Britespan_55X40_TENT_DWGS__FINAL_210202.pdf
PDF 1 MB Posted
- Attached to
- FS 31 Interim Decommissioning
- Solicitation number
- PW#2026-016
- Issued by
- King County, Spokane City, Washington
About this file
This is a technical drawing package prepared by Britespan Building Systems Inc. for the City of Seattle Finance & Administrative Services, detailing the design and fabrication specifications for a 55-foot by 40-foot Atlas 18.1 fabric tensile tent structure (2,200 square feet) designated for vehicle-commercial use. The project, identified as Sales Order #7534, includes comprehensive structural drawings covering baseplate layouts, purlin and cross-cable configurations, bracing systems, endwall assemblies, and standard connection details. The structure is designed to accommodate specific load conditions including a 25 psf ground snow load, 115 mph wind speeds, and 12 psf roof live loads in accordance with ASCE 7-10, IBC 2015, and Seattle Building Code standards. The fabric envelope utilizes RU88X-6 (FR) 400 material with fire-resistant properties meeting NFPA 701-2015 standards, featuring white exterior fabric on the main cover, endflaps, and endwalls. The drawing package consists of 14 sheets released for construction on July 29, 2020, with five subsequent revisions issued through February 2, 2021, incorporating customer feedback regarding fabric finish, door specifications, purlin additions, and connection details.
The structural system employs hot-dip galvanized steel components per ASTM A123/A123M-17 standards, with welded trusses fabricated to AWS D1.1 and D1.3 specifications by the AWS-certified Britespan Building Systems Inc. The design includes multiple connection details for purlins (2-7/8-inch diameter, 14-gauge), cable bracing systems (5/16-inch diameter cross cables), and structural bolting specifications ranging from SAE Grade 5 to ASTM A325 bolts with detailed torque requirements provided. Foundation design and anchor bolt specifications are delegated to the Professional Structural Engineer (PSE), with minimum edge distances of 4 inches required from anchor centerlines to concrete edges. The project incorporates insulation provisions detailed in Standard Details 4 (SD-4), including R-19, R-38 roof batts and R-13 endwall batts with suspension band support systems. Maintenance requirements mandate 100 percent cable tensioning inspections during years 1-2 annually and 25 percent random inspections during years 3-10 at 24-month intervals, with written reporting to Britespan and the engineer of record required for any inadequate tensioning findings.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COVER PAGE
FB-1
THIS DRAWING IS PROPERTY OF BRITESPAN
BUILDING SYSTEMS INC.. ANY REPRODUCTION IN
WHOLE OR IN PART WITHOUT THE EXPRESSED
WRITTEN CONSENT OF BRITESPAN BUILDING
SYSTEMS INC. IS PROHIBITED. THIS DRAWING IS
NOT TO SCALE UNLESS OTHERWISE NOTED.
DRAWN BY:
CHECKED BY:
DATE:DESCRIPTION:REV #
JLK
PROJECT:
WIDTH-STEEL-FAB-HSS-HSSDROP:
DEALER: CUSTOMER:
ORDER ID:
SHEET NO.:
DRAWING TITLE:
PAGE NO.:
BRITESPAN OF THE PACIFIC NORTHWEST (BPNW)
18449 CASCADE AVENUE SOUTH
TUKWILA, WA. 98188
CITY OF SEATTLE FINANCE & ADMIN SERVICES
10503 INTERLAKE AVENUE NORTH
SEATTLE, WA. 98133
ATLAS 18.1
55'L6 x 40' - 320 GM
5' & 6' oc
SO# 7534
55L6-320-220-14-/
0 ISSUED FOR CONSTRUCTION 29.JUL.2020
1 2 REV. FABRIC FINISH TO 320 & REVISED PER 14.SEP.2020
CUSTOMER COMMENTS - JLK
2 REV. NOTES, DOORS & EW2 PER CUST., PURLINS ADDED - JIKH 02.OCT.2020
3 CR4-7 REVISED PER CUSTOMERS COMMENTS - NLW 14.JAN.2021
4 CR8 REVISED PER CUSTOMERS COMMENTS - NLW 01.FEB.2021
5 CR9 REVISED PER CUSTOMERS COMMENTS - NLW 02.FEB.2021
/14JIKH
TF: 800-407-5846
www.britespanbuildings.com
CR #
This project has been designed and fabricated in accordance with the following:
1. DESCRIPTION
Owner's Name and Address: CITY OF SEATTLE FINANCE & ADMIN SERVICES - KATE SPITZER
10503 INTERLAKE AVENUE NORTH, SEATTLE, WA. 98133
Building Supplier's Name and Address: BRITESPAN OF THE PACIFIC NORTHWEST (BPNW)
18449 CASCADE AVENUE SOUTH, TUKWILA, WA. 98188
Manufacturer's Name and Address: BRITESPAN BUILDING SYSTEMS INC.
688 JOSEPHINE ST. N. R.R.#1, WINGHAM, ON. N0G 2W0
Site Location: 10503 INTERLAKE AVENUE NORTH, SEATTLE, WA. 98133
Legal Address: 10503 INTERLAKE AVENUE NORTH, SEATTLE, WA. 98133
Building Type: ATLAS 18.1
Building Size: 55' x 40' @ 5' & 6' o.c. (2200 sq. ft.)
Applicable Building Code: ASCE 7-10 / IBC 2015 / SBC 2015
Intended Use and Occupancy: VEHICLE - COMMERCIAL
Use Group: CAT IV - S-2
Fabric Type: RU88X-6 (FR) 400
2. DESIGN STANDARDS
The design as per ASCE 7-10 (SECTION 2.4.1 Allowable Stress Design), SEATTLE Existing Building Code with 2015 IBC amendments, Minimum Design
Loads for Building and Other Structures. SANSI / AISC 360-10, Specification for Structural Steel Buildings AISI-Truss, North American Specification for the
Design of Cold-Formed Steel Structural Members NFPA 701, Standard Methods of Fire Tests for Flame Propagation of Textiles and Films, 2015 Edition.
3. MANUFACTURING STANDARDS
Fabrication in accordance with ANSI / AISC 360-10 and AISI-Truss, as applicable. Welding in accordance with AWS D1.1 and D1.3 Structural Welding Code and AISI-Truss, as applicable. BRITESPAN Building Systems Inc. is an AWS approved fabricator as per B5.17 and QC17 standards. Welders have been qualified in accordance with QC7-93.
4. DESIGN CRITERIA
Risk Category: RISK CATEGORY IV
Exposure Category: EXPOSURE B (NON COASTAL)- FULLY EXPOSED
Enclosure Category: PARTIALLY ENCLOSED
A) DEAD LOADS
I) Self-weight of Building Components
II) Collateral (hanging) load, not to exceed 2.0 psf uniform plus 200 lb point loads (7 hanging points as shown in calculation package) as an allowance for mechanical, electrical ceiling, sprinklers, etc, or any combination there of.
B) LIVE LOADS
Live Loads determined in accordance with ASCE 7-10 / IBC 2015 / SEBC 2015
Minimum roof live load. 12.0 psf
C) SNOW LOADS
Snow loads determined in accordance with ASCE 7-10 / IBC 2015 / SEBC 2015
Ground Snow Load, Pg (1/50) 25 psf
Roof Snow Load, Pf 25.2 psf
Exposure Factor, Ce 1.0
Thermal Factor, Ct 1.2
Importance Factor, Is 1.2
Sloped Roof Snow Co-efficient, Cs (0.72 Nominal)
D) WIND LOADS
Wind loads determined in accordance with ASCE 7-10 / IBC 2015 / SEBC 2015
Wind Speed (V ult) 115 mph
Basic Wind Pressure, q 18.86 psf
Exposure Coefficient, Kz 1.00
Topographic Factor, Kzt 1.00
Directionality Factor, Kd 0.85
Wind load reducible by 0.6 in allowable stress load combinations that include wind.
E) LOAD COMBINATIONS
Load combinations determined in accordance with ASCE 7-10 / IBC 2015 / SEBC 2015
BASE REACTION
THE MAXIMUM FORCES AT THE TRUSS SUPPORTS AT ELEVATION 100'-0", DUE TO THE LOADS LISTED ABOVE, ARE AS FOLLOWS:
NOTE: REACTIONS AT COMMON (OR INTERIOR) TRUSSES - END TRUSSES HAVE 1/2 TRIBUTARY WIDTH.
STRUCTURAL BOLT TORQUE VALUES (AS REFERENCE ONLY) RSCS APPROVED METHOD REQUIRED WHERE APPROPRIATE.
TABLE B LISTS THE BOLT CLAMP WITH SUGGESTED ASSEMBLY TORQUE VALUES.
MATERIAL SPECIFICATIONS:
ROLLED STRUCTURAL SECTIONS CONFORM TO ASTM A36 / A36M-14 (42W / 50W).
STRUCTURAL PLATE CONFORMS TO THE FOLLOWING SPECIFICATIONS:
PLATES ASTM A572 GR 42 / 50 & CSA G40.20 300W / 350W
H.S.S. ASTM A500 GRADE C / CSA G40.21 350W
COATINGS OF STRUCTURAL COUPLER & KINGPIN PLATES ARE HOT-DIP GALVANIZED IN ACCORDANCE WITH A123 / A123M-17.
ALL WELDED COMPONENTS (TRUSSES) ARE HOT-DIP GALVANIZED INSIDE AND OUT IN ACCORDANCE ASTM A123 / A123M-17.
PURLINS AND TIE-DOWN PIPE ARE PRE-GALVANIZED.
DIAGONAL BRACE STEEL CABLES EXTRA HIGH STRENGTH PER ASTM A475-03 (2014)
CROSS CABLES - Ø 5/16" TYP U/N.
STRUCTURAL COMPONENTS ARE AS FOLLOWS:
2 3/8" CHORD - 18" O-O USING 1 1/4" DIA. WEBS & 2 7/8" PURLINS.
ALL OTHER SIZE / GAUGES - MIN YIELD = 50ksi.
FABRIC / LINER NOTES
EXTERIOR FABRIC IS AN INTEGRAL PART OF THE STRUCTURAL SYSTEM; REMOVAL OR ALTERATION WITHOUT PRIOR
AUTHORIZATION IS PROHIBITED. ALL TEARS MUST BE PATCHED IMMEDIATELY TO AVOID WARRANTY PROBLEMS.
EXTERIOR FABRIC WILL DEFLECT UNDER LOAD, THEREFORE ALL BUILDING ACCESSORIES (LIGHTING, HVAC, SPRINKLERS, ETC)
MUST BE LOCATED BENEATH THE INNER CORD OF THE TRUSS. ANYTHING ABOVE THIS MUST BE REVIEWED AND APPROVED IN
WRITING BY BRITESPAN BUILDING SYSTEMS, INC. SEVERE DAMAGE TO THE BUILDING AND ACCESSORIES MAY RESULT FROM
FAILURE TO COMPLY WITH THIS REQUIREMENT.
