COMBINED DRAWINGS- 503-18-102 REPLACE HYDRAULIC ELEVATORS - BID DOCUMENTS.pdf
PDF 6 MB Posted
- Attached to
- K099--Replace Hydraulic Elevators Project # 503-18-102 Federal contract opportunity
- Solicitation number
- 36C24421B0001
About this file
This solicitation is for a construction project to replace two hydraulic elevators at the James E. Van Zandt VA Medical Center in Altoona, Pennsylvania. The project involves removing the existing hydraulic systems, controllers, wiring and jack assemblies for elevators P6 and P7 and replacing them with new equipment from the basement level to the third floor. The existing guide rails will be refurbished for reuse. Additional work includes replacing the door and louvers in the mechanical room with fire-rated components and infilling wall openings. The solicitation is issued by the Department of Veterans Affairs Veterans Health Administration for Project #503-18-102 with an estimated value over $2 million. The solicitation number is 36C24421B0001 and responses are due by the date specified on www.beta.SAM.gov.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24421B0001 0001_1.docx | DOCX document | |
| WD PA20200077.pdf | ||
| COMBINED SPECS 503-18-102 REPLACE HYDRAULIC ELEVATORS - BID DOCUMENT.pdf | ||
| 36C24421B0001_2.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2907 PLEASANT VALLEY BLVD.
ALTOONA, PA
LOCATION MAP
NOTE:
ALL WORK IS TO BE COMPLETED BETWEEN THE
HOURS OF 4:30pm - 5:00am.
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FULLY SPRINKLERED
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF PENNSYLVANIA, LICENSE
NUMBER 407296, EXPIRATION DATE 06/30/19
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTING ENGINEERING
1416 CLARKVIEW ROAD
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
ROBERT L. SEYMOUR & ASSOCIATES, INC.
VERTICAL TRANSPORTATION CONSULTANTS
182 THOMAS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BID DOCUMENTS
COVER SHEET REPLACE HYDRAULIC
ELEVATORS
CDP/ CAJ WPH/ DGW
6/27/2019
GI101
503-18-102
180101D
JAMES E. VAN ZANDT VETERANS
ADMINISTRATION MEDICAL CENTER
ALTOONA, PA.
REPLACE HYDRAULIC ELEVATORS
PROJECT # 503-18-102
INDEX OF DRAWINGS
DRAWING SHEET NAME
00 GENERAL INFORMATION
GI101 COVER SHEET
GI102 SYMBOLS, ABBREVIATIONS AND CODE
GI103 EXISTING ALTOONA CAMPUS PLAN
GI104 ICRA PLANS
04 ARCHITECTURE
AS101 BLDG 01 - PARTIAL BASEMENT FLOOR PLAN
AS102 BLDG 01 - BASEMENT FLOOR ENLARGED AREA OF WORK
AS103 BLDG 01 - PARTIAL 1ST FLOOR PLAN
AS104 BLDG 01 - 1ST FLOOR ENLARGED AREA OF WORK
AS105 BLDG 01 - PARTIAL 2ND FLOOR PLAN
AS106 BLDG 01 - 2ND FLOOR ENLARGED AREA OF WORK
AS107 BLDG 01 - PARTIAL 3RD FLOOR PLAN
AS108 BLDG 01 - 3RD FLOOR ENLARGED AREA OF WORK
AS601 DOOR SCHEDULE, DOOR AND FRAME TYPES
06 VERTICAL TRANSPORTATION
VT101 MACHINE ROOM AND PIT PLAN
VT102 ELEVATOR HOISTWAY PLAN
11 MECHANICAL
M001 MECHANICAL LEGEND, ABBREVIATIONS & GENERAL NOTES
MH101 BASEMENT FLOOR PLAN - MECHANICAL
MH102 1ST FLOOR PLAN - MECHANICAL - NEW WORK
MP101 BASEMENT FLOOR PLAN PLUMBING
14 ELECTRICAL
EP100 ELECTRICAL LEGEND, ABBREVIATIONS, GENERAL NOTES AND DETAILS
EP101 BLDG 01 - BASEMENT FLOOR PLAN - ELETRICAL
EP102 BLDG 01 - PART BASEMENT FLOOR PLAN - ELETRICAL - DEMO & NEW WORK
EP103 BLDG 01 - 1ST FLOOR PLAN - ELECTRICAL
EP104 BLDG 01 - PART 1ST FLOOR PLAN - ELECTRICAL DEMO & NEW WORK
EP105 BLDG 01 - PART 2ND FLOOR PLAN - ELECTRICAL DEMO & NEW WORK
EP106 BLDG 01 - PART 3RD FLOOR PLAN - ELECTRICAL DEMO & NEW WORK
EP107 PARTIAL ONE LINE AND PANEL SCHEDULE
01 27
ABBREVIATIONS
A301
A301
OT
GYM10'-0"
A.F.F.
DETAIL TAG
COLUMN LINE BUBBLE TAG
CEILING HEIGHT TAG
A-?
DWG NAME
SCALE:
SECTION TAG
ROOM TAG - NEW WORK
WINDOW TAG
WALL TYPE TAG
TITLE TAG
W05
INTERIOR ELEVATION
EXTERIOR ELEVATION
ELEVATION MARK
DETAIL CALL OUT
TAG
REVISION TAG
FIRST FLOOR
DOOR TAG
CONSTRUCTION KEY
NOTE TAG
X
D1-202A
A201
A201
125 SF
STOREFRONT
WINDOW TAG
S05
INTERIOR
WINDOW TAG
i05 S05
STOREFRONT
WINDOW TAG - WIDE
BUILDING DATA AND CODE REVIEW
PROJECT NAME: VA ALTOONA - REPLACE HYDRAULIC ELEVATORS
PROJECT LOCATION: 2907 PLEASANT VALLEY BOULEVARD
ALTOONA, PA 16602-4377
GENERAL DESCRIPTION:
APPLICABLE CODES:
SYMBOLS
ABA ACCESSIBILITY STANDARD FOR FEDERAL FACILITIES,
VA FIRE PROTECTION DESIGN MANUAL 1.5
NFPA 101-2015 LIFE SAFETY CODE
NFPA 220-2015 LIFE SAFETY CODE
AB ANCHOR BOLT
ABA ARCHITECTURAL BARRIERS ACT
AC AIR CONDITIONING
A/E ARCHITECT / ENGINEER
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
ALUM ALUMINUM
APPROX. APPROXIMATE
ARCH ARCHITECT (URAL)
BD BOARD
BFF BELOW FINISH FLOOR
BIT BITUMINOUS
BLDG BUILDING
BLK BLOCK
BM BENCH MARK
BOT BOTTOM
BPL BEARING PLATE
BS BOTH SIDES
BSMT BASEMENT
BUR BUILT UP ROOF
CB CATCH BASIN
CEM CEMENT
CI CAST IRON
CJT CONTROL JOINT
CLG CEILING
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS, CONTINUE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CT CERAMIC TILE
CU CUBIC
D DRAIN
DEM DEMOLISH, DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DL DEAD LOAD
DR DOOR
DS DOWNSPOUT
DTL DETAIL
DWG DRAWING
ELEC ELECTRIC (AL)
ELEV ELEVATION
EMER EMERGENCY
EST ESTIMATE
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION, EXPOSED
EXT EXTERIOR
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FFL FINISHED FLOOR LINE
FIN FINISH (ED)
FLG FLASHING
FLR FLOOR (ING)
FND FOUNDATION
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GD GRADE, GRADING
GHM GALVANIZED HOLLOW METAL
GMU GLAZED MASONRY UNIT
GWB GYPSUM WALL BOARD
GYP GYPSUM
HB HOSE BIB
HC HOLLOW CORE
HDW HARDWARE
HM HOLLOW METAL
HOR HORIZONTAL
HPL HIGH PRESSURE LAMINATE
HVAC HEATING VENTILATING AIR
CONDITIONING
HWH HOT WATE HEATER
ID INSIDE DIAMETER
IGU INSULATED GLASS UNIT
