Attachment 2 - Product data for Type 1 SPD.pdf

PDF 270 KB Posted

Attached to
J Percy Priest Trailer Utility Hookup Federal contract opportunity
Solicitation number
W912P522Q0012
Issued by
Department of the Army Corps of Engineers Engineering District Nashville

About this file

This document includes a federal solicitation for utility hookup services at a survey trailer located at J. Percy Priest Lake in Nashville, Tennessee. The solicitation was issued by the Department of the Army Corps of Engineers Engineering District Nashville under number W912P522Q0012. Site visits are scheduled for March 3, 2022, with forms due by February 25. The solicitation seeks utility hookup and surge protection products. Required surge protection products are specified in Attachment 2 and must meet ANSI/IEEE standards with a 15-year warranty. Panelboard specifications are provided in Attachment 3. Plans for the site are in Attachment 1. The wage determination is TN20220083.

View the file

Other files for this federal contract opportunity

Other files attached to J Percy Priest Trailer Utility Hookup, newest first.
File Type Posted
USACE site Visit Sign In.pdf PDF
W912P522Q0012_A0001.pdf PDF
Attachment 1- Plans 2021-3-14-22.pdf PDF
Survey Trailer_A0001_Summary.pdf PDF
Attachment 1- Plans 2021-11-17 2.0.pdf PDF
W912P522Q0012 Solicitation - J Percy Priest Survey Trailer Utility Hookup.pdf PDF
TN20220083.pdf PDF
Attachment 1- Plans 2021-11-17.pdf PDF
FN Pre_Bid or Site Visit Form JAN 2019.pdf PDF
Attachment 3- Product data for Panelboard.pdf PDF
US Citizen Pre_Bid or Site Visit Form JAN 2019.pdf PDF
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PRODUCT SPECIFICATIONS

kA Rating (Must Choose One)

060 60kA per mode 080 80kA per mode 100 100kA per mode 120 120kA per mode 150 150kA per mode 200 200kA per mode

Voltage (Must Choose One)

220-1G 220V, 1-Phase, 2-Wire + Ground 230-1G 230V, 1-Phase, 2-Wire + Ground 240-1G 240V, 1-Phase, 2-Wire + Ground 120/240-2G 120/240V, 2-Phase, 3-Wire + Ground 120/208-3GY 120/208V, 3-Phase Wye, 4-Wire + Ground 220/380-3GY 220/380V, 3-Phase Wye, 4-Wire + Ground 230/400-3GY 230/400V, 3-Phase Wye, 4-Wire + Ground 277/480-3GY 277/480V, 3-Phase Wye, 4-Wire + Ground 347/600-3GY 347/600V, 3-Phase Wye, 4-Wire + Ground 120/240-3GHD 120/240V, 3-Phase High-Leg Delta, 4-Wire + Ground (B-Phase must be 208V) 240-3DG 240V, 3-Phase Delta, 3-Wire + Ground 380-3DG 380V, 3-Phase Delta, 3-Wire + Ground 480-3DG 480V, 3-Phase Delta, 3-Wire + Ground 600-3DG 600V, 3-Phase Delta, 3-Wire + Ground

Available Options

S Stainless Steel Enclosure D For 200kAIC External Disconnect SD For External Disconnect & Stainless Steel Enclosure Leave blank for no Disconnect & Standard Enclosure

Stand-Alone Option (To Be Ordered As Separate Items) DTS DTS-2 Diagnostic Test Set

General Specifications Maximum Surge Current Rating 60kA per mode, 120kA per phase Nominal Discharge Surge Current I-n = 20kA Safety Listings UL Listed 1449 4th Edition for Type 1 and Type 2 SPD applications, cUL, and UL 1283 / Meets Requirements for UL 96A / Compliant to IEEE C62.41.1-2002, C62.41.2-2002 and C62.45-2002 / NFPA 70 [NEC], Article 285 / RoHS Compliant

Repetitive Surge Current Rating 3,500 impulses per mode based on actual test data (using ANSI/IEEE C62.41.1-2002 C3 combo wave)

Product Design Hybrid parallel design Individually fused MOVs UL 1283 EMI/RFI Filter

Application ANSI/IEEE C62.41.1 Locations C, B and A Ideal for Distribution Panels, Branch Panels and Critical Loads Standard Monitoring Status indicator lights (one per phase) Service indicator light Form C contacts (NO/NC) Audible alarm with silence button Surge counter Fault Current (SCCR) 200kAIC – no upstream over-current protection device (breaker or fuse) required Connection Method Parallel Protection Modes All Modes (L-N, L-G, N-G, L-L) Response Time < 0.5 Nanoseconds Operating Frequency 47 – 63 Hz Warranty 15 Year

EMI / RFI Filter Attenuation – Mil Standard 220B Up to 40 dB from 10 KHz to 100 MHz

C G P — 06 0 — 1 2 0 / 2 0 8 - 3 G Y — S

M od el kA R at in g

Vo lta ge

Op tio n

E.g.: CGP-060-120/208-3GY (as shown in above photo)

MODEL NUMBER SCHEME

60 CurrentGuardTM

PlusCGP S U R G E P R O T E C T I O N

SYSTEM FEATURES

Extra Features

• UL Listed 1449 4th Edition for Type 1 and Type 2 SPD applications.

• Innovative Z-Path SystemTM ensures equal current sharing, increased reliability and maximum performance

• Individually fused MOVs provide superior protection and continuous operation

• 200kAIC short circuit current rating allows direct bus connection without the need for an upstream over-current protection device

• Includes best-in-class UL 1283 enhanced EMI/RFI filter

• All modes of protection (L-N, L-G, N-G & L-L)

• Form “C” contacts and audible alarm with silence button – standard

• Surge event counter – standard

• DTS-2 compatible for proactive testing

• Ultra compact steel NEMA 4 enclosure makes installation flexible

• 15-Year standard product warranty

CURRENTGUARD PLUS 60 PERFORMANCE DATA

System Voltage 220V 230V 240V

120/240V 120/208V

220/380V 230/400V 277/480V

347/600V 120/240V 240V 380V 480V 600V

Protection Mode L-N L-G N-G L-N L-G L-L N-G L-N L-G L-L N-G L-N L-G L-L N-G L-N H-N L-G H-G L-L H-L N-G L-G L-L L-G L-L L-G L-L

MCOV 320 320 320 150 150 300 150 320 320 640 320 420 420 840 420 150 320 150 320 300 470 150 320 320 550 550 750 750

B3 Ring Wave 6kV, 500A

640 759 721 405 470 605 322 640 759 960 721 715 829 1130 670 405 640 470 640 605 800 322 759 640 1050 860 1260 1070

B3/C1 Combo Wave 6kV, 3kA

1010 1022 957 590 644 980 603 1010 1022 1740 957 1250 1340 2300 1230 590 1010 644 1022 980 1400 603 982 1070 1500 1720 1960 2260

C3 Combo Wave 20kV, 10kA

1540 1600 1550 970 1160 1430 1100 1540 1600 2260 1550 1910 1960 2910 1880 970 1540 1160 1600 1430 2050 1100 1630 1550 2260 2340 2760 2950

UL1449 3rdEdition 6kV, 3000A

VPR

1000 1000 1000 700 700 1200 700 1000 1000 1800 1000 1500 1500 2500 1500 700 1000 700 1000 1000 1500 700 1000 1000 1800 1800 2500 2500

CGP60

-1

/24

0- 2G

CGP60

-1

/20

8- 3G

Y

CGP60

-2

/38

0- 3G

Y

CGP60

-2

-1

G

CGP60

-2

/40

0- 3G

Y

CGP60

-2

-1

G

CGP60

-2

/48

0- 3G

Y

CGP60

-2

-1

G

CGP60

-3

/60

0- 3G

Y

CGP60

-1

/24

0- 3G

HD

CGP60

-2

-3

GD

CGP60

-3

-3

GD

CGP60

-4

-3

GD

CGP60

-6

-3

GD

Model Number

Enclosure Type Powder coated, impact-resistant steel, weather-proof NEMA 4

Installation Location Indoor or outdoor

Dimensions 10"H x 8.75"W x 6.3"D

Connection Method Hard-wired via internal lugs #10AWG –

#3 AWG

Mounting Method Dual mounting flanges

Operating Environment -40° F to +158° F (-40° C to +70° C) 5% – 95% non-condensing humidity

Weight 30 lbs.

CGP60 Inches (mm) H1 10.00 (254.0) H2 10.75 (273.1) H3 11.50 (292.1) W1 8.75 (222.3) W2 6.75 (171.5) D 6.30 (160.0)

MECHANICAL SPECIFICATIONS

DIMENSIONAL SPECIFICATIONS

BRO-CGP060-MK-2031 C01 081418

ABB

Electrification Products Division Building Products

Current Technology Surge Protective Devices Tel: +1 800 238 5000 Fax: +1 804 236 4841 new.abb.com/low-voltage/products/surge

Specifications are subject to change without notice

All CurrentGuardTM systems measured limited voltages are peak values (±10%) measured from the zero reference point and are in compliance with test and evaluation procedures outlined in NEMA LS1-1992 (R2000), paragraphs 2.210 and 3.10.

File details come from the government source that posted it. Updated .