ATTACHMENT - II - 610-15-105 Improve Security - Drawings.pdf
PDF 33 MB Posted
- Attached to
- Z1DA--Improve Security All Bldgs 610-15-105 Federal contract opportunity
- Solicitation number
- 36C25020B0071
About this file
This document provides details for a federal contract solicitation for improving security at all buildings of the Northern Indiana HealthCare System VA Medical Center. The solicitation number is 36C25020B0071 and will be posted on August 17, 2020 on SAM.gov for improving security across all buildings under project number 610-15-105. The opportunity is set aside only for verified Service-Disabled Veteran-Owned Small Businesses under the relevant NAICS code of 236210 with a size standard of $16.5 million. To be eligible, offerors must be registered and verified on VIP.vetbiz.va.gov and SAM.gov. The project magnitude is between $500,000 to $1 million and work must be completed within 180 days of receiving the notice to proceed. Performance and payment bonds will be required along with the winning bidder performing at least 25% of the construction work. A site visit will be scheduled upon the solicitation being posted and questions will only be addressed after proposal submission through a request for information process.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25020B0071 0002.docx | DOCX document | |
| RFI 7.pdf | ||
| RFI 4.pdf | ||
| RFI 2.pdf | ||
| RFI 6.pdf | ||
| RFI 5.pdf | ||
| RFI 1.pdf | ||
| 36C25020B0071 0001.docx | DOCX document | |
| RFI 3.pdf | ||
| ATTACHMENT - III - Contractor EMR Certification Form.docx | DOCX document | |
| ATTACHMENT - V - Site Visit Letter of Instruction For Potential Site Visit Attendees.docx | DOCX document | |
| 36C25020B0071.docx | DOCX document | |
| ATTACHMENT - I - 610-15-105 Improve Security - Specifications.pdf | ||
| ATTACHMENT - VI - Wage Determination IN20200002 7-24-2020.pdf | ||
| ATTACHMENT - IV - RFI Form Solicitaton.docx | DOCX document |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
BID DOCUMENTS - REVISED 01/14/2020
BID DOCUMENTS 12/30/2019
95% CONSTRUCTION DOCUMENTS 10/15/2019
65% DESIGN DEVELOPMENT 08/13/2019
35% SCHEMATIC DESIGN 01/14/2018
BID DOCUMENTS - REVISED 03/20/2020
C U s e rs \e b ro w n
\D o c u m e n ts
\1 .1
.0
M a ri o n V
A S e c u ri ty
I m p ro v e m e n ts e b ro w n
M
S K
.r v t
/1
/2
:4
:0
P
M
GI000
COVER SHEET MARION VA SECURITY
IMPROVEMENTS
1700 E 38TH ST MARION IN 46953
610-15-105
15, 16, 17, 124, 127, 138, 172, 174, 185
JACOB MORRICAL - CHIEF
ENGINEER 12/30/2019 JLG ELB
BID DOCUMENTS
FULLY SPRINKLERED
NORTHERN INDIANA HCS
1700 E 38TH ST MARION IN 46953
BID DOCUMENTS
MARION VA SECURITY IMPROVEMENTS
610-15-105
SHEET LIST
SHEET
NUMBER SHEET NAME
GENERAL
GI000 COVER SHEET
ARCHITECTURAL
AS001 ARCHITECTURAL SYMBOLS AND ABBREVIATIONS
AS002 OVERALL CAMPUS PLAN
15AS101 B-15 FIRST FLOOR ARCHITECTURAL PLAN
15AS102 B-15 SECOND FLOOR ARCHITECTURAL PLAN
16AS101 B-16 FIRST FLOOR ARCHITECTURAL PLAN
16AS102 B-16 SECOND FLOOR ARCHITECTURAL PLAN
16AS103 B-16 THIRD FLOOR ARCHITECTURAL PLAN
17AS101 B-17 FIRST FLOOR ARCHITECTURAL PLAN
17AS102 B-17 SECOND FLOOR ARCHITECTURAL PLAN
124AS101 B-124 FIRST FLOOR ARCHITECTURAL PLAN
124AS102 B-124 SECOND FLOOR ARCHITECTURAL PLAN
124AS103 B-124 THIRD FLOOR & PENTHOUSE ARCHITECTURAL PLAN
127AS101 B-127 FIRST FLOOR ARCHITECTURAL PLAN
138AS100 B-138 BASEMENT FLOOR ARCHITECTURAL PLAN
138AS101 B-138 FIRST FLOOR ARCHITECTURAL PLAN
138AS102 B-138 SECOND FLOOR ARCHITECTURAL PLAN
138AS103 B-138 THIRD FLOOR ARCHITECTURAL PLAN
138AS104 B-138 FOURTH FLOOR ARCHITECTURAL PLAN
170AS101 B-170 FIRST FLOOR ARCHITECTURAL PLAN
172AS100 B-172 BASEMENT FLOOR ARCHITECTURAL PLAN
172AS101 B-172 FIRST FLOOR ARCHITECTURAL PLAN
172AS102 B-172 SECOND FLOOR ARCHITECTURAL PLAN
174AS101 B-174 FIRST FLOOR ARCHITECTURAL PLAN
185AS101 B-185 FIRST FLOOR ARCHITECTURAL PLAN
185AS102 B-185 SECOND FLOOR ARCHITECTURAL PLAN
TECHNOLOGY
T001 LEGENDS, ABBREVIATIONS & INDEX OF DRAWINGS
T002 SECURITY DETAILS
T003 TECHNOLOGY DETAILS
T100 FIBER BACKBONE RISER DIAGRAM
15T101 BLDG 15 - FIRST FLOOR TECHNOLOGY PLAN
15T102 BLDG 15 - SECOND FLOOR TECHNOLOGY PLAN
16T101 BLDG 16 - FIRST FLOOR TECHNOLOGY PLAN
16T102 BLDG 16 - SECOND FLOOR TECHNOLOGY PLAN
16T103 BLDG 16 - THIRD FLOOR TECHNOLOGY PLAN
17T101 BLDG 17 - FIRST FLOOR TECHNOLOGY PLAN
17T102 BLDG 17 - SECOND FLOOR TECHNOLOGY PLAN
124T101 BLDG 124 - FIRST FLOOR TECHNOLOGY PLAN
124T102 BLDG 124 - SECOND FLOOR TECHNOLOGY PLAN
124T103 BLDG 124 - THIRD FLOOR TECHNOLOGY PLAN
124T201 ENLARGED PLANS
124T202 ENLARGED TR 328
127T101 BLDG 127 - FIRST FLOOR TECHNOLOGY PLAN
127T200 ENLARGED FIBER DISTRIBUTION ROOM
138T100 BLDG 138 - BASEMENT PLAN
138T101 BLDG 138 - FIRST FLOOR TECHNOLOGY PLAN
138T102 BLDG 138 - SECOND FLOOR TECHNOLOGY PLAN
138T103 BLDG 138 - THIRD FLOOR TECHNOLOGY PLAN
138T104 BLDG 138 - FOURTH FLOOR TECHNOLOGY PLAN
138T201 ENLARGED PLANS
138T205 ENLARGED PLANS
170T101 BLDG 170 - FIRST FLOOR TECHNOLOGY PLAN
172T100 BLDG 172 - BASEMENT / TUNNEL PLAN
172T101 BLDG 172 - FIRST FLOOR TECHNOLOGY PLAN
172T102 BLDG 172 - SECOND FLOOR TECHNOLOGY PLAN
172T201 ENLARGED PLANS
174T100 BLDG 174 - BASEMENT
174T101 BLDG 174 - FIRST FLOOR TECHNOLOGY PLAN
174T200 ENLARGED TR 111B
185T101 BLDG 185 - FIRST FLOOR TECHNOLOGY PLAN
185T102 BLDG 185 - SECOND FLOOR TECHNOLOGY PLAN
185T201 ENLARGED PLANS
ELECTRICAL
E001 LEGENDS, ABBREVIATIONS & INDEX OF DRAWINGS
E002 ELECTRICAL DETAILS
15E101 BLDG 15 - FIRST FLOOR ELECTRICAL PLAN
16E101 BLDG 16 - FIRST FLOOR ELECTRICAL PLAN
124E101 BLDG 124 - FIRST FLOOR ELECTRICAL PLAN
124E103 BLDG 124 THIRD FLOOR ELECTRICAL PLAN
127E101 BLDG 127 - FIRST FLOOR ELECTRICAL PLAN
138E100 BLDG 138 - BASEMENT ELECTRICAL PLAN
172E100 BLDG 172 - BASEMENT / TUNNEL PLAN
185E101 BLDG 185 - FIRST FLOOR ELECTRICAL PLAN
HEAPY ENGINEERING
MECHANICAL,
ELECTRICAL &
PLUMBING
NORTHERN INDIANA HCS
1700 E 38th St.
Marion, IN 46953
OWNER
GUIDON DESIGN INC.
ARCHITECT
1400 W Dorothy Lane Dayton, OH 45409
AREA MAP
VICINITY MAP
N
N
PROJECT LOCATION
PROJECT LOCATION
1221 N. Pennsylvania St.
Indianapolis, IN 46202
Contact:
Andrew Mercker
COR
Contact:
James Krile Senior Technology Engineer
Contact:
James Gooden Project Manager p: 317.800.6388 x 145 e: jgooden@guidondesign.com p: 765.674.3321 x 73459 e: andrew.mercker@va.gov p: 937.224.0861 e:jdkrile@heapy.com
Revisions: Date:
ARCHITECTURAL ABBREVIATIONS
SECTION REFERENCE
DRAWING NUMBER
SHEET
LOCATION
DRAWING NUMBER
SHEET
LOCATION
DETAIL REFERENCE
OBJECT
REFERENCED
OBJECT
REFERENCED
X
XXXX
X
XXXX
SCALE: ??
