Attachment C Price Cost Delivey Schedule.pdf
PDF 141 KB Posted
- Attached to
- 4120--Vertical AC Units Federal contract opportunity
- Solicitation number
- 36C24820Q1235
About this file
This document is an attachment to a solicitation providing pricing details for replacing twenty-five vertical air conditioning units at the Malcom Randall VA Medical Center in Gainesville, Florida. The solicitation seeks to replace units across seven trailers on site, with specifications provided for each replacement. Pricing is listed by item number for replacing two units in Trailer T-8, five units in Trailer T-6, four units in Trailer T-2, five units in Trailer T-1B, six units across Trailers T-1A and T-9, and five units in Trailer T-5, for a total of twenty-five new vertical package dehumidifier units to match existing capacity ratings. A grand total price is to be provided in the schedule along with proposed delivery dates for each replacement item.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24820Q1235_3.docx | DOCX document | |
| 36C24820Q1235_2.docx | DOCX document | |
| Attachment C Price Cost Delivey Schedule - Amended.pdf | ||
| Attachment B Statement of Need - Amended.pdf | ||
| Attachment B Statement of Need.pdf | ||
| 36C24820Q1235.docx | DOCX document | |
| Attachment A Combined Synopsis Solicitation SDVOSB.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PRICE/COST/DELIVERY SCHEDULE
36C24820Q1235
PRICE/COST/DELIVERY SCHEDULE
ITEM INFORMATION
ITEM
NUMBER
DESCRIPTION OF
SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
1.00 JB __________________ __________________
REPLACE TRAILER T-8 VERTICAL PACKAGE UNIT AIR CONDITIONERS - A qualified contractor must be brought in to: Provide "turn-key" replacement of two (2) existing three (3) ton Bard vertical Package units with new dehumidification capable three (3) ton vertical package units.
REPLACE TRAILER T-6 VERTICAL PACKAGE UNIT AIR CONDITIONERS - A qualified contractor must be brought in to: Provide "turn-key" replacement of five (5) existing three (3) ton vertical package unit air conditioners with new dehumidification capable vertical package units of the same capacity.
REPLACE TRAILER T-2 VERTICAL PACKAGE UNIT AIR CONDITIONERS - A qualified contractor must be brought in to: Provide "turn-key" replacement of four (4) existing four (4) ton Bard vertical Package units with new dehumidification capable four (4) ton vertical package units.
REPLACE TRAILER T-1B VERTICAL PACKAGE UNIT AIR CONDITIONERS. A
QUALIFIED CONTRACTOR MUST BE BROUGHT IN TO: Provide "turn-key" replacement of five (5) existing vertical package unit air conditioners (two (2) two and a half (2.5) ton vertical package units and two (2) three (3) ton vertical package units and one (1) three and a half (3.5) ton vertical package unit) with new dehumidification capable vertical package units of the same capacity.
REPLACE TRAILER T-1A AND T-9 VERTICAL PACKAGE UNIT AIR CONDITIONERS - A
qualified contractor must be brought in to: Provide "turn-key" replacement of three (3) existing two and a half (2.5) ton Bard vertical Package units installed on T-1A and three (3) existing four (4) ton Bard vertical Package units installed on T-9 with new dehumidification capable vertical package units of the same capacity.
REPLACE TRAILER T-5 VERTICAL PACKAGE UNIT AIR CONDITIONERS - A qualified contractor must be brought in to: Provide "turn-key" replacement of five (5) existing three and a half (3.5) ton Bard vertical Package units with new dehumidification capable three and a half (3.5) ton vertical package units.
GRAND TOTAL __________________
PRICE/COST/DELIVERY SCHEDULE
36C24820Q1235
DELIVERY
ITEM NUMBER QUANTITY DELIVERY DATE
1.00
File details come from the government source that posted it. Updated .