This is a tower inspection report and antenna installation documentation for a WLPB TV 990-foot tower inspection conducted on August 18, 2025, related to a transmission line installation project for Louisiana's LETA (Louisiana Educational Television Authority). The file contains detailed section-by-section inspection findings documenting structural deficiencies, maintenance issues, and equipment problems throughout the tower, including loose and improperly routed flexible transmission lines, missing hangers across multiple sections (sections 5, 6, 10, 11, 12, 13, 18), bent and damaged horizontal members (section 15), damaged diagonal members (section 39), improperly secured Kellum grips, rust on safety climb cable systems, and a missing safety climb system on the transition climbing ladder from bay 1 through bay 4. The documentation also includes photographs illustrating typical views of identified deficiencies and mechanical specifications for a cascade antenna assembly (project 40177) manufactured by Electronics Research Inc., detailing lifting procedures, shipping details, mounting specifications, and connection requirements for a 4,400-pound antenna system designed for installation on the tower top plate.

The inspection report provides detailed photographic evidence and technical specifications necessary for remediation planning and antenna installation coordination. The antenna installation documentation includes comprehensive lifting and shipping details with specific rigging attachment points, mounting flange specifications, torque requirements for hardware assembly, and plumbing tolerances requiring the antenna to be within 0.1 degrees from vertical. Bill of materials and mechanical parameter drawings specify hardware grades (ASTM A325 bolts, ANCO locknuts, F436 flat washers), cable specifications, grounding kits, lightning protection components, and climbing pole assemblies. The contract appears to address tower maintenance, repair of identified structural and transmission line deficiencies, and installation of updated antenna equipment to restore the transmission facility to proper operational standards.

View the file

Other files

File Type Posted
3000026811.pdf PDF
Attachment B - Job Site Verification Form - Page 1.docx DOCX document
Attachment C - Specifications - Page 1.docx DOCX document
Attachment A - Special Terms and Conditions Pages 1-15.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WLPB TV 990’ Tower Inspection

August 18th, 2025

TOWER SECTION DETAIL

This section of the report details any problems with the structural condition, flexible transmission lines, paint, lighting/conduit systems, ladder, or safety climb equipment, rusting, or side mounted antenna problems. The format is “section-by-section” numbering from the ground up. The first vertical section is #1.

List Section # Details

Typical There are loose and improperly routed flexible transmission lines through-out the horizontal bridge and tower.

Section #5 There are (3) missing hangers for the EW63 flexible transmission line.

Section #6 There are (4) missing hangers for the 3” flexible transmission line.

Section #7 There is (1) kinked flex jumper for the two-way type of antenna on the #2.

Section #8 There is (1) improperly secured ground for the 3” flexible transmission line.

Section #10 There are (3) missing hangers for the 3” flexible transmission line.

Section #11 There are (4) missing hangers for the 3” flexible transmission line.

Section #12 There are (4) missing hangers for the 3” flexible transmission line.

Section #13 There is (1) missing hanger for the 3” flexible transmission line in bay #2.

Section #15 There is (1) bent horizontal member on the x-face in bay #2.

Section #17 There is (1) damaged flexible transmission line grounding in bay #3.

There is (1) missing hanger for the 3” flexible transmission line in bay #3.

Section #18 There are (5) missing hangers for the 7/8” flexible transmission line in bay

#2. There are (3) missing hangers for the 3” flexible transmission line.

Section #20 There is (1) unsecured flex jumper on the a-leg.

Section #21 There are (2) improperly secured Kellum grips for the 7/8” flexible trans-mission lines.

Section #23 There is (1) missing ground for the flexible transmission line in bay #2.

Section #28 There is (1) improperly secured Kellum grip in bay #3.

Section #32 There is (1) missing ground for the 1-1/4” flexible transmission line

There is (1) improperly secured Kellum grip in bay #2.

Section #33 There is (1) abandoned 2-bay FM antenna on the c-leg.

Section #35 There is (1) improper ground for the 3” flexible transmission line in bay

#2.

Section #39

There are (2) damaged diagonal members on the x-face in bay #2. There is (1) abandoned hanger in bay #4. There is no safety climb on the transi-tion ladder from bay #1 through #4.

Attachment D - Tower Details and Photos RFx: 300026811

TOWER CROSS SECTION DRAWING

PHOTOGRAPHS

The upper photo shows a typical view of the bent horizontal member in section #15. The lower photo shows a typical view of the (2) damaged diagonal members in section #39.