VIEW TITLE
N
NORTH ARROW
EXTENT OF REVISION
REVISION SET
PROJECT BOUNDARY
BEYOND PROJECT BOUNDARY, NIC
DETAIL/DRAWING SCALE
TITLE OF DETAIL/DRAWING
DETAIL/DRAWING NUMBER
SHEET NUMBER
A/C AIR CONDITION
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ABC AGGREGATE BASE COURSE
AC ASBESTOS CEMENT OR ASPHALTIC CONCRETE
ACS DR ACCESS DOOR
ACS FLR ACCESS FLOOR
ACS PNL ACCESS PANEL
ACST ACOUSTIC
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADC AUTOMATIC DOOR CLOSER
ADDL ADDITIONAL
ADDN ADDITION
ADH ADHESIVE
ADJ ADJACENT, ADJOINING, OR ADJUSTABLE
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHJ AUTHORITY HAVING JURISDICTION
AHR ANCHOR
AHU AIR HANDLING UNIT
AIA AMERICAN INSTITUTE OF ARCHITECTS
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
ALUM ALUMINUM
AMP AMPERE
AMT AMOUNT
ANOD ANODIZE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
ANT ANTENNA
APPD APPROVED
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASB ASBESTOS
ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTION
ASKLR AUTOMATIC SPRINKLER
ASPH ASPHALT
ASSN ASSOCIATION
ATCH ATTACHMENT
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AVG AVERAGE
AW ACID WASTE
AWI ARCHITECTURAL WOODWORKING INSTITUTE
AWS AMERICAN WELDING SOCIETY
AWT ACOUSTICAL WALL TREATMENT
B PL BASE PLATE
BALC BALCONY
BAT BATTEN
BB BULLETIN BOARD
BD BOARD
BEV BEVEL
BI FLD DR BIFOLDING DOORS
BITUM BITUMINOUS
BKG BACKING
BLD BUILD
BLDG BUILDING
BLKG BLOCKING
BLKT BLANKET
BM BEAM OR BENCHMARK
BOT BOTTOM
BRCG BRACING
BRDG BRIDGING
BRG BEARING
BRKT BRACKET
BRZ BRONZE
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C CELSIUS CHANNEL OR CHANNEL CELSIUS
C CONC CAST CONCRETE
C TO C CENTER TO CENTER
CAB CABINET
CB CORNER BEAD
CBB CEMENTITIOUS (BACKER) BOARD
CC CUBIC CENTIMETER
CCTV CLOSED CIRCUIT TELEVISION
CCW COUNTERCLOCKWISE
CEM CEMENT
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CGSFU CERAMIC GLAZED STRUCTURAL FACING UNITS
CH BD CHALKBOARD
CHEM CHEMICAL
CHFR CHAMFER
CI CAST IRON
CIP CAST-IN-PLACE
CIR CIRCLE
CIRC CIRCULAR
CJ CONSTRUCTION JOINT OR CONTROL JOINT
CL CENTER LINE
CLDG CLADDING
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CNR CORNER
CNTR COUNTER
CO CARBON MONOXIDE, CLEANOUT
CO₂ CARBON DIOXIDE
COL COLUMN
COM COMMON
COMB COMBINATION, COMBINED
COMM COMMUNICATION
COMP COMPONENT
CONC CONCRETE
COND CONDENSER OR CONDITION
CONF CONFERENCE
CONN CONNECT
CONSTR CONSTRUCTION
CONT CONTINUE
CONTR CONTRACTOR
COORD COORDINATE
CORR CORRIDOR
CPM CRITICAL PATH METHOD
CPRS COMPRESSIBLE
CPT CARPET
CRS COLD ROLLED STEEL
CS CAST CONCRETE STONE
CSB CONCRETE SPLASH BLOCK
CSG CASING
CSK COUNTER SUNK
CSMT CASEMENT
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTG COATING
CTR CENTER
CTRL CONTROL
CTV CABLE TELEVISION
CU COPPER C
CU FT CUBIC FEET
CU IN CUBIC INCH
CU YD CUBIC YARD
CURT CURTAIN
CYL CYLINDER
CYL L CYLINDER LOCK
N NORTH
NA NOT APPLICABLE
NAT NATURAL
NATL NATIONAL
NC NOISE CRITERIA
NCOMBL NONCOMBUSTIBLE
NEG NEGATIVE
NEUT NEUTRAL
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NR NOISE REDUCTION
NRC NOISE REDUCTION COEFFICIENT
NRP NONREMOVABLE
NS NARROW STILE
NUM NUMERAL
O/O OUT TO OUT
O OXYGEN
OA OUTSIDE AIR OR OVERALL
OC ON CENTER
OCC OCCUPY
OCT OCTAGON
OD OUTSIDE DIAMETER OR OUTSIDE DIMENSION
OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED
OFD OVERFLOW DRAIN
OFF OFFICE
OF/OI OWNER FURNISHED/OWNER INSTALLED
OH OVERHANG
OH DR OVERHEAD (COILING) DOOR
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
OPT OPTIONAL
OR OPERATING ROOM OR OUTSIDE RADIUS
ORD ORDNANCE OR OVERFLOW ROOF DRAIN
ORG ORGANIC
ORIG ORIGINAL
ORN ORNAMENTAL
OUT OUTLET
OZ OUNCE
PAR PARALLEL OR PARAPET
PART PARTIAL
PAT PATTERN
PB PUSHBUTTON
PBD PARTICLEBOARD
PC PIECE, POLYCARBONATE OR PORTLAND CEMENT
PCC PRECAST CONCRETE
PCCP CONCRETE PAVEMENT
PCD PAPER CUP DISPENSER
PCF POUNDS PER CUBIC FOOT
PCP PORTLAND CEMENT PLASTER
PED PEDESTAL
PEN PENETRATE
PEND PENDANT
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PGBD PEGBOARD
PHS PHILLIPS HEAD SCREW
PKG PACKAGE
PL PLATE, PROPERTY LINE
PLAM PLASTIC LAMINATE
PLAS PLASTER OR PLASTIC
PLBG PLUMBING
PLYWD PLYWOOD
PMTL PAINTED METAL
PNEU PNEUMATIC
PNL PANEL
POLY POLYETHYLENE (PLASTIC)
PR PAIR
PRCST PRECAST
PREFAB PREFABRICATE
PREFIN PREFINISH
PRELIM PRELIMINARY
PREP PREPARATION
PRESS PRESSURE
PREV PREVIOUS
PRKG PARKING
PRMLD PREMOLDED
PROJ PROJECT
PROP PROPERTY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT, PNEUMATIC TUBE, OR PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTN PARTITION
PVC POLYVINYL CHLORIDE (PLASTIC)
PVG PAVING
PWR POWER
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QRY QUARRY
QT QUARRY TILE
QTB QUARRY TILE BASE
QTF QUARRY TILE FLOOR
QTR QUARTER
QTY QUANTITY
QUAD QUADRANT
QUAL QUALITY
R RADIUS OR RISER
RA RETURN AIR
RAD RADIATOR
RB RESILIENT BASE OR RUBBER BASE
RB HK ROBE HOOK
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RCP REFLECTED CEILING PLAN
RCVR RECEIVER
RD ROAD OR ROOF DRAIN
REC RECESSED
RECD RECEIVED
RECPT RECEPTACLE
RECT RECTANGLE
REF REFERENCE OR REFRIGERATOR
REFR REFRACTORY REFRIGERATION OR REFRIGERATION
REFRACTORY
REG REGISTER
REINF REINFORCE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
RET RETURN
REV REVISION
RF RADIO FREQUENCY
RFG ROOFING
RFI REQUEST FOR INFORMATION
RFP REQUEST FOR PROPOSAL
RH RIGHT HAND
RHMS ROUND HEAD MACHINE SCREW
RHR RIGHT HAND REVERSE
RHWS ROUND HEAD WOOD SCREW
RL ROOF LEADER
RLG RAILING
RM ROOM
RND ROUND
RO ROUGH OPENING
ROW RIGHT OF WAY
RPM REVOLUTIONS PER MINUTE
RS ROUGH SAWN
RT RIGHT
RV ROOF VENT
RVS REVERSE
RWD REDWOOD
RWL RAIN WATER LEADER
W/ WITH
W/O WITHOUT
WARR WARRANTY
WBL WOOD BLOCKING
WC WALL COVERING OR WATER CLOSET
WC WL HNG WATER CLOSET, WALL HUNG
WCHR WATER CHILLER
WCL WL MTD WATER COOLER, WALL HUNG
WD WOOD
WDW WINDOW
WF WIDE FLANGE
WFAB WALL FABRIC
WFR WOOD FRAME
WFS WOOD FURRING STRIPS
WH WATER HEATER
WHSE WAREHOUSE
WLD WELDED
WM WIRE MESH
WP WATERPROOFING
WPD WATER PRESSURE DROP
WPM WATERPROOF MEMBRANE
WR WEATHER RESISTANT
WS WEATHERSTRIP
WSCT WAINSCOT
WT WEIGHT
WWF WELDED WIRE FABRIC
X BRACE CROSS BRACE
XPS EXTRUDED POLYSTYRENE BOARD (INSULATION)
YD YARD
YR YEAR
GENERAL CONSTRUCTION NOTES
THE CONTRACT DOCUMENT DRAWINGS HAVE BEEN PREPARED USING REVIT®
SOFTWARE IN A MICROSOFT WINDOWS ENVIRONMENT. A BUILDING INFORMATION
MODEL (BIM) HAS BEEN DEVELOPED FOR DESIGN COMMUNICATION. THE MODEL
DOES NOT CONTAIN COMPLETE INFORMATION FOR USE IN COST ESTIMATING,
SYSTEMS PERFORMANCE, COORDINATION, SCHEDULING, OR FACILITIES
MANAGEMENT.
