B08_Solicitation_Attachment_2_Equipment_Cut_Sheets.pdf

PDF 26 MB Posted

Attached to
THOMAS STONE NHS - RENOVATE VIS. CTR. RESTROOMS Federal contract opportunity
Solicitation number
140P4325R0030
Issued by
Department of the Interior National Park Service Northeast Region

About this file

This file is a technical product specification sheet for an American Specialties, Inc. Baby Changing Station (Model #9013), a recessed stainless steel unit designed for public restroom facilities. The device is ADA-compliant, supports infants up to 3 years old weighing up to 50 lbs, and features a high-impact-resistant plastic changing surface, two integral bag hooks, a bed liner dispenser, and an adjustable two-part safety strap. Key technical specifications include a satin finish Type 304 stainless steel construction, counterbalanced gas spring mechanism for one-handed operation, and tested durability to sustain a 300 lbs static load with minimal deflection.

The product is designed with multiple safety and accessibility features, including ADA, ASTM, ANSI, and international compliance standards. Installation requirements specify a rough wall opening of 34-1/4" W x 22-3/4" H x 3-3/4" D, with mounting height between 32" to 32-3/8" above finished floor. The unit comes with a five-year warranty and includes safety warnings in multiple languages, emphasizing proper child supervision during use. Additional features include a concealed spring mechanism, vandal-resistant design, and compatibility with various bathroom configurations.

View the file

Other files for this federal contract opportunity

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Scan for Information

Technical Data Sheet

Product overview ADA-compliant unit features welded stainless steel for long and reliable use. Exposed surfaces are satin finish. Easy one-handed operation is assisted by a pull handle and concealed spring. The changing surface is high-impact-resistant plastic for easy cleaning. Its two part adjustable safety strap and 50 lbs (23 kg) load capacity assure child protection. Tested during development to sustain 300 lbs (136 kg) static load with minimal deflection.

Baby Changing Stations

Key Features & sPeciFications

• ADA, ASTM F-2285 & F-2388, G-21, G-22, ANSI Z535, ANSI 117.1, EN 1222-1, and EN 1221-2 (Including A1:2013) compliant.

• Includes contoured pull handle, two integral bag hooks and a bed-liner dispenser (convertible to a multi-fold towel dispenser).

• Robust door (16 gauge) and cabinet (18 gauge) are made from Type 304 Stainless Steel - Satin Finish.

• The changing surface is high-impact-resistant plastic for easy cleaning.

• Recessed Mounting. Designed to support an infant up to 3 ½ years old and a weight up to 50 lbs (23 kg).

• The bed is designed to cradle a child's body. An adjustable two-part, vinyl-coated safety strap with a Sure-Lock latch aids in safety.

• Unit shall include two bag hooks, bed liner dispenser, and a C-fold towel and multi-fold towel dispenser which can easily be converted to a multi-fold towel dispenser that needs no adapters.

American Specialties, Inc. | 441 Saw Mill River Road, Yonkers, NY 10701 | (914) 476-9000 | www.americanspecialties.com Model:#9013 Issued: 11/1/2021 Revised: 4/25/2024

Page: 1 of 2 Revision: R8

13" [330]25-1/2"

[648]

32" [813]

9-1/16" [230]

22-1/4" [565]

3/8" [9]

17-3/4" [451]

17-3/4" [451]

REF

COMFORTABLE - EASY TO USE.

WARNING

AVERTISSEMENT WARNUNG

ADVERTENCIA

Never leave child unattended.

Avoid serious injury from falling or sliding out.

Always use restraint system.

Designed for Infants Only. Age up to 3.5 years and weighing less than 50 lbs.

Keep one hand on child at all times.

Lassen sie ihr kind nie ohne aufsicht Verhindern sie ein herunterfallen oder herausrutscchen, was zu ernsthaften verletzungen fuhren kann.

Halten sie ihr kind stets mit einer hand fest.

Sicherheitsgurt immer anwenden.

Geeignet fur sauglinge und kleinkinder bis

3.5 jahren und einem gewicht bis zu 23 kg.

Nunca deje el nino desatendido.

Evite lesiones serias de ca das o por resbalamiento.

Siempre utilice las correas.

Disenado solamente para infantes. Hasta tres anos y medio y que pesen menos de 50 libras.

Siempre mantenga una mano sobre el nino.

Ne jamais laisser un enfant sans surveillance.

Evitez les blessures serieuses causees par le glissement.

Gardez une main sur l'enfant en tout temps.

Toujours ultilser le system d'attaches.

Concue pour les jeunes enfants seulement d'age jusqu'a 3.5 ans et pesant moins de 50 lbs (23kg).

37" [940] 32" [813]

TO

32-3/8" [822]

AFF

33-3/4" [857]

1-3/8" [35]

13" [330]

7-7/16" [189]

4" [102]

RWO - 34-1/4"W [870] x 22-3/4"H [578]

BAG HOOK

(2)

BED LINER

DISPENSER

PAPER TOWEL

DISPENSER

ADJUSTABLE SAFETY

STRAP AND CAM BUCKLE

FINISHED WALL

FINISHED FLOOR

PULL HANDLE

CL

RECESSED HANDLE

PULL, BLACK PLASTIC

47-5/8" [1207]

TO

48" [1219]

AFF

26-13/16" [681]

TO

27-3/16" [691]

AFF

2-1/4" [57]

2-3/4" [70]

CL

CL CL

CL

CL

CL

3-9/16" [91] sustainability/leed

BABY CHANGING STATION – STAINLESS STEEL, RECESSED

1Toilet AccessoriesCSI:10 28 13

Model #9013

MasterFormat Section 10 28 13

MR 4.1 (1)

MR 4.2 (1)

MR 6 (1)

EQ 4.1 (1)

EQ 4.2 (1)

EQ 4.4 (1) NOTE:

ALL DIM’S INCH [MM]

ILLUSTRATION FOR REF ONLY AND NTS

oPeration & Maintenance technical inForMation / Product ProPerties installation warranty

Technical Data Sheet Model #9013

Provide Rough Wall Opening 34-1/4" W x 22-3/4" H x 3-3/4" D minimum [870 x 578 x 95] from face of finished wall. Mount unit in wall opening using either four (4) #10 x 1-1/2" [38] long self-threading screws through side holes or four (4) 3/8" x 2" [10 x 51] lag screws (or other fasteners appropriate for wall conditions, not supplied) through mounting holes in rear wall of cabinet. Use washers and snap covers provided. For compliance with 2010 ADA Accessibility Standards install unit so that top edge of changing table is 32" to 32-3/8" [813 to 822] Above Finished Floor (AFF). See installation instructions packed with unit.

Rough Wall Opening (RWO) required is 34-1/4" W x 22-3/4" H x 3-3/4" D minimum [870 x 578 x 95]

Manufacturer reserves the right to make changes to the design, dimensions or functionality of the product without formal notice.

Pull down changing table is counterbalanced with a damped gas spring and can be opened or closed with one hand. Unit is operable with less than 5 Lbf (22.2N) while not requiring any tight grasping, pinching or twisting of the wrist. Secure the child in place by using child protection safety strap. The safety strap and cam buckle are assembled by sliding the safety strap into the cam buckle until it is snug on child. Tighten or loosen the strap by pulling the strap end through and clamping the buckle. To unbuckle the strap simply lift the buckle lever.

Five (5) Years from date of Invoice

American Specialties, Inc. | 441 Saw Mill River Road, Yonkers, NY 10701 | (914) 476-9000 | www.americanspecialties.com Model:

CSI:

#9013 10 28 13 Toilet Accessories

Issued: 11/1/2021 Revised: 4/25/2024 Page:

Revision:

Supports an infant up to 3 ½ years old and a weight up to 50 lbs (23 kg). Tested during development to sustain 300 lbs (136 kg) static load with minimal deflection.

Property Value

Dimensions

Construction

Recessed

R8

Type 304 Stainless Steel - Satin Finish

Closed: 37" x 25-1/2" x 3/8" [940 x 648 x 10] Open: 37" x 25-1/2" x 17-3/4" [940 x 648 x 451]

Mounting

Capacity

*740158* 740158

General

The Benchmark is an automatic electromechanical swinging door operator for use on hinged, center pivoted and offset pivoted doors.

When activated, the Benchmark drives the door to full open position, then electrical power is turned off and the door is closed by spring force. The activating circuit opens the door from any position in the closing swing. During a power failure, the Benchmark acts as a manual door closer (Size 3). Door opening and closing cycles, including opening speed, back check speed, hold open time delay, closing speed, and latch position, are adjustable.

WARNING

Always disconnect main power to the operator prior to servicing or cleaning.

CAUTION

This operator is for indoor use only.

Do not mount any accessories directly to the operator.

Replacement Parts & System Components

Part 27” Header Full Length Header Single

Full Length Header Double

Premium Control Box

9130-3462SC

9140-3462SC

9130-3462SC

9140-3462SC

9150-3462SC

Gear Box 9130-3454S 9140-3554S

9130-3454 9140-3454

9150-3454S

End Caps 9130-334 9140-334 9150-334

Part Pull Standard Push Extended Reveal Push

Finish

Arm Assembly 9130-3077T 9140-3077 9150-3077

9140-3077L 9150-3077L

US28

DC13

Table of Contents

General Replacement Parts & System Components Replacement Parts & System Components (Cont.)

1 Pre-Installation Site & Product Check 2 Operator Installation 3 Wiring 4 Arm & Cover Installation 5 Operational Check 6 Operator Adjustment 7 Release for Service 8 Benchmark III Software

Swing Operator Models 9130, 9140 & 9150

Benchmark III Installation Instructions

Replacement Parts & System Components (Cont.)

Double Push System

(Screw pack not shown)

1 Pre-Installation Site & Product Check 1a Check that the Product Model is correct for the required application.

1b Check that all parts listed on the Bill of Material are in the shipping container.

1c Check the architectural drawings and final approved shop drawings for the position of frame and structural openings.

1d Check header and frame dimensions and required clearances.

1e Check Door Width:

a. 26” minimum for 27” Push Operator

b. 30” minimum for 27” Pull Operator

c. 36” minimum for Full Length Push or Full Length Pull Operators

1f Check that Door Weight is 200 lbs. or less. For heavier door, consult factory.

1g Check that a 115 volt, single phase, 60 Hz, fused 15 amp, 3-wire power supply is available at the side jamb with approximately 12” of wire available to connect to the Operator. UL approved flexible conduit is recommended for the 115 volt power line.

The 115 volt power supply must be a dedicated circuit from the main circuit breaker panel and must NOT be connected into any building lighting system that operates flourescent lights.

2 Operator Installation 2a Remove Control Box from Operator Mounting Bracket, then remove Motor/Gearbox from Bracket:

Control Box and Motor/Gearbox Removal 27” Pull, 27” Push, and Double Push Systems

Control Box and Motor/Gearbox Removal Full Length Pull and Full Length Push Systems

2b Prepare Header/Frame and Door:

a. 27” Pull System ....................................................................................................................................................Page 6

b. Full Length Pull System .......................................................................................................................................Page 6

c. 27” Push System..................................................................................................................................................Page 7

d. Full Length Push System .....................................................................................................................................Page 7

e. Double Push System ...........................................................................................................................................Page 8

f. Low Ceiling Application ........................................................................................................................................Page 8

NOTE

For Push Units with a Reveal greater than 6” refer to the installation sheet included in the Extended Arm package.

2c Install Operator Mounting Bracket on Header/Frame. For Full Length systems, also install Switch Bracket on Header/ Frame.

2d Install Motor/Gearbox on Operator Mounting Bracket. Then install Control Box on Bracket.

2e Proceed to Chapter 3: Wiring (Page 9).

27” Pull System Header/Frame and Door Preparation

Full Length Pull System Header/Frame and Door Preparation

Center Operator Cover (with End Caps removed) over opening and mark a vertical line at each end. Align ends of Operator Mounting Bracket and Switch Bracket with vertical lines and adjust vertical position per diagram below. Mark and prepare mounting holes.

27” Push System Header/Frame and Door Preparation

Full Length Push System Frame/Header and Door Preparation

Center operator cover (with end caps removed) over opening and mark a vertical line at each end. Align ends of operator mounting bracket and switch bracket with vertical lines and adjust vertical position per diagram below. Mark and prepare mounting holes.

Double Push System Header/Frame and Door Preparation

Center operator cover (with End Caps removed) over opening and mark a vertical line at each end. Align ends of Operator Mounting Bracket and Switch Bracket with vertical lines and adjust vertical position per diagram below. Mark and prepare mounting holes.

Low Ceiling Application (27” Push System Only) Header/Frame and Door Preparation

3 Wiring

CAUTION

Make sure all wires are properly dressed and secured to prevent interference.

Route all wiring away from moving parts, sharp edges, and heat sources.

Use copper conductors only.

Do not modify the factory wiring or connect into existing electrical circuits or devices.

3a Refer to the appropriate wiring diagram for the Control Box (Page 19) or the diagram supplied for custom applications.

Connect the following cables:

• Ground Cable (Ground the Operator properly with the earth from main supply)

• Hall Effect Cable (Do not wrap the Hall Effect Cable around the Motor Power Cable)

• Motor Power Cable (Do not wrap the Motor Power Cable around the Hall Effect Cable)

• Control Box Power Cable

3b Connect Activate, Safety, Key Switch, and lock accessories, as needed.

Refer to the accessory instructions for any accessories used. Do not connect any remote activating device to the door unless it is located within line of sight of the door.

3c When wiring is complete, proceed to Chapter 4: Arm and Cover Installation (page 10).

4 Arm & Cover Installation

CAUTION

Keep hands, clothing, wires, tools, etc., AWAY FROM Operator Motor when the Operator Motor is turned on.

4a Make sure the Operator Powers is turned Off.

4b Install a jumper across the control box Main Act and Main Act.

4c Turn the operator power switch to On.

The operator motor will activate and drive to the Full Open position.

4d Attach the arm to the operator spindle loosely with the 8mm socket head screw.

For push systems, ensure that the adjusting boss is inserted correctly.

4e Attach the arm to the door.

1. For push systems, attach the push arm shoe to the door:

2. For pull systems, slide the pull arm roller into the track, then insert a track cap on each end of the track and attach the track to the door:

Pull Arm

Pull Arm Push Arm

Pull Arm

4f Adjust arm:

1. For pull systems, remove the locking screw from the arm.

2. For push system, remove the locking screw from the arm.

Pull Arm

3. Keep the door in the full open position and adjust the arm length as necessary to align the door at 90 degrees from closed.

When the arm is adjusted to the correct length, tighten the 8mm socket head screw that secures the arm to the operator spindle.

4. Ensure this screw is secure, then tighten the arm locking screw.

4g Turn Off the power operator switch. The door should close.

4h Remove the jumper from the control box Main Act and Main Act.

4i Test the operator (see Chapter 5: Operational Check on page 13).

4j Adjust the operator as required (see Chapter 6: Operator Adjustment on page 15).

4k Snap the optional end cap insert (in bag of screws) into end cap opposite the On/Off switch.

4l Install the cover assembly onto the operator.

4m Release the operator for service (see Chapter7: Release for Service on page 17).

5 Operational Check 5a Set the key switch to Auto (if used) and turn on the operator power switch.

5b Activate the operator using the activation device.

The operator will perform one sizing cycle.

Sizing cycle: Occurs after power is turned on and a legitimate activation signal is received. During the sizing cycle, the door opens and closes one time.

5c If the Door does NOT OPEN AT ALL during the sizing cycle:

• Check the door for binding.

• If an electromechanical lock is being used, check that the lock disengages before the operator opens the door.

• Check fuses, circuit breakers and connections.

• Adjust the operator and check the door operation (see Chapter 6: Operator Adjustment on page 15).

Below are default settings:

Opening Speed ............................................................................................................... 9:00 Back Check Speed ......................................................................................................... 3:00 Hold Open Time Delay .................................................................................................... 10:00 Latch Position ................................................................................................................. 12:00 Closing Speed................................................................................................................. 12:00 SW1 1, 2, 3, 4 ................................................................................................................. OFF Back Check Position ....................................................................................................... 4:00 (fully clockwise)

5d If the door does NOT OPEN FULLY during the sizing cycle:

• Check the door for binding.

• Increase the back check speed slightly and re-check the door operation. Repeat until door opens fully.

5e If the door SLAMS OPEN during the sizing cycle, decrease the back check speed slightly and re-check the door operation. Repeat until the door opens without slamming.

5f After the sizing cycle is completed and the door(s) are closed, apply a maintained activation signal. Check that the door remains open while the signal is applied.

5g If a door safety device is being used:

1. Door Open Safety:

When the door is in the closed position, activate the safety device and try to activate the door open. The door should remain closed.

2. Door Close Safety:

When the door is in fully open position, activate the safety device and the door should remain open.

5h When the door is operating properly, continue with step 4j above.

6 Operator Adjustment

See table below and diagrams (page 16) for operator feature adjustment.

After adjusting, cycle the door several times to check for proper operation. Then continue with step 4k on page 9.

NOTE

Adjust Operator for the SLOWEST operation practical, in accordance with the latest revisions of the Americans with Disabilities Act (ADA); ANSI/BHMA A156.19 Standards for Power-Assisted and Low Energy Power-Operated Doors; and local codes.

Opening Speed: 5 seconds or more Closing Speed: 3 seconds or more

Latch Location: 10 degrees or more Latch Speed: 1.5 seconds or more

Features Control Description Counter Clockwise

Clockwise

Opening Speed

Opening Speed Controls opening speed of door Slower Faster

Back Check Speed

Back Check Speed Controls the speed of the door near the full open position to prevent door slamming

Slower Faster

Hold Open Time Delay

Hold Open Time Delay Controls the length of time the door remains in the full open position: 1 sec to 15 sec

Less Time Down to 1 sec

More Time Up to 15 sec

Back Check Position

Back Check Position Door position where back check speed engages

Less Latch More Latch

Closing Speed Closing Speed Controls closing speed of door Slower Faster Delayed Activation

DLY (SW1) Delays opening of door for strike applications (1 second delay)

Push and Go PNG (SW2) ON: Pushing the door open 5° causes operator to open door for remainder of open cycle

Power Boost On or Off

PB (SW3) ON: 3-second power boost enabled:

applies additional force to close door— used for high wind situations

SW4 Not used

Less More

Backcheck Position

Latch Position

MoreLess

Less More

Open Speed

Time Delay

MoreLess

Backcheck Speed

MoreLess

Less More

Close Speed

OFFON

PB

PNG

DLY

7 Release for Service 7a Remove all tools, installation equipment and debris from the vicinity of the door.

7b MANDATORY: Install all Safety, Traffic Control and Instruction Labels onto the door, as required. Failure to do this will leave the INSTALLER LIABLE for any accidents that occur.

7c Give verbal instruction on how to properly operate the door to the owner or person in charge.

7d Give verbal instruction to the owner or person in charge on periodic inspection of the door for the following:

• Occasional damage

• Developing problems

• Minor preventative maintenance

7e Provide the owner or person in charge with a contact name and phone number to call for future service and maintenance.

IMPORTANT

Be sure to install all Safety, Traffic Control and Instruction Labels onto the door, as required.

8 Benchmark III Software 8a Operation:

1. Sizing

From start-up (Sizing), the door will activate via:

• 1-Way Input (Main Act and Main Act).

• 2-Way Input (3-Way OFF, 3-Way HO and 3-Way GND) with key switch in the ON position, uses either Main Act or Aux Act input

• Key switch in Hold Open position.

The first motion of the door will be towards the Door Open position. The speed during Sizing is automatic and cannot be set from a potentiometer.

The door drives to full open and the system sets the open counter to full open.

The door closes at Closing Speed. The system sets the closed counter to Full Closed when the latch goes up at the Closed position.

The system calculates all other parameters required for normal operation based on the two values of Full Open and Full Closed.

2. Standard Operation Upon a legitimate activation signal, the door accelerates to opening speed while monitoring the current load on the drive output. If the current exceeds the specified level, the door will stop and close.

The door travels at it’s set speed (based on the potentiometer setting) until it reaches the Back Check position, where it will decelerate to the Back Check Speed.

The door will stop at the Hold Open position and remain there until an activation or the Hold Open Timer is cleared.

The door then closes at its Closing Speed (based on the potentiometer setting) up to the latched position.

If the Closing Speed is decreased by driving the motor in the open direction (a fixed setting), power is added to allow the spring to continue closing the door to the Full Closed position.

© Allegion 2024 Printed in U.S.A.

740158 Rev. 03/24-g

24VDC -

24VDC +

Safety Sen

Safety GND

Relay Com

N/O Strike Relay

N/C Strike Relay

Aux GND

Aux ACT

3 Way HO

3 Way GND

3 Way OFF

Main Act

Main Act

Electric Lock, Electric Strike, etc.

N.O. or N.C.

Depending on Device

Black DC-

Red DC+

Activation Device N.O.

Dry ContactsRed Black Green

Activation Device N.O. Dry Contacts

Multiple activation devices should be connected in parallel

Control box grounding stud

For clarity, not all components are shown on the control box PC board J8, 10-position Control Box Power Cable

J1, 6-position Main Power Cable

J5, 2-position Motor Power Cable

J3, 4-position Hall Effect Cable

Plug cables into these receptacles

Connect Fail Safe to N/C Fail Secure to N/O

Disabled when optional 3 position switch is in Off position

Optional 3 Position

Switch

Connection to external devices must be made using CL2, CL2P, CL2R, or CL2X Class 2 wire or equivalent.

TLX-2

Express® Lavatory System – TLX Series

© 2024 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309

800 BRADLEY (800 272 3539) +1 262 251 6000

bradleycorp.com

Page 1 of 15 2/19/2024 This information is subject to change without notice.

Bradley_Sink_Express_TLX-2

View Latest Version

Key Features x Seamless, one-piece lavatory is a cost effective upgrade to traditional fabricated counters with seams x With fewer plumbing connections, installs faster than traditional counters & sinks x Easy-to-clean, linear design minimizes flat areas where water could puddle x 1 person access panel install and removal x ADA and TAS compliant x Available in a variety of Terreon® solid surface colors x Compatible with WashBar® Duo and Verge™ deck-mounted soap dispensers and faucets

Specifications Accommodates one or two users. These units handle washroom traffic quickly and economically. Robust design meets or exceeds the ANSI load requirements. This system can be mounted at different heights to accommodate hand washing for adults, children, young children, and those with disabilities. Meets Enhanced Reach when paired with WashBar Duo. Search CSI 3-part specification on bradleycorp.com for CSI spec format.

This plumbing fixture is designed for hand washing only. It is not intended to dispense water for human consumption through drinking or for preparation of food or beverages.

Complies with x ADA x ICC/ANSI 117.1 x TAS x Enhanced Reach IC A117.1, 606.5 (WashBar Duo) x NSF/ANSI 372 x CSA B45.5/IAPMO Z124

Product Compliance Listed by IAPMO R&T to x Uniform Plumbing Code (UPC) x National Plumbing Code of Canada x International Plumbing Code (IPC) x IGC 156 x IGC 127 (WashBar)

Listed by UL Environment to x GreenGuard Gold

Shown with Verge Soap & Faucet

Compatible Bradley Products x Verge Coordinated Soap and Faucet x WashBar Duo

* PVD Finishes Physical Vapor Deposition is an intricate, environmentally friendly finishing process that molecularly bonds the finish to the faucet, creating a very hard, durable surface that will not corrode, discolor, or tarnish.

Finishes

Polished Chrome

Brushed Black Stainless*

Brushed Stainless*

Brushed Bronze*

Brushed Brass*

Brushed Nickel*

*PVD Finishes, see PVD Finishes section.

Click on any color swatch to view as a larger image.

Sustainability x Terreon participates in the mindful MATERIALS library https://www.bradleycorp.com/mediamanager/view/26592/Bradley_Sink_Express_TLX-2.pdf https://www.bradleycorp.com/mediamanager/view/26592/Bradley_Sink_Express_TLX-2.pdf https://www.bradleycorp.com/product-category/verge-coordinated-soap-and-faucet https://www.bradleycorp.com/product-category/washbar-duo https://www.bradleycorp.com/mediamanager/view/25548 https://www.bradleycorp.com/mediamanager/view/25547 https://www.bradleycorp.com/mediamanager/view/25544 https://www.bradleycorp.com/mediamanager/view/25543 https://www.bradleycorp.com/mediamanager/view/25545 https://www.bradleycorp.com/mediamanager/view/25546

© 2024 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309

800 BRADLEY (800 272 3539) +1 262 251 6000

bradleycorp.com

Page 2 of 15 2/19/2024 This information is subject to change without notice.

Bradley_Sink_Express_TLX-2

View Latest Version

Construction Basin Constructed of Terreon, a densified solid surface material composed of a bio-based resin. Terreon is resistant to chemicals, stains, burns, and impact. Surface damage can be easily repaired with every day cleansers or fine grit abrasives. Terreon is GREENGUARD® certified as low-emitting materials.

Support Bracket Bracket design allows for flexible stud or wall blocking anchor locations. Eliminates the need for in-wall carriers. IAPMO certified to meet or exceed ANSI load requirements.

Access Panel Unique access panel design pivots on stainless steel brackets which easily allows for one person installation and removal. Standard thumb screw fasteners and vandal-resistant fasteners included as standard. The access panel is composed of high impact polymer so it will not chip, peel or flake. The fully enclosed vandal-resistant design eliminates the need for plumbing wrap.

Strainer and Drain Assembly System comes complete with 300 series stainless steel strainers, tailpiece connection and one drain rough-in with one drain connection.

Vandal Resistance Water supplies, valving, waste assembly and other optional items are completely concealed within the high impact resistant access panel. Vandal-resistant access panel fasteners included as standard. Terreon bowl material is also highly vandal resistant and repairable.

Faucets* Choose from our 0.35 gpm (1.30 Lpm), 0.05 gpc (0.25 Lpc) or 0.50 gpm (1.90 Lpm), 0.09 gpc (0.35 Lpc) Verge Faucets – Crestt, Metro, Linea, or Zen Series.

Available in 0.35 gpm (1.30 Lpm), 0.05 gpc (0.25 Lpc) or 0.5 gpm (1.90 Lpm),

0.09 gpc (0.35 Lpc), WashBar Duo WBD1 includes soap dispenser and faucet in a single piece casting. Verge faucets and WashBar Duo come as chrome-plated with optional in-stock PVD finishes. Also available are 4" centerset, 8" centerset, and centershank faucet drillings are available for faucets by others. Optional 4" centerset trim plates are available for additional vandal resistance.

Soap Dispensers* Choose from our Verge Deck-Mounted Soap Dispensers – Crestt, Metro, Linea, or Zen Series. Soap drillings available for soap by others. Also available with WashBar Duo WBD1, foam or liquid soap. WashBar Duo accommodates a 1 gallon cylindrical soap container, provided by others. Verge soap dispensers and WashBar Duo come as chrome-plated with optional in-stock PVD finishes.

*For primary/elementary school applications, Bradley recommends hands-free activation for soap dispensers and faucets in lieu of manual activation to ensure proper reach for kindergarten students. TLX-2 meets Enhanced Reach requirements when paired with WashBar Duo WBD1.

https://www.bradleycorp.com/mediamanager/view/26592/Bradley_Sink_Express_TLX-2.pdf

© 2024 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309

800 BRADLEY (800 272 3539) +1 262 251 6000

bradleycorp.com

Page 3 of 15 2/19/2024 This information is subject to change without notice.

Bradley_Sink_Express_TLX-2

View Latest Version

Top View (shown with Verge Soap & Faucet) (mm)

(mm)Front View (shown with Verge Soap & Faucet)

20⁵⁄₈" (525)

6" (152) 6" (152)

2⁹⁄₁₆" (65)

5¹⁄₈" (130)

55⁵⁄₁₆" (1404)

25⁵⁄₁₆" (642)15" (381)

47¾" (1213)

34" (864)

19¹⁄₈" (486)

Finished Floor

© 2024 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309

800 BRADLEY (800 272 3539) +1 262 251 6000

bradleycorp.com

Page 4 of 15 2/19/2024 This information is subject to change without notice.

Bradley_Sink_Express_TLX-2

View Latest Version

Top View (shown with WBD1) (mm)

(mm)Front View (shown with WBD1)

20⁵⁄₈" (524)

4" (102)5" (127)

55⁵⁄₁₆" (1404)

25⁵⁄₁₆" (642)

15" (381)

47¾" (1213)

7¹⁄₈" (181)

34" (864)

19¹⁄₈" (486)

Finished Floor

© 2024 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309

800 BRADLEY (800 272 3539) +1 262 251 6000

bradleycorp.com

Page 5 of 15 2/19/2024 This information is subject to change without notice.

Bradley_Sink_Express_TLX-2

View Latest Version

27" (686)

34" (864)

6⁷⁄₈" (175)

20⁵⁄₈" (524)

17⁵⁄₈" (448)

10⁷⁄₈" (276)

14¾" (376)

7¾" (196)

27" (686)

34" (864)

8⁵⁄₈" (219)

Rim Height Vertical Height Adjustments Fixture Style Notes

34" No Adjustment Standard ADA & TAS At least one basin must meet dimensional requirements and have proper reach, knee, and toe clearance.

31" *Subtract 3" Juvenile ADA & TAS At least one basin must meet dimensional requirements and have proper reach, knee, and toe clearance.

26" *Subtract 8" Junior For use by younger children where ADA guidelines are not a concern.

20⁵⁄₈" (524)

17½" (445)

12⁷⁄₈" (326)

14¾" (376)

7¾" (196)

Side View

Standard Height (ADA) – Verge Faucet Standard Height (ADA) – WBD1

(mm)

© 2024 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309

800 BRADLEY (800 272 3539) +1 262 251 6000

bradleycorp.com

Page 6 of 15 2/19/2024 This information is subject to change without notice.

Bradley_Sink_Express_TLX-2

View Latest Version

24" (610)

31" (787)

6¾" (172)

20⁵⁄₈" (524)

17⁵⁄₈" (448)

10⁷⁄₈" (276)

11¾" (300)

Side View

Juvenile Height (ADA) – Verge Faucet Juvenile Height (ADA) – WBD1

(mm)

24" (610)

31" (787)

8⁵⁄₈" (219)

Rim Height Vertical Height Adjustments Fixture Style Notes

34" No Adjustment Standard ADA & TAS At least one basin must meet dimensional requirements and have proper reach, knee, and toe clearance.

31" *Subtract 3" Juvenile ADA & TAS At least one basin must meet dimensional requirements and have proper reach, knee, and toe clearance.

26" *Subtract 8" Junior For use by younger children where ADA guidelines are not a concern.

20⁵⁄₈" (524)

17½" (445)

12¾" (325)

11¾" (300)

© 2024 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309

800 BRADLEY (800 272 3539) +1 262 251 6000

bradleycorp.com

Page 7 of 15 2/19/2024 This information is subject to change without notice.

Bradley_Sink_Express_TLX-2

View Latest Version

28⁷⁄₈" (735)

33¹⁄₈" (840)

8⁵⁄₈" (219)

20⁵⁄₈" (524)

17½" (445) 12¾" (325)

13⁷⁄₈" (352)

29⁷⁄₈" (760)

33⁷⁄₈" (860)

8⁵⁄₈" (219)

20⁵⁄₈" (524)

17½" (445)

12¾" (325)

14⁵⁄₈" (372)

29⁷⁄₈" (760)

28⁷⁄₈" (735)

33⁷⁄₈" (860)

33¹⁄₈" (840)

6¾" (172)

6¾" (172)

20⁵⁄₈" (524)

20⁵⁄₈" (524)

17⁵⁄₈" (448)

17⁵⁄₈" (448)

10⁷⁄₈" (278)

14⁵⁄₈" (372)

13⁷⁄₈" (352)

7¾" (196)

7¾" (196)

Side View

CSA Height – Verge Faucet

OBC Height – Verge Faucet

CSA Height – WBD1

OBC Height – WBD1

(mm)

© 2024 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309

800 BRADLEY (800 272 3539) +1 262 251 6000

bradleycorp.com

Page 8 of 15 2/19/2024 This information is subject to change without notice.

Bradley_Sink_Express_TLX-2

View Latest Version

Structural Rough-Ins (mm)

Mounting for Standard ADA and TAS height shown.

CODE DESCRIPTION QTY.

A Install (1) ³⁄₈" wall anchor with a minimum pull-out force of 1,000 lb per local codes at locations shown 2

B Install (2) wall anchors per bracket with a minimum pull-out force of 100 lb per local codes at locations shown 2

C Provide structural backing compliant with local building codes. 2

Areas highlighted in gray require sufficient backing compliant with local building codes.

Secure bracket to wall using min. (2) ³⁄₈" anchor bolts to the left of C/L and min. (2) ³⁄₈" anchor bolts to the right of C/L. The (2) anchor bolts to the right of C/L must be min. 16" apart from the anchor bolts to the left of C/L. When mounting is complete, check to ensure the bracket is level.

RIM

HEIGHT

VERTICAL HEIGHT

ADJUSTMENTS

FIXTURE

STYLE

NOTES

34" No Adjustment Standard ADA & TAS At least one basin must meet dimensional requirements and have proper reach, knee, and toe clearance.

31" *Subtract 3" Juvenile ADA & TAS At least one basin must meet dimensional requirements and have proper reach, knee, and toe clearance.

26" *Subtract 8" Junior For use by younger children where ADA guidelines are not a concern.

34" (864)

31¼" (794)

CL

B

A A

B

Finished Floor

36½" (927)

C

31½" (801)12"

(305) 23" (584)

5⁵/₁₆" (135)5³/₁₆" (131)

16" (407)

30½" (775)

¾" (19)

Access Panel Mounting Bracket

© 2024 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309

800 BRADLEY (800 272 3539) +1 262 251 6000

bradleycorp.com

Page 9 of 15 2/19/2024 This information is subject to change without notice.

Bradley_Sink_Express_TLX-2

View Latest Version

Plumbing & Electrical Rough-Ins (mm)

Mounting for Standard ADA and TAS height shown.

VERGE SOAP & FAUCET POWER SUPPLY

1-Station 2-Station 3-Station

Faucet Only AC Adapter x 1 1 duplex outlet req.

AC Adapter x 2 1 duplex outlet req.

AC Splitter* x 1 1 duplex outlet req.

Soap Only AC Adapter x 1 1 duplex outlet req.

AC Adapter x 2 1 duplex outlet req.

AC Splitter* x 1 1 duplex outlet req.

Faucet & Soap AC Adapter x 2 1 duplex outlet req.

AC Splitter* x 1 1 duplex outlet req.

AC Splitter* x 2 1 duplex outlet req.

Soap & Multi-Feed NA NA AC Splitter* x 1 1 duplex outlet req.

Faucet, Soap, & Multi-Feed NA NA AC Splitter* x 2 1 duplex outlet req.

*AC splitter assembly includes one adapter, one 4-way splitter, and four extensions.

Electric outlet locations shown below reflect potential locations.

Refer to the power supply and outlet information below.

CODE DESCRIPTION QTY.

A 1½" NPT Drain, Stub-out 2" from wall 1

H,C ½" Nominal (⁵⁄₈" O.D. Comp.) Hot/Cold supplies, Stub-out 2" from wall 1

E 110V GFI protected electrical outlet (AC faucet and soap only) 2

3" (76)

3" (76)

1½" (38)

6" (152)

16½" (419)

34" (864)

27" (686)

Finished Floor

EE

A

H C

CL

© 2024 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309

800 BRADLEY (800 272 3539) +1 262 251 6000

bradleycorp.com

Page 10 of 15 2/19/2024 This information is subject to change without notice.

Bradley_Sink_Express_TLX-2

View Latest Version

Rough-Ins – Verge Soap & Faucet (mm)

Mounting for Standard ADA and TAS height shown.

CODE DESCRIPTION QTY.

F #10 Anchors for Faucet Control Box Installation Provide sufficient backing behind the mounting locations. 4

6½" (165)

10" (254)

2¹⁄₈" (55)

5⁵⁄₈" (143)

34" (864)

15" (381)

13½" (343)13" (330)

6" (152)1³⁄₁₆" (30) 4¾" (121)

Finished Floor

Mixing Valve Faucet Box

(2x)

FF

FF

CL

© 2024 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309

800 BRADLEY (800 272 3539) +1 262 251 6000

bradleycorp.com

Page 11 of 15 2/19/2024 This information is subject to change without notice.

Bradley_Sink_Express_TLX-2

View Latest Version

Rough-Ins – WBD1 (mm)

Mounting for Standard ADA and TAS height shown.

CODE DESCRIPTION QTY.

G #10 Anchors for Soap Tank Bracket (100 lb pull out force) Provide sufficient backing behind the mounting locations. 12

Combined waste option is not available for use with WBD1 faucet assembly.

6¾" (171)

3¼" (83)

10" (254)

2" (51)

6½" (165)

34" (864)

17³⁄₈" (441)

3½" (89)18⁵⁄₁₆" (466)

16½" (419)

6³⁄₁₆" (156)

5" (127)

5" (127)16¼" (413)5½" (140)

6" (152)5¼" (133)

4¹⁄₈" (105)

Finished Floor

Master Controller (2x)

Mixing Valve

Soap Tank (2x)

G G G G

G

G

G

G

G

G

G

G

CL

© 2024 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309

800 BRADLEY (800 272 3539) +1 262 251 6000

bradleycorp.com

Page 12 of 15 2/19/2024 This information is subject to change without notice.

Bradley_Sink_Express_TLX-2

View Latest Version

Rough-Ins – Verge Individual Top-Fill Soap (mm)

Mounting for Standard ADA and TAS height shown.

CODE DESCRIPTION QTY.

G #10 Anchors for Soap Tank Installation Provide sufficient backing behind the mounting locations. 4

7" (178)

3¹/₈" (80)5½" (140) 18" (457)

10½" (267)

5¹⁄₈" (131)

34" (864)

4½" (114) 6¹⁄₁₆" (155)

Finished Floor

Soap Battery Box (2x)

CL

G GG G

Individual Top-Feed Control Box/Tank

(2x)

© 2024 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309

800 BRADLEY (800 272 3539) +1 262 251 6000

bradleycorp.com

Page 13 of 15 2/19/2024 This information is subject to change without notice.

Bradley_Sink_Express_TLX-2

View Latest Version

Rough-Ins – Verge Multi-Feed Soap (mm)

Mounting for Standard ADA and TAS height shown.

CODE DESCRIPTION QTY.

G #10 Anchors for Soap Tank Installation Provide sufficient backing behind the mounting locations. 4

6⁷⁄₁₆" (164)

5½" (140) 3¹/₈" (80) 7" (178)18" (457)

6⁵⁄₁₆" (161) 15⁹⁄₁₆" (395)

10½" (267)

5¹⁄₈" (131)

34" (864)

4½" (114) 6¹⁄₁₆" (155)

Finished Floor

Multi-Feed Control Box

(2x) Soap Battery Box

(2x)

Use Velcro to attach battery box to front top ledge of tank.

Multi-Feed Tank

G GG G

© 2024 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309

800 BRADLEY (800 272 3539) +1 262 251 6000

bradleycorp.com

Page 14 of 15 2/19/2024 This information is subject to change without notice.

Bradley_Sink_Express_TLX-2

View Latest Version

Models (Must select one)

Model Description

TLX-2 Express Lavatory System TLX-2

Country of Installation (Must select one)

C1 United States or Canada

Standard Selections (Must select one from each category)

Faucet Type (select one)

WBD1 WashBar Duo (available with soap dispenser type WBD1 only) + S53-3100 Verge Faucet – Crestt Series S53-3300 Verge Faucet – Metro Series S53-3500 Verge Faucet – Linea Series S53-3700 Verge Faucet – Zen Series S53-3100-P Verge Faucet – Crestt Series, Includes Trim Plate §

S53-3300-P Verge Faucet – Metro Series, Includes Trim Plate §

S53-3500-P Verge Faucet – Linea Series, Includes Trim Plate §

S53-3700-P Verge Faucet – Zen Series, Includes Trim Plate §

WBD1-DO WashBar Duo Drilling Only 4" Set 4" Centerset (1¼" Drilling Only) 8" Set 8" Centerset (1¼" Drilling Only) SHANK Centershank (1¼" Drilling Only) NFD No Faucet Drilling

Faucet Activation Type (select one)

R Touch-Free Activation NONE No Activation

Water Supply Type (select one)

T Thermostatic Mixing Assembly (supply hoses and shut-offs included) L Single Tempered Line Assembly (supply hoses and shut-offs included)

Flow Control Type‡ (select one)

3 0.35 gpm (1.30 Lpm) Silicone Tip, Multiple Individual Laminar Flow Streams 5 0.50 gpm (1.90 Lpm) Silicone Tip, Multiple Individual Laminar Flow Streams

Faucet Finish Type‡ (select one)

PC Polished Chrome

BB Brushed Black Stainless

BS Brushed Stainless

BZ Brushed Bronze

BR Brushed Brass

BN Brushed Nickel

Faucet Power Supply (select one)

AC AC Power** BA Battery – 4x AA alkaline batteries included per faucet NONE No Power Supply

Soap Dispenser Type (select one)

WBD1 WashBar Duo (available with faucet type WBD1 only) + 6-3100 Verge Deck-Mounted Soap Dispenser – Crestt Series 6-3300 Verge Deck-Mounted Soap Dispenser – Metro Series 6-3500 Verge Deck-Mounted Soap Dispenser – Linea Series 6-3700 Verge Deck-Mounted Soap Dispenser – Zen Series WBD1-DO WashBar Duo Drilling Only SDO 1-3/8" Soap Drilling Only NSD No Soap Dispenser/No Drilling

Soap Activation Type (select one)

R Touch-Free Activation NONE No Activation

Soap Type^ (select one)

F Foam Soap L Liquid Soap

Soap Fill System (select one)

T Single (top fill at spout) M Multi-Feed (shared tank, includes 6-SOAP-MFT Multi-Feed Soap

Tank Assembly)

Soap Dispenser Finish Type (select one)

PC Polished Chrome

BB Brushed Black Stainless

BS Brushed Stainless

BZ Brushed Bronze

BR Brushed Brass

BN Brushed Nickel

Soap Power Supply (select one)

AC AC Power** BA Battery – 4x D-cell batteries included per dispenser NONE No Power Supply

** AC power supply will include either individual AC plug-in adapter or 4-way AC splitter assembly depending on configuration.

Available with Verge faucet selection only.

Available with faucet drilling only.

Available with Verge soap dispenser selection only.

Available with soap drilling only.

† This color contains large, randomly distributed chips.

‡ Available with Verge faucet or WBD1 selection only.

^ Available with Verge soap or WBD1 selection only.

+ Combined Waste not available with WBD1.

§ Trim plate finish will match Faucet Finish for PC, BB & BS. All other faucet finishes will receive a PC trim plate.

https://www.bradleycorp.com/mediamanager/view/26592/Bradley_Sink_Express_TLX-2.pdf https://www.bradleycorp.com/mediamanager/view/26592/Bradley_Sink_Express_TLX-2.pdf https://www.bradleycorp.com/mediamanager/view/25260 https://www.bradleycorp.com/mediamanager/view/25678 https://www.bradleycorp.com/mediamanager/view/25680 https://www.bradleycorp.com/mediamanager/view/25679 https://www.bradleycorp.com/mediamanager/view/25681 https://www.bradleycorp.com/mediamanager/view/25260 https://www.bradleycorp.com/mediamanager/view/25685 https://www.bradleycorp.com/mediamanager/view/25683 https://www.bradleycorp.com/mediamanager/view/25684 https://www.bradleycorp.com/mediamanager/view/25682 https://www.bradleycorp.com/mediamanager/view/25872

© 2024 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309

800 BRADLEY (800 272 3539) +1 262 251 6000

bradleycorp.com

Page 15 of 15 2/19/2024 This information is subject to change without notice.

Bradley_Sink_Express_TLX-2

View Latest Version

Standard Selections (Must select one from each category)

Color of Terreon Deck (select one)

NOTE: Click on any swatch to view as a larger image.

Standard Colors

ALP-WHITE Alpine White PEBBLE Pebble Beach

DRIFT Driftwood † PEP-WHT Peppered White

DS-WHT Designer White POLAR Polar Ice †

E-GRAY Empire Gray RIVER Riverstone

GLACIER Glacier SAND Sandtrap

GRAPH Graphite S-CREEK Stone Creek

LANNON LannonStone S-MIST Silver Mist

MOONSTONE Moonstone † WHT-SAND White Sand

Access Panel Type (select one)

COAL Coal

Waste Assembly Type (select one)

CHROME Chrome-Plated Waste Assembly (1 P-Trap/1 drain connection) POLY Polypropylene Waste Assembly (1 P-Trap/1 drain connection) NONE Waste Assembly by Others

** AC power supply will include either individual AC plug-in adapter or 4-way AC splitter assembly depending on configuration.

Available with Verge faucet selection only.

Available with faucet drilling only.

Available with Verge soap dispenser selection only.

Available with soap drilling only.

† This color contains large, randomly distributed chips.

‡ Available with Verge faucet or WBD1 selection only.

^ Available with Verge soap or WBD1 selection only.

+ Combined Waste not available with WBD1.

§ Trim plate finish will match Faucet Finish for PC, BB & BS. All other faucet finishes will receive a PC trim plate.

https://www.bradleycorp.com/mediamanager/view/26592/Bradley_Sink_Express_TLX-2.pdf https://www.bradleycorp.com/mediamanager/view/26592/Bradley_Sink_Express_TLX-2.pdf https://www.bradleycorp.com/mediamanager/view/3163/Peppered%20White https://www.bradleycorp.com/mediamanager/view/4768/Stone_Creek https://www.bradleycorp.com/mediamanager/view/3194/White_Sand https://www.bradleycorp.com/mediamanager/view/4771/Pebble_Beach https://www.bradleycorp.com/mediamanager/view/29043/Polar-ice https://www.bradleycorp.com/mediamanager/view/3164/Sand_Trap https://www.bradleycorp.com/mediamanager/view/4764/Silver_Mist https://www.bradleycorp.com/data/wp-content/uploads/2018/08/Alpine-White_Terreon.jpg https://www.bradleycorp.com/mediamanager/view/3182/Lannonstone https://www.bradleycorp.com/mediamanager/view/4769/Moonstone https://www.bradleycorp.com/mediamanager/view/4763/Driftwood https://www.bradleycorp.com/data/wp-content/uploads/2018/08/Designer-White_Terreon.jpg https://www.bradleycorp.com/mediamanager/view/3177/Empire_Gray https://www.bradleycorp.com/mediamanager/view/3179/Graphite https://www.bradleycorp.com/mediamanager/view/29034/Glacier https://www.bradleycorp.com/mediamanager/view/3165/Riverstone

S53-3500 Verge™ Faucet – Linea Series

© 2024 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309

800 BRADLEY (800 272 3539) +1 262 251 6000

bradleycorp.com

Verify all rough-in dimensions prior to installation.

