Attachment 6 - Figures - Well Diagrams.pdf

PDF 61 KB Posted

Attached to
Subsurface Air Rotary Drilling
Solicitation number
6100063456
Issued by
Cambria County, Pennsylvania

About this file

The document is a technical specification for well construction and abandonment diagrams, likely part of a state or local government infrastructure project. The file contains three detailed technical figures (Figure No. 1, 2, and 3) that illustrate different well completion and abandonment techniques, including typical above-ground level completion, flush mount completion, and borehole abandonment methods. These diagrams provide standardized technical guidance for constructing and sealing boreholes, with specific details about casing types, cement grouting, surface treatments, and geological considerations.

The diagrams specify technical requirements such as minimum depths for grout seals (10 feet), surface casing specifications, and materials to be used in different stages of well construction and closure. The figures include provisions for various geological conditions, such as rock strata, overburden, and potential void or coal seam scenarios. A notable technical note indicates that in cases of significant water quantities in bedrock, a bentonite seal might be required below the aquifer. The drawings are not to scale but provide comprehensive technical guidance for contractors on proper well construction and abandonment protocols.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Overburden

4 ft

TARGET DEPTH

Grout Basket

Min 10 ft Grout Seal

Stemming (Approved Material) or

Cement Grout

FIGURE NO. 1

Rock Strata

TYPICAL ABOVE GROUND LEVEL COMPLETION

Plastic or Steel Casing

(not to scale)

Min 18 inches

Locking Cap of

Contractor Design

Ground LevelSurface Casing

Cement Grout

Overburden

4 ft

TARGET DEPTH

Grout Basket

Min 10 ft Grout Seal

Stemming (Approved Material) or

Cement Grout

TYPICAL FLUSH MOUNT COMPLETION

Plastic or Steel Casing

(not to scale)

FIGURE NO. 2

Slip Fit Casing

Cap/Cover

Cement Grout

Ground Level

Surface Casing

Rock Strata

Void or Coal Seam

Ground Level

PLUG of Contractors Choice

Min 10 Ft Cement Seal

BOREHOLE ABANDONMENT

Not to Scale

Overburden

Crushed Stone, Sand, Gravel or Drill Cuttings

Cement Plug

Topsoil or Pavement

• In the event significant quantities of water encountered in the bedrock, a Bentnite Seal might be required to be set below the Aquifer.

FIGURE NO. 3

Uncased Borehole

ROCK STRATA