THE CONTRACT DOCUMENT DRAWINGS HAVE BEEN PREPARED USING THE
CONSTRUCTION SPECIFICATIONS INSTITUTE'S UNIFORM DRAWING SYSTEM AND THE
NATIONAL CAD STANDARD AS GUIDES.
DISCREPANCIES IN THE CONTRACT DOCUMENTS SHALL BE IMMEDIATELY BROUGHT
TO THE ATTENTION OF THE ARCHITECT AND OWNER’S REPRESENTATIVE/COR.
CONTRACTOR SHALL PROVIDE THE HIGHER GRADE OF QUALITY AND/OR GREATER
QUANTITY OF WORK WHEN BIDDING IF A CLARIFICATION CAN NOT BE OBTAINED BY
THE BID DUE DATE.
CONTRACTOR IS RESPONSIBLE FOR COORDINATING SCOPE OF WORK WITH OWNER’S
REPRESENTATIVE/COR AND VARIOUS FACILITY PERSONNEL INVOLVED WITH UTILITY
SHUT DOWN, INFECTION CONTROLS, OCCUPANT/EMPLOYEE SAFETY, ACCESS
CONTROL, ETC.
ANY INDICATION OF PROJECT LIMITS OR BOUNDARY OF DEMARCATION ARE SHOWN
FOR THE CONVENIENCE OF THE CONTRACTOR, THE FULL SCOPE OF THE PROJECT
LIMIT OF BOUNDARY REQUIRES COORDINATION WITH THE DESIGN SCOPE OF WORK
AND ACCESS TO EXISTING UTILITIES FOR TIE IN.
DRAWINGS ARE PREPARED FROM FIELD VERIFICATION, EXISTING FACILITY DRAWING
BASE FILES, AND USING DIMENSIONS, CONFIGURATIONS AND DETAILS OF SPECIFIC
MANUFACTURERS AS A BASIS OF DESIGN. CONTRACTOR IS RESPONSIBLE FOR
VERIFICATION OF ACTUAL DIMENSIONS, THE COORDINATION OF THE DETAILS WITH
THE PRODUCTS WHICH ARE PROVIDED PER THE SCOPE OF THE SPECIFICATIONS AND
THE SURROUNDING CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS,
ROUGH-IN DIMENSIONS, CONNECTIONS, AND OVERALL INSTALLATION
REQUIREMENTS.
CONTRACTOR IS RESPONSIBLE FOR THE COMPLETION OF THE ENTIRE SCOPE OF
WORK OUTLINED IN THE CONTRACT DOCUMENTS. CONTRACTOR IS RESPONSIBLE
FOR THE COORDINATION OF ALL SUB-CONTRACTORS AND THE SCOPE OF WORK
THEY PROVIDE. SUB-CONTRACTORS ARE RESPONSIBLE FOR THEIR FULL SCOPE OF
WORK WITHIN THE CONTRACT DOCUMENTS, TRADES ARE NOT SEGMENTED TO ONLY
CERTAIN SHEETS AND SPECIFICATIONS, CROSS COORDINATION IS REQUIRED.
CONTRACTOR AND SUB-CONTRACTORS ARE BOTH RESPONSIBLE FOR
UNDERSTANDING INFORMATION OUTLINED IN THE SPECIFICATIONS, KEY NOTES,
GENERAL NOTES, LEGEND, CODES, ETC., PROVIDED IN THE CONTRACT DOCUMENTS.
CONTRACTOR AND SUB-CONTRACTORS ARE BOTH RESPONSIBLE FOR PROVIDING
AND MAINTAINING SMOKE/FIRE RATINGS OF NEW CONSTRUCTION AND EXISTING
CONSTRUCTION AS INDICATED ON DRAWINGS. THIS INCLUDES PATCHING
PENETRATIONS IN SHAFTS, WALLS, SLABS AND ROOF. ONLY U.L. APPROVED
METHODS, MATERIALS AND INSTALLATION ARE ACCEPTABLE.
TECHNOLOGY AND ELECTRICAL DRAWINGS SHOW INFORMATION IN A DIAGRAMMATIC
FASHION WITHOUT DIMENSIONING. THE GENERAL CONTRACTOR IS TO COORDINATE
THE LOCATIONS OF ALL MECHANICAL, PLUMBING AND ELECTRICAL EQUIPMENT WITH
RESPECT TO THE ARCHITECTURAL AND STRUCTURAL DETAILING OF SHAFTS,
CHASES, CEILING CONSTRUCTION, ETC.
CONTRACTOR IS RESPONSIBLE FOR VERIFYING DIMENSIONS IDENTIFIED AND NOT
IDENTIFIED IN THE CONTRACT DOCUMENTS WITH THE EXISTING AND NEW
CONSTRUCTION ELEMENTS. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION
BETWEEN THE CONTRACT DOCUMENTS, INSTALLED AND UNINSTALLED
CONSTRUCTION BEFORE THE ORDERING OF MATERIALS AND EQUIPMENT. NOTIFY
ARCHITECT AND OWNER’S REPRESENTATIVE/COR OF ANY DISCREPANCIES OR
MISSING DIMENSIONS.
DO NOT SCALE THE DRAWINGS. DRAWING SCALES AS INDICATED ARE FOR GENERAL
ORIENTATION AND CONTEXT ONLY.
THE TERM "ALIGN" MEANS TO INSTALL DIFFERENT/SIMILAR COMPONENTS OF
CONSTRUCTION TO PROVIDE A FLUSH FINISH SURFACE.
ALL DIMENSIONS INDICATED ARE TO FACE OF EXISTING MEMBERS, FACE OF NEW
STRUCTURAL MEMBERS, FACE OF NEW MASONRY, FACE OF NEW STUDS OR COLUMN
GRID LINES UNLESS NOTED OTHERWISE.
CONTRACTOR TO PROVIDE WORK WHERE DETAILS AND NOTES ARE IDENTIFIED AS
“TYPICAL” OR “SIMILAR” EACH INSTANCE THAT IS THE SAME IN NATURE TO THE
DETAIL, AREA, OR ITEM REFERENCED.
PROVIDED WORK SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR.
CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF DELIVERY, MOUNTING,
INSTALLATION, NECESSARY BLOCKING AND ROUGH-IN.
INSTALLED WORK IS THE CONTRACTOR INSTALLING OWNER FURNISHED MATERIALS
AND EQUIPMENT. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF MATERIAL
DELIVERY, MOUNTING, INSTALLATION AND ROUGH IN.
FURNISHED WORK IS THE CONTRACTOR FURNISHING THE MATERIALS AND
EQUIPMENT TO THE OWNER. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF
DELIVERY AND ROUGH-IN.
ALL PROVIDED WORK SHALL BE WITH NEW MATERIALS UNLESS SPECIFICALLY CALLED
OUT AS SALVAGED OR RELOCATED WITHIN THE CONTRACT DOCUMENTS.
ALL PERSONS DIRECTLY OR INDIRECTLY ASSOCIATED WITH THE PROJECT SHALL BE
FAMILIAR WITH THE RULES AND REGULATIONS OF THE OCCUPATIONAL SAFETY AND
HEALTH ACT, AND IMPLEMENT THOSE RULES AS THEY APPLY TO THIS PROJECT.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL
UTILITY LINES. LOCATIONS SHOWN ARE APPROXIMATE. REPAIR ALL DAMAGE TO
UTILITY LINES CAUSED BY CONSTRUCTION OPERATIONS AT NO COST TO THE
OWNER.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TEMPORARY BRACING AND SHORING
REQUIRED DURING CONSTRUCTION.
CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ADJACENT CONSTRUCTION,
FINISHES, EQUIPMENT, AND TRAVEL ROUTE TO AND FROM THE CONSTRUCTION SITE.
ANY DAMAGE OR UNACCEPTABLE WEAR BY THE CONSTRUCTION TEAM SHALL BE
REPAIRED/REPLACED BY THE CONTRACTOR AT NO COST TO THE OWNER.
IN THE CASE OF CONFLICTS OR DISCREPANCIES WITHIN OR AMONG THE CONTRACT
DRAWINGS, THE BETTER QUALITY, MORE STRINGENT REQUIREMENTS OR GREATER
QUALITY OF WORK, AS DETERMINED BY THE COR, SHALL BE PROVIDED.
CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND COORDINATING HARDWARE,
ACCESS CONTROL AND AUTOMATIC OPERATORS ARE PROVIDED WITH COMPLETE
AND COMPATIBLE SYSTEMS REQUIRED FOR THEIR OPERATION. REFER TO DOOR
HARDWARE SCHEDULE, HARDWARE SPECIFICATIONS, AUTOMATIC OPERATOR
SPECIFICATIONS, ACCESS CONTROL SPECIFICATIONS AND ELECTRICAL DRAWINGS.
ABOVE CEILING WORK SHALL TAKE PLACE BETWEEN THE HOURS OF 5:00 PM AND
5:00 AM. IN AREAS THAT REQUIRE ABOVE CEILING WORK WHERE CEILINGS ARE TO
REMAIN, CEILING TILES SHALL BE REMOVED AND STORED IN A SAFE MANOR UNTIL
CEILING TILES CAN BE REINSTALLED. DAMAGED AND BROKEN CEILING TILES SHALL
BE REPLACED BY CONTRACTOR.
WORK REQUIRING VIBRATION OR LOAD NOISE SHALL TAKE PLACE BETWEEN THE
HOURS OF 5:00 PM AND 5:00 AM. EVERY EFFORT SHALL BE MADE TO KEEP NOISE AND
VIBRATION TO A MINIMUM
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
D DEPTH OR PENNY (NAIL)
D LABEL CLASS D DOOR
DAT DATUM
DB DECIBEL
DBL DOUBLE
DBL GLZ DOUBLE GLAZE
DC DIRECT CURRENT
DEG DEGREE
DEL DELETE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL DIAGRAM OR DIAGRAM DIAGONAL
DIFF DIFFERENCE OR DIFFUSER
DIM DIMENSION
DIR DIRECTION
DISP DISPENSER
DIST DISTANCE
DIV DIVIDE OR DIVISION
DL DEAD LOAD
DOC DOCUMENT
DOZ DOZEN
DN DOWN
DR DOOR, DRAIN, DRESSING ROOM, OR DRIVE
DS DOWNSPOUT
DSGN DESIGN
DW DISHWASHER
DWG DRAWING
DWTR DUMBWAITER
E EAST
EA EACH
EFF EFFICIENCY
EFS EXTERIOR FINISH SYSTEM
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRIC
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
ENGR ENGINEER
ENVIR ENVIRONMENT
EPA ENVIRONMENTAL PROTECTION AGENCY
EPDM ETHYLENE PROPYLENE DIENE MONOMER
EPO EMERGENCY POWER OFF
EPS EXPANDED POLYSTYRENE BOARD (INSULATION)
EQ EQUAL
EQL SP EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ERD EXISTING ROOF DRAIN
ESC ESCAPE OR ESCUTCHEON
ESCAL ESCALATOR
EST ESTIMATE
ETC AND SO FORTH OR ET CETERA
ETS EXPOSE TO STRUCTURE
EW EACH WAY
EWC ELECTRIC WATER COOLER
EWS EYE WASH STATION
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION OR EXPOSED
EXT EXTERIOR, EXTERNAL, OR EXTINGUISHER
F FAHRENHEIT OR FEMALE
FA FIRE ALARM
FAB FABRIC
FAC FACTOR
FACIL FACILITY
FAS FASCIA
FCO FLOOR CLEANOUT
FCTY FACTORY
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF&E FURNITURE, FIXTURE, AND EQUIPMENT
FH FLAT HEAD OR FLAT HEAD SCREWS
FHC FIRE HOSE CABINET
FHMS FLAT HEAD MACHINE SCREW
FHP FULL HEIGHT PARTITION
FHWS FLAT HEAD WOOD SCREW
FIG FIGURE
FIL FILLET
FIN FINISH
FIXT FIXTURE
FL FLOORLINE
FLASH FLASHING
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLR FLOOR
FLUOR FLUORESCENT
FM FACTORY MUTUAL
FM-G FACTORY MUTUAL GLOBAL
FO FINISHED OPENING
FOC FACE OF CONCRETE OR FACE OF CURB
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF SLAB OR FACE OF STUD
FOUNT FOUNTAIN
FOW FACE OF WALL
FP FIRE PROTECTION OR FIREPROOF
FPM FEET PER MINUTE
FPS FEET PER SECOND
FR FIRE RATING, FIRE RESISTANT, OR FRAME
FR SNK FLUSHING RIM SINK
FREQ FREQUENCY
FRMG FRAMING
FRP FIBER REINFORCED POLYESTER OR FIBERGLASS
REINFORCED PLASTIC
FRZ FREEZER
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET OR FOOT
FTG FOOTING
FURG FURRING
FURN FURNISH OR FURNITURE
FUT FUTURE
FWC FABRIC WALLCOVERING
GA GAGE OR GYPSUM ASSOCIATION
GAL GALLON
GALV GALVANIC OR GALVANIZED
GALV STL GALVANIZED STEEL
GB GRAB BAR
GC GENERAL CONTRACTOR
GD GUARD
GDR GUARD RAIL
GEN GENERAL OR GENERATOR
GFRC GLASS-FIBER-REINFORCED CONCRETE
GFRG GLASS-FIBER-REINFORCED GYPSUM
GFRP GLASS-FIBER-REINFORCED PLASTIC
GI GALVANIZED IRON
GL GLASS
GLU LAM GLUED LAMINATED WOOD
GR FL GROUND FLOOR
GRAN GRANITE
GRTG GRATING
GSB GYPSUM SHEATHING BOARD
GSM GALVANIZED SHEET METAL
GSU GLAZED STRUCTURAL UNIT
GT GROUT
GUAR GUARANTEE
GUT GUTTER
GYP GYPSUM
H HIGH
H PLAM HIGH PRESSURE PLASTIC LAMINATE
HAZ MAT HAZARDOUS MATERIALS
HB HOSE BIBB
HC HOLLOW CORE
HCWD HOLLOW CORE WOOD DOOR
HDBD HARDBOARD
HDNR HARDENER
HDO HIGH DENSITY OVERLAY
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HEX HEXAGON
HF HIGH FREQUENCY
HGR HANGER
HM HECTOMETER OR HOLLOW METAL
HMD HOLLOW METAL DOOR
HMDF HOLLOW METAL DOOR AND FRAME
HMF HOLLOW METAL FRAME
HNDRL HANDRAIL
HO HOLD OPEN
HORIZ HORIZONTAL
HOSP HOSPITAL
HP HIGH PRESSURE OR HORSEPOWER
HS HEAT-STRENGTHENED (GLASS) OR HIGH STRENGTH
HSKPG HOUSEKEEPING
HST HOIST
HT HEIGHT
HVAC HEATING, VENTILATING, AND AIR CONDITIONING
HVY HEAVY
HW HOT WATER
HYD HYDRANT
HYDR HYDRAULIC
I INTERSTATE (HIGHWAY) OR MOMENT OF INERTIA
IAQ INDOOR AIR QUALITY
IBC INTERNATIONAL BUILDING CODE
ID IDENTIFICATION, INSIDE DIAMETER
ID NO IDENTIFICATION NUMBER
ILLUM ILLUMINATION
INCL INCLUDED
IND INDEPENDENT OR INDUSTRIAL
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
INTERCOM INTERCOMMUNICATION
INTL INTERNATIONAL
IRMA INVERTED ROOF MEMBRANE ASSEMBLY
IWH INSTANTANEOUS WATER HEATER
JAN JANITOR
J-BOX JUNCTION BOX
JT JOINT
KD KILN DRIED OR KNOCKED DOWN
KIT KITCHEN
KO KNOCKOUT
KPL KICKPLATE
L ANGLE
LAB LABORATORY
LAD LADDER
LAM LAMINATE
LAM GL LAMINATED GLASS
LAU LAUNDRY
LAV LAVATORY
LBR LUMBER
LBS POUND
LD BRG LOAD-BEARING
LDR LEADER
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LH LEFT HAND
LHR LEFT HAND REVERSE OR LEFT HAND REVERSE
LATENT HEAT RATIO
LIB LIBRARY
LIN LINEAR
LINO LINOLEUM
LIQ LIQUID
LKR LOCKER
LKR RM LOCKER ROOM
LKWASH LOCKWASHER
LL LEAD LINED
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMST LIMESTONE
LNDSCP LANDSCAPE
LR LIVING ROOM
LRG LARGE
LRV LOUVERED ROOF VENT
LS LUMP SUM
LT LIGHT
LT GA LIGHT GAGE
LT WT LIGHTWEIGHT
LTG LIGHTING
LTNG LIGHTNING
LVD LOUVERED
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
LWIC LIGHTWEIGHT INSULATING CONCRETE
LYR LAYER
MACH MACHINE
MACH RM MACHINE ROOM
MAINT MAINTENANCE
MAN MANUAL
MATL MATERIAL
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MB MACHINE BOLT
MCB METAL CORNER BEAD
MD DECK
ME MECHANICAL ENGINEER
MEAS MEASURE
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MED MEDICAL MEDIUM OR MEDIUM MEDICAL
MEK METHYL ETHYL KETONE
MEL MELAMINE
MEMB MEMBRANE
MEMO MEMORANDUM
MEZZ MEZZANINE
MF MILL FINISH
MFD MANUFACTURED
MFG MANUFACTURING
MFR MANUFACTURER
MFR REC MANUFACTURER'S RECOMMENDATION
MGT MANAGEMENT
MH MANHOLE
MIC MICROPHONE
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM MINUTE OR MINUTE MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MIT MITER
MKR MARKER
ML METAL LATH
MLDG MOLDING (MOULDING)
MLWK MILLWORK
mm MILLIMETER
MO MASONRY OPENING OR MOTOR OPERATED
MOD MODEL, MODIFY OR MODULE
MOD BIT MODIFIED BITUMEN
MON MONITOR
MOPR MOP RACK
MR MOISTURE RESISTANT
MS MACHINE SCREW OR MOP SINK
MTD MOUNTED
MTG MOUNTING
MTL METAL
MULL MULLION
MW MICROWAVE
MWP MEMBRANE WATERPROOFING
ARCHITECTURAL SYMBOLS
X
X
XXXX
SHEET LOCATION
VIEW NUMBER
X X
X
SHEET LOCATION
VIEW NUMBER
XXXX
BUILDING SECTION REFERENCE
DRAWING NUMBER
SHEET LOCATION
BUILDING X
XXXX
X
XXXX
ELEVATION REFERENCES
NEW WALL
WALL TO BE
REMOVED
S3.A2
INDICATES STRUCTURAL MATERIAL
INDICATES NOMINAL STUD / BLOCK SIZE
INDICATES CONSTRUCTION
INDICATES TOP OF WALL CONDITION
REFER TO WALL LEGEND FOR MORE INFORMATION
EXISTING WALL TO
REMAIN
TEMPORARY IC
BARRIER WALL
CONSTRUCTION
ROOM
ROOM TAG
1 PLAN NOTE
