Attachment 2_Drawing.pdf
PDF 280 KB Posted
- Attached to
- Sprung Structure Repair Service Federal contract opportunity
- Solicitation number
- W912CN-22-Q-0013
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 2_Questions and Answers_v2..docx | DOCX document | |
| Attachment 1_Performance Work Statement Sprung Structure Repair Service_ v3.docx | DOCX document | |
| Attachment 1_Performance Work Statement Sprung Structure Repair Service_ v2.docx | DOCX document | |
| Attachment 6_Picture 4.jpg | JPG image | |
| Attachment 8_Picture 6.jpg | JPG image | |
| Attachment 10_Wage Determination No. 2015 5683.pdf | ||
| Attachment 1_ Performance Work Statement Sprung Structure Repair Service.docx | DOCX document | |
| Attachment 4_Picture 2_.jpg | JPG image | |
| Attachment 9_ Reference Information Sheet.docx | DOCX document | |
| Attachment 7_Picture 5.jpg | JPG image | |
| Attachment 5_Picture 3_.jpg | JPG image | |
| Attachment 3_Picture 1.jpg | JPG image |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL NOTES:
TOLL FREE: 1-800-528-9899
or (403) 601-2292 www.sprung.com
CLASSIC SERIES
innovation versatility reliability
DRAWING APPROVAL
AutoCAD SHX Text
AutoCAD SHX Text 434.0
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text 1/16"=1'-0"
AutoCAD SHX Text
ELECTRIC VENT C/W DAMPER, 4 PLACES
AutoCAD SHX Text
TAN MEMBRANE
AutoCAD SHX Text
WING PANEL
AutoCAD SHX Text 7'10w HOOD (4x3) C/W SINGLE PERSONNEL DOOR (3'0x7'0)
AutoCAD SHX Text
AutoCAD SHX Text 434.0
AutoCAD SHX Text
PLAN VIEW
AutoCAD SHX Text 1/16"=1'-0"
AutoCAD SHX Text
ELECTRIC VENT C/W DAMPER, 4 PLACES
AutoCAD SHX Text
LOUVERED OPENING
AutoCAD SHX Text INT. MOUNT ROLLING SERVICE DOOR (14'0x14'0)
AutoCAD SHX Text 10'w HOOD (4x3) C/W SINGLE PERSONNEL DOOR (3'0x7'0)
AutoCAD SHX Text
LOUVERED OPENING
AutoCAD SHX Text
LOUVERED OPENING
AutoCAD SHX Text
LOUVERED OPENING
AutoCAD SHX Text INT. MOUNT ROLLING SERVICE DOOR (14'0x14'0)
AutoCAD SHX Text 10'w HOOD (4x3) C/W SINGLE PERSONNEL DOOR (3'0x7'0)
AutoCAD SHX Text
AutoCAD SHX Text 434.0
AutoCAD SHX Text
SECTION 90'-0" INSULATED STRUCTURE
AutoCAD SHX Text 3/32"=1'-0"
AutoCAD SHX Text 26%%D
AutoCAD SHX Text 8''x12'' ALUM. I BEAM
AutoCAD SHX Text
AutoCAD SHX Text 434.0
AutoCAD SHX Text
SECTION 7'-10" HOOD
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text 4"x3" HOLLOW ALUM. BEAM
AutoCAD SHX Text
AutoCAD SHX Text 434.0
AutoCAD SHX Text
SECTION 9'-5" HOOD
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text 4"x3" HOLLOW ALUM. BEAM
AutoCAD SHX Text
ALUM. I BEAM
AutoCAD SHX Text
AutoCAD SHX Text 434.0
AutoCAD SHX Text 8"x12" INSUL. BEAM SECTION
AutoCAD SHX Text 3"=1'-0"
AutoCAD SHX Text
ARCHITECTURAL MEMBRANE
AutoCAD SHX Text
ALUM. MEMBRANE RETAINER
AutoCAD SHX Text
NEOPRENE SEAL TO MEMBRANE
AutoCAD SHX Text
*NEW FIBERGLASS INSULATION
AutoCAD SHX Text
INTERIOR MEMBRANE
AutoCAD SHX Text
*NEW ALUM. MEMBRANE RETAINER
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text x
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1. ALL PERSONNEL DOORS C/W PANIC HARDWARE & HOODS. 2. STRUCTURE MEMBRANE MEETS: NFPA 701, CALIFORNIA STATE FIRE MARSHAL, ASTM E84, CAN/ULC-S-109 & CAN/ULC-S-102 SPECIFICATIONS. 3. THIS STRUCTURE IS DESIGNED TO SHED/RELEASE SNOW. THE PERIMETER OF THE STRUCTURE SHALL BE KEPT CLEAR. 4. WHEN DESIGNING A HEATING, VENTILATION OR AIR CONDITIONING SYSTEM FOR ANY TYPE OF BUILDING, IT IS IMPORTANT TO ENSURE THAT THIS SYSTEM INTAKES MORE AIR THAN IS BEING EXHAUSTED AT ANY GIVEN TIME. THIS PROCESS WILL RESULT IN A POSITIVE PRESSURE BEING MAINTAINED. CONVERSELY, IF NEGATIVE PRESSURE EXISTS WITHIN THE STRUCTURE, IT WILL BE DIFFICULT TO OPEN DOORS AND MOISTURE WILL BE DRAWN INTO THE STRUCTURE. 5. ALL INTERIOR WALLS & PARTITIONS (IF APPLICABLE) TO BE FREE STANDING & INDEPENDENT OF SPRUNG STRUCTURE.
AutoCAD SHX Text C
AutoCAD SHX Text SPRUNG INSTANT STRUCTURES INC. and must neither be used in
AutoCAD SHX Text manufacturing nor disclosed nor reproduced in whole or in part
AutoCAD SHX Text except with the prior written consent of SPRUNG INSTANT
AutoCAD SHX Text STRUCTURES INC. Any copying of this drawing in whole or in part
AutoCAD SHX Text and any use of it to construct the subject matter illustrated
AutoCAD SHX Text in it without prior written permission of SPRUNG INSTANT
AutoCAD SHX Text STRUCTURES INC. is prohibited.
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text INSTANT STRUCTURES INC. are the exclusive property of
AutoCAD SHX Text America, Canada and all other countries of the world. It, and
AutoCAD SHX Text all of the designs, technical data and engineering services
AutoCAD SHX Text represented by it and originated or rendered by SPRUNG
AutoCAD SHX Text This drawing is protected by copyright in the United States of
AutoCAD SHX Text C
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APP'D BY
AutoCAD SHX Text
DRAWING #
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
CUST. APP'L
AutoCAD SHX Text
US MILITARY ALASKA
AutoCAD SHX Text 90.0
AutoCAD SHX Text 200.5
AutoCAD SHX Text
RESKIN
AutoCAD SHX Text P21-434.0
AutoCAD SHX Text
B. PHILIPOFF
AutoCAD SHX Text 10/05/2021
AutoCAD SHX Text
REV.
AutoCAD SHX Text
MM/DD/YY
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text Confirmation of wind speed at site per the local building dept.
AutoCAD SHX Text Initial
AutoCAD SHX Text MPH, Exposure
AutoCAD SHX Text Building Code:
AutoCAD SHX Text Date:
AutoCAD SHX Text Print Name
AutoCAD SHX Text Signature
AutoCAD SHX Text COLORS ON THESE ELEVATIONS MAY VARY SIGNIFICANTLY DEPENDING ON PRINTER OR MONITOR. PLEASE REFER TO MEMBRANE SAMPLES FOR ACTUAL COLORS.