This document is a 1:100 scale drawing showing the proposed roof plumbing work plan for Residence G2 at the US Embassy in Muscat, Oman. The drawing includes details on the planned upgrades to the copper pipe water lines for hot and cold water, as well as the locations of the water tank, pressure pump, and solar water heater. Key requirements include the use of British Standard 8537 copper pipes and fittings, and the use of rubber or polymer-based pipe supports rather than wood. All cold and hot water pipes on the roof will need to be changed.
This drawing is related to a federal contract opportunity for the MCT-FAC Renovation at Residence G2 (X2002), solicitation number PR12678855, issued by the US Department of State. The renovation work includes updates to the kitchen, bathrooms, and fencing at the G2 residence.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 : 100
PROJECT NO.
DRAWN BY APPROVED BY SCALE
DATE DESIGNED BY CHECKED BY
PROJECT
RESI.
USE NO.OF FLOORS LOCATION/AREA
OWNER
SHEET CONTENTS
PLOT NO
BLOCK NO
NOV ; 2023
ONE
US EMBASSY MUSCAT
MADINAT QABOOS
VADAKKATTU GR
GOV - HOUSE G -2 (9-19)
PROPOSED ROOF PLUMBING
G-2 x 2002 - 01
CAR SHADE
PATIO
ROOF
Roof plumbing work plan
Ø15 mm copper pipe water inlet (existing line)
Ø22 mm copper pipe line hot water
Water tank room
WH
Pressure pump
Ø22 mm copper pipe
Existing Solar water heater
Water tank
Ø28 mm copper pipe
Ø22 mm copper pipe water inlet for solar water heater
Hot & cold water
Hot & cold water
Hot & cold water
Kitchen Hot & cold water
Ø22 mm copper pipe outlet for solar water heater
Ø22 mm copper pipe outlet water heater
Ø22 mm copper pipe inlet water heater
All cold and hot water pipe lines need to be insulated by rubber insulation with vapor barrier coating and supported with covering block mounts that are made of heavy duty rubber or polymers designed for outdoor use.
Wood block mounts are not allowed.
Ø22 mm copper pipe line cold water
CARPORT
DWG No:
B - 01
COPPER PIPES AND COMPRESSED PIPE FITTINGS ARE SHALL BE (BRITISH STANDARD 8537)
Bathroom 4 Hot & cold water
Bathroom 3
Bathroom 1
Bathroom 2
All plumbing lines for cold and hot water on the roof shall be changed.
Existing
Existing Ele water heater
Bathroom 5
Hot & cold water
N
PLAN NORTH
| Sheets and Views |
| Model |
File details come from the government source that posted it. Updated .