ALTERNATE/BID DEDUCT ITEM
PT-1 FINISH INDICATION
A FRAME / WINDOW
T GLAZING
101 EQUIPMENT/FURNITURE TAG
NEW DOOR
EXISTING DOOR
DEMOLISHED DOOR
SA SUPPLY AIR
SALV SALVAGE
SAMP SAMPLE
SAN SANITARY
SAT SUSPENDED ACOUSTICAL TILE
SATC SUSPENDED ACOUSTICAL TILE CEILING
SB SPLASH BLOCK
SBS STYRENE BUTADIEN STYRENE
SBSTR SUBSTRATE
SC SHADING COEFFICIENT OR SOLID CORE
SCH SCHOOL
SCHED SCHEDULE
SCHEM SCHEMATIC
SCP SCUPPER
SCRN SCREEN
SCT STRUCTURAL CLAY TILE
SCWD SOLID CORE WOOD DOOR
SD SHOP DRAWINGS, SMOKE DETECTOR OR SOAP
DISPENSER
SDG SIDING
SECT SECTION
SEG SEGMENT
SEL SELECT
SEP SEPARATE
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGD SLIDING GLASS DOOR
SGL SINGLE
SHR SHOWER
SHR HD SHOWER HEAD
SHRD SHOWER DRAIN
SHT SHEET
SHT MTL FLASH SHEET METAL (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SK SKETCH
SKLT SKYLIGHT
SLD WDW HORIZONTAL SLIDING WINDOW
SLDG SLIDING
SLNT SEALANT
SM SHEET METAL
SMK SMOKE
SND SANITARY NAPKIN DISPENSER
SND INS SOUND INSULATION
S SOUTH
SNDU SANITARY NAPKIN DISPOSAL UNIT
SPEC SPECIFICATION
SPKLR SPRINKLER
SPKR SPEAKER
SPLY SUPPLY
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS SANITARY SEWER OR SERVICE SINK
SST STAINLESS STEEL
ST STAIRS OR STREET
STC SOUND TRANSMISSION CLASS
STD STANDARD
STIF STIFFENER
STL STEEL
STL LNTL STEEL LINTEL
STL RF DK STEEL ROOF DECK
STL TB STEEL TUBE
STNLS STAINLESS
STOR STORAGE
STR STRINGERS
STRUCT STRUCTURAL
SUB SUBSTITUTE
SURF SURFACE
SUSP SUSPEND
SV SHEET VINYL
SW SWITCH
SWDR SWING DOOR
SYM SYMBOL
SYNTH SYNTHETIC
SYS SYSTEM
T TREAD
TA TOILET ACCESSORY
T&G TONGUE AND GROOVE
T&M TIME AND MATERIALS
TB THROUGH BOLT OR TOWEL BAR
TCA TILE COUNCIL OF AMERICA
TCP TELEPHONE CONTROL PANEL OR TEMPERATURE
CONTROL PANEL OR TRAFFIC CONTROL PLAN
TD TOWEL DISPENSER
TECH TECHNICAL
TEL TELEPHONE
TEMP TEMPERATURE OR TEMPORARY
TER TERRAZZO
THD THREAD
THERM THERMAL
THK THICKNESS
THRES THRESHOLD
THRU THROUGH
THRUOUT THROUGHOUT
TK BD TACKBOARD
TMPD TEMPERED
TN TRUE NORTH
TO TOP OF ___
TO FDN TOP OF FOUNDATION
TOB TOP OF BEAM
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOS TOP OF STEEL
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPH TOILET PAPER HOLDER
TR TOWEL RACK
TRANS TRANSOM
TRANS WD FIN TRANSPARENT WOOD FINISH
TRTD TREATED
TS TENSILE STRENGTH OR TUBE STEEL
TSTAT THERMOSTAT
TV TELEVISION
TYP TYPICAL
U HEAT TRANSFER COEFFICIENT
UC UNDERCUT
UCD UNDERCUT DOOR
UGND UNDERGROUND
UL UNDERWRITERS LABORATORIES
ULT ULTIMATE
UNFIN UNFINISH
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
UR URINAL
UTIL UTILITY
UV ULTRAVIOLET
V VOLT
VAC VACUUM
VAR VARIES
VCT VINYL COMPOSITION TILE OR VITRIFIED CLAY TILE
VEH VEHICLE
VENT VENTILATION
VERT VERTICAL
VEST VESTIBULE
VFAT VINYL FACED ACOUSTICAL TILE
VIC VICINITY
VID VIDEO
VIF VERIFY IN FIELD
VNR VENEER
VOC VOLATILE ORGANIC COMPOUND
VOL VOLUME
VOLT VOLTAGE
VP VENEER PLASTER
VR VAPOR RETARDER
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
VWF VINYL WALL FABRIC
REVISION TO PLAN CALLOUT
WALLS
DOOR TAG
KEY NOTE TAGS
WALL TAG : REFER TO WALL LEGEND FOR MORE
INFORMATION
DOORS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
BID DOCUMENTS - REVISED 01/14/2020
BID DOCUMENTS 12/30/2019
95% CONSTRUCTION DOCUMENTS 10/15/2019
65% DESIGN DEVELOPMENT 08/13/2019
35% SCHEMATIC DESIGN 01/14/2018
BID DOCUMENTS - REVISED 03/20/2020
C U s e rs \e b ro w n
\D o c u m e n ts
\1 .1
.0
M a ri o n V
A S e c u ri ty
I m p ro v e m e n ts e b ro w n
M
S K
.r v t
/1
/2
:4
:5
P
M
AS001
ARCHITECTURAL SYMBOLS AND
ABBREVIATIONS
MARION VA SECURITY
IMPROVEMENTS
1700 E 38TH ST MARION IN 46953
610-15-105
15, 16, 17, 124, 127, 138, 172, 174, 185
JACOB MORRICAL - CHIEF
ENGINEER 12/30/2019 JLG ELB
BID DOCUMENTS
FULLY SPRINKLERED
BLDG
BLDG
BLDG
BLDG
BLDG 16
BLDG 15
BLDG
BLDG 124
BLDG 127
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
BID DOCUMENTS - REVISED 01/14/2020
BID DOCUMENTS 12/30/2019
95% CONSTRUCTION DOCUMENTS 10/15/2019
65% DESIGN DEVELOPMENT 08/13/2019
35% SCHEMATIC DESIGN 01/14/2018
BID DOCUMENTS - REVISED 03/20/2020
C U s e rs \e b ro w n
\D o c u m e n ts
\1 .1
.0
M a ri o n V
A S e c u ri ty
I m p ro v e m e n ts e b ro w n
M
S K
.r v t
/1
/2
:4
:0
P
M
AS002
OVERALL CAMPUS PLAN MARION VA SECURITY
IMPROVEMENTS
1700 E 38TH ST MARION IN 46953
610-15-105
15, 16, 17, 124, 127, 138, 172, 174, 185
JACOB MORRICAL - CHIEF
ENGINEER 12/30/2019 JLG ELB
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/2" = 1'-0"AS002
1 OVERALL CAMPUS PLAN
N
117 117A
119A
121B
113 114 115
121D
UP
S100 120 122 TC1
TELEPHONE EQUIP. CLOSET
C100
109C
C102
109B
110 109 105A 105B 104A 104 103
101 100
105C
109A C101
UP
121A
119 121C 121 123 124 125 126 127
UP
ELEVATOR MACHINE ROOM
S101
CORRIDOR TO BLDG. 16
PRO
DUCT
TRADENAM
E
M
ATERIAL
M O
DELNUMBER
PRO
DUCT
M O
DELNUMBER
M
ATERIAL
TRADENAM
E
PRO
DUCT
M
O
DELNUMBER
M
ATERIAL
TRADENAM
E
PRO
DUCT
M O
DELNUMBER
M
ATERIAL
TRADENAM
E
PRO
DUCT
M O
DELNUMBER
M
ATERIAL
TRADENAM
E
FLOOR PLAN GENERAL NOTES
A
B
C
ARCHITECTURAL KEY NOTES
VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING WORK, AND
REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.
CONTRACTOR TO MAINTAIN/REPAIR RATING OF EXISTING PARTITIONS AS
AFFECTED BY DEMOLITION/NEW CONSTRUCTION, TYPICAL THROUGHOUT.
SEAL OR FIRE CAULK WALL PENETRATIONS WHERE OCCUR. COORDINATE
WITH TECHNOLOGY DRAWINGS.
FIBER OPTIC BACKBONE CABLING AND DISTRIBUTION. REFER TO
TECHNOLOGY DRAWINGS. REMOVE AND SALVAGE CEILING TILE AND GRID
FOR CABLING INSTALLATION. TAKE CARE NOT TO DAMAGE CEILING TILE.
REPLACE ALL DAMAGED CEILING TILE. REINSTALL CEILING TILE AND GRID
WHEN WORK IS COMPLETED. UTILIZE ICRA CART FOR REMOVAL AND
REINSTALLATION OF CEILING TILES. FOLLOW ICRA PROCEDURES IN
REMOVING AND REINSTALLING CEILING GRID AND PANELS. PANELS MUST BE
REINSTALLED AT THE END OF THE DAY.
REFER TO TECHNOLOGY DRAWINGS FOR WORK.
ALARM PANEL LOCATION. REFER TO TECHNOLOGY DRAWINGS.
INTRUSION DETECTION PANEL. REFER TO TECHNOLOGY DRAWINGS.
MOTION DETECTORS WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
DATA CLOSET LOCATION. REFER TO TECHNOLOGY DRAWINGS.
WALL SLEEVE LOCATED WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
FLOOR SLEEVE LOCATED WITHIN ROOM. REFER TO TECHNOLOGY
DRAWINGS.
GLASS BREAK WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
CORE DRILLING WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
SIGNAL CLOSET LOCATION. REFER TO TECHNOLOGY DRAWINGS.
AREA REQUIRES SPECIAL ACCESS AND ESCORT AFTER HOURS.
