Description of Requirement.docx

DOCX document 13 KB Posted

Attached to
Carports
Solicitation number
W50S70-20-R-0008
Issued by

View the file

Other files

File Type Posted
Existing Shelter (3).jpg JPG image
Existing Shelter (4).jpg JPG image
Solcitation W50S70-20-R-0008-0001 Carport.docx DOCX document
Existing Shelter (1).jpg JPG image
Existing Shelter (2).jpg JPG image
Existing Shelter.jpg JPG image
RFI_Template.doc DOC document
Google Earth.png PNG image
IMG_2120.jpg JPG image
IMG_2115.jpg JPG image
Solcitation W50S70-20-R-0008 Carport.docx DOCX document
IMG_2116.jpg JPG image
IMG_2119.jpg JPG image
IMG_2117.jpg JPG image
IMG_2118.jpg JPG image
Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Description of Work:

Contractor will provide four (4) custom length metal roof carport with a Gable or A-Frame style roof with a minimum of 12 gauge metal.

1st carport will be 150 ft. in length and 25 ft. in width. This carport will have 15 bays that are approx. 10 ft. wide and a height clearance of 12 ft. in each bay.

2nd carport will be 144 ft. in length and 30 ft. in width. This carport will have 12 bays that are approx. 12 ft. wide and a height clearance of 12 ft. in each bay

3rd carport will be 132 ft. in length and 30 ft. in width. This shed will have 11 bays that are approx. 12 ft. wide and a height clearance of 12 ft. in each bay

4th carport will be 40 ft. in length and 40 ft. in width with a 12ft height clearance.

All carport will be a standard tan military color. Each carport will have 2 sides covered. One Length side and one width side. Carport are to be delivered to the 117 ACS and installed on the compound.

Contractor is required to install according to the following standards and provide certification of the following from a licensed/certified engineer in the state of Georgia. Sheds shall be anchored to the ground and must ensure structures remain anchored for wind of (3 second) peak gust speeds up to and including 115 mph as measured at 10 meters above ground (reference ASCE 7-10). Meteorological conditions and wind speed shall be as measured by KSVN METAR weather recordings at the Hunter Army Airfield Airport Control Tower.

Carport cannot have subgrade foundations poured and vertical load transfer elements below subgrade.

Incidental construction (minor concrete anchoring pads/column supports to facilitate shed anchoring) and/or site prep necessary to execute the installation of this equipment to obtain the required engineered anchorage is approved.

Placement of equipment cannot be within 10’ of an installation controlled perimeter fence

Dig permit is required from 165CES Work Control before breaking surface of the ground including drilling bolts into ground or any subsurface digging/coring is undertaken.