Attachment 2_Drawing.pdf

PDF 280 KB Posted

Attached to
Sprung Structure Repair Service Federal contract opportunity
Solicitation number
W912CN-22-Q-0013
Issued by
Department of the Army Materiel Command Army Contracting Command

View the file

Other files for this federal contract opportunity

Other files attached to Sprung Structure Repair Service, newest first.
File Type Posted
Attachment 2_Questions and Answers_v2..docx DOCX document
Attachment 1_Performance Work Statement Sprung Structure Repair Service_ v3.docx DOCX document
Attachment 1_Performance Work Statement Sprung Structure Repair Service_ v2.docx DOCX document
Attachment 6_Picture 4.jpg JPG image
Attachment 8_Picture 6.jpg JPG image
Attachment 10_Wage Determination No. 2015 5683.pdf PDF
Attachment 1_ Performance Work Statement Sprung Structure Repair Service.docx DOCX document
Attachment 4_Picture 2_.jpg JPG image
Attachment 9_ Reference Information Sheet.docx DOCX document
Attachment 7_Picture 5.jpg JPG image
Attachment 5_Picture 3_.jpg JPG image
Attachment 3_Picture 1.jpg JPG image
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GENERAL NOTES:

TOLL FREE: 1-800-528-9899

or (403) 601-2292 www.sprung.com

CLASSIC SERIES

innovation versatility reliability

DRAWING APPROVAL

AutoCAD SHX Text

AutoCAD SHX Text 434.0

AutoCAD SHX Text

ELEVATION

AutoCAD SHX Text 1/16"=1'-0"

AutoCAD SHX Text

ELECTRIC VENT C/W DAMPER, 4 PLACES

AutoCAD SHX Text

TAN MEMBRANE

AutoCAD SHX Text

WING PANEL

AutoCAD SHX Text 7'10w HOOD (4x3) C/W SINGLE PERSONNEL DOOR (3'0x7'0)

AutoCAD SHX Text

AutoCAD SHX Text 434.0

AutoCAD SHX Text

PLAN VIEW

AutoCAD SHX Text 1/16"=1'-0"

AutoCAD SHX Text

ELECTRIC VENT C/W DAMPER, 4 PLACES

AutoCAD SHX Text

LOUVERED OPENING

AutoCAD SHX Text INT. MOUNT ROLLING SERVICE DOOR (14'0x14'0)

AutoCAD SHX Text 10'w HOOD (4x3) C/W SINGLE PERSONNEL DOOR (3'0x7'0)

AutoCAD SHX Text

LOUVERED OPENING

AutoCAD SHX Text

LOUVERED OPENING

AutoCAD SHX Text

LOUVERED OPENING

AutoCAD SHX Text INT. MOUNT ROLLING SERVICE DOOR (14'0x14'0)

AutoCAD SHX Text 10'w HOOD (4x3) C/W SINGLE PERSONNEL DOOR (3'0x7'0)

AutoCAD SHX Text

AutoCAD SHX Text 434.0

AutoCAD SHX Text

SECTION 90'-0" INSULATED STRUCTURE

AutoCAD SHX Text 3/32"=1'-0"

AutoCAD SHX Text 26%%D

AutoCAD SHX Text 8''x12'' ALUM. I BEAM

AutoCAD SHX Text

AutoCAD SHX Text 434.0

AutoCAD SHX Text

SECTION 7'-10" HOOD

AutoCAD SHX Text 1/4"=1'-0"

AutoCAD SHX Text 4"x3" HOLLOW ALUM. BEAM

AutoCAD SHX Text

AutoCAD SHX Text 434.0

AutoCAD SHX Text

SECTION 9'-5" HOOD

AutoCAD SHX Text 1/4"=1'-0"

AutoCAD SHX Text 4"x3" HOLLOW ALUM. BEAM

AutoCAD SHX Text

ALUM. I BEAM

AutoCAD SHX Text

AutoCAD SHX Text 434.0

AutoCAD SHX Text 8"x12" INSUL. BEAM SECTION

AutoCAD SHX Text 3"=1'-0"

AutoCAD SHX Text

ARCHITECTURAL MEMBRANE

AutoCAD SHX Text

ALUM. MEMBRANE RETAINER

AutoCAD SHX Text

NEOPRENE SEAL TO MEMBRANE

AutoCAD SHX Text

*NEW FIBERGLASS INSULATION

AutoCAD SHX Text

INTERIOR MEMBRANE

AutoCAD SHX Text

*NEW ALUM. MEMBRANE RETAINER

AutoCAD SHX Text

AS NOTED

AutoCAD SHX Text x

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

1. ALL PERSONNEL DOORS C/W PANIC HARDWARE & HOODS. 2. STRUCTURE MEMBRANE MEETS: NFPA 701, CALIFORNIA STATE FIRE MARSHAL, ASTM E84, CAN/ULC-S-109 & CAN/ULC-S-102 SPECIFICATIONS. 3. THIS STRUCTURE IS DESIGNED TO SHED/RELEASE SNOW. THE PERIMETER OF THE STRUCTURE SHALL BE KEPT CLEAR. 4. WHEN DESIGNING A HEATING, VENTILATION OR AIR CONDITIONING SYSTEM FOR ANY TYPE OF BUILDING, IT IS IMPORTANT TO ENSURE THAT THIS SYSTEM INTAKES MORE AIR THAN IS BEING EXHAUSTED AT ANY GIVEN TIME. THIS PROCESS WILL RESULT IN A POSITIVE PRESSURE BEING MAINTAINED. CONVERSELY, IF NEGATIVE PRESSURE EXISTS WITHIN THE STRUCTURE, IT WILL BE DIFFICULT TO OPEN DOORS AND MOISTURE WILL BE DRAWN INTO THE STRUCTURE. 5. ALL INTERIOR WALLS & PARTITIONS (IF APPLICABLE) TO BE FREE STANDING & INDEPENDENT OF SPRUNG STRUCTURE.

AutoCAD SHX Text C

AutoCAD SHX Text SPRUNG INSTANT STRUCTURES INC. and must neither be used in

AutoCAD SHX Text manufacturing nor disclosed nor reproduced in whole or in part

AutoCAD SHX Text except with the prior written consent of SPRUNG INSTANT

AutoCAD SHX Text STRUCTURES INC. Any copying of this drawing in whole or in part

AutoCAD SHX Text and any use of it to construct the subject matter illustrated

AutoCAD SHX Text in it without prior written permission of SPRUNG INSTANT

AutoCAD SHX Text STRUCTURES INC. is prohibited.

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text INSTANT STRUCTURES INC. are the exclusive property of

AutoCAD SHX Text America, Canada and all other countries of the world. It, and

AutoCAD SHX Text all of the designs, technical data and engineering services

AutoCAD SHX Text represented by it and originated or rendered by SPRUNG

AutoCAD SHX Text This drawing is protected by copyright in the United States of

AutoCAD SHX Text C

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APP'D BY

AutoCAD SHX Text

DRAWING #

AutoCAD SHX Text

SCALE

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

CUST. APP'L

AutoCAD SHX Text

US MILITARY ALASKA

AutoCAD SHX Text 90.0

AutoCAD SHX Text 200.5

AutoCAD SHX Text

RESKIN

AutoCAD SHX Text P21-434.0

AutoCAD SHX Text

B. PHILIPOFF

AutoCAD SHX Text 10/05/2021

AutoCAD SHX Text

REV.

AutoCAD SHX Text

MM/DD/YY

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text Confirmation of wind speed at site per the local building dept.

AutoCAD SHX Text Initial

AutoCAD SHX Text MPH, Exposure

AutoCAD SHX Text Building Code:

AutoCAD SHX Text Date:

AutoCAD SHX Text Print Name

AutoCAD SHX Text Signature

AutoCAD SHX Text COLORS ON THESE ELEVATIONS MAY VARY SIGNIFICANTLY DEPENDING ON PRINTER OR MONITOR. PLEASE REFER TO MEMBRANE SAMPLES FOR ACTUAL COLORS.