DENOTES
AREA OF WORK
LEGEND
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
BID DOCUMENTS - REVISED 01/14/2020
BID DOCUMENTS 12/30/2019
95% CONSTRUCTION DOCUMENTS 10/15/2019
65% DESIGN DEVELOPMENT 08/13/2019
35% SCHEMATIC DESIGN 01/14/2018
BID DOCUMENTS - REVISED 03/20/2020
C U s e rs \e b ro w n
\D o c u m e n ts
\1 .1
.0
M a ri o n V
A S e c u ri ty
I m p ro v e m e n ts e b ro w n
M
S K
.r v t
/1
/2
:4
:3
P
M
15AS101
B-15 FIRST FLOOR ARCHITECTURAL
PLAN
MARION VA SECURITY
IMPROVEMENTS
1700 E 38TH ST MARION IN 46953
610-15-105
15, 16, 17, 124, 127, 138, 172, 174, 185
JACOB MORRICAL - CHIEF
ENGINEER 12/30/2019 JLG ELB
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"15AS101
1 B-15 FIRST FLOOR ARCHITECTURAL PLAN
CORRIDOR TO BLDG. 124
S200 203A
200A
DN
TC2
TELEPHONE EQUIP. CLOSET
C200
C202
215A
221 220 219 218 216 215 214 213 212 211 210 209
C201
201 202
203 204 205 206 207 208
DN
CORRIDOR TO BLDG. 16
S201
PRO
DUCT
M O
DELNUMBER
M
ATERIAL
TRADENAM
E
M O
DELNUMBER
PRO
DUCT
TRADENAM
E M
ATERIAL
M O
DELNUMBER
PRO
DUCT
TRADENAM
E M
ATERIAL
M
O
DELNUMBER
PRO
DUCT
TRADENAM
E
M
ATERIAL
M O
DELNUMBER
PRO
DUCT
TRADENAM
E M
ATERIAL
FLOOR PLAN GENERAL NOTES
A
B
C
ARCHITECTURAL KEY NOTES
VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING WORK, AND
REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.
CONTRACTOR TO MAINTAIN/REPAIR RATING OF EXISTING PARTITIONS AS
AFFECTED BY DEMOLITION/NEW CONSTRUCTION, TYPICAL THROUGHOUT.
SEAL OR FIRE CAULK WALL PENETRATIONS WHERE OCCUR. COORDINATE
WITH TECHNOLOGY DRAWINGS.
FIBER OPTIC BACKBONE CABLING AND DISTRIBUTION. REFER TO
TECHNOLOGY DRAWINGS. REMOVE AND SALVAGE CEILING TILE AND GRID
FOR CABLING INSTALLATION. TAKE CARE NOT TO DAMAGE CEILING TILE.
REPLACE ALL DAMAGED CEILING TILE. REINSTALL CEILING TILE AND GRID
WHEN WORK IS COMPLETED. UTILIZE ICRA CART FOR REMOVAL AND
REINSTALLATION OF CEILING TILES. FOLLOW ICRA PROCEDURES IN
REMOVING AND REINSTALLING CEILING GRID AND PANELS. PANELS MUST BE
REINSTALLED AT THE END OF THE DAY.
REFER TO TECHNOLOGY DRAWINGS FOR WORK.
ALARM PANEL LOCATION. REFER TO TECHNOLOGY DRAWINGS.
INTRUSION DETECTION PANEL. REFER TO TECHNOLOGY DRAWINGS.
MOTION DETECTORS WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
DATA CLOSET LOCATION. REFER TO TECHNOLOGY DRAWINGS.
WALL SLEEVE LOCATED WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
FLOOR SLEEVE LOCATED WITHIN ROOM. REFER TO TECHNOLOGY
DRAWINGS.
GLASS BREAK WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
CORE DRILLING WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
SIGNAL CLOSET LOCATION. REFER TO TECHNOLOGY DRAWINGS.
AREA REQUIRES SPECIAL ACCESS AND ESCORT AFTER HOURS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
BID DOCUMENTS - REVISED 01/14/2020
BID DOCUMENTS 12/30/2019
95% CONSTRUCTION DOCUMENTS 10/15/2019
65% DESIGN DEVELOPMENT 08/13/2019
35% SCHEMATIC DESIGN 01/14/2018
BID DOCUMENTS - REVISED 03/20/2020
C U s e rs \e b ro w n
\D o c u m e n ts
\1 .1
.0
M a ri o n V
A S e c u ri ty
I m p ro v e m e n ts e b ro w n
M
S K
.r v t
/1
/2
:4
:3
P
M
15AS102
B-15 SECOND FLOOR
ARCHITECTURAL PLAN
MARION VA SECURITY
IMPROVEMENTS
1700 E 38TH ST MARION IN 46953
610-15-105
15, 16, 17, 124, 127, 138, 172, 174, 185
JACOB MORRICAL - CHIEF
ENGINEER 12/30/2019 JLG ELB
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"15AS102
1 B-15 SECOND FLOOR ARCHITECTURAL PLAN
ELEVATOR
DN
100A
100B 134
C103
104A
106 107 108
S100
C100
C101
C102
111112
114A115A
UP
UP
UP
117A
OIT
UP
VITREO US CHINAC_LAVATO RYKING STO NK-2005
SOILED UTILITY
TRASH CHUTE
LINEN
CHUTE
FLOOR PLAN GENERAL NOTES
A
B
C
ARCHITECTURAL KEY NOTES
VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING WORK, AND
REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.
CONTRACTOR TO MAINTAIN/REPAIR RATING OF EXISTING PARTITIONS AS
AFFECTED BY DEMOLITION/NEW CONSTRUCTION, TYPICAL THROUGHOUT.
SEAL OR FIRE CAULK WALL PENETRATIONS WHERE OCCUR. COORDINATE
WITH TECHNOLOGY DRAWINGS.
FIBER OPTIC BACKBONE CABLING AND DISTRIBUTION. REFER TO
TECHNOLOGY DRAWINGS. REMOVE AND SALVAGE CEILING TILE AND GRID
FOR CABLING INSTALLATION. TAKE CARE NOT TO DAMAGE CEILING TILE.
REPLACE ALL DAMAGED CEILING TILE. REINSTALL CEILING TILE AND GRID
WHEN WORK IS COMPLETED. UTILIZE ICRA CART FOR REMOVAL AND
REINSTALLATION OF CEILING TILES. FOLLOW ICRA PROCEDURES IN
REMOVING AND REINSTALLING CEILING GRID AND PANELS. PANELS MUST BE
REINSTALLED AT THE END OF THE DAY.
REFER TO TECHNOLOGY DRAWINGS FOR WORK.
ALARM PANEL LOCATION. REFER TO TECHNOLOGY DRAWINGS.
INTRUSION DETECTION PANEL. REFER TO TECHNOLOGY DRAWINGS.
MOTION DETECTORS WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
DATA CLOSET LOCATION. REFER TO TECHNOLOGY DRAWINGS.
WALL SLEEVE LOCATED WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
FLOOR SLEEVE LOCATED WITHIN ROOM. REFER TO TECHNOLOGY
DRAWINGS.
GLASS BREAK WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
CORE DRILLING WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
SIGNAL CLOSET LOCATION. REFER TO TECHNOLOGY DRAWINGS.
AREA REQUIRES SPECIAL ACCESS AND ESCORT AFTER HOURS.
DENOTES
AREA OF WORK
LEGEND
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
BID DOCUMENTS - REVISED 01/14/2020
BID DOCUMENTS 12/30/2019
95% CONSTRUCTION DOCUMENTS 10/15/2019
65% DESIGN DEVELOPMENT 08/13/2019
35% SCHEMATIC DESIGN 01/14/2018
BID DOCUMENTS - REVISED 03/20/2020
C U s e rs \e b ro w n
\D o c u m e n ts
\1 .1
.0
M a ri o n V
A S e c u ri ty
I m p ro v e m e n ts e b ro w n
M
S K
.r v t
/1
/2
:4
:3
P
M
16AS101
B-16 FIRST FLOOR ARCHITECTURAL
PLAN
MARION VA SECURITY
IMPROVEMENTS
1700 E 38TH ST MARION IN 46953
610-15-105
15, 16, 17, 124, 127, 138, 172, 174, 185
JACOB MORRICAL - CHIEF
ENGINEER 12/30/2019 JLG ELB
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"16AS101
1 B-16 FIRST FLOOR ARCHITECTURAL PLAN
CORRIDOR TO
BUILIDNG 15
225 TRASH
CHUTE
S200 DN
200A
C202
221 C200 C201
200B
202 203 204
205 207 208
DN
SOILED
LINEN RM
219 216 214 213 212 211
217A
CORRIDOR TO
BUILIDNG 17
M O
DELNUMBER
PRO
DUCT
TRADENAM
E M
ATERIAL
PRO
DUCT
M O
DELNUMBER
M
ATERIAL
TRADENAM
E
M O
DELNUMBER
PRO
DUCT
TRADENAM
E M
ATERIAL
M O
DELNUMBER
PRO
DUCT
TRADENAM
E M
ATERIAL
PRO
DUCT
M
O
DELNUMBER
M
ATERIAL
TRADENAM
E
PRO
DUCT
M O
DELNUMBER
M
ATERIAL
TRADENAM
E
VITREO
US CHINA
C_LAVATO
RY
KING
STO
N K-2005
FLOOR PLAN GENERAL NOTES
A
B
C
ARCHITECTURAL KEY NOTES
VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING WORK, AND
REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.
CONTRACTOR TO MAINTAIN/REPAIR RATING OF EXISTING PARTITIONS AS
AFFECTED BY DEMOLITION/NEW CONSTRUCTION, TYPICAL THROUGHOUT.
SEAL OR FIRE CAULK WALL PENETRATIONS WHERE OCCUR. COORDINATE
WITH TECHNOLOGY DRAWINGS.
FIBER OPTIC BACKBONE CABLING AND DISTRIBUTION. REFER TO
TECHNOLOGY DRAWINGS. REMOVE AND SALVAGE CEILING TILE AND GRID
FOR CABLING INSTALLATION. TAKE CARE NOT TO DAMAGE CEILING TILE.
REPLACE ALL DAMAGED CEILING TILE. REINSTALL CEILING TILE AND GRID
WHEN WORK IS COMPLETED. UTILIZE ICRA CART FOR REMOVAL AND
REINSTALLATION OF CEILING TILES. FOLLOW ICRA PROCEDURES IN
REMOVING AND REINSTALLING CEILING GRID AND PANELS. PANELS MUST BE
REINSTALLED AT THE END OF THE DAY.
REFER TO TECHNOLOGY DRAWINGS FOR WORK.
ALARM PANEL LOCATION. REFER TO TECHNOLOGY DRAWINGS.
INTRUSION DETECTION PANEL. REFER TO TECHNOLOGY DRAWINGS.
MOTION DETECTORS WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
DATA CLOSET LOCATION. REFER TO TECHNOLOGY DRAWINGS.
WALL SLEEVE LOCATED WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
FLOOR SLEEVE LOCATED WITHIN ROOM. REFER TO TECHNOLOGY
DRAWINGS.
GLASS BREAK WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
CORE DRILLING WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
SIGNAL CLOSET LOCATION. REFER TO TECHNOLOGY DRAWINGS.
AREA REQUIRES SPECIAL ACCESS AND ESCORT AFTER HOURS.
2 1
6 10
DENOTES
AREA OF WORK
LEGEND
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
BID DOCUMENTS - REVISED 01/14/2020
BID DOCUMENTS 12/30/2019
95% CONSTRUCTION DOCUMENTS 10/15/2019
65% DESIGN DEVELOPMENT 08/13/2019
35% SCHEMATIC DESIGN 01/14/2018
BID DOCUMENTS - REVISED 03/20/2020
C U s e rs \e b ro w n
\D o c u m e n ts
\1 .1
.0
M a ri o n V
A S e c u ri ty
I m p ro v e m e n ts e b ro w n
M
S K
.r v t
/1
/2
:4
:3
P
M
16AS102
B-16 SECOND FLOOR
ARCHITECTURAL PLAN
MARION VA SECURITY
IMPROVEMENTS
1700 E 38TH ST MARION IN 46953
610-15-105
15, 16, 17, 124, 127, 138, 172, 174, 185
JACOB MORRICAL - CHIEF
ENGINEER 12/30/2019 JLG ELB
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"16AS102
1 B-16 SECOND FLOOR ARCHITECTURAL PLAN
300C
SOILED
UTILITY
300D
TRASH
CHUTE
S300 DN
300A
300B 323 324
302 303 304 305 306 307 308
320 C300 C301
322A S301
DN
322 321 316 315 314 313 312 311
S E
C O
N D
F L O
O R
R O
O F
S E
C O
N D
F L O
O R
R O
O F
M O
DELNUMBER
PRO
DUCT
TRADENAM
E M
ATERIAL
PRO
DUCT
M O
DELNUMBER
M
ATERIAL
TRADENAM
E
PRO
DUCT
M O
DELNUMBER
M
ATERIAL
TRADENAM
E
PRO
DUCT
M O
DELNUMBER
M
ATERIAL
TRADENAM
E M
O
DELNUMBER
PRO
DUCT
TRADENAM
E
M
ATERIAL
M O
DELNUMBER
PRO
DUCT
TRADENAM
E M
ATERIAL
M
O
DELNUMBER
PRO
DUCT
TRADENAM
E
M
ATERIAL
VITREO
US CHINA
C_LAVATO
RY
KING
STO
N K-2005
FLOOR PLAN GENERAL NOTES
A
B
C
ARCHITECTURAL KEY NOTES
VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING WORK, AND
REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.
CONTRACTOR TO MAINTAIN/REPAIR RATING OF EXISTING PARTITIONS AS
AFFECTED BY DEMOLITION/NEW CONSTRUCTION, TYPICAL THROUGHOUT.
SEAL OR FIRE CAULK WALL PENETRATIONS WHERE OCCUR. COORDINATE
WITH TECHNOLOGY DRAWINGS.
FIBER OPTIC BACKBONE CABLING AND DISTRIBUTION. REFER TO
TECHNOLOGY DRAWINGS. REMOVE AND SALVAGE CEILING TILE AND GRID
FOR CABLING INSTALLATION. TAKE CARE NOT TO DAMAGE CEILING TILE.
REPLACE ALL DAMAGED CEILING TILE. REINSTALL CEILING TILE AND GRID
WHEN WORK IS COMPLETED. UTILIZE ICRA CART FOR REMOVAL AND
REINSTALLATION OF CEILING TILES. FOLLOW ICRA PROCEDURES IN
REMOVING AND REINSTALLING CEILING GRID AND PANELS. PANELS MUST BE
REINSTALLED AT THE END OF THE DAY.
REFER TO TECHNOLOGY DRAWINGS FOR WORK.
ALARM PANEL LOCATION. REFER TO TECHNOLOGY DRAWINGS.
INTRUSION DETECTION PANEL. REFER TO TECHNOLOGY DRAWINGS.
MOTION DETECTORS WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
DATA CLOSET LOCATION. REFER TO TECHNOLOGY DRAWINGS.
WALL SLEEVE LOCATED WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
FLOOR SLEEVE LOCATED WITHIN ROOM. REFER TO TECHNOLOGY
DRAWINGS.
GLASS BREAK WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
CORE DRILLING WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
SIGNAL CLOSET LOCATION. REFER TO TECHNOLOGY DRAWINGS.
AREA REQUIRES SPECIAL ACCESS AND ESCORT AFTER HOURS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
BID DOCUMENTS - REVISED 01/14/2020
BID DOCUMENTS 12/30/2019
95% CONSTRUCTION DOCUMENTS 10/15/2019
65% DESIGN DEVELOPMENT 08/13/2019
35% SCHEMATIC DESIGN 01/14/2018
BID DOCUMENTS - REVISED 03/20/2020
C U s e rs \e b ro w n
\D o c u m e n ts
\1 .1
.0
M a ri o n V
A S e c u ri ty
I m p ro v e m e n ts e b ro w n
M
S K
.r v t
/1
/2
:4
:3
P
M
16AS103
B-16 THIRD FLOOR
ARCHITECTURAL PLAN
MARION VA SECURITY
IMPROVEMENTS
1700 E 38TH ST MARION IN 46953
610-15-105
15, 16, 17, 124, 127, 138, 172, 174, 185
JACOB MORRICAL - CHIEF
ENGINEER 12/30/2019 JLG ELB
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"16AS103
1 B-16 THIRD FLOOR ARCHITECTURAL PLAN
CORRIDOR TO BLDG. 16
ELEVATOR MACHINE ROOM
EM1
ENTRANCE TO CRAWL SPACE
S100
TC1
103A
PIPE
C100
UP
S101
124 123 122
119B 121A
UP
CHASE
104 105
107 108 109 110 111
UP
119A
118A 117A
117 115 114 113 112
RAMP DOWN
PRO
DUCT
M O
DELN
UM
BER
M
ATERIAL
TRADEN
AM
E
M O
DELN
UM
BER
PRO
DUCT
TRADEN
AM
E
M
ATERIAL
M O
DELN
UM
BER
PRO
DUCT
TRADEN
AM
E
M
ATERIAL
PRO
DUCT
M O
DELN
UM
BER
M
ATERIAL
TRADEN
AM
E
PRO
DUCT
M O
DELN
UM
BER
M
ATERIAL
TRADEN
AM
E
M O
DELN
UM
BER
PRO
DUCT
TRADEN
AM
E
M
ATERIAL
M O
DELN
UM
BER
PRO
DUCT
M
ATERIAL
TRADEN
AM
E
FLOOR PLAN GENERAL NOTES
A
B
C
ARCHITECTURAL KEY NOTES
VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING WORK, AND
REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.
CONTRACTOR TO MAINTAIN/REPAIR RATING OF EXISTING PARTITIONS AS
AFFECTED BY DEMOLITION/NEW CONSTRUCTION, TYPICAL THROUGHOUT.
SEAL OR FIRE CAULK WALL PENETRATIONS WHERE OCCUR. COORDINATE
WITH TECHNOLOGY DRAWINGS.
FIBER OPTIC BACKBONE CABLING AND DISTRIBUTION. REFER TO
TECHNOLOGY DRAWINGS. REMOVE AND SALVAGE CEILING TILE AND GRID
FOR CABLING INSTALLATION. TAKE CARE NOT TO DAMAGE CEILING TILE.
REPLACE ALL DAMAGED CEILING TILE. REINSTALL CEILING TILE AND GRID
WHEN WORK IS COMPLETED. UTILIZE ICRA CART FOR REMOVAL AND
REINSTALLATION OF CEILING TILES. FOLLOW ICRA PROCEDURES IN
REMOVING AND REINSTALLING CEILING GRID AND PANELS. PANELS MUST BE
REINSTALLED AT THE END OF THE DAY.
REFER TO TECHNOLOGY DRAWINGS FOR WORK.
ALARM PANEL LOCATION. REFER TO TECHNOLOGY DRAWINGS.
INTRUSION DETECTION PANEL. REFER TO TECHNOLOGY DRAWINGS.
MOTION DETECTORS WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
DATA CLOSET LOCATION. REFER TO TECHNOLOGY DRAWINGS.
WALL SLEEVE LOCATED WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
FLOOR SLEEVE LOCATED WITHIN ROOM. REFER TO TECHNOLOGY
DRAWINGS.
