Attachment 1 - Technical Information for SD114121-02-PDF.pdf

PDF 155 KB Posted

Attached to
4110--Refrigeration Equipment Replacement Federal contract opportunity
Solicitation number
36C24424Q0667
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4

About this file

This document is a Request for Quote (RFQ) for the replacement of refrigerated equipment at the Philadelphia, PA VAMC. The solicitation number is 36C24424Q0667 and it is an SDVOSB set-aside with a NAICS code of 333415. The contractor is required to furnish all necessary labor, materials, equipment, and supervision to replace the refrigerated equipment, with installation and completion within 90 days of the awarded contract. The estimated period of performance is June 17, 2024, to August 30, 2024. The Service Contract Act applies, and contractors must comply with applicable SCA wage determination rates and fringe benefits. Quotes must be submitted via email to the Contracting Officer by 12:00 PM EST on June 5, 2024. The award will be based on Price and Other Factors as stated in the Statement of Work. The vendor must provide details on their refrigerator experience, certifications, and key personnel.

View the file

Other files for this federal contract opportunity

Other files attached to 4110--Refrigeration Equipment Replacement, newest first.
File Type Posted
VENDORS QUESTIONS AND ANSWERS B.pdf PDF
36C24424Q0667 0003_1.docx DOCX document
36C24424Q0667 Amendment 0003.pdf PDF
36C24424Q0667 Attachment 0002a.pdf PDF
VENDORS QUESTIONS AND ANSWERS ATTACHMENT.pdf PDF
36C24424Q0667 0002_1.docx DOCX document
36C24424Q0667 0001.pdf PDF
36C24424Q0667 Amendment 0001.pdf PDF
36C24424Q0667 0001_1.docx DOCX document
36C24424Q0667_1.docx DOCX document
WD 2015-4233 Rev. 28 26DEC2023.pdf PDF
36C24424Q0667.pdf PDF
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SUPPORT FOR UNIT COOLER

NTS

PREFAB.

CEILING

PANEL AS

SPECIFIED

UNIT COOLER

5/8" [16 MM] DIAMETER

NYLON THROUGH BOLT

WITH NUT AND WASHER

(TYP)

EXTENDED UNIT COOLER DRAIN TO

DISCHARGE INTO FLOOR DRAIN-(WRAP

DRAIN WITH ELECTRIC HEATER

ELEMENT FOR FREEZER SERVICE)

1/2" [15mm] HANGER ROD SECURED

TO STRUCTURE ABOVE (TYP)

TURNBUCKLE (TYP)

BOSS FOR HANGER ROD WELDED

TO CHANNEL. MAX. 4'-0"

[1200mm] CC SPACING (TYP)

3" [75mm] 5# U CHANNEL LOCATED

TO SUIT UNIT COOLER (TYP)

S P A C E R

M I N m m ] 3" [75mm] WASHER

SCALE :

CADD DETAIL NO. : DATE ISSUED :

DETAIL TITLE / SUPPORT FOR UNIT COOLER

SD114121-01.DWG DECEMBER 2008

NONE

NOTES FOR AIR COOLED REFRIGERATION SYSTEM

1. UNIT COOLER FAN(S) SHALL RUN CONTINUOUSLY, EXCEPT WHEN IT IS TURNED "OFF"

BY A SWITCH MOUNTED ON THE UNIT COOLER. THIS SAME SWITCH SHALL ALSO

DE-ENERGIZE THE LIQUID-LINE SOLENOID VALVE WHEN THE UNIT IS IN THE "OFF"

POSITION..

2. ROOM THERMOSTAT FOR WALK-IN REFRIGERATOR OR FREEZER SHALL AUTOMATICALLY

CONTROL THE LIQUID-LINE SOLENOID VALVE.

3. COMPRESSOR OPERATION SHALL BE CONTROLLED BY THE LOW PRESSURE SWITCH: HIGH

PRESSURE CUTOUT SWITCH SHALL PREVENT THE COMPRESSOR FROM OPERATING UNDER

EXCESSIVELY HIGH HEAD PRESSURE.

4. AIR COOLED CONDENSER SHALL BE INSTALLED WITH AN APPROVED METHOD OF

MAINTAINING SUFFICIENT CONDENSING PRESSURE TO ASSURE SATISFACTORY OPERATION

AT ____ DEGREES. F. [ ____ DEGREES. C] AMBIENT TEMPERATURE.

5. WHEN EQUIPMENT SCHEDULE INDICATES ELECTRIC DEFROST, THE FOLLOWING CONTROLS

SHALL ALSO BE PROVIDED:

A. DEFROST TYPE UNIT COOLER WITH HEATING ELEMENTS FOR EVAPORATOR COIL,

DRAIN PAN AND DRAIN PIPING WITHIN THE LOW TEMPERATURE ROOM. DEFROST

CYCLE SHALL BE AUTOMATICALLY CONTROLLED BY AN ELECTRIC CLOCK AND

SHALL INCLUDE A SAFETY THERMOSTAT IN THE CONTROL CIRCUIT TO PREVENT

OVERHEATING THE EVAPORATOR COIL.

B. THE AUTOMATIC TIMER FOR ELECTRIC DEFROST SHALL ALSO DE-ENERGIZE THE

SOLENOID VALVE IN THE LIQUID REFRIGERANT LINE SERVING THE UNIT COOLER

AND SHALL STOP THE UNIT COOLER FAN(S) DURING THE DEFROST CYCLE.

6. PROVIDE ADDITIONAL TEMPERATURE TRANSMITTER THAT SENDS HIGH TEMPERATURE

ALARM INDICATION TO ECC.

SCALE :

CADD DETAIL NO. : DATE ISSUED :

DETAIL TITLE / NOTES FOR AIR COOLED

REFRIGERATION SYSTEM

SD114121-02.DWGDECEMBER 2008

NONE

00 01 15-01
SD000115-02.pdf
00 01 15-02
SD000115-03.pdf
00 01 15-03
SD000115-04.pdf
00 01 15-04
SD000115-05.pdf
00 01 15-05
SD000115-06.pdf
00 01 15-06
SD000115-07.pdf
00 01 15-07
SD000115-08.pdf
00 01 15-08
SD000115-09.pdf
00 01 15-09
SD000115-11.pdf
00 01 15-11
SD000115-10.pdf
00 01 15-10
SD000115-12.pdf
00 01 15-12
SD000115-13.pdf
00 01 15-13
SD000115-14.pdf
00 01 15-14
SD000115-15.pdf
00 01 15-15
SD000115-16.pdf
00 01 15-16
SD000115-17.pdf
00 01 15-17
SD000115-18.pdf
00 01 15-18
SD000115-19.pdf
00 01 15-19
SD000115-20.pdf
00 01 15-20
SD000115-21.pdf
00 01 15-21
SD000115-22.pdf
00 01 15-22
SD000115-23.pdf
00 01 15-23
SD000115-24.pdf
00 01 15-24
SD000115-25.pdf
00 01 15-25
SD000115-26.pdf
00 01 15-26
SD001000-01.pdf
11x17
SD001000-02.pdf
11x17
SD001000-03.pdf
11x17
Div01GenRequirAll.pdf
11x17
SD010000-02.pdf
11x17
Div05MetalsAll.pdf
8.5x11
SD055000-01.pdf
8.5x11
SD055000-02.pdf
8.5x11
Div06WoodPlastCompAll.pdf
8.5x11
SD062000-02.pdf
11x17
Div07ThermMoistProtAll.pdf
8.5x11
Div08OpenAll.pdf
8.5x11
SD080000-02.pdf
8.5x11
SD081113-01.pdf
8.5x11
SD081113-02.pdf
Layout1
SD081113-03.pdf
8.5x11
SD081113-04.pdf
8x11
SD085659-01.pdf
8.5x11
Div10SpecialitiesAll.pdf
8.5x11
SD101400-02.pdf
8.5x11
SD101400-03.pdf
11x17
SD101400-04.pdf
11x17
SD101400-05.pdf
8.5x11
SD102113-01.pdf
11x17
SD102113-02.pdf
Layout1
SD102600-01.pdf
8.5x11
SD102800-01.pdf
Layout1
SD102800-02.pdf
11x17
SD102800-03.pdf
8.5x11
SD102800-04.pdf
11x17
Div11EquipAll.pdf
8.5x11
SD114121-01.pdf
8.5x11
SD114121-02.pdf
8.5x11
SD114121-03.pdf
8.5x11
SD115313-01.pdf
Layout1
SD115313-02.pdf
8.5x11
SD115353-01.pdf
8.5x11
SD115353-02.pdf
8.5x11
Div12FurnishAll.pdf
8.5x11
SD123100-02.pdf
11x17
SD123570_21-01.pdf
11x17
Div13SpecConstrAll.pdf
11x17
SD134900-02.pdf
8.5x11
SD134900-03.pdf
11x17
SD134900-04.pdf
11x17
SD134900-05.pdf
11x17
SD134900-06.pdf
11x17

File details come from the government source that posted it. Updated .