This is a Scope of Work document from the City of Watsonville, California for exterior painting services at the Civic Plaza Building located at 275 Main Street, Watsonville, CA 95076. The project encompasses comprehensive exterior painting and stucco repair of the municipal building, which is connected to a parking garage featuring a tile mosaic art installation that will remain unpainted. The contractor must provide all labor, materials, equipment, and supervision to complete the work in accordance with specified standards and match the existing exterior color scheme. Work includes painting all exterior walls and trim, under-eaves, gutters, downspouts, conduit, metal stairs and rails, stairwell enclosures, elevator enclosures, metal overhangs, exposed stucco flashing, and trash enclosure structures. The project explicitly excludes painting overhead lighting structures, door handles, kickplates, windows, unpainted water spigots, electrical outlets, power equipment, patio structures not connected to the building, exterior tile or flooring, exterior artwork, and signage. The document does not specify response dates, bid due dates, site visits, or bidder conferences.
The scope requires surface preparation including cleaning, washing, scraping, sanding, and repair of all defects identified in attached sketches and photos, with additional defects discovered during preparation requiring prior City approval before proceeding. The contractor must use waterproof and mold-resistant paint with a minimum of two coats (prime and finish) applied in accordance with manufacturer instructions. Three acceptable paint products are specified: Dunn Edwards Enduralastic 10 Elastomeric Wall Coating, Benjamin Moore Ultra Spec Masonry Elastomeric Waterproof Coating, or Sherwin Williams ConFlex SherLastic Elastomeric Coating, though the City reserves the right to reject equivalent products not approved. All stucco patching materials, joint compounds, and repair products require City approval prior to application. The contractor is responsible for maintaining public safety, managing traffic control if lane closures are necessary, protecting landscaping and adjacent surfaces from materials and overspray, and minimizing disruption to building tenants. No specific pricing, funding sources, or contract term information is provided in the document.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXTERIOR PAINTING OF CIVIC PLAZA BUILDING
Located at 275 Main Street
SCOPE OF WORK
The City is seeking bids for exterior painting of its existing Civic Plaza
Building located at 275 Main Street, Watsonville, CA 95076. The building is connected to a parking garage that is mostly covered in a tile mosaic art installation which will not be painted. Exterior shall be painted to match the existing color scheme. Specific color sample matches shall be submitted and approved by the City with selected contractor. The selected contractor shall provide all labor, materials, equipment, and supervision necessary to complete the project which includes but is not limited to the following specifications:
1. Work Specifications
a. Contractor is responsible for ensuring a safe worksite for their own workers and the public accessing the building in accordance with all applicable CalOSHA requirements. Contractor shall provide equipment that will not block building entrances and maintains safe walkways for public safety. Contractor activities shall not interfere with building tenants and/or businesses.
b. Protection Measures: Contractor shall safeguard landscaping, walkways, and adjacent surfaces from preparation/washing materials, stucco repair materials, paint droplets, overspray, or other such spills.
c. Work shall be executed in a manner that minimizes disruption to traffic. If partial lane closure is required, contractor shall prepare and submit a traffic control plan that meets at a minimum the requirements of the California Manual of Uniform Traffic Control
Devices (MUTCD) for review and approval by the City.
d. Surface Preparation: Perform cleaning, washing and preparation of all surfaces to receive paint and coating as instructed by the product manufacturer. Correct any defects, clean surfaces, and remove or repair existing coatings that exhibit defects (scrape, sand, patch, etc.). Screw fasteners (not nails) shall be used if any fasteners are needed to correct defects.
e. Stucco patching materials, joint compounds, patch resolution and fastener head cover materials if needed shall be submitted for approval by the City. Surface preparation and application of approved repair product shall be completed as instructed by the product manufacturer.
f. Repair all large and small stucco defects identified in the attached sketches and photos. If additional defects are found during the surface preparation process, notify the City of the additional areas prior to proceeding with repair so total actual quantities can be documented and paid. No compensation will be made for additional repairs not previously approved by the City unless otherwise agreed in writing.
g. Paint type shall be waterproof and mold resistant. Contractor shall furnish paint with mold proof or resistant properties or additives.
h. There shall be a minimum of two coats of paint or coatings (prime
& finish). Skilled workers in accordance with manufacturer’s instructions shall perform application. Material shall only be applied when moisture and temperature levels are within manufacturer’s instructions and recommendations. The City has met with the following paint manufacturers who recommended the following products for this particular exterior building application. The following are acceptable paint products, though the City will consider equivalent products from a different manufacturer. The listed manufacturer spec sheets are attached to this document.
1. Dunn Edwards Enduralastic 10 Elastomeric Wall Coating
2. Benjamin Moore Ultra Spec Masonry Elastomeric Waterproof
Coating
3. Sherwin Williams ConFlex SherLastic Elastomeric Coating
It is at the bidder’s risk to base their bid pricing on an “or equal” product not included in this list, and the City reserves the right to not approve a product that in its sole opinion is not equivalent, and no adjustment to bid price will be made therefor.
i. Remove or tape all electrical plates, hardware, light fixture trim, signage, or other unpainted surfaces prior to preparing surfaces for finishing. Any removed plates, fixtures, etc. shall be replaced, and all tape shall be removed after painting has been completed.
Any removable bulletin boards or padding shall be removed prior to painting and then replaced.
j. Apply products in accordance with manufacturer’s instructions. Apply each coat to uniform appearances.
2. Exterior Areas To Be Painted
a. All Painted Walls And Trim
b. All Under-Eaves
c. All Gutters And Downspouts
d. All Painted Conduit
e. Two top story metal stairs and rails
f. Top story facing parking structure exterior, breezeway, stairwell enclosures, and elevator enclosures
g. All metal overhangs at four locations
h. Top story exposed stucco flashing (see repair photos)
i. Trash Enclosure Structure Interior and Exterior
j. Exterior Transformer and Standby Generator (coating material to match existing and be applied per manufacturer recommendations)
3. Do Not Paint
a. Overhead Lighting Structures
b. Door Handles And Kickplates
c. Windows
d. Water Spigots Not Already Painted
e. Electrical Outlets
f. Power Equipment, Panels And Wiring Channels Not Already Painted
g. Patio Structures Not Connected To Building (i.e. library patio facility)
h. Exterior tile or flooring
i. Exterior Artwork
j. Exterior Signage
Stucco Repair Area Photos
CONFORMS TO:
• ARB 2007/2020 SCM & CALGreen 2022
• LEED v4/4.1
• SCAQMD Rule 1113
• CA Extended Producer Responsibility
• MIR, HPD
AIRLESS SPRAY BRUSH ROLLER
PRESSURE:
1800-2500 psi
TIP: .019”-.021”
Nylon/Polyester ½” - 1½” nap
12/25 (03/25)
SAFETY DATA SHEET: Available at www.dunnedwards.com
SURFACE PREPARATION: All surfaces must be cured, clean, dry, and free from dirt, dust, rust, stains, grease, oil, mildew, wax, efflorescence, bond-breakers, and other contaminants. Remove all loose, peeling, or chalky paint by sanding, scraping, or other appropriate methods. Repair all cracks, holes, and other surface imperfections with a suitable patching material. Repaired surfaces should then be sanded smooth and dusted clean. Glossy surfaces should be dulled to provide a roughened surface for good adhesion.
SPECIAL INSTRUCTIONS
• � CAUTION! Scraping or sanding surfaces of older buildings (especially pre-
1978) may release dust containing lead or asbestos. EXPOSURE TO LEAD OR ASBESTOS CAN BE VERY HAZARDOUS TO YOUR HEALTH. Wear a NIOSH-approved N100 particulate filter mask to avoid breathing dust. Use a HEPA vacuum for cleanup, and finish by water-washing all surfaces. For more information, see Dunn-Edwards brochure on “Surface Preparation Safety”or call U.S. EPA’s lead hotline at 1-800-424-LEAD, or visit www.epa. gov/lead or / asbestos, or contact your state or local Health Agency.
• � This product can neither cause nor prevent or cure the growth of mold, mildew, or other forms of fungus. Excessive moisture and inadequate ventilation are the main conditions that promote their growth. Correct any such conditions before painting.
• � If efflorescence exists, remove all noticeable deposits and prime the entire surface with SUPER-LOC® Premium (SLPR00), EFF-STOP® Select (ESSL00) or FLEX-PRIME® Select (FPSL00).
• � For wood application, prime with EZ-PRIME® Premium (EZPR00) and then apply two coats of ENDURALASTIC 10 (EDLX10) at a maximum dry film thickness of 1.5 to 3.0 mils per coat. Add up to 1/4 pint (4 fl. oz.) of clean water per gallon of coating. Do not apply at the recommended dry film thickness for masonry of 11-13 mils, as it can create moisture related issues.
• � Certain woods, such as redwood, cedar, and spruce, contain water-soluble extracts (tannins) that may discolor lighter colors. In these situations, it is recommended to prime the wood with EZ-PRIME® Premium (EZPR00) before applying ENDURALASTIC 10 (EDLX10).
• � Airless spray application of ENDURALASTIC 10 (EDLX10) must be “pinholefree” and have a dry film thickness of 11–13 mils. Surface features mandate the method of application and number of coats needed to achieve this.
| • | � Do not thin or reduce. |
| • | � Do not apply when the air or surface temperature is below 50ºF. |
| • | � While we recommend applying our exterior latex paints within industry standard |
temperature ranges, they can be applied at temperatures up to 120°F. Refer to www.dunnedwards.com/technical-bulletins/ for more information.
SOLVENT TYPE: Waterborne RESIN TYPE: 100% acrylic
FINISH (ASTM D 523): Flat: 4.0–5.0% on a 60º meter; 3.0–7.0% on an 85º meter
COLORS: All colors can be special ordered or store mixed.
TINT BASES: L Tintable White, M Medium, U Ultra Deep
VISCOSITY@77ºF/25ºC (ASTM D 562): 125–140 KU
MAXIMUM VOC CONTENT
50 g/L (as supplied)
MAXIMUM RAVOC (Reactivity-Adjusted VOC) 25 g/L
SOLIDS BY VOLUME (ASTM D 2697)
50.1% ± 2%
SOLIDS BY WEIGHT
63.8% ± 2%
WEIGHT PER GALLON (ASTM D 1475): 11.15 lbs.
COMPOSITION BY WEIGHT
Pigment–38.2%
*Prime pigments....................................8.3 Reinforcing pigments.........................29.9
Vehicle–61.8% Resin solids........................24.0 Water & additives...............37.8
*Prime pigments include titanium dioxide (TiO²), plus all other pigments directly adding to the hiding power of this paint.
RECOMMENDED FILM THICKNESS PER COAT
Wet: 22-26 mils Dry: 11-13 mils
PERFORMANCE SPECIFICATION
Tensile Strength: 215 PSI | ASTM D2370-10 Elongation: 330% Wind Driven Rain: PASS | ASTM D6904-03 Permeability: 13.0 | ASTM D1653-03
PRACTICAL COVERAGE PER COAT AT RECOMMENDED DRY FILM THICKNESS
Approximately 25–75 sq. ft. per gallon, depending on surface conditions and application techniques.
THINNING RECOMMENDATION: This coating is intended to be applied without thinning or diluting.
AVERAGE DRY TIME@77ºF/25ºC (ASTM D 1640)
To touch: 1–2 hours Recoat: 24 hours Dry times and recoat times are temperature, humidity and film thickness dependent.
APPLICATION EQUIPMENT: Airless spray
PACKAGING: Five-gallon containers
STORAGE: Store in a dry area. Protect from freezing. Protect from temperatures above 110ºF for extended periods of time. Extreme temperatures may cause paint to become unusable. See Paint Storage Best Practices Technical Bulletin at dunnedwards.com for more information.
CLEANUP: Warm, soapy water
DISPOSAL: For information on local options to dispose of unwanted leftover paint, call Dunn-Edwards Customer Service at 1-888-DEPAINT or visit www.dunnedwards.com. Do not mix with other products.
PRODUCT INFORMATION
DUNN-EDWARDS CORPORATION • 520 S. 67th Ave, Phoenix, AZ 85043 USA • (888) DEPAINT® I dunnedwards.com 337-2468
ENDURALASTIC® 10 is an ultra-premium specialty 100% acrylic elastomeric wall coating designed for use on exterior surfaces. ENDURALASTIC 10 has exceptional flexibility, chalking and dirt pick-up resistance, bridges hairline cracks, and provides outstanding waterproofing protection against wind-driven rain. ENDURALASTIC 10 also provides excellent adhesion and outstanding alkali and efflorescence resistance on properly prepared masonry.
ENDURALASTIC® 10
Elastomeric Wall Coating
EDLX10
INHIB
ITORMILDE
W
PRODUCT INFORMATION
PRIMERS
MASONRY
Plaster:
Stucco (new):
Stucco (repaint):
Tilt-up concrete:
Poured-in-place:
Brick:
Smooth trowel:
SUPER-LOC® Premium (SLPR00), EFF-STOP® Premium (ESPR00), EFF-STOP® Select (ESSL00) or FLEX-PRIME® Select (FPSL00)
Concrete block: Smooth BLOCFIL™ Premium (SBPR00) or Smooth BLOCFIL™ Select (SBSL00)
METAL
Ferrous:
BLOC-RUST® Premium (BRPR00) or ENDURAPRIME® Acrylic Rust Preventative Metal Primer (ENPR00)
Non-ferrous:
ENDURAPRIME® Galvanized Metal Primer [Formerly ULTRASHIELD® Galvanized Metal Primer (ULGM00)] BLOC-RUST® Premium (BRPR00) or SUPER-LOC® Premium (SLPR00)
Galvanized steel:
ENDURAPRIME® Galvanized Metal Primer [Formerly ULTRASHIELD® Galvanized Metal Primer (ULGM00)] or *ULTRA-GRIP® Premium (UGPR00)
*for incidental use on galvanized
HEALTH & SAFETY CAUTIONS! INHALATION OF SPRAY MIST OR SANDING
DUST MAY BE HARMFUL. Use only with adequate ventilation. Avoid breathing vapors, spray mist and sanding dust. Wear NIOSH-approved N100 particulate filter mask when spraying or sanding. Avoid contact with skin and eyes. Do not ingest. Close container after each use. FIRST AID: If swallowed, immediately give 1 or 2 glasses of water to drink – for emergency information, call 1-800-222-1222.
If having difficulty breathing, move to fresh air. For eye contact, immediately flush with water for 15 minutes. For skin contact, wash thoroughly with soap and water.
• KEEP OUT OF REACH OF CHILDREN •
Ingredient (CAS #): Water (7732-18-5); Aluminosilicates (68476-25-5/37244-96- 5);
Copolymer Resin (Proprietary); Titanium Dioxide (13463-67-7); Ester Alcohol (25265-77-4); Benzophenone (119-61-9); Quartz (14808-60-7).
WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov
12/25 (03/25)
PRODUCT INFORMATION
DUNN-EDWARDS CORPORATION • 520 S. 67th Ave, Phoenix, AZ 85043 USA • (888) DEPAINT® I dunnedwards.com 337-2468
INHIB
ITORMILDE
W
ENDURALASTIC® 10
Elastomeric Wall Coating
EDLX10
Ultra Spec® Masonry Elastomeric Waterproofing Coating
Low Lustre 360
Benjamin Moore & Co., 101 Paragon Drive, Montvale, NJ 07645 Tel: (201) 573-9600 www.benjaminmoore.com 360 US 111424
General Description
A high-build, flexible 100% acrylic coating. When applied as directed, up to 20 mils wet film thickness, this product bridges minor surface imperfections, provides outstanding durability, and offers long lasting protection.
• 300% elongation
• Bridges cracks up to 1/32”
• Breathable finish allows interior moisture to escape without damage to the film
• Provides a waterproof finish that protects structures from moisture damage
• Provides a mildew-resistant finish
• Low lustre finish stays clean longer
Usage
For use on exterior uncoated or new masonry and previously painted surfaces such as smooth stucco, concrete/cinder block, fiber cement siding, pre-cast concrete, poured in place concrete, and tilt-up construction.
Colors White (01) Bases 1X, 2X, 3X & 4X Colorant System Gennex®
Technical Data
Vehicle 100% Acrylic
Pigment Titanium Dioxide
Volume Solids 44 ± 2%
Spread Rate Per Gallon 80 – 100 Sq. Ft.
Recommended Film Thickness
Wet: 16.0 – 20.1 mils
Dry: 7.1 – 8.8 mils
Depending on surface texture and porosity. Be sure to estimate the right amount of paint for the job. This will ensure color uniformity and minimize the disposal of excess paint.
Dry Time @ 77 °F
(25 °C) @ 50% RH
To Touch: 2 hours
To Recoat: 12 hours
Painted surfaces can be washed after two weeks. High humidity and cool temperatures will result in longer dry, recoat and service times.
Surface Temperature During Application
Min: 50 °F
Max: 100 °F
Viscosity 122 ± 4 KU
Flash Point None
Sheen / Gloss 5 – 10 @ 60°
Clean Up Water
Thinner refer to page 2
Weight Per Gallon 11.2 lbs.
Storage Temperature
Min: 40 °F
Max: 90 °F
VOC < 100 g/L
Primer Systems
Achieving a waterproof system requires that the finished coating system fills all the voids in the masonry creating a pinhole free surface and that all transitions between building materials are properly sealed to prevent moisture intrusion. Because building materials and construction design factors vary widely it may be necessary to adjust the spread rate, number of coats or application methods to achieve a waterproof system on your project.
