION OR CLARIFICATION IS REQUIRED, THE
MATTER SHALL BE REFERRED TO THE STATE'S
REPRESENTATIVE FOR WRITTEN RESOLUTION.
6. THE CONTRACTOR SHALL NOT SCALE THE DRAWINGS, BUT
SHALL RELY ONLY ON THE WRITTEN DIMENSIONS GIVEN. IF
A DISCREPANCY OCCURS OR NO DIMENSION IS GIVEN, THE
CONTRACTOR SHALL NOTIFY THE STATE'S
REPRESENTATIVE FOR WRITTEN CLARIFICATION BEFORE
PROCEEDING WITH THAT PORTION OF THE WORK.
GENERAL NOTES
-c==:J DEMO WALL
---0 WALL TYPE
0 ROOM INDICATOR
FIN. FLR.'
. .,. ELEVATION DATUM
GENERAL SYMBOLS
AFF ABOVE FINISHED FLOOR
APPROX. APPROXIMATELY
CL CENERLINE
CLR CLEAR
CONG CONCRETE
CONT CONTINUOUS
COL COLUMN
CTR CENTER
DET DETAIL
DS DOWNSPOUT
(E) EXISTING
ELEC ELECTRICAL
FT FOOT
GALV GALVANIZED
GYP BD GYPSUM BOARD
HB HOSE BIB
LF LINEAR FOOT
MANUF MANUFACTURER
MAX MAXIMUM
MTL METAL
(N) NEW
NIC NOT IN CONTRACT
NIS NOT IN SCOPE
NTS NOT TO SCALE
QC ON CENTER
SF SQUARE FOOT
P PENETRATION
PLY PLYWOOD
PT PRESSURE TREATED
RM ROOM
SFM SURFACE MOUNTED
SS STAINLESS STEEL
SYST SYSTEM
TYP TYPICAL
UNO UNLESS OTHERWISE NOTED
VIF VERIFY IN FIELD
VTR VENT THROUGH ROOF
W/ WITH
WD WOOD
ABBREVIATIONS
Morro Bay •�·
Los Padres National Forest o Solvang
I> Ridgecrest
___ '?- Bakersfield 1- D
._----------��---------------------------- -• .-...� ... -+ ... o ............ � ... ------ N
VICINITY MAP .E9,
N
LOCATION MAP.E9,
THIS PROJECT CONSISTS OF EXTERIOR REROOF OF AN
EXISTING A-3 BUILDING. ALL EXITING PATHS, THEIR
CORRESPONDING WIDTHS, LENGTHS AND HEIGHTS AS WELL
AS OCCUPANCIES SERVED SHALL REMAIN UNCHANGED.
THEREFORE, THE FOLLOWING ITEMS ARE NOT APPLICABLE TO
THIS PROJECT.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
FLOOR PLANS IDENTIFYING THE USE AND ROOM NUMBER.
EXITING PLANS IDENTIFYING EGRESS PATHS OF TRAVEL
TO THE PUBLIC ROW.
LOCAL FIRE AUTHORITY ACCESS APPROVAL LETTER.
OCCUPANCY CLASSIFICATION AND USE: A-3 (Exhibit)
BUILDING CONSTRUCTION TYPE: V-B
NUMBER OF STORIES: 2
ACTUAL BUILDING HEIGHT: 24'-2 1/2"±
BUILDING AREA IN SQUARE FEET: 2,480 SF±
AREA OF PROJECT IN SQUARE FEET: 1,463 SF±
SEPARATED OR NON-SEPARATED USE: NON-SEP.
ALLOWABLE AREA PER CBC: UL
ALLOWABLE HEIGHT PER CBC: 40'-0"
AREA INCREASES: NONE
HEIGHT INCREASES: NONE
FIRE SPRINKLERS: NO
FIRE ALARM: NO
OTHER FIRE PROTECTION SYSTEM, IF ANY: NO
SMOKE CONTROL SYSTEM SYSTEM
SMOKE DETECTORS: YES
OCCUPANT LOAD FOR ENTIRE BUILDING: 8
YEAR BUILDING WAS CONSTRUCTED: 1896
FIRE HAZARD SEVERITY ZONE: YES
SEISMIC JOINTS AND LOCATIONS: N/A
EMERGENCY RESPONDER RADIO COVERAGE: YES-SPOTTY
STATE FIRE MARSHAL NOTES
SHEET INDEX
Sheet Number Sheet Title
G•1.0 COVER SHEET
A-2.0 ROOF PLAN
A-3.0 ELEVATIONS & PHOTOS
A-8.0 TYPICAL DETAILS
SHEET INDEX
JOSEPH WARD ARCHITECTURE, INC.
1004 TURNBACK TRAIL
SOUTH LAKE TAHOE, CALIFORNIA 96150
PREPARED BY
Wilder Ranch State Park 1401 Coast Road Santa Cruz, CA 95060
SITE ADDRESS
PROJECT MILESTONE: 100% Construction Documents
FACILITIES AND
DEVELOPMENT DIVISION
ApprQv,1I of InIs µIan OO€s noI Bulhonze or appmv11 11ny orniss1on or deviation from appl1Co!lblu regul.i!ions. Fin<1l llpproval is ::;ubJecI lo f1ald ,ngpeclibn. One seI of approved plans shall tle av11:Ilabla on tile prOfeC1 site al all times
OPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
CERTIFICATION#
Reviewed by Date
ACCESSIBILITY COMPLIANCE AND STATE FIRE MARSHAL
SIGNED ORIGINALS ARE ON FILE AT THE DEPARTMENT OF
PARKS ANO RECREATION, NORTHERN SERVICE CENTER
DESIGNED JSW
DRAWN: JSW
CHECKED:
DATE:
z
0:::
w _J s:
I
03/30/2026
REVISIONS
0:::
w 0 0::: "'C 0 (!) ctl LO z O 0)
- 0::: <(0 - (.)
_J (/)
- ctl " :::) O N Ill O 2 w ,,.... (.)
Cl) 0 ctJ
::::> 'SI" -
O ,,.... fii I Cl)
Ill
I-w w
I (J) c:::
w
SHEET NO.
G-1.0
DATE
V1
B U N K H O U S E W I L D E R R A N C H S T A T E P A R K .
Vivian.Garcia Line
Vivian.Garcia Line
File details come from the government source that posted it. Updated .