FABRIC SPECIFICATIONS
ALL POLYETHYLENE MEMBRANES WILL POSSESS THE FOLLOWING MINIMUM SPECIFICATIONS:
DWG # DRAWINGS TITLE REL. DATE REL. DATE
FB-1 COVER PAGE 0 29.JUL.2020 5 02.FEB.2021
FB-2 BASEPLATE LAYOUT 0 29.JUL.2020 3 14.JAN.2021
BD-1 BASEPLATE DETAILS 0 29.JUL.2020 2 02.OCT.2020
FB-3 PROJECT LAYOUT 0 29.JUL.2020 2 02.OCT.2020
FB-4 PURLIN & X-CABLE LAYOUT 0 29.JUL.2020 2 02.OCT.2020
FB-5 BRACING LAYOUT - PLAN VIEW 0 29.JUL.2020 2 02.OCT.2020
FB-6 BRACING LAYOUT - ELEVATION 0 29.JUL.2020 2 02.OCT.2020
EW-1 ENDWALL 1 LAYOUT 0 29.JUL.2020 5 02.FEB.2021
EW-2 ENDWALL 2 LAYOUT 0 29.JUL.2020 5 02.FEB.2021
SD-1 STANDARD DETAILS 1 0 29.JUL.2020 2 02.OCT.2020
SD-2 STANDARD DETAILS 2 0 29.JUL.2020 14.JAN.2021
SD-3 STANDARD DETAILS 3 0 29.JUL.2020 2 02.OCT.2020
SD-4 STANDARD DETAILS 4 4 01.FEB.2021
ED-1 ENDWALL DETAILS 0 29.JUL.2020 3 14.JAN.2021
TABLE B - IMPERIAL
SIZE GRADE 5
DIA.
in Threads Per
Inch Tensile ksi
Min Proof Load lbs Clamp Load lbs Torque Dry ft-lbs Torque Lube ft-lbs 3/8 16 120 6600 4950 15 23 7/16 14 120 9050 6780 50 35 1/2 13 120 12100 9050 75 55 5/8 11 120 19200 14400 150 110 3/4 10 120 28400 21300 260 200
SIZE A325
1 1/4 7 105 71700 53800 1120 840 1 1/2 7 135 103000 77300 1775 1330
TABLE A - BOLT TENSION
SIZE GRADE 5
in kips 5/8 18 3/4 28 7/8 39
1.0 51
SIZE A325
1 1/8 56 1 1/4 74 1 1/2 106
FR - RU88X-6 (FR) 400
Physical Properties Description
WEAVE Woven clear HDPE scrim
COATING LDPE, 4 mil (95 g/m /side)
WEIGHT 12 oz/ yd (407 g/m +/-5%
THICKNESS 23 mil (0.59 mm) ASTM D-1777
GRAB TENSILE WARP 370 lb 1664 N ASTM D-5034
WEFT 345 lb 1532 N
STRIP TENSILE (N/5cm) WARP 250 lb/in (2220) ASTM D-5035
WEFT 235 lb/in (2086)
TONGUE TEAR WARP 110 lb 488 N ASTM D-2261
WEFT 100 lb 444 N
TRAPEZOIDAL TEAR WARP 100 lb 444 N ASTM D-4533
WEFT 90 lb 400 N
MULLEN BURST 650 psi (4478 kPa) ASTM D-3786
LOW TEMPERATURE BEND -60°C ASTM D-2136
FR PERFORMANCE NFPA 701-2015, NFPA-701 (1989), ASTM E84-00a
CAN/ULC S109-M87
GENERAL
THIS DRAWING INCLUDES INFORMATION HERE-ON, REMAINS THE PROPERTY OF BRITESPAN BUILDING SYSTEMS, INC.
IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE SALES ORDER AND SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF BRITESPAN BUILDING
SYSTEMS, INC.
THE ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE, GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING
IN CONFORMANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING AND INDUSTRY STANDARDS
PERTAINING TO PROPER ERECTION INCLUDING THE PROPER USE OF TEMPORARY BRACING.
THIS BUILDING IS NOT DESIGNED TO BE LIFTED AS AN ASSEMBLED UNIT. BRITESPAN BUILDING SYSTEMS, INC. IS NOT
RESPONSIBLE FOR LOSSES AND / OR DAMAGE AS A RESULT OF LIFTING THIS BUILDING. IF, HOWEVER, IT HAS BEEN
DETERMINED TO LIFT THIS BUILDING, IT IS THE RESPONSIBILITY OF THE PERSON, FIRM OR COMPANY CONTRACTED TO
LIFT THE BUILDING TO SECURE THE SERVICES OF A QUALIFIED ENGINEER TO ENSURE THE LIFT DOES NOT DAMAGE
THE BUILDING AND TO DETERMINE AND FINALIZE ALL ASPECTS OF THE LIFT INCLUDING ALL PARTS / CONNECTORS TO
BE ADDED TO THE BUILDING TO FACILITATE THE LIFT.
BRITESPAN BUILDING SYSTEMS, INC. IS NOT RESPONSIBLE FOR ERRORS, OMISSION OR DAMAGES INCURRED IN THE
ERECTION OF THE COMPONENTS SHOWN ON THIS DRAWING, NOR FOR THE INSPECTION OF ERECTED COMPONENTS
TO DETERMINE THE SAME. ENGINEER OF RECORD (PSE) IS RESPONSIBLE FOR MEETING THE TERMS OF CONTRACT.
THIS CERTIFICATION AND ENGINEERING SEAL APPLIES ONLY TO PRODUCTS DESIGNED AND FABRICATED BY
BRITESPAN BUILDING SYSTEMS, INC. FOR THE LOADING CONDITIONS DESIGNED ON THESE DRAWINGS. CONCRETE
FOUNDATIONS & MISCELLANEOUS STEEL COMPONENTS ARE DESIGNED BY PSE, SUPPLIED BY BRITESPAN OF THE
PACIFIC NORTHWEST (BPNW). ERECTION SUPERVISION IS THE RESPONSIBILITY OF BRITESPAN OF THE PACIFIC
NORTHWEST (BPNW). ALL DOORS, WINDOWS AND ROLL-UP CURTAINS MUST BE DESIGNED TO SUPPORT THE SITE
WIND LOADING AND ARE RELIED ON TO BE CLOSED IN THE EVENT OF HIGH WINDS.
ANCHOR BOLTS
ANCHOR BOLT DIAMETERS ARE DETERMINED IN ACCORDANCE WITH ASTM F1554 USING MINIMUM GRADE 55 Fy = 55 KSI
(380 MPa). ANCHOR BOLT LENGTHS AND LOAD TRANSFER TO THE FOUNDATION ARE TO BE DETERMINED BY PSE.
REFER TO FOUNDATION DRAWINGS.
ANCHOR BOLT PROJECTIONS AND LENGTHS ARE RESPONSIBILITY OF FOUNDATION ENGINEER (PSE). REFER TO
FOUNDATION DRAWINGS.
FOUNDATION MUST BE LEVEL, SQUARE AND SMOOTH. ANCHOR BOLTS MUST BE ACCURATELY PLACED AS SHOWN ON
THE DRAWINGS.
FINISHED FLOOR ELEVATIONS AND UNDERSIDE OF BASE PLATE IS 100'-0" UNLESS NOTED.
ERECTION
THE ERECTION MUST PROVIDE SAFE WORKING CONDITIONS AND PRACTICES CONFORMING TO ALL SAFETY
REGULATIONS. ALL THE LIFTING DEVICES ARE TO BE SPECIFICALLY DESIGNED TO LIFT THE VARIOUS BUILDING
COMPONENTS. SLINGS AND SPREADER BARS ARE TO BE USED TO PREVENT PERMANENT DEFORMATION OF ALL
STRUCTURAL COMPONENTS.
ERECTION SHOULD START AT A BRACED BAY. ERECT AND TEMPORARILY SUPPORT TRUSSES. USE TEMPORARY
BRACING AS REQUIRED TO ENSURE STABILITY OF THE FRAMES. INSTALL PURLINS AND CROSS BRACING. PLUMB AND
SQUARE TRUSSES IN ACCORDANCE WITH CAN3-S16.1 AND OSHA 29 CFR PART 1926 - SAFETY STANDARD FOR STEEL
ERECTION.
ENSURE ALL PURLINS REMAIN PARALLEL.
STRUCTURAL FRAMING MEMBERS ARE CONSIDERED PLUMB, LEVEL, AND ALIGNED WHEN THE VARIANCE DOES NOT
EXCEED 1:300.
STRUCTURAL BOLTS
BOLTS IN CONNECTIONS NOT SUBJECT TO TENSION LOADS, OR WHERE LOOSENING DUE TO VIBRATION OR LOAD
FLUCTUATIONS ARE NOT DESIGN CONSIDERATIONS NEED ONLY BE SNUG TIGHTENED, WHICH IS DEFINED AS THE
TIGHTNESS THAT EXISTS WHEN ALL PLIES IN A JOINT ARE IN FIRM CONTACT. ALL STRUCTURAL BOLT DIAMETERS LESS
THAN 1" CONFORM TO SAE J429 GR.5., BE PLATED / GALVANIZED OR JS500 COATED FINISH. ALL STRUCTURAL NUT
DIAMETERS LESS THAN 1" CONFORM TO SAE J995 GR.8., BE PLATED / GALVANIZED OR JS500 COATED FINISH.
ALL BOLTS LARGER THAN 1" DIA. CONFORM TO ASTM A325.
ALL OTHER DIA. HEX BOLTS CONFORM TO SAE GR.5 OR EQUIVALENT.
ALL BOLTS SHALL BE PLATED / GALVANIZED OR SUNSEAL COATED.
ALL BOLT REFERENCES REQUIRE BOTH BOLT AND NUT.
BOLTS IN CONNECTIONS NOT SUBJECT TO TENSION LOADS SHALL BE SNUG TIGHTENED PER RCSC 9.1. THE
FOLLOWING TENSION SCHEDULE IS PROVIDED FOR REFERENCE;
NOTE: INSULATION TO BE PROVIDED BY BRITESPAN OF THE PACIFIC NORTHWEST (BPNW)
ROOF PLAN NOTES
UNLESS NOTED, USE Ø5/8" BOLTS FOR PURLIN TO TRUSS, CABLE OR ROD BRACING TO TRUSS AND ANGLES TO TRUSS
FOR ALL CONNECTIONS.