INCL INCLUDE (D) (ING)
INSUL INSULATION
INT INTERIOR
INV INVERT
JT JOINT
KO KNOCK OUT
LAV LAVATORY
LBL LABEL
LH LEFT HAND
LPL LOW PRESSURE LAMINATE
LT LIGHT
MAS MASONRY
MAX MAXIMUM
MBL MARBLE
MDO MEDIUM DENSITY OVERLAY
MECH MECHANICAL
MED MEDIUM
MFR MANUFACTURE (ER)
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTL METAL
N NORTH
NIC NOT IN CONTRACT
NTS NOT TO SCALE
NOM NOMINAL
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD
OPG OPENING
PER PERIMETER
PFG POLISHED FLOAT GLASS
PL PROPERTY LINE
P-LAM PLASTIC LAMINATE
PLAS PLASTER
PLK CONCRETE PLANK - PAINTED
PLT PLATE
PNL PANEL
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT
PVC POLYVINYL CHLORIDE
PWD PLYWOOD
QT QUARRY TILE
R RADIUS
RI RISER
RA RETURN AIR
RCP REFLECTED CEILING PLAN
REF REFERENCE
REV REVISION, REVISED
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
S SOUTH
SCH SCHEDULE
SEC SECTION
SF SEAMLESS FLOOR
SIM SIMILAR
SPEC SPECIFICATION (S)
SQ SQUARE
ST STRAIGHT
STL STEEL
STO STORAGE
STR STRUCTURAL
SW SWITCH (ES)
SYS SYSTEM
TBD TO BE DETERMINED
TFG TEMPERED FLOAT GLASS
T&G TONGUE & GROOVE
THK THICK (NESS)
TYP TYPICAL
VCD VINYL COVERED DRYWALL
VCT VINYL COMPOSITION TILE
VERT VERTICAL
W WEST, WIDTH, WIDE
W/ WITH
WB WOOD BASE
WC WATER CLOSET
WD WOOD
WG WIRE GLASS
WP WATERPROOF (ING)
WWF WELDED WIRE FABRIC
This project consist of replacing two (2) existing hydraulic elevators ( P6 & P7) pump units, controllers/wiring and jack assemblies going from the Basement Level to the Third Floor with two (2) new hydraulic elevators, pump units, controllers/wiring and jack assemblies, The existing guide rails will be inspected and refurbished for use with the new elevators. The existing door to the Mechanical room BE01I will be replaced with a new 90 min rated door and hardware, and two (2) existing louvers in the same room will be removed and infilled to match existing wall type and fire rating. At the Third floor lobby/ elevator shaft a louver will be removed and infilled to match existing wall type and fire rating.
Basement level: Elevator Pit BE01J First Floor lobby: Corridor 1F1 Second Floor lobby: Corridor 2B2 Third Floor lobby: Corridor 3B1
NFPA 220 Institutional TYPE II (222) Occuoancy Existing Health Care
Number of Exits per floor/ space Three (3) Number of hoizontal exits utilized None
EXISTING FIRE RATINGS:
CORRIDORS NONE - FULLY SPRINKLERED
VERTICAL OPENING ENCLOSURES 2 HOUR
VERTICAL OPENING PROTECTIVE DEVICES 1.5 HOUR
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FULLY SPRINKLERED
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF PENNSYLVANIA, LICENSE
NUMBER 407296, EXPIRATION DATE 06/30/19
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTING ENGINEERING
1416 CLARKVIEW ROAD
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
ROBERT L. SEYMOUR & ASSOCIATES, INC.
VERTICAL TRANSPORTATION CONSULTANTS
182 THOMAS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BID DOCUMENTS
SYMBOLS, ABBREVIATIONS
AND CODE
REPLACE HYDRAULIC
ELEVATORS
CDP/ CAJ WPH/ DGW
6/27/2019
GI102
503-18-102
180101D
02 27
BLDG. 01
PLEASANT VALLEY BOULEVARD
S.
7T H
S
TR
EE
T
S.
7T H
S
TR
EE
T
S.
7T H
S
TR
EE
T
CAYUGA
CIRCLE
MAIN ENTRANCE ROAD
1 CONTRACTOR TO VERIFY ACCESS ROUTES AND POTENTIAL LAY DOWN AREA
WITH THE COR PRIOR TO CONSTRUCTION.
NOTE: CONTRACTOR RESPONSIBLE FOR SECURING MATERIALS
I.E. CONTRACTOR AREAS TO BE LOCKED WHEN
UNMANNED AND LATCHED WHEN MANNED.
CONTRACTOR PARKING
IN BOTTOM ROW
* ALL CONTRACTOR ACCESS ROUTES MUST BE PRE AUTHORIZED WITH THE VA COR
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FULLY SPRINKLERED
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF PENNSYLVANIA, LICENSE
NUMBER 407296, EXPIRATION DATE 06/30/19
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTING ENGINEERING
1416 CLARKVIEW ROAD
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
ROBERT L. SEYMOUR & ASSOCIATES, INC.
VERTICAL TRANSPORTATION CONSULTANTS
182 THOMAS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BID DOCUMENTS
EXISTING ALTOONA
CAMPUS PLAN
REPLACE HYDRAULIC
ELEVATORS
CDP/ CAJ WPH/ DGW
6/27/2019
GI103
503-18-102
180101D
SCALE: 1" = 50'
25' 50'0 100'
PROJECT NORTH
TRUE NORTH
SCALE: 1" = 50'-0"
EXIST ALTOONA CAMPUS PLAN
03 27
MECHANICAL ROOM
BE01I
STORAGE,
EQUIPMENT / CAGE
BE01H
ELEVATOR PIT
BE01J
STORAGE,
EQUIPMENT / CAGE
BE01K
BE01I
CONTRACTOR CAN USE
THIS SPACE FOR STORAGE
DURING CONSTRUCTION.
CHECK-IN
1F42
PHARMACY
1F10
CORRIDOR
1F1
WAITING
1F09
CORRIDOR
1G2
RX PICK-UP
1F08
ELEV.
P7
ELEV.
P6
VENDING
1G11
CHECK-OUT/BLUE
TEAM CLERK
1F43
5' -6
" M
IN
ELEV.
P7
ELEV.
P6
ALIGN WITH
DOOR JAMB
OR SMALLER
WAITING
3F01
OFFICE
3F02 ELEV.
P7
ELEV.
P6
RESTROOM, ADA
3F04A
EXAM 3
3F04
NURSE
WORKSTATION
3F07
OR
3F03
CORRIDOR
3B1 WAREHOUSE SPS
3E05
ICRA LEGEND
DOOR ACCESS TO WORK AREA
ICRA BARRIER
ICRA GENERAL REQUIREMENTS
1. CONTRACTOR TO COORDINATE ALL ICRA BARRIER LAYOUT AND
WORK WITH THE COR AND VA SAFETY PRIOR TO CONSTRUCTION.
2. ADHESIVE WALK OFF MATTS WILL BE USED AT THE EXITS OF
EVERY WORK AREA.
3. FAN UNITS WILL BE PLACED AS NEEDED TO CREATE NEGATIVE
PRESSURE FOR THE AREA WORK IS BEING DONE IN. EXHAUST TO
EXTERIOR OF BUILDING, WHERE POSSIBLE.
ICRA GENERAL NOTES
1. CONTRACTOR TO PROVIDE ICRA BARRIER LAYOUT AND DETAILS TO
THE COR AND VA SAFETY PRIOR TO CONSTRUCTION.
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FULLY SPRINKLERED
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF PENNSYLVANIA, LICENSE
NUMBER 407296, EXPIRATION DATE 06/30/19
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTING ENGINEERING
1416 CLARKVIEW ROAD
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
ROBERT L. SEYMOUR & ASSOCIATES, INC.
