Drawing_Phase-2_B-01_X2002-01.pdf

PDF 175 KB Posted

Attached to
MCT-FAC Renovation at Residence G2 (X2002)
Solicitation number
PR12678855
Issued by

About this file

This document is a 1:100 scale drawing showing the proposed roof plumbing work plan for Residence G2 at the US Embassy in Muscat, Oman. The drawing includes details on the planned upgrades to the copper pipe water lines for hot and cold water, as well as the locations of the water tank, pressure pump, and solar water heater. Key requirements include the use of British Standard 8537 copper pipes and fittings, and the use of rubber or polymer-based pipe supports rather than wood. All cold and hot water pipes on the roof will need to be changed.

This drawing is related to a federal contract opportunity for the MCT-FAC Renovation at Residence G2 (X2002), solicitation number PR12678855, issued by the US Department of State. The renovation work includes updates to the kitchen, bathrooms, and fencing at the G2 residence.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 : 100

PROJECT NO.

DRAWN BY APPROVED BY SCALE

DATE DESIGNED BY CHECKED BY

PROJECT

RESI.

USE NO.OF FLOORS LOCATION/AREA

OWNER

SHEET CONTENTS

PLOT NO

BLOCK NO

NOV ; 2023

ONE

US EMBASSY MUSCAT

MADINAT QABOOS

VADAKKATTU GR

GOV - HOUSE G -2 (9-19)

PROPOSED ROOF PLUMBING

G-2 x 2002 - 01

CAR SHADE

PATIO

ROOF

Roof plumbing work plan

Ø15 mm copper pipe water inlet (existing line)

Ø22 mm copper pipe line hot water

Water tank room

WH

Pressure pump

Ø22 mm copper pipe

Existing Solar water heater

Water tank

Ø28 mm copper pipe

Ø22 mm copper pipe water inlet for solar water heater

Hot & cold water

Hot & cold water

Hot & cold water

Kitchen Hot & cold water

Ø22 mm copper pipe outlet for solar water heater

Ø22 mm copper pipe outlet water heater

Ø22 mm copper pipe inlet water heater

All cold and hot water pipe lines need to be insulated by rubber insulation with vapor barrier coating and supported with covering block mounts that are made of heavy duty rubber or polymers designed for outdoor use.

Wood block mounts are not allowed.

Ø22 mm copper pipe line cold water

CARPORT

DWG No:

B - 01

COPPER PIPES AND COMPRESSED PIPE FITTINGS ARE SHALL BE (BRITISH STANDARD 8537)

Bathroom 4 Hot & cold water

Bathroom 3

Bathroom 1

Bathroom 2

All plumbing lines for cold and hot water on the roof shall be changed.

Existing

Existing Ele water heater

Bathroom 5

Hot & cold water

N

PLAN NORTH

Sheets and Views
Model

File details come from the government source that posted it. Updated .