This document is a Submittal List for the FILA Fan Coil Unit Repairs project being executed by the National Park Service (NPS) - Denver Service Center (DSC). The Submittal List outlines the required submittals and their review process for this construction project, including items such as the construction schedule, safety plan, quality control plan, product data, shop drawings, and various other documents across multiple specification sections.

The related federal contract opportunity is a Solicitation for the Fan Coil Repairs project at the First Ladies National Historic Site (FILA) in Canton, Ohio. The project has an estimated value between $250,000 and $500,000 and will be awarded as a firm-fixed price contract. The work consists of repairing multiple fan coil units throughout the six-story building. The project is set aside 100% for Total Small Businesses under NAICS code 238220 with a $19 million size standard. The solicitation will be issued as an Invitation for Bid (IFB), and a site visit is required. Interested offerors must have a Unique Entity Identifier (UEI) number and be registered and active in the System for Award Management (SAM) prior to the solicitation closing date.

View the file

Other files for this federal contract opportunity

Other files attached to Fan Coil Repairs, newest first.
File Type Posted
Questions_and_Answers_0001.pdf PDF
Sol_140P6424B0007_Amd_0001.pdf PDF
Attachment_-_Drawings-Pictures.pdf PDF
Attachment_-_Addendum_to_Specifications.pdf PDF
Attachment_-_Limitations_on_Subcontracting_Report.xlsx XLSX spreadsheet
Sol_140P6424B0007.pdf PDF
Attachment_-_Construction_Contract_Admin.pdf PDF
Attachment_-_Notice_to_Contractors.pdf PDF
Specifications_-_Fan_Coil_Repairs.pdf PDF
Bid_Schedule_-_Fan_Coil_Repairs.pdf PDF
Wage_Determination_-_Stark_Co.pdf PDF
Bid_Schedule_-_Fan_Coil_Repairs.xlsx XLSX spreadsheet
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FILA Fan Coil Replacement Submittal List National Park Service (NPS) - Denver Service Center (DSC) | 1-27-21

SUBMITTAL LIST ACTION SUBMITTAL

REVIEW ESTIMATE

Park Acronym/Project Management Information System (PMIS) Number: (Complete this portion for Architect / Engineer (A/E) Project Title: FILA Fan Coil Unit Repairs construction service task order negotiation.)

SUBMITTAL REQUIREMENTS ARCHITECT / ENGINEER REVIEW TIME

(Indicate with X) (Indicate in whole or partial hours.)

INFORMATIONAL ACTION

SP

EC

IF

IC

AT

IO

N S

EC

TI

O N

PA

R

AG

R

AP

H

N U

M

BE

R

DESCRIPTION

C

ER

TI

FI

C

AT

IO

N

S O

R

LA

BO

R

AT

O R

Y

TE

ST

S

R

EP

O R

TS

O

R C

AL

C

U

LA

TI

O

N S

O R

P

LA

N

M

AN

U

FA

C

TU

R

ER

D

AT

A

AN

D

IN

ST

R

U C

TI

O

N S

O

TH

ER

SA

M

PL

ES

SH

O

P D

R

AW

IN

G

S

M

AN

U

FA

C

TU

R

ER

D

AT

A

AN

D

IN

ST

R

U C

TI

O

N S

O

TH

ER

AR

C

H

IT

EC

T

C

IV

IL

E

N G

IN

EE

R

ST

R

U C

TU

R

AL

E

N G

IN

EE

R

M

EC

H

AN

IC

AL

E N

G

IN

EE

R

EL

EC

TR

IC

AL

E

N G

IN

EE

R

PR

O

JE

C

T M

AN

AG

ER

C

O R

D

IN

AT

IO

N

LA

N

D

SC

AP

E

AR

C

H

IT

EC

T

Division 1 Submittals 01 10 00 Preconstruction Conference Submittals

9.1.C.1 Letter Designating Project Superintendent 9.1.C.2 Construction Schedule 9.1.C.3 Schedule of Values 9.1.C.4 Accident Prevention (Safety) Plan (APP) 9.1.C.5 Subcontractors List 9.1.C.6 Subcontractor Certification Compliance 9.1.C.7 Quality Control Plan 9.1.C.8 Waste Management Plan 9.1.C.9 Indoor Air Quality (IAQ) Management Plan

9.1.C.10 Contractors Commissioning Plan 9.1.C.11 Historic Preservation Treatment Plan 9.1.C.12 List of Required Construction Permits

02 41 19 Selective Demolition Submittals 1.5.A Proposed Protection Measures X 1.5.B Schedule of Selective Demolition Activities X 1.5.C Predemolition Photographs or Video X 1.5.D Warranties Information X

08 31 13 Access Doors and Frames Product Data X Samples X Product Schedule X

230519 Meters and Gauges for HVAC Piping 1.2A Product Data X 1.2B Shop Drawings X 1.3A Product Certificates X

258437

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 1 of 3

SUBMITTAL LIST ACTION SUBMITTAL

REVIEW ESTIMATE

Park Acronym/Project Management Information System (PMIS) Number: (Complete this portion for Architect / Engineer (A/E) Project Title: FILA Fan Coil Unit Repairs construction service task order negotiation.)