VERTICAL TRANSPORTATION CONSULTANTS
182 THOMAS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BID DOCUMENTS
ICRA PLANS REPLACE HYDRAULIC
ELEVATORS
Checker Author
6/27/2019
GI104
503-18-102
180101DSCALE: 1/4" = 1'-0"GI104
1 ENLARGED BASEMENT FLOOR ICRA PLAN
SCALE: 1/4" = 1'-0"GI104
2 ENLARGED FIRST FLOOR ICRA PLAN
SCALE: 1/4" = 1'-0"GI104
3 ENLARGED SECOND FLOOR ICRA PLAN
SCALE: 1/4" = 1'-0"GI104
4 ENLARGED THIRD FLOOR ICRA PLAN
PROJECT NORTH
TRUE NORTH
SCALE: 1/4" = 1'-0"
2'-0" 4'-0"0 8'-0"
04 27
BD01
ELECTRICAL ROOM
BD01A
PUMP ROOM
BD01B
KEY PLAN
AREA OF WORK
BA06BA11
BA13BA17
BA15
BA15A
BA16
BA18
BA20
BA21 BA22
BA10
BA05
BA05A
BA03
BC01A
BA06A BA04
BA02
BB01
BB03
BB05
BB09
BB04
BB02
BB06
BB08
BB08A
BB11
BB12
BB10
BC01
BA10A
BC11
BC12
BC10A
BC08
BC06
BC04
BC05
BC02
BB15C
BB15G BB15H BB15I BB15J BB15K BB15L BB15M
BB15
BB13
BB13A
BB16
BE01J
BE01I
BB15D
BB15F
BB15E
BB15B
STAIR
FB
BE01F
BE01D
STAIR
AB
STAIR
CB
STAIR
DB
BA12
BA09
S4
F5
P3
P2
BA05B
BA01
BB07
STAIR
BB
BB14
BC07
BC09
BA02A
BA19
STAIR
EB
BC03
BE01B
BE01A
BE01N
BE01M
BE01H BE01K
CORRIDOR
BA1
CORRIDOR
BA2
CORRIDOR
BA3
CORRIDOR
BB1
CORRIDOR
BC1
CORRIDOR
BC2
BB15A
BC01A1
BB16A
BE01L
BE01C
BE01E
BE01G
BE01
BE01O
BC10
BC08A
BA11A
AS102
AS102
1 MAY BE USED BY CONTRACTOR FOR MATERIAL STORAGE DURING CONSTRUCTION
2 CONTRACTOR ACCESS ROUTE; NOTE LOW HEAD HEIGHTS AS SHOWN ON PHOTO A.
CONTRACTOR TO COORDINATE MATERIAL MOVEMENT WITH COR AT LEAST 2 WEEKS
IN ADVANCE .
NOTE:
3 MATERIAL HOIST-WAY MAY BE USED BY CONTRACTOR.
NOT FOR TRANSPORT OF PERSONNEL.
GI104
4' -8
" F R
O M
F
LO
O R
T O
U N
D
ER
SI
D
E O
F D
U C
T
3' -9
" F R
O M
F
LO
O R
T O
U N
D
ER
SI
D
E O
F
PI
PE
NOTE:
LOW HEAD HEIGHTS ALONG ACCESS ROUTE
PHOTO A
EXISTING PIPE
EXISTING DUCT
LINE REPRESENTS LEVEL
OF EXISTING FINISH FLOOR
NOTE:
ALL WORK IS TO BE COMPLETED BETWEEN THE
HOURS OF 4:30pm - 5:00am.
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FULLY SPRINKLERED
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF PENNSYLVANIA, LICENSE
NUMBER 407296, EXPIRATION DATE 06/30/19
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTING ENGINEERING
1416 CLARKVIEW ROAD
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
ROBERT L. SEYMOUR & ASSOCIATES, INC.
VERTICAL TRANSPORTATION CONSULTANTS
182 THOMAS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BID DOCUMENTS
BLDG 01 - PARTIAL
BASEMENT FLOOR PLAN
REPLACE HYDRAULIC
ELEVATORS
CDP/ CAJ WPH/ DGW
6/27/2019
AS101
503-18-102
180101DSCALE: 1/16" = 1'-0"AS101
1 NEW BASEMENT FLOOR - PART B - ZONE D
PROJECT NORTH
TRUE NORTH
SCALE: 1/16" = 1'-0"
8'-0" 16'-0"0 32'-0"
SCALE: 1/16" = 1'-0"AS101
3 NEW BASEMENT FLOOR - PART A
05 27
SCALE: 3" = 1'-0"AS101
4 HEAD HEIGHT CLEARANCE
BE01I
MECHANICAL ROOM
BE01F
STORAGE,
EQUIPMENT / CAGE
BE01H
ELEVATOR PIT
BE01J
STORAGE,
EQUIPMENT / CAGE
BE01K
6'-0" 3'-2"
EXISTING BEAM
AT CEILING
AS102
AS102 3
2' -8
1'
-7
KEY PLAN
AREA OF WORK
MECHANICAL ROOM
BE01I
MECHANICAL ROOM
BE01F
STORAGE,
EQUIPMENT / CAGE
BE01H
ELEVATOR PIT
BE01J
STORAGE,
EQUIPMENT / CAGE
BE01K
NEW WORK NOTE:
INFILL EXISTING WALL
OPENINGS TO MATCH
EXISTING WALL MATERIAL
AND FINISH.
EXISTING BEAM
AT CEILING, TO
BE PAINTED P-1
BE01I
NEW 90 MIN FIRE RATED DOOR
AND FRAME TO MATCH EXISTING
DOOR IN SIZE AND MATERIAL,
DOOR SWING IS DIFFERENT
FROM EXISTING. SEE DOOR
SCHEDULE ON SHEET AS601
BE01J
NOTE:
SEE DOOR SCHEDULE ON SHEET AS601
CONTRACTOR CAN USE
THIS SPACE FOR STORAGE
DURING CONSTRUCTION.
EXIST BASEMENT
FLOOR
-10'-0"
3'-2"6'-0"
1' -7
4'
-0
DEMO EXISTING
SUPPLY DUCT AT
WALL ONLY
EXIST BASEMENT
FLOOR
-10'-0"
1'-7" 2'-8"
5' -4
" V
ER
IF
Y
2' -6
DEMO EXISTING LOUVER
AT WALL ONLY
NOTES:
1. THE CONTRACTOR IS TO DOCUMENT THE LOCATION, EXACT
CONSTRUCTION AND APPEARANCE OF ALL WALLS, MILLWORK,
FINISHES, ELECTRICAL, I.T., PLUMBING AND FIXTURES OF
AFFECTED AREAS PRIOR TO DEMOLITION.
2. IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO
REPLACE ALL WALLS, MILLWORK FINISHES, ELECTRICAL, I.T.,
PLUMBING AND FIXTURES AS THEY WERE PRIOR TO DEMOLITION.
3. CONTRACTOR TO PROTECT ALL EXISTING FINISHES DURING
DEMOLITION AND CONSTRUCTION. CONTRACTOR TO REPAIR ANY
DAMAGE TO EXISTING FINISHES. ALL NEW AND REPLACED
FINISHES ARE TO MATCH EXISTING.
4. CONTRACTOR MAY TEMPORARILY REMOVE ANY HANDRAILS
OR OTHER FINISHES WITH VA APPROVAL. ALL REMOVED
HANDRAILS AND FINISHES ARE TO BE PUT BACK IN THEIR ORIGINAL
POSITION, CLEANED & RESTORED TO THEIR PRE-CONSTRUCTION
CONDITION.
5. CONTRACTOR TO NOTIFY AND RECEIVE PERMISSION FROM
COR BEFORE DEMOLISHING ANY PART OF THE EXISTING BUILDING
THAT IS NOT COVERED IN THE DEMOLITION DRAWINGS.
6. CONTRACTOR TO FIX ANY DAMAGE TO EXISTING FINISHES
CAUSED BY CREWS DURING DEMOLITION OR CONSTRUCTION
7. CONTRACTOR TO PAINT ALL NEW WORK AND VARIOUS
PATCHES TO MATCH THE EXISTING CONDITIONS, OR AS DIRECTED
BY THE VA. IF AN EXACT PAINT MATCH CAN NOT BE MADE, THE
CONTRACTOR MUST PAINT THE ENTIRE WALL CORNER TO
CORNER, FLOOR TO CEILING WITH NEW PAINT THAT IS A CLOSE
MATCH OR A COMPLIMENTARY COLOR. ALL SURFACES NOT BEING
PAINTED ARE TO BE PROTECTED. SEE FINISH SCHEDULE FOR
MORE PAINT INFORMATION.
