TAG
| TYPE |
| LOCATION |
| AREA SERVED |
| COND. OF EQUIP. |
| Date of MFG |
| MODEL NUMBER AND/OR NOTES |
| MFR. |
| Operates Year Round (YorN)? |
| Water Cooled Chillers |
| C017 Basement Bldg 200 |
| Bldg 200 |
| 2020 |
| 1200 Ton Centrifugal water cooled chiller |
| Carrier |
| N |
| Modular Cooling Towers |
| Above Loading Dock Connector Bldg 200 to Bldg 1 |
| Bldg 200 |
| 2020 |
| Building Automation System (BAS) Niagra Johnson Controls FX |
| Bldg 200 |
| All of Campus |
| 2020 |
| BAS supervisory control over 80% of systems on campus. |
| Johnson Controls FX |
| Y |
| AIR COOLED CHILLER |
| bldg 1 COURTYARD A |
| A432-1 RESEARCH |
| NEW |
| 2022 |
| AIR COOLED CHILLER |
| bldg 1 B SECTION EAST |
| B309-1 RESEARCH |
| POOR |
| 1980? |
| UNKNOWN |
| CARRIER |
| N |
| AIR COOLED CHILLER |
| bldg 1 COURTYARD B |
| B404-1 RESEARCH |
| NEW |
| 2022 |
| AIR COOLED CHILLER |
| bldg 1 COURTYARD C |
| C400-1 RESEARCH |
| POOR |
| 1982 |
| M: RTAA100AYR01A300KNBD S: U06C06468 |
| TRANE |
| N |
| AIR COOLED CHILLER |
| bldg 8 COURTYARD |
| C436-1 Research |
| POOR |
| 1992 |
| M: 30GB-125-650AA S: 4992F26709 Under Contract for replacement 2023 |
| CARRIER |
| N |
| SCREW CHILLER |
| bldg 1 D108 |
| D108 AHU |
| FAIR |
| 1982 |
| M: RTWA1254XH01D3C0W S: U07J05900 |
| TRANE |
| N |
| SCREW CHILLER |
| bldg 1 D108 |
| D108 AHU |
| FAIR |
| 1982 |
| M: RTWA1254XH01D3C0W S: U07J05899 |
| TRANE |
| N |
| AIR COOLED CHILLER |
| BLDG 9 courtyard |
| 9 |
| GOOD |
| 1982 |
| M: CGAM020A2L02AXB2A1A1 S:U14J45213 |
| TRANE |
| N |
| AIR COOLED CHILLER |
| BLDG 16 |
| BLDG 16 |
| GOOD |
| 2016 |
| 30RBA08066 |
| Carrier |
| N |
| AIR COOLED DX UNIT |
| 113 N. |
| Bldg. 113 |
| FAIR |
| 2004 |
| 38AH-084-601FA |
S/N 2104F35573
| AIR COOLED DX UNIT |
| 113 N. |
| Bldg. 113 |
| FAIR |
| 2004 |
| 38AH-084-601FA |
S/N 2104F35581
| AIR COOLED DX UNIT |
| 128 N. |
| Bldg. 128 |
| FAIR |
| 2004 |
| 38AH-084-601FA |
S/N 2104F35571
| AIR COOLED DX UNIT |
| 128 N. |
| Bldg. 128 |
| FAIR |
| 2004 |
| 38AH-084-601FA |
S/N 2104F35575
| AIR COOLED CHILLER |
| bldg 217 Ground Level, South Unit, CU-1 |
| 2nd Fl |
| FAIR |
| 1988 |
| RAUCC604PY03A |
ODFOOTOO
S/N C06L11140
| AIR COOLED CHILLER |
| bldg 217 Ground Level, North Unit, CU-2 |
| 2nd Fl |
| FAIR |
| 1988 |
| RAUCC604PY03A |
ODFOOTOO
S/N C06L1141
| AIR COOLED CHILLER |
| bldg 217 Ground Level, East Unit, Chiller-1 |
| 1st Fl |
| Good |
| 2013 |
| M#30RAP0806D |
A0Q3C4 S#3713Q79617
| AIR COOLED CHILLER |
| bldg 217 Ground Level, West Unit, Chiller-2 |
| 1st Fl |
| Good |
| 2013 |
| M#30RAP0806D |
A0Q3C4 S#3713Q79625
| SCREW CHILLER |
| BLDG 220 |
| BLDG 220 |
| FAIR |
| 2011 |
| M: 30HXC086M-U671KA150016530 S: 5111Q19738 |
| CARRIER |
| N |
| AIR COOLED CHILLER |
| bldg 221 2nd Fl Roof |
| 221 |
| GOOD |
| 2010 |
| 30RBB1205CB58---L |
S/N 3510Q74812
| CENTRIFUGAL CHILLER |
| Basement, Bldg 228 |
| 228 |
| GOOD |
| 2000 |
| RCU #1 PEH-063 Serial: 5TJ0100300 |
| McQuay |
| N |
| CENTRIFUGAL CHILLER |
| Basement, Bldg 228 |
| 228 |
| GOOD |
| 2000 |
| RCU #1 PEH-063 Serial: 5TJ0100200 |
| McQuay |
| N |
| AIR COOLED CHILLER |
| bldg 229, roof |
| 229 RESEARCH |
| POOR |
| 1980 |
| M: ALR050C S: 5XC0186000 |
| MCQUAY |
| N |
| AIR COOLED CHILLER |
| bldg 1, east G section |
| G210-1 |
| FAIR |
| 1988 |
| M: CGAFC50EALA100D S: C06L11139 |
| TRANE |
| N |
| CHILLER |
| Basement, Bldg 200, NW corner Stone Space |
| Linear Accelerator |
| DEAD |
| 2014 |
| MPC-A0800-RL/CHP.SS S#Y06I19846 |
| Motivair |
| Y |
| Air-Cooled Condenser |
| Bldg 200 NW, near dock |
| Linear Accelerator |
| POOR |
| 2014 |
| MPC-A0800-RL/CHP.SS S#Y06I19846 |
| Motivair |
| Y |
| CHILLER |
| Basement, Bldg 200, NW corner Stone Space |
| Linear Accelerator |
| DEAD |
| 2014 |
| MPC-A0800-RL/CHP.SS S#Y06I19845 |
| Motivair |
| Y |
| Air-Cooled Condenser |
| Bldg 200 NW, near dock |
| Linear Accelerator |
| POOR |
| 2014 |
| MPC-A0800-RL/CHP.SS S#Y06I19845 |
| Motivair |
| Y |
| AIR COOLED CHILLER |
| Bldg 200 NW, near dock |
| Linear Accelerator, AHU Zones |
| GOOD |
| 2007 |
| 30RAN035--611KA S#1107Q0696Z |
| Carrier |
| Y |
| Indoor Unit |
| MRI Room |
| MRI Machine |
| GOOD |
| 2018 |
| SCS-018SSA S#10301361 |
| Stulz |
| Y |
| Air-Cooled Condenser |
| Roof, Bldg 200 SW |
| MRI Machine |
| GOOD |
| 2018 |
| SCS-018SSA S#10301361 |
| Stulz |
| Y |
| Indoor Unit |
| MRI Room |
| MRI Server Room |
| GOOD |
| 2018 |
| SCS-018SSA S#10301362 |
| Stulz |
| Y |
| Air-Cooled Condenser |
| Roof, Bldg 200 SW |
| MRI Server Room |
| GOOD |
| 2018 |
| SCS-018SSA S#10301362 |
| Stulz |
| Y |
| "Bohn" Air Cooled Chiller & Bundle |
| East of NW PH, 2nd Fl Roof & D203C |
| Blood Lab, Cath Lab |
| GOOD |
| 2003 |
| 30GTN060 |
| Carrier |
| Y |
| AIR COOLED CHILLER |
| MRI, bldg 200 SW ground level |
| CT |
| GOOD |
| 2010 |
| ECO133L S/N 133.6002.01.1813.01217 |
| KKT Kraus Klimatechnik |
| Y |
| AIR COOLED CHILLER |
| MRI, bldg 200 SW ground level |
| MRI |
| FAIR |
| 2010 |
| KPC 208-L-U/S 8.5-Ton |
SERIAL 208.4001.04.215.1101
| AIR COOLED CHILLER |
| MRI, bldg 200 SW ground level |
| MRI |
| FAIR |
| 2010 |
| KSC 215-L-U/S |
S/N S215.4001.00.064.0508
| AIR COOLED CHILLER |
| PET trailer, bldg 200 dock |
| Mobile CT |
| FAIR |
| 2010 |
| Model RSACGC-72CRKT SERIAL 150903-11 |
| ICOR |
| Y |