SUBMITTAL REQUIREMENTS ARCHITECT / ENGINEER REVIEW TIME

(Indicate with X) (Indicate in whole or partial hours.)

INFORMATIONAL ACTION

SP

EC

IF

IC

AT

IO

N S

EC

TI

O N

PA

R

AG

R

AP

H

N U

M

BE

R

DESCRIPTION

C

ER

TI

FI

C

AT

IO

N

S

R

AT

O R

Y

TE

ST

S

R

EP

O R

TS

O

R C

AL

C

U

LA

TI

O

N S

O R

P

LA

N

M

AN

U

FA

C

TU

R

ER

D

AT

A

AN

D

IN

ST

R

U C

TI

O

N S

O

TH

ER

SA

M

PL

ES

SH

O

P D

R

AW

IN

G

S

M

AN

U

FA

C

TU

R

ER

D

AT

A

AN

D

IN

ST

R

U C

TI

O

N S

O

TH

ER

AR

C

H

IT

EC

T

C

IV

IL

E

N G

IN

EE

R

ST

R

U C

TU

R

AL

E

N G

IN

EE

R

M

EC

H

AN

IC

AL

E N

G

IN

EE

R

EL

EC

TR

IC

AL

E

N G

IN

EE

R

PR

O

JE

C

T M

AN

O R

D

IN

AT

IO

N

LA

N

D

SC

AP

E

AR

C

H

IT

EC

T

258437

230523 General Valves for HVAC Piping 1.2A Product Data X

230548 Vibration and Seismic Controls for HVAC 1.2A Product Data X 1.2B Shop Drawings X 1.3A Coordination Drawings X 1.3B Welding Certificates X 1.3C Field Quality Control Reports X

230553 Identification for HVAC Piping and Equipment 1.2A Product Data X 1.2B Samples X 1.3C Equipment Label Schedule X

230593 Testing, Adjusting, and Balancing for HVAC 1.3A Qualification Data X 1.3B Contract Documents Examination Report X 1.3C Strategies and Procedures Plan X 1.3D System Readiness Checklist X 1.3E Examination Report X 1.3F Certified TAB Report X 1.3G Stample Report Forms X 1.3H Instrumentation Calibration Reports X

230719 HVAC Piping Insulation 1.2A Product Data X 1.2B Sustainable Design Submittals X 1.2C Shop Drawings X 1.2D Samples X 1.3A Qualification Data X 1.2B Material Test Reports X 1.3C Field Quality Control Reports X

232113 Hydronic Piping 1.2A Product Data X 1.2B Sustainable Design Submittals X 1.2C Delegated Design Submittal X 1.3A Coordination Drawings X

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 2 of 3

SUBMITTAL LIST ACTION SUBMITTAL

REVIEW ESTIMATE

Park Acronym/Project Management Information System (PMIS) Number: (Complete this portion for Architect / Engineer (A/E) Project Title: FILA Fan Coil Unit Repairs construction service task order negotiation.)

SUBMITTAL REQUIREMENTS ARCHITECT / ENGINEER REVIEW TIME

(Indicate with X) (Indicate in whole or partial hours.)

INFORMATIONAL ACTION

SP

EC

IF

IC

AT

IO

N S

EC

TI

O N

PA

R

AG

R

AP

H

N U

M

BE

R

DESCRIPTION

C

ER

TI

FI

C

AT

IO

N

S

R

AT

O R

Y

TE

ST

S

R

EP

O R

TS

O

R C

AL

C

U

LA

TI

O

N S

O R

P

LA

N

M

AN

U

FA

C

TU

R

ER

D

AT

A

AN

D

IN

ST

R

U C

TI

O

N S

O

TH

ER

SA

M

PL

ES

SH

O

P D

R

AW

IN

G

S

M

AN

U

FA

C

TU

R

ER

D

AT

A

AN

D

IN

ST

R

U C

TI

O

N S

O

TH

ER

AR

C

H

IT

EC

T

C

IV

IL

E

N G

IN

EE

R

ST

R

U C

TU

R

AL

E

N G

IN

EE

R

M

EC

H

AN

IC

AL

E N

G

IN

EE

R

EL

EC

TR

IC

AL

E

N G

IN

EE

R

PR

O

JE

C

T M

AN

O R

D

IN

AT

IO

N

LA

N

D

SC

AP

E

AR

C

H

IT

EC

T

258437

1.3B Qualification Data X 232116 Hydronic Piping Specialties

1.2A Product Data X

Total: 0 0 0 0 0 0 0

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 3 of 3

Template

File details come from the government source that posted it. Updated .