8. CONTRACTOR TO COORDINATE NOISE GENERATING
ACTIVITIES WITH COR PRIOR TO CONSTRUCTION START; AS
EXCESSIVELY LOUD OPERATIONS WILL NEED TO BE
ACCOMPLISHED AFTER NORMAL WORKING HOURS.
9. TRASH REMOVAL AND MATERIAL DELIVERIES SHALL BE LIMITED
SPECIFIC HOURS AS DIRECTED AND COORDINATED WITH THE
COR.
10. ALL TEMPORARY CONSTRUCTION BARRIERS, DOORS AND
FRAMES SHALL HAVE A 1 HOUR FIRE RATING.
NOTE:
ALL WORK IS TO BE COMPLETED BETWEEN THE
HOURS OF 4:30pm - 5:00am.
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FULLY SPRINKLERED
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF PENNSYLVANIA, LICENSE
NUMBER 407296, EXPIRATION DATE 06/30/19
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTING ENGINEERING
1416 CLARKVIEW ROAD
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
ROBERT L. SEYMOUR & ASSOCIATES, INC.
VERTICAL TRANSPORTATION CONSULTANTS
182 THOMAS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BID DOCUMENTS
BLDG 01 - BASEMENT
FLOOR ENLARGED AREA OF
WORK
REPLACE HYDRAULIC
ELEVATORS
CDP/ CAJ WPH/ DGW
6/27/2019
AS102
503-18-102
180101D
PROJECT NORTH
TRUE NORTHSCALE: 1/4" = 1'-0"
2'-0" 4'-0"0 8'-0"
SCALE: 1/4" = 1'-0"AS102
BASEMENT FLOOR -ENLARGED AREA OF WORK -
DEMOLITION
06 27
SCALE: 1/4" = 1'-0"AS102
BASEMENT FLOOR -ENLARGED AREA OF WORK -
NEW
SCALE: 1/2" = 1'-0"AS102
PARTIAL DEMO. NORTH ELEV. - MECH ROOM
BE01I
SCALE: 1/2" = 1'-0"AS102
3 PARTIAL DEMO. EAST ELEV. - MECH ROOM BE01I
1 CUT EXISTING FLOOR SLAB AND POUR PIT FOR SUMP PUMP TO BE INSTALLED.
GENERAL NOTES
2 WALLS TO BE PAINTED; P-1: SW0050 "CLASSIC LIGHT BUFF"
3 ELEVATOR CAB WALL PANELS FINISH TO BE; PLAM-1: WILSONART OXIDE 1787-60, MATTE FINISH ELEVATOR CAB FLOOR FINISH TO BE : LVT-1: ARMSTRONG NATURAL CREATIONS, MYSTIX STREAM NA893 ELEVATOR CAB CEILING TO BE: ALUMINUM T TYPE DROP CEILING FRAME W/ ACRYLIC WHITE DIFFUSER
PANELS TO CREATE 6 EQUAL PANEL CEILING
4 DOOR AND FRAME TO BE PAINTED P-2: SW7025 BACKDROP
ROOM FINISH SCHEDULE
NAME NUMBER
FLOOR
FINISH BASE
WALL
CEILING FINISH
CEILING
HEIGHT Comments
NORTH
WALL
EAST
WALL
SOUTH
WALL
WEST
WALL
CORRIDOR 1F1 (none) N/A N/A N/A N/A EXISTING ACT 9'-0" REPAIR AND PAINT AS NEEDED TO MATCH EXISTING CORRIDOR 2B2 (none) N/A N/A N/A N/A EXISTING ACT 8'-0" REPAIR AND PAINT AS NEEDED TO MATCH EXISTING CORRIDOR 3B1 (none) N/A N/A N/A N/A EXISTING ACT 8'-0" REPAIR AND PAINT AS NEEDED TO MATCH EXISTING MECHANICAL ROOM BE01I (none) P-1 P-1 P-1 P-1 OPEN TO ABOVE PAINT EXISTING BEAM AT CEILING AT SOUTH WALL - SEE PLAN
* ALL FINISHES TO BE SUBMITTED PRIOR TO CONSTRUCTION AND APPROVED BY VA COR
1E35C 1E34A
1E34
1E35A
1E33 1E31 1E30 1E28 1E26 1E25
1E32
1E24A
1E24
1E07
1E27
1E10 1E11
1E11B
1E11A
1E29STAIR
A1
1E37
1E37A
1E36
1E36A 1E17
1E20
1E35
1E17A
1E21 1E23
1E22
1E18
1E14 1E12
1E15
1E13 1E09 1E08 1E06 1E05
1E16
1E03B 1E01
1E03A
1E03C
1E03D 1E03F 1E03G
1F02
1F03A1
1F03
1F03A
1F04
1F05A
1F05
1F07A
1F06
1G19
1G18 1G17 1G16 1G14C
1G14
1G14A 1G14B1G19A
1G12A
1G15 1G12B 1G12C 1G12E 1G12G
1G12I 1G07 1G06
STAIR
C1
1F08B
1F08A
1F08
1G09
1G08
1G05
1G04
1G03
1G02B
1G02
1A19 1A19A
1A171A17A
STAIR
B1
1G12
1A03A 1A03B 1A03C 1A03D
1A03E
1A03
1A02
1A04 1A10B
1A10A
WAITING
1A01
1A20
1A18
1A16
1A38 1A39 1A40
1A41
1A15
1A14
1A131A221A23 1A37B
1A36
1A31
1A35
1A34
1A33
1A32 1A25
1A24 1A21 1A11
1A26
1A271A281A291A30
STAIR
F1
1A12A
1A12
1A09D 1A09C 1A09B 1A09A 1A07
1A05
1G10
1F43 1F44
1F471F48
1F50
1F52
1F51
1F53A 1F49 1F54
1F46
1F55
1F56
1F10
1F10D
1F10E 1F58 1F57
1F45
1F53B
1F62 1F631F651F67
1F69A 1F59
1F69
1F68 1F66 1F64 1F61
1F70
1F72 1F73
1F71
1F07
1E37A2 1G12D
1G02A
1G02F1
1G02F
1G02D
1G02E
1G02G
1E03
1E19
1E02 1F01
1G20
1E04
1G13
1G12F 1G12H
1G01
1G11
1A08 1A10
1A37A
1A37
1F10C
1F42
1F60
1E03E
1E35B
1E05A
1F09
1G19B 1G19C
1A00
1A06
1E38
1F74
1G02C
STAIR
E1
CORRIDOR
1A1
CORRIDOR
1A2
CORRIDOR
1A3
CORRIDOR
1A4
CORRIDOR
1E1
CORRIDOR
1E5
CORRIDOR
1E4
CORRIDOR
1E2
CORRIDOR
1F1
CORRIDOR
1G1
CORRIDOR
1G2
CORRIDOR
1F2
P7
P6
F5
S4
P3
P2
CORRIDOR
1E3
1E39
1F10A
1F10B
1F48A
1F53
1E03A1
1E37A1
AS104
1 CONTRACTOR ACCESS ROUTE; ALL MATERIAL MOVEMENT TO BE CONDUCTED
AFTER HOURS. CONTRACTOR TO COORDINATE MATERIAL MOVEMENT WITH COR
AT LEAST 2 WEEKS IN ADVANCE .
NOTE:
ALTERNATE ROUTE TO SECOND FLOOR
- MAY BE IN SEPARATE CONSTRUCTION AREA.
- CANNOT GUARANTEE AVAILABILITY.
ALTERNATE
ACCESS ROUTE
ALTERNATE
ACCESS ROUTE
POTENTIAL SEPARATE CONSTRUCTION ZONE
ALTERNATE ROUTE
TO 2ND FLOOR ONLY
ALTERNATE ROUTE
TO THIRD FLOOR
S4 SERVICE ELEVATOR - 4,000 LBS CAPACITY
PRIMARY ROUTE FROM GROUND FLOOR
USED BY CONTRACTOR FOR MATERIAL
MOVEMENT (TOOLS, EQUIPMENT/ MATERIALS)
GI104
PRIMARYACCESS
ROUTE
* ALL CONTRACTOR ACCESS ROUTES MUST BE PRE AUTHORIZED WITH THE VA COR
KEY PLAN
AREA OF WORK
NOTE:
ALL WORK IS TO BE COMPLETED BETWEEN THE
HOURS OF 4:30pm - 5:00am.
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FULLY SPRINKLERED
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF PENNSYLVANIA, LICENSE
NUMBER 407296, EXPIRATION DATE 06/30/19
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTING ENGINEERING
1416 CLARKVIEW ROAD
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
ROBERT L. SEYMOUR & ASSOCIATES, INC.
VERTICAL TRANSPORTATION CONSULTANTS
182 THOMAS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BID DOCUMENTS
BLDG 01 - PARTIAL 1ST
FLOOR PLAN
REPLACE HYDRAULIC
ELEVATORS
CDP/ CAJ WPH/ DGW
6/27/2019
AS103
503-18-102
180101D
SCALE: 1/16" = 1'-0"
8'-0" 16'-0"0 32'-0"
PROJECT NORTH
TRUE NORTH
SCALE: 1/16" = 1'-0"AS103
2 NEW 1ST FLOOR - PART A
07 27
KEY PLAN
AREA OF WORK
CHECK-IN
1F42
PHARMACY
1F10
OFFICE
1F44
CORRIDOR
1F1
WAITING
1F09
CORRIDOR
1G2
RX PICK-UP
1F08
ELEV.
P7
ELEV.
P6
VENDING
1G11
RX DROP-OFF
1F08B
CHECK-OUT/BLUE
TEAM CLERK
1F43
NOTE:
ALL WORK IS TO BE COMPLETED BETWEEN THE
HOURS OF 4:30pm - 5:00am.
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FULLY SPRINKLERED
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF PENNSYLVANIA, LICENSE
NUMBER 407296, EXPIRATION DATE 06/30/19
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTING ENGINEERING
1416 CLARKVIEW ROAD
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
ROBERT L. SEYMOUR & ASSOCIATES, INC.
VERTICAL TRANSPORTATION CONSULTANTS
182 THOMAS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BID DOCUMENTS
BLDG 01 - 1ST FLOOR
ENLARGED AREA OF WORK
REPLACE HYDRAULIC
ELEVATORS
CDP/ CAJ WPH/ DGW
6/27/2019
AS104
503-18-102
180101D
SCALE: 1/4" = 1'-0"AS104
1 1ST FLOOR - ENLARGED AREA OF WORK
SCALE: 1/4" = 1'-0"
2'-0" 4'-0"0 8'-0"
PROJECT NORTH
TRUE NORTH
08 27
F5
P6
EXISTING
ROOF BELOW
P3
P2
S4
P7
AS106
ALTERNATE ACCESS ROUTE FROM THE GROUND
FLOOR
- MAY BE IN SEPARATE CONSTRUCTION AREA.
- CANNOT GUARANTEE AVAILABILITY.
ALTERNATE ACCESS ROUTE
FROM THE GROUND FLOOR
S4 SERVICE ELEVATOR - 4,000 LBS CAPACITY
PRIMARY ROUTE FROM GROUND FLOOR
USED BY CONTRACTOR FOR MATERIAL
MOVEMENT (TOOLS, EQUIPMENT/ MATERIALS)
GI104
KEY PLAN
AREA OF WORK
NOTE:
ALL WORK IS TO BE COMPLETED BETWEEN THE
HOURS OF 4:30pm - 5:00am.
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FULLY SPRINKLERED
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF PENNSYLVANIA, LICENSE
NUMBER 407296, EXPIRATION DATE 06/30/19
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTING ENGINEERING
1416 CLARKVIEW ROAD
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
ROBERT L. SEYMOUR & ASSOCIATES, INC.
VERTICAL TRANSPORTATION CONSULTANTS
182 THOMAS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BID DOCUMENTS
BLDG 01 - PARTIAL 2ND
FLOOR PLAN
REPLACE HYDRAULIC
ELEVATORS
CDP/ CAJ WPH/ DGW
6/27/2019
AS105
503-18-102
180101D
SCALE: 1/16" = 1'-0"
8'-0" 16'-0"0 32'-0"
SCALE: 1/16" = 1'-0"AS105
2 NEW 2ND FLOOR - PART A
PROJECT NORTH
TRUE NORTH
09 27
ELEV.
P7
ELEV.
P6
CORRIDOR
2B2
KEY PLAN
AREA OF WORK
NOTE:
ALL WORK IS TO BE COMPLETED BETWEEN THE
HOURS OF 4:30pm - 5:00am.
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FULLY SPRINKLERED
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF PENNSYLVANIA, LICENSE
NUMBER 407296, EXPIRATION DATE 06/30/19
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTING ENGINEERING
1416 CLARKVIEW ROAD
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
ROBERT L. SEYMOUR & ASSOCIATES, INC.
VERTICAL TRANSPORTATION CONSULTANTS
182 THOMAS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BID DOCUMENTS
BLDG 01 - 2ND FLOOR
ENLARGED AREA OF WORK
REPLACE HYDRAULIC
ELEVATORS
CDP/ CAJ WPH/ DGW
6/27/2019
AS106
503-18-102
180101D
SCALE: 1/4" = 1'-0"
2'-0" 4'-0"0 8'-0"
PROJECT NORTH
TRUE NORTH
SCALE: 1/4" = 1'-0"AS106
1 2ND FLOOR ENLARGED AREA OF WORK
10 27
3B01
3B02
3B03
3B06 3B05
3B08 3B07
3B09 3B10
3A01
3B01A
3B01B
3B01B1
3B01C 3E03
3E01 3E01A
3E02
3E02A
3F15 3F16 3F18 3F20
3F21
3F19
3F17
3F14
3F24
3F13
3F12
3F11
3F10
3FO9
3F05
3E05
3E05D
3E04C 3E04B
3E04
3E04A
STAIR
B3
3E05C
3E05B
3E05A
3F08B
3F08A
3F08
3F01
3F02
3B09A 3B11
3B15
3B16
3B18
3B20
3B21
3B22E
3B22E1
3B19
3B17
3B14
3B13
3B12
3B22F
3B22
3B22A
3B22B 3B22C 3B22D 3B22G
3B22H
3F22
3F23
3F12A
3F25
3F11A 3F11A1
3F10A1
3F10A
3F26
3F06
3F06A 3F05A
3F07
STAIR
E3
SPECIALTY CLINIC
KIOSK CHECK-IN
3C01
3F04
3F04A
OR
3F03
CORRIDOR
3C1
CORRIDOR
3A1
CORRIDOR
3B1
CORRIDOR
3B2
CORRIDOR
3F1
3E01B
P3
P2
S4
AS108
ELEV.
P7
ELEV.
P6
S4 SERVICE ELEVATOR - 4,000 LBS CAPACITY
PRIMARY ROUTE FROM GROUND FLOOR
USED BY CONTRACTOR FOR MATERIAL
MOVEMENT (TOOLS, EQUIPMENT/ MATERIALS)
ALTERNATE ROUTE
FROM GROUND FLOOR
GI104
KEY PLAN
AREA OF WORK
NOTE:
ALL WORK IS TO BE COMPLETED BETWEEN THE
HOURS OF 4:30pm - 5:00am.
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FULLY SPRINKLERED
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF PENNSYLVANIA, LICENSE
NUMBER 407296, EXPIRATION DATE 06/30/19
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTING ENGINEERING
1416 CLARKVIEW ROAD
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
ROBERT L. SEYMOUR & ASSOCIATES, INC.
VERTICAL TRANSPORTATION CONSULTANTS
182 THOMAS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BID DOCUMENTS
BLDG 01 - PARTIAL 3RD
FLOOR PLAN
REPLACE HYDRAULIC
ELEVATORS
CDP/ CAJ WPH/ DGW
6/27/2019
AS107
503-18-102
180101D
SCALE: 1/8" = 1'-0"AS107
2 NEW 3RD FLOOR - PART B - ZONES B, E & F
SCALE: 1/8" = 1'-0"
4'-0" 8'-0"0 16'-0"
PROJECT NORTH
TRUE NORTH
11 27
WAITING
3F01
OFFICE
3F02 ELEV.
P7
ELEV.
P6
RESTROOM, ADA
3F04A
EXAM 3
3F04
NURSE
WORKSTATION
3F07
OR
3F03
CORRIDOR
3B1 WAREHOUSE SPS
3E05
LOUVER TO BE REMOVED;
SEE MECHANICAL DRAWINGS FOR LOCATION.
INFILL EXISTING HOLE TO MATCH EXISTING
WALL TYPE AND FIRE RATING.
KEY PLAN
AREA OF WORK
NOTE:
ALL WORK IS TO BE COMPLETED BETWEEN THE
HOURS OF 4:30pm - 5:00am.
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FULLY SPRINKLERED
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF PENNSYLVANIA, LICENSE
NUMBER 407296, EXPIRATION DATE 06/30/19
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTING ENGINEERING
1416 CLARKVIEW ROAD
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
ROBERT L. SEYMOUR & ASSOCIATES, INC.
VERTICAL TRANSPORTATION CONSULTANTS
182 THOMAS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BID DOCUMENTS
BLDG 01 - 3RD FLOOR
ENLARGED AREA OF WORK
REPLACE HYDRAULIC
ELEVATORS
CDP/ CAJ WPH/ DGW
6/27/2019
AS108
503-18-102
180101D
SCALE: 1/4" = 1'-0"
2'-0" 4'-0"0 8'-0"
PROJECT NORTH
TRUE NORTH
SCALE: 1/4" = 1'-0"AS108
1 3RD FLOOR -ENLARGED AREA OF WORK
12 27
NO. WIDTH HEIGHT THICK DOOR TYPE DOOR MTRL DOOR FINISH FIRE RATING
DOOR
FRAME TYPE FRAME MTRL FRAME FINISH
FRAME
BE01I
BE0IJ
3'-6" 7'-0" 2" A HM PT
3'-6" 7'-0" 2" EXIST EXIST EXIST
1 HM PT
EXIST EXIST EXIST
- DOOR ACCESS HARDWARE TO BE SALTO
- SEE SPECIFICATIONS 08 71 00 FOR MORE
INFORMATION
HEAD
DETAILS
JAMB COMMENTS
EXISTING DOOR TO RECEIVE NEW HARDWARE:
- DOOR ACCESS HARDWARE TO BE SALTO
- SEE SPECIFICATIONS 08 71 00 FOR MORE
INFORMATION
2 HR
EXIST 2 HR
DOOR SCHEDULE
1/AS601 1/AS601
N/A N/A
DOOR SCHEDULE ABBREVIATIONS
EXIST - EXISTING
HM - HOLLOW METAL
N/A - NOT APPLICABLE
PT - PAINT
STL - STEEL
DOOR TYPE A
DOOR TYPE
FRAME TYPE
EXISTING CMU WALL
STANDARD RABBET
HOLLOW METAL FRAME
- GROUT FULL
SEE DOOR SCHEDULE
EXISTING CMU WALL
STANDARD RABBET
HOLLOW METAL FRAME
- GROUT FULL
SEE DOOR SCHEDULE
JAMB ANCHOR
HEAD JAMB
NOTE:
ALL WORK IS TO BE COMPLETED BETWEEN THE
HOURS OF 4:30pm - 5:00am.
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FULLY SPRINKLERED
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF PENNSYLVANIA, LICENSE
NUMBER 407296, EXPIRATION DATE 06/30/19
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTING ENGINEERING
1416 CLARKVIEW ROAD
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
ROBERT L. SEYMOUR & ASSOCIATES, INC.
VERTICAL TRANSPORTATION CONSULTANTS
182 THOMAS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BID DOCUMENTS
DOOR SCHEDULE, DOOR
AND FRAME TYPES
REPLACE HYDRAULIC
ELEVATORS
CDP/ CAJ WPH/ DGW
6/27/2019
AS601
503-18-102
180101D
SCALE: 1 1/2" = 1'-0"AS601
1 HEAD AND JAMB DETAILS
13 27
MECHANICAL GENERAL NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
THE MECHANICAL CONTRACT DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO INDICATE SCOPE AND THE GENERAL ARRANGEMENT OF THE SYSTEMS. WHERE APPLICABLE THE FOLLOWING NOTES SHALL APPLY TO ALL
MECHANICAL (HVAC, PLUMBING, PIPING AND FIRE PROTECTION) SYSTEMS.
THOUGH SOME DUCTWORK AND PIPING OFFSETS AND TRANSITIONS ARE INDICATED, IT IS NOT THE INTENT OF THE DRAWINGS TO SHOW ALL OFFSETS AND TRANSITIONS REQUIRED. THE CONTRACTOR SHALL FULLY COORDINATE THE MECHANICAL WORK WITHIN ITSELF AND WITH THE WORK OF ALL OTHER TRADES TO PROVIDE COMPLETE
AND OPERABLE SYSTEMS WITHOUT INTERFERENCES.
PROVIDE APPROVED FIRE STOPPING MATERIAL AROUND ALL DUCTWORK AND PIPING PENETRATIONS (NEW AND EXISTING) THROUGH FIRE RATED FLOORS AND WALLS. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF FIRE RATED FLOORS AND WALLS. PROVIDE FIRE DAMPERS AT ALL DUCT PENETRATIONS THROUGH FLOORS AND FIRE RATED WALLS AND FIRE/SMOKE DAMPERS AT ALL PENETRATIONS THROUGH SHAFT ENCLOSURES.
INSTALL DUCTWORK AND PIPING MAINS TIGHT TO UNDERSIDE OF STRUCTURE UNLESS OTHERWISE INDICATED.
AIR CONDITIONING (A/C) CONDENSATE PIPING SHALL BE EXTENDED FROM ALL A/C CONDENSATE SOURCE EQUIPMENT (SPLIT SYSTEM A/C UNITS, ETC.) AND CONNECTED TO THE NEAREST STORM WATER PIPE/DRAIN
LOCATION. PROVIDE CLEAN OUT AT EACH ELBOW. SIZE PER MANUFACTURER.
PATCH AND SEAL ALL REMAINING OPENINGS (NEW AND EXISTING) THROUGH FLOORS, CEILINGS, WALLS, AND ROOF RESULTING FROM DEMOLITION OR NEW WORK WITH MATERIALS AND FINISHES TO MATCH EXISTING
CONSTRUCTION AND FIRE RATING.
CONTRACTOR SHALL VISIT THE SITE AND VERIFY EXISTING CONDITIONS PRIOR TO THE BEGINNING OF ANY WORK.
FAILURE TO VISIT THE SITE SHALL IN NO WAY RELIEVE THE CONTRACTOR FROM ANY RESPONSIBILITY.
CONTRACTOR SHALL USE CARE WHEN PERFORMING SELECTIVE DEMOLITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO BUILDING FINISHES, EQUIPMENT, FURNITURE, STRUCTURE, AND MECHANICAL/ELECTRICAL SYSTEMS AND EQUIPMENT. SHOULD ANY DAMAGE OCCUR THE CONTRACTOR SHALL RESTORE DAMAGED AREA/ITEMS TO ORIGINAL CONDITION TO MEET THE OWNER'S SATISFACTION.
CONTRACTOR SHALL NOTIFY AND COORDINATE WITH THE OWNER ANY UTILITY OUTAGES. OWNER SHALL BE GIVEN
A MINIMUM OF 72 HOURS NOTICE (THREE WORKING DAYS) FOR ANY OUTAGES.
