This is a tower inspection report and antenna installation documentation for a WLPB TV 990-foot tower inspection conducted on August 18, 2025, related to a transmission line installation project for Louisiana's LETA (Louisiana Educational Television Authority). The file contains detailed section-by-section inspection findings documenting structural deficiencies, maintenance issues, and equipment problems throughout the tower, including loose and improperly routed flexible transmission lines, missing hangers across multiple sections (sections 5, 6, 10, 11, 12, 13, 18), bent and damaged horizontal members (section 15), damaged diagonal members (section 39), improperly secured Kellum grips, rust on safety climb cable systems, and a missing safety climb system on the transition climbing ladder from bay 1 through bay 4. The documentation also includes photographs illustrating typical views of identified deficiencies and mechanical specifications for a cascade antenna assembly (project 40177) manufactured by Electronics Research Inc., detailing lifting procedures, shipping details, mounting specifications, and connection requirements for a 4,400-pound antenna system designed for installation on the tower top plate.
The inspection report provides detailed photographic evidence and technical specifications necessary for remediation planning and antenna installation coordination. The antenna installation documentation includes comprehensive lifting and shipping details with specific rigging attachment points, mounting flange specifications, torque requirements for hardware assembly, and plumbing tolerances requiring the antenna to be within 0.1 degrees from vertical. Bill of materials and mechanical parameter drawings specify hardware grades (ASTM A325 bolts, ANCO locknuts, F436 flat washers), cable specifications, grounding kits, lightning protection components, and climbing pole assemblies. The contract appears to address tower maintenance, repair of identified structural and transmission line deficiencies, and installation of updated antenna equipment to restore the transmission facility to proper operational standards.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 3000026811.pdf | ||
| Attachment B - Job Site Verification Form - Page 1.docx | DOCX document | |
| Attachment C - Specifications - Page 1.docx | DOCX document | |
| Attachment A - Special Terms and Conditions Pages 1-15.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WLPB TV 990’ Tower Inspection
August 18th, 2025
TOWER SECTION DETAIL
This section of the report details any problems with the structural condition, flexible transmission lines, paint, lighting/conduit systems, ladder, or safety climb equipment, rusting, or side mounted antenna problems. The format is “section-by-section” numbering from the ground up. The first vertical section is #1.
List Section # Details
Typical There are loose and improperly routed flexible transmission lines through-out the horizontal bridge and tower.
Section #5 There are (3) missing hangers for the EW63 flexible transmission line.
Section #6 There are (4) missing hangers for the 3” flexible transmission line.
Section #7 There is (1) kinked flex jumper for the two-way type of antenna on the #2.
Section #8 There is (1) improperly secured ground for the 3” flexible transmission line.
Section #10 There are (3) missing hangers for the 3” flexible transmission line.
Section #11 There are (4) missing hangers for the 3” flexible transmission line.
Section #12 There are (4) missing hangers for the 3” flexible transmission line.
Section #13 There is (1) missing hanger for the 3” flexible transmission line in bay #2.
Section #15 There is (1) bent horizontal member on the x-face in bay #2.
Section #17 There is (1) damaged flexible transmission line grounding in bay #3.
There is (1) missing hanger for the 3” flexible transmission line in bay #3.
Section #18 There are (5) missing hangers for the 7/8” flexible transmission line in bay
#2. There are (3) missing hangers for the 3” flexible transmission line.
Section #20 There is (1) unsecured flex jumper on the a-leg.
Section #21 There are (2) improperly secured Kellum grips for the 7/8” flexible trans-mission lines.
Section #23 There is (1) missing ground for the flexible transmission line in bay #2.
Section #28 There is (1) improperly secured Kellum grip in bay #3.
Section #32 There is (1) missing ground for the 1-1/4” flexible transmission line
There is (1) improperly secured Kellum grip in bay #2.
Section #33 There is (1) abandoned 2-bay FM antenna on the c-leg.
Section #35 There is (1) improper ground for the 3” flexible transmission line in bay
#2.
Section #39
There are (2) damaged diagonal members on the x-face in bay #2. There is (1) abandoned hanger in bay #4. There is no safety climb on the transi-tion ladder from bay #1 through #4.
Attachment D - Tower Details and Photos RFx: 300026811
TOWER CROSS SECTION DRAWING
PHOTOGRAPHS
The upper photo shows a typical view of the bent horizontal member in section #15. The lower photo shows a typical view of the (2) damaged diagonal members in section #39.
