This document is a submittal register for a solicitation to replace the water system at Diablo East for the National Park Service Intermountain Region. The solicitation requires various submittals related to construction plans, materials, and testing for cast in place concrete, asphalt paving, earthwork, water distribution piping, hydrants, valves, and pipe fittings. Key submittals include reinforced bar and concrete mix designs, alkali silica reaction testing, curing and sealing compounds, compaction testing, and leakage and disinfection testing. The submittal register lists over forty individual submittal items grouped under relevant specification sections, and indicates whether each submittal is informational, a sample, calculation, test report, shop drawing, or manufacturing data.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| B09 40527268 AM01 RFP Att1 Revised Specs_0001.pdf | ||
| B09 40527268 AM01 RFP Att5 Revised Price Schedule_0001.xlsx | XLSX spreadsheet | |
| B09 40527268 AM01 RFP Att3 Revised Drawings_0001.pdf | ||
| B09 40527268 AM01 RFP Att10 RFP QA_0001.docx | DOCX document | |
| Sol_140P1321R0008_Amd_0001.pdf | ||
| B08 40527268 RFP Att5 Price Schedule.xlsx | XLSX spreadsheet | |
| B08 40527268 RFP Att6 Project Experience Questionnaire.docx | DOCX document | |
| B08 40527268 RFP Att4 WD TX20210090 1Jan2021.pdf | ||
| B08 40527268 RFP Att3 Drawings.pdf | ||
| B08 40527268 RFP Att1 Specs.pdf | ||
| B08 40527268 RFP Att9 Subcontracting Percentage Worksheet.xlsx | XLSX spreadsheet | |
| Sol_140P1321R0008.pdf | ||
| B08 40527268 RFP Att8 General References.doc | DOC document | |
| B08 40527268 RFP Att7 Past Performance Questionnaire.docx | DOCX document |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C
ER
T.
/L
A B
T
ES
T
R
EP
O R
T/ C
A
LC
O R
P
LA
N
M fg
. D A
TA
IN
ST
R
U C
TI
O
N S
SH
O
P D
R A
W
IN
G
SA
M
P
LE
M fg
. D A
TA
IN
ST
R
U C
TI
O
N S
TR
A
N
SM
IT
TA
L
N U
M B
ER
SU
B
M
IS
SI
O
N D
A
TE
ST
A
TU
S
13100 1.3.A.1 Letter designating Project Superintendent X 13100 1.3.A.2 Construction Schedule X 13100 1.3.A.3 Schedule of Values X 13100 1.3.A.4 Accident Prevention Plan X 13100 1.3.A.5 List of Subcontractors X
13100 1.3.A.6 Statement of Compliance of Labor Laws from Subcontractors X
13100 1.3.A.7 Evidence of liability insurance coverage and workman’s compensation for the Contactor and all subcontractors X
13100 1.3.A.8 Waste Management Plan X 13100 1.3.A.9 Quality Control Plan X 13100 1.3.A.19 Stormwater Pollution Prevention Plan X
015000 3.2.A Temporary Facilities Plan X
033000 2.3 Reinforcing Bars X
033000 2.4 Concrete Mix Design X
033000 2.7.A.8 Alkali Silica Reaction Test - Sand X
033000 2.7.A.8 Alkali Silica Reaction Test - Gravel X
033000 3.8.C.4 Curing and Sealing Compound X
033000 3.10.A Concrete Field Quality Control Tests X
321216 2.4.A Hot-Mix Asphalt Mix Design X
221113 2.1.A.1 HDPE Pipe 4-Inches and Larger X
221113 2.1.A.3 HDPE Pipe Fittings 4-Inches and Larger X
221113 2.1.A.2 HDPE Pipe smaller than 4-Inches X
221113 2.1.A.3 HDPE Pipe Fittings smaller than 4-Inches X
221113 3.14.A Warning Tape X
221113 2.1.A.4 2-inch and smaller HDPE to Threaded Transition Fitting X
221113 2.1.B Restraint Devices for AWWA fittings, valves X
221113 2.3.C HDPE Pipe Wrap X
221113 2.3.D Fusion End HDPE Transition Fittings X
221113 2.2 HDPE Pipe Encasement X
221113 2.3.A 8" Gate Valve X
221113 2.3.A 6" Gate Valve X
221113 2.3.A 4" Gate Valve X
221113 2.4.A Tapping Sleeve Assembly X
221113 2.4.B Valve Box X
221113 2.5.A Corporation Valve X
221113 2.5.B Curb Stop X
221113 2.5.C Curb Stop Box with Stationary Rod X
221113 2.6.A Backflow Preventer Valve (RPZ) X
221113 2.7.A Backflow Preventer Valve (RPZ) Enclosure X
221113 2.8.A Combination Air Release Valve X
221113 2.9.A Air Release Valve Box X
221113 2.11.A Dry-Barrel Fire Hydrant X
221113 2.11.B Post-Type Fire Hydrant X
221113 2.13.A Internet Conduit X
221113 2.13 Internet Conduit Warning Tape X
221113 2.13.B Conduit Access Box X
221113 2.14.A Tracer Wire X
221113 2.14.B Tracer Wire Access Box X
221113 2.14.C Tracer Wire Splices X
312333 2.1.D Base Course X X
312333 2.1.F Bedding Course X X
312333 2.1.G Drainage Course X X
312333 1.4.B.1-2 ASTM 2487 Soil Classifications and Compaction Curves X
312333 3.21.A Compaction Testing Firm X
331300 3.19 Leakage Test Results X
331300 3.21 Disinfection Test Results X
NOTE: This submittal list is not all-inclusive. Contractor to ensure submittal requirements of contract are met in accordance with the specifications
LIST OF MATERIAL SUBMITTALS
Spec.
Sec.
REQUIREMENTS
(indicate with an "X")
SUBMITTAL
Par. No.
AMIS 269091
EARTHWORK FOR TRENCHES AND STRUCTURES
DISINFECTION OF WATER SYTEM
OTHER
HYDRANTS
VALVES
PIPE
FACILITY WATER DISTRIBUTION PIPING
CAST IN PLACE CONCRETE
FITTINGS
STATUS
ACTION
Description
DIVISION 1
INFORMATIONAL
ASPHALT PAVING