PHOTOGRAPHS

The photo shows a typical view of no personnel safety climb system on the transition climbing ladder at the tower top.

PHOTOGRAPHS

The photos show typical views of the improperly mounted upper bracket of the safety climb system on the main climbing ladder.

PHOTOGRAPHS

The photos show typical views of the medium to heavy surface rust on the personnel ladder safety climb cable.

PHOTOGRAPHS

The photos show typical views of the (3) flexible transmission lines secured to the main climbing ladder.

PHOTOGRAPHS

The photo shows a typical view of loose and improperly installed flexible transmission lines.

PHOTOGRAPHS

The upper photo shows a typical view of improper Kellum grips for flexible transmission lines.

The lower photo shows a typical view of a missing Kellum grip for flexible transmission lines.

PHOTOGRAPHS

The left photo shows a typical view of a missing Kellum grip for flexible transmission lines. The right photo shows a typical view of improper Kellum grips for flexible transmission lines.

PHOTOGRAPHS

The photos show typical views of loose and improperly installed flexible transmission lines.

PHOTOGRAPHS

The photos show the kinked flex jumper for the dish antenna in section #7.

PHOTOGRAPHS

The upper photo shows a typical view of the abandoned hanger in section #39. The lower photo shows a typical view of the abandoned 2-bay FM in section #33.

PHOTOGRAPHS

The upper photo shows a typical view of the AOL and lightning arrester system on the top mounted TV antenna. The lower photo shows a typical view of the top mounted TV antenna.

VE

R

TI

CA

L O

N

LY

4 3

FIGURE #1

2 1

REVISION HISTORY

REMOVAL FROM TRUCK

2x 1

LIFTING SHACKLE

REV DESCRIPTION DATE APPROVED

A ADD FINAL DATA 6/6/2024 K. SCHARP

LIFT ANTENNA FROM TRUCK BED USING "YELLOW" ANTENNA LIFTING 4x 4x 4x

PLATES, NOT THE RADOMES, AT THE LOCATIONS INDICATED.

TO PREVENT ROLLING, LIFT FROM THE PLATES

AS SHOWN IN VIEW "W-W". DO NOT LIFT ANTENNA

BY RADOMES, DAMAGE WILL OCCUR.

NOTES:

4 3 2

(25.00)

LIFTING SHACKLE

2 3 4

B 1. THE LIFTING DETAILS PROVIDED IDENTIFY THE PRIMARY RIGGING ATTACHMENT POINTS ON

THE ANTENNA FOR DELIVERY LOADING/UNLOADING, UPENDING, AND HOISTING OPERATIONS.

2. ALL RIGGING COMPONENTS SHALL BE PROPERLY SELECTED AND SIZED BY THE

CONTRACTOR'S QUALIFIED PERSON TO ENSURE THE COMPONENTS ARE UTILIZED IN

ACCORDANCE WITH RIGGING MANUFACTURER'S WLL LIMITS AND ASSOCIATED SPECIFICATIONS.

3. CONTACT ERI FOR REVIEW AND APPROVAL IF ALTERNATE RIGGING ATTACHMENT POINTS

ARE NEEDED FOR HANDLING OR HOISTING OPERATIONS.

(478.42) O.A.L.

SECTION W-W

SCALE 1/10

X (Ø18.18)

DO NOT PUSH ON RADOME

ALONG DATUM X

B

DETAIL A

(TYP.)

SCALE 1/8

12.00 289.30

(ANTENNA WEIGHT = 4,400 LBS)

SEE DETAIL "A" W

.00

TRUCK BED WOOD LEVELING BLOCK W

301.65

WOOD LEVELING BLOCK

469.70

(MTG. SURFACE)

A

LIFTING PLATE PLATE

TITLE:

ELECTRONICS RESEARCH INC.

ESTABLISHED 1943

R

7777 GARDNER Rd.

CHANDLER, IN

47610-9219

PHONE: (812) 925-6000

FAX: (812) 925-4030

This document/drawing contains information considered confidential by Electronics Research, Inc. ("ERI"). This information is disclosed on a confidential basis and only authorized for use in the installation, operation, THIRD ANGLE PROJECTION

MATERIAL

FINISH

TOLERANCES

OVERALL-NOT CUMULATIVE

UNLESS OTHERWISE SPECIFIED,

1 PLACE DECIMAL ± .1

2 PLACE DECIMAL ± .03 3 PLACE DECIMAL ± .010

MANUF.

