Attachment_A_MIMA_Identity_Sign_Drawings.pdf

PDF 1 MB Posted

Attached to
MIMA SIGN FABRICATION Federal contract opportunity
Solicitation number
140P2123Q0162
Issued by
Department of the Interior National Park Service

About this file

This document contains drawings and specifications for identity signs for facilities at Minute Man National Historical Park. The National Park Service solicitation seeks fabrication and installation of 16 private residence signs, 2 parking control signs, and identity signs for 26 park facilities. Sign designs include single-sided and double-sided aluminum panels with direct digital printing, as well as stone monoliths. Specifications cover sign dimensions, materials, mounting locations, lettering size and other details. The related solicitation is for the sign fabrication work with the Department of Interior National Park Service as the contracting agency.

View the file

Other files for this federal contract opportunity

Other files attached to MIMA SIGN FABRICATION, newest first.
File Type Posted
Attachment_B_MIMA_Fabrication_Intent_Details.pdf PDF
Attachment_D_MIMA_Park_Map.pdf PDF
Attachment_C_MIMA_Sign_Location_Information.pdf PDF
Sol_140P2123Q0162.pdf PDF
Attachment_E_-_Pricing_Sheet.xls XLS spreadsheet

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Harpers Ferry Center Harpers Ferry, WV 25425

MIMA-2022-1392

May 25, 2023

Identity Signs Drawings

Minute Man National

Historical Park

Attachment A

National Park Service | Harpers Ferry Center | Media Development | Signs

Project Number

Drawing Date Pa g e

1.0 Identity Sign Project

MIMA-2022-1392-ID

11-02-2022

Minute Man National Historical Park

Private Residence

Reserved Parking Private Residence Parking Only

Colonel James Barrett House and Farm

National Park Service U.S. Department of the Interior

Minute Man National Historical Park

Circa 1705

Reserved Parking Private Residence Parking Only

PRIVATE

RESIDENCE

PR 1.0 - 16.0 - Facility Identity Private Residence - QTY: 16

Scale: 1-1/2” = 1” - 0” and 1/4” = 1” - 0” Direct print aluminum panel

Facility Identity Signs that also have a private residence panel will also have a separate Private Residence sign near the front door.

Cap Height: 1-1/2” - 12” x 6” Back - Color to Match Post

9” x 15” Back - Color to Match Post

PC 1.0 - 2.0 - Parking Control - Qty: 2

Scale: 1-1/2” = 1” - 0” and 1/4” = 1” - 0” Low Intensity Retro-Reflective Vinyl on Aluminum Panels

ID 1.0 - Facility Identity Scale: 1” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS double sided frame with each panel printed double sided - direct print aluminum panel Installed perpendicular to the road

2” Cap Height - 36” x 18” 2 double sided panels - Front and back of each panel are the same

Major John Buttrick House

National Park Service U.S. Department of the Interior

Minute Man National Historical Park

Circa 1715

PRIVATE RESIDENCE

ID 2.0 - Facility Identity Scale: 1” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS single sided with 2 frames with panels printed double sided - direct print aluminum panel Installed parallel to the road

2” Cap Height - 30” x 18” 1 double sided panel - Front and back of panel are the same

30” x 6”

Front

Back

Drawing Date Pa g e

2.0 Identity Sign Project

MIMA-2022-1392-ID

11-02-2022

Minute Man National Historical Park

54” x 42” 1 double sided panel - Front and back of panel are the same

4” Cap Height - 68” x 32”

Front

Back

National Park Service U.S. Department of the Interior

North Bridge Minute Man National Historical Park

North Bridge Visitor Center

National Park Service U.S. Department of the Interior

Minute Man National Historical Park and Park Headquarters

National Park Service U.S. Department of the Interior

North Bridge Minute Man National Historical Park

ID 4.0 - Facility Identity Scale: 3/4” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS single sided frame with panel printed double sided - direct print aluminum panel Installed in previous location

Elisha Jones House

National Park Service U.S. Department of the Interior

Minute Man National Historical Park

Circa 1740

ID 6.0 - Facility Identity Scale: 1” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS single sided with 2 frames with panels printed double sided - direct print aluminum panel Installed parallel to the road PRIVATE RESIDENCE

2” Cap Height - 24” x 18” 1 double sided panel - Front and back of panel are the same

24” x 6”

Front

Back

ID 5.0 - Park Identity Scale: 3/4” = 1” - 0” and 1/4” = 1” - 0” Painted aluminum posts and routed 30lbs HDU panel and arrowhead Install in previous location

Drawing Date Pa g e

3.0 Identity Sign Project

MIMA-2022-1392-ID

11-02-2022

Minute Man National Historical Park

George Hall House

National Park Service U.S. Department of the Interior

Minute Man National Historical Park

Gowing-Clark House

National Park Service U.S. Department of the Interior

Minute Man National Historical Park

Circa 1836

Nathan Meriam House

National Park Service U.S. Department of the Interior

Minute Man National Historical Park

Circa 1705

Burke House

National Park Service U.S. Department of the Interior

Minute Man National Historical Park

Circa 1904

ID 9.0 - Facility Identity Scale: 1” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS single sided frame with panel printed double sided - direct print aluminum panel Installed parallel to the road

2” Cap Height - 30” x 18” 1 double sided panel - Front and back of panel are the same

East Quarter School House

National Park Service U.S. Department of the Interior

Minute Man National Historical Park

ID 11.0 - Facility Identity Scale: 1” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS single sided with 2 frames with panels printed double sided - direct print aluminum panel Installed parallel to the road PRIVATE RESIDENCE

2” Cap Height - 24” x 18” 1 double sided panel - Front and back of panel are the same

24” x 6”

Front

Back

ID 12.0 - Facility Identity Scale: 1” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS single sided with 2 frames with panels printed double sided - direct print aluminum panel Installed parallel to the road PRIVATE RESIDENCE

2” Cap Height - 24” x 18” 1 double sided panel - Front and back of panel are the same

24” x 6”

Front

Back

ID 8.0 - Facility Identity Scale: 1” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS single sided with 2 frames with panels printed double sided - direct print aluminum panel Installed parallel to the road

PRIVATE RESIDENCE

2” Cap Height - 30” x 18” 1 double sided panel - Front and back of panel are the same

30” x 6”

Front

Back

ID 10.0 - Facility Identity Scale: 1” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS single sided with 2 frames with panels printed double sided - direct print aluminum panel Installed parallel to the road

PRIVATE RESIDENCE

24” x 6”

Front

Back

2” Cap Height - 24” x 18” 1 double sided panel - Front and back of panel are the same

Circa 1853

Circa 1865

Drawing Date Pa g e

4.0 Identity Sign Project

MIMA-2022-1392-ID

11-02-2022

Minute Man National Historical Park

Farwell Jones House

National Park Service U.S. Department of the Interior

Minute Man National Historical Park

Pre-1775

ID 14.0 - Facility Identity Scale: 1” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS single sided with 2 frames with panels printed double sided - direct print aluminum panel Installed parallel to the road PRIVATE RESIDENCE

2” Cap Height - 24” x 18” 1 double sided panel - Front and back of panel are the same

24” x 6”

Front

Back

Olive Stow House

National Park Service U.S. Department of the Interior

Minute Man National Historical Park

Circa 1786

ID 15.0 - Facility Identity Scale: 1” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS single sided with 2 frames with panels printed double sided - direct print aluminum panel Installed parallel to the road PRIVATE RESIDENCE

2” Cap Height - 24” x 18” 1 double sided panel - Front and back of panel are the same

24” x 6”

Front

Back

Inferrera House

National Park Service U.S. Department of the Interior

Minute Man National Historical Park

ID 16.0 - Facility Identity Scale: 1” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS single sided with 2 frames with panels printed double sided - direct print aluminum panel Installed parallel to the road PRIVATE RESIDENCE

2” Cap Height - 24” x 18” 1 double sided panel - Front and back of panel are the same

24” x 6”

Front

Back

Samuel Brooks House

National Park Service U.S. Department of the Interior

Minute Man National Historical Park

Circa 1692

ID 17.0 - Facility Identity Scale: 1” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS single sided with 2 frames with panels printed double sided - direct print aluminum panel Installed parallel to the road PRIVATE RESIDENCE

2” Cap Height - 30” x 18” 1 double sided panel - Front and back of panel are the same

30” x 6”

Front

Circa 1927

Joshua Brooks House

National Park Service U.S. Department of the Interior

Minute Man National Historical Park

PRIVATE RESIDENCE

Noah Brooks Tavern

National Park Service U.S. Department of the Interior

Minute Man National Historical Park

Circa 1798

ID 18.0 - Facility Identity Scale: 1” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS single sided with 2 frames with panels printed double sided - direct print aluminum panel Installed parallel to the road PRIVATE RESIDENCE

2” Cap Height - 24” x 18” 1 double sided panel - Front and back of panel are the same

24” x 6”

Front

Back

ID 20.0 - Facility Identity Scale: 1” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS single sided with 2 frames with panels printed double sided - direct print aluminum panel Installed parallel to the road

National Park Service | Harpers Ferry Center | Media Development | Signs

Project Number

Drawing Date Pa g e

5.0 Identity Sign Project

MIMA-2022-1392-ID

11-02-2022

Minute Man National Historical Park

2” Cap Height - 30” x 18” 1 double sided panel - Front and back of panel are the same

30” x 6”

Front

Back

Job Brooks House

National Park Service U.S. Department of the Interior

Minute Man National Historical Park

ID 19.0 - Facility Identity Scale: 1” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS single sided with 2 frames with panels printed double sided - direct print aluminum panel Installed parallel to the road

2” Cap Height - 24” x 18” 1 double sided panel - Front and back of panel are the same

NO PUBLIC ACCESS

24” x 6” 1 double sided panel - Front and back of panel are the same

Samuel Hartwell Chimney Shelter

Captain William Smith House Circa 1692

R a n g e r S t a t i o n

National Park Service U.S. Department of the Interior

Minute Man National Historical Park

National Park Service | Harpers Ferry Center | Media Development | Signs

Project Number

Drawing Date Pa g e

6.0 Identity Sign Project

MIMA-2022-1392-ID

11-02-2022

Minute Man National Historical Park

ID 25.0 - Facility Identity Scale: 1” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS double sided frame with each panel printed double sided - direct print aluminum panel Installed perpendicular to the road

NO PUBLIC ACCESS

2” Cap Height - 24” x 18” 2 double sided panels - Front and back of each panel are the same Note: Tracking on this sign has been increased to 150 pt for the main text

24” x 6” 2 double sided panels - Front and back of each panel are the same

ID 24.0 - Facility Identity Scale: 1” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS single sided with 2 frames with panels printed double sided - direct print aluminum panel Installed parallel to the road

2” Cap Height - 30” x 12” 1 double sided panel - Front and back of panel are the same

ID 26.0 - Facility Identity Scale: 1” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS single sided with 2 frames with panels printed double sided - direct print aluminum panel Installed parallel to the road

2” Cap Height - 30” x 18” 1 double sided panel - Front and back of panel are the same

John Nelson House

National Park Service U.S. Department of the Interior

Minute Man National Historical Park

ID 28.0 - Facility Identity Scale: 1” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS single sided with 2 frames with panels printed double sided - direct print aluminum panel Installed parallel to the road PRIVATE RESIDENCE

2” Cap Height - 24” x 18” 1 double sided panel - Front and back of panel are the same

24” x 6”

Front

Drawing Date Pa g e

7.0 Identity Sign Project

MIMA-2022-1392-ID

11-02-2022

Minute Man National Historical Park

Jacob Whittemore House

National Park Service U.S. Department of the Interior

Minute Man National Historical Park

Pre-1754

ID 32.0 - Facility Identity Scale: 1” = 1” - 0” and 1/4” = 1” - 0” Painted Aluminum VIS single sided with 2 frames with panels printed double sided - direct print aluminum panel Installed parallel to the road

2” Cap Height - 30” x 18” 1 double sided panel - Front and back of panel are the same

ID 33.0 - Main Park Identity Scale: 1/2” = 1” - 0” and 1/4” = 1” - 0” Field Stone monolith base and routed 30lbs HDU panel with painted aluminum arrowhead Stone illustration is not representative of final look, see fabrication details, written specifications, and photos.

Sign location to move from original See Sign Location Information 9” Cap Height - 120” x 60” with 30” tall base - Front NTS - Blank Back Panel

Minute Man National Historical Park

National Park Service U.S. Department of the Interior

File details come from the government source that posted it. Updated .