This document outlines the salient characteristics for two total stations and related surveying accessories required by the US Geological Survey South Atlantic Water Science Center in Norcross, Georgia. The equipment must meet specified accuracy, measurement, display, and operating requirements. The total stations should have a range of 1.5m to 300m with a 5cm x 5cm reflector and 1.5m to 5000m with a single prism. Additional requirements include Bluetooth capability, 512MB RAM with 4GB flash memory, angle measurement accuracy of 1" horizontal and 0.3mgon vertical, operating temperature range of -20C to 50C, and Windows Embedded Compact 7 operating system. The solicitation also specifies requirements for tripods, prism poles, prism assemblies, prism systems, and accessories that must be met. The related federal contract opportunity is solicitation number 140G0123Q0232 for a Trimble C5 1" total station or equal, issued by the Department of Interior US Geological Survey Office of Acquisitions and Grants.

View the file

Other files

File Type Posted
Sol_140G0123Q0232.pdf PDF
B08_ATCH_2_508_S23126_508.pdf PDF
B08_ATCH_3_FISMA_S23126_OAG_12_14_22.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Salient Characteristics

The USGS South Atlantic Water Science Center in Norcross, GA needs to purchase two Total Stations and related accessories. This equipment will be used for surveying gage datums for streamgages and wells, sensors deployed during hurricanes, and indirect flow measurements. It is imperative that the accuracy level of the surveying equipment meet or exceed the requirements below.

1” TOTAL STATION & RELATED ACCESSORIES

SALIENT CHARACTERISTICS:

2 EACH UNITS SHALL INCLUDE:

1 EA, Total Station:

1. Shall have an Ingress Protection (IP) rating of at least IP66.

2. Shall have 1.5 m to at least 300 m range with 5 cm x 5 cm reflector sheet.

3. Shall have 1.5 m to at least 5000 m range with single prism 6.25 cm.

4. Shall have autofocus feature to enable precise and fast focus.

5. Shall have reflectorless range to at least 800 m.

6. Shall have an accuracy of at least +/-(2+2 ppm x D) mm in standard measurement mode using a prism.

7. Shall have 512 MB RAM, 4 GB flash memory or better.

8. Shall have at least one (1) RS232C serial port and two (2) USB ports.

9. Shall be Bluetooth capable.

10. Shall have optical plummet with 3 x magnification, 5 degree field view, and minimum 0.5 m focusing distance or better.

11. Shall have a dual axis tilt sensor that uses the liquid-electric detection method with at least +/- 3’ compensation range.

12. Shall include software.

a. Shall consist of field applications software to support workflows with the Total Station.

b. Shall be optimized for measuring points, stake-out points, lines, arcs, alignments, and scanning.

c. Shall provide graphical routines for calculating points and features.

d. Shall be capable of providing a continuous display of maps or video and forms in a “side-by-side” manner.

e. Shall support coordinate geometry routines.

f. Shall allow user to collect, share, and deliver data and information in the field.

g. Shall include onboard software.

13. Shall have measuring intervals in tracking mode of at least 0.3 s and standard normal mode of at least 1.0 s for both prism and reflectorless mode.

14. Shall have angle measurement at ISO 17123-3 with accuracy at least 1” horizontal and at least 0.3 mgon vertical.

15. Shall have absolute encoder reading system.

16. Shall have angle measurement circle diameter of at least 62 mm.

17. Shall have diametrical/single for horizontal/vertical angle. Shall have diametrical for the horizontal angle measurement and single for the vertical angle measurement

18. Shall have telescope with tube length of at least 125 mm, erect image 30 x magnification, effective diameter of objective at 45 mm, EDM diameter at 50 mm, Field of view at 1°25’, Resolving power at 3”, minimum focusing distance no less than 1.5 m, and Coaxial Red Light Laser Pointer.

19. Shall have a tracklight.

20. Shall have 4 step reticle illumination.

21. Shall have level vials with sensitivity of circular level vial at 10’/2 mm.

22. Shall have optical plummet with erect image, 3x magnification, 5° field of view, and : 0.5 m minimum focusing range.

Salient Characteristics

23. Shall have a face 1 and face 2 display that is LCD back-lit with 640 x 480 pixel resolution.

24. Shall have tangent clamps.

25. Shall have Dual Core 800 MHz or equivalent.

26. Shall be no larger than 206 mm x 169 mm x 318 mm.

27. Shall weigh no more than 4.3 kg without batteries.

28. Shall have operating temperature range of -20 C to 50 C

29. Shall have a Windows Embedded Compact 7 operating system.

2 EA, Tripod:

30. Shall have round/flat head and standard 5/8” x 11” threaded stud for mounting instruments.

31. Shall have wood legs with hand hole for carrying.

32. Shall have shoulder strap.

33. Shall have Twist-Locks.

34. Shall extend to at least 72 inches (1.83 m).

35. Shall collapse to at least 46.5 inches (1.18 m).

36. Shall be orange for visibility

2 EA, Prism Pole:

37. Shall be a one-section pole.

38. Shall have soft rubber knob.

39. Shall have TLV lock with 40-minute vial built into the lock.

40. Shall have dual graduations at 0.01 ft/cm.

41. Shall have adjustable tip.

42. Shall be powder-coated and aluminum.

43. Shall be red and white.

44. Shall extend to at least 8.53 ft (2.60 m) and collapse to at least 4.97 ft (1.516 m).

45. Shall weigh no more than 3.30 lb (1.50 kg).

2 EA, Prism Assembly:

46. Shall have 62 mm, 2 sec, prism that is silver-coated with 5.5 x 7 inch target.

47. Shall be fluorescent yellow and black.

2 EA, Prism System:

48. Shall have 25 mm copper-coated prism, for fog prevention.

49. Shall include a tilting holder, with friction axis, zero or -30 mm offset

50. Shall be powder painted fluorescent orange with fluorescent yellow targets.

51. Shall include a 40-min adjustable circular side-mounted vial.

52. Shall allow for mounting on a Prism pole or tribrach at three heights: 70 mm, 100 mm, 115 mm.

53. Shall be able to use as a hand-held using the plumb bob bracket or with S-hook for quick attachment to plumb bob.

54. Shall include a point for stake-out work and a system bag with belt loop

55. Shall weigh no more than 0.34 lb (0.15 kg).