CABLE / ROD AND PURLIN BRACING ARE AN INTEGRAL PART OF THE TRUSS STRUCTURAL SYSTEMS AND SHOULD BE
PROPERLY INSTALLED PRIOR TO ERECTION OF FABRIC ROOF AND ENDWALL PANELS. REMOVAL OR ALTERATION OF
ANY BRACING WITHOUT PRIOR AUTHORIZATION FROM BRITESPAN BUILDING SYSTEMS, INC. IS PROHIBITED.
ELEVATION NOTES
HOLES REQUIRED IN HSS COLUMNS, HEADERS OR PURLINS FOR FRAMED OPENINGS - FIELD DRILLED. DOOR OR
WINDOW POST CONNECTIONS TO BE BY ERECTOR.
WALK DOOR, WINDOW AND FRAMED OPENING POSTS TO BE FIELD ANCHORED TO CONCRETE WITH Ø1/2" "HILTI
KWIK-BOLTS" OR SIMILAR
MATERIAL STORAGE
GALVANIZED, ALUMINIZED, AND COLORED MATERIALS ARE SUBJECT TO CORROSION AND DISCOLORATION IF THEY ARE
IMPROPERLY STORED. SHORT TERM JOB SITE STORAGE OF STEEL COMPONENTS MAY BE TOLERATED, PROVIDED CARE
IS TAKEN TO KEEP THE MATERIALS DRY AT ALL TIMES. WHEN TRUSSES ARE TO BE STORED OUTDOORS, THEY SHOULD
BE PLACED AT AN ANGLE SUFFICIENT TO PROMOTE GOOD DRAINAGE. IN ADDITION, SEVERAL INCHES OF CLEARANCE
MUST BE PROVIDED BETWEEN THE LOWER END AND THE GROUND TO ALLOW VENTILATION.
NOTE: BRITESPAN BUILDING SYSTEMS, INC. WILL NOT BE HELD RESPONSIBLE FOR MATERIALS WHICH ARE IMPROPERLY
PROTECTED AFTER DELIVERY.
BRITESPAN BUILDING SYSTEMS, INC. IS AN AWS CERTIFIED DIVISION 2.1 MANUFACTURER OF TRUSSES. ALL WELDS ARE
COMPLETED IN SHOP AS PER AWS STANDARD AWS D1.3. AS PART OF OUR AWS CERTIFICATION AN INDEPENDENT THIRD
PARTY TESTS OUR WELDERS AND PROCEDURES AND AUDITS OUR FACILITIES. THIS CERTIFICATION MEETS WITH AWS
D1.1 AND D1.3 CRITERIA.
FOUNDATION DESIGN IS BY PSE.
MINIMUM EDGE DISTANCE OF ANCHOR BOLT CENTRELINE TO EDGE OF CONCRETE FOUNDATION SHALL BE 4 INCHES.
ANCHOR DESIGN IS BY FOUNDATION ENGINEER (PSE).
FOUNDATION DESIGNER (PSE) SHALL DETERMINE ANCHOR BOLT SIZE AND TYPE FOR BRITESPAN LOADS. PROPER
MINIMUM EDGE DISTANCE FROM CENTER OF ANCHORS TO EDGE OF CONCRETE SIDEWALLS AND ENDWALLS SHALL BE
PROVIDED FOR THE ANCHOR TYPE. FOR FOUNDATION DESIGN & RESPONSIBILITY - PLEASE SEE FOUNDATION
DRAWINGS (DESIGNED & SUPPLIED BY PSE).
*** MAINTENANCE REQUIREMENTS FOR THE STRUCTURE ***
Years 1 - 2 every 12 months - 100% of all cable tensioning inspected and reported to in writing to BRITESPAN and Engineer of structure.
Years 3 - 10 every 24 months - 25% of all cable tensioning (randomly chosen) - where tensioning found not adequate, check all other similar cable tensioning, report in writing to BRITESPAN and Engineer of structure.
*** NOTE ***
TEMPORARY BRACING / SUPPORTS REQUIRED DURING ERECTION OF BUILDING. BRACING MUST
REMAIN IN PLACE UNTIL STRUCTURE AND ALL PERMANENT BRACING IS COMPLETELY
INSTALLED.
TEMPORARY BRACING DESIGN AND SUPPLY IS NOT THE RESPONSIBILITY OF BRITESPAN
BUILDING SYSTEMS INC.
TEMPORARY BRACING - DESIGN & SUPPLY IS THE SOLE RESPONSIBILITY OF BRITESPAN OF THE
PACIFIC NORTHWEST AND THEIR INSTALL TEAM.
END WALL UNFACTORED REACTIONS - SO-7534
PART #
WIND
PRESSURE
(Ksf)
VERT.
REACTION
(Kip)
LONGIT.
REACTION
(Kip)
END 1
EC-1 0.02 0.54 1.67
EC-2 0.02 0.96 2.62
EC-3 0.02 0.98 2.68
END 2
EC-1 0.02 0.70 2.89
EC-2 0.02 0.98 3.79
40'-0" C-C OF TRUSSES
A
B
C
C
O
F
A
N C
H O
R
B
O L
T S
40'-3" O-O OF BASEPLATES
O
B
A S
E P
L A
T E
S
83 4 5 76
BD-1
C
BD-1
B
BD-1
A
5'-0" o/c
BD-1
D
68'-1 7/8"68'-1 7/8"
6'-0" o/c
TYP. U/N
5'-0" o/c
4'-0"
1'-8"
1'-8"
4'-0"
BD-1
E
3'-4" CLEAR
ANCHORED BY
BPNW
3'-4" CLEAR
ANCHORED BY
BPNW
A N
C H
O R
E D
B
Y
B
P N
W A
N C
H O
R E
D
B
Y
B
P N
W A
N C
H O
R E
D
B
Y
B
P N
W
BASEPLATE LAYOUT
FB-2
THIS DRAWING IS PROPERTY OF BRITESPAN
BUILDING SYSTEMS INC.. ANY REPRODUCTION IN
WHOLE OR IN PART WITHOUT THE EXPRESSED
WRITTEN CONSENT OF BRITESPAN BUILDING
SYSTEMS INC. IS PROHIBITED. THIS DRAWING IS
NOT TO SCALE UNLESS OTHERWISE NOTED.
DRAWN BY:
CHECKED BY:
DATE:DESCRIPTION:REV #
JLK
PROJECT:
WIDTH-STEEL-FAB-HSS-HSSDROP:
DEALER: CUSTOMER:
ORDER ID:
SHEET NO.:
DRAWING TITLE:
PAGE NO.:
BRITESPAN OF THE PACIFIC NORTHWEST (BPNW)
18449 CASCADE AVENUE SOUTH
TUKWILA, WA. 98188
CITY OF SEATTLE FINANCE & ADMIN SERVICES
10503 INTERLAKE AVENUE NORTH
SEATTLE, WA. 98133
ATLAS 18.1
55'L6 x 40' - 320 GM
5' & 6' oc
SO# 7534
55L6-320-220-14-/
0 ISSUED FOR CONSTRUCTION 29.JUL.2020
1 2 REV. FABRIC FINISH TO 320 & REVISED PER 14.SEP.2020
CUSTOMER COMMENTS - JLK
2 REV. NOTES, DOORS & EW2 PER CUST., PURLINS ADDED - JIKH 02.OCT.2020
3 CR4-7 REVISED PER CUSTOMERS COMMENTS - NLW 14.JAN.2021
4 CR8 REVISED PER CUSTOMERS COMMENTS - NLW 01.FEB.2021
5 CR9 REVISED PER CUSTOMERS COMMENTS - NLW 02.FEB.2021
/14JIKH
TF: 800-407-5846
www.britespanbuildings.com
CR #
BD-1
A
ATLAS 18 - LEFT
BASEPLATE DETAIL
BD-1
C
ATLAS 18 - RIGHT
BASEPLATE DETAIL
BD-1
B
ATLAS 18 - COMMON
BASEPLATE DETAIL
GRID
8"
8"
4" 4"
4"
4"
8"
8"
4"
6 1/2"
4"
1 1/2"
2) 13/16" HOLES ANCHOR
BOLTS, DESIGNED BY PSE
& SUPPLIED BY BPNW
1" 6"1"
1" 4" 3"
GRID
GRID
GRIDGRID GRID
Ø
Ø
2) 13/16" HOLES ANCHOR
BOLTS, DESIGNED BY PSE
& SUPPLIED BY BPNW
2) 13/16" HOLES ANCHOR
BOLTS, DESIGNED BY PSE
& SUPPLIED BY BPNW
8"
8"
4"
6 1/2"
4"
1 1/2"
1" 4"3"
Ø
O/S
I/S
I/SO/S
O/S
I/S
O/S
I/S
I/S O/S
TRUSS ANCHOR NOTES:
1) BASE PLATES DESIGNED FOR Ø 5/8" OR
Ø 3/4" ANCHORS.
2) ANCHOR TYPE, EMBEDMENT AND
PROJECTION AS DETERMINED BY
FOUNDATION ENGINEER - PSE.
3) ALL ANCHORS TO BE SUPPLIED &
INSTALLED BY BPNW.
3"
3"
5"
GRID
I/S O/S
E
BD-1
BASEPLATE DETAIL
6X4 HEADER / BASE
ANCHOR BOLTS
DESIGNED BY PSE &
SUPPLIED BY BPNW
C
L
ANCHOR-BOLT HOLES: Ø 11/16"
PLATE THICKNESS: 1/4"
PART NUMBER: 2407
8"
4"
5"
3"
3"
7"
GRID
I/S O/S
D
BD-1
BASEPLATE DETAIL
8X4 HEADER / BASE
ANCHOR BOLTS
DESIGNED BY PSE &
SUPPLIED BY BPNW
C
L
ANCHOR-BOLT HOLES: Ø 11/16"
PLATE THICKNESS: 1/4"
PART NUMBER: 2372
8"
4"
7"
END WALL ANCHOR NOTES:
1) BASE PLATES DESIGNED FOR TWO
Ø 5/8" ANCHORS.
2) ANCHOR TYPE, EMBEDMENT AND
PROJECTION AS DETERMINED BY
FOUNDATION ENGINEER - PSE.
3) ALL ANCHORS TO BE SUPPLIED &
INSTALLED BY BPNW.
BASEPLATE DETAILS
BD-1
THIS DRAWING IS PROPERTY OF BRITESPAN
BUILDING SYSTEMS INC.. ANY REPRODUCTION IN
WHOLE OR IN PART WITHOUT THE EXPRESSED
WRITTEN CONSENT OF BRITESPAN BUILDING
SYSTEMS INC. IS PROHIBITED. THIS DRAWING IS
NOT TO SCALE UNLESS OTHERWISE NOTED.
DRAWN BY:
CHECKED BY:
DATE:DESCRIPTION:REV #
JLK
PROJECT:
WIDTH-STEEL-FAB-HSS-HSSDROP:
DEALER: CUSTOMER:
ORDER ID:
SHEET NO.:
DRAWING TITLE:
PAGE NO.:
BRITESPAN OF THE PACIFIC NORTHWEST (BPNW)
18449 CASCADE AVENUE SOUTH
TUKWILA, WA. 98188
CITY OF SEATTLE FINANCE & ADMIN SERVICES
10503 INTERLAKE AVENUE NORTH
SEATTLE, WA. 98133
ATLAS 18.1
55'L6 x 40' - 320 GM
5' & 6' oc
SO# 7534
55L6-320-220-14-/
0 ISSUED FOR CONSTRUCTION 29.JUL.2020
1 2 REV. FABRIC FINISH TO 320 & REVISED PER 14.SEP.2020
CUSTOMER COMMENTS - JLK
2 REV. NOTES, DOORS & EW2 PER CUST., PURLINS ADDED - JIKH 02.OCT.2020
3 CR4-7 REVISED PER CUSTOMERS COMMENTS - NLW 14.JAN.2021
4 CR8 REVISED PER CUSTOMERS COMMENTS - NLW 01.FEB.2021
5 CR9 REVISED PER CUSTOMERS COMMENTS - NLW 02.FEB.2021
/14
JIKH
TF: 800-407-5846
www.britespanbuildings.com
CR #
FOUNDATION DESIGNED BY
PSE & SUPPLIED BY BPNW
S
E
P
L
A
T
E
S
G
R
I
L
E
V
A
T
I
N w x h
R
A
T
E
D
D
O
O
R h
R
A
T
E
D
D
O
O
R h
R
A
T
E
D
D
O
O
R o c
S
E
P
L
A
T
E
S
S
I
E
V
A
T
I
O
N o c
T
Y
P
U
N o c
S
E
P
L
A
T
E
S
G
R
I
E
V
A
T
I o c
S
E
P
L
A
T
E
S
S
I
E
V
A
T
I
O
N o c
T
Y
P
U
N o c
MAIN COVER: WHITE FR
ENDFLAPS: WHITE FR
ENDWALLS: WHITE FR
THIS DRAWING IS PROPERTY OF BRITESPAN
BUILDING SYSTEMS INC.. ANY REPRODUCTION IN
WHOLE OR IN PART WITHOUT THE EXPRESSED
WRITTEN CONSENT OF BRITESPAN BUILDING
SYSTEMS INC. IS PROHIBITED. THIS DRAWING IS
NOT TO SCALE UNLESS OTHERWISE NOTED.
DRAWN BY:
CHECKED BY:
DATE:DESCRIPTION:REV #
JLK
PROJECT:
WIDTH-STEEL-FAB-HSS-HSSDROP:
DEALER: CUSTOMER:
ORDER ID:
SHEET NO.:
DRAWING TITLE:
PAGE NO.:
BRITESPAN OF THE PACIFIC NORTHWEST (BPNW)
18449 CASCADE AVENUE SOUTH
TUKWILA, WA. 98188
CITY OF SEATTLE FINANCE & ADMIN SERVICES
10503 INTERLAKE AVENUE NORTH
SEATTLE, WA. 98133
ATLAS 18.1
55'L6 x 40' - 320 GM
5' & 6' oc
SO# 7534
55L6-320-220-14-/
0 ISSUED FOR CONSTRUCTION 29.JUL.2020
1 2 REV. FABRIC FINISH TO 320 & REVISED PER 14.SEP.2020
CUSTOMER COMMENTS - JLK
2 REV. NOTES, DOORS & EW2 PER CUST., PURLINS ADDED - JIKH 02.OCT.2020
3 CR4-7 REVISED PER CUSTOMERS COMMENTS - NLW 14.JAN.2021
4 CR8 REVISED PER CUSTOMERS COMMENTS - NLW 01.FEB.2021
5 CR9 REVISED PER CUSTOMERS COMMENTS - NLW 02.FEB.2021
/14
JIKH
TF: 800-407-5846
www.britespanbuildings.com
CR #
PROJECT LAYOUT
FB-3
FOUNDATION DESIGNED BY
PSE & SUPPLIED BY BPNW
NOTE:
BUILDING IS DESIGNED AS FULLY
EXPOSED (Ce=1.0) AND PARTIALLY
ENCLOSED
SD-2
FB-4
A-A
54'-4" C-C OF ANCHOR BOLTS
55' O-O OF BASEPLATES
2 5
P
SD-2
M
P
SD-2
N
P
41 1 4
C1
C1
C1
P
C1
P
C2
P
P
C1
C1
C1
P
C1
P
C2
3 7
PURLIN LAYOUT
FOR CABLE
BRACED BAYS
BRACED BAYS
GRIDLINES 1-8
P
P
P
P
P
P
P
P
ATLAS 18.1
55' L6
11' BAY 12' BAY
ITEM # LENGTH ITEM # LENGTH
C1 CABLE 861182-9 182" 861191-9 191"
C2 CABLE 861149-9 149" 861160-9 160"
CABLE LEGEND
ITEM DESCRIPTION
CROSS CABLE 5/16"
BRACING LEGEND
ITEM DESCRIPTION
X = CROSS CABLE 5/16"
P = TYPICAL PURLIN - 2-7/8" DIA. X 14 GA.
PURLIN & X-CABLE LAYOUT
FB-4
THIS DRAWING IS PROPERTY OF BRITESPAN
BUILDING SYSTEMS INC.. ANY REPRODUCTION IN
WHOLE OR IN PART WITHOUT THE EXPRESSED
WRITTEN CONSENT OF BRITESPAN BUILDING
SYSTEMS INC. IS PROHIBITED. THIS DRAWING IS
NOT TO SCALE UNLESS OTHERWISE NOTED.
DRAWN BY:
CHECKED BY:
DATE:DESCRIPTION:REV #
JLK
PROJECT:
WIDTH-STEEL-FAB-HSS-HSSDROP:
DEALER: CUSTOMER:
ORDER ID:
SHEET NO.:
DRAWING TITLE:
PAGE NO.:
BRITESPAN OF THE PACIFIC NORTHWEST (BPNW)
18449 CASCADE AVENUE SOUTH
TUKWILA, WA. 98188
CITY OF SEATTLE FINANCE & ADMIN SERVICES
10503 INTERLAKE AVENUE NORTH
SEATTLE, WA. 98133
ATLAS 18.1
55'L6 x 40' - 320 GM
5' & 6' oc
SO# 7534
55L6-320-220-14-/
0 ISSUED FOR CONSTRUCTION 29.JUL.2020
1 2 REV. FABRIC FINISH TO 320 & REVISED PER 14.SEP.2020
CUSTOMER COMMENTS - JLK
2 REV. NOTES, DOORS & EW2 PER CUST., PURLINS ADDED - JIKH 02.OCT.2020
3 CR4-7 REVISED PER CUSTOMERS COMMENTS - NLW 14.JAN.2021
4 CR8 REVISED PER CUSTOMERS COMMENTS - NLW 01.FEB.2021
5 CR9 REVISED PER CUSTOMERS COMMENTS - NLW 02.FEB.2021
/14JIKH
TF: 800-407-5846
www.britespanbuildings.com
CR #
ATLAS 18.1 - 55'L6 WIDE
TRUSS COMPONENTS FOR ATLAS 18.1 - 55' L6
LOCATION ITEM # PART # QTY. DESCRIPTION
INTERIOR
1 6285 3 TRUSS - A18.1 - 50' - COMMON
2 6262 2 TRUSS - A18.1 - 50' STRONG HALF - COMMON
3 7103 2 LEG - A18.1 - 55L6 COMMON
END
4 6286 3 TRUSS - A18.1 - 50' - END
5 6263 2 TRUSS - A18.1 - 50' STRONG HALF - END
6 7104 1 LEG - A18.1 - 55L6 - LEFT END
7 7105 1 LEG - A18.1 - 55L6 - RIGHT END
ZERO-TO-ZERO OF BASE PLATES = 96'-1 3/8"
ASSEMBLED TRUSS WEIGHT w/ BASEPLATES ~ 830 lbs (each)
FABRIC PANEL
OUTER CHORD
(ALL GRIDS)
DETAIL A-A
THERMA TAPE - APPLY
GROUND TO GROUND,
APPLY ON TOP OF
COUPLER PROTECTORS
B
C
C
A
N C
H O
R
B
O L
T S
84 5 76
SD-1
L
SD-1
K
SD-1
G
SD-1
I
40'-0" C-C OF TRUSSES
5'-0" o/c
6'-0" o/c
TYP. U/N
5'-0" o/c
CABLE LEGEND
ITEM DESCRIPTION
CROSS CABLE 5/16"
PURLIN LEGEND
ITEM DESCRIPTION
TYPICAL PURLIN 2-7/8" DIA. X 14 GA.
PLAN VIEW
FOR PURLIN DETAILS SEE: SD-1
FOR CABLE DETAILS SEE: SD-2
BRACING LAYOUT - PLAN VIEW
FB-5
THIS DRAWING IS PROPERTY OF BRITESPAN
BUILDING SYSTEMS INC.. ANY REPRODUCTION IN
WHOLE OR IN PART WITHOUT THE EXPRESSED
WRITTEN CONSENT OF BRITESPAN BUILDING
SYSTEMS INC. IS PROHIBITED. THIS DRAWING IS
NOT TO SCALE UNLESS OTHERWISE NOTED.
DRAWN BY:
CHECKED BY:
DATE:DESCRIPTION:REV #
JLK
PROJECT:
WIDTH-STEEL-FAB-HSS-HSSDROP:
DEALER: CUSTOMER:
ORDER ID:
SHEET NO.:
DRAWING TITLE:
PAGE NO.:
BRITESPAN OF THE PACIFIC NORTHWEST (BPNW)
18449 CASCADE AVENUE SOUTH
TUKWILA, WA. 98188
CITY OF SEATTLE FINANCE & ADMIN SERVICES
10503 INTERLAKE AVENUE NORTH
SEATTLE, WA. 98133
ATLAS 18.1
55'L6 x 40' - 320 GM
5' & 6' oc
SO# 7534
55L6-320-220-14-/
0 ISSUED FOR CONSTRUCTION 29.JUL.2020
1 2 REV. FABRIC FINISH TO 320 & REVISED PER 14.SEP.2020
CUSTOMER COMMENTS - JLK
2 REV. NOTES, DOORS & EW2 PER CUST., PURLINS ADDED - JIKH 02.OCT.2020
3 CR4-7 REVISED PER CUSTOMERS COMMENTS - NLW 14.JAN.2021
4 CR8 REVISED PER CUSTOMERS COMMENTS - NLW 01.FEB.2021
5 CR9 REVISED PER CUSTOMERS COMMENTS - NLW 02.FEB.2021
/14JIKH
TF: 800-407-5846
www.britespanbuildings.com
CR #
21 83 4 5 76
BD-1
B
SD-1
F
BD-1
A/C
SD-1
H
SD-1
L
SD-1
I
SD-1
J
40'-0" C-C OF TRUSSES
5'-0" o/c
6'-0" o/c
TYP. U/N
5'-0" o/c
SD-1
G
CABLE LEGEND
ITEM DESCRIPTION
CROSS CABLE 5/16"
PURLIN LEGEND
ITEM DESCRIPTION
TYPICAL PURLIN 2-7/8" DIA. X 14 GA.
BRACING LAYOUT - ELEVATION
FB-6
THIS DRAWING IS PROPERTY OF BRITESPAN
BUILDING SYSTEMS INC.. ANY REPRODUCTION IN
WHOLE OR IN PART WITHOUT THE EXPRESSED
WRITTEN CONSENT OF BRITESPAN BUILDING
SYSTEMS INC. IS PROHIBITED. THIS DRAWING IS
NOT TO SCALE UNLESS OTHERWISE NOTED.
DRAWN BY:
CHECKED BY:
DATE:DESCRIPTION:REV #
JLK
PROJECT:
WIDTH-STEEL-FAB-HSS-HSSDROP:
DEALER: CUSTOMER:
ORDER ID:
SHEET NO.:
DRAWING TITLE:
PAGE NO.:
BRITESPAN OF THE PACIFIC NORTHWEST (BPNW)
18449 CASCADE AVENUE SOUTH
TUKWILA, WA. 98188
CITY OF SEATTLE FINANCE & ADMIN SERVICES
10503 INTERLAKE AVENUE NORTH
SEATTLE, WA. 98133
ATLAS 18.1
55'L6 x 40' - 320 GM
5' & 6' oc
SO# 7534
55L6-320-220-14-/
0 ISSUED FOR CONSTRUCTION 29.JUL.2020
1 2 REV. FABRIC FINISH TO 320 & REVISED PER 14.SEP.2020
CUSTOMER COMMENTS - JLK
2 REV. NOTES, DOORS & EW2 PER CUST., PURLINS ADDED - JIKH 02.OCT.2020
3 CR4-7 REVISED PER CUSTOMERS COMMENTS - NLW 14.JAN.2021
4 CR8 REVISED PER CUSTOMERS COMMENTS - NLW 01.FEB.2021
5 CR9 REVISED PER CUSTOMERS COMMENTS - NLW 02.FEB.2021
/14JIKH
TF: 800-407-5846
www.britespanbuildings.com
CR #
ELEVATION
TRUSS BASEPLATES
ELEV. 100'-0"
FOUNDATION BASE
ELEV. PER GRADE
FOR PURLIN DETAILS SEE: SD-1
FOR CABLE DETAILS SEE: SD-2
FOUNDATION DESIGNED BY
PSE & SUPPLIED BY BPNW
TRUSS BASEPLATES
ELEV. 100'-0"
FOUNDATION BASE
ELEV. 99'-6"
14'-4"
ZERO
FOUNDATION
DESIGNED BY PSE &
SUPPLIED BY BPNW
4'-0"
HD-1
E C
14'-4"
14'-0"
14'-0"
13'-11" [167]13'-11" [167]
14'-0"
14'-4"
1'-8" 1'-8"
E C
E C
E C
HD-1HD-1
4'-0"
E C
E C
L
E G
13'-11" [167]
HZ-1
14'w x 14'h
RATED DOOR
14'w x 14'h
RATED DOOR
14'w x 14'h
RATED DOOR
PART # QTY.
COMPONENTS (in)
EC-1 2 1521- HSS- VERT- 4" X 8" X 3/16"- 5" CENTRES- 199"
166 6 BRKT- HSS TOP SADDLE W/ TAB - 2 3/8" CHORD
562 6 BRKT- TOP PLATE ASSY. 4x8/10- 2 3/8"/2 7/8"/3 1/2" CRD
2372 24 HEADER/ BASE ANGLE- 4" X 8" HSS - 5" CENTRES
EC-2 2 1521- HSS- VERT- 4" X 8" X 3/16"- 5" CENTRES- 354"
EC-3 2 1521- HSS- VERT- 4" X 8" X 3/16"- 5" CENTRES- 360"
HD-1 3 2373- HSS- HEADER- 4" X 8" X 3/16"- 5" CENTRES- 201"
HZ-1 1
1528-39 (2 1/2 - 14GA) + 1530-146 ( 2 7/8"-14GA) PRE-GALV
195 2 BRKT - ESS HORIZ. ANGLE
4784 6 DOOR ANGLE - TOP OF WALL TO HSS
54'-4" C-C OF ANCHOR BOLTS
55' O-O OF BASEPLATES
GRID A GRID B
H H H HHH U/S BASE
EL: 100'-0"
T.O. FINISHED FLOOR
EL: 99'-6"
36" X 36"
FRAMED VENT
BY BPNW
ANCHORED
BY BPNW
2) 1-1/2" DIA.
PENETRATIONS FOR
COMMUNICATIONS
CONDUITS BY BPNW
ANCHORED
BY BPNW
ANCHORED
BY BPNW
V
X
CC
ENDWALL 1 LAYOUT
EW-1
THIS DRAWING IS PROPERTY OF BRITESPAN
BUILDING SYSTEMS INC.. ANY REPRODUCTION IN
WHOLE OR IN PART WITHOUT THE EXPRESSED
WRITTEN CONSENT OF BRITESPAN BUILDING
SYSTEMS INC. IS PROHIBITED. THIS DRAWING IS
NOT TO SCALE UNLESS OTHERWISE NOTED.
DRAWN BY:
CHECKED BY:
DATE:DESCRIPTION:REV #
JLK
PROJECT:
WIDTH-STEEL-FAB-HSS-HSSDROP:
DEALER: CUSTOMER:
ORDER ID:
SHEET NO.:
DRAWING TITLE:
PAGE NO.:
BRITESPAN OF THE PACIFIC NORTHWEST (BPNW)
18449 CASCADE AVENUE SOUTH
TUKWILA, WA. 98188
CITY OF SEATTLE FINANCE & ADMIN SERVICES
10503 INTERLAKE AVENUE NORTH
SEATTLE, WA. 98133
ATLAS 18.1
55'L6 x 40' - 320 GM
5' & 6' oc
SO# 7534
55L6-320-220-14-/
0 ISSUED FOR CONSTRUCTION 29.JUL.2020
1 2 REV. FABRIC FINISH TO 320 & REVISED PER 14.SEP.2020
CUSTOMER COMMENTS - JLK
2 REV. NOTES, DOORS & EW2 PER CUST., PURLINS ADDED - JIKH 02.OCT.2020
3 CR4-7 REVISED PER CUSTOMERS COMMENTS - NLW 14.JAN.2021
4 CR8 REVISED PER CUSTOMERS COMMENTS - NLW 01.FEB.2021
5 CR9 REVISED PER CUSTOMERS COMMENTS - NLW 02.FEB.2021
/14JIKH
TF: 800-407-5846
www.britespanbuildings.com
CR #
GRIDLINE 1 - END 1
AA 195
X 2372
V 166, 562
NOTES:
1. "H" DENOTES BLOCK WINCH & STRAP FOR FASTENING TUBE
2. EC VERTICAL LOCATION DIMENSIONS ARE TO THE CENTRELINE OF MEMBERS
3. FIELD DRILL HSS AS REQUIRED
4. FINAL FABRIC TERMINATION DESIGNED & SUPPLIED BY BPNW FOR ALL APRONS
5. STL STUDS FOR INSULATIONS ARE ON THE STEM WALLS. SOME UNISTRUTS FOR
EQUIPMENT SUPPORT ARE ALSO ANCHORED TO THE STEM WALL. REFER TO
STRUCTURAL DWG.
AA
CC 4784
5 6
5'-0" 6'-8"
C
HZ-1
E C
E C
E C
8'-4" 8'-4" 11'-8"11'-8" 14'-4"
10'-0 1/4" [120
PART # QTY.
COMPONENTS (in)
EC-1 2 2408- HSS- VERTICAL- 4" X 6" X 3/16"- 3" CENTRES- 306"
161 2 BRKT- 6" DEEP HSS TOP SADDLE- 2-3/8" CHORD
2407 4 HEADER/ BASE ANGLE- 4" X 6" HSS - 3" CENTRES
EC-2 2 1521- HSS- VERT- 4" X 8" X 3/16"- 5" CENTRES- 354"
166 2 BRKT- HSS TOP SADDLE W/ TAB - 2 3/8" CHORD
562 2 BRKT- TOP PLATE ASSY. 4x8/10- 2 3/8"/2 7/8"/3 1/2" CRD
2372 4 HEADER/ BASE ANGLE- 4" X 8" HSS - 5" CENTRES
EC-3 2 1518-HSS- VERTICAL- 4" X 4" X 1/8"- 2" CENTRES - 120.25"
7114 2 SQUARE CHORD BRACKET TO 4" X 4" HSS
2805 4 HEADER/ BASE ANGLE- 4" X 4" HSS - 2" CENTRES
HZ-1 1
1528-39 (2 1/2 - 14GA) + 1530-146 ( 2 7/8" 14GA) PRE-GALV
195 2 BRKT - ESS HORIZ. ANGLE
HD-1 4 1523- HSS- HEADER- 4" X 4" X 1/8"- 83"
189 8 HEADER ANGLE- 4" X 4" HSS - 2" CENTRES
U/S BASE
EL: 100'-0"
BASE WALL
EL: PER GRADE
ZERO
FOUNDATION
DESIGNED BY PSE &
SUPPLIED BY BPNW
L
E G
54'-4" C-C OF ANCHOR BOLTS
55' O-O OF BASEPLATES
GRID B GRID A
H H HH H H H H HHHHH
T.O. FINISHED FLOOR
EL: ~98'-8" (2% SLOPE)
H
3'-4"
H D
H D
EC-3
NOTE:
DUE TO THE COMPLEX NATURE OF VARYING
MANUFACTURED COMPONENTS, UNISTRUT &
MECHANICAL ATTACHMENTS TO BE PROVIDED &
INSTALLED BY TRADE SPECIFIC CONTRACTORS.
3'-4"
H D
H D
EC-3
ANCHORED
BY BPNW
ANCHORED
BY BPNW
ATTACHMENT
POINT
TYP.
ATTACHMENT POINT
TYP.
SEE DETAIL C-C
EW-2
C-C
EW-2
C-C
EW-2
C-C
H
3" OPENING FOR 2"
FRAMED VENT BY
BPNW
18" EXHAUST
DUCT BY BPNW
36" X 36"
FRAMED VENT
BY BPNW
M
X
M
X
PANEL
POINT
TYP.
ENDWALL 2 LAYOUT
EW-2
THIS DRAWING IS PROPERTY OF BRITESPAN
BUILDING SYSTEMS INC.. ANY REPRODUCTION IN
WHOLE OR IN PART WITHOUT THE EXPRESSED
WRITTEN CONSENT OF BRITESPAN BUILDING
SYSTEMS INC. IS PROHIBITED. THIS DRAWING IS
NOT TO SCALE UNLESS OTHERWISE NOTED.
DRAWN BY:
CHECKED BY:
DATE:DESCRIPTION:REV #
JLK
PROJECT:
WIDTH-STEEL-FAB-HSS-HSSDROP:
DEALER: CUSTOMER:
ORDER ID:
SHEET NO.:
DRAWING TITLE:
PAGE NO.:
BRITESPAN OF THE PACIFIC NORTHWEST (BPNW)
18449 CASCADE AVENUE SOUTH
TUKWILA, WA. 98188
CITY OF SEATTLE FINANCE & ADMIN SERVICES
10503 INTERLAKE AVENUE NORTH
SEATTLE, WA. 98133
ATLAS 18.1
55'L6 x 40' - 320 GM
5' & 6' oc
SO# 7534
55L6-320-220-14-/
0 ISSUED FOR CONSTRUCTION 29.JUL.2020
1 2 REV. FABRIC FINISH TO 320 & REVISED PER 14.SEP.2020
CUSTOMER COMMENTS - JLK
2 REV. NOTES, DOORS & EW2 PER CUST., PURLINS ADDED - JIKH 02.OCT.2020
3 CR4-7 REVISED PER CUSTOMERS COMMENTS - NLW 14.JAN.2021
4 CR8 REVISED PER CUSTOMERS COMMENTS - NLW 01.FEB.2021
5 CR9 REVISED PER CUSTOMERS COMMENTS - NLW 02.FEB.2021
/14
JIKH
TF: 800-407-5846
www.britespanbuildings.com
CR #
GRIDLINE 8 - END 2
V
W
Y
D
V 166, 562
W 161
AA 195
BB 7114
Y 2805
NOTES:
1. "H" DENOTES BLOCK WINCH & STRAP FOR FASTENING TUBE
2. EC VERTICAL LOCATION DIMENSIONS ARE TO THE CENTRELINE OF MEMBERS
3. FIELD DRILL HSS AS REQUIRED
4. FINAL FABRIC TERMINATION DESIGNED & SUPPLIED BY BPNW FOR ALL APRONS
5. STL STUDS FOR INSULATIONS ARE ON THE STEM WALLS. SOME UNISTRUTS FOR EQUIPMENT SUPPORT
ARE ALSO ANCHORED TO THE STEM WALL. REFER TO STRUCTURAL DWG.
BB Z
E
AA
Z 189
Da 2372 (4X8)
E 2407 (4X6)
DETAIL C-C
ALL CONNECTIONS TO TRUSS MUST BE
INSTALLED WITHIN 2" OF A PANEL POINT.
NO CONNECTIONS TO PURLINS ALLOWED.
SD-1
K
COMMON PURLIN
CONNECTION DETAIL
2) 5/8"Ø x 2 1/2"
HEX BOLTS TYP.
2) 5/8"Ø x 2 1/2"
HEX BOLTS TYP.
O U
T S
I D
E
D
G
SD-1
F
420 COMMON LEG
CONNECTION DETAIL
COMMON LEG TRUSS
COMMON
BASEPLATE PLATE
ANCHOR BOLTS &
FOUNDATION
DESIGNED BY PSE &
SUPPLIED BY BPNW
(TYP.)
2) 13/16"Ø HOLES FOR
ANCHOR BOLTS DESIGNED BY PSE
& SUPPLIED BY BPNW
CABLE TABS
TOP VIEW
SD-1
H
420 END LEG
CONNECTION DETAIL
END LEG TRUSS
END
BASEPLATE PLATE
ANCHOR BOLTS &
FOUNDATION
DESIGNED BY PSE &
SUPPLIED BY BPNW
(TYP.)
2) 13/16"Ø HOLES FOR
ANCHOR BOLTS DESIGNED BY PSE
& SUPPLIED BY BPNW
CABLE TAB
TOP VIEW
COMMON
INTERIOR TRUSS
2) 5/8"Ø x 2 1/2"
HEX BOLTS TYP.
2) 5/8"Ø x 2 1/2"
HEX BOLTS TYP.
SD-1
G
COMMON TRUSS
CONNECTION DETAIL
END
EXTERIOR TRUSS
2) 5/8"Ø x 2 1/2"
HEX BOLTS TYP.
2) 5/8"Ø x 2 1/2"
HEX BOLTS TYP.
SD-1
I
END TRUSS
CONNECTION DETAIL
COMMON PURLIN (P)
ATTACHED TO BOTTOM HOLES
SD-1
L
RIDGE PURLIN w/ KING PIN
CONNECTION DETAIL
RIDGE PURLIN (P)
ATTACHED TO TOP
HOLES
2) 5/8"Ø x 2 1/2"
HEX BOLTS TYP.
2) 5/8"Ø x 2 1/2"
HEX BOLTS TYP.
O U
T S
I D
E
D
G
1) RUBBER ENDFLAP PROTECTOR PN 949
(END TRUSSES ONLY) w/ 2) TEK3 x 1 1/4"
SCREWS & CURVED WASHERS PN 452
- INSTALL AFTER THERMA TAPE
COUPLER PROTECTOR - INSTALL
PRIOR TO THERMA TAPE
COUPLER PROTECTOR - INSTALL
PRIOR TO THERMA TAPE
ALL BAYS
NO PURLIN
REQUIRED AT
SIDE OF LEG
SD-1
J
LEG PURLIN(S)
CONNECTION DETAILS
STANDARD DETAILS 1
SD-1
THIS DRAWING IS PROPERTY OF BRITESPAN
BUILDING SYSTEMS INC.. ANY REPRODUCTION IN
WHOLE OR IN PART WITHOUT THE EXPRESSED
WRITTEN CONSENT OF BRITESPAN BUILDING
SYSTEMS INC. IS PROHIBITED. THIS DRAWING IS
NOT TO SCALE UNLESS OTHERWISE NOTED.
DRAWN BY:
CHECKED BY:
DATE:DESCRIPTION:REV #
JLK
PROJECT:
WIDTH-STEEL-FAB-HSS-HSSDROP:
DEALER: CUSTOMER:
ORDER ID:
SHEET NO.:
DRAWING TITLE:
PAGE NO.:
BRITESPAN OF THE PACIFIC NORTHWEST (BPNW)
18449 CASCADE AVENUE SOUTH
TUKWILA, WA. 98188
CITY OF SEATTLE FINANCE & ADMIN SERVICES
10503 INTERLAKE AVENUE NORTH
SEATTLE, WA. 98133
ATLAS 18.1
55'L6 x 40' - 320 GM
5' & 6' oc
SO# 7534
55L6-320-220-14-/
0 ISSUED FOR CONSTRUCTION 29.JUL.2020
1 2 REV. FABRIC FINISH TO 320 & REVISED PER 14.SEP.2020
CUSTOMER COMMENTS - JLK
2 REV. NOTES, DOORS & EW2 PER CUST., PURLINS ADDED - JIKH 02.OCT.2020
3 CR4-7 REVISED PER CUSTOMERS COMMENTS - NLW 14.JAN.2021
4 CR8 REVISED PER CUSTOMERS COMMENTS - NLW 01.FEB.2021
5 CR9 REVISED PER CUSTOMERS COMMENTS - NLW 02.FEB.2021
/14JIKH
TF: 800-407-5846
www.britespanbuildings.com
CR #
NOTE: NO POINT LOADS
ALLOWED ON PURLINS.
DOUBLE BRACED BAYS
U
T S
I D
E
D
G
SD-2
M CROSS CABLES AT DOGBONE
CONNECTION DETAILS
CROSS CABLE
ASSEMBLY
w/ SINGLE TAB
COMMON
TRUSS
1) 5/8"Ø x 3" HEX BOLT
END
TRUSS
CROSS CABLE
INSTALLATION POINT
O U
T S
I D
E
D
G
SD-2
N CROSS CABLES AT KINGPIN
CONNECTION DETAILS
NOTE:
- INSTALL ALL TURNBUCKLES AT ONE
END FOR EASE OF INSTALLATION.
TOP VIEW
SD-2
O CROSS CABLES AT LEG
CONNECTION DETAILS
CROSS CABLE ASSEMBLY
COMMON LEG END LEG
O U
T S
I D
E
D
G
DOUBLE BRACED END BAY
TOP VIEW
CROSS CABLE
ASSEMBLY
w/ DOUBLE TAB
DOUBLE BRACED BAYS
TOP VIEW
CROSS CABLE
ASSEMBLY
w/ SINGLE TAB
1) 5/8"Ø x 2 1/2" HEX BOLT
CROSS CABLE
INSTALLATION POINT
CROSS CABLE
ASSEMBLY
w/ DOUBLE TAB
COMMON
TRUSS
END
TRUSS
NOTE:
- INSTALL ALL TURNBUCKLES AT ONE
END FOR EASE OF INSTALLATION.
STANDARD DETAILS 2
SD-2
THIS DRAWING IS PROPERTY OF BRITESPAN
BUILDING SYSTEMS INC.. ANY REPRODUCTION IN
WHOLE OR IN PART WITHOUT THE EXPRESSED
WRITTEN CONSENT OF BRITESPAN BUILDING
SYSTEMS INC. IS PROHIBITED. THIS DRAWING IS
NOT TO SCALE UNLESS OTHERWISE NOTED.
DRAWN BY:
CHECKED BY:
DATE:DESCRIPTION:REV #
JLK
PROJECT:
WIDTH-STEEL-FAB-HSS-HSSDROP:
DEALER: CUSTOMER:
ORDER ID:
SHEET NO.:
DRAWING TITLE:
PAGE NO.:
BRITESPAN OF THE PACIFIC NORTHWEST (BPNW)
18449 CASCADE AVENUE SOUTH
TUKWILA, WA. 98188
CITY OF SEATTLE FINANCE & ADMIN SERVICES
10503 INTERLAKE AVENUE NORTH
SEATTLE, WA. 98133
ATLAS 18.1
55'L6 x 40' - 320 GM
5' & 6' oc
SO# 7534
55L6-320-220-14-/
0 ISSUED FOR CONSTRUCTION 29.JUL.2020
1 2 REV. FABRIC FINISH TO 320 & REVISED PER 14.SEP.2020
CUSTOMER COMMENTS - JLK
2 REV. NOTES, DOORS & EW2 PER CUST., PURLINS ADDED - JIKH 02.OCT.2020
3 CR4-7 REVISED PER CUSTOMERS COMMENTS - NLW 14.JAN.2021
4 CR8 REVISED PER CUSTOMERS COMMENTS - NLW 01.FEB.2021
5 CR9 REVISED PER CUSTOMERS COMMENTS - NLW 02.FEB.2021
/14
JIKH
TF: 800-407-5846
www.britespanbuildings.com
CR #
ENDFLAP
END TRUSS & BASE PLATE
BLOCK WINCH w/ ANCHOR BOLT
DESIGNED BY PSE & SUPPLIED BY
BPNW
END FLAP CABLE AROUND
THE TRUSS AND INTO THE
BLOCK WINCH
NOTE:
ENDFLAP WINCH CAN ALSO BE
INSTALLED ON FRONT FACE
OF FOUNDATION AS SHOWN IN
Q / SD-3.
SKIVE END FLAP COATING FROM STEEL
CABLE TO ENSURE STEEL CABLE IS FIRMLY
SECURED IN WINCH BEFORE TORQUING
PVC TUBE
GLUE BOTH ENDS
ROUND FASTENING TUBE
3) TEK5 x 1 1/2" SELF DRILLING SCREWS
SD-3
U
END FLAP CABLE & WINCH
CONNECTION DETAIL
LEFT HAND LASHING
WINCH (PN 319A)
USE COTTER PIN
(PN 456)
RIGHT HAND LASHING
WINCH (PN 318A)
USE COTTER PIN
(PN 456)
SD-3
T
UPDATED WINCH DETAIL USING
COTTER PIN TO HOLD RELEASE BAR
~6"
~9"
STD. 24" o/c
SPACING
TOP OF END WALL FABRIC TO
LINE UP WITH TOP OF OUTER
CHORD
CAMBUCKLES
Ø 1" PVC
SD-3
P
ENDWALL FABRIC @ PERIMETER PVC
CONNECTION DETAILS
SD-3
S
PVC / FASTENING TUBE
CONNECTION DETAILS
ZERO
BUFFER BOARD DESIGNED &
SUPPLIED BY BPNW
TERMINATION DESIGNED &
SUPPLIED BY BPNW
LASHING STRAP
ENDWALL COVER
320 STYLE APRON
(SHOWN AS CUSTOM ~8"
BELOW ZERO)
320 STYLE TENSION POCKET
(SHOWN AS STANDARD ~18"
ABOVE ZERO)
WINCH MOUNT (PN 228) w/
1) Ø 5/8" x 1 1/4" HEX BOLT
FOR BLOCK WINCH
Ø 2 7/8" FASTENING TUBE
SD-3
R
320 ENDWALL FABRIC
CONNECTION DETAIL
BUFFER BOARD DESIGNED &
SUPPLIED BY BPNW
ZERO POINT
320 STYLE APRON
(SHOWN AS CUSTOM
~8" BELOW ZERO)
TERMINATION DESIGNED &
SUPPLIED BY BPNW
2 7/8" Ø FASTENING TUBE
LASHING STRAP
BLOCK WINCH w/
ANCHOR BOLT DESIGNED
& SUPPLIED BY OTHERS
BUILDING COVER
320 STYLE TENSION POCKET
(SHOWN AS STANDARD
~18" ABOVE ZERO)
SECTION 'A-A'
SD-3
Q
320 STANDARD COVER
CONNECTION DETAIL
COMMON
LEG TRUSS
END
LEG TRUSS
SD-3
U
SD-3
CC
FASTENING TUBE
(INTERIOR VIEW)
END FLAP
CABLE
PVC TUBE
A
A
END FLAP WINCH w/
ANCHOR DESIGNED BY
PSE & SUPPLIED BY
BPNW
1" RATCHETS
w/BELTING
NOTE: 24" PVC NOTCHING
SD-3
CC
FASTENING TUBE SADDLE
CONNECTION DETAILS
FT END SADDLE BRACKET FOR RND. TUBE
2 7/8" CHORD - 2 7/8" PIPE = PN 207
1) 1/2" x 4" CARRIAGE BOLT (FIELD DRILL AS REQ'D)
2) TEK5 x 1 1/2" SELF DRILLING
SCREWS
2 7/8" Ø FASTENING TUBE
NO END CAP REQUIRED
END FLAP TO BE
WRAPPED AROUND
END TRUSS &
SECURED BY END
FLAP CABLE
STANDARD DETAILS 3
SD-3
THIS DRAWING IS PROPERTY OF BRITESPAN
BUILDING SYSTEMS INC.. ANY REPRODUCTION IN
WHOLE OR IN PART WITHOUT THE EXPRESSED
WRITTEN CONSENT OF BRITESPAN BUILDING
SYSTEMS INC. IS PROHIBITED. THIS DRAWING IS
NOT TO SCALE UNLESS OTHERWISE NOTED.
DRAWN BY:
CHECKED BY:
DATE:DESCRIPTION:REV #
JLK
PROJECT:
WIDTH-STEEL-FAB-HSS-HSSDROP:
DEALER: CUSTOMER:
ORDER ID:
SHEET NO.:
DRAWING TITLE:
PAGE NO.:
BRITESPAN OF THE PACIFIC NORTHWEST (BPNW)
18449 CASCADE AVENUE SOUTH
TUKWILA, WA. 98188
CITY OF SEATTLE FINANCE & ADMIN SERVICES
10503 INTERLAKE AVENUE NORTH
SEATTLE, WA. 98133
ATLAS 18.1
55'L6 x 40' - 320 GM
5' & 6' oc
SO# 7534
55L6-320-220-14-/
0 ISSUED FOR CONSTRUCTION 29.JUL.2020
1 2 REV. FABRIC FINISH TO 320 & REVISED PER 14.SEP.2020
CUSTOMER COMMENTS - JLK
2 REV. NOTES, DOORS & EW2 PER CUST., PURLINS ADDED - JIKH 02.OCT.2020
3 CR4-7 REVISED PER CUSTOMERS COMMENTS - NLW 14.JAN.2021
4 CR8 REVISED PER CUSTOMERS COMMENTS - NLW 01.FEB.2021
5 CR9 REVISED PER CUSTOMERS COMMENTS - NLW 02.FEB.2021
/14
JIKH
TF: 800-407-5846
www.britespanbuildings.com
CR #
**IMPORTANT**
PROTECT FABRIC
FROM CONTACT WITH
ALL SHARP EDGES
ZERO POINT
BUILDING COVER
SECTION 'A-A' INSULATION DETAIL
ZERO
ENDWALL COVER
ENDWALL INSULATION DETAIL
FABRIC LINER
DESIGN & SUPPLIED
BY BPNW
TERMINATION
DESIGNED BY
BPNW
2 LAYERS OF R-19, R-38 - INSTALLED
WITH STAGGERED JOINTS DESIGN &
SUPPLIED BY BPNW
ENSURE RIGID INSULATION
EXTENDS UP TO BATT INSULATION
DESIGN & SUPPLIED BY BPNW
3" THICK R-15 RIGID
INSULATION COVERED w/ FABRIC - DESIGN &
SUPPLIED BY BPNW
3" THICK R-15 RIGID
INSULATION COVERED w/
FABRIC - DESIGN &
SUPPLIED BY BPNW
ENSURE RIGID
INSULATION EXTENDS
UP TO BATT
INSULATION DESIGN &
SUPPLIED BY BPNW
2 LAYERS OF BATTS
- LAYER R-13
- LAYER R-13
w/ STAGGERED JOINTS -
DESIGN & SUPPLIED BY BPNW
TERMINATION
DESIGNED BY
BPNW
FABRIC LINER
DESIGN & SUPPLIED
BY BPNW
TENT INSULATION NOTES:
GENERAL NOTES:
1. IDENTIFICATION MARK SHALL BE APPLIED TO ALL INSULATION MATERIALS AND INSULATION INSTALLED SUCH THAT THE MARK IS READILY
OBSERVABLE DURING INSPECTIONS.
2. INSTALL 3" R-15 CONTINUOUS RIGID INSULATION ON STEM WALL AT EXTERIOR SIDE. TYPICAL FOR BOTH TENTS.
55X40 THREE BAY TENT:
A. INSULATION INSTALLATION IN THE ROOF AND ARCHED WALL AREAS WILL USE 1" SUSPENSION BANDS TO SUPPORT AND HOLD THE BATTS. THESE
BANDS WILL BE INSTALLED ON THE TOP OF THE LOWER CHORD HORIZONTALLY TRUSS TO TRUSS AT APPROXIMATELY 30" TO 36" INTERVALS. WE
WILL PUNCH HOLES IN THE BANDS AND THE 2 LAYERS WILL BE PINNED WITH STICK PINS AND LOCKING WASHERS TO SECURE THEM TO THE
BANDS. THE BUILDING WILL HAVE 2 LAYERS OF R-19, R-38 TOTAL. THE INSULATION LAYERS WILL HAVE STAGGERED JOINTS. SELF TAPPING
METAL SCREWS WILL BE USED TO ATTACH BANDS AND INSUL-HOLD PRODUCT INTO THE STRUCTURE FRAMING.
B. INSTALLATION IN ENDWALL AREAS WILL BE 2 LAYERS OF R-13 BATTS, INSTALLED WITH STAGGERED JOINTS. THE INSTALLATION WILL INCLUDE
USING THE METAL ROLLED INSUL-HOLD PRODUCT TENSIONED VERTICALLY WITH 2 RUNS PER 4' BATT. WE WILL ALSO USE THE STICK PINS AND
LOCKING WASHERS TO HELP SECURE THE BATTS INSTALLED IN PRE-PUNCHED HOLES IN THE ROLLED PRODUCT.
C. EXACTING DETAILS WILL PROVIDE ATTACHMENTS TO SATISFY INSTALLER'S PROPRIETARY METHODS THEY HAVE USED OVER THE PAST 20 YEARS.
POSSIBLE MINOR CHANGES AND OR SOME ADDITIONAL SECUREMENT MAY BE CALLED FOR BASED UPON JOB CONDITIONS REVEALED AS WE
ATTEMPT THIS INSTALL. ENDWALLS WILL CONTAIN ADDITIONAL 8" STUDS TO ALLOW FOR INSULATION WITHOUT COMPRESSION.
TERMINATION DESIGNED
BY BPNW
TERMINATION
DESIGNED BY
BPNW
STANDARD DETAILS 4
SD-4
THIS DRAWING IS PROPERTY OF BRITESPAN
BUILDING SYSTEMS INC.. ANY REPRODUCTION IN
WHOLE OR IN PART WITHOUT THE EXPRESSED
WRITTEN CONSENT OF BRITESPAN BUILDING
SYSTEMS INC. IS PROHIBITED. THIS DRAWING IS
NOT TO SCALE UNLESS OTHERWISE NOTED.
DRAWN BY:
CHECKED BY:
DATE:DESCRIPTION:REV #
JLK
PROJECT:
WIDTH-STEEL-FAB-HSS-HSSDROP:
DEALER: CUSTOMER:
ORDER ID:
SHEET NO.:
DRAWING TITLE:
PAGE NO.:
BRITESPAN OF THE PACIFIC NORTHWEST (BPNW)
18449 CASCADE AVENUE SOUTH
TUKWILA, WA. 98188
CITY OF SEATTLE FINANCE & ADMIN SERVICES
10503 INTERLAKE AVENUE NORTH
SEATTLE, WA. 98133
ATLAS 18.1
55'L6 x 40' - 320 GM
5' & 6' oc
SO# 7534
55L6-320-220-14-/
0 ISSUED FOR CONSTRUCTION 29.JUL.2020
1 2 REV. FABRIC FINISH TO 320 & REVISED PER 14.SEP.2020
CUSTOMER COMMENTS - JLK
2 REV. NOTES, DOORS & EW2 PER CUST., PURLINS ADDED - JIKH 02.OCT.2020
3 CR4-7 REVISED PER CUSTOMERS COMMENTS - NLW 14.JAN.2021
4 CR8 REVISED PER CUSTOMERS COMMENTS - NLW 01.FEB.2021
5 CR9 REVISED PER CUSTOMERS COMMENTS - NLW 02.FEB.2021
/14
JIKH
TF: 800-407-5846
www.britespanbuildings.com
CR #
4x8 HSS WINDPOST
BOTTOM CHORD
2) Ø5/8" x 5" HEX BOLTS
4x8 HSS BASEPLATE
PN 2372
2) Ø5/8" x 6" HEX BOLTS
HSS TOP SADDLE w/ TAB
PN 166
FRONT VIEW SIDE VIEW
O U
T S
I D
E
Ø5/8" x 4" CARRIAGE BOLT
PN 440
HSS TOP PLATE ASSY.
4x8/10 - PN 562
2) TEK5 x 1 1/2" SELF DRILLING
SCREWS
Ø5/8" x 2 1/2" HEX BOLT W/ 2) HEX NUTS
4x8 HSS WINDPOST
BOTTOM CHORD
2) Ø5/8" x 5" HEX BOLTS
HSS TOP SADDLE w/ TAB
PN 166
Ø5/8" x 4" CARRIAGE BOLT
HSS TOP PLATE ASSY.
4x8/10 - PN 562
2) TEK5 x 1 1/2" SELF DRILLING
SCREWS
Ø5/8" x 2 1/2" HEX BOLT W/ 2) HEX NUTS
V
4x8 HSS WINDPOST - 2 3/8" CHORD
CONNECTION DETAILS
ED-1
D
BD-1
DD
4x8 HSS WINDPOST - 2 3/8" CHORD
CONNECTION DETAILS
ED-1
ANCHOR BOLTS DESIGNED BY PSE
& SUPPLIED BY BPNW
4x6 HSS WINDPOST
BOTTOM CHORD
Ø5/8" x 4" CARRIAGE BOLT
PN 440
Ø5/8" x 7" CARRIAGE BOLT
BLOCK WINCH (L/R)
WINCH MOUNT ANGLE
PN 228
Ø5/8" x 1 1/4" HEX BOLT
4x6 HSS HEADER/BASE
ANGLE PN 2407
2) Ø5/8" x 6" HEX BOLT
HSS TOP SADDLE
PN 161
FRONT VIEW SIDE VIEW
O U
T S
I D
E
W
4x6 HSS WINDPOST - 2 3/8" CHORD
CONNECTION DETAILS
ED-1
E
BD-1
ANCHOR BOLTS DESIGNED PSE
& SUPPLIED BY BPNW
SECTION FRONT
8" HSS HEADER ANGLE
PN 2372
HSS VERTICAL
4"x8"x3/16" HSS HEADER
6) Ø5/8" x 5 1/2" HEX BOLTS
(FIELD DRILL AS REQUIRED)
X
8" HSS HEADER
CONNECTION DETAIL
ED-1
AA
ESS HORIZ. TO HSS VERTICAL
CONNECTION DETAILS
ED-1
O U
T S
I D
E
Ø 2 1/2" & Ø 2 7/8" ESS HORIZONTAL
Ø5/8" x 1 1/4" HEX BOLT
3) TEK5 x 1 1/2" SELF
DRILLING SCREWS
ESS HORIZONTAL ANGLE
PN 195
FRONT
MINIMUM OVERLAP
8"
KEEP ESS FLUSH
w/ O/S OF HSS
SECTION
3) TEK5 x 1 1/2" SELF
DRILLING SCREWS
TOP VIEW
USE MOST
CONVENIENT
HOLE
6) Ø5/8" x 5 1/2" HEX BOLTS
(FIELD DRILL AS REQUIRED)
4" HSS BASEPLATE ANGLE
PN 2805
HSS VERTICAL
4"x4"x1/8" HSS HEADER (EC-3)
Y
4" HSS HEADER
SECTION FRONT
CONNECTION DETAIL
ED-1
FRONT
4"x4"x1/8" HSS HEADER
4" HSS HEADER ANGLE
PN 189
6) Ø5/8" x 5 1/2" HEX
BOLTS (FIELD DRILL
AS REQUIRED)
HSS VERTICAL
Z
4" HSS HEADER
CONNECTION DETAIL
ED-1
2 1/2" SQUARE CHORD - Ø5/8" x 4" CARRIAGE BOLT
HSS TOP SADDLE
PN 7114
Ø5/8" X 5" CARRIAGE BOLT
BB
HEADER TO TRUSS
CONNECTION DETAIL
ED-1
4" X 4" HSS HEADER
OUTSIDE VIEW
OUTSIDE
BLOCK WINCH (L/R)
WINCH MOUNT ANGLE
PN 228
Ø5/8" x 1 1/4" HEX BOLT
2) 5/8" X 5" HEX BOLTS
FIELD DRILL AS REQ'D
ANCHOR BOLTS DESIGNED &
SUPPLIED BY BPNW
CC
DOOR ANGLE
TOP OF WALL TO HSS
ED-1
DOOR ANGLE
PN 4784
BLOCK WINCH (L/R)
WINCH MOUNT ANGLE
PN 228
Ø5/8" x 1 1/4" HEX BOLT
Ø5/8" x 6" HEX BOLT
FRONT VIEW SIDE VIEW
O U
T S
I D
E
ANCHORS DESIGNED &
SUPPLIED BY BPNW
ANCHORS DESIGNED &
SUPPLIED BY BPNW
ENDWALL DETAILS
ED-1
THIS DRAWING IS PROPERTY OF BRITESPAN
BUILDING SYSTEMS INC.. ANY REPRODUCTION IN
WHOLE OR IN PART WITHOUT THE EXPRESSED
WRITTEN CONSENT OF BRITESPAN BUILDING
SYSTEMS INC. IS PROHIBITED. THIS DRAWING IS
NOT TO SCALE UNLESS OTHERWISE NOTED.
DRAWN BY:
CHECKED BY:
DATE:DESCRIPTION:REV #
JLK
PROJECT:
WIDTH-STEEL-FAB-HSS-HSSDROP:
DEALER: CUSTOMER:
ORDER ID:
SHEET NO.:
DRAWING TITLE:
PAGE NO.:
BRITESPAN OF THE PACIFIC NORTHWEST (BPNW)
18449 CASCADE AVENUE SOUTH
TUKWILA, WA. 98188
CITY OF SEATTLE FINANCE & ADMIN SERVICES
10503 INTERLAKE AVENUE NORTH
SEATTLE, WA. 98133
ATLAS 18.1
55'L6 x 40' - 320 GM
5' & 6' oc
SO# 7534
55L6-320-220-14-/
0 ISSUED FOR CONSTRUCTION 29.JUL.2020
1 2 REV. FABRIC FINISH TO 320 & REVISED PER 14.SEP.2020
CUSTOMER COMMENTS - JLK
2 REV. NOTES, DOORS & EW2 PER CUST., PURLINS ADDED - JIKH 02.OCT.2020
3 CR4-7 REVISED PER CUSTOMERS COMMENTS - NLW 14.JAN.2021
4 CR8 REVISED PER CUSTOMERS COMMENTS - NLW 01.FEB.2021
5 CR9 REVISED PER CUSTOMERS COMMENTS - NLW 02.FEB.2021
/14JIKH
TF: 800-407-5846
www.britespanbuildings.com
CR #
| Sheets and Views |
| SO-7534-A18.1-55L6X40-City of Seattle-STRUCTURAL-R5-Cover US |
| SO-7534-A18.1-55L6X40-City of Seattle-STRUCTURAL-R5-BP |
| SO-7534-A18.1-55L6X40-City of Seattle-STRUCTURAL-R5-BD-1 |
| SO-7534-A18.1-55L6X40-City of Seattle-STRUCTURAL-R5-Iso |
| SO-7534-A18.1-55L6X40-City of Seattle-STRUCTURAL-R5-PURLIN |
| SO-7534-A18.1-55L6X40-City of Seattle-STRUCTURAL-R5-Bracing-Plan |
| SO-7534-A18.1-55L6X40-City of Seattle-STRUCTURAL-R5-Bracing-Ele. |
| SO-7534-A18.1-55L6X40-City of Seattle-STRUCTURAL-R5-EW- 1 |
| SO-7534-A18.1-55L6X40-City of Seattle-STRUCTURAL-R5-EW 2 |
| SO-7534-A18.1-55L6X40-City of Seattle-STRUCTURAL-R5-SD-1 |
| SO-7534-A18.1-55L6X40-City of Seattle-STRUCTURAL-R5-SD-2 |
| SO-7534-A18.1-55L6X40-City of Seattle-STRUCTURAL-R5-SD-3 |
| SO-7534-A18.1-55L6X40-City of Seattle-STRUCTURAL-R5-SD-4 |
| SO-7534-A18.1-55L6X40-City of Seattle-STRUCTURAL-R5-ED-1 |
File details come from the government source that posted it. Updated .