Special Note: Certain custom colors require a Deep Color Base Primer tinted to a special prescription formula to achieve the desired color. Consult your retailer.
Wood, and engineered wood products:
Fresh Start® High-Hiding All Purpose Primer (046)
Bleeding Woods (Redwood, Cedar, etc.):
Fresh Start® Exterior Deck & Siding Primer (094) or Fresh Start® High-Hiding All Purpose Primer (046)
Rough or Pitted Masonry:
Ultra Spec® Masonry Interior/Exterior Hi-Build Block Filler (571)
Poured or Pre-cast Concrete/Fiber Cement Siding:
Ultra Spec® Masonry Interior / Exterior 100% Acrylic Masonry Sealer (608) or Ultra Spec® Masonry High Build Primer (N609)
Ferrous Metal (Steel and Iron):
High Performance Acrylic Metal Primer (HP1100) or High Performance Alkyd Metal Primer (HP1320)
Non-Ferrous Metal (Galvanized & Aluminum):
All new metal surfaces must be thoroughly cleaned with Oil & Grease Emulsifier (HP6000) to remove contaminants. New shiny non-ferrous metal surfaces that will be subject to abrasion should be dulled with very fine sandpaper or a synthetic steel wool pad to promote adhesion. High Performance Acrylic Metal Primer (HP1100)
Limitations
• Do not apply when air or surface temperatures are below 50 °F.
• Do not apply if rain or threatening weather is expected within 24 hours.
Compliance & Certifications
OTC ✓
OTC II ✓
CARB ✓
CARB07 ✓
CARB19 ✓
UTAH ✓
AZMC ✓
SCAQMD ✓
ASTM D6904
Wind Driven Rain
Pass: (< 0.2)
2 coats (20 mils WFT per coat) over CMU 360
ASTM D1653
Water Vapor Permeance
38 perms
ASTM D3273/D3274
Mildew Resistance Test
Pass: No Growth
ASTM D2370 Elongation & Tensile Strength
300 %
520 PSI
Technical Assistance
Available through your local authorized independent Benjamin Moore retailer.
call 1-866-708-9180 visit www.benjaminmoore.com http://www.benjaminmoore.com/
Ultra Spec® Masonry Elastomeric Waterproofing Coating – Low Lustre 360
Benjamin Moore & Co., 101 Paragon Drive, Montvale, NJ 07645 Tel: (201) 573-9600 www.benjaminmoore.com 360 US 111424 Benjamin Moore, Fresh Start, Gennex, Ultra Spec, and the triangle “M” symbol are registered trademarks, licensed to Benjamin Moore & Co.
All other marks are the property of their respective owner. ©2016, 2024 Benjamin Moore & Co. All rights reserved
Surface Preparation
Surfaces must be clean, dry and free of oil, grease, wax, rust, mildew, chalk and loose or scaling paint. Cement based waterproofing paints should be removed.
Glossy surfaces must be dulled. Un-weathered areas such as eaves, porch ceilings, overhangs and protected wall areas should be washed with an appropriate cleaner and rinsed with a strong stream of water from a garden hose or power washer to remove contaminants that can interfere with proper adhesion.
All new masonry surfaces must be power washed or brushed thoroughly with stiff fiber bristles to remove loose particles. For optimal system performance new masonry should cure 30 days prior to application of the sealer / coating system and have a pH of 10 or less. If project timelines require an expedited system; masonry that has been allowed to cure for 7 days under normal drying conditions and has a pH of 13 or less may be sealed with Ultra Spec® Masonry Interior / Exterior 100% Acrylic Masonry Sealer (608) or Ultra Spec® Masonry High Build Primer (N609) prior to finishing. Poured or pre-cast concrete with a very smooth surface should be etched or abraded to promote adhesion, after removing all form release agents and curing compounds.
Ultra Spec® Masonry Elastomeric Coating will bridge cracks up to 1/32”. Cracks between 1/32” – 1/16” in width should be filled with caulk and over coated with a brush or knife grade elastomeric patch to provide the required joint movement. Cracks larger than 1/16” should be routed out to 1/4” by 1/4” and repaired as directed with the caulk and patch products prior to finishing.
Difficult Substrates: Benjamin Moore offers a number of specialty primers for use over difficult substrates such as bleeding woods, grease stains, crayon markings, hard glossy surfaces, or other substrates where paint adhesion or stain suppression is a particular problem. Your Benjamin Moore® retailer can recommend the right problem-solving primer for your special needs.
Application
Apply by brush, roll, power roller or spray and back roll, working the material into the surface to fill all cracks and voids. Strike off roller applications in a downward direction to ensure a uniformly stippled finish. Apply one or two coats as required to properly encapsulate the substrate. Monitor spread rate or check wet film thickness repeatedly during application to ensure proper wet and dry film thicknesses are achieved.
Because it is applied in very heavy coats, Ultra Spec® Masonry Elastomeric Waterproof Coating will remain sensitive to rain and moisture condensation longer than conventional coatings. Make sure to leave ample drying time between application of the coating and exposure to moisture.
Brush: Nylon / polyester Roller: Premium Quality
Spray, Airless:
Pressure / 2,500 – 3,000 PSI Tip / 0.021 – 0.031
Thinning/Cleaning
Conditioning with Benjamin Moore® 518 Extender may be necessary under certain conditions to adjust open time or spray characteristics.
Add 518 Extender or water - Max of 8 fl. oz. to a gallon paint Never add other paints or solvents.
Clean Up: Wash brushes, rollers, and other painting tools in warm soapy water immediately after use. Spray equipment should be given a final rinse with mineral spirits to prevent rusting.
USE COMPLETELY OR DISPOSE OF PROPERLY. Dry, empty containers may be recycled in a can recycling program. Local disposal requirements vary; consult your sanitation department or state-designated environmental agency on disposal options.
Environmental Health & Safety Information
Use only with adequate ventilation. Do not breathe spray mist or sanding dust.
Ensure fresh air entry during application and drying. Avoid contact with eyes and prolonged or repeated contact with skin. Avoid exposure to dust and spray mist by wearing a NIOSH approved respirator during application, sanding and clean up.
Follow respirator manufacturer’s directions for respirator use. Close container after each use. Wash thoroughly after handling.
WARNING! If you scrape, sand, or remove old paint, you may release lead dust.
LEAD IS TOXIC. EXPOSURE TO LEAD DUST CAN CAUSE SERIOUS ILLNESS, SUCH AS
BRAIN DAMAGE, ESPECIALLY IN CHILDREN. PREGNANT WOMEN SHOULD ALSO
AVOID EXPOSURE. Wear a NIOSH approved respirator to control lead exposure.
Clean up carefully with a HEPA vacuum and a wet mop. Before you start, find out how to protect yourself and your family by contacting the National Lead Informational Hotline at 1-800-424-LEAD or log on to www.epa.gov/lead.
WARNING Cancer and Reproductive Harm– www.P65Warnings.ca.gov Refer to the product label & Safety Data Sheet for product specific information.
FIRST AID: In case of eye contact, flush immediately with plenty of water for at least 15 minutes; for skin, wash thoroughly with soap and water. If symptoms persist, seek medical attention. If you experience difficulty breathing, leave the area to obtain fresh air. If continued difficulty is experienced, get medical attention immediately.
IN CASE OF SPILL – Absorb with inert material and dispose of as specified under “Clean up”.
KEEP OUT OF REACH OF CHILDREN
PROTECT FROM FREEZING
Refer to Safety Data Sheet for additional health and safety information.
http://www.epa.gov/lead http://www.p65warnings.ca.gov/
116.16
ConFlex™ SherLastic®
Elastomeric Coating CF16W0051 Extra White, CF16W0053 Deep Base
CHARACTERISTICS
ConFlex™SherLastic® Elastomeric Masonry Coating is a 100% acrylic coating that provides great flexibility, durability, and weather resistance.
This product will protect against wind-driven rain when used on tilt-up, precast, or poured-in-place concrete, CMU, and stucco.
Color: Many Colors 2 coat system, brush, roller, or spray applied, coverage per coat:
107-145 sq. ft. per gallon
Wet mils: 11.0-15.0 Dry mils: 4.3-5.8 1 coat system, spray applied, coverage per coat:
53-72 sq. ft. per gallon
Wet mils: 22.0-30.0 Dry mils: 8.6-11.7
Can be applied up to 30 mils wet.
Coverage will vary with the substrate and the texture.
Drying Schedule @ 50% RH:
@ 77°F
Touch: 4 hours Recoat: 24 hours
Drying time is temperature, humidity, and film thickness dependent.