Consult local and national codes. Conformity and compliance to local and national codes is the responsibility of the installer.

Page 1 of 4 2/19/2024 This information is subject to change without notice.

Bradley_Faucets_Linea_S53-3500

View Latest Version

Linea Series Features - Faucet and Soap x Sleek lines and curved-edged design pairs with Verge™ soap model 6-3500 x Matching faucet and soap designs that integrate seamlessly with Bradley lavatories** x Chrome-plated cast brass construction with optional in-stock PVD finishes* x Sensing optimized to eliminate false activations and maximize battery life x Vandal-resistant construction includes concealed sensor package, durable PVD finish options, and rotation-resistant locking nut x Patents Pending

Faucet Key Features x Touch-free dual-sensor activation x Multiple low flow laminar options x Spout reach designed to optimize handwashing space x Battery standard or optional AC plug-in adapter with battery backup x Centershank, rotation-resistant locking nut x Low battery LED indicator with sensor package x Consistent parts platform across all Verge faucet designs x Cast brass spout construction with durable, environmentally-friendly finishes* x Optional trim plate with integral rotation-resistant pins are available for additional vandal resistance

Specification Sleek lines and curved-edged design pairs with soap model 6-3500 and integrates seamlessly with Bradley lavatories**. Touch-free, dual-sensor activation with time of flight and diffuse reflective sensors that work in tandem to detect and confirm the user's presence, eliminating false activations. Battery pack standard or optional AC adapter with battery back-up. Faucet shall feature chrome-plated cast brass construction with optional in-stock PVD finish. Low-flow laminar device options available to conserve water. Vandal-resistant construction includes concealed sensor package, vandal-resistant laminar flow device, durable PVD finish options, and rotation-resistant locking nut.

Overall Dimensions x Height: 5-1/2" (140 mm) x Reach: 4-11/16" (119 mm) to flow device x Reach: 5-5/8" (142 mm) to sensor centerline

Compatible Bradley Products x Verge Deck-Mounted Soap Dispenser – Linea Series x Verge Lavatory Systems** x ELX Lavatory Systems** x LD-3010 OmniDecks**

Complies with x ADA x ICC/ANSI 117.1

Product Compliance

Listed by IAPMO R&T to x Uniform Plumbing Code (UPC) x National Plumbing Code of Canada x International Plumbing Code (IPC) x ASME A112.18.1/CSA B125.1 x NSF/ANSI/CAN 61

Listed by NSF International to x NSF/ANSI 372

Certified to

NSF/ANSI 372

Finishes Polished Chrome

Brushed Black Stainless*

Brushed Stainless*

Brushed Bronze*

Brushed Brass*

Brushed Nickel*

*PVD Finishes, see PVD Finishes section on Page 2.

Serves the American Disabilities Act and ICC/ANSI 117.1 guidelines, citations 309.4, 606.4 when installed according to these requirements.

Consult local codes and standards.

https://www.bradleycorp.com/mediamanager/view/25679 https://www.bradleycorp.com/product/verge-soap-dispenser-linea-series https://www.bradleycorp.com/product-category/verge https://www.bradleycorp.com/product-category/express https://www.bradleycorp.com/product-category/omnideck

© 2024 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309

800 BRADLEY (800 272 3539) +1 262 251 6000

bradleycorp.com

Verify all rough-in dimensions prior to installation.

Consult local and national codes. Conformity and compliance to local and national codes is the responsibility of the installer.

Page 2 of 4 2/19/2024 This information is subject to change without notice.

Bradley_Faucets_Linea_S53-3500

View Latest Version

Operation x Touch-free dual sensor activation x Standard 11 second max run time per activation x Standard 11 second auto system rinse if not activated within 24 hours x Option for manual flush x Low flow options 0.35 gpm (1.3 Lpm), 0.05 gpc (0.25 Lpc) or 0.50 gpm (1.9 Lpm), 0.09 gpc (0.35 Lpc) x Laminar flow device

Sensor x Dual sensor detects user’s hand within a 4-9/16" (116 mm) detection range x First sensor is always operating but does so under low power settings, while the second sensor is more accurate in its detection, minimizing false activations x After the first sensor detects the presence of something, the second sensor is activated to ensure accurate activation of the fixture x Sensors work in tandem to adapt to light, color, and optimize battery life x Sensor has a narrow cone to prevent simultaneous activations with the soap dispenser

Indicator Lights x Power ON: Flashes red for 1.5 seconds x Water dispense activation: Single flash green light x Low power indication: Continuously flashing green light

Power Source Standard Equipment x Battery box x 4x AA alkaline batteries included x Battery life – alkaline up to 500,000 cycles per set x Easily convert from battery only to AC adapter x Low battery indicator with sensor package

Optional Equipment x Single AC adapter or AC adapter splitter kit (ordered separately) x Splitter kit powers up to 4 faucets or combination of 4 faucets and soap dispensers x 120V AC/6V DC plug-in adapter requires 120V/220V, 50/60Hz power source x Battery box converts to battery back-up when using AC adapter

Mounting x Requires 1-1/4" to 1-3/8" centershank drilling x When paired with Bradley lavatory, faucet drilling will be 1¼".

x Requires a maximum deck thickness of 2".

x Faucet comes with rotation-resistant connection x Minimum of 6" center-to-center spacing between Verge faucet and Verge soap drillings is required to ensure proper fitup of components

Materials Faucet comes in chrome-plated cast brass construction with optional in-stock PVD finishes*.

* PVD Finishes Physical Vapor Deposition is an intricate, environmentally friendly finishing process that molecularly bonds the finish to the faucet, creating a very hard, durable surface that will not corrode, discolor, or tarnish.

Vandal Resistance x Concealed sensor package deters vandalism x Shank features rotation-resistant locking nut x Vandal-resistant laminar flow device x Durable PVD finish is scratch resistant x Optional 4" centerset trim plates with integral rotation-resistant pins are available for additional vandal resistance

Water Supply x Operating water pressure range 20-125 psi x Control module integrates choice of thermostatic mixing valve or tempered line valve to deliver tempered water x Water source located outside of control module to prevent water damage to electrical components x In-line filter included with mixing valve and tempered line valve to trap debris

Drain Assembly x Complete your faucet selection with an optional drain assembly x Includes grid strainer in matching chrome-plated finish or PVD finishes x Available in a straight or ADA offset configuration

Lithium AA…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .