CT Sim Bid Set DWGs - Stamped.pdf

PDF 22 MB Posted

Attached to
Z2DA--642-CSI-802 Site Prep for CT Sim Federal contract opportunity
Solicitation number
36C24422B0002
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4

About this file

This document provides details for a federal contract solicitation for site preparation work for a CT simulator project. The Department of Veterans Affairs Medical Center in Philadelphia is soliciting bids for demolition and removal of existing structures to prepare the site for a new CT simulator. The project scope includes all labor, materials, tools, equipment, permits, testing and reports required. The estimated value of the construction project is between $250,000 and $500,000. The period of performance is approximately 100 calendar days after issuance of the notice to proceed. This solicitation is set aside solely for service-disabled veteran small businesses. The relevant NAICS code is 236220 for commercial and institutional building construction, and the small business size standard is $36.5 million. A pre-proposal conference and site visit will be held within two weeks of solicitation issuance. The solicitation documents will be posted on FBO.gov on or around November 2, 2021. Questions should be directed to the named contracting specialist and reference the solicitation and project numbers. This procurement is subject to availability of funds.

View the file

Other files for this federal contract opportunity

Other files attached to Z2DA--642-CSI-802 Site Prep for CT Sim, newest first.
File Type Posted
36C24422B0002 0002.docx DOCX document
36C24422B0002 0001.docx DOCX document
CT Sim Bid Set Spec V2.pdf PDF
36C24422B0002_1.docx DOCX document
CT Sim BID SET Spec V1.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VAMC PHILADELPHIA

NORTH

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date:

CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Architect:

CB DESIGN GROUP, INC.

11720 Beltsville Drive, Suite 350 Calverton, Maryland 20705 443.388.7351 POC: Ken Jones

Consultant:

HF LENZ

1407 SCALP AVENUE

JOHNSTOWN, PA 15904

814-2269-9300

POC: ROBERT MICKLE A R C H I T E C T S E N G I N E E R S

H.F. LENZ COMPANY

1407 Scalp Avenue Johnstown, PA 15904

Phone: 814-269-9300 FAX: 814-269-9301 cadd@hflenz.com www.hflenz.com Engineers - Planners - Surveyors - Energy Consultants Corporal Michael J. Crescenz VAMC

3900 Woodland Ave, Philadelphia, PA 19104

09-20-2021

642-CSI-802

DRKBJ

SITE PREP TO REPLACE CT

SIMULATOR

BID SET

TITLE SHEET

GI100

-C

S I-

G I1

.p d f

00 - GENERAL

GI100 TITLE SHEET

GI200 SYMBOLS, ABBREVIATIONS & NOTES

GI300 GENERAL NOTES

GC200 EXISTING CONDITIONS PLAN

GC201 LIFE SAFETY PLAN

GC300 PHASING PLANS - ICRA

GC400 LEAD SHIELDING PLANS

06 - ARCHITECTURAL

AD100 DEMOLITION PLAN

AE100 FLOOR PLANS

08 - EQUIPMENT

QH100 EQUIPMENT PLANS - ARCHITECTURAL - SIEMENS

QH101 EQUIPMENT PLANS - STRUCTURE - SIEMENS

QH102 EQUIPMENT PLANS - ELECTRICAL - SIEMENS (1 OF 2)

QH103 EQUIPMENT PLANS - ELECTRICAL - SIEMENS (2 OF 2)

Department of Veterans Affairs

SITE PREP TO REPLACE CT SIMULATOR

CORPORAL MICHAEL J. CRESCENZ VA MEDICAL CENTER

3900 WOODLAND AVE, PHILADELPHIA, PA 19104

LOCATION MAP DRAWING LIST

APPLICABLE CODES PROJECT CONTACT DIRECTORY

Approved by Medical Center Director Approved by Director of Facility Management Service

Approved by Medical DirectorApproved by Project COR

Approved by Project CO

Approved by Infection Control

Approved by Radiation Oncology

Approved by Safety Officer

CONTRACTING OFFICER REPRESENTATIVE (COR)

ARCHITECT

MEP/FP/STRUCTURAL ENGINEER

ANJU ELIAS

Corporal Michael J. Crescenz VAMC 3900 Woodland Ave, Philadelphia, PA 19104 PHONE: (W) 215-823-5800 x 207517 Anju.Elias@va.gov

CB DESIGN GROUP, INC

11720 Beltsville Drive, Suite 350 Calverton, MD 20705

PHONE: (443) 388-7351

kjones@cbdg-ae.com

HF LENZ COMPANY

1407 Scalp Avenue Johnstown, PA 15904

PHONE: (814) 269-9300

RMickle@hflenz.com

CONTRACTING OFFICER (CO)

EVERETT SHAVER

Contracting Officer, Construction-East (VISN 4 Eastern Market) Department of Veterans Affairs / Service Area Office East / Network Contracting Office 4 1111 East End Blvd, Wilkes-Barre, PA 18711 PHONE: (W) 302-994-2511 x 7526 everett.shaver@va.gov

MASTER CONSTRUCTION SPECIFICATIONS (PG-18-1)

LIFE SAFETY CODE NFPA 101 - 2018

ARCHITECTURAL BARRIERS ACT ACCESSIBILITY

STANDARDS

VA DESIGN MANUALS:

FIRE PROTECTION, EIGHTH EDITION - JUNE

INTERIOR DESIGN MANUAL, NOVEMBER 2020

VA BARRIER FREE DESIGN STANDARD (PG-18-13),

REV 11/1/18

NATIONAL ELECTRIC CODE - LATEST VERSION

PROJECT #642-CSI-802

09 - STRUCTURAL

S001 STRUCTURAL NOTES & ABBREVIATIONS

SF101 STRUCTURAL SUB-BASEMENT FRAMING PLAN & DETAILS

10 - MECHANICAL

M001 MECHANICAL NOTES, SYMBOLS, & ABBREVIATIONS

MD101 MECHANICAL DUCTWORK SUB-BASEMENT PLAN - DEMOLITION

MD102 MECHANICAL PIPING SUB-BASEMENT PLAN - DEMOLITION

MH201 MECHANICAL DUCTWORK SUB-BASEMENT PLAN -NEW WORK

MH202 MECHANICAL PIPING SUB-BASEMENT PLAN - NEW WORK

M501 MECHANICAL DETAILS (1 OF 2)

M502 MECHANICAL DETAILS (2 OF 2)

M601 MECHANICAL SCHEDULES AND CONTROLS

11 - PLUMBING

P201 PLUMBING SUB-BASEMENT PLAN -NEW WORK

12 - FIRE PROTECTION

F201 FIRE PROTECTION SUB-BASEMENT PLAN - NEW WORK

14 - ELECTRICAL

E001 ELECTRICAL NOTES, SYMBOLS, & ABBREVIATIONS

ED101 ELECTRICAL SUB-BASEMENT PLAN - DEMOLITION

EL201 ELECTRICAL SUB-BASEMENT PLAN - LIGHTING

EP301 ELECTRICAL SUB-BASEMENT PLAN - POWER & SIGNAL

EP302 ELECTRICAL SUB-BASEMENT PLAN - IMAGING EQUIPMENT PLAN

EP401 ELECTRICAL RISER DIAGRAM

E501 ELECTRICAL DETAILS (1 OF 2)

E502 ELECTRICAL DETAILS (2 OF 2)

E601 ELECTRICAL SCHEDULES

WOOD

ALUMINUM

STEEL

EARTH

CONCRETE MASONRY UNITS

RIGID INSULATION

CONCRETE

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO BE REMOVED

BRICK

WOOD-FINISHED

WOOD ROUGH

PLYWOOD

GYPSUM - PLASTER

ACOUSTIC TILE

CAST STONE

ALL METALS - SMALL SCALE

GLASS - LARGE SCALE

BATT INSULATION

CERAMIC TILE

CARPET

GRAVEL

CENTER LINE

DETAIL INDICATOR

DETAIL INDICATIOR

DETAIL INDICATOR FOR SMALL CONDITIONS

DIMENSION LINE

NEW DOOR OPENING / BORROWED LIGHT

INDENTIFIER

DRAWING BLOCK TITLE, TYPICAL

ELEVATION INDICATOR, EXTERIOR

ELEVATION INDICATOR, INTERIOR, MULTIPLE VIEW

ELEVATION INDICATOR, INTERIOR, SINGLE VIEW

SECTION INDICATOR

TYPICAL DETAIL INDICATOR

FURNITURE, FIXTURE, & EQUIPMENT INDICATOR

COLUMN GRID

KEYNOTE

WALL OR PARTITION TYPE

FIRE EXTINGUISHER CABINET

NORTH ARROW

FEC

A

DETAIL NUMBER

SHEET WHERE

DRAWN

XXxxx

XXxxx

X

DRAWING TITLE

SCALE: 1 1/2" = 1'-0"

1 3/16"

D2

XX-XX

XXxxx

XXxxx

CL

XXxxx x'-x" VERTICAL HEIGHT INDICATOR

REVISION

REVISION CLOUD

NORTH

BREAK LINE

X

DEMOLITION KEYNOTE

NEW ROOM NAME AND NUMBERCORRIDOR

C2

XX

A

XXxxx

D

BC

COLUMN NUMBER

COLUMN LETTER

XXxxx

ELEVATION NUMBER

SHEET WHERE

DRAWN

ELEVATION NUMBER

SHEET WHERE

DRAWN

ELEVATION NUMBER

SHEET WHERE

DRAWN

DETAIL NUMBER

SHEET WHERE DRAWN

DETAIL NUMBER

SHEET WHERE DRAWN

WALL MOUNTED FIRE EXTINGUISHERFE

XX

SHEET WHERE

DRAWN

ELEVATION NUMBER

& AND

@ AT

C CENTERLINE

# NUMBER

AB ANCHOR BOLT

ABV ABOVE

ACT ACOUSTIC CEILING TILE

AD AREA DRAIN

ADA AMERICANS WITH

DISABILITIES ACT

ADJ ADJUSTABLE

AFF ABOVE FINISHED FLOOR

AHU AIR HANDLING UNIT

AIA AMERICAN INSTITUTE OF

ARCHITECTS

ALUM ALUMINUM

ALT ALTERNATE

AP ACCESS PANEL

APPROX APPROXIMATE

ARCH ARCHITECTURAL

AUTO AUTOMATIC

AVG AVERAGE

BD BOARD

BLDG BUILDING

BLK BLOCK

BM BEAM

BOT BOTTOM

BRG BEARING

BEL BELOW

BR BUMPER RAIL

BRK BRICK

CAB CABINET

CB CATCH BASIN

CEM CEMENT

CCT CUBICLE CURTAIN TRACK

CG CORNER GUARD

CI CAST IRON

CIP CAST IN PLACE

CJ CONTROL JOINT

CT CERAMIC TILE

CLG CEILING

CL CLOSET

COL COLUMN

CONC CONCRETE

CONF CONFERENCE

CONT CONTINUOUS

CPT CARPET

CT CERAMIC TILE

CU CUBIC

DBL DOUBLE

DEMO DEMOLITION

DEPT DEPARTMENT

DET DETAIL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIM DIMENSION

DISP DISPENSER

DN DOWN

DO DOOR OPENING

DOZ DOZEN

DP DAMPPROOFING

DR DOOR

DWG DRAWING

DWGS DRAWINGS

DWR DRAWER

E EAST

EA EXHAUST AIR, EACH

EL ELEVATION

ELEV ELEVATION

ELEC ELECTRICAL

EMER EMERGENCY

ENCL ENCLOSURE

ENGR ENGINEER

EP ELECTRICAL PANELBOARD

EQ EQUAL

EQUIP EQUIPMENT

EWC ELECTRIC WATER COOLER

EWS EYE WASH STATION

EXP EXPANSION

EJ EXPANSION JOINT

EXIST EXISTING

EXT EXTERIOR

FA FIRE ALARM

FB FACE BRICK

FD FLOOR DRAIN

FDC FIRE DEPARTMENT

CONNECTION

FDN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER

CABINET

FF FINISH FACE

FHC FIRE HOSE CABINET

FIN FINISH

FLR FLOOR

FLUOR FLUORESCENT

FO __ FACE OF __

FOC FACE OF CONCRETE

FOS FACE OF STUD

FOW FACE OF WALL

FPRF FIREPROOF(ING)

FR FIRE RATING, FRAME

FRMG FRAMING

FS FULL SIZE

FT FOOT OR FEET

FTG FOOTING

FUR FURRING

FUT FUTURE

GA GAUGE

GAL GALLON

GALV GALVANIZED

GALV STL GALVANIZED STEEL

GB GRAB BAR

GC GENERAL CONTRACTOR

GD GUARD

GL GLASS

GND GROUND

GR GRADE

GWB GYPSUM WALLBOARD

GYP BD GYPSUM WALLBOARD

HB HOSE BIBB

HC HOLLOW CORE

HD HEAD

HDWR HARDWARE

HDWD HARDWOOD

HT HEIGHT

HNDRL HANDRAIL

HM HOLLOW METAL

HMD HOLLOW METAL DOOR

HMF HOLLOW METAL FRAME

HR HANDRAIL

HO HOLD OPEN

HORIZ HORIZONTAL

HP HIGH POINT

HR HOUR

HVAC HEATING, VENTILATION, AIR

CONDITIONING

IBC INTERNATIONAL BUILDING CODE

ID IDENTIFICATION, INSIDE

DIAMETER / DIMENSION

IN INCH

INCL INDLUDE(D)

INSUL INSULATION

INT INTERIOR

INV INVERT

JAN JANITOR

JST JOIST

JT JOINT

KP KICK PLATE

KO KNOCKOUT

L LENGTH

LAB LABORATORY

LAM LAMINATE

LAV LAVATORY

LBS POUND

LED LIGHT EMITTING DIODE

LF LINEAR FEET

LH LEFT HAND

LIN LINEAR

LIQ LIQUID

LKR LOCKER

LG LONG

LL LEAD LINED

LLV LONG LEG VERTICAL

LP LOW POINT

LRG LARGE

LT LIGHT

LT WT LIGHTWEIGHT

LVR LOUVER

MATL MATERIAL

MAS MASONRY

MAX MAXIMUM

MECH MECHANICAL

MTL METAL

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MO MASONRY OPENING

MP MOP PLATE

MTD MOUNTED

N NORTH

NA NOT APPLICABLE

NEC NATIONAL ELECTRICAL CODE

NEG NEGATIVE

NFC NATIONAL FIRE CODE

NFPA NATIONAL FIRE PROTECTION

ASSOCIATION

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

OA OVERALL

OC ON CENTER

OD OUTSIDE DIAMETER / DIMENSION

OFF OFFICE

OH OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

OH OVERHEAD

OZ OUNCE

PAV PAVING

PC PRECAST CONCRETE

PL PLATE

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLYWD PLYWOOD

PLBG PLUMBING

PMF PREMOLDED FILLER

PR PAIR

PT POINT

PTN PARTITION

QT QUARRY TILE

R RADIUS, RISER

RA RETURN AIR

RAD RADIUS

RB RESILIENT BASE, RUBBER

BASE

RD ROOF DRAIN

RL ROOF LEADER

REF REFERENCE

REFR REFRIGERATOR

REQ'D REQUIRED

REV REVISION

RFI REQUEST FOR

INFORMATION

RFP REQUEST FOR PROPOSAL

RH RIGHT HAND

RM ROOM

RO ROUGH OPENING

S SOUTH

SA SUPPLY AIR

SAN SANITARY

SC SOLID CORE

SCHED SCHEDULE

SECT SECTION

SH SPRINKLER HEAD

SHT SHEET

SIM SIMILAR

SM SMOKE

SPEC SPECIFICATION

SPKR SPEAKER

SQ SQUARE

STA STATION

STD STANDARD

STO STORAGE

STL STEEL

SS STAINLESS STEEL

STOR STORAGE

STRUCT STRUCTURAL

SUSP SUSPENDED

SYM SYMMETRICAL

SYS SYSTEM

T TREAD

TEL TELEPHONE

TEMP TEMPERED

T&G TONGUE AND GROOVE

THK THICK

TOC TOP OF CONCRETE

TOP TOP OF PAVEMENT

TOS TOP OF STEEL

TOW TOP OF WALL

TV TELEVISION

TYP TYPICAL

UNFIN UNFINISHED

UON UNLESS OTHERWISE

NOTED

VB VAPOR BARRIER

VERT VERTICAL

VCT VINYL COMPOSITION TILE

VIF VERIFY IN FIELD

VTR VENT THRU ROOF

W WEST

W/ WITH

WD WOOD

W/O WITHOUT

WP WATERPROOF

WT WEIGHT

WWF WELDED WIRE FRAME

NOTE: ALL ABBREVIATIONS SHOWN

MAY NOT BE USED ON THIS PROJECT.

CERTAIN COMMON ABBREVIATIONS

MAY NOT BE SHOWN.

L

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date:

CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Architect:

CB DESIGN GROUP, INC.

11720 Beltsville Drive, Suite 350 Calverton, Maryland 20705 443.388.7351 POC: Ken Jones

Consultant:

HF LENZ

1407 SCALP AVENUE

JOHNSTOWN, PA 15904

814-2269-9300

POC: ROBERT MICKLE A R C H I T E C T S E N G I N E E R S

H.F. LENZ COMPANY

1407 Scalp Avenue Johnstown, PA 15904

Phone: 814-269-9300 FAX: 814-269-9301 cadd@hflenz.com www.hflenz.com Engineers - Planners - Surveyors - Energy Consultants Corporal Michael J. Crescenz VAMC

3900 Woodland Ave, Philadelphia, PA 19104

09-20-2021

642-CSI-802

DRKBJ

SITE PREP TO REPLACE CT

SIMULATOR

BID SET

SYMBOLS, ABBREVIATIONS & NOTES

GI200

-C

S I-

G I2

.p d f

SYMBOLS OF MATERIALS DRAWING KEY ARCHITECTURAL ABBREVIATIONS

G1 Items and conditions noted, detailed, or otherwise identified on drawings are applicable and binding to similar conditions on all drawings. For conditions not noted or not detailed, provide materials of equal quality and performance to other similar conditions on the job.

G2 Sections shown are intended to show the specific construction where indexed as well as establish the general construction details for sections throughout the project which do not have specific sections drawn. The most similar section shall be adapted to any section not detailed. Any specific questions concerning construction not adequately covered by the above should be directed to the Architect during the bid period.

G3 All construction is to be assumed new and furnished and installed by the Contractor, unless noted otherwise.

G4 Refer to mechanical and electrical drawings for notes pertaining to their particular trades. Coordinate the work of all trades and report to the Architect any perceived discrepancies. Contractor shall be responsible for establishing sequences of construction and means and methods for how to perform the Work required in the Contract Documents. All Contractors shall carefully review all existing conditions and determine the most feasible sequence for performing the new Work so as to avoid conflicts in the field.

G5 Any areas or spaces not clearly defined or indicated by notes shall be of same material and finish as areas of similar use or function elsewhere in the building.

G6 Wall and ceiling finishes shall include projections, beam enclosures, recesses, bulkheads, pilasters and other similar items.

