Attach-8-QTRS-3-Lead Paint Findings.pdf
PDF 2 MB Posted
- Attached to
- INKS DAM NFH REMODEL RESIDENCES #2 & Federal contract opportunity
- Solicitation number
- 140F0220R0043
About this file
This document summarizes the results of a lead-based paint inspection and risk assessment conducted at a U.S. Fish and Wildlife Service property. The inspection identified lead-based paint on exterior wood surfaces of the carport and on the exterior of the left-side gable that were rated in unsatisfactory condition. Interior paint was rated in good condition. Dust and soil samples showed levels below federal standards. The report recommends trained professionals repair the exterior lead-based paint and estimates costs of $400 to repair the carport and $375 for the gable. The associated federal contract opportunity is to remodel residences 2 and 3 at Inks Dam National Fish Hatchery, solicited by the Department of the Interior Fish and Wildlife Service Region 2. No further details are provided on response dates, award dates, pricing terms, or set asides.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140F0220R0043_Amd_0001.pdf | ||
| Attach-3-Specifications-Residence-2.pdf | ||
| Attach-7-QTRs-2-Lead Paint Findings.pdf | ||
| Attach-9-DBA Min. Wage Rates.pdf | ||
| Attach-5-Price Sheet.xlsx | XLSX spreadsheet | |
| Attach-2-Drawings Residence-3.pdf | ||
| Attach-4-Specifications-Residenc-3.pdf | ||
| Attach-1-Drawings-Residence-2.pdf | ||
| Sol_140F0220R0043.pdf | ||
| Attach-6-Past Performance and Clauses.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
·S2 . I e, mc.
10408 City Lights Dr., NE Albuquerque, NM 87111
Lead-Based Paint Inspection And Risk Assessment Report
For The Dwelling Located at:
Inks Dam National Fish Hatchery Quarters 73
Route 2 Burnet, TX 78611
(512) 793 2474
Prepared For:
Mr. Terry Clayton, POC No. 1448-98690-00-P022
U.S. Fish and Wildlife Service Division of Engineering
7333 W. Jefferson Ave., 8te. 375 Lakewood, CO 80235
(303) 984 6870; (303) 969 5444 fax
Prepared By:
P7:~ Robert T. Knowles, esp, Risk Assessor smfd: 002500050003 phone: (505) 823 6411 fax: (505) 828 0607
US EPA, Region 6 (TASCA 402), Certification No. NM-01-022003-049 XRF license No. WA-0653-D-106-8
And independent Special Safety evaluations, inc.-a Lead Firm US EPA Certification No. NMF 003
11 September 2000 independent Special Safety evaluations, inc. page: 1 of 17
Table of Contents
.002500050003 September 11, 2000
~~~ ~e
Part I: Executive Summary-------------------~------------------------------------------------------------- 3
Part II: Lead-Based Paint Standards and Definitions -------------------------------------------------- 5
Part III: Lead-Based Paint Inspection via XRF ----------------------------------------------------------- 8
Part IV: Lead-Based Paint Inspection ------------------------------------------------------------------ 12 A. Lead-Based Paint Components------------------------------------------------------------- 12 B. Lead Containing Components--------------------------------------------------------------- 12 C. Non-Lead-Containing Components -------------------------------------------------------- 13 D. P ai nt Rati n gs ------------------------------------------------------------------------------------ 13
Part V: Lead Glazes in Ceramic Tiles -------------------------------------------------------------------- 14
Part VI: Lead-Based Paint Risk Assessment--------------------------------------------------------- 15 A. Visual I nspection/Findings ------------------------------------------------------------------- 15 B. Background/Use Information ---------------------------------------------------------------- 15 C. Lead-Based Paint Hazard(s) ---------------------------------------------------------------- 15 D. Lead Dust Hazard( s) -------------------------------------------------------------------------- 15 E. Lead Contaminated Soil Hazard(s) -------------------------------------------------------- 16 F. Lead Water Testing ("1
Draw") ------------------------------------------------------------ 16
G. Other Lead Hazard(s) ------------------------------------------------------------------------- 16
Part VII: Prioritized List of Lead Hazards Identified ------------------------------------------------ 17 A. Recommended Solutions for Lead Hazards identified -------------------------------- 17 B. Estimated Costs to Repair Lead Hazards identified ----------------------------------- 17
Part VIII: Appendices Listing ---------------------------------------------------------------------------------- 18 A. Reports for Quarters 73, Inks Dam NFH ------------------------------------------------- 18
1) RAW XRF Data Report----------------------------------------------- 18 through 20
2) Preliminary XRF Report ---------------------------------------------- 21 through 23
3) Daily Calibration Report(s) ---------------~----------------------------------------- 24
4) HUD Single Family Housing Report------------------------------- 25 through 27
B. Assaigai Analytical Laboratories Dust & Soil Report-------------------- 28 through 29 C. Assaigai Analytical Laboratories Water Report ----------------------------------------- 30 D. Sketch of Property ----------------------------------------------------------------------------- 31 E. Photography of Property------------------------------------------------------- 32 through 34 independent Special Safety evaluations, inc. page: 2 of 17
Part I: Executive Summary
September 11, 2000 iS2e, inc. conducted a Lead-Based Paint (LBP) Inspection (PI) and LBP Risk Assessment (RA) at Quarters No. 73, Inks Dam National Fish Hatchery, Burnet, TX 78611 on August 30, 2000.
The home was occupied at the time of this inspection.
Quarters No.73 is a single story, pitched-roofed, frame and brick, single-family home with 3 bedrooms. The home faces to the east. Original construction occurred in 1961, comprising approximately 1182 ft2. The home presently houses a single, adult, female, full-time NFH employee.
Lead-based paint Inspection results:
The exterior white paint on the carport's wood surfaces (soffit, roof trim) is in "unsatisfactory" condition and in need of repair/repainting. The exterior white paint on the Left-side Gable and its associated soffit/roof trim is also in "unsatisfactory" condition, and also should be repaired/repainted. All five items contain LBP. Only trained and licensed professionals should repair all five items.
All of the interior paint in this home is rated to be in "good" condition. The amount of lead and concentrations in the interior of this home is indicative of 1950s or early 1960s interior paint.
Lead-based paint Risk Assessment results:
A. Recommended Solutions for Lead Hazards Identified:
1. Exterior Lead Paint Hazard #1 :
8. The exterior white paint on the soffit and roof trim of the carport was rated to be in "unsatisfactory" condition, and contains more than 10ft2 of LBP. Only trained and licensed professionals should repair this paint.
b. The exterior white paint on the gable, soffit and roof trim on the south side of this home was also rated to be in "unsatisfactory" condition, and comprised more than 10fe of LBP. Trained and licensed professionals should also only repair this paint.
B. Estimated Costs to Repair Lead Hazards Identified:
1. Exterior Lead Paint Hazard #1 :
8. Cost estimate to repair/repaint the Carport soffit and roof trim is $400.00.
(Approximately 128 ft2)
b. Cost estimate to repair/repaint the south gable, soffit and roof trim is $375.
(Approximately 123 fe) independent Special Safety evaluations, inc. page: 3 of 17
September 11, 2000
The U.S. Fish and Wildlife Service is currently developing formal policy and guidance on training for managers, employees and residents. The training will include general lead awareness, work practice requirements, OSHA lead in construction standards, and U.S. Fish and Wildlife Service policy requirements concerning lead.
For any activity that would disturb surfaces identified as having lead, notify Terry Clayton with the Environmental and Facility Compliance Office at (303) 984-6867 or Bernie Freeman, the Regional Compliance Officer, at (505) 984-7956 prior to beginning work. Any construction activities that affect the preceding paint films (including sanding and demolition) must be initiated by workers wearing respiratory protection, and who have received proper training in the handling of lead contaminated materials.
independent Special Safety evaluations, inc. page: 4 of 17
Part II:
September 11, 2000
Lead-Based Paint Definitions and Standards
A. Definitions:
1. Lead-Based Paint Inspection-defines and reports on the exact location of any/all painted surfaces that contain LBP by the HUD/EPA Interim Standard*.
*Note The term "Standard" is used interchangeably with "Interim Standard". All of the HUD Guidelines Standards and EPA's Work Practice Standards are, in fact, Interim Standards, meaning that they may be subject to regulatory change with new data that supports a change to the "Standard". HUD's 1012 and 1013 Regulation alters the exterior damaged paint "Standard" from 10fe to 20ft2
EPA's TASCA 403 Regulation, when published in final form, will alter the 400PPM soil "Standard" (limit) to an "Area of Concern" (vice a limit). "Standards" can also be "action levels", and in many cases are "action levels".
2. Lead-Based Paint Risk Assessment-A Risk Assessment is an onsite investigation of a residential dwelling for Lead-Based Paint (LBP) "hazards", that includes, but may not be limited to, a visual inspection, limited environmental samplings (assays) of deteriorated paint**, soil and dust. The assays may be accomplished via XRF or laboratory analysis of paint chip samples, or a combination of both. The Risk Assessment will include a detailed report that identifies potential LBP "hazards"; controls (repair/replacement) associated with those "hazards", and provide monitoring recommendations when appropriate. In particular, the Risk Assessment is designed to identify LBP "hazards" that include:
• Deteriorated LBP (chipped, flaking, cracking, chalking, etc.),
• LBP contaminated dust, soil and
• LBP involving accessible (to children), friction (rubbing), or impact
(slamming) surfaces that may have already, or may, in the future, damage a lead painted surface.
During the Risk Assessment, if any painted surfaces are noted to be damaged, then those surfaces are tested for lead content. Dust assays are taken at "key" locations that follow airflow patterns within the home in order to determine if lead is, or has migrated into or within the home.
independent Special Safety evaluations, inc. page: 5 of 17
3. Lead-Based Paint Ratings-iS2e, inc. uses a four scale paint rating system as follows:
• Good-Paint that is "new" or still has much of its "life" remaining. This rating requires no action by homeowner.
• Fair-Paint that is within 6-12 months of failure based on your iS2e, inc.
Risk Assessor's estimate. Paint requires little more than cleaning the surface prior to repainting. Homeowner may save considerable expense by applying another stabilizing coat of paint during the next 6-12 months.
• Poor-Paint that is "cracked or damaged such that its water tight integrity is compromised. Paint and/or substrate may require some repair prior to repainting.
• Unsatisfactory (Unsat)-Paint that is peeling such that the substrate beneath the paint is visible. Paint and/or substrate will usually require some repair prior to repainting. Homeowner may expect some wood component replacement due to "dry-rot", or metal component repair due to "rust".
B. Standards:
1. HUD/EPA's Lead-Based Paint Standard-defines LBP as ~1.0 mg/cm2 (or 0.5% by weight).
2. Lead-Based Paint Hazard-is, by HUO/EPA Standard:
• ~2ft2, interior LBP rated "poor" or "unsat" by your iS2e, inc. Risk
Assessor.
• ~10ft2, exterior LBP rated "poor" or "unsat" by your iS2e, inc. Risk
Assessor.
(Note: HUO's 1012/1013 Regulation will increase the affected area to 20fe effective 15 September 2000.)
3. Lead-Based Paint Dust Hazard-is, by HUO/EPA Standard, ("swipe") dust assay values determined by laboratory testing:
• Floors (hard surfaced and carpetedp-100 Ilg/ft2 (Note: carpeted floors will probably be changed to an "area of concern", vice a limit, with EPA's TASCA 403 Regulation, when finalized.)
• Interior window sill~500 Ilg/ft2
• Window troughs (or wells) ~800 Ilg/fe
4. Lead Contaminated Bare Soil Hazard-is, by HUO/EPA Standard:
• Bare Soi1---2400 ppm, for concentrated children's play areas (e.g. fenced back yards, schoolyards, playgrounds, ball fields, etc.) and vegetable gardens, requiring interim controls or abatement.
(Note: this limit will probably be changed to an "area of concern", vice a limit, with EPA's TASCA 403 Regulation, when finalized.)
• Bare Soi1---22000 ppm, for all other residential bare soils, requiring interim controls or abatement.
• Bare Soi1---25000 ppm, requires abatement.
independent Special Safety evaluations, inc. page: 6 of 17
5. OSHA Standard-is any level of airborne lead. The "action level" is 30 j.Jg (micrograms) per M3 (meter of air cubed) over an 8 hour, time-weighted-average (twa). This level will drive personnel protective equipment (PPE), such as respirators, coveralls, shower facilities, etc. The OSHA PEL (permissible elevation level) is 50 j.Jg/M3 (twa). This level will add medical monitoring, increased respirator capability, etc. OSHA is concerned with airborne lead and its effect upon the renovation/abatement worker. When LBP surfaces will be disturbed during renovation, especially in small interior spaces (closets, small bathrooms, etc.), the contractor should have the space monitored with a testing device that will alarm when the "action level" is triggered.
OSHA has identified several activities (e.g. manual demolition, manual scraping, manual/power sanding, heat gun applications, general cleanup, power tool cleaning with dust collection systems, and spray painting) that pose varying levels of potential lead exposure to workers disturbing lead-containing paint.
Estimated exposure levels of lead are founded in the activity itself, rather than the concentrations of lead present in the paint. For example, paints that contain 0.5% versus 15% of lead by weight or 0.8 mg/cm 2 versus 3.5 mg/cm2 of lead in paint could present the same levels of potential exposure to workers.
In other words, while HUD/EPA define LBP as paint containing lead at concentrations ~1.0 mg/cm2
, the OSHA Standard for airborne lead dust anticipates that as little as 0.1 or 0.2 mg/cm2 of lead in paint could present a hazardous condition when disturbed, causing exposure for workers. Because of this, iS2e, inc. provides the owner with a table (Part IV, A) showing all of the components that contain LBP by the HUD/EPA Standard; and a table (Part IV, B) showin~ all of the components that contain any lead between 0.1 and 0.9 mg/cm.
independent Special Safety evaluations, inc. page: 7 of 17
Part III: Lead-Based Paint Inspection by XRF
September 11, 2000
The EDAX (dba SCITEC), Inc., MAP 4 Spectrum Analyzer (XRF serial number M4-1375) used for this survey irradiates the paint on a given surface causing the lead in the paint, if present, to emit a characteristic frequency of X-ray radiation. The instrument identifies and counts these x rays to determine a lead concentration, and reports this concentration in mg/cm2
The XRF's (X-ray Fluorescence) source used to excite the lead is a 12-millicurie Cobalt57 gamma radiation pellet housed and shielded within the instrument. This particular XRF underwent its annual resource and re-calibration by the factory in Kennewick, WA in October 1999.
The XRF provides readings of "K-shell" (high energy) and "L-shell (low energy) lead. The K shell is the value that determines the amount of lead in the paint. The L-shell gives the operator information on the depth of the lead painted surface.
Your iS2e Risk Assessor uses either the "Confirm" or the "Unlimited" Modes of XRF operation during any Paint Inspections (PI) or Risk Assessments (RA). These modes are the most accurate and time consuming of the four modes (Screen, Test, Confirm, and Unlimited) within the instrument. The operator holds the trigger when sampling using the Unlimited Mode, until he/she gains approximate 2cr (sigma) worth of data on any given surface. This provides approximately 95% accuracy. The instrument is calibrated 5 times and averaged prior to leaving the office, calibrated at the job site, and re-calibrated approximately every hour thereafter, including job completion.
As can be seen from the Daily Calibration Log, an appendix to this report, M4-1375 remains within 0.10 mg/cm2 of the required 1.39mg/cm2 factory calibration block.
The SCITEC Ma~ 4 XRF has an "inconclusive" software" signal built into the instrument from
0.9 to 1.2 mg/cm. Values below this amount are, by HUD/EPA Standard, not lead-based paint (LBP). Values above this range are clearly LBP. The operator can take a paint chip sample for laboratory analysis in order to prove the accuracy of the reading when the reading is in this "inconclusive range", or make a conservative determination that the "inclusive" value contains
LBP.
Because the XRF has a capabilit¥ (calibration accuracy) of ±0.1 mg/cm2 when operating in the Confirm and Unlimited modes, is e, inc. has chosen to consider all readings (values) equal to or above 0.9 mg/cm2 to contain LBP. This corporate decision is based on 5 years of RA and PI experience. This determination saves the homeowner the laboratory analysis cost of multiple paint-chip samples, and does not adversely mark or harm any painted surface on the property (e.g. banister, windowsill, baseboard, door or window trim, etc.), often requiring expensive/time consuming repair.
When reading the XRF Preliminary Report, an addendum to this report, all negative K and L shell values should be interpreted as "zero". All K-shell XRF values above 0.1, but less than
0.9 mg/cm2 contain some lead, but the lead content is below the HUD/EPA standard defining LBP. All values at or above 0.9 mg/cm2 are considered, by iS2e, inc., to be LBP.
independent Special Safety evaluations, inc. page: 8 of 17
The SCITEC Map 4 XRF has, built into the software, substrate correction values that prevent the operator from having to make the corrections manually. The "Unlimited" mode of operation will correct properly, even if the operator makes an incorrect coding error (e.g. setting sheetrock when the substrate is actually plaster, etc.).
The 12-millicurie Cobalt57 gamma radiation pellet is so weak, even when first delivered from the factory, that it will not cause ionizing radiation to any surface or component tested. In other words, once the XRF is removed from the home, there is no lingering radiation, or any evidence that the XRF has ever been there.
Reading the Reports contained in the Appendices
1. Raw XRF Data:
Includes the coded address for the site, calibration data (both daily, and site beginning and ending), as well as assay data that has been collected at the home, apartment or day-care center.
2. Preliminary XRF:
Gives K & L-Shell XRF readings in mg/cm2
. The federal "action-level", always taken against the K-shell, is 1.0 mg/cm2
• The XRF has an "inconclusive" range of -0.1 to +0.2 centered about the "action-level". Should this "inconclusive" value occur, your Risk Assessor could remove a small (approx. 2x2 inch) sample of the painted surface for laboratory analysis, or declare the component to contain LBP. Declaring a component that contains 0.90 mg/cm 2 to contain LBP is a conservative and cost effective method of evaluating LBP.
Room # refers to the number of "like" rooms (e.g. 3 bedrooms). Wall # is conventional, where wall #1 is the wall toward the street (front or address side of the dwelling), and the other walls are numbered clockwise. Wall #3 is away from the street. Type refers to the mode of analysis that the SCITEC MAP 4 is operating under (e.g. screen, test, confirm, and unlimited). iS2e, inc. uses the confirm and unlimited modes exclusively, carrying the analysis to 20' (95% confidence level) in accordance with EPA and HUD standards.
Numerous interior, wooden, concrete, tile, and sheetrock/piaster dwelling components are checked. These include, but are not limited to, exterior walls, wood trim, window trim and frames, door trim, frames and jambs, roof trim and soffit, interior walls, hard surface flooring, including tile floors, baseboard, tub and shower surrounds, counter tops and back splashes, cabinets, windowsills, doors, and door jambs, etc.
3. Daily Calibration:
Includes the Daily start calibrations (normally 5) with times, and includes the site "start" and "stop" calibrations, as well as any others taken against a known "assay block" provided to iS2e, inc. by the SCITEC Corporation. The MAP 4 must always remain within ±0.1 of the factory test calibration for that specific serial numbered MAP. It will also typically remain within ±0.1 of the five Daily averages (column 6).
XRF MAP IV, serial number M4-1375 has had an exceptional record for accuracy. It almost always calibrates at or very near the 1.39 mg/cm2 certified SCITEC assay block, even early in the workday and increases its accuracy as the device warms.
independent Special Safety evaluations, inc. page: 9 of 17
This XRF device was resourced and delivered by FEDEX from the SCITEC factory in Kennewick, WA, 1000, 10-19-99.
4. HUD Single Family Housing Report:
This report is included for Paint Inspections (PI) because the HUD Guidelines requires that Pis test interior and exterior walls four times (all four walls within each room group or equivalent). Additionally, this report contains current surface paint color, where the Preliminary XRF Report does not.
5. Assaigai Laboratory Report:
Dust-The report gives "swipe" assay results in ~g/ft2. The dust assay values give the iS2e Risk Assessor a valid method for determining whether any lead-based paint has deteriorated to a level that may have already, or will in the future, contribute to the contamination of the dwelling, and whether that dust, if contaminated, has migrated within the dwelling.
Bare Soil-The report gives soil sample values in PPM (parts per million or I1g/g).
Dripline soil is that soil within 3-4 feet of the foundation of the home or apartment. It is often contaminated to a greater extent than yard soil, especially for older dwellings that contain significant exterior LBP. Yard soil is normally selected from areas that have evidence of the presence of children, or from vegetable gardens.
6. Lead-Based Paint-The "do's" and 'don'ts" of LBP repair:
When painted dwelling components contain LBP above the federal "action-levels";
DO NOT allow repairs to include:
a) Dry scraping or sanding, including machines without proper vacuum collection capability
b) Unconfined hydra-blasting
c) Open-flame burning or torching
d) Abrasive blasting or sand blasting without using HEP.A vacuum exhaust tools
e) Heat-guns that operate above 11 OO°F
f) HUD does not recommend using methylene chloride chemical strippers
When painted areas contain LBP above the federal "action-levels"; DO require repairs to include:
a) Use of HEPA filtering equipment attached to the sanding machines
b) Use of HEPA filtering vacuums to clean-up the area that has been scraped or sanded
c) Containment of the affected areas (e.g. no high winds)
d) If doors (exterior or interior) are removed to repair jambs, then seal off the residence of affected area using plastic sheeting and tape. (e.g. if repairing
e) a jamb on an exterior door leading to the kitchen, hang plastic sheeting with a "full-seal" tape on the inside of the door to prevent the LBP dust from migrating into the kitchen.)
f) Disposal of any contaminants and contaminated components using proper disposal methods.
independent Special Safety evaluations, inc. page: 10 of 17
7. Non-Professional Repair of LBP Components:
September 11, 2000
It is not often legal to repair, abate, or apply interim controls to LBP "hazards" or painted components that contain LBP to rental dwellings, or homes that house members not of your immediate family, unless you are trained to do so. However, it is permissible to make repairs when following (exactly) the written instructions of a certified LBP Risk Assessor. Those items that you can accomplish personally, involve:
• planting sod or placing other ground covering such as rock, over bare soil,
• painting surfaces that have been prepared professionally, or
• removing components that will not disturb LBP, such as doors, and then having them disposed of properly if they contain LBP.
8. Risk Assessments versus Paint Inspections:
Please remember a Risk Assessment does not test or identify all painted surfaces.
It only identifies those painted surfaces that were unsound (rated "poor" or "unsat" by your is2e Risk Assessor) unless specifically noted otherwise in the reports. A Paint Inspection, however, tests all "like" painted surfaces. "Like" painted surfaces are those that your iS2e Risk Assessor or Paint Inspector estimates to have the same or similar paint history, and clearly contain pre-1978 paint.
9. Title X's Disclosure Requirements:
A copy of this report must be provided to new lessees (tenants), providing the lease exceeds 100 days, and to purchasers of this property under Federal law (24 CFR part 35 and 40 CFR· part 745) before they become obligated under a lease or sales contract. The complete report must also be provided to new purchasers and it must be made available to new tenants.
Landlords (lessors) and sellers are also required to distribute an educational pamphlet approved by the U.S. Environmental Protection Agency and include standard warning language in their leases or sales contracts to ensure that parents have the information they need to protect their children from lead-based paint hazards.
Any repairs specified by this report, or accomplished on any of the leaded (Pb) surfaces identified in this report (See Table in Part IV, Sub-part A) should be documented on this report, attaching receipts to the report, maintaining dates, and any notes directly on the report. This report should be preserved and maintained with this dwelling. It will serve present and future homeowners with proper lead (Pb) disclosure as required by Title X, Section 1018 of Public Law 102-550.
10. Contacting your iS2e Risk Assessor:
If owner or agent has any questions concerning the findings or ramifications of this report, please call your iS2e Risk Assessor at 823 6411 (Albuquerque), or 1 888 8280607 outside of Albuquerque.
independent Special Safety evaluations, inc. page: 11 of 17
Part IV: Lead-Based Paint Inspection Results
A. Lead-based Paint (LBP) Components-Those items that contain lead at or above 0.9 mg/cm2
Preliminary XRF Report
No.
Component Location Color Paint HUD/EPA OSHA Lead XRF I
Conditio Lead Status Potential Result , n (;>1.0I1!g/cm21 (;>0.1 mg/cm2
) mglcm2 , I
Soffit Carport White Unsat LBP Yes 1.415 I
Roof Trim Carport White Unsat LBP Yes 1.655 Ext. Door Jamb Gar. Storage White Fair LBP Yes 1.455 Int. Front Door Gar. Storage White Good LBP Yes 0.933 I Soffit Exterior Front White Good LBP Yes 1.127 Gable Ext. Left Side White Unsat LBP Yes 0.927 Front Door Jamb Entry White Good LBP Yes 1.447 '
The components discovered during the onsite testing that exceeded the federal standard for lead paint are the items listed above.
The Leaded components are addressed in detail under Part V and VI, C of this Report.
B. Lead-Containing Components-Those items that contain lead at or above
0.1 mg/cm2
, but below 0.9 mg/cm2
Preliminary XRF Report No.
528,530 534,35,36 537,39,40
Component Location Color Paint HUD/EPA OSHA Lead XRF Cond Lead Status Potential Result ition J~1.0m-.-9lcm1 1>0.1 mg/cm2
) mglcm2
Entry Door Ext. Gar. Storage White Fair Non-LBP Yes 0.618 Roof Trim Ext. Front White Good Non-LBP Yes 0.284 Ceilino Front Porch White Fair Non-LBP Yes 0.775 Int. Wall- LHS Livino Room White Good Non-LBP Yes 0.109 Int. Wall- Rear Living Room White Good Non-LBP Yes 0.102 Int. Wall- RHS Living Room White Good Non-LBP Yes 0.113 Ceil ina Living Room White Good Non-LBP Yes 0.276 Int. Wall Average Hallway White Good Non-LBP Yes 0.103 Cabinets Hallway White Good Non-LBP Yes 0.238 Int. Wall- RHS Full Bath Tan Good Non-LBP Yes 0.155 Int. Wall- RHS Bedroom #1 White Good Non-LBP Yes 0.252 Ceilino Bedroom #1 White Good Non-LBP Yes 0.153 Int. Wall Averaoe Bedroom #2 White Good Non-LBP Yes 0.111 Int. Wall Averaoe Bedroom #3 White Good Non-LBP Yes 0.183 Int. Wall Averaoe Utilitv Room White Good Non-LBP Yes 0.157 Cabinets Kitchen White Good Non-LBP Yes 0.234 -
The HUD Guidelines require that painted interior walls of each room must be tested during a paint inspection. The requirement is driven by the fact that the interior walls generally contain the greatest painted areas within the home, and the fact that the lead content of the paint seldom is applied/distributed evenly.
independent Special Safety evaluations, inc. page: 12 of 17
The exterior white paint on the carport's wood surfaces (soffit, roof trim) is in "unsatisfactory" condition and in need of repair/repainting. The exterior white paint on the Left-side Gable and its associated soffit/roof trim is also in "unsatisfactory" condition, and also should be repaired/repainted. All five items contain LBP. Only trained and licensed professionals should repair all five items.
All of the interior paint in this home is rated to be in "good" condition. The amount of lead and concentrations in the interior of this home is indicative of 1950s or early 1960s interior paint.
C. Non-lead-Containing Components--Those items that contain lead below 0.1 mg/cm2
, or contain a negative K-shell reading.
All other components checked by XRF, throughout the property, and not listed in either of the two tables above, contained no detectable (or insignificant) lead content.
D. Paint Ratings-while regulations do not allow paint condition ratings by a paint inspector; the regulations do allow such rating during a paint inspection when performed by a risk assessor. This is done to assist the renovation contractor by alerting him/her to those painted surfaces that may require attention.
• Paints rated "Good" that contain lead present no current hazard unless disturbed.
• Paints rated "Fair" are nearing the end of their useful life and should be re stabilized with another coat of paint before they can become a source of lead dust.
• Paints rated "Poor" (cracked) or "Unsatisfactory" (peeling) should be removed, the surfaces/substrates repaired/replaced and then re-painted. The lead paint removal process should involve capturing all of the leaded paint, not allowing it to contaminate soil or any interior surfaces.
independent Special Safety evaluations, inc. page: 13 of 17
Part V: Lead-Glazes in Ceramic Tiles
·002500050003 September 11, 2000
NOT A LEAD HAZARD-The ceramic tiles on the Full Bath backsplash and the Utility Room floor contain low or insignificant quantities of lead in their glazes. (The reader's attention is invited to see lines 520, and 541, column #9 of the Preliminary XRF Report).
The interim federal standard, identifying lead-based paint, contains 1.0 mg/cm2 of lead. The backsplash ceramic tiles contain lead at 0.079 mg/cm2
However, it is your iS2e Risk Assessor's opinion, in consultation with the Region VI EPA toxic waste coordinator, Mr. Jeff Robinson, that these tiles currently do not present any LBP "hazard".
During renovation, if these tiles are removed/replaced (broken-up), they can create a significant amount of lead dust. Precautions should be taken during any such evolution to protect the workers, the inhabitants, and the dwelling itself. During any future renovation (when Pb painted surfaces, including the ceramic tiles, may be disturbed), Pb levels, even very low ones, can exceed OSHA respiratory Permissive Elevation (breathing) Levels (PELs), especially in confined spaces (e.g. closets, small bathrooms, etc.).
Ceramic tile has a baked-on glaze that is sufficiently durable to capture and hold any Lead Paint/glazing, so long as the glaze remains intact. The homeowner may limit his/her liability by making this report available to any contractor that attempts to remove this tile. This will alert the contractor to follow the OSHA regulations with regard to PELs. Additionally, the contractor should take ample precautions to prevent the spreading of any Pb dust during the tile removal throughout the home. These precautions should include:
• Sealing the affected rooms, using plastic sheeting and masking tape;
• Removing the tiles;
• Gathering the tiles into plastic bag-lined cardboard boxes (where the bag can be closed prior to removal from the area); and
• Using HEPA filtered vacuums (going over all exposed surfaces in the affected areas, including ceilings, walls, floors, windows, frames, sills, door trim, baseboards, etc.), twice covering with the vacuum all areas of the affected rooms, prior to .!:llsealing those rooms.
In order to repair any chipped or damaged tiles in the future, these should first by washed with warm, soapy water, rinsed and dried. The homeowner using epoxy-resin-paint may then repair the damaged portion of the tile. This will re-seal the lead within the glaze.
These leaded tiles should only be cleaned with pH neutral or basic solutions (soaps, aqueous bleach, or common cleaners - e.g. 409, etc.) Acid solutions, even mild ones, may eventually attack the glaze in these tiles, and therefore should not be used. Even vinegar and water, if used enough times, may break down the glaze protecting the lead in these tiles, and therefore, should not be used.
WARNING
DO NOT MIX AMMONIA AND BLEACH.
This combination will form a deadly gas!
independent Special Safety evaluations, inc. page: 14 of 17
Part VI:
September 11, 2000
Lead-Based Paint Risk Assessment
A. Visual Inspection/Findings:
iS2e, inc. conducted a Lead-Based Paint (LBP) Inspection (PI) and LBP Risk Assessment (RA) at Quarters No. 73, Inks Dam National Fish Hatchery, Burnet, TX 78611 on August 30, 2000. The home was occupied at the time of this inspection.
Quarters NO.73 is a single story, pitched-roofed, frame and brick, single-family home with 3 bedrooms. The home faces to the east. Original construction occurred in 1961, comprising approximately 1182 ft2. The home presently houses a single, adult, female, full-time NFH employee.
Floor dust samples were gathered from the front entry and back entry to this home.
Windowsill dust samples were gathered from Dining Room (S), Bedroom #1 (N) and Bedroom #2 (W).
A composite soil sample was gathered from various points, near the foundation, beneath windows, and annotated on the sketch at the end of this report. The bare soil, composite yard samples concentrated on play areas on the north and west sides of this home.
The results of the dust and soil testing are discussed in Sections D and E of this Part.
B. Background/Use Information: The home functions presently as a permanent residence for a single, adult, female full-time NFH employee.
C. Lead-Based Paint Hazard(s) Identified: Two (2)
1. The exterior white paint on the soffit and roof trim of the carport was rated to be in "unsatisfactory" condition, and contains more than 1 ate of LBP. Only trained and licensed professionals should repair this paint.
2. The exterior white paint on the gable, soffit and roof trim on the south side of this home was also rated to be in "unsatisfactory" condition, and comprised more than 10ft2 of LBP. Trained and licensed professionals should also only repair this paint.
D. Lead Dust Hazard(s) Identified: NONE (0)
The Assaigai Analytical Laboratories single floor dust assay values for:
• The front entry ....................................... 5.0 Ilglfe
• The rear entry to Utility Room ................ ND Ilg/ft2 independent Special Safety evaluations, inc. page: 15 of 17
NO = no lead detected. These values are significantly below the federal Risk Assessment (RA) "action-level" (100 1l9/ft2). The Front Porch value is reflective of the condition and lead content of the white paint on the front porch ceiling. The Laboratory's detection limit for this sample is 5 Ilg/ff.
The Assaigai Analytical Laboratories single windowsill dust assay values for:
• Bedroom #1 ........................................... NO Ilg/ff
• Bedroom #2.......... ........ ........ ................. NO 1l9/ft2
• Dining Room .......................................... 13.9 1l9/ft2
Each of these values is below the federal Risk Assessment (RA) "action-level" (500 Ilg/ft\ The Laboratory's detection limit for these samples is 12.4, 11.2, and 12.8 Ilg/ft2 respectively. These extremely low values are reflective of the post WWII paint and a lack of plastic mini-blinds.
With reasonable exterior paint maintenance, and absent any leaded mini-blinds, it has been your iS2e Risk Assessor's experience to find that maintaining windowsill dust lead levels at 10 Ilg/ff or less with quarterly cleaning is quite possible.
E. Lead Contaminated Soil Hazard(s) Identified: NONE (0)
The Assaigai Analytical Laboratories composite bare soil assay values for:
• The dripline ................................................. 14.6 PPM
• The yard soil ............................................... 50.2 PPM
Both of these values are below the lowest federal Risk Assessment (RA) "action level" (400 PPM for high-density children's play area). The prevailing wind is from the SE. One of the yard samples was taken approximately 8 feet from the NE corner of the Carport. The yard lead contamination test result is most certainly reflective of the condition and Pb content in the white exterior soffit and trim paint on wood surfaces of the Carport. Keeping the bare soil covered with sod (grass) near the Carport will suppress any potential hazard. The Laboratory's detection limit for these samples is 5 PPM.
iS2e, inc. routinely finds most soils in residential settings throughout the State fall in the 10-25 PPM range.
F. Lead Water Hazard(s) Identified: NONE (0)
The Assaigai Analytical Laboratories water testing assay value for:
• The Kitchen Sink - "1 51 Draw" ..................... 2.0 Ilg/L independent Special Safety evaluations, inc. page: 16 of 17
The US EPA Standard for "1 S1 Draw" water testing is to take place at the kitchen sink and be the first water from the tap that day. This is to allow time (over night) for the lead (if any) to leach from the water pipes, solder joints, or metal into the drinking/cooking water. The Standard is 15 Ilg/L (millionths of a gram of lead per Liter of water). The test value is unremarkable.
G. Other Lead Hazard(s): NONE (0)
Part VII: Prioritized List of Lead Hazards Identified
C. Recommended Solutions for Lead Hazards Identified:
2. Exterior Lead Paint Hazard #1 :
b. The exterior white paint on the soffit and roof trim of the carport was rated to be in "unsatisfactory" condition, and contains more than 10ft2 of LBP. Only trained and licensed professionals should repair this paint.
C. The exterior white paint on the gable, soffit and roof trim on the south side of this home was also rated to be in "unsatisfactory" condition, and comprised more than 10fe of LBP. Trained and licensed professionals should also only repair this paint.
D. Estimated Costs to Repair Lead Hazards Identified:
2. Exterior Lead Paint Hazard #1 :
c. Cost estimate to repair/repaint the Carport soffit and roof trim is $400.00.
(Approximately 128 ft2)
d. Cost estimate to repair/repaint the south gable, soffit and roof trim is $375.
(Approximately 123 fe) independent Special Safety evaluations, inc. page: 17 of 17 independent Special Safety evaluations, iS2e, inc.
10408 City Lights Dr., NE Albuquerque NM 87111-7536
Customer: us Fish & Wildlife Servo 7333 W. Jefferson Ave.
Lakewood,CO 80235
Action Level 1.000 mg /cm2 Lab 1.000 mg /cm2
ReQort RAW XRF Data
Project Name: Inks Dam NFH Route 2 Burnet,TX 78611
Site Name: Qtrs 73
1961; 1025ft2.
Total Assays Reported
Sample K-Shell L-Shell # Cust Proj Site Identification Number Number mg/cm2 mg/cm2 Calibration
490 0025 0005 0003 .002500050003 1 0.000 X 0.000 X NONE
491 0025 0005 0003 .0830012385642375 1 1.182 K 1.435 L K-Shell
492 0025 0005 0003 .0830012385642375 2 1.242 K 1.359 L K-Shell
493 0025 0005 0003 .0830012385642375 3 1.317 K 1.319 L K-Shell
494 0025 0005 0003 .0830012385642375 4 1.210 K 1.371 L K-Shell
495 0025 0005 0003 .0830012385642375 5 1.293 K 1.382 L K-Shell
496 0025 0005 0003 .0830012385642375 6 1.287 K 1.317 L K-Shell
497 0025 0005 0003 1616281211 1 -0.051 K 0.010 L K-Shell
498 0025 0005 0003 4471412 1 1.415 K 0.313 L K-Shell
499 0025 0005 0003 4481413 1 1.655 K 0.271 L K-Shell
500 0025 0005 0003 1811021214 1 0.618 K 0.333 L K-Shell
501 0025 0005 0003 1031215 1 1.455 K 1.087 L K-Shell
502 0025 0005 0003 1011114 1 0.933 K 0.644 L K-Shell
503 0025 0005 0003 0113471116 1 1.127 K 0.400 L K-Shell
504 0025 0005 0003 3481117 1 0.284 K 0.144 L K-Shell
505 0025 0005 0003 0516281218 1 0.775 K 0.240 L K-Shell
506 0025 0005 0003 0214451419 1 0.927 K 0.370 L K-Shell
507 0025 0005 0003 2011031119 1 1.447 K 0.135 L K-Shell
508 0025 0005 0003 .0830013155642375 1 1.384 K 1.379 L K-Shell
509 0025 0005 0003 2311234119 1 -0.032 K -0.023 L K-Shell
510 0025 0005 0003 2234119 1 0.109 K 0.111 L K-Shell
I Page 1 of 3 Limit Set: 0 Coding Set: 3 I No Averaging Selected
Time Map I
(sec) # '
0.000 0
55.420 375
36.620 375
49.160 375 !
72.150 375
55.430 375
36.600 375 !
13.620 375
24.070 375
26.160 375
24.070 375J
21.970 3751
32.420 375
19.890 375
21.980 375
21.980 375
21.970 375
21.980 375
32.420 375
24.070 375
32.420 375
10408 City Lights Dr., NE Albuquerque NM 87111-7536
Customer: US Fish & Wildlife Servo 7333 W. Jefferson Ave.
Lakewood,CO 80235
Action Level 1.000 mg /cm2 Lab 1.000 mg /cm2
ReI!ort RAW XRF Data
Project Name: Inks Dam NFH Route 2 Burnet,TX 78611
Site Name: Qtrs 73
1961; 1025ft2.
Total Assays Reported
Sample K-Shell L-Shell # Cust Proj Site Identification Number Number mg/cm2 mg/cm2
Calibration
532 0025 0005 0003 1421569 1 -0.159 K -0.099 L K-Shell
533 0025 0005 0003 2931234119 1 -0.204 K 0.027 L K-Shell
534 0025 0005 0003 2234119 1 0.356 K 0.116 L K-Shell
535 0025 0005 0003 3234119 1 0.453 K 0.304 L K-Shell
536 0025 0005 0003 4234119 1 0.126 K 0.151 L K-Shell
537 0025 0005 0003 4411234119 1 0.247 K 0.180 L K-Shell
538 0025 0005 0003 2234119 1 -0.137 K -0.014 L K-Shell
539 0025 0005 0003 3234119 1 0.397 K 0.228 L K-Shell
540 0025 0005 0003 4234119 1 0.122 K 0.103 L K-Shell
541 0025 0005 0003 5082119 1 -0.266 K 0.047 L K-Shell
542 0025 0005 0003 3031119 1 0.001 K 0.057 L K-Shell
543 0025 0005 0003 4111234119 1 -0.102 K 0.010 L K-Shell
S44 0025 0005 0003 2234119 1 -0.218 K -0.114 L K-Shell
545 0025 0005 0003 3234119 1 -0.196 K -0.233 L K-Shell
S46 0025 0005 0003 4234119 1 -0.035 K 0.074 L K-Shell
547 0025 0005 0003 3321119 1 0.234 K -0.014 L K-Shell
548 0025 0005 0003 .0830013585642375 1 1.335 K 1.380 L K-Shell
Page 3 of 3 Limit Set: 0 Coding Set: 3 No Averaging Selected
Time Map (sec) #
11.530 375
28.250 375
26.160 375
24.070 375
26.160 375
21.980 375
26.150 375
26.160 375
26.160 375
28.250 375
21.980 375
30.340 375
19.890 375
19.890 375
26.160 375
19.890 375
32.430 375
10408 City Lights Dr., NE Albuquerque NM 87111-7536
Customer: US Fish & Wildlife Servo 7333 W. Jefferson Ave.
Lakewood,CO 80235
Preliminary XRF
Project Name: Inks Dam NFH Route 2 Burnet,TX 78611
Action Level 1.000 mg Icm2 Lab 1.000 mg Icm2
# Site Room Tested
Living Room
Living Room
Living Room
Living Room
Living Room
Living Room
Page of 3 Limit Set: 0
# I Wall Component Substrate
1 I Rear I Soffit
1 I Rear I Roof Trim
1 I Ceilin I Ceiling
1 L-Sid Interior Wall Sheetrock
1 Rear Interior Wall Sheetrock
1 R-Sid Interior Wall Sheetrock
1 R-Sid Closet Door Aluminum
1 Rear Baseboard Wood
1 Ceilin Ceiling Sheetrock
1 Front Interior Wall Sheetrock
11 Rear I Interior Wall ISheetrock
1 I Front I Cabinets - IWood
Coding Set: 3 I No Averaging Selected
Paint Condition
Good
Good
Fair
Good
Good
Good
Good
Good
Good
Good
I Good
I Good
I
I
Site Name: Qtrs 73 1961; 1025ft2.
Total Assays Reported 50
Result Type L-Shell I Map
K-Shell
1.127K 0.400 L 375 I UNLM I Incl
0.284 K 0.144 L 375 I UNLM I Neg
0.775 K 0.240 L 375 I UNLM I Neg
0.109 K 0.111 L 375 UNLM Neg
0.102 K -0.035 L 375 UNLM Neg
0.113 K 0.136 L 375 UNLM Neg
0.000 K 0.206 L 375 UNLM Neg
0.061 K -0.231 L 375 UNLM
0.276 K 0.317 L 375 UNLM Neg
0.186 K -0.018 L 375 UNLM Neg
0.020 K -0.008 L 375 UNLM Neg
0.238 K -0.038 L 375 UNLM Neg
10408 City Lights Dr., NE Albuquerque NM 87111-7536
Customer: US Fish & Wildlife Servo 7333 W. Jefferson Ave.
Lakewood,CO 80235
Action Level 1.000 mg Icm2 Lab 1.000 mg Icm2
# Site Room Tested # Wall
519 0003 Hallway 1 Floor
52~ 0003 Bath - Fun 1 R-Sid
521 0003 Bath -Fun 1 R-Sid
52:.! 0003 Bedroom 1 Front
52~ 0003 Bedroom 1 L-Sid
524 0003 Bedroom 1 Rear
525 0003 Bedroom 1 R-Sid
52E 0003 Bedroom 1 Ceilin
52' 0003 Bedroom 2 Front
52fi 0003 Bedroom 2 L-Sid
529 0003 Bedroom 2 Rear
53~ 0003 Bedroom 2 R-Sid
531 0003 Bedroom 2 Front
53 0003 Bedroom 2 Front
533 0003 Bedroom 3 Front
534 0003 Bedroom 3 L-Sid
53~ 0003 Bedroom 3 Rear
53' 0003 Bedroom 3 R-Sid
53~ 0003 UtillLaundry 1 Front
538 0003 UtillLaundry 1 L-Sid
539 0003 UtillLaundry 1 Rear
Page 2 of 3 Limit Set: 0 Coding Set: 3
Preliminary XRF
Project Name: Inks Dam NFH Route 2 Burnet, TX 78611
Component Substrate
Floor - Carpet Concrete
Backsplash Tile
Interior Wan Sheetrock
Interior Wan Sheetrock
Interior Wan Sheetrock
Interior Wan Sheetrock
Interior Wan Sheetrock
Ceiling Sheetrock
Interior Wan Sheetrock
Interior Wan Sheetrock
Interior Wan Sheetrock
Interior Wan Sheetrock
Interior Door Wood
Interior Door Wood
Interior Wan Sheetrock
Interior Wan Sheetrock
Interior Wan Sheetrock
Interior Wan Sheetrock
Interior Wan Sheetrock
Interior Wan Sheetrock
Interior Wan Sheetrock
No Averaging Selected
Paint Condition
Good
Good
Good
Good
Good
Good
Good
Good
Good
Good
Good
Good
Good
Stain
Good
Good
Good
Good
Good
Good
Good
Site Name: Qtrs 73 1961; 1025ft2.
Total Assays Reported 50
K-Shell L-Shell Map mw'cm2 mg/cm2 # Type Result
-6.097 K -0.126 L 375 UNLM Neg
0.079 K -1.472 L 375 UNLM Neg
0.155 K 0.171 L 375 UNLM Neg
0.036 K 0.003 L 375 UNLM Neg
0.074 K 0.182 L 375 UNLM Neg
-0.032 K 0.058 L 375 UNLM Neg
0.252 K 0.130 L 375 UNLM Neg
0.153 K -0.038 L 375 UNLM Neg
0.000 K 0.105 L 375 UNLM Neg
0.219 K 0.125 L 375 UNLM Neg
0.045 K 0.008 L 375 UNLM Neg
0.179 K 0.067 L 375 UNLM Neg
0.074 K -0.051 L 375 UNLM Neg
-0.159 K -0.099 L 375 UNLM Neg
-6.204 K 0.027 L 375 UNLM Neg
0.356 K 0.116 L 375 UNLM Neg
0.453 K 0.304 L 375 UNLM Neg
0.126 K 0.151 L 375 UNLM Neg
0.247 K 0.180 L 375 UNLM Neg
-0.137 K -0.014 L 375 UNLM Neg
0.397 K 0.228 L 375 UNLM Neg
10408 City Lights Dr., NE Albuquerque NM 87111-7536
Customer: US Fish & Wildlife Servo 7333 W. Jefferson Ave.
Lakewood,CO 80235
Action Level 1.000 mg Icm2 Lab 1.000 mg Icm2
# Site Room Tested # Wall
540 0003 UtillLaundry 1 R-Sid
541 0003 UtillLaundry 1 Floor
542 0003 UtillLaundry 1 Rear
543 0003 Kitchen 1 Front
544 0003 Kitchen 1 L-Sid
545 0003 Kitchen 1 Rear
54' 0003 Kitchen 1 R-Sid
547 0003 Kitchen 1 Rear
Page 3 of 3 Limit Set: 0 Coding Set: 3
Preliminary XRF
Project Name: Inks Dam NFH Route 2 Burnet, TX 78611
Component Substrate
Interior Wall Sheetrock
Floor- Tile
DoorJamb lWood
Interior Wall Sheetrock
Interior Wall Sheetrock
Interior Wall Sheetrock
Interior Wall Sheetrock
Kitchen Wood
No Averaging Selected
Paint Condition
Good
Good
Good
Good
Good
Good
Good
Good
Site Name: Qtrs 73 1961; 1025ft2.
Total Assays Reported 50
K-Shell L-Shell Map mg/cm2 mg/cm2 # Type Result
0.122 K 0.103 L 375 UNLM Neg
-0.266 K 0.047 L 375 UNLM Neg
0.001 K 0.057 L 375 UNLM Neg
-0.102 K 0.010 L 375 UNLM Neg
-0.218 K -0.114 L 375 UNLM Neg
-0.196 K -0.233 L 375 UNLM Neg
-0.035 K 0.074 L 375 UNLM Neg
0.234 K -0.014 L 375 UNLM Neg
Project independent Special Safety evaluations, iS2e, inc.
10408 City Lights Dr., NE Albuquerque NM 87111-7536
I Site Date
0002 08/30/00
0002 08/30/00
0002 08/30/00
0002 08/30/00
0002 08/30/00
0002 08/30/00
0002 08/30/00
0002 08/30/00
0002 08/30/00
0003 08/30/00
0003 08/30/00
0003 08/30/00
0003 08/30/00
0003 08/30/00
0003 08/30/00
0003 08/30/00
0003 08/30/00
Time
06:54A
06:55A
06:55A
07:02A
08:58A
09:49A
10:22A
10:23A
10:24A
11:37A
11:38A
11:39A
11:42A
11:43A
11:45A
12:12P
12:55P
Daily Calibration
K-Shell K-Avg. L-Shell L-Avg. Scanner Instr Oper mg/cm2 mg/cm2 mg/cm2 mg/cm2 # #
1.212 1.212 1.405 1.405 M41375 375 5642
1.307 1.307 1.320 1.320 M41375 375 5642
1.357 1.357 1.338 1.338 M41375 375 5642
1.409 1.409 1.412 1.412 M41375 375 5642
1.470 1.470 1.389 1.389 M41375 375 5642
1.352 1.352 1.393 1.393 M41375 375 5642
1.168 1.168 1.377 1.377 M41375 375 5642
1.296 1.296 1.353 1.353 M41375 375 5642
1.299 1.299 1.385 1.385 M41375 375 5642
1.182 1.182 1.435 1.435 M41375 375 5642
1.242 1.242 1.359 1.359 M41375 375 5642
1.317 1.317 1.319 1.319 M41375 375 5642
1.210 1.210 1.371 1.371 M41375 375 5642
1.293 1.293 1.382 1.382 M41375 375 5642
1.287 1.287 1.317 1.317 M41375 375 5642
1.384 1.384 1.379 1.379 M41375 375 5642
1.335 1.335 1.380 1.380 M41375 375 5642
10408 City Lights Dr., NE Albuquerque NM 87111-7536
Single Family HUD Data Sheet
Customer: US Fish & Wildlife Servo 7333 W. Jefferson Ave.
Lakewood,CO 80235
Action Level 1.000 mg Icm2 Lab 1.000 mg Icm2
Map Room Tested # Wall Component # Grp
375 Ext. Front 1 (GX) Rear Soffit
375 Ext. Front 1 (GX) Rear Roof Trim
375 Ext. L-Side 1 (GX) R-Sid Exterior Wan
375 Front Porch 1 (GX) Ceilin Ceiling
375 Carport 1 (GX) Ceilin Ceiling
375 Carport 1 (GX) R-Sid Soffit
375 Carport 1 (GX) R-Sid Roof Trim
375 Storage 1 (GX) Front Entry Door (bit.)
375 Storage 1 (GX) Front Entry Door (ext.)
375 Storage 1 (GX) Front DoorJamb
375 Entry/Foye 1 (GX) Front DoorJamb
375 Hallway 1 (GX) Floor Floor - Carpet
375 Hanway 1 (GX) Front Interior Wan
375 Hallway 1 (GX) Rear Interior Wan
375 Hallway 1 (GX) Front Cabinets -
375 Living 1 (GX) Rear Baseboard
375 Living 1 (GX) R-Sid Closet Door
375 Living 1 (GX) Front Interior Wan
375 Living 1 (GX) L-Sid Interior Wan
375 Living 1 (GX) Rear Interior Wan
Project Name: Inks Dam NFH Route 2 Burnet,TX 78611
Substrate Paint Color
Wood White
Wood White
Wood White
Wood White
Wood White
Wood White
Wood White
Wood White
Wood White
Wood White
Wood White
Concrete Brown
Sheetrock White
Sheetrock White
Wood White
Wood White
Aluminum White
Sheetrock White
Sheetrock White
Sheetrock White
[page 1 of 3 Limit Set: 0 Coding Set: 3 I Straight average
Site Name: Qtrs 73 1961; 1025ft2.
Total Assays Reported
Paint K-Shell Cond mg/cm2
Average Lab
Good 1.127 K 1.127
Good 0.284 K 0.284
Unsat 0.927 K 0.927
Fair 0.775 K 0.775
Fair -0.051 K -0.051
Unsat 1.415 K 1.415
Unsat 1.655 K 1.655
Good 0.933 K 0.933
Fair 0.618 K 0.618
Fair 1.455 K 1.455
Good 1.447 K 1.447
Good -0.097 K -0.097
Good 0.186 K 0.103
Good 0.020 K
Good 0.238 K 0.238
Good 0.061 K 0.061
Good 0.000 K 0.000
Good -0.032 K 0.073
Good 0.109 K
Good 0.102 K
Result
Incl
Neg
IncI
Neg
Neg
Pos
Pos
Incl
Neg
Pos
Pos
Neg
Neg
Neg
Neg
Neg
10408 City Lights Dr., NE
Single Family HUD Data Sheet . Albuquerque NM 87111-7536
Customer: US Fish & Wildlife Servo 7333 W. Jefferson Ave.
Lakewood,CO 80235
Action Level 1.000 mg /cm2 Lab 1.000 mg/cm2
Map Room Tested # Grp Wall Component #
375 Living 1 (GX) R-Sid Interior Wall
375 Living 1 (GX) Ceilin Ceiling
375 Bedroom 1 (GX) Front Interior Wall
375 Bedroom 1 (GX) L-Sid Interior Wall
375 Bedroom 1 (GX) Rear Interior Wall
375 Bedroom 1 (GX) R-Sid Interior Wall
375 Bedroom 2 (GX) Front Interior Wall
375 Bedroom 2 (GX) L-Sid Interior Wall
375 Bedroom 2 (GX) Rear Interior Wall
375 Bedroom 2 (GX) R-Sid Interior Wall
375 Bedroom 3 (GX) Front Interior Wall
375 Bedroom 3 (GX) L-Sid Interior Wall
375 Bedroom 3 (GX) Rear Interior Wall
375 Bedroom 3 (GX) R-Sid Interior Wall
375 Bedroom 1 (GX) Ceilin Ceiling
375 Bedroom 2 (GX) Front Interior Door
375 Bedroom 2 (GX) Front Interior Door
375 Bath - Full 1 (GX) R-Sid Interior Wall
375 Bath- Full 1 (GX) R-Sid Backsplash
375 Kitchen 1 (GX) Front Interior Wall
375 Kitchen 1 (GX) L-Sid Interior Wall
Page 2 of 3 Limit Set: 0 Coding Set: 3
Project Name: Inks Dam NFH Route 2 Burnet,TX 78611
Substrate Paint…