11/16/18

Request for Technical Literature

a. The vendor shall provide, with its quote, descriptive literature that has previously been used to market the proposed. The literature will be used to technically evaluate the proposal and shall describe how the Floor Jacks meets requirements of the specification; specifically the paragraphs:

1. REQUIREMENTS

a. LIFTING BRACKET:

Hoisting/Lowering Speed: 9 Inches per Minute Low Position: 2’-3" High Position: 8’-3”above Jack Base Plate Total Effective Lift: 6’-0”

b. ELECTRICAL:

Master Control Receptacle(s) shall be furnished with Jacks #1 & #4 for attachment of pendant control with cable and plug. There shall be a Selector Switch on Jack #1 for pendant control from Jacks #1 or #4 and an “Emergency Stop” button at each jack control panel.

Motors: HP Electrical Service: 460V - 3PH - 60HZ

c. MOTOR AND CONTROLS:

Each Jack shall be equipped with a totally enclosed, intermittent duty, hoist type motor with an integrally mounted disc brake and a NEMA size magnetic across-the-line reversing starter. Each starter shall be complete with overload protection, a transformer for reducing the voltage in the control circuit to 120 volts and “Up- Down” push buttons mounted in the front cover; all in a NEMA type 12 enclosure.

Each set of Jacks shall include one (1) pendant master push button station in a weatherproof enclosure attached to 25 feet of control cable. Jacks shall be equipped with receptacle(s) as specified, capable of receiving the plug on the control cable. This will allow the operator to stand where he/she can see and properly control the hoist and lowering operations of the set of Jacks. Jacks may be operated individually by push button in motor starter cover. Emergency stop buttons shall be on each Jack control panel.

d. ELECTRICAL CABLES:

Electrical cables shall include 75 feet of main power cable complete with plug and a main power outlet receptacle. The interconnecting power and control cables, plugs and receptacles for the set of Jacks shall be furnished complete in the following configuration:

75 feet between Jacks #1 and #3; 35 feet between Jacks #1 and #2 as well as Jacks #3 and #4.

11/16/18

2. OPTIONAL FEATURES TO BE INCLUDED:

a. Zero Speed Shutdown System: Automatically shuts down all jacks in a set if one jack screw stops turning.

b. Upper Over travel Limit Switch: Prevents over travel of the lifting bracket in the event of failure of the operating upper limit switch.

b. The features, which must be addressed in the descriptive literature, are necessary to consider the bid responsive. If the bidder’s preprinted literature does not show all these features, the bidder must attach a letter of supplemental information to the literature describing in detail those required features.

c. The failure of descriptive literature to show that the product offered conforms to the requirements of this solicitation will require rejection of the bid.

d. Descriptive literature furnished under this solicitation that contains statements similar to ‘specifications are subject to change without notice’, proposal is subject to the following conditions’, or ‘prices are subject to change without notice’ shall not be considered for an award. The government has no assurance the products offered will conform to the specification; therefore, the proposal is not considered a firm offer and will not be considered for an award.

e. Vendors who furnish a product catalog to satisfy this requirement must indicate which item is the subject of the proposal by citing (highlighting, marking, etc.) model numbers and page numbers from the catalog along with the item’s price. Proposals that fail to clearly establish which item or items are being proposed will be considered non- responsive.