GLASS BREAK WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
CORE DRILLING WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
SIGNAL CLOSET LOCATION. REFER TO TECHNOLOGY DRAWINGS.
AREA REQUIRES SPECIAL ACCESS AND ESCORT AFTER HOURS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
BID DOCUMENTS - REVISED 01/14/2020
BID DOCUMENTS 12/30/2019
95% CONSTRUCTION DOCUMENTS 10/15/2019
65% DESIGN DEVELOPMENT 08/13/2019
35% SCHEMATIC DESIGN 01/14/2018
BID DOCUMENTS - REVISED 03/20/2020
C U s e rs \e b ro w n
\D o c u m e n ts
\1 .1
.0
M a ri o n V
A S e c u ri ty
I m p ro v e m e n ts e b ro w n
M
S K
.r v t
/1
/2
:4
:3
P
M
17AS101
B-17 FIRST FLOOR ARCHITECTURAL
PLAN
MARION VA SECURITY
IMPROVEMENTS
1700 E 38TH ST MARION IN 46953
610-15-105
15, 16, 17, 124, 127, 138, 172, 174, 185
JACOB MORRICAL - CHIEF
ENGINEER 12/30/2019 JLG ELB
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"17AS101
1 B-17 FIRST FLOOR ARCHITECTURAL PLAN
CORRIDOR TO BLDG. 16
S200
TC2
203A
C200
PIPE
CHASE
203 206 207 208 209
DN
C201
DN
216A
222 221 220 219 218
S201
216 215 214 213 212 211
PRO
DUCT
M O
DELNUMBER
M
ATERIAL
TRADENAM
E
M O
DELNUMBER
PRO
DUCT
TRADENAM
E M
ATERIAL
M
O
DELNUMBER
PRO
DUCT
TRADENAM
E
M
ATERIAL
M O
DELNUMBER
PRO
DUCT
TRADENAM
E M
ATERIAL
M O
DELNUMBER
PRO
DUCT
TRADENAM
E M
ATERIAL
FLOOR PLAN GENERAL NOTES
A
B
C
ARCHITECTURAL KEY NOTES
VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING WORK, AND
REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.
CONTRACTOR TO MAINTAIN/REPAIR RATING OF EXISTING PARTITIONS AS
AFFECTED BY DEMOLITION/NEW CONSTRUCTION, TYPICAL THROUGHOUT.
SEAL OR FIRE CAULK WALL PENETRATIONS WHERE OCCUR. COORDINATE
WITH TECHNOLOGY DRAWINGS.
FIBER OPTIC BACKBONE CABLING AND DISTRIBUTION. REFER TO
TECHNOLOGY DRAWINGS. REMOVE AND SALVAGE CEILING TILE AND GRID
FOR CABLING INSTALLATION. TAKE CARE NOT TO DAMAGE CEILING TILE.
REPLACE ALL DAMAGED CEILING TILE. REINSTALL CEILING TILE AND GRID
WHEN WORK IS COMPLETED. UTILIZE ICRA CART FOR REMOVAL AND
REINSTALLATION OF CEILING TILES. FOLLOW ICRA PROCEDURES IN
REMOVING AND REINSTALLING CEILING GRID AND PANELS. PANELS MUST BE
REINSTALLED AT THE END OF THE DAY.
REFER TO TECHNOLOGY DRAWINGS FOR WORK.
ALARM PANEL LOCATION. REFER TO TECHNOLOGY DRAWINGS.
INTRUSION DETECTION PANEL. REFER TO TECHNOLOGY DRAWINGS.
MOTION DETECTORS WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
DATA CLOSET LOCATION. REFER TO TECHNOLOGY DRAWINGS.
WALL SLEEVE LOCATED WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
FLOOR SLEEVE LOCATED WITHIN ROOM. REFER TO TECHNOLOGY
DRAWINGS.
GLASS BREAK WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
CORE DRILLING WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
SIGNAL CLOSET LOCATION. REFER TO TECHNOLOGY DRAWINGS.
AREA REQUIRES SPECIAL ACCESS AND ESCORT AFTER HOURS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
BID DOCUMENTS - REVISED 01/14/2020
BID DOCUMENTS 12/30/2019
95% CONSTRUCTION DOCUMENTS 10/15/2019
65% DESIGN DEVELOPMENT 08/13/2019
35% SCHEMATIC DESIGN 01/14/2018
BID DOCUMENTS - REVISED 03/20/2020
C U s e rs \e b ro w n
\D o c u m e n ts
\1 .1
.0
M a ri o n V
A S e c u ri ty
I m p ro v e m e n ts e b ro w n
M
S K
.r v t
/1
/2
:4
:3
P
M
17AS102
B-17 SECOND FLOOR
ARCHITECTURAL PLAN
MARION VA SECURITY
IMPROVEMENTS
1700 E 38TH ST MARION IN 46953
610-15-105
15, 16, 17, 124, 127, 138, 172, 174, 185
JACOB MORRICAL - CHIEF
ENGINEER 12/30/2019 JLG ELB
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"17AS102
1 B-17 SECOND FLOOR ARCHITECTURAL PLAN
Courtyard
Paved
Area
111A
109A
DN TO BSMT
110 112 Lower Level Light well
UP
113A
C104
S101 S100 UP 127
Courtyard
Landscape
112A 115A
114 115
Connecting
Corridor
C103
117A
C101
105A
107 106 105 104 103 100
C100
118 119 120
LADDER TO
CRAWL SPACE
C102
136 135 134 133 132 131 130
PRO
DUCT
M O
DELNUMBER
M
ATERIAL
TRADENAM
E
PRO
DUCT
M O
DELNUMBER
M
ATERIAL
TRADENAM
E
PRO
DUCT
M O
DELNUMBER
M
ATERIAL
TRADENAM
E
B
D is p la y C a s e
A PRO
DUCT
M
O
DELNUMBER
M
ATERIAL
TRADENAM
E
C_TO
ILETS
K-4386ANG
LESEY
VITREO
US CHINA
C_TO
ILETS
K-4386ANG
LESEY
VITREO
US CHINA
R a m p
D o w n
FLOOR PLAN GENERAL NOTES
A
B
C
ARCHITECTURAL KEY NOTES
VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING WORK, AND
REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.
CONTRACTOR TO MAINTAIN/REPAIR RATING OF EXISTING PARTITIONS AS
AFFECTED BY DEMOLITION/NEW CONSTRUCTION, TYPICAL THROUGHOUT.
SEAL OR FIRE CAULK WALL PENETRATIONS WHERE OCCUR. COORDINATE
WITH TECHNOLOGY DRAWINGS.
FIBER OPTIC BACKBONE CABLING AND DISTRIBUTION. REFER TO
TECHNOLOGY DRAWINGS. REMOVE AND SALVAGE CEILING TILE AND GRID
FOR CABLING INSTALLATION. TAKE CARE NOT TO DAMAGE CEILING TILE.
REPLACE ALL DAMAGED CEILING TILE. REINSTALL CEILING TILE AND GRID
WHEN WORK IS COMPLETED. UTILIZE ICRA CART FOR REMOVAL AND
REINSTALLATION OF CEILING TILES. FOLLOW ICRA PROCEDURES IN
REMOVING AND REINSTALLING CEILING GRID AND PANELS. PANELS MUST BE
REINSTALLED AT THE END OF THE DAY.
REFER TO TECHNOLOGY DRAWINGS FOR WORK.
ALARM PANEL LOCATION. REFER TO TECHNOLOGY DRAWINGS.
INTRUSION DETECTION PANEL. REFER TO TECHNOLOGY DRAWINGS.
MOTION DETECTORS WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
DATA CLOSET LOCATION. REFER TO TECHNOLOGY DRAWINGS.
WALL SLEEVE LOCATED WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
FLOOR SLEEVE LOCATED WITHIN ROOM. REFER TO TECHNOLOGY
DRAWINGS.
GLASS BREAK WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
CORE DRILLING WITHIN ROOM. REFER TO TECHNOLOGY DRAWINGS.
SIGNAL CLOSET LOCATION. REFER TO TECHNOLOGY DRAWINGS.
AREA REQUIRES SPECIAL ACCESS AND ESCORT AFTER HOURS.
1 2
1 2 6
DENOTES
AREA OF WORK
LEGEND
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
BID DOCUMENTS - REVISED 01/14/2020
BID DOCUMENTS 12/30/2019
95% CONSTRUCTION DOCUMENTS 10/15/2019
65% DESIGN DEVELOPMENT 08/13/2019
35% SCHEMATIC DESIGN 01/14/2018
BID DOCUMENTS - REVISED 03/20/2020
C U s e rs \e b ro w n
\D o c u m e n ts
\1 .1
.0
M a ri o n V
A S e c u ri ty
I m p ro v e m e n ts e b ro w n
M
S K
.r v t
/1
/2
:4
:4
P
M
124AS101
B-124 FIRST FLOOR
ARCHITECTURAL PLAN
MARION VA SECURITY
IMPROVEMENTS
1700 E 38TH ST MARION IN 46953
610-15-105
15, 16, 17, 124, 127, 138, 172, 174, 185
JACOB MORRICAL - CHIEF
ENGINEER 12/30/2019 JLG ELB
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"124AS101
1 B-124 FIRST FLOOR ARCHITECTURAL PLAN
226C 227 206
226A
227A
226B
229A
DN
C204 224 230
233A
C201
218B
220A
218A
223 222 221 220 218
217 215 214 213
211A
233 234 C203
200A
C200
201 202 203 C202
DN
227B 207
PRO
DUCT
M
ATERIAL
M O
DELNUMBER
TRADENAM
E
M O
DELNUMBER
PRO
DUCT
TRADENAM
E…
This is the start of the file's text. The full file is on GovTribe.