This document provides details for a federal contract solicitation to construct additions to the Fourth Floor of the Audie L. Murphy VA Hospital Cancer Center in San Antonio, Texas. The solicitation number is 36C77622B0021 and is seeking construction of a Chemotherapy Treatment Unit, Chemotherapy Pharmacy, Apheresis, Medical-Surgery Clinic and Administration offices. The federal agency issuing this solicitation is the Department of Veterans Affairs Headquarters. Responses to this solicitation are due by March 30, 2022 and the contract is expected to be awarded by June 15, 2022. The selected contractor will be responsible for all aspects of construction services to complete this 4G Cancer Center Project expansion.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project

Building

Drawing

Project Title

Location

Issue DateCheckedDrawn

Drawing

Approve

VA FORM 08 -

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

2 14567891

Phase

PROJECT MANAGEMENTSTAMP CONSULTANT

3 2 14567891

FULLY

SPRINKLERED

4G

INTERIORS

Austin, Texas 78746

ARCHITECTURE

5121 Bee Caves Road, Suite 203

T:512 -327 -4149

COX DESIGN ASSOCIATES

PLANNING

F:512 -327 -7679

Austin bcox@coxdesignassociates.com09/10/2020

BIM

360://ALM

VAH

4G

C

AN

C

ER

C

EN

TER

/ALM

VAH

_4G

C

AN

C

ER

C

EN

TER

_C

D

_AR

C H

_08182020.rvt

9/10/2020 4:34:42 PM

GI-000

CONSTRUCTION

DOCUMENTS -100%

COVER SHEETCONSTRUCT 4G CANCER

CENTER

7400 MERTON MINTER BLVD.

SAN ANTONIO, TX. 78229

09/10/2020RHCMAG

671-250

AUDIE L. MURPHY VA HOSPITAL

7400 MERTON MINTER BLVD. SAN ANTONIO, TX. 78229

CONSTRUCT 4G CANCER CENTER

PROJECT # 671-250

INTERIORS

Austin, Texas 78746

ARCHITECTURE

5121 Bee Caves Road, Suite 203

T:512 -327 -4149

COX DESIGN ASSOCIATES

PLANNING

F:512 -327 -7679 bcox@coxdesignassociates.com

ARCHITECTUREMEPELEVATOR PROJECT MANAGEMENTSTRUCTURAL

7700 Torino St, Suite 101 San Antonio, TX 78229

Telephone: 210.614.1110 © 2018 Alderson & Associates, Inc.

F-1008 Tel. (210) 340-7973

CONSULTING ENGINEERS

1950 LA MANDA BLVD.

SAN ANTONIO, TEXAS 78201

R-S-C-R, INC.

Fax. (210) 366-2324 TBPE Registration No. F-2181

DATA & COMMUNICATIONS

CONSTRUCTION DOCUMENTS -100%

Revisions:Date:

Project

Building

Drawing

Project Title

Location

Issue DateCheckedDrawn

Drawing

Approve

VA FORM 08 -

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

2 14567891

Phase

PROJECT MANAGEMENTSTAMP CONSULTANT

3 2 14567891

FULLY

SPRINKLERED

4G

INTERIORS

Austin, Texas 78746

ARCHITECTURE

5121 Bee Caves Road, Suite 203

T:512 -327 -4149

COX DESIGN ASSOCIATES

PLANNING

F:512 -327 -7679

Austin bcox@coxdesignassociates.com09/10/2020

BIM

360://ALM

VAH

4G

C

AN

C

ER

C

EN

TER

/ALM

VAH

_4G

C

AN

C

ER

C

EN

TER

_C

D

_AR

C H

_08182020.rvt

9/10/2020 4:34:43 PM

GI-001

CONSTRUCTION

DOCUMENTS -100%

INDEX OF DRAWINGSCONSTRUCT 4G CANCER

CENTER

7400 MERTON MINTER BLVD.

SAN ANTONIO, TX. 78229

09/10/2020RHCMAG

671-250

TELECOMMUNICATIONS

T-000TECHNOLOGY SYMBOLS & LEGEND AND ABBREVIATIONS

TD-104TECHNOLOGY FOURTH FLOOR MAIN BUILDING - DEMOLITION FLOOR PLAN

T-100TECHNOLOGY FOURTH FLOOR OVERALL FLOOR PLAN

T-101TECHNOLOGY EXISTING THIRD FLOOR PLAN

T-103TECHNOLOGY FOURTH FLOOR - FLOOR PLAN

T-103.1TECHNOLOGY FOURTH FLOOR MAIN BUILDING - FLOOR PLAN

T-104TECHNOLOGY FOURTH FLOOR - INTERSTITIAL PLAN

T-105TECHNOLOGY ADD ALTERNATE ENLARGED PLAN

T-300TECHNOLOGY ENLARGED ROOM LAYOUTS AND RACK ELEVATIONS

T-400TECHNOLOGY TYPICAL DETAILS

T-401TECHNOLOGY GROUNDING DIAGRAMS

T-402TECHNOLOGY TYPICAL LABELING SCHEME

TS-000SECURITY SYMBOLS, LEGEND AND ABBREVIATIONS

TS-103SECURITY 4TH FLOOR - FLOOR PLAN

TS-105SECURITY ADD ALTERNATE ENLARGED PLANS

TS-400SECURITY TYPICAL DETAILS

TS-401SECURITY TYPICAL DETAILS

TS-500SECURITY SCHEDULES

ARCHITECTURAL

AI-100FOURTH FLOOR - LIFE SAFETY PLAN

AD-101DEMOLITION - THIRD FLOOR INTERSTITIAL PLAN

AD-103DEMOLITION - THIRD FLOOR ROOF PLAN

AD-104DEMOLITION - FOURTH FLOOR PLANS

AD-201DEMOLITION - EXTERIOR ELEVATIONS

AS-100FOURTH FLOOR - OVERALL FLOOR PLAN

AS-102EXISTING THIRD FLOOR INTERSTITIAL PLAN

AS-103FOURTH FLOOR - FLOOR PLAN

AS-103.1FOURTH FLOOR MAIN BUILDING - FLOOR PLAN

AS-104FOURTH FLOOR - INTERSTITIAL PLAN

AS-105FOURTH FLOOR - ROOF PLAN

AS-110FOURTH FLOOR - DIMENSION PLAN

AS-120FOURTH FLOOR - FLOOR FINISH PLAN

AS-130FOURTH FLOOR - REFLECTED CEILING PLAN

AS-130.1ENLARGED REFLECTED CEILING PLAN

AS-201EXTERIOR ELEVATIONS

AS-202EXTERIOR ELEVATIONS

AS-203EXTERIOR ELEVATIONS

AS-204EXTERIOR ELEVATIONS

AS-301BUILDING SECTIONS

AS-302BUILDING SECTIONS

AS-303BUILDING SECTIONS

AS-304BUILDING SECTIONS

AS-305BUILDING SECTIONS

AS-306BUILDING SECTIONS

AS-310WALL SECTIONS

AS-311WALL SECTIONS

AS-312WALL SECTIONS

AS-401ENLARGED PLANS

AS-402ENLARGED PLANS

AS-403ENLARGED PLANS

AS-405ADD ALTERNATE ENLARGED PLANS

AS-410INTERIOR ELEVATIONS

AS-411INTERIOR ELEVATIONS

AS-412INTERIOR ELEVATIONS

AS-413INTERIOR ELEVATIONS

AS-414INTERIOR ELEVATIONS

AS-415INTERIOR ELEVATIONS

AS-416INTERIOR ELEVATIONS

AS-417INTERIOR ELEVATIONS

AS-418INTERIOR ELEVATIONS

AS-419INTERIOR ELEVATIONS

AS-420STAIR PLANS

AS-421STAIR SECTIONS

AS-422STAIR SECTIONS

AS-423STAIR DETAILS

AS-424ELEVATOR PLANS

AS-425ELEVATOR SECTIONS

AS-426ELEVATOR DETAILS

AS-501SECTION DETAILS

AS-502SECTION DETAILS

AS-503ROOF DETAILS

AS-504WALL PARTITION TYPES

AS-505WALL PARTITION TYPES

AS-506WALL DETAILS

AS-507CEILING DETAILS

AS-508CASEWORK DETAILS

AS-509CASEWORK DETAILS

AS-510FLOOR FINISH DETAILS

AS-511COLUMN DETAILS

AS-512COLUMN DETAILS

AS-513COLUMN DETAILS

AS-610DOOR SCHEDULE

AS-611DOOR DETAILS

AS-612DOOR DETAILS

AS-620WINDOW SCHEDULE

AS-621WINDOW DETAILS

AS-622WINDOW DETAILS

AS-630ROOM FINISH / MATERIAL FINISH SCHEDULES

ELECTRICAL

ES-001ELECTRICAL SYMBOLS AND ABBREVIATIONS

ESD-101THIRD FLOOR INTERSTITIAL PLAN - ELECTRICAL DEMOLITION

ESD-102THIRD FLOOR ROOFPLAN - ELECTRICAL DEMOLITION

ES-101FOURTH FLOOR PLAN - LIGHTING

ES-102FOURTH FLOOR INTERSTITIAL PLAN - LIGHTING

ES-201FOURTH FLOOR PLAN - POWER

ES-202FOURTH FLOOR INTERSTITIAL PLAN - POWER

ES-203FOURTH FLOOR ROOF PLAN - POWER

ES-204ENLARGED FLOOR PLAN - POWER

ES-205ENLARGED FLOOR PLANS - POWER

ES-206ENLARGED EXAM CONSULT & PROCEDURE ROOM PLANS - POWER

ES-207ENLARGED FOURTH FLOOR MAIN BUILDING FLOOR PLANS - LIGHTING AND POWER

ES-208ENLARGED FOURTH FLOOR PLANS - ADD ALTERNATE - LIGHTING AND POWER

ES-209ENLARGED FOURTH FLOOR INTERSTITIAL PLANS - ADD ALTERNATE - LIGHTING AND POWER

ES-301FOURTH FLOOR PLAN- SPECIAL SYSTEMS

ES-302FOURTH FLOOR INTERSTITIAL PLAN - SPECIAL SYSTEMS

ES-401ELECTRICAL - ONE LINE DIAGRAM - SH 1 OF2

ES-402ELECTRICAL - ONE LINE DIAGRAM - SH 2 OF2

ES-501ELECTRICAL DETAILS

ES-502ELECTRICAL DETAILS

ES-503ELECTRICAL DETAILS

ES-504ELECTRICAL DETAILS

ES-505ELECTRICAL DETAILS

ES-601ELECTRICAL SCHEDULES

ES-602ELECTRICAL SCHEDULES

ES-603ELECTRICAL SCHEDULES

MECHANICAL

MH-001MECHANICAL SYMBOLS AND ABBREVIATIONS

MHD-101THIRD FLOOR INTERSTITIAL PLAN - HVAC DEMOLITION

MHD-102THIRD FLOOR ROOF PLAN - HVAC DEMOLITION

MH-101THIRD FLOOR INTERSTITIAL PLAN - HVAC

MH-102FOURTH FLOOR PLAN - HVAC

MH-103FOURTH FLOOR INTERSTITIAL PLAN - HVAC

MH-104PARTIAL FOURTH FLOOR MAIN BUILDING PLANS - HVAC

MH-105PARTIAL FLOOR PLANS - ADD ALTERNATE - HVAC

MH-201FOURTH FLOOR ROOFPLAN - HVAC

MH-301HVAC SECTIONS

MH-401MECHANICAL SCHEDULES

MH-402MECHANICAL SCHEDULES

MH-501MECHANICAL CONTROL DIAGRAMS

MH-502MECHANICAL CONTROL DIAGRAMS

MH-601MECHANICAL DETAILS

MH-602MECHANICAL DETAILS

MP-101FOURTH FLOOR INTERSTITIAL PLAN - MECHANICAL PIPING

PLUMBING

PL-001PLUMBING SYMBOLS ANS ABBREVIATIONS

PLD-101THIRD FLOOR INTERSTITIAL PLAN - PLUMBING DEMOLITION

PLD-102THIRD FLOOR ROOF PLAN - PLUMBING DEMOLITION

PG-101FOURTH FLOOR PLAN - MEDICAL GAS

PG-102FOURTH FLOOR PLAN INTERSTIAL PLAN - MEDICAL GAS

PG-103MEDICAL GAS RISERS

PL-201THIRD FLOOR INTERSTITIAL PLAN - WASTE, WATER AND MEDICAL GAS

PL-202FOURTH FLOOR PLAN - WASTE & WATER

PL-203FOURTH FLOOR INTERSTITIAL PLAN - WASTE & WATER

PL-204FOURTH FLOOR ROOF PLAN - PLUMBING

PL-205FOURTH FLOOR PLANS - ADD ALTERNATE - PLUMBING

PL-301PLUMBING SCHEDULES

PL-401PLUMBING DETAILS

PL-501DOMESTIC WATER RISER

PL-502WASTE & VENT RISERS

FIRE PROTECTION

FP-101FOURTH FLOOR PLAN - FIRE PROTECTION

FP-102FOURTH FLOOR PLAN - ADD ALTERNATE - FIRE PROTECTION

FP-103FOURTH FLOOR PLAN - FIRE PROTECTION

STRUCTURAL

S-1.1GENERAL NOTES

S-1.2TYPICAL DETAILS

S-2.1EXISTING ROOF / NEW 4TH FLOOR FRAMING PLAN

S-2.2FOURTH FLOOR INTERSTITIAL FRAMING PLAN

S-2.3ROOF FRAMING PLAN

S-2.44TH FLOOR INTERSTITIAL AND ROOF FRAMING ADD ALTERNATE #1

S-3.1SECTIONS AND DETAILS

S-3.2SECTIONS AND DETAILS

S-3.3SECTIONS AND DETAILS

S-3.4SECTIONS AND DETAILS

GENERAL

GI-000COVER SHEET

GI-001INDEX OF DRAWINGS

GI-002VICINITY MAP AND GENERAL NOTES

GI-003ARCHITECTURAL ABBREVIATIONS

GI-004ACCESSIBILITY STANDARDS

GI-005ACCESSIBILITY STANDARDS

GI-006ACCESSIBILITY STANDARDS

GI-007ACCESSIBILITY STANDARDS

GI-008ACCESSIBILITY STANDARDS

GI-009SITE PLAN - OVERALL CAMPUS SITE PLAN

GI-010SITE PLAN - LIMITS OF CONSTRUCTION

INDEX OF DRAWINGS:

TECHNOLOGY

MAIN BUILDING

4G CANCER CENTER

AUDIE L. MURPHY

MEMORIAL VA HOSPITAL

UNLESS NOTED AS EXISTING, ALL MATERIALS, EQUIPMENT, MANUFACTURED

ITEMS AND ASSEMBLIES INCORPORATED INTO THE WORK SHALL BE NEW.

1.

UNLESS NOTED TO BE REMOVED AND DISPOSED, ALL EXISTING ITEMS ARE TO

REMAIN. THEY SHALL BE PROTECTED FROM DAMAGE DUE TO CONSTRUCTION

ACTIVITIES. ANY EXISTING ITEMS TO REMAIN THAT BECOME DAMAGED DUE TO

CONSTRUCTION ACTIVITIES SHALL BE REPAIRED OR REPLACED TO MATCH

EXISTING AT NO ADDITIONAL COST TO THE OWNER..

NOTATIONS FOR ITEMS OF WORK APPLY TO EACH AND EVERY GRAPHICAL

INDICATION SHOWN ON THE DRAWINGS, WHETHER OR NOT NOTED.

ALL ITEMS NOTED TO HAVE PAINT FINISH SHALL BE THOROUGHLY CLEANED AND

PROPERLY PREPARED IN ACCORDANCE WITH THE SPECIFICATIONS PRIOR TO

THE APPLICATION OF PRIMER AND PAINT.

THE CONTRACTOR SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE

MECHANICAL, ELECTRICAL, AND PLUMBING WORK AND SATISFY THE

REQUIREMENTS FOR SUPPORT, FLOOR, WALL AND ROOF OPENINGS, FLASHINGS

AND CURBS ETC. THE ARCHITECT SHALL BE NOTIFIED OF CONFLICTS OR

DISCREPANCIES PRIOR TO COMMENCEMENT OF CONSTRUCTION.

2.

3.

4.

5.

CONTRACTOR TO REPLACE & ACCURATELY LOCATE ALL EXISTING SIGNAGE

AND LABELS NOTING RATED WALL ASSEMBLIES AND SMOKE PARTITIONS

THE GENERAL CONTRACTOR SHALL VISIT THE SITE, VERIFY FIELD CONDITIONS

AND CAREFULLY COMPARE SUCH FIELD CONDITIONS AND OTHER INFORMATION

KNOWN TO THE CONTRACTOR WITH CONTRACT DOCUMENTS.

THE GENERAL CONTRACTOR SHALL REPORT ANY UNFORESEEN FIELD

CONDITIONS, ERRORS, INCONSISTENCIES, OR OMISSIONS DISCOVERED AT ANY

TIME DURING THE WORK, UPON SUCH DISCOVERY, THE CONTRACTOR SHALL

IMMEDIATELY CONTACT THE CONTRACT OFFICER FOR CLARIFICATION BEFORE

PROCEEDING OR CONTINUING WITH THAT PORTION OF THE WORK OR ANY

PORTION RELATED THERE TO.

ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND STANDARDS

INCLUDING THE INTERNATIONAL BUILDING CODE 2015 EDITION, VA MASTER

SPECIFICATIONS, AND NFPA 101 2015 EDITION.

THE GENERAL CONTRACTOR SHALL NOTIFY THE CONTRACT OFFICER,

CONTRACTING OFFICER'S REPRESENTATIVE, AND ARCHITECT OF ANY

DISCREPANCIES BETWEEN THE DRAWINGS, NOTES AND ACTUAL FIELD

CONDITIONS BEFORE BIDDING AND COMMENCING ANY WORK, AND REQUEST

CLARIFICATION IN WRITING.

WHEN UNANTICIPATED MECHANICAL, ELECTRICAL, OR STRUCTURAL ELEMENTS

THAT CONFLICT WITH THE INTENDED FUNCTION OR DESIGN ARE

ENCOUNTERED, INVESTIGATE AND MEASURE THE NATURE AND EXTENT OF THE

CONFLICT. PROMPTLY SUBMIT A WRITTEN REPORT TO THE CONTRACT

OFFICER.

WHERE MOUNTING HEIGHTS ARE NOT INDICATED, INSTALL COMPONENTS USING

MANUFACTURER'S OR INDUSTRY STANDARDS. WHERE STANDARDS DO NOT

EXIST, NOTIFY THE ARCHITECT FOR CLARIFICATION.

CONTRACTOR SHALL NOT BARRICADE / BARRIER EMERGENCY EGRESS TO OR

FROM THIS AREA. CONTRACTOR SHALL MAINTAIN EXIT TO EXTERIOR DURING

THE WORK PROCESS

PROVIDE ACCESS TO THE WORK AS DIRECTED BY THE C.O.R. SECURE ACCESS

POINT AS SPECIFIED AND DIRECTED BY THE COR PROJECT ENGINEER. PROVIDE

WALK-OFF MATS TO MEET FACILITY INFECTION CONTROL GUIDELINES AT EACH

ACCESS POINT.

CONTRACTOR TO NOTIFY VA 2 WEEKS IN ADVANCE PRIOR TO ANY

MAJOR UTILITY DISRUPTIONS OR OUTAGES. MAJOR OUTAGES

INVOLVING EMERGENCY AND CRITICAL BRANCH, SHALL BE

COORDINATED NOT LESS THAN 21CALENDAR DAYS.

IN THE CASE OF CONFLICTS OR DISCREPANCIES WITHIN OR AMONG

THE CONTRACT DOCUMENTS, THE BETTER QUALITY, MORE STRINGENT

REQUIREMENTS OR GREATER QUANTITY OF WORK, AS DETERMINED BY

THE GOVERNMENT, SHALL BE PROVIDED.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

Project

Building

Drawing

Project Title

Location

Issue DateCheckedDrawn

Drawing

Approve

VA FORM 08 -

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

2 14567891

Phase

PROJECT MANAGEMENTSTAMP CONSULTANT

3 2 14567891

FULLY

SPRINKLERED

4G

INTERIORS

Austin, Texas 78746

ARCHITECTURE

5121 Bee Caves Road, Suite 203

T:512 -327 -4149

COX DESIGN ASSOCIATES

PLANNING

F:512 -327 -7679

Austin bcox@coxdesignassociates.com09/10/2020

BIM

360://ALM

VAH

4G

C

AN

C

ER

C

EN

TER

/ALM

VAH

_4G

C

AN

C

ER

C

EN

TER

_C

D

_AR

C H

_08182020.rvt

9/10/2020 4:34:45 PM

GI-002

CONSTRUCTION

DOCUMENTS -100%

VICINITY MAP AND GENERAL

NOTES

CONSTRUCT 4G CANCER

CENTER

7400 MERTON MINTER BLVD.

SAN ANTONIO, TX. 78229

09/10/2020RHCMAG

671-250

DRAWINGS FOR THE FOLLOWING DISCIPLINES ARE

CONTAINED IN THE DOCUMENT. THE DISCIPLINES ARE

IDENTIFIED BY THE REFERENCE WHICH IS

INCORPORATED INTO THE SHEET TITLE.

EACH DRAWING IS NUMBERED ACCORDING TO IT'S

LOCATION ON THE SHEET. THE DRAWING TITLE

APPEARS ABOVE THE DEMARCATION LINE AND, APPROPRIATE THE

SCALE IS LOCATED BELOW THE DEMARCATION LINE IN THE LOWER

LEFT-HAND QUADRANT OF THE KEY. THE DRAWING CAN BE

REFERENCED BACK TO IT'S ORIGINAL SHEET AND

DRAWING BY THE DRAWING REFERENCE LOCATION IN

THE LOWER RIGHT-HAND QUADRANT.

SHEET NUMBER

DRAWING NUMBER ON SHEET BY LOCATION

REFERENCE

EXCEPT WHERE DIRECTED TO PLACE ITEMS OF THE WORK AT THE

"APPROXIMATE LOCATION SHOWN." DO NOT SCALE DRAWINGS FOR

DIMENSIONAL INFORMATION

1.

ALL ELEMENTS OF THE DOCUMENTS MAY NOT BE DRAWN TO EXACT SCALE.

ALL DIMENSIONS REQUESTED ARE SHOWN (OR MAY BE DERIVED FROM THOSE

SHOWN OR NOTED) ON THE FLOOR PLANS. DETAIL PLANS, ELEVATIONS,

SECTIONS, SCHEDULES, CONFIGURATION DETAILS, AND SPECIFICATIONS. SEE

THE NOTES BELOW AND SYMBOLS FOR DIMENSIONING CONVENTIONS USED

ON THIS PROJECT.

2.

EXCEPT WHERE SPECIFICALLY NOTED TO THE CONTRARY, ALL DIMENSIONS

SHOWN ON THE ARCHITECTURAL DRAWINGS CONFORM TO THE FOLLOWING

CONVENTIONS.

3.

DIMENSIONS UTILIZING THE "CENTERLINE" SYMBOL ARE MEASURED TO:

CENTERLINE OF PARTITION ASSEMBLY (EXCLUSIVE OF ANY APPLIED

FINISHES HAVING THICKNESS WHICH MAY BE ADDED TO SUCH

WALLS) AT PARTITIONS FRAMED WITH METAL STUDS. REFER TO

"PARTITION SCHEDULE" TO DETERMINE THICKNESS OF EACH

PARTITION TYPE.