Finish: 5-10 units @ 85°
Tinting with CCE only:
Base oz.per gallon Strength
Extra White 0-6 SherColor Deep Base 2-12 SherColor
Extra White CF16W0051 (may vary by color)
V.O.C. (less exempt solvents):
less than 50 grams per litre;0.42 lbs. per gallon
As per 40 CFR 59.406 Volume Solids: 39 ± 2% Weight Solids: 53 ± 2% Weight per Gallon: 10.79 lb Flash Point: NA Vehicle Type: 100% Acrylic Shelf Life: 36 months,unopened
Mildew Resistant:
This coating contains agents which inhibit the growth of mildew on the surface of this coating film.
COMPLIANCE
As of 04/07/2020, Complies with:
OTC Yes OTC Phase II Yes SCAQMD Yes CARB Yes CARB SCM 2007 Yes Canada Yes LEED® v4 & v4.1 Emissions N/A LEED® v4 & v4.1 V.O.C. Yes EPD-NSF® Certified N/A MIR-Manufacturer Inventory N/A MPI® Yes
APPLICATION
Temperature:
Apply between 50°-100°F The following is a guide. Changes in pressures and tip sizes may be needed for proper spray characteristics.
Always purge spray equipment before use with listed reducer. Any reduction must be compatible with the existing environmental and application conditions.
Reducer: Do not reduce Airless Spray:
Pressure 2300 p.s.i.
Tip .021 inch Brush: nylon-polyester Roller Cover: ½ to 1½ inch nap synthetic cover.
Avoid over-brushing or rapid rolling, which causes air bubbles.
The substrate and its condition will determine the application procedure.
Considerations to minimize pinholes:
• 2 coat application with overnight drying between coats
• Spray application with backrolling
• Power rolling
APPLICATION TIPS
Sealing and Patching:
After cleaning the masonry surface thoroughly, prime any bare surface with Loxon Concrete & Masonry Primer, apply an elastomeric patch or sealant if needed, allow to dry, then topcoat.
To improve the performance consider:
• Use caution when preparing the substrate to create a uniform surface.
• Patch cracks, crevices, and openings with an elastomeric patch or sealant
• Stripe coat all inside and outside corners and edges with 1 coat of ConFlex SherLastic Elastomeric Masonry Coating.
RECOMMENDED SYSTEMS
A minimum total dry film thickness of 8 - 12 mils of topcoat and a surface with 10 or less pinholes per square foot is required for a waterproofing system.
New Construction Concrete & Stucco:
1 coat Loxon Concrete and Masonry Primer 1-2 coats ConFlex SherLastic Elastomeric
Concrete Block, CMU, Split-face Block:
1-2 coats ConFlex Block Filler or 1-2 coats Loxon Acrylic Block Surfacer 2 coats ConFlex SherLastic Elastomeric (2 coats recommended due to the typical porosity of these surfaces)
Previously Coated:
After power washing, apply 1 coat of Loxon Conditioner to tie any residual chalk to the surface.
1 coat Loxon Acrylic Conditioner (if needed) 1-2 coats ConFlex SherLastic Elastomeric
04/2020 www.sherwin-williams.com continued on back
ConFlex™ SherLastic®
Elastomeric Coating
SURFACE PREPARATION
WARNING! Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may cause brain damage or other adverse health effects, especially in children or pregnant women.
Controlling exposure to lead or other hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local health authority.
Remove all surface contamination by washing with an appropriate cleaner, rinse thoroughly and allow to dry. Scrape and sand peeled or checked paint to a sound surface.
Sand glossy surfaces dull. Seal stains from water, smoke, ink, pencil, grease, etc. with the appropriate primer-sealer. Recognize that any surface preparation short of total removal of the old coating may compromise the service length of the system.
Caulking:
Gaps between windows, doors, trim, and other through-wall openings can be filled with the appropriate caulk after priming the surface.
Cement Composition Siding-Panels:
Remove all dirt, dust, grease, oil, loose particles, laitance, foreign material, and peeling or defective coatings. Allow the surface to dry thoroughly. Primer required. If the surface is new, test it for pH, if the pH is higher than 9, prime with Loxon Concrete and Masonry Primer.
Masonry, Concrete, CMU, Stucco:
Remove all dirt, dust, mildew, loose particles, laitance, foreign material, peeling and defective coatings, chalk, form release agents, moisture curing membranes, etc. All new surfaces must be cured according to the supplier’s recommendations—usually about 30 days. If painting cannot wait 30 days, allow the surface to cure 7 days at 75°F and prime the surface with Loxon Concrete & Masonry Primer or Loxon Block Surfacer to fill Block, and CMU.
On tilt-up and poured-in-place concrete, commercial detergents and sandblasting may be necessary to remove sealers, release compounds, and to provide an anchor pattern. Allow the surface to dry thoroughly.
Primer required. Concrete and mortar must be cured at least 30 days. If painting cannot wait 30 days, allow the surface to cure 7 days at 75°F and prime the surface with Loxon Concrete & Masonry Primer. Fill bugholes, air pockets, cracks, and other voids with an elastomeric patch or sealant. Rough surfaces can be filled to provide a smooth surface.
SURFACE PREPARATION
Mildew:
Prior to attempting to remove mildew, it is always recommended to test any cleaner on a small, inconspicuous area prior to use. Bleach and bleaching type cleaners may damage or discolor existing paint films. Bleach alternative cleaning solutions may be advised.
Mildew may be removed before painting by washing with a solution of 1 part liquid bleach and 3 parts water. Apply the solution and scrub the mildewed area. Allow the solution to remain on the surface for 10 minutes.
Rinse thoroughly with water and allow the surface to dry before painting. Wear protective eyewear, waterproof gloves, and protective clothing. Quickly wash off any of the mixture that comes in contact with your skin. Do not add detergents or ammonia to the bleach/water solution.
PHYSICAL PROPERTIES
CF16W0051
(may vary by base)
Wind-Driven Rain Test1 :
Method: ASTM D6904-03 Result: Pass
Water Vapor Permeance2 :
Method: ASTM D1653 14 day cure @ 77°F
& 50% RH
Result: 34.4 US perms
Elongation3 :
Method: ASTM D2370, 14 day cure @
77°F & 50% RH
Result: 175%
Tensile Strength3 :
Method: ASTM D2370, 14 day cure @
77°F & 50% RH
Result: 230 p.s.i.
Flexibility:
Method: ASTM D522 , Method A Result: Pass Low Temperature Flexibility :
Method: ASTM D1737 @ 32°F Result: Pass
1 1 coat Loxon Primer at 3.2 mils D.F.T.
2 coat Sherlastic at 4.0-6.0 mils D.F.T.-per coat
2 1 coat Sherlastic at 4.0-6.0 mils D.F.T.
3 1 coat Sherlastic at 4.5 mils D.F.T.
CAUTIONS
For exterior use only.
Protect from freezing.
Not for use on horizontal surfaces (floors, roofs, decks, etc.) where water will collect.
Not for use on overhead horizontal surfaces (under sides of balconies, soffits, etc.)
Not for use below grade. Will not withstand hydrostatic pressure.
Before using, carefully read CAUTIONS on label.
CRYSTALLINE SILICA, ZINC: Use only with adequate ventilation. To avoid overexposure, open windows and doors or use other means to ensure fresh air entry during application and drying. If you experience eye watering, headaches, or dizziness, increase fresh air, or wear respiratory protection (NIOSH approved) or leave the area. Adequate ventilation required when sanding or abrading the dried film. If adequate ventilation cannot be provided wear an approved particulate respirator (NIOSH approved). Follow respirator manufacturer’s directions for respirator use. Avoid contact with eyes and skin. Wash hands after using. Keep container closed when not in use. Do not transfer contents to other containers for storage. FIRST AID: In case of eye contact, flush thoroughly with large amounts of water.
Get medical attention if irritation persists. If swallowed, call Poison Control Center, hospital emergency room, or physician immediately. DELAYED EFFECTS FROM LONG TERM OVEREXPOSURE. Abrading or sanding of the dry film may release crystalline silica which has been shown to cause lung damage and cancer under long term exposure. WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
DO NOT TAKE INTERNALLY. KEEP OUT OF THE
REACH OF CHILDREN.
HOTW 04/07/2020 CF16W0051 13 26
FRC, SP
CLEANUP INFORMATION
Clean spills, spatters, hands and tools immediately after use with soap and warm water. After cleaning, flush spray equipment with a compliant cleanup solvent to prevent rusting of the equipment. Follow manufacturer’s safety recommendations when using solvents.
The information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin-Williams Company. Such information and recommendations set forth herein are subject to change and pertain to the product offered at the time of publication.
Consult your Sherwin-Williams representative or visit www.paintdocs.com to obtain the most current version of the PDS and/or an SDS.