This document is a Design Criteria Attachment (Attachment 6A) dated September 14, 2020, specifically detailing structural design specifications for a 180-foot, 4-leg self-supporting tower (SST) project for the State of California. The document appears to be associated with tower installations at three specific sites: Rattlesnake Peak, Alder Camp, and Big Lagoon, with engineering design performed by Western Utility Telecom, a steel product engineering firm located in Salem, Oregon.
The design criteria specify comprehensive technical requirements for tower construction, including wind load specifications (105 mph without ice, 50 mph with ice), seismic considerations per ASCE-7-16, and detailed antenna and platform loading configurations. The tower design includes multiple levels of microwave and panel antenna placements at various heights (ranging from 100' to 199'), with full work platforms at 180', 160', 140', 120', and 100'. The engineering documentation covers 16 distinct calculation and analysis areas, including overall tower design, anchor bolt calculations, antenna mount analyses, and structural component evaluations, utilizing tnxTower 8.0 software for comprehensive structural analysis.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 6A – Design Criteria September 14, 2020
St of CA – 180’ 4-Leg SST Design Criteria and Loading
The following is to be used for the base structure design of the three towers proposed for Rattlesnake Peak, Alder Camp, and Big Lagoon. Site specific design to be performed for each site considering sites specific criteria and tower loading.
Design Criteria (Governed by Rattlesnake Pk for all three Sites):
Wind, V = 105 mph (BWS) with no ice per ANSI/TIA-222 Rev. H Exposure C Risk Cat. – IV Topo Cat. – 5 (Continuous Ridge) Crest Ht. = 1,720’
Wind w/Ice, Vi = 50 mph (BWS), with ¾” design ice thickness (escalates with height) Seismic: In accordance with ASCE-7-16 and ANSI/TIA-222 Rev. H Snow Load, pg: 180 psf
Tower Loading (Based on Full Loading Table):
19’ Top Mast:
10 ¾” OD Pipe Mast w/ Beacon & 4’ Lightning Rod Mt’d @ 199’ (w/ Step Bolts)
Microwave Antennas:
170’ C.L. - (4) 10’ Ø HP Microwaves, Azimuths, 0°, 90°, 180°, 240° 150’ C.L. - (4) 10’ Ø HP Microwaves, Azimuths, 0°, 90°, 180°, 240° 130’ C.L. - (4) 10’ Ø HP Microwaves, Azimuths, 0°, 90°, 180°, 240°
Panel Antennas:
185’ C.L. – (4) Andrew DB674G65 Panel Antennas on Top Mast 181½ C.L. – (8) Andrew DB674G65 Panel Antennas on Top Platform 160’ C.L. – (16) Andrew DB674G65 Panel Antennas on Platform/Standoff Arms 140’ C.L. – (16) Andrew DB674G65 Panel Antennas on Platform/Standoff Arms 120’ C.L. – (16) Andrew DB674G65 Panel Antennas on Platform/Standoff Arms 100’ C.L. – (16) Andrew DB674G65 Panel Antennas on Platform Designer and supplier of quality engineered steel products for both the Utility &
Telecommunications Industries.
5032 Salem Dallas Hwy NW, Salem OR 97304 Phone:
503.587.0101 • fax:
503.316.1864 www.WesternUtilityTelecom.com
Full Work Platforms:
Platforms @ 180’, 160’, 140’, 120’, & 100’
Engineering Design Calculations include the following:
1) Overall Tower design performed in tnxTower 8.0 software, a commercially available analysis software suite for communication structures, which is acceptable by DSA.
2) Diagonal End Tab Calculations
3) Tower Girt End Connection Calculations
4) Risa plate element analysis for gusseted tension leg flange plate capacity verification.
5) Tower Anchor Bolt Calculations
6) 6’ Single Standoff UHF/VHF Antenna Mount Analysis
7) 6’ Double Standoff UHF/VHF Antenna Mount Analysis
8) Microwave Ice Shield Analysis
9) Microwave Antenna Pipe Mount & Bracket / Strut Force Analysis
10) Center Waveguide Cage Design
11) Climbing Ladder Design
12) Handrails, Post, & Diagonal Combined Loading Analysis
13) Microwave Coax Ice Bridge Analysis
14) U-Bolt Analysis
15) Tower Leg Tab Weld Analysis
16) Lightning Rod Spoked Mounting Flange Design
Vortex Shedding Analysis (or analyses) performed under separate line item.