PHOTOGRAPHS
The photo shows a typical view of no personnel safety climb system on the transition climbing ladder at the tower top.
PHOTOGRAPHS
The photos show typical views of the improperly mounted upper bracket of the safety climb system on the main climbing ladder.
PHOTOGRAPHS
The photos show typical views of the medium to heavy surface rust on the personnel ladder safety climb cable.
PHOTOGRAPHS
The photos show typical views of the (3) flexible transmission lines secured to the main climbing ladder.
PHOTOGRAPHS
The photo shows a typical view of loose and improperly installed flexible transmission lines.
PHOTOGRAPHS
The upper photo shows a typical view of improper Kellum grips for flexible transmission lines.
The lower photo shows a typical view of a missing Kellum grip for flexible transmission lines.
PHOTOGRAPHS
The left photo shows a typical view of a missing Kellum grip for flexible transmission lines. The right photo shows a typical view of improper Kellum grips for flexible transmission lines.
PHOTOGRAPHS
The photos show typical views of loose and improperly installed flexible transmission lines.
PHOTOGRAPHS
The photos show the kinked flex jumper for the dish antenna in section #7.
PHOTOGRAPHS
The upper photo shows a typical view of the abandoned hanger in section #39. The lower photo shows a typical view of the abandoned 2-bay FM in section #33.
PHOTOGRAPHS
The upper photo shows a typical view of the AOL and lightning arrester system on the top mounted TV antenna. The lower photo shows a typical view of the top mounted TV antenna.
VE
R
TI
CA
L O
N
LY
4 3
FIGURE #1
2 1
REVISION HISTORY
REMOVAL FROM TRUCK
2x 1
LIFTING SHACKLE
REV DESCRIPTION DATE APPROVED
A ADD FINAL DATA 6/6/2024 K. SCHARP
LIFT ANTENNA FROM TRUCK BED USING "YELLOW" ANTENNA LIFTING 4x 4x 4x
PLATES, NOT THE RADOMES, AT THE LOCATIONS INDICATED.
TO PREVENT ROLLING, LIFT FROM THE PLATES
AS SHOWN IN VIEW "W-W". DO NOT LIFT ANTENNA
BY RADOMES, DAMAGE WILL OCCUR.
NOTES:
4 3 2
(25.00)
LIFTING SHACKLE
2 3 4
B 1. THE LIFTING DETAILS PROVIDED IDENTIFY THE PRIMARY RIGGING ATTACHMENT POINTS ON
THE ANTENNA FOR DELIVERY LOADING/UNLOADING, UPENDING, AND HOISTING OPERATIONS.
2. ALL RIGGING COMPONENTS SHALL BE PROPERLY SELECTED AND SIZED BY THE
CONTRACTOR'S QUALIFIED PERSON TO ENSURE THE COMPONENTS ARE UTILIZED IN
ACCORDANCE WITH RIGGING MANUFACTURER'S WLL LIMITS AND ASSOCIATED SPECIFICATIONS.
3. CONTACT ERI FOR REVIEW AND APPROVAL IF ALTERNATE RIGGING ATTACHMENT POINTS
ARE NEEDED FOR HANDLING OR HOISTING OPERATIONS.
(478.42) O.A.L.
SECTION W-W
SCALE 1/10
X (Ø18.18)
DO NOT PUSH ON RADOME
ALONG DATUM X
B
DETAIL A
(TYP.)
SCALE 1/8
12.00 289.30
(ANTENNA WEIGHT = 4,400 LBS)
SEE DETAIL "A" W
.00
TRUCK BED WOOD LEVELING BLOCK W
301.65
WOOD LEVELING BLOCK
469.70
(MTG. SURFACE)
A
LIFTING PLATE PLATE
TITLE:
ELECTRONICS RESEARCH INC.
ESTABLISHED 1943
R
7777 GARDNER Rd.
CHANDLER, IN
47610-9219
PHONE: (812) 925-6000
FAX: (812) 925-4030
This document/drawing contains information considered confidential by Electronics Research, Inc. ("ERI"). This information is disclosed on a confidential basis and only authorized for use in the installation, operation, THIRD ANGLE PROJECTION
MATERIAL
FINISH
TOLERANCES
OVERALL-NOT CUMULATIVE
UNLESS OTHERWISE SPECIFIED,
1 PLACE DECIMAL ± .1
2 PLACE DECIMAL ± .03 3 PLACE DECIMAL ± .010
MANUF.
