Attach_B_Drawings_PAVILION_AND_RECREATION_IMPROVEMENT.pdf

PDF 1 MB Posted

Attached to
PAO PAVILION AND RECREATION IMPROVEMENTS
Solicitation number
140R4021Q0076
Issued by

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FOR OFFICIAL USE ONLY

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL -

JULIAN CIBRIAN

JULIAN CIBRIAN

JARED POSEY

SCOTT WINTERTON, PE

DIVISION MANAGER

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

Managing

LAR M TA IOCE N

W intheWa estter C A D

S

YS

TE

M

A ut oC A D

4.

0s C A D

F

IL

EN

A M

E

C O

V

ER

S H

EE

T.

D W

G

LA

S T

S A V

ED

D A

TE

-0 5-

LA

S T

S A V

ED

B Y

JC

IB

R

IA

N

PA

O

P A V

IL

IO

N

A N

D R

EC

R

EA

TI

O

N

IM

PR

O

V

EM

EN

TS

0%

C O

N S

TR

U C

TI

O N

D O

C U

M

EN

TS

COVER SHEET

PAO (PROVO, UT)

66-418-60036

2021-3-10

G1

PROVO AREA OFFICE

PAVILION AND RECREATION IMPROVEMENTS

AutoCAD SHX Text United States Department of the Interior

AutoCAD SHX Text

PROVO AREA OFFICE

AutoCAD SHX Text 302 East Lakeview Parkway, Provo, Utah 84606 / (801) 379-1000 (Previous Address 302 East 1860 S)

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

Managing

LAR M TA IOCE N

W intheWa estter C A D

S

YS

TE

M

A ut oC A D

4.

0s C A D

F

IL

EN

A M

E

S

H A D

E S

TR

U C

TU

R E.

D W

G

LA

S T

S A V

ED

D A

TE

-0 4-

LA

S T

S A V

ED

B Y

JC

IB

R

IA

N

PA

O

P A V

IL

IO

N

A N

D R

EC

R

EA

TI

O

N

IM

PR

O

V

EM

EN

TS

0%

C O

N S

TR

U C

TI

O N

D O

C U

M

EN

TS

DEMOLITION PLAN

PAO (PROVO,UT)

66-418-60037

2020-04-30

G2

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL -

JULIAN CIBRIAN

JULIAN CIBRIAN

JARED POSEY

SCOTT WINTERTON, PE

JEREMY FOWLER, PE

DIVISION MANAGER

DIGGING CAUTION BOUNDARY LINE

NOTE CALLOUTS

0 5' 10'

SITE PLAN

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

DEMOLITION NOTES

1 Remove and dispose of Railroad ties.

2 Remove Volleyball Net Post and concrete footings.

3 Remove volleyball court sand as required to meet slab on grade base course depth.

4 Concrete sidewalk joint.

5 Demolish concrete slab/sidewalk.

6 Concrete curb and/or sidewalk to remain.

7 Existing Electrical Conduit, See specification section 01 56 15 - Protection of Existing Utilities

8 Move landscape rock back and stockpile for future reinstallation within 6-feet of railroad ties up to volley ball net post. See Detail A4/60039 for more information.

LEGEND

DEMOLITION LINE

DEMOLISH AREA HATCH

GENERAL NOTES

1. All demolished items shall be removed from the site and properly recycled or disposed of according to local requirements and contract specifications, unless noted otherwise per specification section 02 41 00 - Demolition.

2. Contractor shall demolish and remove all items necessary to properly grade and prepare the site for construction improvements per specification sections 31 22 00 Grading and 31 23 00 - Excavation and Backfill. This includes items such as tree limbs, vegetation, debris, concrete, landscape rock, etc.

LIMITS OF WORK

RE

V

NO

1 1

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

Managing

LAR M TA IOCE N

W intheWa estter C A D

S

YS

TE

M

A ut oC A D

4.

0s C A D

F

IL

EN

A M

E

S

H A D

E S

TR

U C

TU

R E.

D W

G

LA

S T

S A V

ED

D A

TE

-0 4-

LA

S T

S A V

ED

B Y

JC

IB

R

IA

N

PA

O

P A V

IL

IO

N

A N

D R

EC

R

EA

TI

O

N

IM

PR

O

V

EM

EN

TS

0%

C O

N S

TR

U C

TI

O N

D O

C U

M

EN

TS

INSTALLATION PLAN

PAO (PROVO,UT)

66-418-60038

2020-04-30

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL -

JULIAN CIBRIAN

JULIAN CIBRIAN

JARED POSEY

SCOTT WINTERTON

JEREMY FOWLER

DIVISION MANAGERLEGEND

0 5' 10'

SITE PLAN

LIMITS OF WORK

RE

V

NO

20'-0"

30'-0"36'-0"

37'-0"

63'-3 3/8"

37'-0"

NEW CONSTRUCTION

1 Place pavilion footings per manufactured engineered drawings.

2 See sheet 60040 for electrical requirements

3 Place 6" reinforced slab-on-grade concrete pad per specification section 03 30 00 - Cast-In-Place Concrete. Match existing adjacent concrete elevations.

4 Repair concrete sidewalk per specification section 03 30 00 - Cast-In-Place Concrete.

5 Install gutter drain catch basin and 3" PVC drainage pipe to daylight.

6 Install government furnished adjustable basketball goal per manufacturers installation specifications.

7 Paint basketball court striping per NCAA dimensions.

8 Slope grade to 3:1 off edge of concrete until matching existing grade out within 6-feet per detail A4/60039.

NEW CONSTRUCTION LINE

EXISTING

NOTE CALLOUTS1

A2 60039

8'-6"

GENERAL NOTES

1. Install sub-base per Specification Section 32 11 00 Base Course

2. Protect existing trees and vegetation

3'-0"

A4 60039

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

Managing

LAR M TA IOCE N

W intheWa estter C A D

S

YS

TE

M

A ut oC A D

4.

0s C A D

F

IL

EN

A M

E

S

H A D

E S

TR

U C

TU

R E.

D W

G

LA

S T

S A V

ED

D A

TE

-0 4-

LA

S T

S A V

ED

B Y

JC

IB

R

IA

N

PA

O

P A V

IL

IO

N

A N

D R

EC

R

EA

TI

O

N

IM

PR

O

V

EM

EN

TS

0%

C O

N S

TR

U C

TI

O N

D O

C U

M

EN

TS

ELEVATIONS AND

DETAILS

PAO (PROVO,UT)

66-418-60039

2020-04-30

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL -

JULIAN CIBRIAN

JULIAN CIBRIAN

JARED POSEY

SCOTT WINTERTON

JEREMY FOWLER

DIVISION MANAGER

SITE PLAN

RE

V

NO

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

GENERAL NOTES

1. PAVILION DESIGN ABOVE IS THE MINIMUM REQUIREMENTS. CONTRACTOR SHALL

SUBMIT ENGINEERED DRAWINGS FROM PAVILION MANUFACTURE WITH

STRUCTURAL DETAILS AND CALCULATIONS.

2. DESIGN TO INCLUDE ELECTRICAL CUTOUTS IN TWO COLUMNS.

3. DESIGN TO INCLUDE RAIN GUTTERS ON TWO SIDES WITH DOWNSPOUTS.

4. CONTRACTOR SHALL INSTALL 12" THICK EXPANSION JOINTS WHERE NEW CONCRETE

MEETS EXISTING CONCRETE.

24'-0"

34'-0"

7'-6" Min. Clearance

13'-5" Reference

20'-0" OC

6"

12'-0"

8'-6"

30'-0" OC

6"

6"

A1 EAST ELEVATION

NTS A2 SECTION VIEW

NTS

A3 PLAN VIEW

NTS

3'-0"

A4 Slab-on-Grade Edge Detail

NTS

8'-6"

Slope grade to 3:1 until matching existing grade up to 6-feet

Reinstall river cobble rock over new 8 oz geotextile fabric

New Slab-on-Grade

S D

4492.59 345

4492.68

E E E E E E E E E

E E

E E

E E

E E

E

ELECTRICAL ROOM

EE

E E

E

L1D1

J s J

EE

J

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

Managing

LAR M TA IOCE N

W intheWa estter C A D

S

YS

TE

M

A ut oC A D

4.

0s C A D

F

IL

EN

A M

E

S

H A D

E S

TR

U C

TU

R E.

D W

G

LA

S T

S A V

ED

D A

TE

-0 4-

LA

S T

S A V

ED

B Y

JC

IB

R

IA

N

PA

O

P A V

IL

IO

N

A N

D R

EC

R

EA

TI

O

N

IM

PR

O

V

EM

EN

TS

0%

C O

N S

TR

U C

TI

O N

D O

C U

M

EN

TS

ELECTRICAL

PAO (PROVO,UT)

66-418-60040

2020-04-30

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL -

JULIAN CIBRIAN

JULIAN CIBRIAN

JARED POSEY

SCOTT WINTERTON

JEREMY FOWLER

DIVISION MANAGER

SITE PLAN

RE

V

NO

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

70'-3 3/4"

59'-1 1/2"

GENERAL NOTES

1 Install electrical per specification sections 26 05 10 - Conductors and Cables, 26

05 20 - Grounding and Bonding, 26 05 33 - Electrical Conduit, 26 27 30 - Wiring Devices, and 26 56 00 - Exterior Lighting.

ELECTRICAL NOTES

1 Install two 1-inch conduits from pavilion column cutouts under ground to southwest corner of building into a pull/junction box.

2 Wall mount conduit from junction box to above warehouse bay doors along solar power conduits back to electrical room. Contractor shall field verify measurements and conduit path.

3 Concrete core drilling required in multiple locations.

4 Terminate conductors in Electrical Sub-Panel L1D1 to 50 amp breakers 39 & 41.

5 Install (10) LED surface mounted exterior lighting fixtures with daylight sensors and 60-minute timer switch.

6 Install junction box

7 Install weatherproof light switch

8 Install duplex GFCI receptacle in weatherproof box.

1 1 2 3

7 6

30'-0"

60036 COVER SHEET
Sheets and Views
60036 COVER SHEET
60037 Site Demo
Sheets and Views
60037 Site Demo
60038 New Site Plan
Sheets and Views
60038 New Site Plan
60039 Details
Sheets and Views
60039 Details
60040 Electrical
Sheets and Views
60040 Electrical

File details come from the government source that posted it. Updated .