WHERE PIPING PENETRATES CONCRETE WALL PROVIDE GROUND PENETRATING RADAR (GPR) SCAN TO IDENTIFY
THE LOCATION OF REBAR. SUBMIT RESULTS TO OWNER AND ENGINEER FOR REVIEW.
CONTRACTOR SHALL SUBMIT COORDINATION SHOP DRAWINGS FOR REVIEW AND APPROVAL PRIOR TO
COMMENCEMENT OF WORK.
MECHANICAL LEGEND
CO
BWV
CHECK VALVE
BALL VALVE
GATE VALVE
BACKWATER VALVE
PIPING CAP
UNION
PIPE SLEEVE
TEE
PIPING ELBOW UP
PIPE CONNECTION BOTTOM
PIPE CONNECTION TOP
WALL CLEANOUT
PIPING ELBOW DOWN
REFRIGERANT SUCTION RS
REFRIGERANT LIQUID
CONDENSATE DRAIN LINE
STORM WATER PIPING
SANITARY PIPING
PUMPED DISCHARGE
WATER LEAK DETECTOR
THERMOSTAT
W
LIMIT OF DEMOLITION
CONNECT TO EXISTING
T
RL
CD
SW
PD
OIL PROBE
ELEVATOR SUMP PIT
(MIN SIZE 2' x 2' x 2')
GRATE COVER
UNION
SHUT-OFF
BALL VALVE
ELEVATOR
SHAFT
JUNCTION BOX
PUMP ON FLOAT
SWITCH
SUBMERSIBLE SUMP PUMP
2" PUMP DISCHARGE
HIGH LEVEL ALARM FLOAT SWITCH
MOUNTED ON DISCHARGE PIPE
CHECK VALVE
PROVIDE ALL PROBE CABLES,
POWER CABLES & ALARM CABLES
AS REQUIRED
ELEVATOR
MACHINE ROOM
CONTROL PANEL. PROVIDE STATUS/
ALARM INTERFACE WITH BUILDING
ENERGY MANAGEMENT SYSTEM
2" PUMP DISCHARGE COORDINATE
LOCATION OF PIPING WITH ELEVATOR
INSTALLER AND EQUIPMENT
NOTES: 1. REFER TO FLOOR PLANS FOR EXACT LOCATION.
2. COORDINATE ALL PIPING, VALVES, JUNCTION BOXES, AND ALL ASSOCIATED
APPURTENANCES WITH AN ELEVATOR INSTALLER AND EQUIPMENT.
3. PUMP, OIL PROBE AND ACCESSORIES SHALL BE "OIL MINDER CONTROL
SYSTEM" AS MANUFACTURED BY STANCOR, OR EQUIVALENT AND SHALL
COMPLY WITH 2000 ASME A-17.1 SAFETY CODE FOR ELEVATORS AND
ESCALATORS.
ELEVATOR SUMP PUMP DETAIL
ELEVATOR SUMP PUMP SCHEDULE
DESIGNATION: ESP-1
SERVICE: ELEVATOR PIT SUMP PUMP
DESCRIPTION: ASME A-17.1 RATED SUBMERSABLE
ELEVATOR SUMP PUMP WITH FLOAT
SWITCH CONTROLS AND OIL MINDER
PROBE WITH ALARM, LIGHT AND
REMOTE MONITORING CIRCUIT.
CAPACITY: 100 GPM @ 9 GPM
1 HP, 3500 RPM
ELECTRICAL: 120V / 1 PH / 60 HZ, 12 FLA
BASIS OF DESIGN: STANCOR OIL MINDER MODEL No SE-100
ATC GENERAL NOTES:
1.
2.
3.
4.
5.
THE EXISTING BUILDING AUTOMATION SYSTEM (BAS) IS FROM TRANE CONTROLS. CONTACT:
TRANE BRANCH OFFICE - PITTSBURGH PA
JULIA LUTHI
OFFICE PHONE: 412-747-4571
THE ATC SCOPE SHALL INCLUDE ALL PROVISIONS TO ACCOMPLISH THE CONTROL SEQUENCES AND FUNCTIONS INCLUDED ON THE DRAWINGS AND IN THE SPECIFICATIONS. THE ATC CONTRACTOR SHALL PROVIDE ALL WIRING, DEVICES, CONTROLLERS AND PROGRAMMING REQUIRED FOR COMPLETE INSTALLATION.
THE ATC CONTRACTOR SHALL UPDATE THE EXISTING BAS GRAPHICS TO REFLECT THE REMOVAL, MODIFICATION, AND/OR ADDITIONS OF EQUIPMENT, DEVICES, POINTS, ETC. INCLUDED UNDER THIS PROJECT.
ALL ATC WIRING SHALL BE INSTALLED IN CONDUIT.
THE ATC SCOPE SHALL INCLUDE THE DEMONSTRATIONS AND TRAINING REQUIRED IN THE SPECIFICATIONS.
ELEVATOR MACHINE ROOM -
SEQUENCE OF OPERATION, MONITORING & CONTROLS:
SPLIT-SYSTEM AIR CONDITIONING UNIT (HEAT PUMP):
THE SYSTEM SHALL BE PROVIDED WITH A REMOTE SPACE TEMPERATURE CONTROLLER TO OPERATE THE
SYSTEM AS FOLLOWS:
SPACE CONTROLLER SHALL CYCLE THE OUTDOOR UNIT AND ASSOCIATED INDOOR UNIT TO MAINTAIN THE
ROOM TEMPERATURE SETPOINT AS FOLLOWS:
COOLING: 77°F (ADJUSTABLE)
HEATING: 60°F (ADJUSTABLE)
SPLIT-SYSTEM AIR CONDITIONING UNIT SHALL BE CONNECTED TO THE BAS. BAS SHALL INCLUDE GRAPHIC OF
UNIT AND MONITOR EQUIPMENT STATUS.
DEDUCT ALTERNATE#1: PROVIDE BREAKOUT COST FOR CONNECTION OF SPLIT-SYSTEM SYSTEM TO THE
BAS.
SEPARATE DDC SENSOR:
THE ATC CONTRACTOR SHALL PROVIDE A SEPARATE DDC SENSOR TO MONITOR SPACE TEMPERATURE AND INITIATE LOCAL AND REMOTE ALARMS IN THE EVENT THE SPACE TEMPERATURE EXCEEDS 95°F. DDC
SENSOR FOR MONITORING AND ALARM IS REQUIRED WITH LOCAL CONTROL LOOP.
ELEVATOR PIT SUMP PUMP:
THE PIT SUMP PUMP CONTROL PANEL SHALL BE CONNECTED TO THE BAS TO MONITOR EQUIPMENT
STATUS.
ELEVATOR EQUIPMENT:
THE ELEVATOR CONTROL PANEL (PROVIDED BY ELEVATOR VENDOR) SHALL BE CONNECTED TO THE BAS TO
MONITOR ELEVATOR OPERATION AND EQUIPMENT STATUS.
REFER TO ELEVATOR CONSULTANT & VENDOR DOCUMENTS FOR ELEVATOR EQUIPMENT INFORMATION.
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED ENGINEER
UNDER THE LAWS OF THE STATE OF PENNSYLVANIA, LICENSE
NUMBER , EXPIRATION DATE
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTING ENGINEERING
6300 BLAIR HILL LANE, SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
ROBERT L. SEYMOUR & ASSOCIATES, INC.