LIFTING / SHIPPING DETAILS
40177 - BATON ROUGE, LA - CH. 25
and maintenance of ERI tower and antenna equipment, as appropriate. ALL DIMENSIONS ARE IN INCHES ANGULAR ± .5° EXT. APPROVAL SIZE CAGE CODE LD40177-1 REV.
Reproduction, transmission or disclosure to others, or unauthorized use, without the express written consent of ERI, is strictly prohibited.
UNAUTHORIZED DUPLICATION, REPRODUCTION, OR DISCLOSURE OF
THIS INFORMATION IS A VIOLATION OF FEDERAL LAW.
COPYRIGHT 2023 ERI, ELECTRONICS RESEARCH INC.
C:\Users\ggott\Documents\Vault\Designs\40177\1\LD40177-1.idwggott3/18/2024 3
AND APPLICABLE AT 20°C (68°F)
INTERPRET DIMENSIONS AND TOLERANCES
PER ASME Y14.5M-1994
FRACTIONAL ± 1/16"
LEG HOLE -0", +1/16"
SUPERSEDES PART NO.
FILE NAME: LD40177-1.idw
B
SCALE :
OZNS1
AS NOTED
WEIGHT: SHEET:
N/A
A
LI
FT
L
IF
T
VE
R
TI
CA
L
O N
LY
DWG NO.
4 4 NU1210GA 3/4 - 10 GALV. HEX NUT
3 4 WF12GA 3/4" FLAT WASHER F436 HDG STRUCTURAL
2 4 SC1210H0300GA 3/4 - 10 x 3.00 LG (1.38" MIN THREADS) A325 BOLT
1 2 LLTRIUP001 "YELLOW" LIFTING LUG FOR CASCADE ANTENNA
TEM QTY PART NUMBER DESCRIPTION
BILL OF MATERIAL
PROJECT NO. 40177/1
ERI APPROVAL NAME DATE
DRAWN BY G.A.G. 3/18/2024
DRAFTING
DESIGN MGR. K. SCHARP 3/28/2024
ENG. J.H. 4/3/2024
4 3 2 1
FIGURE #2
PLACE ANTENNA WOODEN SUPPORTS AS SHOWN.
ANTENNA SHOULD BE LEVEL TO PREVENT DAMAGE.
USE SUPPORTS HIGH ENOUGH TO AVOID DAMAGING THE RADOMES AND TO ALLOW FOR
ELECTRICAL GROUND TEST OF THE ANTENNA. PLATES RESTING 6.0 INCHES ABOVE
THE GROUND IS SUFFICIENT.
B B
WOOD SUPPORTS
GROUND TO LEVEL ANTENNA
WOOD SUPPORTS
TO LEVEL ANTENNA
A A
PROJECT NO.
ERI APPROVAL
DRAWN BY
DRAFTING
DESIGN MGR.
40177/1
NAME
G.A.G.
K. SCHARP
DATE
3/18/2024
3/28/2024
7777 GARDNER Rd.
CHANDLER, IN
47610-9219
ENG.
J.H. 4/3/2024 40177 - BATON ROUGE, LA - CH. 25
and maintenance of ERI tower and antenna equipment, as appropriate. ALL DIMENSIONS ARE IN INCHES ANGULAR ± .5° EXT. APPROVAL SIZE CAGE CODE LD40177-1 REV.
Reproduction, transmission or disclosure to others, or unauthorized use, without the express written consent of ERI, is strictly prohibited.
UNAUTHORIZED DUPLICATION, REPRODUCTION, OR DISCLOSURE OF
THIS INFORMATION IS A VIOLATION OF FEDERAL LAW.
COPYRIGHT 2023 ERI, ELECTRONICS RESEARCH INC.
AND APPLICABLE AT 20°C (68°F)
INTERPRET DIMENSIONS AND TOLERANCES
PER ASME Y14.5M-1994
B
SCALE :
A
FIGURE #3
WHEN LIFTING THE ANTENNA FOR INSTALLATION, LIFT AS SHOWN TO
PREVENT DAMAGE TO THE BASE OF THE ANTENNA. WHEN THE ANTENNA
IS VERTICAL, THE ADDITIONAL BASE LIFTING CABLE CAN BE REMOVED.
