Salient Characteristics S22054

PORTABLE SPECTRORADIOMETER SYSTEM

Salient Characteristics

1 ea. Spectroradiometer:

1. The system shall consist of a self-contained, stand-alone, Field Portable Spectroradiometer and accessory equipment as described below.

2. Shall be a Visible Near Infra-Red (VNIR) type unit capable of operating in the spectral range from 350 to 1050 nm range.

3. Shall be capable of operating in a field or laboratory environment.

4. Shall include a built-in, touchscreen, sunlight readable, graphical LCD display.

5. Shall include built-in GPS with the ability to record longitude, latitude, and time of each spectral reading.

6. Shall include Foreoptic with at least an 8-degree Field-of-View (FOV).

7. Shall include a built-in camera.

8. Shall include Bluetooth communications for interfacing to a laptop or PC.

9. Shall have a bandwidth of less than or equal to 1.5 nm at 700 nm.

10. Shall include a NIST traceable calibration accuracy of +/-5% at 400 nm and 4% at 700 nm, or better.

11. Shall be capable of operating the instrument with the use of an external computer.

12. Shall have a Full Width Half Maximum (FWHM) resolution less than or equal to 3.2 nm at 700 nm, or better.

13. Shall incorporate the use of 100% linear array technology.

14. Shall be capable of storing at least 1,000 spectral readings.

15. Shall include a detachable, rechargeable, Lithium-ion type battery. Battery shall be capable of providing at least 8 hours of operation on a full charge.

16. Shall include a hand strap and be capable of being mounted on a tripod.

17. Shall include a second Bluetooth communication interface that allows optional communication with external sensors.

18. Shall have USB and RS-232 communication interfaces.

19. Shall include a ruggedized, water-tight, field case for housing and transporting the instrument and accessories.

20. Shall include all required accessories such as, but not limited to, communication cable(s), battery charger and cable, software program(s), calibration data, and manual.

Required Optional Equipment

1 ea. Fiber Optic Light Guide

21. Shall have 25-degree Field of View capability and a cable of at least 1.15 m long.

1 ea. Reflectance Panel

22. Shall be no larger than 5” x 5” with 10% reflectance.

23. Shall be calibrated and enclosed in an aluminum frame.

140G0122Q0100 - USGS Page 1 of 2

Salient Characteristics S22054

1 ea. Radiometric Calibration

24. Shall include radiometric calibration for the fiber optic light guide.

1 ea. Foreoptic Device

25. Shall consist of a hand-held device with adapter and actuator.

26. Shall be capable of attaching the foreoptic and the fiber optic light guide.

1 ea. Battery

27. Shall include 1 ea. additional Li-ion battery compatible with the Spectroradiometer.

28. Shall be detachable, rechargeable, Lithium-ion type battery capable of providing at least

8 hours of operation on a full charge.