Attachment 1 - Technical Information for SD114121-02-PDF.pdf
PDF 155 KB Posted
- Attached to
- 4110--Refrigeration Equipment Replacement Federal contract opportunity
- Solicitation number
- 36C24424Q0667
About this file
This document is a Request for Quote (RFQ) for the replacement of refrigerated equipment at the Philadelphia, PA VAMC. The solicitation number is 36C24424Q0667 and it is an SDVOSB set-aside with a NAICS code of 333415. The contractor is required to furnish all necessary labor, materials, equipment, and supervision to replace the refrigerated equipment, with installation and completion within 90 days of the awarded contract. The estimated period of performance is June 17, 2024, to August 30, 2024. The Service Contract Act applies, and contractors must comply with applicable SCA wage determination rates and fringe benefits. Quotes must be submitted via email to the Contracting Officer by 12:00 PM EST on June 5, 2024. The award will be based on Price and Other Factors as stated in the Statement of Work. The vendor must provide details on their refrigerator experience, certifications, and key personnel.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| VENDORS QUESTIONS AND ANSWERS B.pdf | ||
| 36C24424Q0667 0003_1.docx | DOCX document | |
| 36C24424Q0667 Amendment 0003.pdf | ||
| 36C24424Q0667 Attachment 0002a.pdf | ||
| VENDORS QUESTIONS AND ANSWERS ATTACHMENT.pdf | ||
| 36C24424Q0667 0002_1.docx | DOCX document | |
| 36C24424Q0667 0001.pdf | ||
| 36C24424Q0667 Amendment 0001.pdf | ||
| 36C24424Q0667 0001_1.docx | DOCX document | |
| 36C24424Q0667_1.docx | DOCX document | |
| WD 2015-4233 Rev. 28 26DEC2023.pdf | ||
| 36C24424Q0667.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SUPPORT FOR UNIT COOLER
NTS
PREFAB.
CEILING
PANEL AS
SPECIFIED
UNIT COOLER
5/8" [16 MM] DIAMETER
NYLON THROUGH BOLT
WITH NUT AND WASHER
(TYP)
EXTENDED UNIT COOLER DRAIN TO
DISCHARGE INTO FLOOR DRAIN-(WRAP
DRAIN WITH ELECTRIC HEATER
ELEMENT FOR FREEZER SERVICE)
1/2" [15mm] HANGER ROD SECURED
TO STRUCTURE ABOVE (TYP)
TURNBUCKLE (TYP)
BOSS FOR HANGER ROD WELDED
TO CHANNEL. MAX. 4'-0"
[1200mm] CC SPACING (TYP)
3" [75mm] 5# U CHANNEL LOCATED
TO SUIT UNIT COOLER (TYP)
S P A C E R
M I N m m ] 3" [75mm] WASHER
SCALE :
CADD DETAIL NO. : DATE ISSUED :
DETAIL TITLE / SUPPORT FOR UNIT COOLER
SD114121-01.DWG DECEMBER 2008
NONE
NOTES FOR AIR COOLED REFRIGERATION SYSTEM
1. UNIT COOLER FAN(S) SHALL RUN CONTINUOUSLY, EXCEPT WHEN IT IS TURNED "OFF"
BY A SWITCH MOUNTED ON THE UNIT COOLER. THIS SAME SWITCH SHALL ALSO
DE-ENERGIZE THE LIQUID-LINE SOLENOID VALVE WHEN THE UNIT IS IN THE "OFF"
POSITION..
2. ROOM THERMOSTAT FOR WALK-IN REFRIGERATOR OR FREEZER SHALL AUTOMATICALLY
CONTROL THE LIQUID-LINE SOLENOID VALVE.
3. COMPRESSOR OPERATION SHALL BE CONTROLLED BY THE LOW PRESSURE SWITCH: HIGH
PRESSURE CUTOUT SWITCH SHALL PREVENT THE COMPRESSOR FROM OPERATING UNDER
EXCESSIVELY HIGH HEAD PRESSURE.
4. AIR COOLED CONDENSER SHALL BE INSTALLED WITH AN APPROVED METHOD OF
MAINTAINING SUFFICIENT CONDENSING PRESSURE TO ASSURE SATISFACTORY OPERATION
AT ____ DEGREES. F. [ ____ DEGREES. C] AMBIENT TEMPERATURE.
5. WHEN EQUIPMENT SCHEDULE INDICATES ELECTRIC DEFROST, THE FOLLOWING CONTROLS
SHALL ALSO BE PROVIDED:
A. DEFROST TYPE UNIT COOLER WITH HEATING ELEMENTS FOR EVAPORATOR COIL,
DRAIN PAN AND DRAIN PIPING WITHIN THE LOW TEMPERATURE ROOM. DEFROST
CYCLE SHALL BE AUTOMATICALLY CONTROLLED BY AN ELECTRIC CLOCK AND
SHALL INCLUDE A SAFETY THERMOSTAT IN THE CONTROL CIRCUIT TO PREVENT
OVERHEATING THE EVAPORATOR COIL.
B. THE AUTOMATIC TIMER FOR ELECTRIC DEFROST SHALL ALSO DE-ENERGIZE THE
SOLENOID VALVE IN THE LIQUID REFRIGERANT LINE SERVING THE UNIT COOLER
AND SHALL STOP THE UNIT COOLER FAN(S) DURING THE DEFROST CYCLE.
6. PROVIDE ADDITIONAL TEMPERATURE TRANSMITTER THAT SENDS HIGH TEMPERATURE
ALARM INDICATION TO ECC.
SCALE :
CADD DETAIL NO. : DATE ISSUED :
DETAIL TITLE / NOTES FOR AIR COOLED
REFRIGERATION SYSTEM
SD114121-02.DWGDECEMBER 2008
NONE
| 00 01 15-01 |
| SD000115-02.pdf |
| 00 01 15-02 |
| SD000115-03.pdf |
| 00 01 15-03 |
| SD000115-04.pdf |
| 00 01 15-04 |
| SD000115-05.pdf |
| 00 01 15-05 |
| SD000115-06.pdf |
| 00 01 15-06 |
| SD000115-07.pdf |
| 00 01 15-07 |
| SD000115-08.pdf |
| 00 01 15-08 |
| SD000115-09.pdf |
| 00 01 15-09 |
| SD000115-11.pdf |
| 00 01 15-11 |
| SD000115-10.pdf |
| 00 01 15-10 |
| SD000115-12.pdf |
| 00 01 15-12 |
| SD000115-13.pdf |
| 00 01 15-13 |
| SD000115-14.pdf |
| 00 01 15-14 |
| SD000115-15.pdf |
| 00 01 15-15 |
| SD000115-16.pdf |
| 00 01 15-16 |
| SD000115-17.pdf |
| 00 01 15-17 |
| SD000115-18.pdf |
| 00 01 15-18 |
| SD000115-19.pdf |
| 00 01 15-19 |
| SD000115-20.pdf |
| 00 01 15-20 |
| SD000115-21.pdf |
| 00 01 15-21 |
| SD000115-22.pdf |
| 00 01 15-22 |
| SD000115-23.pdf |
| 00 01 15-23 |
| SD000115-24.pdf |
| 00 01 15-24 |
| SD000115-25.pdf |
| 00 01 15-25 |
| SD000115-26.pdf |
| 00 01 15-26 |
| SD001000-01.pdf |
| 11x17 |
| SD001000-02.pdf |
| 11x17 |
| SD001000-03.pdf |
| 11x17 |
| Div01GenRequirAll.pdf |
| 11x17 |
| SD010000-02.pdf |
| 11x17 |
| Div05MetalsAll.pdf |
| 8.5x11 |
| SD055000-01.pdf |
| 8.5x11 |
| SD055000-02.pdf |
| 8.5x11 |
| Div06WoodPlastCompAll.pdf |
| 8.5x11 |
| SD062000-02.pdf |
| 11x17 |
| Div07ThermMoistProtAll.pdf |
| 8.5x11 |
| Div08OpenAll.pdf |
| 8.5x11 |
| SD080000-02.pdf |
| 8.5x11 |
| SD081113-01.pdf |
| 8.5x11 |
| SD081113-02.pdf |
| Layout1 |
| SD081113-03.pdf |
| 8.5x11 |
| SD081113-04.pdf |
| 8x11 |
| SD085659-01.pdf |
| 8.5x11 |
| Div10SpecialitiesAll.pdf |
| 8.5x11 |
| SD101400-02.pdf |
| 8.5x11 |
| SD101400-03.pdf |
| 11x17 |
| SD101400-04.pdf |
| 11x17 |
| SD101400-05.pdf |
| 8.5x11 |
| SD102113-01.pdf |
| 11x17 |
| SD102113-02.pdf |
| Layout1 |
| SD102600-01.pdf |
| 8.5x11 |
| SD102800-01.pdf |
| Layout1 |
| SD102800-02.pdf |
| 11x17 |
| SD102800-03.pdf |
| 8.5x11 |
| SD102800-04.pdf |
| 11x17 |
| Div11EquipAll.pdf |
| 8.5x11 |
| SD114121-01.pdf |
| 8.5x11 |
| SD114121-02.pdf |
| 8.5x11 |
| SD114121-03.pdf |
| 8.5x11 |
| SD115313-01.pdf |
| Layout1 |
| SD115313-02.pdf |
| 8.5x11 |
| SD115353-01.pdf |
| 8.5x11 |
| SD115353-02.pdf |
| 8.5x11 |
| Div12FurnishAll.pdf |
| 8.5x11 |
| SD123100-02.pdf |
| 11x17 |
| SD123570_21-01.pdf |
| 11x17 |
| Div13SpecConstrAll.pdf |
| 11x17 |
| SD134900-02.pdf |
| 8.5x11 |
| SD134900-03.pdf |
| 11x17 |
| SD134900-04.pdf |
| 11x17 |
| SD134900-05.pdf |
| 11x17 |
| SD134900-06.pdf |
| 11x17 |
File details come from the government source that posted it. Updated .