VERTICAL TRANSPORTATION CONSULTANTS
182 THOMAS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BKM# 18025.01
180101D
503-18-102
PE048019R 09/30/2019
BID DOCUMENTS
FULLY SPRINKLERED
MECHANICAL LEGEND,
ABBREVIATIONS &
GENERAL NOTES
REPLACE HYDRAULIC
ELEVATORS
CMP CMP
6/27/2019
M001
DUCTLESS SPLIT SYSTEM AIR CONDITIONING UNIT SCHEDULE
DESIGNATION
AREA SERVED CFM UNIT TYPE REFRIGERANT
TYPE
COOLING HEATING
TOTAL
MBH
ELECTRICAL DATA BASIS OF DESIGN
REMARKSINDOOR
UNIT
OUTDOOR
UNIT
TOTAL
MBH
INDOOR UNIT OUTDOOR UNIT MANUFACTURER MODELVOLTAGE PHASE MCA VOLTAGE PHASE MCA MOCP
AC-1 CU-1 ELEVATOR MACHINE RM
BE011
920 WALL-MOUNT R-410A 36.0 38.0 208 1 1.0 208 1 25.0 31 MITSUBISHI MR
SLIM
PKA-A36KA7 / PUZ-A36NKA7 -
NOTES:
1. PROVIDE DOUBLE SUCTION REFRIGERANT PIPING RISERS AND TRAPS AS RECOMMENDED BY MANUFACTURER. QUANTITY AND SIZES OF REFRIGERANT PIPING SHALL BE AS RECOMMENDED BY MANUFACTURER.
2. PROVIDE INDOOR UNIT WITH CONDENSATE PUMP.
3. INDOOR UNIT SHALL BE POWERED BY THE OUTDOOR UNIT. THE INDOOR UNIT AND OUTDOOR UNIT SHALL EACH BE PROVIDED WITH A DISCONNECT SWITCH.
4. COOLING CAPACITY INDICATED BASED ON INDOOR: 80°F DB / 67°F WB; OUTDOOR: 95°F DB / 75°F WB. CAPACITY INDICATED IS MINIMUM SYSTEM CAPACITY AND SHALL BE MET AFTER ANY CORRECTION OR DE-RATING FACTOR BASED ON
SYSTEM INSTALLATION AND REFRIGERANT ROUTING.
5. PROVIDE FOR LOW AMBIENT OPERATION DOWN TO 0°F.
6. SPLIT-SYSTEM AIR CONDITIONING UNIT SHALL BE CONNECTED TO THE BAS. BAS SHALL INCLUDE GRAPHIC OF UNIT AND MONITOR EQUIPMENT STATUS. PROVIDE UNIT WITH BACNET CARD FOR INTEGRATION TO BAS.
T T
DRAWING NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
REMOVE EXISTING DAMPER AND DUCTWORK AT WALL PENETRATION.
WALL TO BE INFILLED UNDER ARCHITECTURAL DIVISION. REMOVE
DUCTWORK AS REQUIRED FOR INFILLING OF WALL (ASSUME 5 FEET).
REMAINING CONNECTED DUCTWORK SHALL BE ABANDONED FOR
REMOVAL UNDER SEPERATE PROJECT.
RX SIDEWALL SUPPLY GRILLE (36"x12" @ 48" AFF).
RX SIDEWALL EXHAUST GRILLE (30"x32" @ 65" AFF).
PROVIDE WALL-MOUNTED AIR CONDITIONING UNIT. INSTALL UNIT ABOVE
DOOR. PROVIDE CONDENSATE DRAIN PUMP.
SIZE AND ROUTE RS/RL PIPING PER THE MANUFACTURER'S
REQUIREMENTS. PROVIDE RS PIPING WITH 1.5" FLEXIBLE ELASTOMERIC
CELLULAR THERMAL INSULATION.
ELEVATOR SUMP PUMP & ASSOCIATED CONTROL PANEL PROVIDED BY
PLUMBING CONTRACTOR. COORDINATE CONNECTIONS BETWEEN
ELEVATOR CONTROL PANEL AND BUILDING AUTOMATION SYSTEM (BAS).
REMOVE EXISTING LOUVER AND DAMPER (46"x20") AT WALL
PENETRATION AT TOP OF ELEVATOR HOISTWAY. LOUVER IS LOCATED
ABOVE CEILING OF 3RD FLOOR ELEVATOR LOBBY. WALL PENETRATION
TO BE INFILLED UNDER ARCHITECURAL DIVISION. REMOVE ASSOCIATED
CONTROL WIRING.
PROVIDE SEPERATE DDC SENSOR TO MONITOR SPACE TEMPERATURE
AND INITIATE LOCAL AND REMOTE ALARM AT BAS.
GENERAL NOTES:
1. REFER TO SHEET M001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND
GENERAL NOTES.
BE01B
BE01C
BE01A
BE01
EB
BE01O
BE01N
1G17
BE01D
BE01E
BE01G
BE01F
BE01M
BE01L
BE01I
BE01H
BE01J
BE01K
RS/RL UP TO CONDENSING UNIT
EX
TE
R
IO
R S
TA
IR
W
EL
L U
P METAL PLATFORM ABOVE
AC-1
PART PLAN - 3RD FLOOR ELEVATOR LOBBY
REFER TO 3RD FLOOR ELEVATOR LOBBY
PART PLAN THIS SHEET
SERVES AC-1
KEY PLAN
AREA OF WORK
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED ENGINEER
UNDER THE LAWS OF THE STATE OF PENNSYLVANIA, LICENSE
NUMBER , EXPIRATION DATE
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
MECHANICAL / ELECTRICAL
CONSULTING ENGINEERING
6300 BLAIR HILL LANE, SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
ROBERT L. SEYMOUR & ASSOCIATES, INC.
VERTICAL TRANSPORTATION CONSULTANTS
182 THOMAS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BKM# 18025.01
180101D
503-18-102
PE048019R 09/30/2019
BID DOCUMENTS
FULLY SPRINKLERED
BASEMENT FLOOR PLAN
MECHANICAL
REPLACE HYDRAULIC
ELEVATORS
CMP CMP
6/27/2019
MH101
BASEMENT ROOM LIST NEW
1G17 Space
BE01 STORAGE, EQUIPMENT
BE01A STORAGE, FILE RM / CAGE
BE01B MECHANICAL ROOM
BE01C ELEVATOR PIT
BE01D POLICE TRAINING
BE01E STORAGE, GENERAL / CAGE
BE01F MECHANICAL ROOM
BE01G DAV STORAGE / CAGE
BE01H STORAGE, EQUIPMENT / CAGE
BE01I MECHANICAL ROOM
BE01J ELEVATOR PIT
BE01K STORAGE, EQUIPMENT / CAGE
BE01L STORAGE, GENERAL / CAGE
BE01M STORAGE, EQUIPMENT / CAGE
BE01N STORAGE, GENERAL / CAGE
BE01O STORAGE, EQUIPMENT / CAGE
EB STAIR
SCALE: 1/8" = 1'-0"
4'-0" 8'-0"0 16'-0"
PROJECT NORTH
TRUE NORTH
SCALE: 1/8" = 1'-0"
1 BASEMENT PLAN - MECHANICAL - NEW WORK
DRAWING NOTES:
2.
CONDENSING UNIT MOUNTED ON WALL. PROVIDE WALL BRACKETS
FOR MOUNTING.
SIZE AND ROUTE RS/RL PIPING PER THE MANUFACTURER'S
REQUIREMENTS. PROVIDE RS PIPING WITH 1.5" FLEXIBLE
ELASTOMERIC CELLULAR THERMAL INSULATION.
GENERAL NOTES:
1. REFER TO SHEET M001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND
GENERAL NOTES.
1F69
1F69A
1F68 1F66 1F64
1F61
1F72
1F70
1F2
1F73
1F71
E1
1F59
1F57
1F56
1F55
1F46
1F60 1F62
1F631F651F67
1F53B
1F58
1F541F49
1F53A
1F51 1F53
1F10
1F10E
1F10D
1F52
1F10C
1F50
1F48
1F441F48A
1F47
1F10A
1F10B
1F45
1F43
1F4245
1F74
1G2
1F09
P7A
P6A 1F1
1G09
EX CONDENSING UNITS
(ABV STAIRWELL)
RS/RL DN
EX
TE
R
IO
R S
TA
IR
W
EL
L D
N
EX METAL PLATFORM
CU-1
KEY PLAN
AREA OF WORK
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
I CERTIFY THAT THESE DOCUMENT WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A DULY LICENSED ENGINEER
UNDER…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .