Attachment 3 - 801 Asbestos Report.pdf
PDF 3 MB Posted
- Attached to
- Combined 8 Building Demolition Service Federal contract opportunity
- Solicitation number
- FA480022Q0004
About this file
This document contains an asbestos inspection report and details of a related federal contract opportunity for combined demolition services. The asbestos inspection report documents the results of an inspection of Building 801 at Fort Eustis, Virginia, which identified various asbestos-containing materials including floor tile and mastic, drywall and joint compound, block sealer, transite panels, caulks, glazes, mortars, insulation, seals, and other materials. Bulk samples were collected and analyzed from the identified homogeneous areas.
The related federal contract opportunity is being issued by the Department of the Air Force Air Combat Command to demolish eight buildings at Fort Eustis, Virginia and perform site cleanup of a previously demolished building. The contractor will be responsible for management, transportation, equipment, labor, testing, and supervision to safely perform the demolitions and cleanup in accordance with attached documents, specifications, laws and regulations while focusing on safety and customer service.
View the file
Other files for this federal contract opportunity
Show all 50
Combined 8 Building Demolition Service has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS INSPECTION REPORT
OF
BUILDING 801
FORT EUSTIS, VIRGINIA
MCS JOB # 17-106S
Marine Chemist Service, Inc.
11850 Tug Boat Lane, Newport News, VA 23606-2527
Phone: (757) 873-0933 · Norfolk (757) 640-1122 Fax: (757) 873-1074 · Norfolk (757) 625-5696 www.MarineChemist.com
Asbestos Inspection Report of
Building 801 Fort Eustis, Virginia on
September 14, 2017
Prepared for:
Kevin Panchision Guernsey Tingle Architects
4350 New Town Avenue, Suite 101 Williamsburg, Virginia 23188
MCS Job #17-106S
By
Patrick Studley, CIH Virginia Asbestos Inspector License 3303 003193
Marine Chemist Service, Inc.
11850 Tug Boat Lane
Newport News, Virginia 23606
(757) 873-0933
October 4, 2017 Date Inspector Signature
TABLE OF CONTENTS
SECTION 1 ------------------------------------------------------- Asbestos Inspection Report
SECTION 2 ------------------------------------------------------- Sample Summary Table
SECTION 3 ------------------------------------------------------- General Legend and Notes
SECTION 4 ------------------------------------------------------- ACM Sketches
SECTION 5 ------------------------------------------------------- Survey Sample Location Sketches
SECTION 6 ------------------------------------------------------- Report of Analysis
SECTION 7 ------------------------------------------------------- Inspection Information
SECTION 8 ------------------------------------------------------- Credentials
Guernsey Tingle - Asbestos Report MCS Job #17-106S - Fort Eustis Building 801
SECTION 1
Asbestos Inspection Report
Guernsey Tingle - Asbestos Report
ASBESTOS INSPECTION OF BUILDING 801
FORT EUSTIS, VIRGINIA
INTRODUCTION
Background and Purpose
There has been a growing public awareness of the link between the inhalation of asbestos fibers and various diseases such as asbestosis, mesothelioma, lung, and other cancers. As a result, the Asbestos Hazard Emergency Response Act (AHERA 40 CFR Part 763) for schools grades K through 12 was established by EPA.
The necessary components of an AHERA inspection require the accredited inspector to visually inspect and assess the condition of all known or assumed friable asbestos containing building materials (ACBM); to visually inspect non - friable ACBM and touch it to determine friability, and to identify homogeneous areas of friable materials.
EPA’s National Emission Standards for Hazardous Air Pollutants (NESHAPS) require thorough inspections for asbestos in structures before the renovation or demolition of those structures.
Virginia law requires that if the initial building permit was issued prior to January 1, 1985, an asbestos inspection must be performed prior to the local authorities issuing a building permit.
In order to comply with NESHAPS, buildings to be renovated or demolished must be thoroughly inspected for asbestos containing building materials. Marine Chemist Service, Inc.
follows the AHERA sampling protocol for interior surveys and the Virginia standard for roof surveys.
The purpose of this survey was to provide information for this property concerning the location and type of accessible and/or visible asbestos containing materials prior to renovation.
In compliance with Virginia Regulations, Marine Chemist Service Inc. performed an asbestos survey of Building 801, located at Fort Eustis, Virginia on September 14, 2017.
Guernsey Tingle - Asbestos Report
General Information
Marine Chemist Service, Inc. was hired by Kevin Panchision of Guernsey Tingle to conduct an asbestos inspection and bulk sampling for suspect asbestos-containing building materials of Building 801, located at Fort Eustis, Virginia.
Authorization
Authorization to perform this testing was provided by Kevin Panchision, Guernsey Tingle on August 10, 2017. The area was unoccupied at the time of the inspection.
Warranty
This visual inspection and laboratory report has been prepared in accordance with AHERA and Virginia requirements and current accepted professional practices. A minimum number of bulk asbestos samples were collected to determine the presence or absence of asbestos. This inspection has been performed to provide the client with information concerning the presence of accessible and/or exposed suspect asbestos containing building materials. In compliance with the owner’s wishes, destructive testing was not performed. This inspection documents conditions at the time of the inspection only. No other warranties are implied or expressed.
Guernsey Tingle - Asbestos Report
SURVEY METHODS
Inspection Methods
The asbestos survey was performed by Virginia licensed asbestos inspectors. An initial visual walk through inspection was performed to identify suspect asbestos containing materials and homogeneous areas.
All buildings that are part of this survey did not contain crawlspaces. All buildings are slab on grade construction.
Sampling Methods
The Virginia licensed asbestos inspector sampled the identified suspect materials within the homogeneous areas following the visual inspection. Sampling was not performed on any inaccessible materials and did not involve destructive testing of building components. Sample locations were selected randomly but also taken at less visible locations to minimize visible damage.
LABORATORY METHODS
Analysis Methods
The bulk sample was first visually observed and described. The sample was mounted onto a slide, covered with dispersion staining oil and a cover slip, and observed under a polarized light microscope (PLM). The asbestos and non-asbestos materials in the sample are identified by this method.
The PLM microscopist estimates the amounts of asbestos and non-asbestos components by determining visually the relative volume of each to the total volume of the sample.
Guernsey Tingle - Asbestos Report
ASBESTOS INSPECTION
Document Review and On-Site Survey
Blueprints were provided for the inspection. In addition, a sketch was made of the area to indicate sample/asbestos material locations.
Identification of Suspect Asbestos Containing Materials
A visual inspection was performed on the suspect asbestos containing material found in the survey areas. The suspect asbestos containing materials are as follows:
1. 9” Floor Tile and Mastic under 12” Floor Tile
2. Drywall/ Joint Compound
3. Block Sealer 4. Transite Panel
5. Building Caulk 6. Door Caulk
7. Window Caulk 8. Window Glaze
9. Brick Mortar 10. Boiler Insulation
11. Tank Insulation 12. Boiler Stack Insulation
13. Pipe Sealer 14. Pipe Insulation
15. Mudded Fittings 16. Steam Line Insulation
17. Silver Paint 18. Membrane
19. Vents 20. Curb Flashing
21. Gravel Stop 22. Pitch Pocket
23. Parapet Flashing
Guernsey Tingle - Asbestos Report
Bulk Sampling
Bulk sampling was performed on all suspect asbestos-containing materials found in the areas and the minimum number of samples were taken as required in the AHERA Standards.
Bulk samples were taken penetrating all layers of the material. The samples were at least one cubic centimeter and were placed in a sealed container at the time of collection. All precautions were taken to prevent exposure to those present in or around the facility during the collection of samples. All sampling locations were patched with an encapsulant after the sampling was complete.
Samples listed below are grouped into homogeneous areas. Homogeneous areas are areas, which are uniform by color, texture, construction/application date, and general appearance.
Some sample results in the % asbestos column may be displayed in this report with a slash between two numbers, (#/#). The first number represents the first material listed in the laboratory report under the material location/description and the second number represents the second material listed.
When N/A is placed in the friable category it means the sample tested negative - (0) or less than one percent - (<1%) for asbestos and the friable description does not apply.
Samples were analyzed utilizing Polarized Light Microscopy (PLM) with dispersion staining by a NVLAP accredited laboratory (Marine Chemist Service, Inc. NVLAP Lab Code 200628-0).
The results are in section 6.
Guernsey Tingle - Asbestos Report
SECTION 2
Sample Summary Table
Sample
# Lab Sample # Material Location and Description
Asbestos
Friable
Y/N
801-1 0119812-001 Office, 9" Gray Floor Tile/ Mastic under 12" Tile 3/0 N
801-2 0119812-002 Office, 9" Gray Floor Tile/ Mastic under 12" Tile 0/0/5/5 N
801-3 0119812-003 Office, 9" Gray Floor Tile/ Mastic under 12" Tile 0/0/5/2 N
801-4 0119812-004 Office, Drywall/ Joint Compound 2/0/0 Y
801-5 0119812-005 Office, Drywall/ Joint Compound 2/0/0 Y
801-6 0119812-006 Office, Drywall/ Joint Compound 0/3/0/0 Y
801-7 0119812-007 Office, Block Sealer 0 N/A
801-8 0119812-008 Office, Block Sealer 0 N/A
801-9 0119812-009 Office, Transite Panel 40 N
801-10 0119812-010 Office, Transite Panel 40 N
801-11 0119812-011 Office, Transite Panel 40 N
801-12 0119812-012 Exterior, Building Caulk 0 N/A
801-13 0119812-013 Exterior, Building Caulk 0 N/A
801-14 0119812-014 Exterior, Door Caulk 0 N/A
801-15 0119812-015 Exterior, Door Caulk 0 N/A
801-16 0119812-016 Exterior, Window Caulk 0 N/A
801-17 0119812-017 Exterior, Window Caulk 0 N/A
801-18 0119812-018 Exterior, Window Glaze 0 N/A
801-19 0119812-019 Exterior Window Glaze 0 N/A
801-20 0119812-020 Exterior, Brick Mortar 0 N/A
801-21 0119812-021 Boiler Area, Boiler Insulation 0 N/A
801-22 void
801-23 void
801-24 0119812-022 Boiler Area, Tank Insulation 0/0/0 N/A
801-25 0119812-023 Boiler Area, Tank Insulation 0/0 N/A
801-26 0119812-024 Boiler Area, Tank Insulation 0/0 N/A
801-27 0119812-025 Boiler Area, Boiler Stack Insulation 0/0/0 N/A
801-28 0119812-026 Boiler Area, Boiler Stack Insulation 0/0/0 N/A
801-29 0119812-027 Boiler Area, Boiler Stack Insulation 0/0/0 N/A
801-30 0119812-028 Boiler Area, Pipe Sealer 0/0 N/A
801-31 0119812-029 Boiler Area, Pipe Sealer 0/0 N/A
801-32 0119812-030 Boiler Area, Pipe Sealer 0/0/0 N/A
Building 801
Fort Eustis
Guernsey Tingle - Asbestos Report
Sample
# Lab Sample # Material Location and Description
Asbestos
Friable
Y/N
801-33 0119812-031 Bathroom, Pipe Insulation 0/40 Y
801-34 0119812-032 Bathroom, Pipe Insulation 0/40 Y
801-35 0119812-033 Bathroom, Pipe Insulation 0/0 N/A
801-36 0119812-034 Bathroom, Mudded Fitting 0/30 Y
801-37 0119812-035 Bathroom, Mudded Fitting 0/40 Y
801-38 0119812-036 Boiler Area, Steamline Insulation 0/20 Y
801-39 0119812-037 Boiler Area, Steamline Insulation 0/10 Y
801-40 0119812-038 Boiler Area, Steamline Insulation 0/20 Y
801-41 0119812-039 Boiler Area, Silver Paint 0 N/A
801-42 0119812-040 Boiler Area, Silver Paint 0 N/A
801-43 0119812-041 Upper Roof, Membrane 0/0 N/A
801-44 0119812-042 Upper Roof, Membrane 0/0/0 N/A
801-45 0119812-043 Upper Roof, Membrane 2/0/0 N
801-46 0119812-044 Upper Roof, Vent 5/0 N
801-47 0119812-045 Upper Roof, Vent 5/0 N
801-48 0119812-046 Upper Roof, Curb Flashing 5 N
801-49 0119812-047 Upper Roof, Curb Flashing 2/5/0 N
801-50 0119812-048 Upper Roof, Gravel Stop 0/0/0 N/A
801-51 0119812-049 Upper Roof, Gravel Stop 0/0 N/A
801-52 0119812-050 Upper Roof, Pitch Pocket 2/5 N
801-53 0119812-051 Bathroom Roof, Membrane 0/0/0 N/A
801-54 0119812-052 Bathroom Roof, Membrane 2/0/0 N
801-55 0119812-053 Bathroom Roof, Membrane 0/0/0 N/A
801-56 0119812-054 Bathroom Roof, Vent 5/0/0 N
801-57 0119812-055 Bathroom Roof, Gravel Stop 0 N
801-58 0119812-056 Bathroom, Roof, Gravel Stop 2/0/0 N
801-59 0119812-057 Bathroom Roof, Parapet Flashing 5 N
801-60 0119812-058 Bathroom Roof, Pitch Pocket 5 N
Guernsey Tingle - Asbestos Report
Comments
1. The following sampled materials tested positive for asbestos:
a. 9” Gray Floor Tile and Mastic under 12” Floor Tile
b. Joint Compound on Drywall
c. Transite Panel
d. Pipe Insulation
e. Mudded Fittings
f. Steam Line Insulation
g. Upper Roof Membrane
h. Upper Roof Vents
i. Upper Roof Curb Flashing
j. Upper Roof Pitch Pockets
k. Bathroom Roof Membrane
l. Bathroom Roof Vents
m. Bathroom Roof Pitch Pockets
n. Bathroom Roof Gravel Stop
o. Bathroom Roof Parapet Flashing
2. Standard practice for asbestos/nonasbestos material classification is if one sample of a material tests positive, all of the corresponding material throughout the building is assumed to be of the same composition.
3. The 9” Floor Tile and Mastic under 12” Floor Tile in the Office Area is considered a
Category I Nonfriable material (unless rendered friable) and may be removed in a Class II work area by properly trained and qualified personnel.
4. Because the total content of asbestos in the Drywall/Joint Compound Wallboard
System is less than 1%, this material does not have to be disposed of as asbestos waste. The Wallboard System must be removed by properly trained personnel using wet methods and prompt cleanup. It is recommended that this material be removed under negative pressure (with respect to the surrounding area) within a regulated area.
5. The Transite Panels between the Office Area and the Boiler Plant must be removed prior to demolition. This is considered a Category II Nonfriable material (unless rendered friable) and may be removed in a Class II work area by properly trained and qualified personnel.
7. The Pipe Insulation and Mudded Fittings in the Bathroom must be removed prior to demolition. This is considered a Friable, Regulated Asbestos Containing Material and must be removed in a Class I work area by properly trained and qualified personnel.
Guernsey Tingle - Asbestos Report
8. The Steam Line Insulation in the Boiler Plant must be removed prior to demolition.
This is considered a Friable, Regulated Asbestos Containing Material and must be removed in a Class I work area by properly trained and qualified personnel.
9. The Roof Membrane, Vents, Curb Flashings, Pitch Pockets, Gravel Stops, and Parapet
Flashings are all considered a Category I Nonfriable material (unless rendered friable) and may be removed in a Class II work area by properly trained and qualified personnel.
10. Asbestos might be found within walls, ceiling and or pipe chases during the renovation or demolition of the building. If any suspect materials are found they should treated as asbestos or tested for asbestos.
Approximate Quantities of Asbestos Materials
ASBESTOS CONTAINING MATERIALS QUANTITY CURRENT
CONDITION
9” Gray Floor Tile and Mastic under 12” Floor Tile 550 sq. ft. Fair Joint Compound on Drywall 1,500 sq. ft. Poor Transite Panel 1,000 sq. ft. Intact Pipe Insulation 25 linear ft. Intact Mudded Fittings 3 Intact Steam Line Insulation 20 linear ft. Intact Upper Roof Membrane 1,500 sq. ft. Intact Upper Roof Vents 8 Intact Upper Roof Curb Flashing 70 linear ft. Intact Upper Roof Pitch Pockets 1 Intact Bathroom Roof Membrane 180 sq. ft. Intact Bathroom Roof Vents 1 Intact Bathroom Roof Pitch Pockets 1 Intact Bathroom Roof Gravel Stop 40 linear ft. Intact Bathroom Roof Parapet Flashing 15 linear ft. Intact
SECTION 3
General Legend and Notes
Guernsey Tingle - Asbestos Report
GENERAL LEGEND
O - Sample number/location - non-asbestos
- Sample number/location - contains asbestos
- Door/Doorway
- Window
GENERAL NOTES
1. The EPA definition of a friable material is one that contains more than 1% asbestos by weight and can be crumbled, pulverized or reduced to a powder by hand pressure when dry, or which under normal use or maintenance emits or can be expected to emit asbestos fibers into the air.
2. All quantities are approximate.
3. Sketches are not to scale.
SECTION 4
Asbestos Containing Material Sketches
Asbestos Material Locations Building 801
Fort Eustis, Virginia
Transite Panels
Steam Line Insulation
Pipe Insulation
Mudded Fittings
Floor Tile/Mastic Joint Compound on Drywall
Guernsey Tingle - Asbestos Report MCS Job #17-106S - Fort Eustis Building 801
Shannon Rectangle
Shannon Rectangle
Shannon Polygonal Line
Shannon Line
Shannon Line
Shannon Rectangle
Shannon Rectangle
Shannon Rectangle
Shannon Rectangle
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Polygonal Line
Shannon Polygonal Line
Shannon Polygonal Line
Shannon Polygonal Line
Shannon Polygonal Line
Shannon Polygonal Line
Patrick Line
Patrick Line
Patrick Line
Patrick Line
Patrick Line
Asbestos Material Locations Building 801 Roof
Fort Eustis, Virginia
Roof Membrane
Pitch Pockets
Roof Vents (Typical)
Curb Flashing
Gravel Stop (Typical)
Parapet Flashing
Guernsey Tingle - Asbestos Report MCS Job #17-106S - Fort Eustis Building 801
Shannon Rectangle
Shannon Rectangle
Shannon Polygonal Line
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Polygonal Line
Shannon Polygonal Line
Shannon Polygonal Line
Shannon Polygonal Line
IH Field Rectangle
IH Field Rectangle
IH Field Rectangle
IH Field Rectangle
IH Field Rectangle
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Rectangle
IH Field Oval
Patrick Line
Patrick Line
Patrick Line
Patrick Line
Patrick Line
Patrick Line
Patrick Line
Patrick Line
Patrick Line
Patrick Line
Patrick Line
SECTION 5
Survey Sample Location Sketches
Guernsey Tingle - Asbestos Report
Asbestos Sample Locations Building 801
Fort Eustis, Virginia
9 11 816
5 4
Guernsey Tingle - Asbestos Report MCS Job #17-106S - Fort Eustis Building 801
Shannon Rectangle
Shannon Rectangle
Shannon Polygonal Line
Shannon Line
Shannon Line
Shannon Rectangle
Shannon Rectangle
Shannon Rectangle
Shannon Rectangle
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Polygonal Line
Shannon Polygonal Line
Shannon Polygonal Line
Shannon Polygonal Line
Shannon Polygonal Line
Shannon Polygonal Line
IH Field Polygon
IH Field Polygon
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Polygon
IH Field Polygon
IH Field Polygon
IH Field Polygon
IH Field Polygon
IH Field Polygon
IH Field Polygon
IH Field Polygon
IH Field Polygon
IH Field Polygon
IH Field Polygon
IH Field Polygon
IH Field Polygon
IH Field Polygon
Patrick Oval
Asbestos Sample Locations Building 801, Roof Fort Eustis, Virginia
Guernsey Tingle - Asbestos Report MCS Job #17-106S - Fort Eustis Building 801
Shannon Rectangle
Shannon Rectangle
Shannon Polygonal Line
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Oval
Shannon Polygonal Line
Shannon Polygonal Line
Shannon Polygonal Line
Shannon Polygonal Line
IH Field Rectangle
IH Field Rectangle
IH Field Rectangle
IH Field Rectangle
IH Field Rectangle
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Rectangle
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Line
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Oval
IH Field Polygon
IH Field Polygon
IH Field Polygon
IH Field Polygon
IH Field Polygon
IH Field Polygon
IH Field Polygon
IH Field Polygon
IH Field Polygon
IH Field Polygon
IH Field Polygon
Shannon Line
IH Field Polygon
SECTION 6
Reports of Analysis
Guernsey Tingle - Asbestos Report
SECTION 7
Inspection Information
Guernsey Tingle - Asbestos Report
Inspection Information
The survey contractor for the inspection of Building 801, Fort Eustis, Virginia is:
Marine Chemist Service, Inc.
11850 Tug Boat Lane Newport News, Virginia 23606 www.MarineChemist.com
The team leader responsible for quality control coordination of inspection and adherence to inspection protocol is:
Colleen Becker - CIH
11850 Tug Boat Lane
CBecker@MarineChemist.com
The AIHA and NVLAP Accredited laboratory selected to analyze the bulk samples for asbestos content by PLM, using the "Interim Method for the Determination of Asbestos in Bulk Insulation Samples” (Appendix A to Subpart F in 40 CFR Part 763) is:
Virginia Asbestos Analytical Laboratory License 3333 000004
11850 Tug Boat Lane
(757) 873-0933
The inspector who physically inspected the building and who has received EPA-Approved Training is:
Patrick Studley, CIH
Virginia Asbestos Inspector License 3303 003193 PStudley@MarineChemist.com
The Industrial Hygiene Inspector is employed by:
11850 Tug Boat Lane Newport News, Virginia 23606
(757) 873-0933
Guernsey Tingle - Asbestos Report
SECTION 8
Credentials
Guernsey Tingle - Asbestos Report
This Page May Be Removed Prior to Bid Submittal
BUILDING 801
ASBESTOS CONTAINING MATERIALS QUANTITY COST
PER UNIT
REMOVAL
COST
9” Gray Floor Tile and Mastic under 12” Floor Tile 550 sq. ft. $ 4.75 $ 2,612.50 Joint Compound on Drywall 1,500 sq. ft. $ 8.00 $ 12,000.00 Transite Panel 1,000 sq. ft. $ 5.00 $ 5,000.00 Pipe Insulation 25 linear ft. $ 10.00 $ 250.00 Mudded Fittings 3 $ 45.00 $ 135.00 Steam Line Insulation 20 linear ft. $ 25.00 $ 500.00 Upper Roof Membrane 1,500 sq. ft. $ 4.75 $ 7,125.00 Upper Roof Vents 8 $ 65.00 $ 520.00 Upper Roof Curb Flashing 70 linear ft. $ 10.00 $ 700.00 Upper Roof Pitch Pockets 1 $ 65.00 $ 65.00 Bathroom Roof Membrane 180 sq. ft. $ 4.75 $ 855.00 Bathroom Roof Vents 1 $ 65.00 $ 65.00 Bathroom Roof Pitch Pockets 1 $ 65.00 $ 65.00 Bathroom Roof Gravel Stop 40 linear ft. $ 10.00 $ 400.00 Bathroom Roof Parapet Flashing 15 linear ft. $ 10.00 $ 150.00
Total $ 30,442.50
*The abatement contractor may require a mobilization fee of approximately $ 1,600.00 in addition to removal costs. Prices may vary depending on volume of abatement that needs to be accomplished, difficulty of set up requirement, work hours, work days, accessibility of materials.
| PM Sketch.pdf |
| Blank Page |
| Blank Page |
| Blank Page |
| Blank Page |
| Blank Page |
| Blank Page |
| PM Sketch Roof.pdf |
| Blank Page |
| Blank Page |
| Blank Page |
| Blank Page |
| Blank Page |
| Blank Page |
| PM Sketch Roof.pdf |
| Blank Page |
| Blank Page |
| Blank Page |
| Blank Page |
| Blank Page |
| Blank Page |
| Sampling Locations.pdf |
| Blank Page |
| Blank Page |
| Blank Page |
| Blank Page |
| Blank Page |
| Blank Page |
File details come from the government source that posted it. Updated .