NOTE: THIS ILLUSTRATION IS INTENDED TO SHOW A CONCEPT FOR
LIFTING THE ERI INC. TRASAR ANTENNA TO PREVENT DAMAGE TO THE
ANTENNA AND THE RADOMES. SAFE AND PROPER IMPLEMENTATION OF
THIS CONCEPT ARE THE RESPONSIBILITY OF THE INSTALLER.
MAIN LIFTING CABLE
ADDITIONAL LIFTING CABLE
ATTACH MAIN
LIFTING CABLES
TO LIFTING PLATES
DRAWN BY
40177/1
NAME
3/18/2024
ESTABLISHED 1943
R
7777 GARDNER Rd.
CHANDLER, IN
47610-9219
DRAFTING
DESIGN MGR.
J.H.
3/28/2024
4/3/2024
LIFTING / SHIPPING DETAILS
40177 - BATON ROUGE, LA - CH. 25
and maintenance of ERI tower and antenna equipment, as appropriate. ALL DIMENSIONS ARE IN INCHES ANGULAR ± .5° EXT. APPROVAL SIZE CAGE CODE LD40177-1 REV.
Reproduction, transmission or disclosure to others, or unauthorized use, without the express written consent of ERI, is strictly prohibited.
UNAUTHORIZED DUPLICATION, REPRODUCTION, OR DISCLOSURE OF
THIS INFORMATION IS A VIOLATION OF FEDERAL LAW.
COPYRIGHT 2023 ERI, ELECTRONICS RESEARCH INC.
B
SCALE :
A
FIGURE #4
AFTER ANTENNA IS MOUNTED VERICALLY, REMOVE "YELLOW" LIFTING PLATES & HARDWARE.
INSTALL ANTENNA RADOME COVERS. SEE DETAIL "A".
REMOVE "YELLOW" LIFTING
PLATE & HARDWARE
SEE DETAIL "A"
ASSEMBILED RADOME SECTION
SCALE 1/15
4x 4x 4x 4x
4 5 6 8
NOTE:
1 TORQUE 1/4" HARDWARE
TO 6 FT/LBS
A DETAIL A
(TYP. EACH SIDE)
SCALE 1 / 5
10x 10x 10x 10x 10x
3 4 5 6 7
ITEM
QTY
PART NUMBER
DESCRIPTION
7777 GARDNER Rd.
REMOVE "YELLOW" LIFTING
PLATE & HARDWARE
TOWER TOP
PLATE
ESTABLISHED 1943
R
CHANDLER, IN
47610-9219
40177 - BATON ROUGE, LA - CH. 25
and maintenance of ERI tower and antenna equipment, as appropriate. ALL DIMENSIONS ARE IN INCHES ANGULAR ± .5° EXT. APPROVAL SIZE CAGE CODE LD40177-1 REV.
Reproduction, transmission or disclosure to others, or unauthorized use, without the express written consent of ERI, is strictly prohibited.
UNAUTHORIZED DUPLICATION, REPRODUCTION, OR DISCLOSURE OF
THIS INFORMATION IS A VIOLATION OF FEDERAL LAW.
COPYRIGHT 2023 ERI, ELECTRONICS RESEARCH INC.
B
SCALE :
A
DWG NO.
8 8 RW001 RADOME WASHER
7 20 WF05.5SS FLATWASHER, SS
6 24 WL04SS 1/4 in, SS LOCK WASHER 5 28 WF04SS 1/4 in, SS FLAT WASHER 4 28 SC0420H0087 1/4-20 UNC x 0.875 in, SST HEX BOLT
3 20 RTN0003 RIVET NUT
2 1 RAUN40177-2-OR UNPRESSURIZED CASCADE RADOME COVER (Ø18")
1 1 RAUN40177-6-OR UNPRESSURIZED CASCADE RADOME COVER (Ø18")
PROJECT NO. 40177/1
ERI APPROVAL NAME DATE
DRAWN BY G.A.G. 3/18/2024
DRAFTING
DESIGN MGR. K. SCHARP 3/28/2024
ENG. J.H. 4/3/2024
NOTES:
3 2 1
REVISION HISTORY
1. REMOVE ALL BURRS AND SHARP EDGES.
2. LOC-TITE ALL THREADS PER BOP 2.02.01.
3. TORQUE ALL 1/4" HARDWARE TO 6 FT/LBS.
4. TORQUE ALL 5/8" HARDWARE TO 60-65 FT/LBS.
5. TORQUE ALL 1/2" HARDWARE TO 50-65 FT/LBS.
6. TORQUE ALL 3/8" HARDWARE TO 28 FT/LBS.
B 7. ALL EXTERIOR HARDWARE TO BE ASSEMBLED WITH THE HEAD OF THE BOLT TOWARDS THE BOTTOM OF THE ANTENNA.
8. USE SMALL ERI SHIPPING LABEL WHERE NOTED.
9. USING BLACK PAINT, STENCIL AS SHOWN, USING MIN. 1/2" HIGH CHARACTERS.
10. BEND TONGUE OF CABLE GRIP SUPPORT (ITEM #14) TO CAPTIVATE THE CABLE GRIP.
11. APPLY TEFLON TAPE TO THREADS ON TOP OF CLIMBING POLE.
CONNECTION NOTES:
1. FOR PROPER PERFORMANCE AFTER INSTALLATION, PLUMB THE ANTENNA TO WITHIN 0.1°
FROM VERTICAL (5/8 INCH IN 30 FEET). A KIT OF SHIMS IS INCLUDED WITH THE ANTENNA.
AS REQUIRED FOR PROPER PLUMB, GAPS BETWEEN ANTENNA MOUNTING FLANGE AND TOWER
TOP PLATE MUST BE FILLED USING THE SUPPLIED SHIM KIT OR SUITABLE STEEL SHIM STOCK.
2. ANTENNA MOUNTING FLANGE BOLTED CONNECTION SHALL BE BROUGHT TO A SNUG-TIGHT CONDITION
WHERE JOINT TIGHTNESS IS ATTAINED WITH A FEW IMPACTS OF AN IMPACT WRENCH OR FULL EFFORT OF AN IRONWORKER USING AN ORDINARY SPUD WRENCH TO BRING THE PLIES INTO "FIRM" CONTACT, AND THEN AN ADDITIONAL 1/3 TURN (120° ± 30°) APPLIED TO THE NUT OR BOLT HEAD FOR FINAL BOLT TIGHTENING. A SYSTEMATIC APPROACH SHALL BE USED WHEN TIGHTENING THE BOLTS STARTING WITH THE MOST RIGID PART OF THE JOINT. THE PART NOT TURNED BY THE WRENCH SHALL BE
PREVENTED FROM ROTATING DURING THIS OPERATION.
3. IT IS ERI'S INTENTION THAT AN ANCO LOCKNUT BE PROVIDED FOR ALL HIGH-STRENGTH ASTM A325 BOLTED CONNECTIONS, UNLESS OTHERWISE NOTED. FLAT WASHERS ARE REQUIRED ON MOUNTING FLANGE CONNECTIONS.
4. UNLESS OTHERWISE NOTED, ALL ANTENNA MOUNTING FLANGE HARDWARE GRADES ARE AS FOLLOWS:
REV DESCRIPTION DATE APPROVED
A ADD FINAL DATA 6/6/2024 K. SCHARP
DRAWN BY
DRAFTING
DESIGN MGR.
40177/1
3/15/2024
3/22/2024
ESTABLISHED 1943
R
MECHANICAL PARAMETERS
CHANDLER, IN
47610-9219
40177 - BATON ROUGE, LA - CH. 25
and maintenance of ERI tower and antenna equipment, as appropriate. ALL DIMENSIONS ARE IN INCHES ANGULAR ± .5° EXT. APPROVAL SIZE CAGE CODE PM40177-1 REV.
Reproduction, transmission or disclosure to others, or unauthorized use, without the express written consent of ERI, is strictly prohibited.
UNAUTHORIZED DUPLICATION, REPRODUCTION, OR DISCLOSURE OF
THIS INFORMATION IS A VIOLATION OF FEDERAL LAW.
COPYRIGHT 2024 ERI, ELECTRONICS RESEARCH INC.
C:\Users\ggott\Documents\Vault\Designs\40177\1\PM40177-1.idwG.A.G.3/15/2024 3
AND APPLICABLE AT 20°C (68°F)
INTERPRET DIMENSIONS AND TOLERANCES
PER ASME Y14.5M-1994
FILE NAME: PM40177-1.idw
B
SCALE :
A
DWG NO.
