About this file

This document is a Salient Characteristics Sheet that is part of a Request for Quotation (RFQ) for two (2) aerator units to be used with existing vaporized hydrogen peroxide decontamination equipment at the USDA Agricultural Research Service's National Poultry Research Center in Athens, GA.

The Salient Characteristics Sheet specifies that the required aerator units must have wheels for transportation, use 120V power, operate automatically as part of the Steris VHP Victory SmartPhase decontamination cycle, and have interconnecting cable or equivalent technology to link with existing Steris VHP Victory biodecontamination units. The "Brand Name" item that will satisfy the Government's needs is the Steris VHP AR1200 Aerator, and any "equal" item must meet or exceed these salient characteristics. The related federal contract opportunity, Solicitation Number 12405B24Q0265, has a due date for quotes of 10:00 AM Eastern Time on July 3, 2024. The Government intends to award a Firm Fixed Price purchase order to the responsible offeror whose quote conforms to the specifications and is the most advantageous based on the Brand Name or Equal provision and price.

View the file

Other files for this federal contract opportunity

Other files attached to Aerator Units, Athens, GA, newest first.
File Type Posted
Attachment 2_Price Sheet.docx DOCX document
Combined Synopsis_12405B24Q0265 Clauses and Provisions.pdf PDF
Attachment 3_52.225-2 Buy American Certificate.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 1- Salient Characteristics Sheet

The ARS SEA US National Poultry Research Center (USNPRC) in Athens, GA has the need to procure two (2) aerator units to be used with existing vaporized hydrogen peroxide decontamination equipment for laboratory and animal room/building decontaminations. These decontaminations are necessary for research integrity and personnel safety after and between when experiments are conducted.

The Contractor shall provide two (2) aerator units with the salient characteristics listed below. The “Brand Name” item that will satisfy the Government's needs is model Steris VHP AR1200 Aerator.

The “equal” item, in accordance with the “Brand Name or Equal” provision of this solicitation must meet or exceed the following characteristics:

• The aerators must have wheels to facilitate transportation.

• The aerators must use 120V power.

• The aerators must have the technology to operate automatically as part of Steris VHP Victory SmartPhase decontamination cycle.

• The aerators must have an interconnecting cable or equivalent technology to link with existing Steris model