CENTERLINE OF DOOR, WINDOW, OR LOUVER OPENING.

CENTERLINE OF OTHER FEATURES AS INDICATED.

A.

DIMENSIONS UTILIZING THE "FACE OF" SYMBOL ARE MEASURED TO:

FACE OF PARTITION ASSEMBLY (EXCLUSIVE OF ANY APPLIED

FINISHES HAVING THICKNESS WHICH MAY BE ADDED TO SUCH WALL)

AS DEFINED BY THE PARTITION SCHEDULE. UNLESS NOTED AS A

"FACE OF FINISH" OR "CLEAR" DIMENSION (SEE NOTE "E" BELOW),

DIMENSIONS ARE NOT MEASURED TO THE FACE OF APPLIED FINISH.

REFER TO THE "PARTITION SCHEDULE" TO DETERMINE THE

THICKNESS OF EACH PARTITION TYPE.

B.

WHERE "EQUAL" DIMENSIONS ARE USED ON REFLECTED CEILING PLANS TO

LOCATE CEILING GRID WORK POINTS, MEASURE DIMENSIONS TO:

EDGE OF THE INDICATED CEILING AT THE FACE OF THE ADJACENT

APPLIED FINISH MEASURED AT THE PLANE OF THE CEILING.

CAUTION: DUE TO THE POSSIBLE APPLICATION OF APPLIED FINISHES -

THICKNESS OF WHICH MAY VARY BETWEEN FLOOR AND CEILING AND

IS NOT ACCOUNTED FOR (EXCEPT AS INDICATED BY "FOF" OR

"CLEAR") BY THE DIMENSION SHOWN ON THE FLOOR PLANS -THE

CONTRACTOR MUST ADJUST AS NECESSARY, THE FLOOR PLAN

DIMENSIONS TO REFLECT THE ACTUAL DIMENSIONS FOUND AT PLANE

OF THE CEILING.

C.

WHERE WALLS AND/OR PARTITIONS OF UNEQUAL THICKNESS ABUT,

ALIGN EXPOSED FACES, UNLESS OTHERWISE NOTED.

4.

ALIGN

DIMENSION, WHEN OCCURS

WHERE OPENINGS IN WALLS (SUCH AS INTERIOR WINDOWS OR DOORS) ARE

NOT DIMENSIONED BUT SHOWN AS BEING IN THE CENTER OF A GIVEN WALL

SURFACE, LOCATE OPENINGS AS GRAPHICALLY REPRESENTED.

5.

DISCIPLINE REFERENCES

DRAWING NUMBERING

DRAWING REFERENCE

GENERAL NOTES

REF. 1/1-A1

BUILDING SECTION

RE: 1/AS-126

SHEET NUMBER

DIMENSIONING CONVENTIONS ARCHITECTURAL FLOOR PLAN SYMBOLS

A

COLUMN GRID

NORTH ARROW

REVISION NUMBER AND EXTENT

KEYED NOTE MARK

-SEE CORRESPONDING

NUMBERED KEY NOTE ON SHEET WHERE

REFERENCE OCCURS

REVISION NUMBER -SEE

REVISION HISTORY ON THE

TITLE BLOCK OF EACH SHEET

EXTENT OF CURRENT REVISION

1-A26

1-A26

CL

DEMOLITION LINE

ELEVATION INDICATOR

CENTER LINE INDICATOR

EXISTING TO REMAIN LINE

FEATURES ABOVE LINE INDICATOR

BREAK, ROUND (USER DEFINES SIZE)

BREAK, STRAIGHT (SEE SECTION INDICATORS,

BUILDING, WITH BREAK STANDARDS)

DETAIL INDICATOR

DETAIL INDICATOR

DIMENSION LINE

CENTER LINE

GIGENERAL INFORMATION

AARCHITECTURAL

FPFIRE PROTECTION

PPLUMBING

MMECHANICAL

EELECTRICAL

TTECHNOLOGY

AS-100

DISCIPLINESHEET NUMBER

LOCATION MAP -NTS

CONSTRUCTION LIMITS

N

EXISTING TO REMAIN

CONCRETE

MASONRY

BUILDING INTERIOR

MATERIAL GRAPHICS

GYP BDRIGID INSULATION

WOOD EARTH

BATT INSULATION

DESIGN MANUALS:

-PG-18-1 MASTER CONSTRUCTION SPECIFICATIONS

-PG-18-3 DESIGN AND CONSTRUCTION PROCEDURES

-PG-18-5 EQUIPMENT LIST GUIDES

-PG-18-8 SEISMIC DESIGN HANDBOOK

-PG-18-10 DESIGN MANUALS

-VA PHYSICAL SECURITY DESIGN MANUAL FOR MISSION CRITICAL FACILITIES

-VA DESIGN GUIDELINES FOR ELEVATORS

-VA ARCHITECTURAL DESIGN MANUAL

-VA MECHANICAL DESIGN MANUAL

-VA ELECTRICAL DESIGN MANUAL

-VA PLUMBING DESIGN MANUAL

-VA FIRE PROTECTION DESIGN MANUAL

APPLICABLE CODES AND REGULATIONS:

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL CURRENT APPLICABLE CODES AND STANDARDS.

IN ADDITION TO ALL DEPARTMENT OF VETERANS AFFAIRS, LOCAL, AND STATE CODES, ALL WORK SHALL COMPLY WITH THE ACCESSIBILITY REQUIREMENTS OF THE STATE OF TEXAS AND THE DEPARTMENT OF VETERANS AFFAIRS GUIDELINES, ABA (ARCHITECTURAL BARRIERS ACT) ACCESSIBILITY STANDARD FOR FEDERAL FACILITIES.

APPLICABLE CODES AND STANDARDS (LATEST EDITIONS) INCLUDE:

-ABA ACCESSIBILITY STANDARDS (2015)

-NFPA 101, "LIFE SAFETY CODE" (2018)

-NFPA 10, "PORTABLE FIRE EXTINGUISHERS" (2018)

-NFPA 13, "INSTALLATION OF SPRINKLER SYSTEMS" (2019)

-NFPA 70, "NATIONAL ELECTRICAL CODE (NEC)" (2017)

-NFPA 72, "NATIONAL FIRE ALARM CODE" (2019)

-NFPA 90A, "INSTALLATION OF AIR CONDITIONING AND VENTILATION SYSTEMS" (2018)

-NFPA 99, "INSTALLATION FOR HEALTH CARE FACILITIES" (2018)

-NFPA 220, "TYPES OF BUILDING CONSTRUCTION" (2018)

-NFPA 241, "STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS" (2019)

-INTERNATIONAL BUILDING CODE (IBC) (2018)

-INTERNATIONAL MECHANICAL CODE (IMC) (2018)

-INTERNATIONAL PLUMBING CODE (IPC) (2018)

-INTERNATIONAL ENERGY CONSERVATION CODE (2018)

N

CLOSED CELL SPRAY

FOAM INSULATION

KEY PLAN -NTS

PROJECT SUMMARY

N

SSTRUCTURAL

ARCHITECTURAL ABBREVIATIONS

A LABELCLASS A DOOR

A/CAIR CONDITION

A/C UNITAIR CONDITIONING UNIT

A/EARCHITECT/ENGINEER

AAMAAMERICAN ARCHITECTURAL MANUFACTURERS

ASSOCIATION

ABANCHOR BOLT

ABCAGGREGATE BASE COURSE

ACASBESTOS CEMENT OR ASPHALTIC CONCRETE

ACIAMERICAN CONCRETE INSTITUTE

ACS DRACCESS DOOR

ACS FLRACCESS FLOOR

ACS PNLACCESS PANEL

ACSTACOUSTIC

ACTACOUSTICAL CEILING TILE

ADAREA DRAIN

ADAAMERICANS WITH DISABILITIES ACT

ADCAUTOMATIC DOOR CLOSER

ADDLADDITIONAL

ADDNADDITION

ADHADHESIVE

ADJADJACENT, ADJOINING, OR ADJUSTABLE

ADMINADMINISTRATION

ADBAUTOMATIC DOOR BOTTOM

AFCABOVE FINISHED COUNTER

AFFABOVE FINISHED FLOOR

AFGABOVE FINISHED GRADE

AFSABOVE FINISHED SLAB

AGAAMERICAN GAS ASSOCIATION

AGCASSOCIATED GENERAL CONTRACTORS

AGGRAGGREGATE

AHJAUTHORITY HAVING JURISDICTION

AHRANCHOR

AHUAIR HANDLING UNIT

AIAAMERICAN INSTITUTE OF ARCHITECTS

AISCAMERICAN INSTITUTE OF STEEL

CONSTRUCTION

ALTALTERNATE

ALT NOALTERNATE NUMBER

ALUMALUMINUM

AMPAMPERE

AMTAMOUNT

ANODANODIZE

ANSIAMERICAN NATIONAL STANDARDS INSTITUTE

ANTANTENNA

APAAMERICAN PLYWOOD ASSOCIATION

APPDAPPROVED

APPROXAPPROXIMATE

APTAPARTMENT

ARAS REQUIRED

ARCHARCHITECT

ASBASBESTOS

ASIARCHITECT'S SUPPLEMENTAL INSTRUCTION

ASKLRAUTOMATIC SPRINKLER

ASPHASPHALT

ASSNASSOCIATION

ASTMAMERICAN SOCIETY FOR TESTING AND

MATERIALS

ATCHATTACHMENT

ATMAUTOMATIC TELLER MACHINE

ATSAUTOMATIC TRANSFER SWITCH

AUTOAUTOMATIC

AUXAUXILIARY

AVAUDIO VISUAL

AVEAVENUE

AVGAVERAGE

AWACID WASTE

AWIARCHITECTURAL WOODWORKING INSTITUTE

AWPAAMERICAN WOOD PRESERVERS' ASSOCIATION

AWSAMERICAN WELDING SOCIETY

AWTACOUSTICAL WALL TREATMENT

B LABELCLASS B DOOR

B PLBASE PLATE

BALCBALCONY

BATBATTEN

BBBULLETIN BOARD

BDBOARD

BD FTBOARD FEET (FOOT)

BEVBEVEL

BHMABUILDER'S HARDWARE MANUFACTURER'S

ASSOCIATION

BI FLD DRBIFOLDING DOORS

BITUMBITUMINOUS

BKGBACKING

BLDBUILD

BLDGBUILDING

BLKTBLANKET

BLVDBOULEVARD

BMBEAM OR BENCHMARK

BOTBOTTOM

BRBEDROOM

BRCGBRACING

BRDGBRIDGING

BRDG JSTBRIDGING JOIST

BRGBEARING

BRG PLBEARING PLATE

BRKTBRACKET

BRZBRONZE

BSMTBASEMENT

BTWNBETWEEN

BUBUSHEL

BURBUILT-UP ROOFING

CCELSIUS CHANNEL

CCHANNEL CELSIUS

C CONCCAST CONCRETE

C LABELCLASS C DOOR

C TO CCENTER TO CENTER

CABCABINET

CACCEILING ATTENUATION CLASS

CBCATCH BASIN OR CORNER BEAD

CBBCEMENTITIOUS (BACKER) BOARD

CCCUBIC CENTIMETER

CCTVCLOSED CIRCUIT TELEVISION

CCWCOUNTERCLOCKWISE

CDCONSTRUCTION DOCUMENTS OR CONTRACT

DOCUMENTS

CEMCEMENT

CEM PLASCEMENT PLASTER

CERCERAMIC

CFCONTRACTOR FURNISHED

CF/CICONTRACTOR FURNISHED/CONTRACTOR

INSTALLED

CF/OICONTRACTOR FURNISHED/OWNER INSTALLED

CFLGCOUNTERFLASHING

CFMCUBIC FEET PER MINUTE

CFMFCOLD-FORMED METAL FRAMING

CFSCUBIC FEET PER SECOND

CGCENTER OF GRAVITY OR CORNER GUARD

CGSFUCERAMIC GLAZED STRUCTURAL FACING UNITS

CH BDCHALKBOARD

CHEMCHEMICAL

CHFRCHAMFER

CHKCHECK

CICAST IRON

CIPCAST-IN-PLACE

CIRCIRCLE

CIRCCIRCULAR

CJCONSTRUCTION JOINT OR CONTROL JOINT

CLCENTER LINE

CLDGCLADDING

CLGCEILING

CLG HTCEILING HEIGHT

CLRCLEAR

cm²SQUARE CENTIMETER cm³CUBIC CENTIMETER

CMCONSTRUCTION MANAGEMENT

CMUCONCRETE MASONRY UNIT

CNRCORNER

CNTRCOUNTER

COCARBON MONOXIDE, CERTIFICATE OF

OCCUPANCY, CLEANOUT, OR COMPANY

CO2CARBON DIOXIDE

COLCOLUMN

COMCOMMON

COMBCOMBINATION, COMBINED

COMMCOMMUNICATION

COMPCOMPONENT

CONCCONCRETE

CONC FLRCONCRETE FLOOR

CONDCONDENSER OR CONDITION

CONFCONFERENCE

CONNCONNECT

CONSTRCONSTRUCTION

CONTCONTINUE

CONTRCONTRACTOR

COORDCOORDINATE

CORRCORRIDOR

CPMCRITICAL PATH METHOD

CPRSCOMPRESSIBLE

CPTCARPET

CRSCOLD ROLLED STEEL

CRSICONCRETE REINFORCING STEEL INSTITUTE

CSBCONCRETE SPLASH BLOCK

CSGCASING

CSICONSTRUCTION SPECIFICATIONS INSTITUTE

CSKCOUNTER SUNK

CSMTCASEMENT

CSWKCASEWORK

CTCERAMIC TILE

CTBCERAMIC TILE BASE

CTFCERAMIC TILE FLOOR

CTGCOATING

CTRCENTER CONTOUR

CTRLCONTROL

CTVCABLE TELEVISION

CUCOPPER C

CU FTCUBIC FEET

CU INCUBIC INCH

CU YDCUBIC YARD

CURTCURTAIN

CYLCYLINDER

CYL LCYLINDER LOCK

DDEPTH OR PENNY (NAIL)

D LABELCLASS D DOOR

DATDATUM

DBDECIBEL

DBLDOUBLE

DBL GLZDOUBLE GLAZE

DCDIRECT CURRENT

DEGDEGREE

DELDELETE

DEMODEMOLITION

DEPTDEPARTMENT

DETDETAIL

DFELECTRIC WATER COOLER

DIADIAMETER

DIAGDIAGONAL DIAGRAM

DIAGDIAGRAM DIAGONAL

DIFFDIFFERENCE OR DIFFUSER

DIMDIMENSION

DIRDIRECTION

DISPDISPENSER

DISTDISTANCE

DIVDIVIDE OR DIVISION

DLDEAD LOAD

DOCDOCUMENT

DOUG FIRDOUGLAS FIR

DOZDOZEN

DRDOOR, DRAIN, DRESSING ROOM, OR DRIVE

DR CLDOOR CLOSER

DR FRDOOR FRAME

DR OPNGDOOR OPENING

DSDOWNSPOUT

DSGNDESIGN

DWDISHWASHER

DWGDRAWING

DWTRDUMBWAITER

EEAST

E LABELCLASS E DOOR

EAEACH

EFFEFFICIENCY

EFSEXTERIOR FINISH SYSTEM

EIFSEXTERIOR INSULATION AND FINISH SYSTEM

EJEXPANSION JOINT

ELELEVATION

ELASTELASTOMERIC

ELECELECTRIC

ELEC DR OPELECTRIC DOOR OPENER

ELEVELEVATOR

EMEREMERGENCY

EMER SHREMERGENCY SHOWER

ENCLENCLOSURE

ENGRENGINEER

ENVIRENVIRONMENT

EPAENVIRONMENTAL PROTECTION AGENCY

EPDMETHYLENE PROPYLENE DIENE MONOMER

EPOEMERGENCY POWER OFF

EPSEXPANDED POLYSTYRENE BOARD (INSULATION)

EQEQUAL

EQL SPEQUALLY SPACED

EQUIPEQUIPMENT

EQUIVEQUIVALENT

ERDEXISTING ROOF DRAIN

ESCESCAPE OR ESCUTCHEON

ESCALESCALATOR

ESMTEASEMENT

ESPESPECIALLY

ESTESTIMATE

ETCAND SO FORTH OR ET CETERA

EWEACH WAY

EWCELECTRIC WATER COOLER

EWSEYE WASH STATION

EXHEXHAUST

EXISTEXISTING

EXPEXPANSION OR EXPOSED

EXP BTEXPANSION BOLT

EXST GREXISTING GRADE

EXTEXTERIOR, EXTERNAL, OR EXTINGUISHER

EXT GREXTERIOR GRADE

FFAHRENHEIT OR FEMALE

FAFIRE ALARM

FABFABRIC

FACFACTOR

FACILFACILITY

FASFASCIA

FAS BDFASCIA BOARD

FCOFLOOR CLEANOUT

FCTYFACTORY

FDFLOOR DRAIN

FDCFIRE DEPARTMENT CONNECTION

FDTNFOUNDATION

FEFIRE EXTINGUISHER

FECFIRE EXTINGUISHER CABINET

FFFINISH FACE

FF ELFINISH FLOOR ELEVATION

FF&EFURNITURE, FIXTURE, AND EQUIPMENT

FHFLAT HEAD OR FLAT HEAD SCREWS

FHCFIRE HOSE CABINET

FHMSFLAT HEAD MACHINE SCREW

FHPFULL HEIGHT PARTITION

FHWSFLAT HEAD WOOD SCREW

FIGFIGURE

FILFILLET

FINFINISH

FIN FLRFINISH FLOOR

FIN GRFINISH GRADE

FIN WDFINISH WOOD

FIXTFIXTURE

FLFLOORLINE

FLASHFLASHING

FLDGFOLDING

FLEXFLEXIBLE

FLGFLOORING

FLRFLOOR

FLR FINFLOOR FINISH

FLR SKFLOOR LAVATORY

FLUORFLUORESCENT

FLUOR FIXFLUORESCENT FIXTURE

FMFACTORY MUTUAL

FM-GFACTORY MUTUAL GLOBAL

FOFINISHED OPENING

FOCFACE OF CONCRETE OR FACE OF CURB

FOFFACE OF FINISH

FOMFACE OF MASONRY

FOSFACE OF SLAB OR FACE OF STUD

FOUNTFOUNTAIN

FOWFACE OF WALL

FPFIRE PROTECTION OR FIREPROOF

FPMFEET PER MINUTE

FPSFEET PER SECOND

FRFIRE RATING, FIRE RESISTANT, OR FRAME

FR SNKFLUSHING RIM LAVATORY

FREQFREQUENCY

FRMGFRAMING

FRPFIBER REINFORCED POLYESTER OR

FIBERGLASS REINFORCED PLASTIC

FRZFREEZER

FSFEDERAL SPECIFICATION

FSTNRFASTENER

FTFEET OR FOOT

FTGFOOTING

FURGFURRING

FURNFURNISH OR FURNITURE

FUTFUTURE

FWCFABRIC WALLCOVERING

GAGAGE OR GYPSUM ASSOCIATION

GALGALLON

GALVGALVANIC OR GALVANIZED

GALV STLGALVANIZED STEEL

GBGRAB BAR

GCGENERAL CONTRACTOR

GDGUARD

GDRGUARD RAIL

GENGENERAL OR GENERATOR

GFRCGLASS-FIBER-REINFORCED CONCRETE

GFRGGLASS-FIBER-REINFORCED GYPSUM

GFRPGLASS-FIBER-REINFORCED PLASTIC

GIGALVANIZED IRON

GLGLASS

GL BLKGLASS BLOCK

GLU LAMGLUED LAMINATED WOOD

GR FLGROUND FLOOR

GRANGRANITE

GRTGGRATING

GSBGYPSUM SHEATHING BOARD

GSMGALVANIZED SHEET METAL

GSUGLAZED STRUCTURAL UNIT

GTGROUT

GUARGUARANTEE

GUTGUTTER

GYPGYPSUM

GYP BDGYPSUM BOARD

GYP PLASGYPSUM PLASTER

HHIGH

H PLAMHIGH PRESSURE PLASTIC LAMINATE

HAZ MATHAZARDOUS MATERIALS

HBHOSE BIBB

HCHOLLOW CORE

HCWDHOLLOW CORE WOOD DOOR

HDBDHARDBOARD

HDNRHARDENER

HDOHIGH DENSITY OVERLAY

HDRHEADER

HDWHARDWARE

HDWDHARDWOOD

HEPAHIGH EFFICIENCY PARTICULATE AIR (FILTER)

HEXHEXAGON

HFHIGH FREQUENCY

HGRHANGER

HMHECTOMETER

HMHOLLOW METAL

HMDHOLLOW METAL DOOR

HMDFHOLLOW METAL DOOR AND FRAME

HMFHOLLOW METAL FRAME

HNDRLHANDRAIL

HOHOLD OPEN

HORIZHORIZONTAL

HOSPHOSPITAL

HPHIGH PRESSURE OR HORSEPOWER

HQHEADQUARTERS

HSHEAT-STRENGTHENED (GLASS) OR HIGH

STRENGTH

HSEHOUSE

HSKPGHOUSEKEEPING

HSTHOIST

HTHEIGHT

HVACHEATING, VENTILATING, AND AIR CONDITIONING

HVYHEAVY

HWHOT WATER

HYDHYDRANT

HYDRHYDRAULIC

IINTERSTATE (HIGHWAY) OR MOMENT OF

INERTIA

IAQINDOOR AIR QUALITY

IBCINTERNATIONAL BUILDING CODE

IDIDENTIFICATION, INSIDE DIAMETER, OR

INTERIOR DESIGN

ID NOIDENTIFICATION NUMBER

ILLUMILLUMINATION

INCLINCLUDED

INDINDEPENDENT OR INDUSTRIAL

INFOINFORMATION

INSULINSULATION

INTINTERIOR

INTERCOMINTERCOMMUNICATION

INTLINTERNATIONAL

IRMAINVERTED ROOF MEMBRANE ASSEMBLY

IWHINSTANTANEOUS WATER HEATER

JANJANITOR

J-BOXJUNCTION BOX

KDKILN DRIED OR KNOCKED DOWN

KITKITCHEN

KOKNOCKOUT

KPLKICKPLATE

LANGLE

LABLABORATORY

LADLADDER

LAMLAMINATE

LAM GLLAMINATED GLASS

LAULAUNDRY

LAVLAVATORY

LBRLUMBER

LBSPOUND

LD BRGLOAD-BEARING

LDRLEADER

LEDLIGHT EMITTING DIODE

LFLINEAR FEET (FOOT)

LHLEFT HAND

LHRLEFT HAND REVERSE

LHRLEFT HAND REVERSE LATENT HEAT RATIO

LIBLIBRARY

LINLINEAR

LINOLINOLEUM

LIQLIQUID

LKRLOCKER

LKR RMLOCKER ROOM

LKWASHLOCKWASHER

LLLEAD LINED

LLHLONG LEG HORIZONTAL

LLVLONG LEG VERTICAL

LMSTLIMESTONE

LNDSCPLANDSCAPE

LRLIVING ROOM

LRGLARGE

LRVLOUVERED ROOF VENT

LSLUMP SUM

LTLIGHT

LT GALIGHT GAGE

LT WTLIGHTWEIGHT

LTGLIGHTING

LTNGLIGHTNING

LVDLOUVERED

LVRLOUVER

LWCLIGHTWEIGHT CONCRETE

LWICLIGHTWEIGHT INSULATING CONCRETE

LYRLAYER

MACHMACHINE

MACH RMMACHINE ROOM

MAINTMAINTENANCE

MANMANUAL

MATLMATERIAL

MATVMASTER ANTENNA TELEVISION SYSTEM

MAXMAXIMUM

MBMACHINE BOLT

MCBMETAL CORNER BEAD

MDDECK

MEMECHANICAL ENGINEER

MEASMEASURE

MECHMECHANICAL

MECH RMMECHANICAL ROOM

MEDMEDICAL MEDIUM

MEDMEDIUM MEDICAL

MEKMETHYL ETHYL KETONE

MELMELAMINE

MEMBMEMBRANE

MEMOMEMORANDUM

MEZZMEZZANINE

MFMILL FINISH

MFDMANUFACTURED

MFGMANUFACTURING

MFRMANUFACTURER

MFR RECMANUFACTURER'S RECOMMENDATION

MGTMANAGEMENT

MHMANHOLE

MICMICROPHONE

MIDMIDDLE

MIL STDMILITARY STANDARD

MINMINIMUM MINUTE

MINMINUTE MINIMUM

MIRRMIRROR

MISCMISCELLANEOUS

MITMITER

MKRMARKER

MLMETAL LATH

MLDGMOLDING (MOULDING)

MLWKMILLWORK

mmMILLIMETER

MOMASONRY OPENING OR MOTOR OPERATED

MODMODEL, MODIFY OR MODULE

MOD BITMODIFIED BITUMEN

MONMONITOR

MOPRMOP RACK

MRMOISTURE RESISTANT

MSMACHINE SCREW OR MOP LAVATORY

MTDMOUNTED

MTGMOUNTING

MTLMETAL

MULLMULLION

MWMICROWAVE

MWPMEMBRANE WATERPROOFING

NNORTH

NANOT APPLICABLE

NAAMMNATIONAL ASSOCIATION OF ARCHITECTURAL

METAL MANUFACTURERS

NATNATURAL

NATLNATIONAL

NCNOISE CRITERIA

NCOMBLNONCOMBUSTIBLE

NECNATIONAL ELECTRICAL CODE

NEGNEGATIVE

NEMANATIONAL ELECTRICAL MANUFACTURERS

ASSOCIATION

NEUTNEUTRAL

NFCNATIONAL FIRE CODE

NFPANATIONAL FIRE PROTECTION ASSOCIATION

NICNOT IN CONTRACT

NONUMBER

NOMNOMINAL

NRNOISE REDUCTION

NRCNOISE REDUCTION COEFFICIENT

NRCANATIONAL ROOFING CONTRACTORS

ASSOCIATION

NRPNONREMOVABLE

NSNARROW STILE

NUMNUMERAL

O/OOUT TO OUT

OOXYGEN

OAOUTSIDE AIR OR OVERALL

OCON CENTER

OCCOCCUPY

OCTOCTAGON

ODOUTSIDE DIAMETER OUTSIDE DIMENSION

ODOUTSIDE DIMENSION OUTSIDE DIAMETER

OF/CIOWNER FURNISHED/CONTRACTOR INSTALLED

OFDOVERFLOW DRAIN

OFFOFFICE

OF/OIOWNER FURNISHED/OWNER INSTALLED

OHOVERHANG

OH DROVERHEAD (COILING) DOOR

OPHOPPOSITE HAND

OPNGOPENING

OPPOPPOSITE

OPROPERABLE

OPTOPTIONAL

OROPERATING ROOM OR OUTSIDE RADIUS

ORDORDNANCE OR OVERFLOW ROOF DRAIN

ORGORGANIC

ORIGORIGINAL

ORNORNAMENTAL

OSHAOCCUPATIONAL SAFETY AND HEALTH

ADMINSTRATION

OUTOUTLET

OZOUNCE

PARPARALLEL OR PARAPET

PARAPARAGRAPH

PARTPARTIAL

PATPATTERN

PBPUSHBUTTON

PBDPARTICLEBOARD

PCPIECE, POLYCARBONATE OR PORTLAND

CEMENT

PCAPORTLAND CEMENT ASSOCIATION

PCCPRECAST CONCRETE

PCCPCONCRETE PAVEMENT

PCDPAPER CUP DISPENSER

PCFPOUNDS PER CUBIC FOOT

PCPPORTLAND CEMENT PLASTER

PEDPEDESTAL

PENPENETRATE

PENDPENDANT

PERFPERFORATED

PERIMPERIMETER

PERPPERPENDICULAR

PGBDPEGBOARD

PHARPHARMACY

PHOTOPHOTOGRAPH

PHSPHILLIPS HEAD SCREW

PKGPACKAGE

PLPROPERTY LINE

PL GLPLATE GLASS

PLAMPLASTIC LAMINATE

PLASPLASTER OR PLASTIC

PLBGPLUMBING

PLYWDPLYWOOD

PMTLPAINTED METAL

PNEUPNEUMATIC

PNLPANEL

POPOST OFFICE PURCHASE ORDER

POPURCHASE ORDER POST OFFICE

POLYPOLYETHYLENE (PLASTIC)

PRPAIR

PRCSTPRECAST

PREFABPREFABRICATE

PREFINPREFINISH

PRELIMPRELIMINARY

PREPPREPARATION

PRESSPRESSURE

PREVPREVIOUS

PRKGPARKING

PRMLDPREMOLDED

PROJPROJECT

PROPPROPERTY

PSFPOUNDS PER SQUARE FOOT

PSIPOUNDS PER SQUARE INCH

PTPAINT, PNEUMATIC TUBE, OR PRESSURE

TREATED

PTDPAPER TOWEL DISPENSER

PTNPARTITION

PVCPOLYVINYL CHLORIDE (PLASTIC)

PVGPAVING

PWRPOWER

QAQUALITY ASSURANCE

QCQUALITY CONTROL

QRYQUARRY

QTQUARRY TILE

QTBQUARRY TILE BASE

QTFQUARRY TILE FLOOR

QTRQUARTER

QTYQUANTITY

QUADQUADRANT

QUALQUALITY

RRADIUS OR RISER

RARETURN AIR

RADRADIATOR

RBRESILIENT BASE OR RUBBER BASE

RB HKROBE HOOK

RBMREINFORCED BRICK MASONRY

RBRRUBBER

RCREMOTE CONTROL

RCPREFLECTED CEILING PLAN

RCVRRECEIVER

RDROAD OR ROOF DRAIN

RECRECESSED

RECDRECEIVED

RECPTRECEPTACLE

RECTRECTANGLE

REFREFERENCE OR REFRIGERATOR

REFRREFRACTORY REFRIGERATION

REFRREFRIGERATION REFRACTORY

REGREGISTER

REINFREINFORCE

REPREPAIR

REPLREPLACE

REQREQUIRE

REQDREQUIRED

RESILRESILIENT

RETRETURN

REVREVISION

RFRADIO FREQUENCY

RFGROOFING

RFIREQUEST FOR INFORMATION

RFPREQUEST FOR PROPOSAL

RHRIGHT HAND

RHMSROUND HEAD MACHINE SCREW

RHRRIGHT HAND REVERSE

RHWSROUND HEAD WOOD SCREW

RLROOF LEADER

RLGRAILING

RMROOM

RNDROUND

ROROUGH OPENING

ROWRIGHT OF WAY

RPMREVOLUTIONS PER MINUTE

RSROUGH SAWN

RTRIGHT

RVROOF VENT

RVSREVERSE

RWDREDWOOD

RWLRAIN WATER LEADER

SASUPPLY AIR

SALVSALVAGE

SAMPSAMPLE

SANSANITARY

SATSUSPENDED ACOUSTICAL TILE

SATCSUSPENDED ACOUSTICAL TILE CEILING

SBSPLASH BLOCK

SBSSTYRENE BUTADIEN STYRENE

SBSTRSUBSTRATE

SCSHADING COEFFICIENT OR SOLID CORE

SCHSCHOOL

SCHEDSCHEDULE

SCHEMSCHEMATIC

SCPSCUPPER

SCRNSCREEN

SCTSTRUCTURAL CLAY TILE

SCWDSOLID CORE WOOD DOOR

SDSHOP DRAWINGS, SMOKE DETECTOR, OR

SOAP DISPENSER;

SDGSIDING

SECTSECTION

SEGSEGMENT

SELSELECT

SEPSEPARATE

SFSQUARE FOOT (FEET)

SFTWDSOFTWOOD

SGDSLIDING GLASS DOOR

SGLSINGLE

SHRSHOWER

SHR HDSHOWER HEAD

SHRDSHOWER DRAIN

SHTSHEET

SHT MTL FLASHSHEET METAL (FLASHING)

SHTHGSHEATHING

SHVSHELVING

SIMSIMILAR

SJSCORED JOINT

SJISTEEL JOIST INSTITUTE

SKSKETCH

SKLTSKYLIGHT

SLD WDWHORIZONTAL SLIDING WINDOW

SLDGSLIDING

SLNTSEALANT

SMSHEET METAL

SMKSMOKE

SNDSANITARY NAPKIN DISPENSER

SND INSSOUND INSULATION

SNDUSANITARY NAPKIN DISPOSAL UNIT

SPECSPECIFICATION

SPKLRSPRINKLER

SPKRSPEAKER

SPLYSUPPLY

SQSQUARE

SQ INSQUARE INCH

SQ YDSQUARE YARD

SSSANITARY SEWER OR SERVICE LAVATORY

SSTSTAINLESS STEEL

STSTAIRS OR STREET

STCSOUND TRANSMISSION CLASS

STDSTANDARD

STIFSTIFFENER

STL JSTSTEEL JOIST

STL LNTLSTEEL LINTEL

STL PLSTEEL PLATE

STL RF DKSTEEL ROOF DECK

STL TBSTEEL TUBE

STL TRSTEEL TRUSS

STNLSSTAINLESS

STORSTORAGE

STRSTRINGERS

STRUCTSTRUCTURAL

STRUCT STLSTRUCTURAL STEEL

SUBSUBSTITUTE

SURFSURFACE

SUSPSUSPEND

SUSP CLGSUSPENDED CEILING

SVSHEET VINYL

SWSWITCH

SWDRSWING DOOR

SYMSYMBOL

SYNTHSYNTHETIC

SYSSYSTEM

TTREAD

T&GTONGUE AND GROOVE

T&MTIME AND MATERIALS

TBTHROUGH BOLT OR TOWEL BAR

TCATILE COUNCIL OF AMERICA

TCPTELEPHONE CONTROL PANEL TEMPERATURE

CONTROL PANEL; TRAFFIC CONTROL PLAN

TDTOWEL DISPENSER

TECHTECHNICAL

TELTELEPHONE

TEMPTEMPERATURE OR TEMPORARY

TERTERRAZZO

THDTHREAD

THERMTHERMAL

THKTHICKNESS

THRESTHRESHOLD

THRUTHROUGH

THRUOUTTHROUGHOUT

TK BDTACKBOARD

TMPDTEMPERED

TMPD GLTEMPERED GLASS

TNTRUE NORTH

TOTOP OF ___

TO FDNTOP OF FOUNDATION

TOBTOP OF BEAM

TOMTOP OF MASONRY

TOPTOP OF PARAPET

TOSTOP OF STEEL

TOWTOP OF WALL

TPDTOILET PAPER DISPENSER

TPHTOILET PAPER HOLDER

TRTOWEL RACK

TRANSTRANSOM

TRANS WD FINTRANSPARENT WOOD FINISH

TRTDTREATED

TSTENSILE STRENGTH OR TUBE STEEL

TSTATTHERMOSTAT

TVTELEVISION

TYPTYPICAL

UHEAT TRANSFER COEFFICIENT

UCUNDERCUT

UCDUNDERCUT DOOR

UGNDUNDERGROUND

ULUNDERWRITERS LABORATORIES

ULTULTIMATE

UNFINUNFINISH

UONUNLESS OTHERWISE NOTED

UPSUNINTERRUPTIBLE POWER SUPPLY

URURINAL

UTILUTILITY

UVULTRAVIOLET

VVOLT

VACVACUUM

VARVARIES

VCTVINYL COMPOSITION TILE VITRIFIED CLAY TILE

VEHVEHICLE

VENTVENTILATION

VERTVERTICAL

VESTVESTIBULE

VFATVINYL FACED ACOUSTICAL TILE

VICVICINITY

VIDVIDEO

VIFVERIFY IN FIELD

VNRVENEER

VOCVOLATILE ORGANIC COMPOUND

VOLVOLUME

VOLTVOLTAGE

VPVENEER PLASTER

VRVAPOR RETARDER

VTRVENT THROUGH ROOF

VWCVINYL WALL COVERING

VWFVINYL WALL FABRIC

WWIDE OR WEST

W/WITH

W/OWITHOUT

WARRWARRANTY

WBLWOOD BLOCKING

WCWALL COVERING OR WATER CLOSET

WC WL HNGWATER CLOSET, WALL HUNG

WCHRWATER CHILLER

WCL WL MTDWATER COOLER, WALL HUNG

WDWOOD

WDWWINDOW

WFWIDE FLANGE

WFABWALL FABRIC

WFRWOOD FRAME

WFSWOOD FURRING STRIPS

WHWATER HEATER

WHSEWAREHOUSE

WLDWELDED

WMWIRE MESH

WPWATERPROOFING

WPDWATER PRESSURE DROP

WPMWATERPROOF MEMBRANE

WRWEATHER RESISTANT

WSWEATHERSTRIP

WSCTWAINSCOT

WTWEIGHT

WWFWELDED WIRE FABRIC

X BRACECROSS BRACE

XPSEXTRUDED POLYSTYRENE BOARD (INSULATION)

YDYARD

YRYEAR

UNO

ACMASBESTOS CONTAINING MATERIAL

ACPACRYLIC GLAZING

CORCONTRACTING OFFICER'S REPRESENTATIVE

WPRWALL PROTECTION / RAILING

Project

Building

Drawing

Project Title

Location

Issue DateCheckedDrawn

Drawing

Approve

VA FORM 08 -

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

2 14567891

Phase

PROJECT MANAGEMENTSTAMP CONSULTANT

3 2 14567891

FULLY

SPRINKLERED

4G

INTERIORS

Austin, Texas 78746

ARCHITECTURE

5121 Bee Caves Road, Suite 203

T:512 -327 -4149

COX DESIGN ASSOCIATES

PLANNING

F:512 -327 -7679

Austin bcox@coxdesignassociates.com09/10/2020

BIM

360://ALM

VAH

4G

C

AN

C

ER

C

EN

TER

/ALM

VAH

_4G

C

AN

C

ER

C

EN

TER

_C

D

_AR

C H

_08182020.rvt

9/10/2020 4:34:50 PM

GI-003

CONSTRUCTION

DOCUMENTS -100%

ARCHITECTURAL

ABBREVIATIONS

CONSTRUCT 4G CANCER

CENTER

7400 MERTON MINTER BLVD.

SAN ANTONIO, TX. 78229

09/10/2020RHCMAG

671-250

60"

MIN.

60"

MIN.

A. MINIMUM CLEAR WIDTH FOR TWO

WHEELCHAIRS

B. MINIMUM CLEAR WIDTH FOR SINGLE

WHEELCHAIR

M

IN

PR

E F

ER

R

E D

M

IN

W

IT

H

PA

R

TI

TI

O

N S

" M

IN

PR

E F

ER

R

E D

M

IN

W

TI

TI

O N

S

" M

IN

PR

E F

ER

R

E D

M

IN

W

TI

TI

O N

" M

IN

M

IN

48"

MIN

DOOR

WIDTH

DOOR

WIDTH

48"

MIN

DOOR

WIDTH

60"

MIN

ABC

M

IN

C O

N

TI

N O

U S

PO

IN

T24

M

AX

60"

MIN.

60"

MIN

A. MINIMUM TURNING

SPACE

B.MINIMUM CLEAR

WIDTH

M

IN

> 24

M

IN

12 "

M

IN

30"

MIN

30"

MIN

15"

A. FORWARD

APPROACH

B. SIDE

APPROACH

" M

IN

60"

MIN

SPACE NEEDED TO TURN A

WHEELCHAIR

M

IN42

M

IN

M

IN

54"

MIN

56"

MIN

24"

MIN

32" MIN

CLR

32" MIN

CLR

46" MIN

CLR

A. FRONT

APPROACH

B. SIDE

APPROACH

C. LATCH SIDE

APPROACH

46" MIN

CLR

32" MIN

CLR

36" MIN

CLR

M

IN

30"

MIN

M

IN

M

IN

7/

M

IN

ACCESSIBLE PATH OF TRAVELACCESSIBLE PATH OF TRAVEL

30"

MIN

42"

MIN

2' - 11" 30"

MIN

48"

MIN

5' - 0"

A. CLEARANCES FOR

SEATINGB. CLEARANCES FOR

TABLES

19"

MIN

5' -0"

MIN.

base

1' -0"

MIN.

3' -0"

MIN.

1' -0"

MIN.

M

IN

3'

0"

M

IN

.ar m ar m

5'

Project

Building

Drawing

Project Title

Location

Issue DateCheckedDrawn

Drawing

Approve

VA FORM 08 -

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

2 14567891

Phase

PROJECT MANAGEMENTSTAMP CONSULTANT

3 2 14567891

FULLY

SPRINKLERED

4G

INTERIORS

Austin, Texas 78746

ARCHITECTURE

5121 Bee Caves Road, Suite 203

T:512 -327 -4149

COX DESIGN ASSOCIATES

PLANNING

F:512 -327 -7679

Austin bcox@coxdesignassociates.com09/10/2020

BIM

360://ALM

VAH

4G

C

AN

C

ER

C

EN

TER

/ALM

VAH

_4G

C

AN

C

ER

C

EN

TER

_C

D

_AR

C H

_08182020.rvt

9/10/2020 4:34:53 PM

GI-004

CONSTRUCTION

DOCUMENTS -100%

ACCESSIBILITY STANDARDSCONSTRUCT 4G CANCER

CENTER

7400 MERTON MINTER BLVD.

SAN ANTONIO, TX. 78229

09/10/2020RHCMAG

671-250

SCALE: NTS 1MINIMUM CORRIDOR WIDTH

SCALE: NTS 2TWO HINGED DOORS IN A SERIES

SCALE: NTS 3MINIMUM CLEAR WIDTH/ TURNING SPACE

SCALE: NTS 4MANEUVERING CLEARANCE AT ALCOVES

SCALE: NTS 6WHEELCHAIR TURNING RADIUS

SCALE: NTS 5SLIDING FOLDING DOOR APPROACH

SCALE: NTS 7CLEAR FLOOR GROUND SPACE

SCALE: NTS 9MINIMUM CLEARANCES FOR SEATING & TABLES

SCALE: NTS 8T-SHAPED TURNING SPACE

8"

MIN.

25"

MAX.

(A) ELEVATION11"

MIN.

(B) PLAN

2'

4"

AX

M

IN

17-2 5"

(A) ELEVATION(B) PLAN

2'

6"

(A)(B)

2'

M

AX

4'

2'

M

AX

3'

M

AX

20"

MAX.

>20-25"

MAX

(A)(B)

M

AX

M

AX

M

IN

M

AX

1'

3"

4'

1' -8 1/2"

1' -0 1/2"

A. PULL SIDEB. PUSH SIDEC. PUSH SIDE, DOOR PROVIDED

WITH BOTH CLOSER AND LATCH

5'

0"

8 "

8 "

4'

0"

8 "

4'

0"

24"

MAX.

48"

MIN.

24"

MAX.

M

IN

Project

Building

Drawing

Project Title

Location

Issue DateCheckedDrawn

Drawing

Approve

VA FORM 08 -

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

2 14567891

Phase

PROJECT MANAGEMENTSTAMP CONSULTANT

3 2 14567891

FULLY

SPRINKLERED

4G

INTERIORS

Austin, Texas 78746

ARCHITECTURE

5121 Bee Caves Road, Suite 203

T:512 -327 -4149

COX DESIGN ASSOCIATES

PLANNING

F:512 -327 -7679

Austin bcox@coxdesignassociates.com09/10/2020

BIM

360://ALM

VAH

4G

C

AN

C

ER

C

EN

TER

/ALM

VAH

_4G

C

AN

C

ER

C

EN

TER

_C

D

_AR

C H

_08182020.rvt

9/10/2020 4:34:56 PM

GI-005

CONSTRUCTION

DOCUMENTS -100%

ACCESSIBILITY STANDARDSCONSTRUCT 4G CANCER

CENTER

7400 MERTON MINTER BLVD.

SAN ANTONIO, TX. 78229

09/10/2020RHCMAG

671-250

SCALE: NTS 1KNEE CLEARANCE

SCALE: NTS 2TOE CLEARANCE

SCALE: NTS 3OBSTRUCTED HIGH SIDE REACH

SCALE: NTS 6OBSTRUCTED HIGH FORWARD REACH

SCALE: NTS 7UNOBSTRUCTED FORWARD REACH

SCALE: NTS 4UNOBSTRUCTED SIDE REACH

SCALE: NTS 8MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES

SCALE: NTS 5CLEAR WIDTH OF AN ACCESSIBLE ROUTE

A. FRONT OF REAR ENTRYB. SIDE ENTRY

M

IN

M

IN

36"

MIN.

33"

MIN.

33"

MIN.

A. SINGLE SPACEB. TWO SPACES

24"

MIN. 12"

MIN.

22"

MIN.

24"

MIN.

F. FRONT APPROACH, PUSH SIDE, DOOR

PROVIDEDWITH BOTH CLOSER AND

LATCH

G. HINGE APPROACH,

PUSH SIDE

H. LATCH APPROACH, PUSH

SIDE, DOOR PROVIDED WITH

CLOSER

I. LATCH APPROACH,

PUSH SIDE

J. FRONT APPROACH,

PUSH SIDE

22"

MIN.

18" MIN CLEAR AT INTERIOR

DOOR

PULL

SIDE

PUSH

SIDE

PULL

SIDE

PUSH

SIDE

42"

MIN

PULL

SIDE

PUSH

SIDE

24"

MIN.

A. FRONT

APPROACH

B. HINGE APPROACH,

PULL SIDE

C. LATCH SIDE APPROACH,

PULL SIDE

D. HINGE APPROACH, PUSH

SIDE, DOOR PROVIDED WITH BOTH CLOSER

AND LATCH

E. LATCH APPROACH, PULL

SIDE, DOOR PROVIDED WITH

CLOSER

M

IN

M

IN

M

IN

M

IN

M

IN

M

IN

M

IN

M

IN

36"

MIN

17" -25"

MAX

CLEARANCES FOR COUNTERS

M

IN

M

AX27

M

IN

M

AX

Project

Building

Drawing

Project Title

Location

Issue DateCheckedDrawn

Drawing

Approve

VA FORM 08 -

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

2 14567891

Phase

PROJECT MANAGEMENTSTAMP CONSULTANT

3 2 14567891

FULLY

SPRINKLERED

4G

INTERIORS

Austin, Texas 78746

ARCHITECTURE

5121 Bee Caves Road, Suite 203

T:512 -327 -4149

COX DESIGN ASSOCIATES

PLANNING

F:512 -327 -7679

Austin bcox@coxdesignassociates.com09/10/2020

BIM

360://ALM

VAH

4G

C

AN

C

ER

C

EN

TER

/ALM

VAH

_4G

C

AN

C

ER

C

EN

TER

_C

D

_AR

C H

_08182020.rvt

9/10/2020 4:34:58 PM

GI-006

CONSTRUCTION

DOCUMENTS -100%

ACCESSIBILITY STANDARDSCONSTRUCT 4G CANCER

CENTER

7400 MERTON MINTER BLVD.

SAN ANTONIO, TX. 78229

09/10/2020RHCMAG

671-250

SCALE: NTS 1CLEAR SPACE IN FRONT OF COUNTER

SCALE: NTS 3DEPTH OF WHEELCHAIR SPACES

SCALE: NTS 4WIDTH OF WHEELCHAIR SPACES

SCALE: NTS 5SWINGING DOOR APPROACH

SCALE: NTS 2MINIMUM CLEARANCE FOR COUNTER

X

X

X = TREAD DEPTH

LEVE

RS

PUSH/PU

LL

PANIC BAR EXIT

DEVICE

NOTE: DOOR HARDWARE IS MOUNTED 30" MIN -44" MAX FROM FINISH FLOOR TO

TOP OF THE DEVICE.

LATCHING & LOCKING DOORS THAT ARE HAND OPERATED AND WHICH ARE IN A

PATH OF TRAVEL ARE OPERABLE WITH A SINGLE EFFORT (LEVER, PUSH/PULL, PANIC BAR OR OTHER

HARDWARE ASSIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE

OPENING HARDWARE)

MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBF, WHEN FIRE DOORS

ARE REQUIRED THE MAX EFFORT TO OPERATE THE DOOR MAY BE INCREASED TO THE MINIMUM

ALLOWABLE BY THE APPROPRIATE AUTHORITY , NOT TO

EXCEED 15 LBF.

1/4"

MAX

1/2"

MAX

NOTE: NEW BUILDING INTERIOR AND EXTERIOR THRESHOLDS WILL BE REQUIRED TO

BE NO HIGHER THAN 1/2" ABOVE THE ADJACENT FLOOR LEVELS. EACH EXPOSED EDGE OF

THRESHOLDS IS REQUIRED TO BE BEVELED OR SLOPED AT AN ANGLE NOT TO EXCEED 45 DEGREES SO

THAT NO VERTICAL CHANGE OF ELEVATION EXCEEDS

1/4" INCH.

" M

IN

B

O

TT

O

AI

L

GUARDR

AIL PROTECT SHADED

AREA FROM CROSS-

TRAFFIC

M

AX

80 "

POST OR

PYLON

4"

MAXAMOU

NT

AN

Y

POST OR

PYLON

12"

MAX

12"

MAX

CANE

RANGE

PLA

N

WALKING PARALLEL TO

WALL

WALKING PARALLEL TO

WALL

WALKING PERPENDICULAR

TO WALL

W H

EN

H

IG

ER

TH

AN

7"

M

IN

W H

EN

7" O

BE

LO

W27

M

AX

11"

MIN

30 DEG

MAX

11"

MIN

1 1/2"

MAX

1/2"

RADIUS

RADIU

S

RADIU

S

1"

MAX FROM

EDGE OF

TREAD

11"

MIN

1 1/2"

MAX

2" MIN STRIP

WIDTH

A. FLUSH

RISER

B. ANGLED

NOSING

C. ROUND

NOSING

D.

STRIPING

7"

AX7"

7"

.0

0°

12"

MIN

12"

MIN

12" + TREAD

WIDTH

TREA

D

A. EXTENSION AT BOTTOM OF RUNB. EXTENSION AT TOP

OF RUN

34 "

M

AX

34 "

M

AX

34 "

2 1/4"

MAX

2 1/4"

MIN

OD: 1 1/4" MIN, 2"

MAX PERIMETER

DIMENSION: 4" MIN, 6 1/4"

MAX

CLEARANCE

DIMENSION: 1 1/2"

MIN

1/

2"

2 1 /4"

MAX

4"

4"1/

1/4"

MAX.

STANDA

RDHEIGHT

FOUNTAIN

FACE OF

ALCOVE WAL

LSTANDARD HEIGHT

FOUNTAIN

48"

MIN

STANDARD

HEIGHT FOUNTA

INACCESSIBLE

FOUNTAIN

ACCESSIBLE

FOUNTAIN CLEAR

FLOOR SPAC

E

5"

MAX

18"

MIN

(X

18"

MIN ACCESSIB

LEFOUNTA

IN

A.

PLAN

B. SIDE

ELEVATION

NOT

E: IF ALCOVE DEPTH (X) IS GREATER THAN 24", THEN (Y) MUST BE

54" MIN ON AN ACCESSIBLE FOUNTAIN WITH A ROUND OR OVAL BOWL, THE

SPOUT MUST BE POSITIONED SO THE FLOW OF WATER IS WITHIN 3" OF THE FRONT

EDGE OF THE FOUNTA

IN

M

IN

M

IN

M

IN(Y )

M

IN

M

AX

R

EC

O M

M

EN

D E

M

AX

M

IN

18" MIN(X)

48"

MIN(Y

CANE DETECTION

SURFACE

15"

MIN5"

MAX

CLEAR

FLOOR SPAC

E

17 23/32"

MIN

A.

PLAN

30"

MIN

B. SIDE

ELEVATION

SIDE

BARS

C

LE

AR

12 "

M

IN

M

9"

M

IN

M

AX

Project

Building

Drawing

Project Title

Location

Issue DateCheckedDrawn

Drawing

Approve

VA FORM 08 -

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

2 14567891

Phase

PROJECT MANAGEMENTSTAMP CONSULTANT

3 2 14567891

FULLY

SPRINKLERED

4G

INTERIORS

Austin, Texas 78746

ARCHITECTURE

5121 Bee Caves Road, Suite 203

T:512 -327 -4149

COX DESIGN ASSOCIATES

PLANNING

F:512 -327 -7679

Austin bcox@coxdesignassociates.com09/10/2020

BIM

360://ALM

VAH

4G

C

AN

C

ER

C

EN

TER

/ALM

VAH

_4G

C

AN

C

ER

C

EN

TER

_C

D

_AR

C H

_08182020.rvt

9/10/2020 4:35:01 PM

GI-007

CONSTRUCTION

DOCUMENTS -100%

ACCESSIBILITY STANDARDSCONSTRUCT 4G CANCER

CENTER

7400 MERTON MINTER BLVD.

SAN ANTONIO, TX. 78229

09/10/2020RHCMAG

671-250

SCALE: NTS 12BOTTOM HANDRAIL EXTENSION AT STAIRS

SCALE: NTS 6DOOR HARDWARE

SCALE: NTS 7DOOR THRESHOLD

SCALE: NTS 9CANE DETECTION AREA

SCALE: NTS 8PROTRUDING OBJECTS

SCALE: NTS 11STAIR TREAD ACCEPTABLE NOSINGS & WARNING STRIPING

SCALE: NTS 13HANDRAIL EXTENSIONS

SCALE: NTS 10HANDRAIL PROFILES

SCALE: NTS 3BEVELED CHANGE IN LEVEL

SCALE: NTS 1VERTICAL CHANGE IN LEVEL

SCALE: NTS 5DRINKING FOUNTAIN -ALCOVE (HIGH-LOW)

SCALE: NTS 4DRINKING FOUNTAIN -NON-ALCOVE

OF

LAV

OF

LAV 18

28"

MIN TO

FIXTURE

REFLECTI

VEPOLYCARBON

ATE MIRRO

R

SAFETY

SOAP DISPENS

ER

CLEAR

FLOOR SPAC

E

30"

MIN

17"

MIN

8"

MIN

INSULA

TE EXPOSED

PIPES

A. PLANB. FRONT ELEVATIONC. SIDE ELEVATION

MA

X

M

IN19

M

AX

M

IN

M

AX34

M

AX

M

AX

29 "

9"

" M

C

LR

M

AX

M

AX

OF

FIXT

30"

CLEARTOILET

TISSUE DISPENS

ER

42"

GRAB BA

R

A. PLANB. FRONT ELEVATIONC. SIDE ELEVATION

54"

MIN

OF

FIXT

36"

MIN.

12"

MIN.

12"

MAX

"42" GRAB

BAR

7"-9 " 1' -

6"

TOILE

TTISSU

EDISPENS

ER, PER

PLANS

C L

OPERABLE

PART OF

ACCESSORY

6"

MAX

60" MIN TO EDGE OF

LAV

36"

GRAB BA

R

FROM WALL TO EDGE

OF LAV

C

LE

AR

M

AX

M

IN

M

TO

VA

LV

E 3'

-8

M

AX

TO

T

O P

O F

SE

AT 17

33 "

M

IN

M

AX

MA

X

60" M

IN DIA

CLEAR

8 "

MANUFACTU

RER

B Y

PULL

HANDLE

CLEAR ACRYLIC

WINDOW

FACE OF

WALL

180° DOOR

SWING

M

IN

M

AX

7-9

M

IN

60"

MIN.

1.

5"

15 "

A. PROJECTING OBJECTSB. RECESSED OBJECTS

AF

F

NOTE: PIPE DIMEN ARE SHOW AS

NOM DIA

TOP OF GRAB

BAR

4 -4.8" PERIMETER

1 1/4" 1 1/4"

MIN2"

MAX

NOTE:

2" MAX

ALLOWABLE

STRESSES SHALL

NOT BE

EXCEEDED FOR

MATERIALS USED

WHERE A

VERTICAL OR

HORIZONTAL

FORCE OF 250

LBS. IS APPLIED

AT ANY POINT ON

THE GRAB BAR,

FASTENER

MOUNTING

DEVICE OR

SUPPORTING

STRUCTURE.

PROVIDE 1 1/2"

MIN CLEAR

ACCESS AROUND

THE PERIMETER

OF THE GRAB BAR

2"

MAX

CODE CARD

FIRE ALARM STATION

DIGITAL

ALARM

SYSTEM

WALL

MOUNTED

COAT HOOK

DOOR

MOUNTED

COAT HOOKS

(4'-0" FO

R

AD

A

IN

STALLATIO

N S

CONTINUOUS FLOOR TO

CEILING CORNER

GUARD

MOP AND

BROOM

HOLDER

FIRE

EXTINGUISHER

CABINET

SWITCHES

FIRE

ALARM

PULL

ELECTRICAL &

TELEPHONE

RECEPTACLESTV / CABLE OUTLET

THERMOSTATS

MASTER

PAGE

INTERCOM

MASTER

STATION

DUTY STATION

STAFF STATION

FOR REFERENCE ONLY -THIS DOES NOT INDICATE EQUIPMENT OR FIXTURES PROVIDED

FINISH CEILING

FINISH FLOOR

4' -6"

4' -0"

1' -6"

1' -0"

5' -6"

3"

EXISTIN

G

M

ATC

H

M

AX

3' -6"

3' -10"

1' -0"

3' -6"

M

AX

4' -0"

1' -6"

9"

6"

9"

4' -6"

EQEQEQ

5' - 0"

ROOM SIGNAGE

SEE SHEET AS-721

ACCESS CONTROL HARDWARE

DOOR PUSH

PLATE, 4'-0" MIN.

AWAY FROM DOOR

STRIKE IF LOCATED

ON AN ADJACENT

WALL

2' - 10"

MIN.

1' - 3"

6' - 0"

1' -0"

Project

Building

Drawing

Project Title

Location

Issue DateCheckedDrawn

Drawing

Approve

VA FORM 08 -

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

2 14567891

Phase

PROJECT MANAGEMENTSTAMP CONSULTANT

3 2 14567891

FULLY

SPRINKLERED

4G

INTERIORS

Austin, Texas 78746

ARCHITECTURE

5121 Bee Caves Road, Suite 203

T:512 -327 -4149

COX DESIGN ASSOCIATES

PLANNING

F:512 -327 -7679

Austin bcox@coxdesignassociates.com09/10/2020

BIM

360://ALM

VAH

4G

C

AN

C

ER

C

EN

TER

/ALM

VAH

_4G

C

AN

C

ER

C

EN

TER

_C

D

_AR

C H

_08182020.rvt

9/10/2020 4:35:04 PM

GI-008

CONSTRUCTION

DOCUMENTS -100%

ACCESSIBILITY STANDARDSCONSTRUCT 4G CANCER

CENTER

7400 MERTON MINTER BLVD.

SAN ANTONIO, TX. 78229

09/10/2020RHCMAG

671-250

SCALE: NTS 2ACCESSIBLE LAVATORY

SCALE: NTS 1SINGLE-ACCOMODATION TOILET ROOM

SCALE: NTS 5FIRE EXTINGUISHER CABINET -PLAN

SCALE: NTS 4DISPENSER OUTLET LOCATION

SCALE: NTS 3SIZE OF CLEARANCE AT WATER CLOSETS

SCALE: NTS 6SPACING OF GRAB BARS

SCALE: NTS 7GRAB BAR NON-CIRCULAR CROSS SECTION

SCALE: 1/4" = 1'-0" 8STANDARD MOUNTING DETAILS

GI-010

WURZBACH ROAD

M

ER

TO

N

M

IN

TER

BABCOCK R

OAD

BABCOCK R

OAD

MELR

OSE H

OLM

GREEN R

OAD

MAIN PARKING LOT

POLYTRAUMA

REHIBILITATION CENTER

MAIN TOWER

"G" BUILDING

MAIN BUILDING

COMMUNITY LIVING

CENTER

SPINAL CORD

INJURY UNIT

ENTRANCE

CANTEEN

Project

Building

Drawing

Project Title

Location

Issue DateCheckedDrawn

Drawing

Approve

VA FORM 08 -

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

2 14567891

Phase

PROJECT MANAGEMENTSTAMP CONSULTANT

3 2 14567891

FULLY

SPRINKLERED

4G

INTERIORS

Austin, Texas 78746

ARCHITECTURE

5121 Bee Caves Road, Suite 203

T:512 -327 -4149

COX DESIGN ASSOCIATES

PLANNING

F:512 -327 -7679

Austin bcox@coxdesignassociates.com09/10/2020

BIM

360://ALM

VAH

4G

C

AN

C

ER

C

EN

TER

/ALM

VAH

_4G

C

AN

C

ER

C

EN

TER

_C

D

_AR

C H

_08182020.rvt

9/10/2020 4:35:06 PM

GI-009

CONSTRUCTION

DOCUMENTS -100%

SITE PLAN -OVERALL CAMPUS

SITE PLAN

CONSTRUCT 4G CANCER

CENTER

7400 MERTON MINTER BLVD.

SAN ANTONIO, TX. 78229

09/10/2020RHCMAG

671-250

SCALE: 1" = 100'-0" 1OVERALL SITE PLAN

N

4G CANCER CENTER

MAIN BUILDING

MAIN TOWER

MERTON MINTER

W

URZBACH RD.

SPINAL CORD

INJURY UNIT

CONTRACTOR

STAGING

AREACL

EA

R

24' - 0"

141' - 3 1/2" - 15 PARKING SPACES WIDE

PROPOSED

CRANE AREA

A

PROPOSED

CRANE AREA

B

CL

EA

R

25' - 0"

58' - 2 5/8"

LOCATION OF EXISTING

DUMPSTERS

VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING WORK, AND REPORT ANY

DISCREPANCIES IMMEDIATELY TO VA COR OR ARCHITECT FOR CLARIFICATION.

REFERENCE MECHANICAL, PLUMBING, ELECTRICAL, STRUCTURAL, DATA, GENERAL

INFORMATION DOCUMENTS FOR COORDINATION ITEMS.

CONTRACTOR TO PROVIDE AND MAINTAIN A SECURE FENCE AROUND STAGING AND

CRANE AREAS, PROVIDE LOCKING HARDWARE AT ALL GATES AND MAN GATES,

COORDINATE LOCATION OF GATES AND MAN GATES WITH VA COR. PROVIDE

REQUIRED SIGNAGE AND MESH AROUND STAGING AND CRANE AREAS, MAINTAIN

AREAS CLEAN AND FREE OF DEBRIS AND DUST. DUMPSTERS TO BE LOCATED IN

STAGING AREA, COORDINATE LOCATION OF STAGING AND CRANE AREAS WITH VA

COR. CONTRACTOR IS RESPONSIBLE FOR CLOSING AND LOCKING DUMPSTERS, IF

DUMPSTERS ARE LEFT OPEN, IT IS AT THE CONTRACTOR'S OWN RISK IF ITEMS ARE

THROWN INTO THE DUMPSTERS.

IF THE CONTRACTOR ELECTS TO HAVE A CONSTRUCTION TRAILER, IT SHALL BE

FURNISHED AND PROVIDED BY THE CONTRACTOR. ALL TEMPORARY SERVICE SHALL

BE PAID AND COORDINATED WITH THE LOCAL UTILITY PROVIDER BY THE

CONTRACTOR. CONSTRUCTION TRAILER WILL BE LOCATED IN THE VA PARKING LOT

OFF VON SCHEELE RD. COORDINATE WITH THE VA COR FOR THE EXACT LOCATION.

A.

B.

C.

D.

KEY PLAN

NOT TO SCALE

4G CANCER

CENTER

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue DateCheckedDrawn

Drawing Title

Approve

VA FORM 08 -

A

Office of Construction &

Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

2 14567891

Phase

PROJECT MANAGEMENTSTAMP CONSULTANT

3 2 14567891

FULLY SPRINKLERED

4G

INTERIORS

Austin, Texas 78746

ARCHITECTURE

5121 Bee Caves Road, Suite 203

T:512 -327 -4149

COX DESIGN ASSOCIATES

PLANNING

F:512 -327 -7679

Austin bcox@coxdesignassociates.com

GENERAL NOTES

09/10/2020

BIM

360://ALM

VAH

4G

C

AN

C

ER

C

EN

TER

/ALM

VAH

_4G

C

AN

C

ER

C

EN

TER

_C

D

_AR

C H

_08182020.rvt

9/10/2020 4:35:08 PM

GI-010

CONSTRUCTION

DOCUMENTS -100%

SITE PLAN -LIMITS OF

CONSTRUCTION

CONSTRUCT 4G CANCER

CENTER

7400 MERTON MINTER BLVD.

SAN ANTONIO, TX. 78229

09/10/2020RHCMAG

671-250

N

SCALE: 1" = 30'-0" 1LIMITS OF CONSTRUCTION

FD FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

UP

DN

UP

UP

FD

FD

FD

6.17

E

D

C

B

A

L1

L

K.1

7.188.199.11010.11111.0511.111.212

A.1

PROCEDURE

G420

EXAM/

CONSULT

ROOM

G424

EXAM/

CONSULT

ROOM

G423

CONFERENCE

ROOM

G422

TOILET

G420.1

TOILET

G411

TOILET

G412

STAFF

TOILET

G410

EXAM/

CONSULT

ROOM

G409

EXAM/

CONSULT

ROOM

G408

EXAM/

CONSULT

ROOM

G407

EXAM/

CONSULT

ROOM

G406

EXAM/

CONSULT

ROOM

G405

EXAM/

CONSULT

ROOM

G403

EXAM/

CONSULT

ROOM

G404

PROCEDURE

G402

TOILET

G402.1H.A.C.

G401

TOILET

G400

EXAM/

CONSULT

ROOM

G430

EXAM/

CONSULT

ROOM

G429

EXAM/

CONSULT

ROOM

G428

EXAM/

CONSULT

ROOM

G427

EXAM/

CONSULT

ROOM

G426

EXAM/

CONSULT

ROOM

G425

WOMEN'S

RESTROOM

F402

MEN'S

RESTROOM

F403

WAITING

F400

CORRIDOR

C403

H.A.C.

G413

ELEC.

G414

EXAM/

CONSULT

ROOM

G415

EXAM/

CONSULT

ROOM

G416

EXAM/

CONSULT

ROOM

G417

EXAM/

CONSULT

ROOM

G418

EXAM/

CONSULT

ROOM

G419

APHERESIS

H400

ADMINISTRATION

K400

ENCLOSED

BRIDGE

C400

ELEC.

E401

HEIGHT/

WEIGHT

G432

OFFICE

K403

OFFICE

K402

STAFF

WORK AREA

G421

RECEPTION

F404

CORRIDOR

C401

STAIR 11

4S11

CHECK-IN

KIOSK

F401

STAIR 10

4S10

STAIR 12

4S12

CORRIDOR

C404

CORRIDOR

C407

CORRIDOR

C406

CORRIDOR

C409 CORRIDOR

C405

A.2

FEC

FEC

FEC

FEC

FEC

FEC

FEC

FEC

FEC

FEC

STAFF

SUPPORT

G422.1

PHARMACY

WORK

ROOM

J402

PHARMACY

BREAK

ROOM

J401

NON-HAZARDOUS

BUFFER

ROOM

J406

HAZARDOUS

BUFFER

ROOM

J404

HAZARDOUS

STORAGE

J403

ANTE-ROOM

J405

CORRIDOR

C411

CORRIDOR

C402

DISTANCE TO SMOKE BARRIER = 185 FT

(200 FT MAX)

EXIT ACCESS TRAVEL DISTANCE = 116 FT

(200 FT MAX)

EXIT AC

C

ESS TR

AVEL D

ISTAN

C

E = 122 FT

(200 FT M

AX)

EXIT AC

C

ESS TR

AVEL D

ISTAN

C

E = 153 FT

(200 FT M

AX)

EXIT ACCESS TRAVEL DISTANCE = 127 FT

(200 FT MAX)

ELEVATOR

CONTROL

ROOM

E402

SECURE

TECHNOLOGY

E400

CORRIDOR

C401.1

SMOKE COMPARTMENT I

10,047 SF

SMOKE COMPARTMENT II

12,436 SF

SMOKE BARRIER WALL AT

ENCLOSED BRIDGE

CONNECTION TO 4G

SMOKE BARRIER WALL AT

ENCLOSED BRIDGE

CONNECTION TO EXISTING

BUILDING

FEC

FEC

KEY PLAN

NOT TO SCALE

4G CANCER

CENTER

N

LEGEND

A. BUILDING IS TO HAVE A FULLY AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE

WITH NFPA 101. RE. FIRE PROTECTION DRAWINGS FOR ADDITIONAL INFORMATION.

B. EXIT STAIR ENCLOSURES ARE TWO HOUR RATED FOR HEALTH CARE OCCUPANCY

(HC).

C. ALL PARTITIONS SHOWN WITHOUT FIRE RATING ARE NON-RATED U.N.O.

D. DURING DEMOLITION AND NEW CONSTRUCTION PHASES, CONTRACTOR SHALL

MAINTAIN REQUIRED RATING AT ALL EXISTING WALLS, FLOORS AND ROOFS TO REMAIN.

E. REFER TO SHEET 1-AS-620, TECHNOLOGY AND ELECTRICAL DRAWINGS FOR DOOR

SCHEDULE, NUMBER, HARDWARE, RATING AND SECURITY INFORMATION.

F. CONTRACTOR SHALL COORDINATE WITH ALL DISCIPLINE DRAWINGS FOR ADDITIONAL

INFORMATION.

G. ALL DOORS IN A RATED PARTITION OR SMOKE PARTITION SHALL HAVE THE

APPROPRIATE RATING TO CORRESPOND WITH WALL.

H. REFER TO SHEET 1-AS-530 FOR PARTITION TYPES.

I. UNLESS OTHERWISE NOTED, ALL AREAS ARE HEALTH CARE (HC) OCCUPANCY.

J. ALL PORTIONS OF HEALTH CARE (HC) OCCUPANCY TO THE NEAREST EXIT ARE

1 HOUR RATED FIRE

PARTITION

SMOKE PARTITION -

NON FIRE RATED

1 HOUR FIRE RATED

SMOKE BARRIER

2 HOUR RATED FIRE

PARTITION

FIRE EXTINGUISHER

CABINET -SEMI RECESSED FEC

NEW PARTITION

EXISTING PARTITION

PATH OF TRAVEL /

TRAVEL DISTANCE

85 FT

EXIT SIGN SINGLE…