This document includes a sanitary layout drawing and details for a federal contract opportunity to provide sterile processing service equipment. The opportunity will be awarded by the Department of Veterans Affairs Network Contracting Office 8 Orlando to support the VA Caribbean Healthcare System and Ponce Outpatient Clinic in Puerto Rico. Services required include sterile processing equipment for facilities in Ponce and San Juan. The primary NAICS code is 339113 for surgical appliance and supplies manufacturing. The set-aside is for service-disabled veteran-owned small businesses. The solicitation will be posted on or around June 30, 2022 via the Opportunities website using provisions from FAC 2022-06. Interested parties must register in SAM to be eligible for award. The drawing provides plumbing details for specific rooms and equipment in support of the sterile processing needs.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCALE: 1/4"=1'-0"

VA FORM 08 - 6231

SANITARY LAYOUT

SPS AREA - ENLARGED FLOOR PLAN,

A

Fi le

C ad

H os pi ta le s\ V

A \P on ce

A m bu la to ry

\P lu m bi ng \V

A P on ce

A m bu la to ry

-P

3.

FC

W

PLUMBING

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

STAMP

PONCE, PUERTO RICO

VA101-16-R-0028

Project Director

J. LEDON A. SEDARevisions: Date:

AJM Management LLC

PO BOX 13922

SAN JUAN, PR 00908

ARCH. MIGUEL E. CALZADA

A/E:

MIGUEL CALZADA ARQUITECTOS

MCLEARY 2004, 1ST LEVEL

SAN JUAN, PUERTO RICO, 00911

787-727-8203

A/E firm POC i g elu alz ada arquitec tos

CONSULTANT

CONSULTING MECHANICAL ENGINEER

JORGE LEDON WEBSTER

CENTRO INTERNACIONAL DE MERCADEO

TORRE 1, SUITE 604 GUAYNABO P.R. 00968

TEL. (787) 707-1350 / FAX: (787) 707-1353

email address: jorge@jlw-eng.com

INGENIERO

LICENCIADO

LIC. #8812

ODELEGROJ RE

TS

BEWN

TORICOPUER

P-113

75% ADVANCED CONST. DOCUMENTS 04/11/2019

FIRST DESIGN DEVELOPMENT 11/07/2018

A

B B.2

C

C.8

D

E

F

G

H

J

J.9

K

L

N

I

M

O

P

Q

10 11 12 13

NOT TO SCALE

KEY PLAN

SLOPE IN WASH ROOM & DECON ROOM

SHALL BE NOT LESS THAN 1/8" = 1'-0"

AND NO GREATER THAN 1/4" = 1'-0"

NOTE:

ZONE A ZONE B

ZONE C ZONE D

ZONE E

Issue Date

100% CONSTRUCTION

DOCUMENTS

08-09-2019

Department of Veterans Affairs Outpatient Clinic

Euripides Rubio

ID

ID

L

T L

NEW

NEW

NEW

NEW

1H-145

HAC

1H-241

SERV ORG REP - FT

1H-243

SERV ORG STO

1H-245

SERV ORG REP - FT

1H-247

SEC OFC

1E-197

URODYNAMICS EXAM

1E-195

P TLT

1E-196

P TLT

1K-124

IDF

1K-112

ELECTRICAL

1J-103

BOH CORR

1J-102

BOH CORR

1H-223

SOILED HAC

1E-180

CYSTO

1E-182

DECON

1E-193

P TLT

C O

R R

1E-221

CLEAN LINEN

1H-225

CART WASH

1H-226

STERILE PROCESSING

1H-234

CLEAN HAC

1H-230

CLEAN LCKR/TLT/SHWR

1H-229

CLEAN STERILE/ NON-STERILE STO/ DISPACH

1H-231

ANTEROOM

1H-224

SOILED RCVG & DECON

1H-222

SOILED LCKR/TLT/SHWR

1H-221

ANTEROOM

1E-181

SCOPE-AER

1H-232

COOL DOWN STERILIZER ROOM

M a tc h

L in e D w g

P -1

Match Line Dwg. #1 / P-113

M a tc h

L in e D w g

P -1

1-1/2" V.S.

2" C.O.-2

1-1/2" V.S.

2" C.O.-2

2"ø

1-1/2" V.S.

1-1/2" V.S.

1-1/2" V.S.

2" V.T.R.

4" C.O.-1

4" C.O.-1

2" C.O.-2

2" C.O.-2

1-1/2" V.

2"ø

4"ø

3"ø 2"ø

2"ø

4" C.O.-1

2" C.O.-2

4" F.D.-S

4" F.D.-S

4" F.D.-R

4" F.D.-S 4" C.O.-1

4"ø

2" V.T.R.

4" C.O.-1

3" F.D.-_

3" F.D.-_

4" F.D.-R

4" F.D.-R

4" F.D.-R

4" F.D.-R

2" V.T.R.

4" C.O.-1

2" C.O.-2

1-1/2" V.S.

2" C.O.-2

4" F.D.-S

3" F.D.-L

3"ø

AIR COMPRESSOR

BOILER

4" F.D.-34" F.D.-3

4" C.O.-1

4" C.O.-1

4" C.O.-1

BLOWDOWN SEPARATOR

WILSON ENG. CO. 8" x 15"

WITH 1" AUTOMATIC

AFTERCOOLER

FOR SOFTENER & FILTER DETAIL

SEE DETAIL #3/ P-400

FOUR BED MIXED

BED DI UNIT CULIGAN

MODEL: PEDI

STAINLESS STEEL

AUTOMATIC FLUSHING

VALVE CABINET. FOR

DETAIL SEE DWG. #12 / P-500

1"ø C.W. LINE

2"ø

4"ø

4"ø 4"ø

4"ø

4"ø

4"ø

1-1/2" V.S.

1-1/2" V.

2" V.

2" V.

1-1/2" V.S.

FOR DETAIL SEE

DWG. #12 / P-500.

2" C.O.-2

2" F.D.-___

2" C.O.-2

2" V.T.R. 1-1/2" V.S.

4"ø 2" V.

4"ø

4"ø

4"ø

4"ø

2"ø

2" V. 2" V.2" V.

2"ø4"ø2"ø

2"ø

4"ø4"ø 4"ø

4"ø SAN.4"ø SAN.4"ø SAN.4"ø SAN.4"ø SAN.4"ø SAN.4"ø SAN.

2" V.S.

4"ø

4"ø

4"ø

4"ø

2" V.S.

2" V.

2" V.

1-1/2" V.S.

2" C.O.-2

3"ø 3"ø

2"ø

2" C.O.-2

1-1/2" V.S.1-1/2" V.

2" V.S.

2" V.T.R.

2" V.

2" V.S.

3"ø

3"ø

4"ø

3"ø

4"ø

2" V.

4"ø

4"ø

4"ø

4"ø

3"ø

4"ø

4"ø

1-1/2" V.S.

1-1/2" V.

1-1/2" V.S.

1-1/2" V.

1-1/2" V.

SEE NOTE 1

SEE NOTE 1

1-1/2" V.

2"ø

4"ø

4"ø

G H I J J.9 K

2" V.

2" V.

1-1/2" V.S.4" C.O.-1

4" C.O.-1

3" F.D.-_

3" F.D.-_ 2" V.S.

4" F.D.-3

GENERAL REVISION 01/24/2020

4"ø HUB DRAIN

4"ø