TABLE
COMPONENT DESCRIPTION
STRUCTURAL BOLT ASTM A325 GALVANIZED
ANCO LOCKNUT ASTM A563 GRADE DH GALVANIZED HEAVY HEX NUT WITH STAINLESS PIN
FLAT WASHER ASTM F436 TYPE I GALVANIZED
23 1 66593 PRESSURE LABEL
22 1 ACX650-20 6-1/8" 50 OHM STANDARD INNER CONNECTOR
21 1 STRINPUT72-6.25-2.600 Ø6.25 STRAIGHT INPUT ADAPTER
20 1 ACX675B-17-1426 6" IMPEDANCE TRANSFORMER
19 1 ACX675-10SE 6 1/8" 90 DEG EQUAL LENGTH ELBOW
18 1 RLA675-16 6-1/8", 75 OHM GAS BARRIER
17 1 BTMSHT-6.25-1.711 6.25 75 OHM BOTTOM SHORT
16 1 43094 CABLE GRIP / HOISTING GRIP
15 1 69039 CLIMBING POLE GROUNDING KIT
14 1 165701 CABLE GRIP SUPPORT
13 1 9886-518 PIPE CAP REDUCER 2" TO 1"
12 4 SC1011Q0300ZIGR8 5/8-11 X 3 SQ. HEAD BOLT
11 16 SC2007H0700GA 1 1/4-7 x 7.00 in A325 Galv. Hex Bolt, 4" THREAD
10 16 NLA2007GA 1 1/4-7 GALV. ANCO LOCK NUT
9 32 WF20GA 1-1/4" FLAT WASHER F436 HDG STRUCTURAL
8 1 167423-18 SHIM KIT (NOT SHOWN)
7 4 LR0062-4800GA-N001 5/8"-11 X 48" 30 DEG BENT GALV W/2 NUT
6 4 LRK0007-KIT LIGHTNING SPUR HARDWARE KIT
5 12 LR0075-N003 LIGHTNING ROD ARRESTOR TIP
4 1 RLA650-450 6 1/8" to 4 1/16" REDUCER (50 OHM)
3 1 68157 6" INPUT HARDWARE KIT
2 1 RLA600-21 6-1/8" HARDWARE KIT
1 1 TA40177-1 Ø10.75 TOP LEVEL ASSEMBLY
ITEM QTY PART NUMBER DESCRIPTION
BOTTOM TOP
SEE DETAIL "C" ((469.95) BOTTOM OF MOUNTING FLANGE TO TOP OF TOP PLATE (42.00)
X
4-1/16" 50 OHM W
EIA INPUT
1" NPT FITTING FOR CUSTOMER
SUPPLIED CONDUIT & LIGHTING
CABLE (1" NPT FEMALE THREADS)
W
SEE DETAIL "A"
SEE DETAIL "B"
X
LIGHT NOT SUPPLIED
WITH ANTENNA
1" NPT FITTING FOR CUSTOMER
SUPPLIED CONDUIT & LIGHTING
2x
11 10 9 8
Ø12.00 THRU HOLE
16x Ø1.38 THRU FOR
Ø1.25 BOLTS EQUALLY
SPACED ON A Ø17.75 B.C.
CLIMBING POLE
CLIMBING POLE
15 13 14
Y
Y
CABLE (1" NPT FEMALE THREADS)
LIGHT NOT SUPPLIED
WITH ANTENNA
12 4x
REMOVE FIBERGLASS
INNER SUPPORT &
RE-INSTALL THREADED
PEG RETAINERS AFTER
ITEM #17 IS INSTALLED
REMOVE AFTER
INSTALLING ITEM #17
60° PEAK
Ø1.38 ALIGNMENT
BOLT HOLE @ 346°
60° PEAK
Ø1.38 ALIGNMENT
BOLT HOLE @ 346°
5 6 7
(2.00) TOWER
A TOP PLATE
MOUNTING SURFACE
SECTION W-W
SCALE 1/25
10 14
TOUNGE
SECTION X-X
SCALE 1/25 DETAIL B
DETAIL A
CUSTOMER SUPPLIED CABLE
DRAWN BY
40177/1
ESTABLISHED 1943
CHANDLER, IN
47610-9219
VIEW Y-Y
DRAFTING
DESIGN MGR.
40177 - BATON ROUGE, LA - CH. 25
and maintenance of ERI tower and antenna equipment, as appropriate. ALL DIMENSIONS ARE IN INCHES ANGULAR ± .5° EXT. APPROVAL SIZE CAGE CODE PM40177-1 REV.
Reproduction, transmission or disclosure to others, or unauthorized use, without the express written consent of ERI, is strictly prohibited.
UNAUTHORIZED DUPLICATION, REPRODUCTION, OR DISCLOSURE OF
THIS INFORMATION IS A VIOLATION OF FEDERAL LAW.
COPYRIGHT 2024 ERI, ELECTRONICS RESEARCH INC.
B
SCALE :
A
ANT
(98.01)
4-1/16" 50 OHM
EIA INPUT
(7.28)
4 2
9 8
22 21
(72.00) (13.24)
(5.50)
1 B
17 3
60.36
42.69
(2.00)
TOWER TOP
PLATE
DETAIL C
DRAWN BY
40177/1
ESTABLISHED 1943
R
7777 GARDNER Rd.
CHANDLER, IN
47610-9219
DRAFTING
DESIGN MGR.
40177 - BATON ROUGE, LA - CH. 25
and maintenance of ERI tower and antenna equipment, as appropriate. ALL DIMENSIONS ARE IN INCHES ANGULAR ± .5° EXT. APPROVAL SIZE CAGE CODE PM40177-1 REV.
Reproduction, transmission or disclosure to others, or unauthorized use, without the express written consent of ERI, is strictly prohibited.
UNAUTHORIZED DUPLICATION, REPRODUCTION, OR DISCLOSURE OF
THIS INFORMATION IS A VIOLATION OF FEDERAL LAW.
COPYRIGHT 2024 ERI, ELECTRONICS RESEARCH INC.
B
SCALE :
A
ANT
XM
SN
LINE
| Attachment D - Tower Details and Photos - Pages 1-14 |
| photo 1 |
| Attachment D - Pictures - Pages 1-12 |
| Antenna Manual |
| FIGURE #1 |
| REMOVAL FROM TRUCK |
| LIFT ANTENNA FROM TRUCK BED USING "YELLOW" ANTENNA LIFTING |
| PLATES, NOT THE RADOMES, AT THE LOCATIONS INDICATED. TO PREVENT ROLLING, LIFT FROM THE PLATES |
| SECTION W-W |
| DETAIL A |
| SEE DETAIL "A" W |
| W |
| ELECTRONICS RESEARCH INC. |
| TOLERANCES |
| LIFTING / SHIPPING DETAILS 40177 - BATON ROUGE, LA - CH. 25 |
| LD40177-1 |
| B |
| OZNS1 |
| A |
| 1 OF 4 |
| FIGURE #2 |
| LIFTING / SHIPPING DETAILS |
| TOLERANCES |
| 40177 - BATON ROUGE, LA - CH. 25 |
| LD40177-1 |
| B |
| OZNS1 |
| A |
| 2 OF 4 |
| FIGURE #3 |
| ELECTRONICS RESEARCH INC. |
| TOLERANCES |
| LIFTING / SHIPPING DETAILS 40177 - BATON ROUGE, LA - CH. 25 |
| LD40177-1 |
| B |
| OZNS1 |
| A |
| 3 OF 4 |
| FIGURE #4 |
| AFTER ANTENNA IS MOUNTED VERICALLY, REMOVE "YELLOW" LIFTING PLATES & HARDWARE. INSTALL ANTENNA RADOME COVERS. SEE DETAIL "A". |
| SEE DETAIL "A" ASSEMBILED RADOME SECTION |
| A DETAIL A |
| ELECTRONICS RESEARCH INC. |
| TOLERANCES |
| LIFTING / SHIPPING DETAILS 40177 - BATON ROUGE, LA - CH. 25 |
| LD40177-1 |
| B |
| OZNS1 |
| A |
| 4 OF 4 |
| ELECTRONICS RESEARCH INC. |
| MECHANICAL PARAMETERS |
| TOLERANCES |
| 40177 - BATON ROUGE, LA - CH. 25 |
| PM40177-1 |
| B |
| OZNS1 |
| A |
| 1 OF 3 |
| SEE DETAIL "C" |
| X |
| SEE DETAIL "A" |
| X |
| Y |
| SECTION W-W |
| SECTION X-X |
| DETAIL A |
| ELECTRONICS RESEARCH INC. |
| VIEW Y-Y |
| TOLERANCES |
| MECHANICAL PARAMETERS |
| PM40177-1 |
| B |
| OZNS1 |
| A |
| 2 OF 3 |
DETAIL C
| ELECTRONICS RESEARCH INC. |
| TOLERANCES |
| MECHANICAL PARAMETERS |
| PM40177-1 |
| B |
| OZNS1 |
| A |
File details come from the government source that posted it. Updated .