G7 All appurtenances built into or through walls, including doors, windows, ducts, frames, louvers, grilles, mechanical work, etc., shall fit snugly and be thoroughly sealed around perimeters. Install fire sealant around all penetrations through floors, fire rated walls and smoke partitions.

Work at exterior walls shall be flashed or otherwise waterproof sealed.

G8 Field check rough and/or finished dimensions for accurate fitting of cabinets, counters, storefront, doors, frames, fixtures, millwork and all other installations prior to shop or factory fabrication. Provide and install necessary filler strips, scribe strips, bases, closures, finishes and trim to complete such installations. Dimensions of such installations shall be considered "nominal". Contractors shall account for all manufacturer's required tolerances, clearances and shim space to ensure proper installation of the new Work.

G9 See equipment plans and floor plans for casework, cabinets, millwork and other built-in items. Coordinate with MEP drawings for sinks, outlets, and other items to be built into such items.

G10 If a discrepancy appears to exist between drawings of different scales, consult Architect for clarification.

G11 If a discrepancy appears to exist between drawings and/or specifications, the more stringent (typically the more costly) requirement shall apply. Items described on drawings, but not specified, shall be provided. Contractor shall be responsible to submit an RFI to seek clarification of any perceived discrepancy during bid phase.

G12 Written information on drawings takes precedent over drawing lines.

G13 In the absence of a written dimension, or in case of doubt as to the proper measurement, consult Architect. DO NOT SCALE DRAWINGS.

Assumptions made, or actions taken, based on scaled dimensions shall be at the Contractor's risk and any resulting corrections shall be performed by Contractor at no additional cost to the Government.

G14 Each Contractor or Sub-Contractor shall be responsible for coordinating with the Work of other trades shown throughout the complete set of Contract Documents. Changes resulting from a Contractor or Sub-Contractor's failure to obtain and review a complete set of Contract Documents shall be corrected at no additional cost to the Government.

G15 At all changes in floor finishes, provide and install an appropriate transition strip as shown on the drawings.

G16 Consult HVAC and Electrical drawings for locations and descriptions of access panels, louver openings, ventilators, grilles, valve cabinets, fire dampers or other appurtenances affecting walls, ceilings or floors and provide necessary lintels, support or anchoring.

G17 Electric switches, outlets, thermostats, controls, clocks, speakers, or other wall-mounted accessories shall be installed in locations which are unobstructed by cabinets, counters, racks, marker and tackboards, fixtures, shelving or other furnishing or equipment designated for spaces shown on drawings. Items for wall-mounting are not to be installed on, through, or into, any equipment other than walls, unless specifically noted otherwise.

G18 Electrical outlets, clocks, P.A. speakers, pull stations, exit signs, or other devices shown diagrammatically on the architectural drawings serve to alert Contractors of the presence of such devices. Consult the electrical drawings for further information and advise Architect of any perceived discrepancy between architectural and electrical drawings regarding location or type of devices shown prior to preparing submittals.

G19 Electric switches, thermostats or other electronic controls in the same vicinity shall be mounted at the same height from floor (unless noted otherwise) in a uniform, orderly fashion.

G20 SUBMITTAL REVIEW - The Contract Documents provide sizes, dimensions, product requirements, etc. Contractor shall verify that submittals are coordinated with the requirements of the Contract Documents prior to submission. A/E review of submittals is NOT FOR THE PURPOSE OF DETERMINING THAT SIZES, DIMENSIONS, ETC MATCH WHAT HAS ALREADY BEEN PROVIDED IN THE CONTRACT DOCUMENTS. All deviations from what is shown on the Contract Documents shall be clouded on the submittal or otherwise clearly brought to the attention of the reviewer. Failure to clearly bring any deviation(s) to the attention of the reviewer shall be understood by all parties that what is shown in the submittal complies with the Contract Documents regardless of whether or not the reviewer discovers the deviation. Changes resulting from the Contractor's failure to clearly identify deviations in submittals shall be the Contractor's sole responsibility and shall be corrected by the Contractor at no additional cost to the Government.

G21 Contractors shall carefully review existing field conditions and coordinate all quantities, dimensions, and tolerances required to perform the work shown on the Contract Documents. Contractor is responsible for determining information that pertains solely to fabrication processes, installation techniques (means and methods), and sequencing of the Work to meet the requirements of the project schedule. Each subcontractor shall coordinate with other trades prior to beginning their portion of the Work.

G22 Public exits shall remain clear at all times while the building is occupied. No storage shall be permitted in the exit access.

G23 Patch all holes in floors, walls and ceilings within the project limits after demolition and new work is complete.

G24 Unless specific dimensions are provided, MEP drawings are considered "diagrammatic". It is the sole responsibility of the Contractor(s) to field coordinate locations, sequences, etc for unobstructed installation of items that are shown on MEP drawings in diagrammatic form.

Coordinate above-ceiling work of MEP trades so that each trade locates their work as tight to the structure / deck above as is feasible. Each successive trade shall locate their work as tight to the trade before.

G25 The Drawings and Specifications are complimentary and NEITHER shall take precedent over the other. What is required by either the Drawings or Specifications shall be interpreted as being required as part of the Scope of Work for this project. Items specified, but not indicated on the drawings, shall be provided. Items shown on the drawings, but not specified, shall be provided. It is the sole responsibility of the Contractor to seek clarification prior to submitting a bid amount if there should appear to be a discrepancy between drawings and/or the specifications. Otherwise, the most stringent (typically the most expensive) requirement shall apply at the discretion of the COR.

G26 Contractor to verify with FMS and remove all dead and decommissioned MEP work encountered.

G27 All mechanical, electrical, plumbing, med air/gas/vac shutdowns require a minimum two weekreview time and can take as long as four weeks. Present shutdown requests to the project COR in a timely and detailed manner.

1. HOSPITAL STAFF SHALL ENSURE THE REMOVAL OF ANY MEDICAL WASTE, INCLUDING SHARPS CONTAINERS, FROM AREAS

TO BE RENOVATED, PRIOR TO THE START OF THE PROJECT.

2. INFECTION CONTROL SHALL BE NOTIFIED BY FACILITIES MANAGEMENT STAFF IMMEDIATELY IF UNEXPECTED MEDICAL

WASTE IS ENCOUNTERED.

IN STRIVING TO PROVIDE A HEALTHY AND SAFE ENVIRONMENT AT VA FACILITIES, VHA IS IMPLEMENTING A SMOKE-FREE POLICY FOR ALL VHA HEALTH CARE FACILITIES AND PROPERTY ASSIGNED TO VHA THAT IS UNDER THE CHARGE AND CONTROL OF VA. THE POLICY APPLIES TO CIGARETTES, CIGARS, PIPES OR ANY OTHER COMBUSTION OF TOBACCO, INCLUDING BUT NOT LIMITED TO ELECTRONIC OR E-CIGARETTES, VAPE PENS OR E-CIGARS.

UNDER VHA DIRECTIVE 1085, ALL VHA HEALTH CARE FACILITIES WILL BE SMOKE-FREE FOR PATIENTS, VISITORS, CONTRACTORS, VOLUNTEERS AND VENDORS EFFECTIVE OCTOBER 1, 2019.

1. ISOLATE HVAC SYSTEM IN AREA WHERE WORK IS TO BE DONE TO PREVENT CONTAMINATION OF DUCT SYSTEM.

2. MAINTAIN NEGATIVE AIR PRESSURE AT ALL TIMES WITH NO DISRUPTION OF THE AIR SYSTEMS OF THE ADJACENT AREAS. INSTALL HEPA (HIGH EFFICIENCY PARTICULATE ACCUMULATOR) FILTER VACUUM SYSTEM RATED AT 99.97% CAPTURE OF 0.3 MICRONS

(EFFECTIVE FOR POLLEN AND MOLD SPORES).

1. VA DESIGN MANUAL (PG-18-10)

2. VA DESIGN, QUALITY, AND STANDARD ALERTS

3. VA DESIGN GUIDES (PG-18-12)

4. VA DESIGN AND CONSTRUCTION PROCEDURES (PG-18-3)

5. PHYSICAL SECURITY DESIGN MANUAL FOR VA FACILITIES

6. VA FIRE PROTECTION DESIGN MANUAL

7. VA BARRIER FREE DESIGN GUIDE (PG-18-3)

8. VA SIGNAGE DESIGN GUIDE

9. NFPA 101: LIFE SAFETY CODE - LATEST VERSION

10. NFPA 13: STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS

11. NFPA 70: NATIONAL ELECTRICAL CODE

12. ASHRAE 62.1: VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY

13. ASHRAE 90.1: ENERGY STANDARD FOR BUILDINGS

14. VA NATIONAL CAD STANDARD APPLICATION GUIDE

15. NFPA NATIONAL FIRE CODES (EXCEPT NFPA 5000 & 900)

16. VA MASTER SPECIFICATIONS

17. NEC NATIONAL ELECTRICAL CODE - LATEST VERSION

18. VA SUSTAINABLE DESIGN MANUAL

19. INTERNATIONAL BUILDING CODE (IBC) - LATEST VERSION

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date:

CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Architect:

CB DESIGN GROUP, INC.

11720 Beltsville Drive, Suite 350 Calverton, Maryland 20705 443.388.7351 POC: Ken Jones

Consultant:

HF LENZ

1407 SCALP AVENUE

JOHNSTOWN, PA 15904

814-2269-9300

POC: ROBERT MICKLE A R C H I T E C T S E N G I N E E R S

H.F. LENZ COMPANY

1407 Scalp Avenue Johnstown, PA 15904

Phone: 814-269-9300 FAX: 814-269-9301 cadd@hflenz.com www.hflenz.com Engineers - Planners - Surveyors - Energy Consultants Corporal Michael J. Crescenz VAMC

3900 Woodland Ave, Philadelphia, PA 19104

09-20-2021

642-CSI-802

DRKBJ

SITE PREP TO REPLACE CT

SIMULATOR

BID SET

GENERAL NOTES

GI300

-C

S I-

G I3

.p d f

GENERAL NOTESCODES AND REFERENCES

SMOKING POLICY

ENVIRONMENTAL CONTROL NOTES

MEDICAL WASTE NOTES

(APPLY TO ALL SHEETS IN THE ENTIRE SET OF DRAWINGS)

UP

ENGINEERS

OFFICE

B3B111

TOILET

B3B112

STORAGE

ELEVATOR ELEVATOR

ELEVATOR ELEVATOR

ELEVATOR ELEVATOR

STAIR 10

LOUNGE

MALE LOCKER

ROOM

B3B105

PHYSICIAN

WORKROOM

B3B137

SUPPLY

B3B138a

RECORD

REVIEW

ELEVATOR ELEVATOR

FEMALE

LOCKER ROOM

B3B104

FEMALE

LOCKER ROOM

B3B106

LOUNGE

B3B108

MALE LOCKER

ROOM

B3B107CORRIDOR

CB3-14

CORRIDOR

CB3-13

ELEVATOR PIT

WAITING

B3A132

SEC. AND FILES

B3A123

CHIEF

B3A120

OFFICE

B3A119

OFFICE

B3A118

OFFICE

B3A117

ONCOLOGY

B3A115

SERVICE

B3A136

STRETCHER

WAITING

B3A131

COMPUTER

B3A130

ULTRA SOUND

B3A129

STORAGE

B3A133

E.C

B3A134STAIR 9

ELEVATOR

EQUIPMENT

ROOM

B3B110

ELEVATOR

RESEARCH/REGIONAL

OFFICE/MEDICAL/GENERAL

STORAGE

B3B109

STORAGE OFFICE

B3A136a

STORAGE

B3B102

RESIDENT

B3A114

DRESS

B3A113a

DRESS

B3A113

MOLD ROOM

B3A112

TOILET

B3A111

TOILET

B3A110

EXAM

B3A106

EXAM

B3A107

EXAM

B3A108

MULTI-VIEW

B3A109

IV ROOM/DARK

ROOM

B3A126

TOILET

B3A125

CLEAN UTILITY

B3A121

LAB

B3A117

SOILED

UTILITY

B3A122

DRESS

B3A124

CT SIMULATOR

B3A128

RADIOACTIVE

MATERIALS

B3A127a

CHILLER ROOM

B3A127a

EQUIPMENT

B3A127b

FILE ROOM

B3A127

MEDICAL

STORAGE

B3A127c

RADIOACTIVE

MATERIALS

B3A127b

CONTROL ROOM

B3A128a

CORRIDOR

CB3-7

CORRIDOR

CB3-4

CONTROL ROOM

B3A104

MEGAVOLT

B3A103

CORRIDOR

CB3-3

CORRIDOR

CB3-2

CORRIDOR

CB3-9

ELEVATOR

LOBBY

CB3-11

ELEVATOR

LOBBY

CB3-12

CORRIDOR

CB3-15

EQUIPMENT

ROOM

B3A104a

B

C

D

E

F

G

4 8 11 13

14 15 16 17 18 19

7 9 10 12

NA

AD100

F6

LINEAR

ACCELERATOR

B3A105

NORTH

SUB-BASEMENT FLOOR KEY PLAN

AREA OF WORK

BUILDING 2

BUILDING 1

SCOPE OF WORK

LEGEND

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date:

CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Architect:

CB DESIGN GROUP, INC.

11720 Beltsville Drive, Suite 350 Calverton, Maryland 20705 443.388.7351 POC: Ken Jones

Consultant:

HF LENZ

1407 SCALP AVENUE

JOHNSTOWN, PA 15904

814-2269-9300

POC: ROBERT MICKLE A R C H I T E C T S E N G I N E E R S

H.F. LENZ COMPANY

1407 Scalp Avenue Johnstown, PA 15904

Phone: 814-269-9300 FAX: 814-269-9301 cadd@hflenz.com www.hflenz.com Engineers - Planners - Surveyors - Energy Consultants Corporal Michael J. Crescenz VAMC

3900 Woodland Ave, Philadelphia, PA 19104

09-20-2021

642-CSI-802

DRKBJ

SITE PREP TO REPLACE CT

SIMULATOR

BID SET

EXISTING CONDITIONS PLAN

GC200

-C

S I-

G C

.p d f

1/8" = 1'-0"A15 EXISTING SUB-BASEMENT PLAN

NORTH

SUB-BASEMENT KEY PLAN

AREA OF WORK

BUILDING 2

BUILDING 1

EXISTING TRAVEL DISTANCE TO EXIT

EXIT A - 182'

EXIT B - 135'

EXISTING TRAVEL DISTANCE TO EXIT

EXIT A - 195'

EXIT B - 143'

EXIT B

EXIT A

143'

195'

SMOKE PARTITION

1-HOUR PARTITION

2-HOUR PARTITION

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date:

CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Architect:

CB DESIGN GROUP, INC.

11720 Beltsville Drive, Suite 350 Calverton, Maryland 20705 443.388.7351 POC: Ken Jones

Consultant:

HF LENZ

1407 SCALP AVENUE

JOHNSTOWN, PA 15904

814-2269-9300

POC: ROBERT MICKLE A R C H I T E C T S E N G I N E E R S

H.F. LENZ COMPANY

1407 Scalp Avenue Johnstown, PA 15904

Phone: 814-269-9300 FAX: 814-269-9301 cadd@hflenz.com www.hflenz.com Engineers - Planners - Surveyors - Energy Consultants Corporal Michael J. Crescenz VAMC

3900 Woodland Ave, Philadelphia, PA 19104

09-20-2021

642-CSI-802

DRKBJ

SITE PREP TO REPLACE CT

SIMULATOR

BID SET

LIFE SAFETY PLAN

GC201

-C

S I-

G C

.p d f

1/8" = 1'-0"1 FIRE PROTECTION PLAN

EXISTING PATHS OF EGRESS WITHIN THE BUILDING HAVE NOT BEEN MODIFIED FOR THIS PROJECT.

GENERAL NOTES:

1. OCCUPANCY CLASSIFICATION FOR THE FLOOR IS HEALTHCARE

2. TOTAL PROJECT AREA OF RENOVATION: 507 SF

3. CURRENT USE AND OCCUPANCY TYPE REMAINS UNCHANGED FOR THIS PROJECT

4. THE FLOOR IS FULLY SPRINKLERED.

WALL RATING LEGEND:

B

C

"1'

8"

CT SIMULATOR

B3A128

CONTROL ROOM

B3A128A

B

C

REMOVE ICRA BARRIER AND DOORS IN

THEIR ENTIRETY.

PATCH AND REPAIR ALL FINISHES TO

MATCH EXISTING CONDITIONS.

CT SIMULATOR

B3A128

CONTROL ROOM

B3A128A

INFECTION CONTROL RISK ASSESSMENT (ICRA) POLICY

PRECAUTIONS DURING CONSTRUCTION (ALL PHASES)

1. UTILIZE 6-MIL FIRE-RATED POLY PLASTIC SHEET WITH EXPANDABLE POLES TO ISOLATE AREA DURING

CONSTRUCTION OF ICRA PARTITION WITH SECURITY DOOR.

2. EXECUTE WORK BY METHODS TO MINIMIZE CREATING DUST FROM CONSTRUCTION OPERATIONS.

3. ANY CEILING TILES DISPLACED FOR VISUAL INSPECTION MUST BE REMOVED CAREFULLY AND IMMEDIATELY REPLACED. INSTALL NEW CEILING TILE IN ITS PLACE IF IT IS DAMAGED IN THE PROCESS.

4. PROVIDE ACTIVE MEANS TO PREVENT AIRBORNE DUST FROM DISPERSING INTO ATMOSPHERE.

5. WATER MIST WORK SURFACES TO CONTROL DUST WHILE CUTTING GYP. BOARD FOR BARRIERS.

6. BLOCK OFF AND SEAL AIR VENTS IN THE CONSTRUCTION AREA.

7. REMOVE OR ISOLATE HVAC SYSTEM IN AREA WHERE WORK IS BEING DONE TO PREVENT CONTAMINATION

OF DUCT SYSTEM.

8. REMOVE CONSTRUCTION WASTE IN SEALED CONTAINERS DAILY AFTER 4:30 PM.

9. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA FILTER EQUIPPED AIR FILTRATION UNITS. COORDINATE LOCATION OF ABOVE FLOOR PENETRATION TO DISCHARGE AIR WITH THE VA COR.

PATCH FLOOR PENETRATION AFTER CONSTRUCTION AS REQUIRED TO MATCH EXISTING.

10. SEAL HOLES, PIPES, CONDUITS, AND PUNCTURES AIRTIGHT AND/OR FIRE SEAL AS REQUIRED.

11. COORDINATE ALL INFECTION CONTROL RISK ASSESSMENT (ICRA) REQUIREMENTS WITH THE VA INFECTION

CONTROL OFFICER AND VA COR.

12. PROVIDE DIGITALLY RECORDING MONOMETER OUTSIDE OF PERIMETER WALL.

13. UTILIZE ONLY HEPA RATED VACUUMS.

14. PROVIDE DUST STICKY MATS AT EACH ENTRANCE / EXIT. CHANGE STICKY MATS EVERY 4 HOURS.

4"

SEAL W/ FIRE CAULK, CONT.

EXISTING STRUCTURAL DECK

EXISTING WALL FRAMING

2 LAYERS 5/8" TYPE X GYP BOARD

2ND LAYER OF GYP BOARD TO

OVERLAP EXISTING FINISHED WALL

EXISTING SPACE NEW WORK SIDE

SEAL W/ FIRE CAULK, CONT.

NEW ACOUSTIC CEILING TILE

EXISTING FINISHED WALL

EXISTING ACOUSTIC CEILING TILE

NOTE:

CRITICAL BARRIERS ARE THE EXTENSION OF EXISTING WALLS UP TO

THE EXISTING DECK ABOVE. THE PERIMETER WALLS OF EACH PHASE

MUST EXTEND UP TO THE EXISTING DECK, ABOVE. IF THEY DO NOT,

THE CONTRACTOR IS TO EXTEND THE WALLS UP TO THE EXISTING

DECK. CONTRACTOR MUST ENSURE THAT ALL PENETRATIONS HAVE

BEEN FIRE STOPPED.

NORTH

SUB-BASEMENT FLOOR KEY PLAN

AREA OF WORK

BUILDING 2

BUILDING 1

GENERAL INFECTION CONTROL NOTES

INFECTIOUS CONTROL PROCEDURES (ICRA)

NOTE:

CONTRACTOR MUST PROTECT DEMOLITION AND CONSTRUCTION ACTIVITIES IN ACCORDANCE WITH THE

FOLLOWING PROVISIONS:

TYPE OF CONSTRUCTION ACTIVITY: CLASS IV, TYPE D.

DURING CONSTRUCTION OF PROJECT:

01. CONTRACTOR SHALL FOLLOW VA/ ICRA REGULATIONS IN PERFORMING ALL WORK.

02. CONTRACTOR SHALL COORDINATE WITH THE VA FOR OFF-HOURS ACCESS TO THE FLOORS ABOVE AND BELOW THE WORK NEEDED FOR MEP TIE-INS. TEMPORARY ICRA BARRIERS ARE TO BE INSTALLED

AROUND ALL WORK AREAS PRIOR TO CONSTRUCTION.

03. CONTRACTOR SHALL FOLLOW ALL FIRE SAFETY CODES DURING CONSTRUCTION.

04. CONTRACTOR SHALL PROVIDE THE VA TWO (2) WEEKS (14 CALENDAR DAYS) NOTICE PRIOR TO ANY SYSTEM

SHUTDOWN WORK VIA A SHUTDOWN REQUEST FORM, (FORM TO BE PROVIDED BY THE VA).

05. BEFORE COMMENCEMENT OF CONSTRUCTION, COORDINATE THE ICRA PROCEDURE WITH THE COR AND THE FACILITY INFECTION CONTROL DEPARTMENT. CONTRACTOR MUST ACQUIRE AN ICRA PERMIT FROM INFECTION CONTROL DEPARTMENT PRIOR TO THE START OF CRITICAL BARRIER AND ICRA BARRIER

CONSTRUCTION.

06. COORDINATE WITH THE VA COR FOR ANY PHASING PLAN REQUIREMENTS TO SCHEDULE SHUTDOWNS, TEMPORARY RELOCATION OR CLOSED DOWN AREAS THAT MAY BE AFFECTED DUE TO THE RENOVATION OF

THE SCHEDULED PROJECT.

07. ALL CRITICAL BARRIER AND ICRA BARRIER WORK TO BE COMPLETED ON SECOND SHIFT FROM 4:30PM - 11PM MONDAY - FRIDAY OR ON SATURDAYS AND SUNDAYS. (WHEN AVAILABLE, PER RADIATION THERAPY

SCHEDULE.) ALL WEEKEND WORK MUST BE APPROVED BY THE COR.

08. REMOVE OR ISOLATE HVAC SYSTEM IN AREA WHERE WORK IS BEING DONE TO PREVENT CONTAMINATION OF DUCT SYSTEM, PRIOR TO ANY PHASE WORK COMMENCEMENT. HVAC SYSTEM ISOLATION MATERIALS TO BE REMOVED IN THEIR ENTIRETY, PRIOR TO TURNING THE SPACE OVER TO THE VA FACILITY AFTER EACH

PHASE'S COMPLETION OF WORK.

09. COMPLETE ALL CRITICAL BARRIERS TO 1-HOUR FIRE-RATING I.E. GYP BOARD, PLYWOOD, PLASTIC , TO SEAL AREA FROM NON-WORK AREA, BEFORE CONSTRUCTION BEGINS. CRITICAL BARRIERS ARE THE EXTENSION OF EXISTING WALLS TO THE UNDERSIDE OF THE DECK ABOVE AND ARE TO BE SEALED WITH FIRE SEALANT AT THE DECK/ TOP OF WALL INTERSECTION AND AROUND ALL GAPS FROM WALL PENETRATIONS OF EXISTING ITEMS (PIPES, CONDUIT, DUCTWORK, ETC.) THAT THE CRITICAL BARRIERS MUST BE BUILT

AROUND.

10. WHEN CONSTRUCTING ICRA ANTE-ROOMS, REMOVE AND SECURELY STORE ALL INTERFERING WALL APPURTENANCES, INCLUDING BUT NOT LIMITED TO HANDRAILS AND ELECTRICAL DEVICES. ALL ITEMS TO

BE SECURELY STORED FOR REINSTALLATION BY THE CONTRACTOR.

11. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA EQUIPPED AIR FILTRATION UNITS, CONTRACTORS SHALL MAINTAIN 0.001" NEGATIVE PRESSURE. PROVIDE DIGITALLY RECORDING GAUGE MOUNTED ON THE OUTSIDE OF THE PERIMETER WALL OF THE PROJECTS WORKSPACE. CONTRACTOR TO

CHECK GAUGE DAILY.

12. SEAL ALL HOLES, PIPES, CONDUITS, AND PENETRATIONS IN THE WALLS ABOVE THE CEILING.

13. CONSTRUCT ANTE-ROOM AND PROVIDE WALK-OFF STICKY MATS. REQUIRE ALL PERSONNEL TO PASS THROUGH THIS ROOM SO THEY CAN HEPA VACUUM CLEAN THEMSELVES BEFORE LEAVING WORK SITE OR THEY SHALL WEAR CLOTH OR PAPER COVERALLS THAT ARE REMOVED EACH TIME THEY LEAVE THE WORK

SITE.

14. ALL PERSONNEL EXITING WORK SITE ARE REQUIRED TO WEAR SHOE COVERS. SHOE COVERS MUST BE

CHANGED EACH TIME WORKERS EXIT THE WORK AREA.

15. REPORT TOTAL WEIGHT OF CONSTRUCTION WASTE DISPOSED OF TO THE COR AND CONTRACTING

OFFICER ON THE LAST DAY OF EACH MONTH.

16. COVER TRANSPORT RECEPTACLES OR CART. TAPE COVERING SECURELY UNLESS UTILIZING A SOLID LID.

17. CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF SMOKE COMPARTMENTS WITHIN AREA OF

CONSTRUCTION DURING THE ENTIRE PROJECT.

18. COORDINATE A DISCHARGE PLAN FOR EACH PHASE WITH THE VA PRIOR TO COMMENCING WORK ON THE

NEXT PHASE.

19. HEPA FILTER UNIT DISCHARGE DUCT MUST LEAVE THE ICRA CONTAINMENT AREA TO BE DISCHARGED TO THE OUTSIDE. THE DUCT SHALL BE SHEET METAL WHEN CROSSING THE ICRA BARRIER TO THE POINT OF DISCHARGE. A PLAN SHALL BE SUBMITTED AND REVIEWED WITH THE VA COR FOR OCCUPIED AREAS THAT THE DISCHARGE DUCT MUST TRAVERSE. FLEX DUCT IS PERMITTED INSIDE THE ICRA BARRIER AND OTHER LOCATIONS AS APPROVED BY THE VA. CONNECTIONS TO THE OUTSIDE DISCHARGE POINT (I.E. WINDOW) SHALL BE MADE WITH SHEET METAL AND SHALL BE SECURE. CONNECTIONS SHALL NOT BE MADE WITH

DUCT TAPE.

20. ANY MEP WORK OUTSIDE THE ICRA BARRIER MAY NOT REQUIRE FULL BARRIER WALL PROTECTION. LESS STRINGENT MEASURES SUCH AS PLASTIC SHEETING SHALL BE PERMITTED, AS APPROVED BY VA COR FOR AREAS WITH SHORT TERM WORK. THE WORK IN THESE AREAS IS EXPECTED TO BE COMPLETE OR DONE IN

SECTIONS THAT COMPLETE WORK AND RESTORE THE SPACE IN A ONE DAY WORK SHIFT.

21. CONTRACTOR SHALL COORDINATE FINAL ICRA WALLS WITH VA COR AND PROTECT EXISTING WALL

MOUNTED EQUIPMENT IDENTIFIED TO REMAIN.

22. RELOCATE EXISTING "EXIT" SIGNS TO LOCATIONS AS SHOWN ON ELECTRICAL DRAWINGS TO PROVIDE

CLEAR EGRESS PATH DIRECTIONS DURING CONSTRUCTION.

23. CONTRACTOR SHALL PROTECT ALL EXISTING FINISHES THAT ARE TO REMAIN.

UPON COMPLETION OF EACH PHASE

1. DO NOT REMOVE ICRA/ANTE ROOM BARRIERS FROM WORK AREA UNTIL THE PHASE WORK IS INSPECTED

AND APPROVED, IN WRITING, BY VA COR.

2. REMOVE BARRIER MATERIAL CAREFULLY TO MINIMIZE SPREADING OF DIRT AND DEBRIS ASSOCIATED WITH CONSTRUCTION. UTILIZE POLYURETHANE PLASTIC SHEETING DURING INSTALLATION AND DEMOLITION OF

ICRA BARRIERS TO CONTAIN DUST AND DEBRIS.

3. CONTRACTOR'S FINAL CLEANUP THROUGHOUT PHASE WORK AREA SHALL UTILIZE HEPA FILTERED VACUUMS. PHASE WORK AREA SHALL NOT BE TURNED OVER TO THE VA FOR USE UNTIL IT IS THOROUGHLY CLEANED BY THE VA'S ENVIRONMENTAL SERVICES (EMS). PROVIDE THE VA COR WITH ONE (1) WEEK

NOTIFICATION PRIOR TO THE EMS CLEANING TO ALLOW FOR SCHEDULING OF EMS.

EXISTING ROOF OR FLOOR.

6 MIL FIRE RETARDANT POLY.

EXTEND TO TO UNDERSIDE OF

STRUCTURE ABOVE.

TAPEAND SEAL AT ALL EDGES AND

AROUND ALL PENETRATIONS.

EXISTING CONC. FLOOR.

INFECTION CONTROL KEYNOTES

PRECAUTIONS DURING CONSTRUCTION (ALL PHASES)

01 INFECTION CONTROL BARRIER PAINTED TO MATCH EXISTING CORRIDOR WALLS.

02 REMOVE EXISTING SPRINKLER IN HALLWAY IN PREPARATION FOR NEW ANTEROOM. SPRINKLER TO BE

REINSTALLED AFTER ICRA REMOVAL. PROVIDE A TEMPORARY LIGHT FIXTURE IN ANTEROOM.

03 CONTRACTOR TO REMOVE AND PROTECT ROOM SIGNAGE PRIOR TO CONSTRUCTION. SIGNAGE TO BE

REINSTALLED AT THE END OF CONSTRUCTION.

04 PROVIDE 45 MIN RATED DOOR ASSEMBLY WITH CLOSER AND A VA COMPATIBLE 7-PIN INTERCHANGEABLE CORE STOREROOM FUNCTION CYLINDRICAL LOCK WITH PUSHBUTTON CODE LOCK FOR ACCESS. BASIS OF DESIGN IS STANLEY 9K SERIES LOCK. PROVIDE SIGN ON OCCUPIED SIDE OF DOOR THAT STATES

"CONSTRUCTION AREA. AUTHORIZED PERSONNEL ONLY."

SECTION

PLAN

7/

8"

3 5/8" METAL STUDS @ 16" OC, TYP

5/8" GWB, BOTH SIDES, SEE ROOM FINISH

SCHEDULE FOR FINISHES

CONTINUOUS METAL STUD TOP TRACK

CONTINUOUS METAL STUD BOTTOM

TRACK

LINE OF FINISHED FLOOR, SEE ROOM

FINISH SCHEDULE FOR FLOOR & BASE

TYPE

LINE OF EXISTING SOFFIT/WALL.

CONTINUE STUD WALL AND GWB TO

BOTTOM OF DECK WHERE REQUIRED.

CONTRACTOR TO VERIFY EXISTING CONDITIONS.

CONTINUOUS METAL HORIZONTAL

BRIDGING CHANNEL @ MID HEIGHT, TYP

FIRE-RATED SEALANT, BOTH SIDES

3 5/8" METAL STUDS @ 16" OC, 25-GAGE,

TYPICAL

5/8" TYPE "X" GWB, BOTH SIDES, STAGGER

JOINTS ON OPPOSITE SIDES OF ROOM SEE

ROOM FINISH SCHEDULE FOR FINISHES

EXISTING FINISHED CEILING

SYSTEM

PRIOR TO DEMOLISHING IN AN AREA,

DISCONNECT AND REMOVE EXISTING HVAC,

DUCTS, ELECTRICAL AND PLUMBING LINES.

SEE MEP DRAWINGS.

1-HR RATED PARTITION - U465

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date:

CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Architect:

CB DESIGN GROUP, INC.

11720 Beltsville Drive, Suite 350 Calverton, Maryland 20705 443.388.7351 POC: Ken Jones

Consultant:

HF LENZ

1407 SCALP AVENUE

JOHNSTOWN, PA 15904

814-2269-9300

POC: ROBERT MICKLE A R C H I T E C T S E N G I N E E R S

H.F. LENZ COMPANY

1407 Scalp Avenue Johnstown, PA 15904

Phone: 814-269-9300 FAX: 814-269-9301 cadd@hflenz.com www.hflenz.com Engineers - Planners - Surveyors - Energy Consultants Corporal Michael J. Crescenz VAMC

3900 Woodland Ave, Philadelphia, PA 19104

09-20-2021

642-CSI-802

DRKBJ

SITE PREP TO REPLACE CT

SIMULATOR

BID SET

PHASING PLANS - ICRA

GC300

-C

S I-

G C

.p d f

1/4" = 1'-0"G9 PLAN - ICRA CONSTRUCTION

1/4" = 1'-0"B9 PLAN - ICRA DEMOLITION

3/4" = 1'-0"H12 CRITICAL BARRIER - (TYP. ABOVE CEILING WALL INFILL DETAIL)

3/4" = 1'-0"A15 6 MIL POLY ICRA BARRIER

1 1/2" = 1'-0"G15 ICRA BARRIER DETAIL w/ GWB CEILING

NORTH

NORTH

WORK SHOULD BE COMPLETED 100 DAYS FROM NTP. CONSTRUCTION CAN BE SCHEDULED FOR 1ST

SHIFT, 2ND SHIFT AND WEEKENDS TO MEET THE TIMELINE.

(SEE G15 THIS SHEET).

CT SIMULATOR

B3A128

CONTROL ROOM

B3A128a

CORRIDOR

CB3-7

1/8" Pb EQUIVALENT TO 14'-0" A.F.F.

1/8" Pb EQUIVALENT TO 14'-0" A.F.F.

1/ 8"

P b

E Q

U

IV

A

LE

N T

TO

4' -0

A

.F .F

1/ 8"

P b

E Q

U

IV

A

LE

N T

TO

4' -0

A

.F .F

L3

L3L2

L1

L1

L1 MIN. 1/8" Pb

EQUIVALENT CEILING

NORTH

SUB-BASEMENT FLOOR KEY PLAN

AREA OF WORK

BUILDING 2

BUILDING 1

LEAD SHIELDING KEYNOTES

L1. LEAD-LINED WALL WITH EQUIVALENT THICKNESS OF 1/8" FROM

FLOOR TO 14'-0" A.F.F.

L2. LEAD-LINED WINDOW AND FRAME WITH EQUIVALENT THICKNESS OF

1/8".

L3. LEAD-SHIELDED DOOR AND FRAME WITH EQUIVALENT THICKNESS

OF 1/8".

1. REFER TO SHIELDING DESIGN EVALUATION (DATED 2/2/21) AND

SHIELDING INTEGRITY SURVEY (DATED 2/12/21) PROVIDED BY WEST

PHYSICS. CONTRACTOR MUST MAINTAIN OR EXCEED ALL MINIMUM

REQUIRED LEAD SHIELDING THICKNESSES AND EQUIVALENCIES AS

IDENTIFIED WITHIN THE RADIATION SHIELDING DESIGN

EVALUATION.

2. SHIELDING CONTRACTOR SHALL PROVIDE AND SUBMIT SHOP

DRAWINGS REVIEWED AND SEALED BY A PROFESSIONAL ENGINEER

FOR APPROVAL BY PROJECT COR.

3. SUPPLY AND INSTALLATION OF ALL SHIELDING MATERIALS

INCLUDING BUT NOT LIMITED TO LEAD LINED GWB, STEEL

RESTRAINTS, AND STEEL SUPPORT COMPONENTS SHALL BE THE

SOLE RESPONSIBILITY OF SHIELDING VENDOR/INSTALLER.

4. WHERE Pb SHIELDING EQUIVALENT THICKNESS IS CALLED OUT AT 1/8" OR LESS. IT IS ASSUMED THAT Pb LINED GYPSUM WALL BOARD

WILL BE USED AS THE SHIELDING MATERIAL. LEAD SHIELDING IN

CEILING SHALL BE LEAD-LINED PLYWOOD.

5. ALL SHOP DRAWINGS AND SHIELDING SUBMISSIONS SHALL BE

REVIEWED BY THE VA FOR APPROVAL.

6. ANY SUPPORT STRUCTURE OR FRAMING UTILIZED TO SUPPORT

LEAD SHIELDING SHALL NOT INTERRUPT EXISTING FIREPROOFING.

ALL FIREPROOFING THAT IS DISTURBED SHALL BE REPLACED IN

ACCORDANCE WITH ALL APPLICABLE CODES.

7. THERE SHALL BE NO HOLES, GAPS OR INCONSISTENCIES IN THE

SHIELDING MATERIAL OR ITS EQUIVALENCY. ALL SEAMS BETWEEN

NEW AND EXISTING SHIELDING MATERIALS SHALL BE COVERED

WITH A MIN 2" LEAD STRIP THE ENTIRE LENGTH OF SEAM.

8. SECURE ALL STRUCTURAL METAL STUDS TO SHIELDING RESTRAINT

STEEL AND / OR STRUCTURE ABOVE.

9. CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY BREACHES IN

SHIELDING WHETHER NEW OR EXISTING.

10. LEAD SHIELDING SHOULD BE TESTED AND APPROVED BY VA

RADIATION SAFETY OFFICER.

11. EXTEND LEAD WALLS TO THE CEILING LEAD.

LEAD SHIELDING GENERAL NOTES

FOLD LEAD SHIELDING OVER

CABINET ATTACHMENT AS

SHOWN AND AFFIX WITH

ADHESIVE

5/8" GWB WITH 1/8"

LEAD SHIELDING

CABINET /

ACCESSORY

METAL STRAPPING

AS REQUIRED

LEAD SHIELDING

PROTECTION CAP

INFILL WITH

CONCRETE

EXISTING RACEWAY,

VERIFY SIZE IN FIELD

LINE OF EXISTING

CONCRETE FLOOR

4x LARGEST

DIMENSION OF

DUCT

NOTE: ALL PENETRATIONS

AT LEAD WALLS TO BE

SHIELDED

LEAD SHIELDING EQUAL TO LEAD

SHIELDING REQUIRED FOR WALL. WRAP

AROUND ALL SIDES OF DUCT WITH 2"

LAPS AS REQUIRED

LA

R

G E

S T

D

IM

E N

S

IO

N O

F D

U C

T

SHIELDED ROOM

SIDE

4x LARGEST

DIMENSION OF

DUCT

LEAD-LINED GWB

2"

LEAD SHIELDING EQUAL TO LEAD

SHIELDING REQUIRED FOR WALL. WRAP

AROUND ALL SIDES OF DUCT WITH 2"

LAPS AS REQUIRED

2" MIN.

4"

4"

EXISTING WALL WITH LEAD SHIELDING

TO REMAIN

PROVIDE AND INSTALL 1/8" LEAD 4"x4" "FLASHING"

AT BASE OF WALL. PROVIDE 4" MIN OVERLAP UNDER

NEW FLOOR LEAD AND BEHIND EXISTING LEAD GWB

FLOOR AND BASE AS SCHEDULED: SEE FINISH SCHEDULE.

NEW 1/4" SUB-FLOOR, FIELD VERIFY THICKNESS TO MATCH

EXISTING CONDITIONS. FULLY ADHERE OVER LEAD SHIELDING

WHERE MECHANICAL FASTENERS ARE REQUIRED,

COUNTERSINK AND PROVIDE SUPPLEMENTAL LEAD

PROTECTION AT ALL PENETRATIONS

SHIELDED ROOM

SIDE

NEW 1/8" THICK

LEAD WITH 2" WIDE

OVERLAP LEAD

SHIELDING IN WALL

5/8" GWB WITH 1/8"

LEAD SHIELDING

5/8" GWB WITH 1/8"

LEAD SHIELDING

2"

2"

SHIELDED ROOM

SIDE

EXISTING LEAD-LINED GWB PARTITION

NEW LEAD SHIELDING WITH 2"

WIDE OVERLAP. LEAD SHIELDING

EQUAL TO THICKNESS IN WALL.

EXISTING IN-WALL MOUNTED

DEVICE REMOVED FROM WALL,

OPENING VARIES. REFER TO DEMO

DRAWINGS

NEW 5/8"GWB W/ LEAD SHIELDING.

LEAD SHIELDING EQUAL TO

THICKNESS OF LEAD IN WALL.

NEW LEAD SHIELDING WITH 2"

WIDE OVERLAP. LEAD SHIELDING

EQUAL TO THICKNESS IN WALL.

2" O

P E

N

IN

G V

A R

IE

S

2"2" V

A R

IE

S

2"

2" VARIES 2"

OPENING

ELEVATION SECTION

SHIELDED

ROOM SIDE

ELEVATION SECTION

SHIELDED

ROOM SIDE

LEAD-LINED GWB

NEW LEAD SHIELDING WITH 2" WIDE

OVERLAP. NEW LEAD SHIELDING

EQUAL TO THICKNESS IN WALL

NEW IN-WALL MOUNTED DEVICE,

AS REQUIRED BY ARCH/MEP/EQUIP

DRAWINGS

NEW LEAD SHIELDING AROUND ALL

SIDES OF BOX/OPENING. LEAD

SHIELDING EQUAL TO THICKNESS

OF LEAD IN WALL

NEW LEAD SHIELDING WITH 2" WIDE

OVERLAP. NEW LEAD SHIELDING

EQUAL TO THICKNESS IN WALL

2"

V A

R

IE

S

O P

E N

IN

G

2"

PIPE

4x P

IP

E

D

IA

P

IP

E

LEAD SHIELDING EQUAL TO

THICKNESS IN WALL. WRAP

AROUND CIRCUMFERENCE

OF PIPE.

PIPE OR CONDUIT

LEAD-LINED GWB

SHIELDED ROOM

SIDE

4x PIPE DIAMETER

1/8" THICK LEAD WRAP

AROUND CIRCUMFERENCE OF

PIPE. OVERLAP NEW LEAD 2".

8" MIN.

1/8" THICK LEAD WRAP AROUND

CIRCUMFERENCE OF PIPE. OVERLAP NEW

LEAD 2" OVER EXISTING LEAD ON FLOOR.

PIPE, SIZE VARIES

O F

P

IP

E

4x D

IA

GALVANIZED IRON SLEEVE

C O

N

S

LA

V

A R

IE

S

CLAMP

O F

P

IP

E

4x D

IA

EXISTING FLOOR ABOVE

PLYWOOD W/ 1/8" LEAD SHIELDING

INSTALLED AS HIGH AS POSSIBLE.

COORDINATE WITH ALL OTHER TRADES.

NEW 1/16" LEAD SHIELDING

W/ 2" WIDE OVERLAP

EXISTING STRUCTURE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date:

CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Architect:

CB DESIGN GROUP, INC.

11720 Beltsville Drive, Suite 350 Calverton, Maryland 20705 443.388.7351 POC: Ken Jones

Consultant:

HF LENZ

1407 SCALP AVENUE

JOHNSTOWN, PA 15904

814-2269-9300

POC: ROBERT MICKLE A R C H I T E C T S E N G I N E E R S

H.F. LENZ COMPANY

1407 Scalp Avenue Johnstown, PA 15904

Phone: 814-269-9300 FAX: 814-269-9301 cadd@hflenz.com www.hflenz.com Engineers - Planners - Surveyors - Energy Consultants Corporal Michael J. Crescenz VAMC

3900 Woodland Ave, Philadelphia, PA 19104

09-20-2021

642-CSI-802

DRKBJ

SITE PREP TO REPLACE CT

SIMULATOR

BID SET

LEAD SHIELDING PLANS

GC400

-C

S I-

G C

.p d f

1/4" = 1'-0"G5 EXISTING LEAD SHIELDING PLAN

3" = 1'-0"D14 LEAD DETAIL - CABINET / ACCESSORY WALL ATTACHMENT - PLAN DETAIL

3" = 1'-0"A8 LEAD DETAIL - CABLE RACEWAY

3" = 1'-0"G9 LEAD DETAIL - DUCT SECTION

3" = 1'-0"A14 LEAD DETAIL - FLOOR / WALL

3" = 1'-0"D11 LEAD DETAIL - GWB CORNER

3" = 1'-0"D5 LEAD DETAIL - INFILL OPENING

3" = 1'-0"A5 LEAD DETAIL - NEW DEVICE

3" = 1'-0"A11 LEAD DETAIL - PIPE

3" = 1'-0"D8 LEAD DETAIL - PIPE FLOOR

1 1/2" = 1'-0"F15 LEAD DETAIL - CEILING DETAIL

2X2 ACOUSTIC CEILING TILE SYSTEM.

GYPSUM BOARD CEILING

REMOVE 2X4 LIGHT FIXTURE

NOTE: SPOT ELEVATION SUFFIX "C.H." INDICATES FLAT CEILING HEIGHT ABOVE FINISH FLOOR. SUFFIX "L.P." AND "H.P."

INDICATE LOW POINT AND HIGH POINT OF SLOPED CEILING. WHERE ADJACENT, TRANSITION BETWEEN FLAT AND SLOPED CEILINGS SHALL UTILIZE APPROVED PRE-FINISHED ALUMINUM TRANSITION STRIP. REFER TO SPECIFICATIONS.

REMOVE DIFFUSER

RCP LEGEND

TRACK LIGHT - SEE ELEC

RECESSED

DOWNLIGHT - SEE ELEC

1'X4' RECESSED LIGHT

FIXTURE - SEE ELEC

2'X4' RECESSED LIGHT

FIXTURE - SEE ELEC

1'X4' LIGHT

FIXTURE - SEE ELEC

SPRINKLER

SUPPLY DIFFUSER, REGISTER,

OR GRILL - SEE MECH

RETURN DIFFUSER, REGISTER,

OR GRILL - SEE MECH

REMOVE AIR RETURN

REMOVE 2X2 ACT

RCP NOTES

GENERAL NOTE APPLICABLE TO ALL DRAWINGS - ITEMS AND CONDITIONS DETAILED NOTED OR

OTHERWISE IDENTIFIED ON ONE OF THE SECTIONS OR DETAILS ARE APPLICABLE AND BINDING TO ALL

OTHER SECTIONS AND DETAILS FOR IDENTICAL OR SIMILAR CONDITIONS.

1. REFER TO MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ITEMS NOT SHOWN ON

CEILING PLAN. GRILLES, SPEAKERS, SPRINKLERS, HEAT & SMOKE DETECTORS, TO BE CENTERED

IN TILES UNLESS NOTED OTHERWISE.

B

C

AD100

H15

H9

H11

H13

CT SIMULATOR

B3A128

AD100

F15

F12

F11

F8

CONTROL ROOM

B3A128a

B3A128A

B3A128

C B

-7

EQ02 EQ03

EQ04

EQ16

EQ15

EQ01

EQ12

EQ10

B3636

EQ05

EQ14

B3642

EQ06

C3624

CT025

EQ11

EQ05

CT024

EQ04EQ03

EQ02

EXISTING WALL

WIRE SHELF

EQ16 EQ15

EQ14

EQ06

B3636

EQ05

EQ01

EQ09

EQ10

EQ-11

3'

0" 2'

0"

2'

0"

7'

0" EQ12

EQ07

EQ08

FURR DOWN

3' - 0"

3'

2"

3'

4"

EQ02

WALL MTD SHELF (6 SHELVES)

EQ11

EQ05

C3624

REMOVE BASE CABINET

B3642

ADJ.

ADJ.

EXISTING METAL

BLINDS

ADJUSTABLE SHELVES

WITH BRACKETS

CHASE

REMOVE EXISTING WALL PROTECTION

ADJUSTABLE

SHELVES WITH

BRACKETS

B

C

10' - 0"

CT SIMULATOR

B3A128

CONTROL ROOM

B3A128A

GENERAL DEMOLITION NOTES (ALL PHASES)

1. SCOPE OF DEMOLITION WORK IS NOT LIMITED TO WORK SHOWN ON DEMOLITION

DRAWINGS. CONTRACTOR TO COORDINATE DEMOLITION WITH NEW WORK AND PATCH

EXISTING TO RECEIVE NEW FINISHES.

2. REFER TO MECHANICAL, ELECTRICAL & PLUMBING DRAWINGS FOR DEMOLITION WORK.

WHERE SUCH WORK OCCURS, ARCHITECTURAL ITEMS OR FINISHES SHALL BE REMOVED

ONLY TO THE EXTENT REQUIRED & PATCHED TO MATCH EXISTING ADJACENT

CONSTRUCTION AND FINISHES.

3. REMOVE ALL INTERIOR DOORS, FRAMES AND HARDWARE INDICATED AS DASHED LINES.

4. REMOVE EXISTING CEILING IN ALL AREAS TO RECEIVE A NEW CEILING AND REPLACE ANY

OBSERVED ABOVE-CEILING ICRA VIOLATIONS TO THE COR.

5. REMOVE EXISTING FLOOR FINISH, BASE AND ADHESIVE IN ALL AREAS WHICH ARE TO

RECEIVE NEW FLOOR FINISHES. SEE FINISHES PLAN.

6. PROTECT EXISTING FINISHED WORK & EQUIPMENT WHICH IS TO REMAIN IN AREAS OF

DEMOLITION WORK.

7. REMOVE PARTITIONS SHOWN DASHED.

8. VERIFY EXISTING FIRE PROTECTION ON ALL STRUCTURAL ELEMENTS IN AREA OF WORK

PRIOR TO INSTALLING NEW WORK. PATCH AND REPAIR AS NECESSARY TO MAINTAIN

REQUIRED RATING.

9. AFTER THE REMOVAL OF ICRA WALLS, CLEAN AND PATCH ALL EXISTING SURFACES

AFFECTED BY CONSTRUCTION AND MATCH EXISTING FINISHES.

NORTH

SUB-BASEMENT FLOOR KEY PLAN

AREA OF WORK

BUILDING 2

BUILDING 1

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date:

CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Architect:

CB DESIGN GROUP, INC.

11720 Beltsville Drive, Suite 350 Calverton, Maryland 20705 443.388.7351 POC: Ken Jones

Consultant:

HF LENZ

1407 SCALP AVENUE

JOHNSTOWN, PA 15904

814-2269-9300

POC: ROBERT MICKLE A R C H I T E C T S E N G I N E E R S

H.F. LENZ COMPANY

1407 Scalp Avenue Johnstown, PA 15904

Phone: 814-269-9300 FAX: 814-269-9301 cadd@hflenz.com www.hflenz.com Engineers - Planners - Surveyors - Energy Consultants Corporal Michael J. Crescenz VAMC

3900 Woodland Ave, Philadelphia, PA 19104

09-20-2021

642-CSI-802

DRKBJ

SITE PREP TO REPLACE CT

SIMULATOR

BID SET

DEMOLITION PLAN

AD100

-C

S I-

A D

.p d f

1/4" = 1'-0"F6 EXISTING PLAN

1/4" = 1'-0"H15 EXISTING CT SIMULATOR - NORTH

1/4" = 1'-0"H13 CT SIMULATOR - EAST

1/4" = 1'-0"H11 CT SIMULATOR - SOUTH

1/4" = 1'-0"H9 CT SIMULATOR - WEST

1/4" = 1'-0"F15 CONTROL ROOM - NORTH

1/4" = 1'-0"F12 CONTROL ROOM - EAST

1/4" = 1'-0"F11 CONTROL ROOM - SOUTH

1/4" = 1'-0"F8 CONTROL ROOM - WEST

1/4" = 1'-0"A6 EXISTING REFLECTED CEILING PLAN - DEMO

EXISTING EQUIPMENT

ITEM DESCRIPTION Comments

B3636 BASE CABINET 36"W x 36" H REMOVE

B3642 BASE CABINET 36"W x 42" H REMOVE

C3624 WALL CABINET 36"W x 24" H REMOVE

CT024 25" DEEP COUNTERTOP REMOVE

CT025 25" DEEP COUNTERTOP w/ SINK REMOVE

EQ01 CT SIMULATOR SALVAGE TO SIEMENS

EQ02 POWER DISTRIBUTION UNIT SALVAGE TO SIEMENS

EQ03 SUPPLY CART SALVAGE / REINSTALL

EQ04 BLANKET WARMER SALVAGE / REINSTALL

EQ05 MEDICAL SHARPS DISPOSAL REMOVE

EQ06 HAMPER SALVAGE / REINSTALL

EQ07 PAPER TOWEL DISPENSER REMOVE

EQ08 SOAP DISPENSER REMOVE

EQ09 CAMERA SALVAGE / REINSTALL

EQ10 WIPES REMOVE

EQ11 WALL-MOUNTED SHELF SALVAGE / REINSTALL

EQ12 WATER BATH SALVAGE / REINSTALL

EQ14 UTILITY WIRE SHELF SALVAGE / REINSTALL

EQ15 ROLLING CART SALVAGE / REINSTALL

EQ16 ROLLING CART SALVAGE / REINSTALL

WALL CABINETS TO REMAIN

SUB-BASEMENT FLOOR KEY PLAN

AREA OF WORK

BUILDING 2

BUILDING 1

B B

C C

EQ17

B3A128

B3A128A

C B

-7

CT SIMULATOR

ORIENTATION POINT

C3624

CT025

C3624

B3636

B3636

B3636

C3624C3624

B3636

CT024

CT030

7'

0"

7' - 0"

EQ03

EQ06

EQ05

EQ05

EQ11

EQ04

EQ15

EQ16

EQ14

EQ08 EQ19

EQ18

EQ12

EQ10

AE100

H11

H9

H15

H13

AE100

F15

F8 F12

F11

CT024

CT SIMULATOR

B3A128

CONTROL ROOM

B3A128A

CORRIDOR

CB3-7

EXTENT OF NEW FINISHES IN CORRIDOR CB3-7

VERTICAL TRANSITION STRIP

8' - 6"

WORKSTATION PROVIDED BY SIEMENS.

COORDINATE WITH MANUFACTURER.

EQ17

EQ03 EQ16

EQ04

EQ15

EQ14

P-1 C3624C3624

CT024

EQ06B3636B3636

EQ04

EQ16

EQ05

EQ14

P-1 P-1

EXISTING LEAD-SHIELDED

WINDOW TO REMAIN

EQ19

EQ08

EQ12

B3636

C3624 P-1

EQ12

EQ05

EQ11

C3624 C3624

EQ19

B3636

CT025

B3636 EQ03

P-4

CT030

CT024

EXISTING WALL CABINETS

NEW BLINDS

P-2

CT024

EXISTING WALL CABINETS

P-1

CT024

EXISTING WALL CABINETS

P-1

WP-1

3'

0"

CT030

P-2

B B

C C

10' - 0"

A.F.F.

2' x 2' AT-1

10' - 0"

7' - 0"

7'

0"

2' - 0"

8"

CT SIMULATOR

ORIENTATION POINT

CORRIDOR

CB3-7

CT SIMULATOR

B3A128

CONTROL ROOM

B3A128A

2x2 CEILING SYSTEM. SEE FINISH

SCHEDULE

2x4 CEILING SYSTEM. SEE FINISH

SCHEDULE

GYPSUM BOARD CEILING

NOTE: SPOT ELEVATION SUFFIX "C.H." INDICATES FLAT CEILING HEIGHT ABOVE FINISH FLOOR. SUFFIX "L.P." AND "H.P."

INDICATE LOW POINT AND HIGH POINT OF SLOPED CEILING. WHERE ADJACENT, TRANSITION BETWEEN FLAT AND SLOPED CEILINGS SHALL UTILIZE APPROVED PRE-FINISHED ALUMINUM TRANSITION STRIP. REFER TO SPECIFICATIONS.

TRACK LIGHT - SEE ELEC

RECESSED

DOWNLIGHT - SEE ELEC

1'X4' RECESSED LIGHT

FIXTURE - SEE ELEC

2'X4' RECESSED LIGHT

FIXTURE - SEE ELEC

1'X4' LIGHT

FIXTURE - SEE ELEC

SPRINKLER - SEE PLUMB

SUPPLY DIFFUSER, REGISTER,

OR GRILL - SEE MECH

RETURN DIFFUSER, REGISTER,

OR GRILL - SEE MECH

RCP LEGEND

1-HR RATED SHAFTLINER CEILING

ASSEMBLY

2x2 CEILING SYSTEM

TO BE DEMOLISHED

2x4 CEILING SYSTEM

TO BE DEMOLISHED

GYPSUM BOARD CEILING

TO BE DEMOLISHED

RCP NOTES

GENERAL NOTE APPLICABLE TO ALL DRAWINGS - ITEMS AND CONDITIONS DETAILED NOTED OR

OTHERWISE IDENTIFIED ON ONE…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .