B01 RFP ATTACHMENT J02C as build Kyle_Health Center Addition.pdf
PDF 9 MB Posted
- Attached to
- Kyle Health Center Generator Replacement Federal contract opportunity
- Solicitation number
- 75H70123R00023
About this file
This solicitation is for replacement of the generator at the Kyle Health Center in South Dakota. The Indian Health Service is seeking proposals to remove the existing generator and install a new 150 kW diesel generator with associated automatic transfer switch and distribution panel. Bids are due by July 15th, 2023, with award anticipated by August 15th. Pricing shall remain valid for 90 days. The contract type will be firm-fixed price. This opportunity is set aside for small businesses, with preference given to Native American-owned firms.
View the file
Other files for this federal contract opportunity
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VICINITY MAP
PROJECT LOCATION
PLAN NORTH
TITLE/DISCIPLINE NAME/CONTACT COMPANY PHONE EMAIL
PROJECT MANAGER ALEX WEIERS TSP, Inc. 605.343.6102 weiersar@teamtsp.com
PROJECT ARCHITECT DAN JOHNSON TSP, Inc. 402.493.8997 johnsondp@teamtsp.com
CIVIL ENGINEER TODD SCHULTZ TSP, Inc. 605.343.6102 schultztm@teamtsp.com
STRUCTURAL ENGINEER ALEX WEIERS TSP, Inc. 605.343.6102 weiersar@teamtsp.com
MECHANICAL ENGINEER STEVEN TEBBEN TSP, Inc. 605.343.6102 tebbensm@teamtsp.com
ELECTRICAL ENGINEER DARREL BREN TSP, Inc. 605.336.1160 brendl@teamtsp.com
DESIGN TEAM
INDEX TO DRAWINGS
MOST COMMONLY USED ABBREVIATIONS
D DEPTH
DBL DOUBLE
DEMO DEMOLITION, DEMOLISH
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DFPT DRYFALL PAINT
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DIV DIVIDE, DIVISION
DISP DISPENSER
DN DOWN
DR DOOR
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING (S)
DWR DRAWER
DWTR DUMBWAITER
(E) EXISTING
E EAST
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
ENL ENLARGED
EMER EMERGENCY
ENGR ENGINEER
EOP EDGE OF PAVEMENT
EPDM ETHYLENE PROPYLENE DIENE
MONOMER
EPS EXPANDED POLYSTYRENE BOARD
EPT EPOXY PAINT
EQ EQUAL
EQUIP EQUIPMENT
ES EACH SIDE
EST ESTIMATE
ETC ETCETERA
ETR EXISTING TO REMAIN
EW EACH WAY
EXIST EXISTING
EXC EXCAVATE/EXCAVATION
EXH EXHAUST
EXP EXPANSION/EXPOSED
EXT EXTERIOR
EWC ELECTRIC WATER COOLER
FA FIRE ALARM
FAB FABRICATE/FABRICATION
FD FLOOR DRAIN
FDC FIRE DEPRATMENT CONNECTION
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISHED FLOOR
FFE FINISH FLOOR ELEVATION
FIN FINISH (ED)
FLOUR FLOURESCENT
FLR FLOOR (ING)
FO FACE OF
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FOS FACE OF STUD
FOF FACE OF FINISH
FR FIRE RESISTANT/FRAME
FRP FIBERGLASS REINFORCED PANEL
FS FLOOR SINK
FT FOOT, FEET/FIRE TREATED
FTG FOOTING
ABBREVIATIONS:
AB ANCHOR BOLT/ROD
ABV ABOVE
AC ASPHALTIC CONCRETE/AIR
CONDITIONER
ACC ACCESSIBLE
ACM ALUMINUM COMPOSITE MATERIAL
ACOUS ACOUSTICAL
ADD ADDENDUM
ADH ADHESIVE
ADJ ADJUSTABLE, ADJACENT, ADJOINING
AFF ABOVE FINISH FLOOR
AFG ABOVE FINISH GRADE
ALT ALTERNATE
ALUM ALUMINUM
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATE
ARCH ARCHITECT (URAL)
ASI ARCHITECTURAL SUPPLEMENTAL
INFORMATION
BD BOARD
BEV BEVELED
BFF BELOW FINISH FLOOR
BL BRICK LEDGE
BLDG BUILDING
BLKG BLOCK (ING)
BM BEAM
BOT BOTTOM
BO BOTTOM OF
BOC BOTTOM OF CONCRETE
BOF BOTTOM OF FOOTING
BRG BEARING
BRK BRICK
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C CHANNEL/CELSIUS
CAB CABINET
CB CERAMIC BASE
CD CONSTRUCTION DOCUMENTS
CEM CEMENT
CF CUBIC FEET OR FOOT
CG CORNER GUARD
CIPC CAST-IN-PLACE CONCRETE
CJ CONTROL/CONSTRUCTION JOINT
CL CENTER LINE
CLG CEILING
CLKG CAULKING
CLR CLEAR, CLEARANCE
CMU CONCRETE MASONRY UNIT
CO CHANGE ORDER/CLEAN OUT
COL COLUMN
COMB COMBIMATION
COMP COMPOSITE/COMPOSITION
CONC CONCRETE
CONN CONNECT (ION)
CONST CONSTRUCTION
CONT CONTINUOUS, CONTINUE
CONTR CONTRACT (OR)
COORD COORDINATE
CORR CORRUGATED/CORRIDOR
CPT CARPET
CPPT CARPET TILE
CSMT CASEMENT
CT CERAMIC TILE
CTB CARPET TILE BASE
CTR CENTER
FURR FURRING
FUT FUTURE
GA GAGE, GAUGE
GB GRAB BAR
GC GENERAL CONTRACTOR
GALV GALVANIZED
GC GENERAL CONTRACTOR
GI GALVANIZED IRON
GL GLASS
GLU LAM GLUE LAMINATED (BEAM)
GWB GYPPSUM WALL BOARD
GYP GYPSUM
HB HOSE BIB
HC HANDICAP / HOLLOW CORE
HD HEAVY DUTY
HDBD HARDBOARD
HDR HEADER
HDWD HARDWOOD
HDWR HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HVAC HEATING, VENTILATION, AIR-
CONDITIONING
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER/DIMENISON
IN INCH(ES)
INCL INCLUDE (D), INCLUDING
INFO INFORMATION
INSP INSPECTION
INSTR INSTRUCTION(S)
INSUL INSULATE (D), INSULATION
INT INTERIOR
JAN JANITOR
JST JOIST
JT JOINT
KCJ KEYED CONSTRUCTION JOINT
KO KNOCK OUT
L LENGTH / ANGLE
LAB LABORATORY
LAM LAMINATE (ED)
LAV LAVATORY
LB POUND
LF LINEAR FEET
LH LEFT HAND
LKR LOCKER
LOC LOCATION
LONG LONGITUDINAL
LT LIGHT
LVR LOUVER
LVT LUXURY VINYL TILE
MBC MINNESOTA BUILDING CODE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MC MEDICINE CABINET
MECH MECHANICAL
MEMB MEMBRANE
MEZZ MEZZANINE
MFR MANUFACTURE (R)
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
S SOUTH
SB SPLASH BLOCK
SC SOLID CORE
SCHED SCHEDULE
SCR SHOWER CURTAIN ROD
SCT SECTION
SD SOAP DISPENSER
SF SQUARE FOOT
SHT SHEET
SHTHG SHEATHING
SIM SIMILAR
SLDG SLIDING
SLNT SEALANT
SND SANITARY NAPKIN DISPENSER
SNDU SANITARY NAPKIN DISPOSAL UNIT
SOG SLAB ON GRADE
SPEC SPECIFICATION (S)
SQ SQUARE
SSM SOLID SURFACE MATERIAL
SST STAINLESS STEEL
ST STREET
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
SV SHEET VINYL
SW SHEARWALL
SYM SYMMETRICAL
T TREAD
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TB TOWEL BAR
TBD TO BE DETERMINED
TEMP TEMPORARY/TEMPERED
TER TERRAZZO
THD THREAD (ED) (S)
THK THICKNESS
THRU THROUGH
TKBD TACKBOARD
TL TILE
TO TOP OF
TOB TOP OF BEAM
TOC TOP OF CONCRETE/CURB
TOD TOP OF DECK
TOF TOP OF FOOTING (FOUNDATION)
TOP TOP OF PIER
TOJ TOP OF JOIST
TOS TOP OF SLAB/STEEL
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPO THERMOPLATIC POLYOLEFIN
TPTN TOILET PARTITION
TRANS TRANSVERSE
TS TUBE STEEL
TYP TYPICAL
UG UNDERGROUND
UH UNIT HEATER
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
V SHEAR
VAR VARIES
VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VIF VARIFY IN FIELD
VR VAPOR RETARDER
VWC VINYL WALL COVERING
W WEST/WIDTH
W/ WITH
W/O WITHOUT
WA WEDGE ANCHOR
WB WOOD BASE
WC WATER CLOSET
WD WOOD/WOODWORK
WDW WINDOW
WF (W) WIDE FLANGE
WG WALL GUARD
WH WATER HEATER
WI WROUGHT IRON
WL WIND LOAD
WP WATERPROOF (ING)
WR WATER RESISTANT
WSCT WAINSCOT
WT WEIGHT/WINDOW TREATMENT
WWF WELDED WIRE FABRIC
SYMBOLS USED AS ABBREVIATIONS:
& AND
L ANGLE
LL DOUBLE ANGLE
@ AT
d PENNEY
# POUND OR NUMBER
Ø ROUND OR DIAMETER
MR MIRROR
MTL METAL
(N) NEW
N NORTH
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED / CONTRACTOR
INSTALLED
OFOI OWNER FURNISHED / OWNER
INSTALLED
OH OVERHEAD
OPP OPPOSITE
OPG OPENING
ORIG ORIGINAL
ORD OVERFLOW ROOF DRAIN
OZ OUNCE
PAR PARALLEL
PCF POUNDS PER CUBIC FOOT
PED PEDESTAL
PERF PERFORATED
PERP PERPENDICULAR
PL PLATE
PLAM PLASTIC LAMINATE
PLYWD PLYWOOD
PNL PANEL
PR PAIR/PROPOSAL REQUEST
PRCST PRECAST CONCRETE
PREFAB PREFABRICATE
PSI POUNDS PER SQUARE INCH
PSF POUNDS PER SQUARE FOOT
PT PAINT / PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTN PARTITION
PTR PAPER TOWEL RECEPTACLE
PVC POLYVINYL CHLORIDE
QT QUARRY TILE
R RADIUS/RISER
RB RUBBER BASE
RBR RUBBER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REBAR REINFORCING BAR
REC RECESSED
REF REFERENCE/REFRIGERATOR
REINF REINFORCE (D), (ING), (MENT)
REQ REQUIRE
REQD REQUIRED
RES RESILIANT FLOORING
RET RETURN
REV REVISION (S), REVISED
RFI REQUEST FOR INFORMATION
RFP REQUEST FOR PROPOSAL
RH RIGHT HAND
RL RIDGE LINE
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
RVS REVERSE (SIDE)
RWL RAIN WATER LEADER
EARTH / RECOMPACT SOIL
ENGINEERED FILL
GANULAR FILL / DRAINAGE
COURSE
STONE / GRAVEL
CONCRETE
NATIVE UNDISTURBED SOIL
BRICK
CONCRETE MASONRY UNIT
METAL/STEEL
RIGID INSULATION
GROUT
WOOD WALL / FINISH
MORTAR
PLYWOOD / OSB / PARTICLE
BOARD
WOOD-GLUED / LAMINATED
WOOD - BLOCKING OR SHIM
WOOD - CONTINUOUS
FRAMING
BATT OR BLANKET
INSULATION/FIRE SAFING
EXISTING AREAS / ELEMENTS
MATERIAL LEGEND
A - 5 0 1
A N N NA
SHEET SEQUENCE
NUMBER 01-99
SHEET TYPE
DESIGNATOR
DISCIPLINE
CHARACTER
MODIFIER
CHARACTER
SHEET TYPE DESIGNATORS
0 GENERAL (SYMBOLS LEGEND, NOTES, ETC)
1 PLANS (HORIZONTAL VIEWS)
2 ELEVATIONS (VERTICAL VIEWS)
3 SECTIONS (SECTIONAL VIEWS)
4 LARGE SCALE VIEWS
5 DETAILS
6 SCHEDULES AND DIAGRAMS
7 USER DEFINED
8 USER DEFINED
9 3D REPRESENTATIONS (ISO, PERSP, PHOTOS)
1 2 3 4 5 6
E2 E3 E4
C5
A4A1
A
B
C
D
E
TS
P
A
B
C
D
E
1 2 3 4 5 6
DISCIPLINE CHARACTERS
G GENERAL
H HAZARDOUS
C CIVIL
L LANDSCAPE
S STRUCTURAL
A ARCHITECTURAL
I INTERIOR
P PLUMBING
M MECHANICAL
E ELECTRICAL
T TELECOMMUNICATIONS
R RESOURCE
SHEET IDENTIFICATION
TYPICAL MODIFIER CHARACTERS
B SUBSTRUCTURES
C CEILING/CHEMICALS
D DEMOLITION
E ELEMENTS
F FRAMING/FURNISHINGS
G GRAPHICS/GRADING
H HVAC
I INFORMATION/IMPROVEMENTS
L LIGHTING
N FINISHES
P PLAN/PIPING/POWER/PAVING/PLANTING
Q EQUIPMENT
S SITE
T TECHNOLOGY/TRANSPORTATION
U UTILITIES
ROOM TAG
REVISION TAG
KEYNOTE TAG
SECTION TAG
DETAIL TAG
EXTERIOR ELEVATION TAG
EXISTING ITEMS TO REMAIN
NEW WORK
EXISTING ITEMS TO BE
REMOVED
SYMBOLS LEGEND
NAME
A1
A-301
A1
A-501
INTERIOR ELEVATION TAG
NORTH ARROW
MATCH LINE
SEE - - - -
TOC
100'-0"
A1
PLAN OR DETAIL
SCALE: 1'-0" = 1'-0"
GRID
ELEVATION TAG
COLUMN/FND GRID
INDICATOR
MATCH LINE INDICATOR
VIEW TITLE
DOOR TAG
WINDOW TAG
101B
W1
PLAN NORTH
A-201A1
A-401A1
ISSUES
SHEET NUMBER
SHEET TITLE
A
2 3
1 2 3
4 5
4 5
A
TSP, Inc.
PROJECT
NOT
FO
R
CONSTR
UCTI
O N
600 Kansas City St.
Rapid City, SD 57701
(605) 343-6102 www.teamtsp.com
C C
B B
D D
© TSP, Inc. 2017
ISSUE DATE
CHECKED BY
DRAWN BY
PROJECT #
LI
S
TE
D
D R
A W
IN
G
S S
C A
LE
(S
) U N
LE
S
S R
E D
U C
E D
F R
O M
O R
IG
IN
A L x
F O
R M
A T
CONSULTANTS
Architecture Engineering
Planning
/7
/2
:4
:5
P
M
I:
T S
P R e v it L o c a l\
D a k o ta P la in s
K y le
C lin ic A jo h n s o n d p
.r v t
COVER SHEET
G-001
0%
D E
S
IG
N D
O C
U M
E N
T S
Kyle, South Dakota
KYLE CLINIC HEALTH
CENTER ADDITION -
IHS
DAKOTA PLAINS
---04/07/2017
---03161153
SHEET INDEX - GENERAL
G-001 COVER SHEET
G-101 LIFE SAFETY & CONSTRUCTION TYPES
SHEET INDEX - CIVIL
C-101 SITE REMOVALS
C-102 SITE LAYOUT
C-103 SITE GRADING AND DRAINAGE
C-104 SITE UTILITIES
C-501 DETAIL SHEET
SHEET INDEX - STRUCTURAL
S-001 STRUCTURAL GENERAL NOTES & TITLE SHEET
S-101 FOUNDATION & FIRST FLOOR FRAMING PLAN & DETAILS
S-102 ROOF FRAMING PLAN & DETAILS
S-501 SCHEDULES & DETAILS
SHEET INDEX - ARCHITECTURAL
AD-101 DEMOLITION PLAN
A-110 FLOOR & REFLECTED CEILING PLAN
A-201 EXTERIOR ELEVATIONS & ROOF PLAN
A-301 BUILDING & WALL SECTIONS
A-401 ENLARGED PLANS & INTERIOR ELEVATIONS
A-501 EXTERIOR DETAILS
A-502 INTERIOR DETAILS
A-601 SCHEDULES, WINDOW & DOOR TYPES
A-DEC PRELIMINARY LAYOUT FOR IHS KYLE (FOR REFERENCE ONLY)
SHEET INDEX - MECHANICAL
M-001 MECHANICAL TITLE SHEET
PD100 PLUMBING DEMOLITION PLAN - ADDITION CRAWLSPACE
PD101 PLUMBING DEMOLITION PLAN - ADDITION FIRST LEVEL
PL100 PLUMBING PLAN - ADDITION CRAWLSPACE
PL101 PLUMBING PLAN - ADDITION FIRST LEVEL
PL110 PLUMBING ROOF PLAN
PL601 PLUMBING SCHEDULES
M-100 OVERALL CRAWL SPACE PIPING PLAN
M-101 OVERALL BUILDING PIPING PLAN
MD101 MECHANICAL DEMOLITION PLAN - ADDITION FIRST LEVEL
MH100 MECHANICAL HVAC PLAN - ADDITION CRAWLSPACE
MH101 MECHANICAL HVAC PLAN - ADDITION FIRST LEVEL
MP100 MECHANICAL PIPING PLAN - ADDITION CRAWLSPACE
MP101 MECHANICAL PIPING PLAN - ADDITION FIRST LEVEL
M-120 MECHANICAL ROOF PLAN
M-601 MECHANICAL SCHEDULES
SHEET INDEX - ELECTRICAL
E-001 ELECTRICAL SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES
E-101 ELECTRICAL DEMOLITION AND LIGHTING PLANS
E-102 POWER AND TECHNOLOGY PLANS
E-103 LIGHTNING PROTECTION PLAN
E-401 ENLARGED PLANS - MECHANICAL/ ELECTRICAL ROOM
E-501 ELECTRICAL DETAILS AND RISER DIAGRAM
E-601 ELECTRICAL SCHEDULES
KYLE CLINIC HEALTH CENTER
ADDITION - IHS
100% DESIGN DOCUMENTS
04/07/2017
Kyle, South Dakota
DAKOTA PLAINS
MARK DATE DESCRIPTION
LIFE SAFETY LEGEND
TRAVEL DISTANCE
25'-0"
FIRE EXTINGUISHER CABINET FEC
FIRE EXTINGUISHER FE
EGRESS WIDTH/OCCUPANT LOAD SERVED
COMMON PATH
32" 160 OCC
OCCUPANT LOAD
CONCURRENT OCCUPANT LOAD
2HR FIRE WALL
2HR FIRE BARRIER
1HR FIRE BARRIER
1HR FIRE PARTITION
1HR SHAFT ENCLOSURE
2HR SHAFT ENCLOSURE
1HR SMOKE BARRIER
SMOKE PARTITION
2HR SMOKE BARRIER
AREA OF RENOVATION IS LIMITED TO
PROVIDING AUTOMATIC SPRINKLER SYSTEM
COMPLYING WITH IBC SECTION 903.3.1
(LIGHT GRAY HATCH)
AREA OF RENOVATION (DIAGONAL HATCH)
AREA OF MODIFICATION (CROSS HATCH)
NEW ADDITION
N E
W
E X
IS
T
IN
G
NEW
EXISTING
EXTG.
3'-10"
914 SF
MAIN PUBLIC WAITING
119 SF
VESTIBULE
120 SF
DENT. OPER
126 SF
DENT. OPER
118 SF
DENT. OPER
118 SF
DENT. OPER
119 SF
DENT. OPER
210 119 SF
DENT. OPER
67 SF
STORAGE
128 SF
DENTAL RECEPT.
24 SF
LKR.
TOTAL BUSINESS
OCCUPANCY AREA
18,960 SF GROSS
16,650 SF EXISTING
2,310 SF NEW
TOTAL OCCUPANCY = 190
PER IBC TABLE 1006.3.1: 3 EXITS REQUIRED
7 EXITS FROM FLOOR PROVIDED
(1 DOORS TO STAIR AND 7 EXITS AT GRADE)
TOTAL EXIT WIDTH REQUIRED: 562 x 0.2 = 112"
TOTAL EXIT WIDTH PROVIDED: 412.5"
D E
A D
E N
D
9'
0"
18 SF
JANITOR
100 SF
LAB
76 SF
SHARED STOR
56 SF
MED. ALC.
117 SF
LOUNGE
144 SF
SHARED OFFICE
107 SF
EXAM
107 SF
EXAM
73 SF
CLEAN
73 SF
SOIL
58 SF
NURSING
133 SF
N.S.
326 62 SF
FAMILY TLT
106 SF
OFFICE
150 SF
TREAT/ PROC
101 SF
EXAM
102 SF
EXAM
70.5"
34.5"
34.5"
34.5"
DW=3' - 0"DW=3' - 0"
45 SF
STORAGE
39 SF
X-RAY
56 SF
SUP.OFF.
4' -4
4'-10"
DW=3' - 0"
FLOOR HATCH
AREA OF MODIFICATION (CROSS HATCH)
4' - 5 3/4"
FEC
FEC
FEC
FEC
FEC
FEC
FEC
4' -0
5' -0
FEC
GOVERNING CODES:
BUILDING
2015 INTERNATIONAL BUILDING CODE
2014 EDITION OF THE FACILITIES GUIDELINES INSTITUTE (FGI)
GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITALS
AND OUTPATIENT FACILITIES (CHAPTER 3)
ACCESSIBILITY
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
FIRE /LIFE SAFETY
2012 NFPA 101 LIFE SAFETY CODE
MECHANICAL
2015 INTERNATIONAL MECHANICAL CODE
PLUMBING
2015 UNIFORM PLUMBING CODE
ELECTRICAL
2014 NATIONAL ELECTRICAL CODE
CODE SUMMARY
B Outpatient ClinicOccupancy Classification:
Type II-B
Existing is Non-sprinkled. Sprinklers will be added.
Addition is to be sprinkled.
Entire facility will be sprinkled per IBC Section 903.3.1
Type of Construction:
Total Building Height = 23'-4"Actual Height:
IBC Table 504.3 = 55 ftAllowable Height:
Actual Areas:
IBC Table 506.2 = 23,000 sfAllowable Area:
PLUMBING FIXTURE REQUIREMENTS
W.C. Men - 2 4 W.C. Women - 2 4 LAV. Men - 2 4 LAV. Women - 2 4 Unisex Toilet Rooms - 0 7 Drinking FT - 2 3 Service Sink - 1 1
Fixtures Required
Fixtures Provided
IBC Table 2902.1 - B Business 95 Men and 95 Women (for entire facility)
Common Path of Travel (IBC Table 1006.2.1): 100 ft max.
Fire resistive Rating Requirements (Table 601):
Structural Frame 0 Exterior Bearing Walls 0 Interior Bearing Walls 0 Exterior Non Bearing Walls (per table 602) 0 Interior Non Bearing Walls 0 Floor Construction 0 Roof Construction 0
Building Element Rating (in hours)
Storage Smoke Partition
(NFPA 8.7.1.2)
Waste and Linen Collection Smoke Partition (IBC Table 509)
Incidental Use Separation :
(IBC)
Special Hazard Protection
(NFPA)
CHAPTER 3
CHAPTER 5
CHAPTER 6
CHAPTER 9
CHAPTER 10
CHAPTER 29
First Floor = 20,000 sf Penthouse = 1,128 sf Total Building = 21,128 sf
Egress Width (IBC Section 1005.3.3): 190 x .2 = 38" total
Corridors (IBC Table 1020.1): Serving greater than 30 occupants with sprinker system do not need to be rated.
PROJECT ADDRESS:
KYLE HEALTH CENTER
KYLE, SD
Total Building Stories = 2 (1 Occupied Floor + Mechanical Penthouse)Actual Stories Above Grade:
IBC Table 504.4 = 3Allowable Stories Above Grade:
Travel Distance to Exit (IBC Table 1017.2): 300 feet max.
Dead-End Corridors (IBC Table 1020.4): 50 feet max.
Minimum Number of Exits per floor: 2 (4 provided) (IBC Table 1006.3.1)
NOTE: EACH UNISEX TOILET ROOM INCLUDES
ONE TOILET AND ONE LAVATORY.
Max. Travel to Fire Extinguisher (IBC Section 906.3): 75 ft
S E
C T
IO
N
(A T
F
LO
O R
P
LA
N
S E
C T
IO
N
(A T
C E
IL
IN
G
S E
C T
IO
N
(A T
D E
C K
4" PARTITION - CHASE
WALL ASSEMBLY
- 5/8" GYPSUM BOARD
- 3 5/8" METAL STUDS
S E
C T
IO
N
(A T
F
LO
O R
P
LA
N
S E
C T
IO
N
(A T
C E
IL
IN
G
S E
C T
IO
N
(A T
D E
C K
UL DESIGN NO. U442
5" PARTITION - 1HR
WALL ASSEMBLY
- 5/8" GYPSUM BOARD
- 3 5/8" METAL STUDS
- 5/8" GYPSUM BOARD
= PROVIDE SOUND INSULATION
SOUND
INSULATION AT
TYPE 'A3CS' ONLY
= PROVIDE SOUND INSULATION
SOUND
INSULATION AT
TYPE 'A3AS' ONLY
S E
C T
IO
N
(A T
F
LO
O R
P
LA
N
S E
C T
IO
N
(A T
C E
IL
IN
G
S E
C T
IO
N
(A T
D E
C K
UL DESIGN NO. U465
7" PARTITION - 1HR
WALL ASSEMBLY
- 5/8" GYPSUM BOARD
- 6" METAL STUDS
- 5/8" GYPSUM BOARD
= PROVIDE SOUND INSULATION
SOUND
INSULATION AT
TYPE 'A6AS' ONLY
S E
C T
IO
N
(A T
F
LO
O R
P
LA
N
5" FURRING
WALL ASSEMBLY
- 5/8" GYPSUM BOARD
- 3 5/8" METAL STUDS
FACE OF
WALL
BRACE PARTION
TO STRUCT.
ABOVE. REF SPEC.
STUDS & GYP. BD.
TO EXTEND 4" TO
6" ABOVE CEILING
4 7/8" 4 1/4" 7 1/4" 4 1/4" 1/2"
A3AS
A3A
A3CS
A3C
A6AS
A6A D3B
= PROVIDE SOUND INSULATIOND3BS
S E
C T
IO
N
(A T
F
LO
O R
P
LA
N
S E
C T
IO
N
(A T
C E
IL
IN
G
S E
C T
IO
N
(A T
D E
C K
UL DESIGN NO. U465
5" PARTITION - 1HR (LEAD)
WALL ASSEMBLY
- 5/8" GYPSUM BOARD
- 3 5/8" METAL STUDS
- 5/8" LEAD LINED
GYPSUM BOARD
= PROVIDE SOUND INSULATION
SOUND
INSULATION AT
TYPE 'A3ES'
ONLY
LEAD LINED
GYP. BD. TO
7'-0" AFF
U.N.O
4 7/8"
A3ES
A3E
S E
C T
IO
N
(A T
F
LO
O R
P
LA
N
3" FURRING
WALL ASSEMBLY
- 5/8" GYPSUM BOARD
- 2 1/2" METAL STUDS
FACE OF
WALL
BRACE PARTION TO
STRUCT. ABOVE.
REF SPEC. STUDS &
GYP. BD. TO
EXTEND 4" TO 6"
ABOVE CEILING
3 1/8" 1/2"
D2B
MB1
EXTERIOR WALL
CMU WITH MASONRY
WALL ASSEMBLY
- 5/8" GYPSUM WALL BOARD
- 2 1/2" RIGID INSULATION - TAPED JOINTS
- AIR BARRIER
- 6" CONCRETE MASONRY UNITS
- FLUID-APPLIED WEATHER BARRIER
- AIR SPACE
- 4" MASONRY, 4" FACE BRICK, OR SOILDER COURSE
(REF ELEVATIONS & WALL SECTIONS)
FLOOR CONSTRUCTION
FLOOR ASSEMBLY:
- 4" CONCRETE FLOOR (REF STRUCT)
- 1 1/2" METAL FLOOR DECK (REF STRUCT)
- STRUCTURAL STEEL (REF STRUCT)
* REF STRUCTURAL FOR ADDITIONAL INFORMATION
ROOF CONSTRUCTION
ROOF ASSEMBLY:
* REF STRUCTURAL FOR ADDITIONAL INFORMATION
- ADHERED ROOFING MEMBRANE
- TAPERED RIGID ROOF INSULATION
- 4" BASE LAYER RIGID ROOF INSULATION
- CLASS 1 VAPOR RETARDER
- METAL DECK
- STEEL BEAM OR JOIST
F2 R1
1'-1"
FLOOR CONSTRUCTION
FLOOR ASSEMBLY:
- 2" SAND
- VAPOR BARRIER
- GRADED SOIL
* REF STRUCTURAL FOR ADDITIONAL INFORMATION
F1
PROVIDE MINIMUM AVERAGE R-38
NORTH
(ACTUAL)
NORTH
(REFERENCE)
ISSUES
SHEET NUMBER
SHEET TITLE
A
2 3
1 2 3
4 5
4 5
A
TSP, Inc.
PROJECT
NOT
FO
R
CONSTR
UCTI
O N
600 Kansas City St.
Rapid City, SD 57701
(605) 343-6102 www.teamtsp.com
C C
B B
D D
© TSP, Inc. 2017
ISSUE DATE
CHECKED BY
DRAWN BY
PROJECT #
LI
S
TE
D
D R
A W
IN
G
S S
C A
LE
(S
) U N
LE
S
S R
E D
U C
E D
F R
O M
O R
IG
IN
A L x
F O
R M
A T
CONSULTANTS
Architecture Engineering
Planning
KEY PLAN
EXTG. BLDG.
NEW ADDITION
/6
/2
:1
:2
P
M
I:
T S
P R e v it L o c a l\
D a k o ta P la in s
K y le
C lin ic A jo h n s o n d p
.r v t
LIFE SAFETY &
CONSTRUCTION
TYPES
G-101
0%
D E
S
IG
N D
O C
U M
E N
T S
Kyle, South Dakota
KYLE CLINIC HEALTH
CENTER ADDITION -
IHS
DAKOTA PLAINS
AJP04/07/2017
DPJ03161153
SCALE: 1/16" = 1'-0"
C1
FIRST LEVEL CODE PLAN
LEGEND - PARTITION TYPES
MARK DATE DESCRIPTION
LEGEND - CONSTRUCTION TYPES
meyerdr Rectangle meyerdr Text Box
- SUBSTRATE BOARD
meyerdr Callout
THIS IS A 1/4" BOARD OVER ROOF DECK
AND
ANGLE
DOUBLE ANGLE
AT
CENTER LINE
PARALLEL
PENNEY
PERPENDICULAR
PLATE
POUND OR NUMBER
ROUND OR DIAMETER
ARCHITECTURAL AND
ENGINEERING
ANCHOR BOLT/ROD
ABOVE
ADDENDUM
ADHESIVE
ADJUSTABLE, ADJACENT,
ADJOINING
ABOVE FINISH FLOOR
AGGREGATE
ANCHOR, ANCHORAGE
ALTERNATE
APPROXIMATE
ARCHITECT (URAL)
BEVELED
BELOW FINISH FLOOR
BRICK LEDGE
BLOCK (ING)
BEAM
BOTTOM
BOTTOM OF
BOTTOM OF CONCRETE
BOTTOM OF FOOTING
BEARING
BRICK
BASEMENT
BETWEEN
CHANNEL
CUBIC FEET OR FOOT
CHAMFER
CAST-IN-PLACE CONCRETE
CONTROL JOINT
CENTER LINE
CONCENTRATED LOAD
CEILING
CLEAR,CLEARANCE
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
CONNECT (ION)
CONSTRUCTION
CONTINUOUS, CONTINUE
CONTRACT (OR)
COORDINATE
CORRUGATED
CENTER
CUBIC YARD
L
LL
C d P Ø
A&E
AB
ABV
ADDM
ADH
ADJ
AFF
AGGR
AHR
ALT
APPROX
ARCH
BEV
BFF
BL
BLK
BM
BOT
BO
BOC
BOF
BRG
BRK
BSMT
BTWN
C
CF
CHFR
CIPC
CJ
CL
CL
CLG
CLR
CMU
COL
CONC
CONN
CONSTR
CONT
CONTR
COORD
CORR
CTR
CY
L
L
ABBREVIATIONS:
SYMBOLS USED AS ABBREVIATIONS:
EACH
EACH FACE
EXPANSION JOINT
ELEVATION
EMBED (ED)
EQUAL
EQUIPMENT
ESTIMATE
EACH WAY
EXISTING
EXPANSION
EXPOSED
EXPANSION BOLT
EXTERIOR
FLOOR DRAIN
FINISH FLOOR ELEVATION
FINISH (ED)
FLANGE
FLOOR (ING)
FOUNDATION
FACE OF
FACE OF CONCRETE
FACE OF MASONRY
FACE OF STUD
FACE OF WALL
FOOT, FEET
FOOTING
FAR SIDE
FUTURE
EA
EF
EJ
EL
EMB
EQ
EQUIP
EST
EW
EXIST
EXP
EXP
EXP BT
EXT
FD
FFE
FIN
FLG
FLR
FND
FO
FOC
FOM
FOS
FOW
FT
FTG
FS
FUT
DOUBLE
DEMOLITION, DEMOLISH
DETAIL
DIAMETER
DIAGONAL
DIMENSION
DIVIDE, DIVISION
DEAD LOAD
DRAIN
DRAIN TILE
DRAWING (S)
DBL
DEMO
DET
DIA
DIAG
DIM
DIV
DL
DR
DT
DWG
GAGE, GAUGE
GALVANIZED
GENERAL CONTRACTOR
GLU LAMINATED (BEAM)
GRADE BEAM
GRATING
GYPSUM
GA
GALV
GC
GLU-LAM
GR BM
GRTG
GYP
HEIGHT
HEADED ANCHOR BOLT
HEADED ANCHOR STUD
HOLLOW CORE
HEADER
HORIZONTAL
HOLLOW STRUCTURAL SHAPE
HEIGHT
H
HAB
HAS
HC
HDR
HORIZ
HSS
HT
INSIDE DIAMETER
INCLUDE (D), INCLUDING
INSULATE (D), INSULATION
INTERIOR
INVERT ELEVATION
ID
INCL
INSUL
INT
INV EL
THOUSAND POUND (KIP)
KEYED CONSTRUCTION JOINT
THOUSAND POUND
THOUSAND POUND PER LINEAR
FOOT
THOUSAND POUND PER SQUARE
FOOT
THOUSAND POUND PER SQUARE
INCH
K
KCJ
KIP
KLF
KSF
KSI
JOIST
JOINT
JST
JT
LENGTH
LAMINATE (ED)
POUND
LINEAR FEET
LIVE LOAD
LONG LEG HORIZONTAL
LONG LEG VERTICAL
LOCATION
LONGITUDINAL
LINTEL
LIGHTWEIGHT
LOUVER
L
LAM
LB
LF
LL
LLH
LLV
LOC
LONG
LTL
LT WT
LVR
MACHINE
MATERIAL
MAXIMUM
MEMBER
MISCELLANEOUS CHANNEL
MECHANICAL
MANUFACTURE (R)
MINIMUM
MISCELLANEOUS
METAL
MACH
MATL
MAX
MBR
MC
MECH
MFR
MIN
MISC
MTL
NOT APPLICABLE
NOT IN CONTRACT
NUMBER
NEAR SIDE
NON-SHRINK, NON-METALLIC
NOT TO SCALE
NA
NIC
NO
NS
NSNM
NTS
ON CENTER
OUTSIDE DIAMETER
OVERHEAD
OPPOSITE
OC
OD
OH
OPP
PARALLEL
POUNDS PER CUBIC FOOT
PEDESTAL
PERFORATED
PERPENDICULAR
PRECAST
PREFABRICATE
PLATE
POUNDS PER LINEAR FOOT
PLYWOOD
PANEL
PAIR
POUNDS PER SQUARE INCH
POUNDS PER SQUARE FOOT
POST TENSION (ED)
POINT
POLYVINYL CHLORIDE
PAR
PCF
PED
PERF
PERP
PC
PREFAB
PL
PLF
PLYWD
PNL
PR
PSI
PSF
PT
PT
PVC
SECTION
SHEET
SHEATHING
SIMILAR
SLEEVE
SEALANT
SLAB-ON-GRADE
SPECIFICATION (S)
SQUARE
STAINLESS STEEL
STANDARD
STEEL
STRUCTURAL
SUSPENDED
SYMMETRY, SYMMETRICAL
SECT
SHT
SHTHG
SIM
SLV
SLNT
SOG
SPEC
SQ
SST
STD
STL
STRUCT
SUSP
SYMM
RADIUS/RISE (R)
REINFORCED CONCRETE PIPE
REFERENCE
REINFORCE (D), (ING)
REQUIRE
REQUIRED
REVISION (S), REVISED
ROUGH OPENING
REVERSE (SIDE)
R
RCP
REF
REINF
REQ
REQD
REV
RO
RVS
TREAD
TOP AND BOTTOM
TONGUE AND GROOVE
TO BE DETERMINED
THREAD (ED) (S)
THICKNESS
THROUGH
TOTAL LOAD
TOP OF
TOP OF BEAM
TOP OF CONCRETE
TOP OF FOOTING
TOP OF PIER
TOP OF SLAB
TOP OF STEEL
TOP OF WALL
TRANSVERSE
TUBE STEEL
TYPICAL
T T&B T&G
TBD
THD
THK
THRU
TL
TO
TO BM
TOC
TOF
TOP
TOS
TOS
TOW
TRANS
TS
TYP
UNLESS NOTED OTHERWISEUNO
SHEAR
VERTICAL
VAPOR RETARDER
V
VERT
VR
WIDTH
WITH
WITHOUT
WEDGE ANCHOR
WOOD
WIDE FLANGE
WIND LOAD
WORKING POINT
WEIGHT
WELDED WIRE FABRIC
W W/ W/O
WA
WD
WF (W)
WL
WP
WT
WWF
MOST COMMONLY USED STRUCTURAL ABBREVIATIONS
SYMBOLS LEGEND
TOP OF
FOUNDATION WALL
ELEVATION
TOP OF
FOOTING
ELEVATION
CORNER REINF
INDICATOR
CONTINUOUS
BEAM INDICATOR
FOUNDATION
WALL STEP
FOOTING
STEP
MASONRY PIER
INDICATOR
WALL
REINFORCING
INDICATOR
KEYNOTE
IDENTIFIER
REVISION
SYMBOL
DETAIL SECTION
INDICATOR
EQUIPMENT
INDICATOR
COLUMN/FND
GRID
INDICATOR
PC SPAN
IDENTIFIER
PIER TAG
INDICATORELEVATION TAG
ROOF SLOPE
INDICATOR
DETAIL
INDICATOR
WALL SECTION
INDICATOR
DETAIL BUBBLE
INDICATORS
BUILDING
SECTION
INDICATOR
EXTERIOR
ELEVATION
SYMBOL
TRUE NORTH
MAGNETIC
NORTH
PLAN NORTH
MATCH LINE INDICATOR DETAIL/SECTION/PLAN
INDICATOR
OPTIONAL
SYMBOLS
ADDED TO
PLAN NORTH
NORTH
ORIENTED
90° TO THE
SHEET
MATCH LINE
SEE - - - -
TOC
100'-0'
A1 A-101
A1 A-101
A1 A-101
A1 A-101
A1 A-101
TRUE N
ORTH
SPAN
12 XX" Ø X
XX'-X" XX'-X"
GRID1234
A
A
R
P1
100'-0" 99'-4" STP WALLSTP FTG
CONT
C1
PLAN NORTH
A1
PLAN OR DETAIL
SCALE: 1'-0" = 1'-0"
GENERAL STRUCTURAL NOTES
DESIGN CODE
1. INTERNATIONAL BUILDING CODE, 2015
DESIGN LOADS
1. FLOOR LOADS
CORRIDOR AND STAIR LIVE LOAD - 100 PSF
OFFICE FLOOR LIVE LOAD - 50 PSF
PLUS PARTITION SUPERIMPOSED FLOOR LIVE LOAD - 15 PSF
2. ROOF LIVE LOAD
GROUND SNOW LOAD Pg = 43 PSF FLAT ROOF SNOW LOAD Pf = 30 PSF SNOW EXPOSURE FACTOR Ce = 1.0
SNOW LOAD IMPORTANCE FACTOR I = 1.0
THERMAL FACTOR Ct = 1.0
PLUS APPLICABLE SLIDING, DRIFTING AND UNBALANCED SNOW LOAD INCREASES
3. CONCENTRATED LOADS AS SHOWN IN IBC TABLE 1607.1 SHALL BE ADDED TO THE UNIFORM LOADS
SHOWN ABOVE.
4. WIND LOADS
BASIC WIND SPEED = 115 MPH
RISK CATEGORY II (ASCE 7-10)
WIND EXPOSURE = C
5. SEISMIC LATERAL LOADS
RISK CATEGORY II (ASCE 7-10)
SPECTRAL RESPONSE COEFFICIENTS
SS (0.2 SEC)= 0.137g S1 (1.0 SEC)= 0.042g
SEISMIC IMPORTANCE FACTOR = 1.00
SITE CLASS D ASSUMED
SEISMIC DESIGN CATEGORY B
MATERIALS GRADES AND STRENGTHS
1. CAST-IN-PLACE CONCRETE
FOOTINGS, FOUNDATIONS, PIERS AND SLABS - 4000 PSI
2. MASONRY
CONCRETE MASONRY UNITS - ASTM C90
MASONRY CORE FILL AND BOND BEAMS - 3000 PSI
3. REINFORCING STEEL
BARS - ASTM A615 (GRADE 60)
BARS – ASTM A706 (WELDABLE REBAR) USE WHERE INDICATED
WELDED WIRE FABRIC - ASTM A185
4. STRUCTURAL STEEL
WIDE FLANGE SHAPES - ASTM A992 (Fy=50 KSI) PLATES AND OTHER SHAPES - ASTM A36 (Fy=36 KSI) HOLLOW STRUCTURAL SECTION (RECTANGULAR)- ASTM A500, GRADE B (Fy=46 KSI)
STEEL PIPE - ASTM A53
HIGH STRENGTH BOLTS, UNO - A325N
ANCHOR BOLTS/RODS - ASTM F1554, GRADE 36
EXPANSION BOLTS - HILTI KWIK BOLT III
HEADED STUDS - ASTM A108
5. LIGHT GAUGE STEEL FRAMING
STUDS, JOISTS & ACCESSORIES – ASTM A653, GRADE 33(Fy=33 KSI), G60 GALVANIZED
6. WOOD FRAMING (MISC.)
DIMENSION LUMBER - HEM-FIR #2 OR BETTER
MICROLAMS (LVL) – Fb=2600 psi, E= 1,900,000 psi, Fv =285 psi
SHEATHING (SUBFLOOR, ROOF, WALL) - APA RATED, THICKNESS,
GRADE AND EXPOSURE AS NOTED ON THE DRAWINGS
BOTTOM PLATES – TREATED HEM-FIR STUD GRADE
GENERAL
1. THE INFORMATION SHOWN ON THE STRUCTURAL DRAWINGS IS NOT TO BE SCALED, AS THE ITEMS
SHOWN MAY NOT BE TO SCALE FOR THE SPECIFIC LOCATION.
2. NO OPENINGS OR SLEEVES SHALL BE CUT OR PROVIDED IN WALLS OR FLOOR CONSTRUCTION
WITHOUT APPROVAL BY THE A/E.
3. EXAMINE ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS TO DETERMINE LOCATION AND DIMENSIONS OF CHASES, INSERTS, OPENINGS, SLEEVES, REVEALS, DEPRESSIONS
AND OTHER PROJECT REQUIREMENTS NOT SHOWN ON STRUCTURAL DRAWINGS.
4. BEFORE FABRICATION AND ERECTION OF ANY MATERIALS, FIELD VERIFY ALL EXISTING ELEVATIONS, DIMENSIONS AND CONDITIONS AS SHOWN ON THE DRAWINGS AND REPORT ANY DISCREPANCIES TO
THE ARCHITECT/ENGINEER AT ONCE FOR RESOLUTION.
5. STRUCTURAL MEMBERS INCLUDING JOISTS, SLABS, BEAMS, TRUSSES, COLUMNS AND WALLS ARE
DESIGNED FOR "IN PLACE" LOADS. CONTRACTOR IS RESPONSIBLE FOR BRACING, WITHOUT
OVERSTRESSING, ALL STRUCTURAL ELEMENTS (AS REQUIRED AT ANY STAGE OF CONSTRUCTION)
UNTIL COMPLETION OF THIS PROJECT.
FOUNDATIONS
1. FOOTINGS HAVE BEEN DESIGNED FOR A MAXIMUM SOIL BEARING PRESSURE OF 2000 PSF.
REFERENCE FMG, INC. REPORT FILE NO. 6243 DATED 12-17-1986 FOR THE EXISTING MEDICAL CLINIC (GEOTECHNICAL REPORT). CONTRACTOR SHALL FOLLOW THE RECOMMENDATIONS PROVIDED IN THE
GEOTECHNICAL REPORT FOR CONSTRUCTION OF SHALLOW SPREAD-FOOTING FOUNDATION
SYSTEM. SOILS/AGGREGATE SHALL MEET ALL MOISTURE, COMPACTION AND AGGREGATE
SIZE/GRADATIONS SPECIFIED IN THE PROJECT SPECIFICATIONS, GEOTECHNICAL REPORT OR AS RECOMMENDED BY GEOTECHNICAL ENGINEER/TESTING SERVICE, WHICHEVER IS MOST STRINGENT.
IF THE SOIL AT THE FOOTING ELEVATIONS SHOWN IS OF QUESTIONABLE BEARING VALUE, NOTIFY THE
ARCHITECT/ ENGINEER AT ONCE FOR RESOLUTION.
2. TESTING SERVICE MUST INSPECT AND APPROVE SUBGRADES AND FILL LAYERS BEFORE FURTHER CONSTRUCTION WORK IS PERFORMED THEREON. NOTIFY TESTING SERVICE PRIOR TO PROCEEDING
WITH PLACEMENT OF FOOTINGS, FILL, OR OTHER CONSTRUCTION OVER SUBGRADES AND FILL.
3. WATER SHALL NOT BE PERMITTED TO POND IN FOOTING EXCAVATION. KEEP EXCAVATION DRY.
FAILURE TO DO SO WILL BE CAUSE FOR REQUIRING CONTRACTOR TO REMOVE WATER DAMAGED
SOILS AND REPLACE WITH CONTROLLED FILL AS DIRECTED.
4. SHOULD ANY QUESTIONABLE CONDITIONS BE ENCOUNTERED DURING EXCAVATION, NOTIFY A/E IMMEDIATELY. FOOTING ELEVATIONS ARE SUBJECT TO CHANGE DEPENDING ON SOIL CONDITIONS
ENCOUNTERED.
5. REMOVE ANY ABANDONED SEWER OR SERVICE LINE ENCOUNTERED DURING EXCAVATION WITHIN
THE BUILDING LINES. SHOULD SUCH LINES BE FOUND BELOW OR ADJACENT TO FOOTING
LOCATIONS, NOTIFY THE A/E.
6. ALL FOOTINGS SHALL BE CENTERED UNDER WALLS. NO OFFSETS SHALL BE PERMITTED.
7. WALLS RETAINING SOIL HAVE BEEN DESIGNED FOR AN EQUIVALENT FLUID PRESSURE OF 40PCF.
ONLY FREE DRAINING GRANULAR FILL SHALL BE USED.
8. WHERE FILL MATERIAL IS PLACED ON BOTH SIDES OF GRADE BEAMS OR WALLS, IT SHALL BE PLACED IN LAYERS ALTERNATELY ON OPPOSITE SIDES TO MAINTAIN LEVELS THAT WILL AVOID
DISPLACEMENT OF, OR DAMAGE TO, THE WALLS OR BEAMS.
9. WHERE FILL MATERIAL IS PLACED ON ONE SIDE OF A WALL, THE WALL SHALL BE ADEQUATELY SHORED AND BRACED OR THE MATERIAL SHALL NOT BE PLACED UNTIL SUPPORTING FLOOR SLABS
HAVE BEEN POURED AND SET.
10. NO FILL OR BACKFILL SHALL BE "SETTLED" BY THE USE OF WATER.
11. PROVIDE DRAINAGE COURSE BELOW ALL INTERIOR, EARTH SUPPORTED, CONCRETE SLABS
UNLESS NOTED OTHERWISE. REFERENCE PLANS AND SPECIFICATIONS.
12. CONTINUOUS FOOTINGS SHALL BE STEPPED AT A SLOPE OF ONE VERTICAL TO ONE HORIZONTAL AT LOCATIONS NOTED ON THE PLANS OR AS REQUIRED FOR CONSTRUCTION. (REF DETAIL A1/S-501)
13. PROTECT IN-PLACE FOUNDATIONS AND SLABS ON GRADE FROM FROST PENETRATION UNTIL
PROJECT COMPLETION.
14. SLOPE BETWEEN ADJACENT FOOTINGS OR EXCAVATIONS SHALL NOT EXCEED ONE VERTICAL TO
TWO HORIZONTAL. STEP FOOTINGS DOWN AS NECESSARY TO MAINTAIN THIS SLOPE.
15. ALL EXTERIOR DOORS SHALL HAVE A FROST-FREE STOOP.
16. AT LOCATIONS IN WHICH UTILITIES PENETRATE THE FOUNDATION WALL, PROVIDE A SLEEVE IN THE
CONCRETE FOUNDATION WALL. (REF DETAIL A2/S-501)
CONCRETE
1. CODE FOR REINFORCED CONCRETE DESIGN AND CONSTRUCTION IS ACI 318, LATEST EDITION.
2. ARRANGEMENT AND BENDING OF REINFORCING STEEL SHALL BE IN ACCORDANCE WITH ACI DETAILING
MANUAL, LATEST EDITION
3. IN ADDITION TO OTHER REINFORCING NOTED, PROVIDE 2 - #5 ON EVERY SIDE OF EACH OPENING IN
CONCRETE WALLS. EXTEND #5 BARS 24" BEYOND EACH EDGE OF OPENING.
4. POLYPROPYLENE FIBER REINFORCING, FIBRILLATED, (BY FIBERMESH OR APPROVED EQUAL) IS TO BE USED FOR ALL INTERIOR AND EXTERIOR CONCRETE SLAB LOCATIONS SHOWN ON THESE STRUCTURAL
SHEETS AS TEMPERATURE AND SHRINKAGE REINFORCING. APPLY REINFORCING AT THE
MANUFACTURER'S RECOMMENDED RATE OR 1.5 LB/CY, WHICHEVER IS GREATER.
5. AT FLOOR DRAINS, SLOPE FLOOR UNIFORMLY THROUGHOUT THE ROOM TO THE DRAIN, (UNO).
6. ALL REINFORCING BARS SHALL BE LAP SPLICED WITH THE GREATER LENGTH OF A CLASS B TENSION LAP SPLICE OR 50 BAR DIAMETERS (FOR #6 BARS AND SMALLER) OR 62 BAR DIAMETERS (FOR #7 AND GREATER), EXCEPT WHERE NOTED OR DETAILED OTHERWISE. STAGGER LAPS IN SLABS AND WALLS.
SPLICE BARS IN GRADE BEAMS, STRUCTURAL SLABS, JOISTS, BEAMS, PILASTERS OR COLUMNS ONLY
WHERE SHOWN ON DRAWINGS OR SCHEDULES APPROVED BY A/E.
7. LAP W.W.F. WIRE SPACING PLUS 2" (6" MINIMUM).
8. MINIMUM CONCRETE COVER TO REINFORCING STEEL, UNO, SHALL BE AS FOLLOWS:
- SURFACES CAST AGAINST EARTH: 3"
- FORMED SURFACES IN CONTACT WITH EARTH OR EXPOSED TO WEATHER:
2" FOR #6 BAR OR LARGER
1-1/2" FOR #5 BAR OR SMALLER
- FORMED SURFACES NOT IN CONTACT WITH EARTH OR EXPOSED TO WEATHER:
- WALLS, SLABS, JOISTS: 3/4" FOR #11 BAR OR SMALLER
- BEAMS, COLUMNS, PIERS: 1-1/2”
9. DETAIL AND PROVIDE SUITABLE WIRE SPACERS, CHAIRS, TIES, ETC., FOR SUPPORTING REINFORCING
STEEL IN THE PROPER POSITION WHILE PLACING CONCRETE.
10. BAR SUPPORTS, WHICH COME IN CONTACT WITH EXPOSED SURFACES, SHALL HAVE PLASTIC OR RUBBER
TIPS OR BE STAINLESS STEEL.
11. PROVIDE HOOKED DOWELS OF SAME SIZE AND SPACING AS VERTICAL OR COLUMN REINFORCING AT THE FOUNDATION, UNLESS NOTED OTHERWISE. ALL HOOKED DOWELS SHALL BE TIED IN PLACE PRIOR TO
CONCRETE PLACEMENT.
12. PROVIDE BENT CORNER BARS TO MATCH AND LAP WITH HORIZONTAL BARS AT CORNERS AND
INTERSECTIONS OF WALLS, BEAMS, BOND BEAMS, AND FOOTINGS. (REF DETAIL B5/S-101)
13. WHERE CONSTRUCTION JOINTS ARE NOT SHOWN, OR WHEN ALTERNATE LOCATIONS ARE PROPOSED, DRAWINGS OF CONSTRUCTION AND CONTROL JOINTS LAYOUT AND PLACING SEQUENCE SHALL BE
SUBMITTED FOR APPROVAL PRIOR TO PREPARATION OF THE REINFORCING STEEL SHOP DRAWINGS.
14. HORIZONTAL CONSTRUCTION JOINTS ARE NOT PERMITTED IN CONCRETE MEMBERS UNLESS SHOWN ON THE DRAWINGS OR APPROVED IN ADVANCE. VERTICAL CONSTRUCTION JOINTS OR BULKHEADS SHALL BE
MADE AT MIDSPAN OR POINTS OF MINIMUM SHEAR.
15. PROVIDE KEYED CONSTRUCTION JOINTS (KCJ) IN SLABS AT LOCATIONS NOTED.
16. SIZE OF CONCRETE POURS BETWEEN CONSTRUCTION JOINTS SHALL BE LIMITED TO:
FOUNDATION WALLS: UNLIMITED (FROST DEPTH - NON-EXPOSED)
CONCRETE ON METAL DECK: 10,000 SQFT WITH A MAXIMUM DIMENSION OF 100 FT. WITH INTERMEDIATE CONSTRUCTION JOINTS LOCATED FROM GIRDERS ONE-THIRD THE BAY SPAN AND FROM PURLINS ONE-
THIRD THE PURLIN SPACING
17. VERIFY LOCATION OF OPENINGS SHOWN THROUGH CONCRETE SLABS OR WALLS AND COORDINATE ANY
ADDITIONAL REQUIRED OPENINGS WITH OTHER TRADES AND THE ARCHITECT/ENGINEER.
18. CONCRETE EXPOSED TO FREEZING AND THAWING SHALL CONTAIN 6%(+/- 1.5%) ENTRAINED AIR.
19. ALUMINUM CONDUIT OR PIPING MAY NOT BE EMBEDDED IN ANY CONCRETE.
20. CALCIUM CHLORIDE IS NOT PERMITTED IN ANY CONCRETE ADMIXTURES.
21. SUBMIT MIX DESIGN TO ENGINEER/ARCHITECT FOR APPROVAL PRIOR TO PLACING ANY CONCRETE.
22. CURE CONCRETE ACCORDING TO ACI 308.1 OR A COMBINATION OF MOISTURE CURING, COVER CURING, CURING COMPOUNDS, OR CURING & SEALING COMPOUNDS.
MASONRY
1. PROVIDE VERTICAL REINFORCEMENT IN EXTERIOR MASONRY WALLS THUS, UNO: #5 @ 48”OC
2. DOWEL VERTICAL WALL REINFORCING TO FOUNDATION WITH 1'-4" BARS OF SAME SIZE, UNO.
3. REINFORCE SIDES OF ALL OPENINGS AND CORNERS OF WALLS WITH (2) #5 VERTICAL FULL HEIGHT.
4. REINFORCE ALL BOND BEAMS WITH (2) #4 CONTINUOUS. REINFORCING TO BEND 1'-6" AROUND ALL CORNERS
OR USE 3'-0" CORNER BARS.
5. SHOP WELD ALL LINTEL UNITS.
6. PROVIDE 1/4" PLATE LINTELS AT RECESSED TOWEL DISPENSERS AND FIRE EXTINGUISHER CABINETS.
7. AT ALL UNFRAMED OPENINGS 3'-0" WIDE OR NARROWER, WHERE NO STEEL LINTEL IS INDICATED, PROVIDE REINFORCED CONCRETE BLOCK LINTELS. REINFORCE WITH 1-#5 PER 4" WALL THICKNESS. END BEARINGS 8" MINIMUM. NOTIFY A/E IF BEAM, JOIST OR COLUMN BEARING OCCURS ABOVE OPENING.
8. PROVIDE WELDED WIRE JOINT REINFORCING IN ALL MASONRY WALLS AT 16" O.C. MAXIMUM.
9. PROVIDE REINFORCING BARS AT LOCATIONS INDICATED ON THE DRAWINGS. LAP 48 BAR DIAMETERS AT
SPLICES IN VERTICAL WALL REINFORCING AND 48 BAR DIAMETERS ELSEWHERE (UNO).
10. GROUT CORES IN 5'-0" MAXIMUM LIFTS UNLESS CLEAN-OUTS ARE PROVIDED, IN WHICH CASE 8'-0"
MAXIMUM LIFTS MAY BE USED.
11. TIE VERTICAL REINFORCING TO JOINT REINFORCING AT 32" ON CENTER VERTICALLY TO MAINTAIN
POSITIONING WHILE GROUTING.
12. UNLESS DETAILED OR NOTED OTHERWISE, PROVIDE 1-#5 VERTICAL BELOW BEAM AND LINTEL BEARINGS AND GROUT CORE FULL HEIGHT. BEARING DISTANCE SHALL BE A MINIMUM OF 8". BEAM OR LINTEL SHALL BE SET IN GROUT, 1/2" MINIMUM DEPTH. PROVIDE 1-#5 VERTICAL, FROM TOP OF FOUNDATION TO TOP OF
WALL, IN CORES ADJACENT TO BEAM AND LINTEL BEARINGS AND GROUT CORE FULL HEIGHT.
13. ALL LINTELS AND LOOSE BRICK ANGLES TO BE TEMPORARILY SHORED UNTIL MASONRY HAS HARDENED.
14. CMU CORES CONTAINING VERTICAL REINFORCING SHALL BE GROUTED SOLID WITH CORE FILL
CONCRETE. FILLING CORES WITH MORTAR IS NOT ACCEPTABLE.
15. PLACE CONTROL JOINTS IN MASONRY WALLS SUCH THAT NO STRAIGHT RUN OF MASONRY EXCEEDS 25'-0" OR 1-1/2 TIMES THE WALL HEIGHT, WHICHEVER IS LESS, UNO. CONTROL JOINTS SHALL BE PROVIDED AT CHANGES IN WALL HEIGHT, CHANGES IN WALL THICKNESS AND WITHIN A DISTANCE OF 12'-0" OF CORNERS AND INTERSECTIONS. CONTROL JOINTS MAY NOT BE LOCATED ALONG THE EDGES OF
WALL OPENINGS OR BETWEEN THE OPENINGS AND THE ADJACENT GROUTED JAMBS.
16. UNLESS DETAILED OTHERWISE, CONSTRUCT NON-LOAD-BEARING MASONRY WALLS SUCH THAT THEY ARE BRACED AGAINST LATERAL MOVEMENT BY 14 GA. STEEL ANGLE, CONTINUOUS, EACH SIDE AT TOP OF WALL. CONNECT ANGLE TO ROOF OR FLOOR STRUCTURE. SNUG FIT CONNECTION TO MASONRY TO ALLOW FOR VERTICAL DEFLECTION OF ROOF OR FLOOR STRUCTURE WHILE INHIBITING LATERAL DEFLECTION OF
MASONRY WALL.
17. CONSTRUCT ALL LOAD BEARING OR NON-LOAD-BEARING MASONRY WALLS, WHETHER PARTIAL HEIGHT OR FULL HEIGHT, WITH A BOND BEAM AT THE TOP COURSE AND AT ROOF/FLOOR MEMBER BEARING LOCATIONS. THIS BOND BEAM IS TO BE REINFORCED WITH 2-#4 BARS, CONTINUOUS. PROVIDE ADDITIONAL BOND BEAMS SPACED AT A MAXIMUM OF 8’-0” OC VERTICALLY THROUGHOUT THE HEIGHT OF THE WALL. VERTICAL REINFORCING IN THE WALL IS TO EXTEND FULLY INTO (OR THROUGH) BOND BEAMS.
18. MASONRY STRENGTH NOTES: F'm = 1500 PSI, EXCEPT WHERE NOTED OTHERWISE ON DRAWINGS.
CONTRACTOR SHALL SUBMIT CERTIFICATION AND TESTING RESULTS AS REQUIRED TO ESTABLISH F’m BASED ON THE UNIT STRENGTH METHOD. MINIMUM COMPRESSIVE STRENGTH OF MASONRY UNITS IS 1900 PSI PER IBC TABLE 2105.2.2.1.2 FOR TYPE M OR S MORTAR. SUBMITTALS SHALL BE REVIEWED AND
APPROVED PRIOR TO MASONRY CONSTRUCTION STARTING.
19. SUBMIT MIX DESIGN OF CORE FILL CONCRETE AND BOND BEAM FILL CONCRETE TO
ENGINEER/ARCHITECT FOR APPROVAL PRIOR TO PLACING ANY CONCRETE.
20. PROVIDE CMU MASONRY BOND BEAM LINTELS OR STEEL ANGLE LINTELS BEARING ON 6" (MIN) SOLID MASONRY FOR ALL OPENINGS THROUGH MASONRY WALLS INCLUDING MECHANICAL AND ELECTRICAL
OPENINGS (REFERENCE PLAN & SCHEDULES ON S-501).
21. FILL CMU LINTELS SOLID WITH 3,000 PSI CONCRETE (3/8" MAXIMUM AGGREGATE).
STEEL FRAMING
1. TO AVOID UNDESIRABLE STRESSES IN PLATES OR THEIR ANCHORS, ALL WELDS SHALL BE MADE IN SINGLE PASSES IF APPLICABLE, SYMMETRICALLY AROUND THE PLATE. WHEN MULTIPLE PASSES ARE REQUIRED SUFFICIENT TIME SHALL BE ALLOWED BETWEEN PASSES FOR THE HEAT TO DISSIPATE.
2. LATEST AISC MANUAL AND SPECIFICATIONS APPLY.
3. WELDING ELECTRODES SHALL BE 70XX, UNO.
4. ALL WELDING AND TESTING OF WELDS SHALL BE IN ACCORDANCE WITH AMERICAN WELDING
SOCIETY CODES AND RECOMMENDATIONS.
5. ALL WELDING SHALL BE BY WELDERS HOLDING VALID CERTIFICATES IN THE REQUIRED WELD TYPE.
6. FULL PENETRATION WELDS SHALL BE ULTRASONICALLY TESTED BY AN INDEPENDENT TESTING LAB.
7. ALL HIGH STRENGTH BOLTED CONNECTIONS SHALL BE TIGHTENED TO THE TENSIONS SPECIFIED IN TABLE 4 OF AISC SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS.
TENSION MEASURING DEVICES SHALL BE USED TO CONFIRM BOLTS MEET THE REQUIREMENTS OF TABLE 4. MEASURING DEVICES SHALL INCLUDE LOAD INDICATING WASHERS OR ALTERNATE DESIGN
BOLTS (TWIST-OFF BOLTS).
8. ALL HIGH STRENGTH BOLTED CONNECTIONS (NOT WITHIN THE SLIP-CRITICAL CATEGORY NOR
SUBJECT TO TENSION LOADS NOR REQUIRED TO BE FULLY TENSIONED BEARING-TYPE
CONNECTIONS) SHALL BE TIGHTENED TO THE SNUG TIGHT CONDITION SPECIFIED IN THE AISC SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS, ARTICLE 8(c).
9. NOT ALL CONNECTIONS ARE DETAILED; SIMILAR DETAILS APPLY TO SIMILAR CONDITIONS UNLESS
OTHERWISE INDICATED. CONTACT THE ENGINEER OR ARCHITECT PROMPTLY TO VERIFY THE
DETAILS OF MEMBERS OR CONNECTIONS IN ANY SITUATION WHERE REQUIREMENTS ARE UNCLEAR.
CONTRACTOR SHALL PROVIDE THE NECESSARY BRACING DURING ERECTION AND UNTIL ALL STEEL IS
PLUMB AND SECURED.
10. FIELD CUTTING OR OTHER FIELD MODIFICATIONS TO STRUCTURAL STEEL SHALL NOT BE MADE
WITHOUT SPECIFIC PRIOR WRITTEN APPROVAL OF THE ARCHITECT/ENGINEER.
11. ALL BEAM COPES MUST BE MADE TO A RADIUS (3/4" MINIMUM).
12. STRUCTURAL STEEL FRAMING SHALL BE TRUE AND PLUMB BEFORE CONNECTIONS ARE FINAL
BOLTED OR WELDED.
13. INSTALL EXPANSION BOLTS IN ACCORDANCE WITH THE ICC REPORT RECOMMENDATIONS.
14. INSTALL DECK SUPPORT FRAMING AROUND ALL PENETRATIONS THROUGH STEEL FORM DECK AND
STEEL ROOF DECK, INCLUDING MECHANICAL OPENINGS AND ROOF DRAINS. CONTRACTOR TO
VERIFY AND COORDINATE LOCATIONS AND QUANTITIES. (REF DETAIL D1/S-102)
OPEN WEB STEEL JOISTS
1. DESIGN, FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE
STEEL JOIST INSTITUTE SPECIFICATIONS.
2. MANUFACTURER SHALL BE SJI APPROVED FOR THE TYPE OF JOIST BEING USED.
3. STEEL JOISTS SHALL BE DESIGNED FOR A DEAD LOAD (EXCLUDING WEIGHT OF JOISTS) OF 25 PSF
AND LIVE LOAD AS STATED UNDER DESIGN LOADS. WHERE JOISTS ARE DESIGNATED AS "SP",
CHORD SIZE DESIGNATION GIVEN IS FOR ESTIMATING PURPOSES ONLY. FINAL DESIGN SHALL BE PER LOADING DIAGRAM AND IS THE RESPONSIBILITY OF THE JOIST SUPPLIER. JOIST SUPPLIER SHALL
SUPPLY WEIGHT OF “SP” JOISTS ON SHOP DRAWINGS.
4. DESIGN MUST INCLUDE ALL CONCENTRATED LOADS FROM MECHANICAL EQUIPMENT,HEADERS,
SUSPENDED FOLDING PARTITIONS, ETC.
5. NO DRILLED HOLES OR CUTS ARE PERMITTED IN JOIST MEMBERS.
6. ALL CONCENTRATED LOADS SHALL BE APPLIED AT A JOIST PANEL POINT UNLESS THE JOIST
CHORDS ARE SPECIFICALLY DESIGNED FOR CONCENTRATED LOADS. (REF DETAIL D2/S-102)
7. BRIDGING SHALL BE HORIZONTAL OR DIAGONAL PER SJI SPECIFICATIONS.
8. DESIGN ROOF JOISTS FOR NET UPLIFT OF 15 PSF.
STEEL FORM DECK
1. STEEL DECK INSTITUTE SPECIFICATIONS AND RECOMMENDATIONS APPLY.
2. ALL FORM DECK SHALL BE 0.6", 22 GA GALVANIZED, UNO.
3. ALL DECK EDGES AT CMU WALLS SHALL BE SUPPORTED BY L3"x3"x1/4" CONTINUOUS DECK BEARING ANGLES ATTACHED TO THE CMU OR CONCRETE WALLS WITH 5/8" DIAMETER EXPANSION BOLTS (4”
EMBED) SPACED AT 32" OC INTO A CONTINUOUS BOND BEAM. (REF DETAIL B5/S-102)
4. DECK SHALL BE ERECTED AND WELDED TO SUPPORTING STEEL AND HAVE SIDE LAPS CONNECTED
ACCORDING TO THE MANUFACTURER'S SPECIFICATIONS.
5. LAP ENDS A MINIMUM OF 2" WITH THE CENTERS OF THE LAPS LOCATED AT THE CENTERS OF THE
SUPPORTS. AT COMPOSITE DECK PROVIDE BUTT JOINTS.
6. DECKING MUST BE CONTINUOUS OVER THREE SUPPORTS.
STEEL ROOF DECK
1. STEEL DECK INSTITUTE SPECIFICATIONS AND RECOMMENDATIONS APPLY.
2. ROOF DECK SHALL BE 1-1/2", 22 GA PAINTED WIDE RIB DECK, UNO.
3. ALL DECK EDGES AT CMU WALLS SHALL BE SUPPORTED BY L3"x3"x1/4" CONTINUOUS DECK BEARING ANGLES ATTACHED TO THE CMU WALLS WITH 5/8" DIAMETER EXPANSION BOLTS (4” EMBED) SPACED
AT 32" OC INTO A CONTINUOUS BOND BEAM. (REF DETAIL B3/S-102)
4. DECK SHALL BE ERECTED AND WELDED TO SUPPORTING STEEL WITH 5/8" DIAMETER PUDDLE WELD WITH 36/4 WELD PATTERN (UNO) AND HAVE SIDE LAPS CONNECTED WITH NO. 10 TEK SCREWS AT
MIDSPAN, UNO.
5. LAP ENDS A MINIMUM OF 2" WITH THE CENTERS OF THE LAPS LOCATED AT THE CENTERS OF THE
SUPPORTS.
6. DECKING MUST BE CONTINUOUS OVER THREE SUPPORTS.
COLD-FORMED STEEL (LT. GAGE) STRUCTURAL FRAMING
1. INTERIOR WALLS, REFERENCE ARCHITECTURAL FOR SIZE, 18 GA, GALVANIZED CSJ STUDS AT 16" OC.
2. MATERIAL, DESIGN AND MANUFACTURE SHALL BE IN ACCORDANCE WITH THE "COLD FORMED STEEL DESIGN MANUAL" OF THE AMERICAN IRON AND STEEL INSTITUTE CURRENT EDITION. PROVIDE STUDS OF TYPE, SIZE, GAGE, AND MANUFACTURER INDICATED ON THE DRAWINGS. DIFFERENT MANUFACTURERS MAY BE SUBSTITUTED PROVIDED THE STUDS HAVE THE SAME STRENGTH CHARACTERISTICS AS THOSE SPECIFIED ON THE DRAWINGS. THE CONTRACTOR SHALL SUBMIT MANUFACTURERS' INFORMATION ON
ALTERNATE STUD SUPPLIERS FOR APPROVAL.
3. PROVIDE TRACKS, BLOCKING, LINTELS, CLIP ANGLES, BRIDGING, SHOES, REINFORCEMENTS, FASTENERS AND ACCESSORIES TO PROVIDE A COMPLETE METAL FRAME SYSTEM IN ACCORDANCE
WITH MANUFACTURER'S RECOMMENDATIONS.
4. IN NON-BEARING, NON-EXTERIOR WALLS, FRAME WALL OPENINGS LARGER THAN 2'-0" SQUARE WITH DOUBLE STUD AT EACH JAMB OF FRAME EXCEPT WHERE MORE THAN 2 ARE SHOWN OR INDICATED.
INSTALL RUNNER TRACKS AND JACK STUDS ABOVE AND BELOW WALL OPENINGS. ANCHOR TRACKS TO JAMB STUDS BY WELDING, AND SPACE JACK STUDS SAME AS FULL HEIGHT STUDS OF WALL.
SECURE STUD SYSTEM WALL OPENING FRAME IN MANNER INDICATED.
5. CONSTRUCT NON-LOAD-BEARING STEEL STUD WALLS SUCH THAT THEY ARE BRACED AGAINST
LATERAL MOVEMENT BY A DEEP LEG TOP TRACK, CONTINUOUS. CONNECT DEEP LEG TRACK TO
ROOF OR FLOOR STRUCTURE. SNUG FIT CONNECTION TO STEEL STUD WALL TO ALLOW FOR
VERTICAL DEFLECTION OF ROOF OR FLOOR STRUCTURE WHILE INHIBITING LATERAL DEFLECTION OF
STEEL STUD WALL.
SUPPLEMENTAL NOTES
SPECIAL INSPECTION - IBC REQUIREMENTS
THE FOLLOWING WORK ITEMS REQUIRE SPECIAL INSPECTION PER IBC SECTION 1701 AND 1704. THE SPECIAL INSPECTION AND THE COST ASSOCIATED THEREWITH WILL BE PAID BY THE OWNER. THE
ITEMS THAT REQUIRE SPECIAL INSPECTIONS ARE:
A. 1705.2 STEEL CONSTRUCTION - REF AISC 360 FOR REQUIRED VERIFICATION AND INSPECTION OF
STEEL CONSTRUCTION
B. 1705.3 CONCRETE CONSTRUCTION - REF TABLE 1705.3 FOR REQUIRED VERIFICATION AND
INSPECTION OF CONCRETE CONSTRUCTION
C. 1705.4 MASONRY CONSTRUCTION - REF ACI 530 AND ACI 530.1 FOR REQUIRED VERIFICATION AND
INSPECTION OF MASONRY CONSTRUCTION.
D. 1705.6 SOILS – REF SECTION 1705.6 AND TABLE 1705.6 FOR REQUIRED VERIFICATION AND
INSPECTION OF SOILS.
BACKFILL/FILL
ENGINEERED FILL
DRAINAGE COURSE
ROCK/"SUGAR ROCK"
SCARIFY & RECOMPACT
CONCRETE
NATIVE UNDISTURBED SOIL
BRICK
CONCRETE MASONRY UNIT
METAL/STEEL
RIGID INSULATION/EIFS
GROUT
WOOD WALL/FINISH
MORTAR
PLYWOOD/OSB/PARTICLE
BOARD
WOOD-GLUED/LAMINATED
EXISTING AREAS / ELEMENTS
MATERIAL LEGEND
NORTH
(ACTUAL)
NORTH
(REFERENCE)
ISSUES
SHEET NUMBER
SHEET TITLE
A
2 3
1 2 3
4 5
4 5
A
TSP, Inc.
PROJECT
NOT
FO
R
CONSTR
UCTI
ON
600 Kansas City St.
Rapid City, SD 57701
(605) 343-6102 www.teamtsp.com
C C
B B
D D
© TSP, Inc. 2017
ISSUE DATE
CHECKED BY
DRAWN BY
PROJECT #
LI
ST
ED
D
R
AW
IN
G
S
SC
AL
E(
S) U
N
LE
SS
R
ED
U
C
ED
F R
O M
O R
IG
IN
AL
x
F
O
RM
AT
CONSULTANTS
Architecture Engineering
Planning
KEY PLAN
EXTG. BLDG.
NEW ADDITION
4/ 7/
1:
:5
A
M I:\
_T S
P R ev it
Lo ca l\0
D ak ot a P la in s
K yl e C lin ic
S
_W ei er sA
R .r vt
STRUCTURAL
GENERAL NOTES &
TITLE SHEET
S-001
0%
D
ES
IG
N
D O
C U
M
EN
TS
Kyle, South Dakota
KYLE CLINIC HEALTH
CENTER ADDITION -
IHS
DAKOTA PLAINS
ARW04/07/2017
CSH03161153
SHEET INDEX - STRUCTURAL
C D
I s s u e
SHEET # SHEET NAME
S-001 STRUCTURAL GENERAL NOTES & TITLE SHEET
S-101 FOUNDATION & FIRST FLOOR FRAMING PLAN & DETAILS
S-102 ROOF FRAMING PLAN & DETAILS
S-501 SCHEDULES & DETAILS
KEY NOTES:
SHEET GENERAL NOTES:
DENT.
OPER
DENT.
OPER
X-RAY
EXAM
EXAM
EXAM
PHYS. OFF.
CLEAN
UTILITYCAST RMTREATMENT
TLT
N.S.
VITALS
LOUNGE
MED. ALC.
SHARED
STOR
LAB
SHARED
OFFICE
EXAM
EXAM
EXAM
EXAM 320
TREAT/
PROC
N.S.
FAMILY TLT
OFFICE
NURSING
CLEAN
SUP.OFF.
SOIL
STORAGE
CORR.
CORR.
CORR.
CORR.
HALL
W.C. ALC.
HALL
323A
VEST.
5'-0"
CC
BB
AA
1.7
1.7
'-4
'-6
'-7
/8
'-1
3/ 8"
W
X2
W
X2
W
X3
TO
S=
9'
1/ 2"
W
X2
FI
EL
D
VE
R
IF
Y
EX
IS
T
K
ST
EE
L
BA
R
JO
IS
TS
'-0
"O C
FIELD VERIFY
EXIST 14K STEEL BAR JOISTS @ 2'-0"OC
" E
XI
ST
1' -0
K5 S
TE
EL
B
AR
J O
IS
TS
S
PA
CE
D
'-0 "O
C (M
AX
1' -6
" E
XI
ST
6"
K1 S
TE
EL
B
AR
J O
IS
TS
S
PA
CE
D
'-0 "O
C (M
AX
2' -0
K1 S
TE
EL
B
AR
J O
IS
TS
S
PA
CE
D
'-0 "O
C (M
AX
2' -0
HSS4X4X1/4
HSS4X4X1/4
HSS4X4X1/4
A.3A.3
B.5B.5
A.9A.9
3" (TOTAL DEPTH) NON-COMPOSITE
POLYFIBER REINF CONCRETE FLOOR SLAB
REINF W/ 6X6-W1.4XW1.4 WWF ON METAL
DECK CONSISTING OF 2.4" CONCRETE ON
0.6"X22GA GALVANIZED FORM DECK
TOC ELEV = 100'-0" (MATCH EXISTING ELEV)
D2
S-101
D4
S-101
TYP
A5
S-101
D1
S-101
D1
S-101
D3
S-101TYP
A5
S-102
B5
S-102
(T
YP
B5
S-102 SIM
D1
S-101
TYP
B2
S-501
B1
S-501
TYP
TYP
CC
BB
AA
'-4
'-4
'-0
42'-8"
25'-7 7/16" 9'-0 9/16" 8'-0"
1.7
1.7
3'-0"
10"
3' -0
'-4
'-6
'-7
/8
'-1
3/ 8"
1' -6
A.3A.3
B.5B.5
A.9A.9
'-6
6'
-0
'-1
0"
5'-0"
7'-0"X7'-0"X1'-0" THICK
CONCRETE FOOTING REINF
W/ (7)#5 EACH WAY BOTTOM
TOF ELEV = 94'-0"
6'-0"X6'-0"X1'-0" THICK
CONCRETE FOOTING REINF
W/ (7)#5 EACH WAY BOTTOM
TOF ELEV = 94'-0"
TOF EL= 94' - 0"
TOF EL= 94' - 0"
D2
S-101
D4
S-101
TYPA5
S-101
D1
S-101
D1
S-101
FIELD VERIFY
2'-6" EXIST
FIELD VERIFY
10" EXIST
FIELD VERIFY
2'-6" EXIST
FIELD VERIFY
10" EXIST
FIELD VERIFY
2'-6" EXIST
FIELD VERIFY
10" EXIST
EXISTING CRAWLSPACE
NEW CRAWLSPACE W/ 4" CLEAN SAND
ATOP VR ATOP GEOTECH APPROVED
PROPERLY COMPACTED SOILS,
TOP OF SAND ELEV = 95'-0" +/-
D3
S-101
TYP
8"
REF CIVIL PLANS
FOR RETAINING
WALL DETAIL
5'-0"X4'-0"X1'-0" THICK
CONCRETE FOOTING REINF
W/ #5 @ 12"OC EA WAY BOT
TOF ELEV = 94'-0"
REF DETAIL B1/S-501
4'-0"X3'-0"X1'-6" THICK
CONCRETE FOOTING
-REF DETAIL B2/S-501
12" SQ
PIER10
2' -2
4'-0"
B2
S-501
B1
S-501
5'-0"1' -0
" 12" SQ
PIER
D1
S-101
TYP
NOTE: NOT ALL KEYNOTES MAY BE USED ON EACH PLAN
FOUNDATION AND FLOOR FRAMING PLANS
1. OPENING FOR FLOOR HATCH ACCESS TO CRAWLSPACE:
- REFERENCE DETAIL D1/S-102 FOR PERIMETER SUPPORT FRAMING MEMBERS
- CONTRACTOR COORDINATE OPENING SIZE W/ FLOOR JOIST SUPPLIER CHORD DIMENSIONS AND
FLOOR HATCH SUPPLIER ROUGH OPENING & INSTALLATION REQUIREMENTS
- (*) JOIST SPACING MAY BE WIDER THAN 2'-0"OC, AT THIS LOCATION ONLY, TO ALLOW FLOOR
HATCH INSTALLATION
2. TIE EXISTING FOUNDATION DRAIN TO NEW AND CONTINUE AROUND ADDITION
- REFERENCE DETAIL A5/S-101 & CIVIL PLANS
- VERIFY EXISTING SYSTEM & DEPTH AND MAINTAIN POSITIVE DRAINAGE
3. TIE EXISTING FOUNDATION DRAIN TO NEW AND CONNECT TO EXISTING OUTLET
- REFERENCE CIVIL PLANS & DETAIL A5/S-101
- VERIFY EXISTING SYSTEM & DEPTH AND MAINTAIN POSITIVE DRAINAGE TO OUTLET
4. DOWEL STOOP SLAB REINFORCEMENT TO RETAINING WALLS & BUILDING FOUNDATION WALL
W/ #4X24"X24" @ 12"OC CAST-IN-PLACE AS INDICATED IN STOOP DETAIL D2/S-101 OR PROVIDE
STRAIGHT #5X24" DRILL & EPOXY DOWELS (4" EMBED) @ 12"OC
A. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS- IF ANY NEW
CONSTRUCTION CONFLICTS WITH EXISTING CONDITIONS CONTRACTOR SHALL NOTIFY
ARCHITECT/ENGINEER FOR RESOLUTION BEFORE PROCEEDING WITH CONSTRUCTION
B. USE HILTI HIT-HY 200 ADHESIVE SYSTEM OR APPROVED EQUAL AT ALL DRILL & EPOXY ANCHOR
BOLT OR REBAR DOWEL CONNECTIONS
C. REFERENCE SHEET S-501 FOR BEAM/COLUMN CONNECTION SCHEDULE, LINTEL SCHEDULE
& TYPICAL DETAILS
D. COORDINATE ANY NEW AND EXISTING PIPING, CONDUIT, OR OTHER PENETRATIONS THROUGH
THE FLOOR SLAB WITH STRUCTURAL FRAMING/STEEL DECK
- AT NEW PENETRATIONS: ANY THAT EXCEED 6" DIAMETER OR GROUPS OF CLOSELY SPACED
PENETRATIONS PROVIDE SUPPORT FRAMING SIMILAR TO DETAIL D1/S-102
- AT EXISTING PENETRATIONS TO BE ABANDONED: FASTEN PLATE TO BOTTOM OF DECK &
GROUT FULL
FOUNDATION & FLOOR FRAMING PLANS
CORNER BAR SAME
SIZE & SPACING AS
LONG BAR x 4'-0" LONG
DOWEL BAR SAME SIZE
& SPACING AS LONG
BAR x 2'-6" LONG
REF SITE PLANS FOR
SIDEWALK/PAVING:
#4x12" DOWEL @ 16"OC
-GREASE THIS END
DRAINAGE COURSE
#4 DOWELS (24"x24")
@ 12" OC (ALL SIDES)
#4 @ 18" EA WAY
(ALL SIDES)
#5 CONT
5" CIPC SLAB W/ #4
@12" OC EW BOT
HOLD SLAB DOWN
1/4" @ THRESHOLD
SLOPE 1/4"/FT
1/2" ISOLATION JOINT
W/ SEALANT
#4 x OPENING WIDTH
+ 4'-0" (CENTERED)
6" WALL
CONC SLAB ON METAL DECK
(POUR THRU OPENING)
REF EXT FND
DETAIL
TOC/FIRST LEVEL
REF PLAN
TOF
REF PLAN
REF PLAN
BEGIN RETAINING
WALL FOOTING
EACH SIDE
FND WALL BEYOND
CMU WALL (REF PLAN)
MASONRY
VENEER
2'-6" DOWEL (EMBED 16")
TO MATCH WALL REINF
SIZE & SPACING
HOOK DOWEL TO MATCH
VERT REBAR SIZE &
SPACING (ALTERNATE
LEG EACH DIRECTION)
FOOTING
(REF PLAN)
CMU WALL REINF
(REF S-001 & PLAN)
INSULATION (REF ARCH DWGS)
1/2" ISOLATION JOINT
CONC SLAB ON
METAL DECK
#5 @ 12"OC EACH WAY
(TYP)
RIGID INSULATION
(REF ARCH)
(4) #5
CONT
TOC/FIRST LEVEL
REF PLAN
TOF
REF PLAN
REF PLAN
BRICK LEDGE
REF ARCH
WRAP W/
FILTER FABRIC
DRAIN TILE
TILE FILL
8"
4"X6"X1/2" BRG PL W/
1/2"ØX4" HAS- GROUT
JOIST BEARING
POCKET FULL
3/16 2"
JST TO PL
GRID
4' -0
" A
FF
GEOTECH APPROVED STIFF SILT SOILS
OR ENGINEERED FILL (REF S-001)
NEW CRAWLSPACE-
REF PLAN
(2) #5 CONT @ TOP
30# FELT BETWEEN
CONCRETE & COLUMN
3/4"X10"X10" BASEPLATE
W/ (4)3/4"Ø HAB & 1-1/2"
NSNM GROUT
(4)#7 VERTS & (3)#3 TIES @ 3"OC
TOP AROUND ANCHOR BOLTS
THEN SPACE TIES @ 12"OC
DOWELS TO MATCH
VERT REINF
FOOTING
(REF PLAN)
GRID
STEEL BEAM
(REF PLAN)
STEEL COLUMN
(REF PLAN)
1/4"
STEEL JOIST
(REF PLAN)
CLEAN SAND ATOP
VAPOR RETARDER
4" 1'
-0
1' -0
GEOTECH APPROVED STIFF SILT SOILS
OR ENGINEERED FILL (REF S-001)
REF CONNECTION
SCHEDULE C4/S-501
TOP ELEV
98'-0"
1'-4" Ø (MIN)
NEW EXISTING
#5 x 1'-0" DOWELS @ 12" OC
VERT INTO EXISTING
FOUNDATION WALL W/
HILTI HIT HY200 ADHESIVE
#5 x 1'-0" DOWELS @ 12" OC
HORIZ INTO EXISTING FOOTING
W/ HILTI HIT HY200 ADHESIVE
EXIST CMU
WALL
-VERIFY
CONC SLAB ON
METAL DECK
- REF PLAN
#4 HORIZ & VERT/L-BAR @ 12"OC
EXISTING
CRAWLSPACE
#5 CONT
@ TOP
TOC/FIRST LEVEL
REF PLAN
4"X6"X1/2" BRG PL W/
1/2"ØX4" HAS
3/16 2"
JST TO PL
GRID
1'-2"
6" 1'
-0
STEEL JOIST-
REF PLAN
NEW CRAWLSPACE-
REF PLAN
#5 DOWELS @ 24"OC- DRILL
& EPOXY SET (6" EMBED)
2'-0"
6" 6"
#5X8"X18" DOWEL T&B
@ 48"OC - DRILL &
EPOXY SET (4" EMBED)
#5 CONT @
4 LOC SHOWN
EXIST TOF
VERIFY
6"
GEOTECH APPROVED STIFF SILT SOILS
OR ENGINEERED FILL (REF S-001)
NORTH
(ACTUAL)
NORTH
(REFERENCE)
ISSUES
SHEET NUMBER
SHEET TITLE
A
2 3
1 2 3
4 5
4 5
A
TSP, Inc.
PROJECT
NOT
FO
R
CONSTR
UCTI
ON
600 Kansas City St.
Rapid City, SD 57701
(605) 343-6102 www.teamtsp.com
C C
B B
D D
© TSP, Inc. 2017
ISSUE DATE
CHECKED BY
DRAWN BY
PROJECT #
LI
ST
ED
D
R
AW
IN
G
S
SC
AL
E(
S) U
N
LE
SS
R
ED
U
C
ED
F R
O M
O R
IG
IN
AL
x
F
O
RM
AT
CONSULTANTS
Architecture Engineering
Planning
KEY PLAN
EXTG. BLDG.
NEW ADDITION
4/ 7/
1:
:5
A
M I:\
_T S
P R ev it
Lo ca l\0
D ak ot a P la in s
K yl e C lin ic
S
_W ei er sA
R .r vt
FOUNDATION & FIRST
FLOOR FRAMING PLAN
& DETAILS
S-101
0%
D
ES
IG
N
D O
C U
M
EN
TS
Kyle, South Dakota
KYLE CLINIC HEALTH
CENTER ADDITION -
IHS
DAKOTA PLAINS
ARW04/07/2017
CSH03161153
SCALE: 1/8" = 1'-0"
A3
FIRST LEVEL FRAMING PLAN
SCALE: 1/8" = 1'-0"
A1
FOUNDATION PLAN/CRAWLSPACE
SCALE: 3/4" = 1'-0"
B5
TYP FOOTING & FOUNDATION WALL CORNER DETAILS
S033-01
SCALE: 3/4" = 1'-0"
D2
STOOP DETAIL
SCALE: 3/4" = 1'-0"
A5
EXTERIOR FOUNDATION DETAIL
SCALE: 3/4" = 1'-0"
D4
COLUMN/PIER DETAIL
S033-30
SCALE: 3/4" = 1'-0"
D1
FOUNDATION DOWEL DETAIL
S033-62
SCALE: 3/4" = 1'-0"
D3
FLR JST BRG @ EXIST/NEW FND
CC
BB
AA
1.7
1.7
FI
EL
D
VE
R
IF
Y
EX
IS
T
ST
EE
L
R O
O F
JO
IS
TS
'-0
"O C
FIELD VERIFY
EXIST STEEL ROOF JOISTS @ 5'-0"OC
S
PA
'-0
"(M
AX
5' -0
" 11 S
PA
'-0
"(M
AX
5' -0
W
X1
TO
S=
W
X1
TO
S=
W
X2
TO
S=
W
X1
TO
S=
12K1
12K1
12K1
12K1
12K1
12K1
10K1