LIFTING / SHIPPING DETAILS

40177 - BATON ROUGE, LA - CH. 25

and maintenance of ERI tower and antenna equipment, as appropriate. ALL DIMENSIONS ARE IN INCHES ANGULAR ± .5° EXT. APPROVAL SIZE CAGE CODE LD40177-1 REV.

Reproduction, transmission or disclosure to others, or unauthorized use, without the express written consent of ERI, is strictly prohibited.

UNAUTHORIZED DUPLICATION, REPRODUCTION, OR DISCLOSURE OF

THIS INFORMATION IS A VIOLATION OF FEDERAL LAW.

COPYRIGHT 2023 ERI, ELECTRONICS RESEARCH INC.

C:\Users\ggott\Documents\Vault\Designs\40177\1\LD40177-1.idwggott3/18/2024 3

AND APPLICABLE AT 20°C (68°F)

INTERPRET DIMENSIONS AND TOLERANCES

PER ASME Y14.5M-1994

FRACTIONAL ± 1/16"

LEG HOLE -0", +1/16"

SUPERSEDES PART NO.

FILE NAME: LD40177-1.idw

B

SCALE :

OZNS1

AS NOTED

WEIGHT: SHEET:

N/A

A

LI

FT

L

IF

T

VE

R

TI

CA

L

O N

LY

DWG NO.

4 4 NU1210GA 3/4 - 10 GALV. HEX NUT

3 4 WF12GA 3/4" FLAT WASHER F436 HDG STRUCTURAL

2 4 SC1210H0300GA 3/4 - 10 x 3.00 LG (1.38" MIN THREADS) A325 BOLT

1 2 LLTRIUP001 "YELLOW" LIFTING LUG FOR CASCADE ANTENNA

TEM QTY PART NUMBER DESCRIPTION

BILL OF MATERIAL

PROJECT NO. 40177/1

ERI APPROVAL NAME DATE

DRAWN BY G.A.G. 3/18/2024

DRAFTING

DESIGN MGR. K. SCHARP 3/28/2024

ENG. J.H. 4/3/2024

4 3 2 1

FIGURE #2

PLACE ANTENNA WOODEN SUPPORTS AS SHOWN.

ANTENNA SHOULD BE LEVEL TO PREVENT DAMAGE.

USE SUPPORTS HIGH ENOUGH TO AVOID DAMAGING THE RADOMES AND TO ALLOW FOR

ELECTRICAL GROUND TEST OF THE ANTENNA. PLATES RESTING 6.0 INCHES ABOVE

THE GROUND IS SUFFICIENT.

B B

WOOD SUPPORTS

GROUND TO LEVEL ANTENNA

WOOD SUPPORTS

TO LEVEL ANTENNA

A A

PROJECT NO.

ERI APPROVAL

DRAWN BY

DRAFTING

DESIGN MGR.

40177/1

NAME

G.A.G.

K. SCHARP

DATE

3/18/2024

3/28/2024

7777 GARDNER Rd.

CHANDLER, IN

47610-9219

ENG.

J.H. 4/3/2024 40177 - BATON ROUGE, LA - CH. 25

and maintenance of ERI tower and antenna equipment, as appropriate. ALL DIMENSIONS ARE IN INCHES ANGULAR ± .5° EXT. APPROVAL SIZE CAGE CODE LD40177-1 REV.

Reproduction, transmission or disclosure to others, or unauthorized use, without the express written consent of ERI, is strictly prohibited.

UNAUTHORIZED DUPLICATION, REPRODUCTION, OR DISCLOSURE OF

THIS INFORMATION IS A VIOLATION OF FEDERAL LAW.

COPYRIGHT 2023 ERI, ELECTRONICS RESEARCH INC.

AND APPLICABLE AT 20°C (68°F)

INTERPRET DIMENSIONS AND TOLERANCES

PER ASME Y14.5M-1994

B

SCALE :

A

FIGURE #3

WHEN LIFTING THE ANTENNA FOR INSTALLATION, LIFT AS SHOWN TO

PREVENT DAMAGE TO THE BASE OF THE ANTENNA. WHEN THE ANTENNA

IS VERTICAL, THE ADDITIONAL BASE LIFTING CABLE CAN BE REMOVED.

NOTE: THIS ILLUSTRATION IS INTENDED TO SHOW A CONCEPT FOR

LIFTING THE ERI INC. TRASAR ANTENNA TO PREVENT DAMAGE TO THE

ANTENNA AND THE RADOMES. SAFE AND PROPER IMPLEMENTATION OF

THIS CONCEPT ARE THE RESPONSIBILITY OF THE INSTALLER.

MAIN LIFTING CABLE

ADDITIONAL LIFTING CABLE

ATTACH MAIN

LIFTING CABLES

TO LIFTING PLATES

DRAWN BY

40177/1

NAME

3/18/2024

ESTABLISHED 1943

R

7777 GARDNER Rd.

CHANDLER, IN

47610-9219

DRAFTING

DESIGN MGR.

J.H.

3/28/2024

4/3/2024

LIFTING / SHIPPING DETAILS

40177 - BATON ROUGE, LA - CH. 25

and maintenance of ERI tower and antenna equipment, as appropriate. ALL DIMENSIONS ARE IN INCHES ANGULAR ± .5° EXT. APPROVAL SIZE CAGE CODE LD40177-1 REV.

Reproduction, transmission or disclosure to others, or unauthorized use, without the express written consent of ERI, is strictly prohibited.

UNAUTHORIZED DUPLICATION, REPRODUCTION, OR DISCLOSURE OF

THIS INFORMATION IS A VIOLATION OF FEDERAL LAW.

COPYRIGHT 2023 ERI, ELECTRONICS RESEARCH INC.

B

SCALE :

A

FIGURE #4

AFTER ANTENNA IS MOUNTED VERICALLY, REMOVE "YELLOW" LIFTING PLATES & HARDWARE.

INSTALL ANTENNA RADOME COVERS. SEE DETAIL "A".

REMOVE "YELLOW" LIFTING

PLATE & HARDWARE

SEE DETAIL "A"

ASSEMBILED RADOME SECTION

SCALE 1/15

4x 4x 4x 4x

4 5 6 8

NOTE:

1 TORQUE 1/4" HARDWARE

TO 6 FT/LBS

A DETAIL A

(TYP. EACH SIDE)

SCALE 1 / 5

10x 10x 10x 10x 10x

3 4 5 6 7

ITEM

QTY

PART NUMBER

DESCRIPTION

7777 GARDNER Rd.

REMOVE "YELLOW" LIFTING

PLATE & HARDWARE

TOWER TOP

PLATE

ESTABLISHED 1943

R

CHANDLER, IN

47610-9219

40177 - BATON ROUGE, LA - CH. 25

and maintenance of ERI tower and antenna equipment, as appropriate. ALL DIMENSIONS ARE IN INCHES ANGULAR ± .5° EXT. APPROVAL SIZE CAGE CODE LD40177-1 REV.

Reproduction, transmission or disclosure to others, or unauthorized use, without the express written consent of ERI, is strictly prohibited.

UNAUTHORIZED DUPLICATION, REPRODUCTION, OR DISCLOSURE OF

THIS INFORMATION IS A VIOLATION OF FEDERAL LAW.

COPYRIGHT 2023 ERI, ELECTRONICS RESEARCH INC.

B

SCALE :

A

DWG NO.

8 8 RW001 RADOME WASHER

7 20 WF05.5SS FLATWASHER, SS

6 24 WL04SS 1/4 in, SS LOCK WASHER 5 28 WF04SS 1/4 in, SS FLAT WASHER 4 28 SC0420H0087 1/4-20 UNC x 0.875 in, SST HEX BOLT

3 20 RTN0003 RIVET NUT

2 1 RAUN40177-2-OR UNPRESSURIZED CASCADE RADOME COVER (Ø18")

1 1 RAUN40177-6-OR UNPRESSURIZED CASCADE RADOME COVER (Ø18")

PROJECT NO. 40177/1

ERI APPROVAL NAME DATE

DRAWN BY G.A.G. 3/18/2024

DRAFTING

DESIGN MGR. K. SCHARP 3/28/2024

ENG. J.H. 4/3/2024

NOTES:

3 2 1

REVISION HISTORY

1. REMOVE ALL BURRS AND SHARP EDGES.

2. LOC-TITE ALL THREADS PER BOP 2.02.01.

3. TORQUE ALL 1/4" HARDWARE TO 6 FT/LBS.

4. TORQUE ALL 5/8" HARDWARE TO 60-65 FT/LBS.

5. TORQUE ALL 1/2" HARDWARE TO 50-65 FT/LBS.

6. TORQUE ALL 3/8" HARDWARE TO 28 FT/LBS.

B 7. ALL EXTERIOR HARDWARE TO BE ASSEMBLED WITH THE HEAD OF THE BOLT TOWARDS THE BOTTOM OF THE ANTENNA.

8. USE SMALL ERI SHIPPING LABEL WHERE NOTED.

9. USING BLACK PAINT, STENCIL AS SHOWN, USING MIN. 1/2" HIGH CHARACTERS.

10. BEND TONGUE OF CABLE GRIP SUPPORT (ITEM #14) TO CAPTIVATE THE CABLE GRIP.

11. APPLY TEFLON TAPE TO THREADS ON TOP OF CLIMBING POLE.

CONNECTION NOTES:

1. FOR PROPER PERFORMANCE AFTER INSTALLATION, PLUMB THE ANTENNA TO WITHIN 0.1°

FROM VERTICAL (5/8 INCH IN 30 FEET). A KIT OF SHIMS IS INCLUDED WITH THE ANTENNA.

AS REQUIRED FOR PROPER PLUMB, GAPS BETWEEN ANTENNA MOUNTING FLANGE AND TOWER

TOP PLATE MUST BE FILLED USING THE SUPPLIED SHIM KIT OR SUITABLE STEEL SHIM STOCK.

2. ANTENNA MOUNTING FLANGE BOLTED CONNECTION SHALL BE BROUGHT TO A SNUG-TIGHT CONDITION

WHERE JOINT TIGHTNESS IS ATTAINED WITH A FEW IMPACTS OF AN IMPACT WRENCH OR FULL EFFORT OF AN IRONWORKER USING AN ORDINARY SPUD WRENCH TO BRING THE PLIES INTO "FIRM" CONTACT, AND THEN AN ADDITIONAL 1/3 TURN (120° ± 30°) APPLIED TO THE NUT OR BOLT HEAD FOR FINAL BOLT TIGHTENING. A SYSTEMATIC APPROACH SHALL BE USED WHEN TIGHTENING THE BOLTS STARTING WITH THE MOST RIGID PART OF THE JOINT. THE PART NOT TURNED BY THE WRENCH SHALL BE

PREVENTED FROM ROTATING DURING THIS OPERATION.

3. IT IS ERI'S INTENTION THAT AN ANCO LOCKNUT BE PROVIDED FOR ALL HIGH-STRENGTH ASTM A325 BOLTED CONNECTIONS, UNLESS OTHERWISE NOTED. FLAT WASHERS ARE REQUIRED ON MOUNTING FLANGE CONNECTIONS.

4. UNLESS OTHERWISE NOTED, ALL ANTENNA MOUNTING FLANGE HARDWARE GRADES ARE AS FOLLOWS:

REV DESCRIPTION DATE APPROVED

A ADD FINAL DATA 6/6/2024 K. SCHARP

DRAWN BY

DRAFTING

DESIGN MGR.

40177/1

3/15/2024

3/22/2024

ESTABLISHED 1943

R

MECHANICAL PARAMETERS

CHANDLER, IN

47610-9219

40177 - BATON ROUGE, LA - CH. 25

and maintenance of ERI tower and antenna equipment, as appropriate. ALL DIMENSIONS ARE IN INCHES ANGULAR ± .5° EXT. APPROVAL SIZE CAGE CODE PM40177-1 REV.

Reproduction, transmission or disclosure to others, or unauthorized use, without the express written consent of ERI, is strictly prohibited.

UNAUTHORIZED DUPLICATION, REPRODUCTION, OR DISCLOSURE OF

THIS INFORMATION IS A VIOLATION OF FEDERAL LAW.

COPYRIGHT 2024 ERI, ELECTRONICS RESEARCH INC.

C:\Users\ggott\Documents\Vault\Designs\40177\1\PM40177-1.idwG.A.G.3/15/2024 3

AND APPLICABLE AT 20°C (68°F)

INTERPRET DIMENSIONS AND TOLERANCES

PER ASME Y14.5M-1994

FILE NAME: PM40177-1.idw

B

SCALE :

A

DWG NO.

TABLE

COMPONENT DESCRIPTION

STRUCTURAL BOLT ASTM A325 GALVANIZED

ANCO LOCKNUT ASTM A563 GRADE DH GALVANIZED HEAVY HEX NUT WITH STAINLESS PIN

FLAT WASHER ASTM F436 TYPE I GALVANIZED

23 1 66593 PRESSURE LABEL

22 1 ACX650-20 6-1/8" 50 OHM STANDARD INNER CONNECTOR

21 1 STRINPUT72-6.25-2.600 Ø6.25 STRAIGHT INPUT ADAPTER

20 1 ACX675B-17-1426 6" IMPEDANCE TRANSFORMER

19 1 ACX675-10SE 6 1/8" 90 DEG EQUAL LENGTH ELBOW

18 1 RLA675-16 6-1/8", 75 OHM GAS BARRIER

17 1 BTMSHT-6.25-1.711 6.25 75 OHM BOTTOM SHORT

16 1 43094 CABLE GRIP / HOISTING GRIP

15 1 69039 CLIMBING POLE GROUNDING KIT

14 1 165701 CABLE GRIP SUPPORT

13 1 9886-518 PIPE CAP REDUCER 2" TO 1"

12 4 SC1011Q0300ZIGR8 5/8-11 X 3 SQ. HEAD BOLT

11 16 SC2007H0700GA 1 1/4-7 x 7.00 in A325 Galv. Hex Bolt, 4" THREAD

10 16 NLA2007GA 1 1/4-7 GALV. ANCO LOCK NUT

9 32 WF20GA 1-1/4" FLAT WASHER F436 HDG STRUCTURAL

8 1 167423-18 SHIM KIT (NOT SHOWN)

7 4 LR0062-4800GA-N001 5/8"-11 X 48" 30 DEG BENT GALV W/2 NUT

6 4 LRK0007-KIT LIGHTNING SPUR HARDWARE KIT

5 12 LR0075-N003 LIGHTNING ROD ARRESTOR TIP

4 1 RLA650-450 6 1/8" to 4 1/16" REDUCER (50 OHM)

3 1 68157 6" INPUT HARDWARE KIT

2 1 RLA600-21 6-1/8" HARDWARE KIT

1 1 TA40177-1 Ø10.75 TOP LEVEL ASSEMBLY

ITEM QTY PART NUMBER DESCRIPTION

BOTTOM TOP

SEE DETAIL "C" ((469.95) BOTTOM OF MOUNTING FLANGE TO TOP OF TOP PLATE (42.00)

X

4-1/16" 50 OHM W

EIA INPUT

1" NPT FITTING FOR CUSTOMER

SUPPLIED CONDUIT & LIGHTING

CABLE (1" NPT FEMALE THREADS)

W

SEE DETAIL "A"

SEE DETAIL "B"

X

LIGHT NOT SUPPLIED

WITH ANTENNA

1" NPT FITTING FOR CUSTOMER

SUPPLIED CONDUIT & LIGHTING

2x

11 10 9 8

Ø12.00 THRU HOLE

16x Ø1.38 THRU FOR

Ø1.25 BOLTS EQUALLY

SPACED ON A Ø17.75 B.C.

CLIMBING POLE

CLIMBING POLE

15 13 14

Y

Y

CABLE (1" NPT FEMALE THREADS)

LIGHT NOT SUPPLIED

WITH ANTENNA

12 4x

REMOVE FIBERGLASS

INNER SUPPORT &

RE-INSTALL THREADED

PEG RETAINERS AFTER

ITEM #17 IS INSTALLED

REMOVE AFTER

INSTALLING ITEM #17

60° PEAK

Ø1.38 ALIGNMENT

BOLT HOLE @ 346°

60° PEAK

Ø1.38 ALIGNMENT

BOLT HOLE @ 346°

5 6 7

(2.00) TOWER

A TOP PLATE

MOUNTING SURFACE

SECTION W-W

SCALE 1/25

10 14

TOUNGE

SECTION X-X

SCALE 1/25 DETAIL B

DETAIL A

CUSTOMER SUPPLIED CABLE

DRAWN BY

40177/1

ESTABLISHED 1943

CHANDLER, IN

47610-9219

VIEW Y-Y

DRAFTING

DESIGN MGR.

40177 - BATON ROUGE, LA - CH. 25

and maintenance of ERI tower and antenna equipment, as appropriate. ALL DIMENSIONS ARE IN INCHES ANGULAR ± .5° EXT. APPROVAL SIZE CAGE CODE PM40177-1 REV.

Reproduction, transmission or disclosure to others, or unauthorized use, without the express written consent of ERI, is strictly prohibited.

UNAUTHORIZED DUPLICATION, REPRODUCTION, OR DISCLOSURE OF

THIS INFORMATION IS A VIOLATION OF FEDERAL LAW.

COPYRIGHT 2024 ERI, ELECTRONICS RESEARCH INC.

B

SCALE :

A

ANT

(98.01)

4-1/16" 50 OHM

EIA INPUT

(7.28)

4 2

9 8

22 21

(72.00) (13.24)

(5.50)

1 B

17 3

60.36

42.69

(2.00)

TOWER TOP

PLATE

DETAIL C

DRAWN BY

40177/1

ESTABLISHED 1943

R

7777 GARDNER Rd.

CHANDLER, IN

47610-9219

DRAFTING

DESIGN MGR.

40177 - BATON ROUGE, LA - CH. 25

and maintenance of ERI tower and antenna equipment, as appropriate. ALL DIMENSIONS ARE IN INCHES ANGULAR ± .5° EXT. APPROVAL SIZE CAGE CODE PM40177-1 REV.

Reproduction, transmission or disclosure to others, or unauthorized use, without the express written consent of ERI, is strictly prohibited.

UNAUTHORIZED DUPLICATION, REPRODUCTION, OR DISCLOSURE OF

THIS INFORMATION IS A VIOLATION OF FEDERAL LAW.

COPYRIGHT 2024 ERI, ELECTRONICS RESEARCH INC.

B

SCALE :

A

ANT

XM

SN

LINE

Attachment D - Tower Details and Photos - Pages 1-14
photo 1
Attachment D - Pictures - Pages 1-12
Antenna Manual
FIGURE #1
REMOVAL FROM TRUCK
LIFT ANTENNA FROM TRUCK BED USING "YELLOW" ANTENNA LIFTING
PLATES, NOT THE RADOMES, AT THE LOCATIONS INDICATED. TO PREVENT ROLLING, LIFT FROM THE PLATES
SECTION W-W
DETAIL A
SEE DETAIL "A" W
W
ELECTRONICS RESEARCH INC.
TOLERANCES
LIFTING / SHIPPING DETAILS 40177 - BATON ROUGE, LA - CH. 25
LD40177-1
B
OZNS1
A
1 OF 4
FIGURE #2
LIFTING / SHIPPING DETAILS
TOLERANCES
40177 - BATON ROUGE, LA - CH. 25
LD40177-1
B
OZNS1
A
2 OF 4
FIGURE #3
ELECTRONICS RESEARCH INC.
TOLERANCES
LIFTING / SHIPPING DETAILS 40177 - BATON ROUGE, LA - CH. 25
LD40177-1
B
OZNS1
A
3 OF 4
FIGURE #4
AFTER ANTENNA IS MOUNTED VERICALLY, REMOVE "YELLOW" LIFTING PLATES & HARDWARE. INSTALL ANTENNA RADOME COVERS. SEE DETAIL "A".
SEE DETAIL "A" ASSEMBILED RADOME SECTION
A DETAIL A
ELECTRONICS RESEARCH INC.
TOLERANCES
LIFTING / SHIPPING DETAILS 40177 - BATON ROUGE, LA - CH. 25
LD40177-1
B
OZNS1
A
4 OF 4
ELECTRONICS RESEARCH INC.
MECHANICAL PARAMETERS
TOLERANCES
40177 - BATON ROUGE, LA - CH. 25
PM40177-1
B
OZNS1
A
1 OF 3
SEE DETAIL "C"
X
SEE DETAIL "A"
X
Y
SECTION W-W
SECTION X-X
DETAIL A
ELECTRONICS RESEARCH INC.
VIEW Y-Y
TOLERANCES
MECHANICAL PARAMETERS
PM40177-1
B
OZNS1
A
2 OF 3

DETAIL C

ELECTRONICS RESEARCH INC.
TOLERANCES
MECHANICAL PARAMETERS
PM40177-1
B
OZNS1
A

File details come from the government source that posted it. Updated .