About this file
This document is a set of Final Construction Drawings for upgrading the fire detection and security system on the Maintenance Building at Scotts Bluff National Monument in Gering, Nebraska. The drawings, prepared by Kenneth Hahn Architects and Alvine Engineering, provide detailed plans, elevations, and specifications for the electrical, fire alarm, and intrusion alarm system upgrades. Key details include:
The project entails installing new fire alarm and intrusion alarm devices and upgrading the existing system. The drawings indicate locations for new fire alarm notification devices, cameras, conduits, panels, and other electrical work. General notes cover requirements for protecting existing historic building materials, field verifying dimensions, coordinating with other trades, compliance with codes, and providing a finished and complete project. The project is identified with the PMIS number 227334.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140P6324Q0014_Amd_0002.pdf | ||
| Atch_7_Site_Visit_Sign-in_Sheet_0002.pdf | ||
| Atch_6_Questions_and_Answers_0002.docx | DOCX document | |
| Sol_140P6324Q0014_Amd_0001.pdf | ||
| Atch_3_SOW_Drawings-8_pages_0001.pdf | ||
| Atch_4_Experience_Questionnaire.xls | XLS spreadsheet | |
| Atch_1_SOW_Div_1.pdf | ||
| Sol_140P6324Q0014.pdf | ||
| Atch_5_DOL_Wage_Determination_NE20240079.pdf | ||
| Atch_2_SOW_Div_2_thru_49.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCOTTS BLUFF
STATE
NATIONAL PARK SERVICE
DENVER SERVICE CENTER
REGION COUNTY
DEPARTMENT OF THE INTERIOR
UNITED STATES
TITLE OF DRAWING
OF
PKG.
NO.
SHEET
DRAWING NO.
317/
MIDWEST
COVER SHEET
QUALITY DESIGN CERTIFICATION
OR
OR
Development (Title I)
Prepared in Accordance with Design by Design Development (Title I)
Construction Drawing Not Preceded
Approved by Superintendent on
Variance from Design Development (Title I)
Project Manager
Drawing No.
Date
Date
SheetMark REVISION Date Initial
NA
NA
80037
KENNETH HAHN
ARCHITECTS
NO. 145-091
A/E FIRM - A/E CONTRACT NO.
PRIME/ARCH:
KENNETH HAHN ARCHITECTS
OMAHA, NE
MEP:
ALVINE ENGINEERING
OMAHA, NE
GERING, NEBRASKA
UPGRADE FIRE DETECTION & SECURITY
SYSTEM ON MAINTENANCE BUILDING
NAME OF PARK
NEBRASKA
INDEX OF DRAWINGS
1. TS1 COVER SHEET
2. A1 MAINTENANCE BLDG.- FLOOR PLAN,
LOFT PLAN, PHOTOS
3. E0 ELECTRICAL SYMBOLS, ABBREVIATIONS, AND NOTES
4. E01 SITE PLAN - ELECTRICAL
5 ED1 FIRE ALARM/INTRUSION ALARM DEMOLITION PLANS
6. E1 FIRE ALARM/INTRUSION ALARM - NEW WORK
7. E2 VISITOR CENTER FIRST FLOOR FIRE ALARM / INTRUSION ALARM
8. E3 ELECTRICAL DETAILS AND SCHEDULES
NATIONAL
SERVICE
PARK
FINAL CONSTRUCTION DOCUMENTS
2/23/2024 PMIS 227334
NATIONAL MONUMENT
SCOTTS BLUFF
NATIONAL MONUMENT
1. THE CONTRACTOR SHALL PROTECT EXISTING BUILDING AND
SITE MATERIALS SCHEDULED TO REMAIN, AND SHALL BE
RESPONSIBLE FOR DAMAGE TO SAME RESULTING FROM WORK
UNDER THIS CONTRACT. THE CONTRACTOR SHALL RESTORE
DAMAGED EXISTING BUILDING AND SITE MATERIALS TO THEIR
ORIGINAL CONDITION.
2. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND
SHALL BE RESPONSIBLE FOR THE SAME. COORDINATE ALL
WORK AND SHOP DRAWINGS WITH OTHER TRADES.
3. INFORMATION PERTAINING TO THE EXISTING BUILDING HAS
BEEN OBTAINED THROUGH THE BUILDING'S ORIGINAL
DRAWINGS, WHERE AVAILABLE. REPORT DISCREPANCIES TO
THE CONTRACTING OFFICER PRIOR TO ANY DEMOLITION.
CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS
PRIOR TO COMMENCING WORK.
4. THE CONTRACTOR SHALL COORDINATE ALL TESTING AND
INSPECTIONS AS SPECIFIED, OR AS NECESSARY TO
DEMONSTRATE A COMPLETE AND SATISFACTORY
INSTALLATION.
5. THE CONTRACTOR SHALL COORDINATE ON-SITE STORAGE OF
BUILDING MATERIALS, EQUIPMENT, AND TRASH CONTAINERS
WITH THE PARK.
6. ALL WORK SHALL COMPLY WITH LOCAL CODES AND ALL OTHER
APPLICABLE CODES, REGULATIONS, AND ORDINANCES.
7. ALL MATERIALS AND EQUIPMENT OF THE SAME TYPE SHALL BE
SUPPLIED BY THE SAME MANUFACTURER, AND SHALL BE NEW,
OF THE BEST QUALITY AND DESIGN, AND FREE FROM DEFECTS.
8. ALL ITEMS ARE NEW UNLESS SPECIFICALLY IDENTIFIED AS
EXISTING.
9. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF
ALL WORK. CONTRACTOR SHALL ANTICIPATE AREAS WHERE
THE INSTALLATION OF MECHANICAL AND ELECTRICAL WORK
WILL BE RESTRICTED, CONGESTED, OR DIFFICULT TO INSTALL,
AND SHALL COORDINATE INSTALLATION BETWEEN THE
TRADES.
10. CONTRACTOR SHALL COORDINATE LOCATIONS FOR ALL
MECHANICAL AND ELECTRICAL ITEMS WITH EXISTING
CONDITIONS AND NEW WORK. CONTRACTOR SHALL NOTIFY
THE CONTRACTING OFFICER OF ANY DISCREPANCIES PRIOR
TO INSTALLATION AND/OR FABRICATION.
11. IT IS THE INTENT OF THIS CONTRACT THAT ALL AREAS
AFFECTED BY CONSTRUCTION SHALL PROVIDE A FINISHED
AND COMPLETE PROJECT, UNLESS NOTED OTHERWISE.
CONTRACTOR SHALL PATCH, REPAIR, AND ADJUST AS
REQUIRED TO ACHIEVE THIS FINISHED PROJECT.
12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING
ALL WORK AND PROVIDING ALL MATERIALS REQUIRED TO
ACHIEVE THE DESIGN INTENT SHOWN ON THESE DRAWINGS.
THE GOVERNMENT WILL NOT BE RESPONSIBLE FOR ANY
ADDITIONAL EXPENSE TO THE CONTRACTOR IF THE
CONDITIONS CAUSING THOSE EXPENSES COULD HAVE BEEN
DISCOVERED IN AN ON-SITE INSPECTION PRIOR TO BID
SUBMITTAL.
13. THE BUILDING, LANDSCAPE AND SURROUNDINGS ARE ON THE
NATIONAL REGISTER OF HISTORIC PLACES. THE ENTIRE SITE IS
A HISTORIC PROPERTY AND ALL REASONABLE PRECAUTIONS
SHALL BE TAKEN TO PREVENT COLLATERAL DAMAGE TO
HISTORIC MATERIALS SURROUNDING THE WORK AREA. IF
DAMAGE OCCURS, REPAIRS SHALL BE MADE AT NO
ADDITIONAL COST TO THE GOVERNMENT TO THE
SATISFACTION OF THE CONTRACTING OFFICER. EVERY
OPPORTUNITY SHOULD BE TAKEN TO PRESERVE, REPAIR AND
CONSERVE HISTORIC MATERIALS AND DESIGNS. COORDINATE
ALL NEW PENETRATIONS AND ANY ALTERATIONS TO THE
BUILDING WHICH MIGHT AFFECT THE HISTORIC INTEGRITY OF
THE BUILDING WITH THE CONTRACTING OFFICER PRIOR TO
BEGINNING WORK.
14. "REMOVE" MEANS TO DEMOLISH AND DISPOSE OF AN ITEM OFF
OF NPS PROPERTY.
GENERAL NOTES
AREA MAP
SCOTTS BLUFF NATIONAL MONUMENT - MAPS
REGION MAP
PROJECT SITEPROJECT SITE
SCOTTS BLUFF
NEBRASKAWYOMING
SITE MAP
PROJECT SITE:
MAINTENANCE BUILDING
ADMINISTRATION
BUILDING
VISITOR CENTER
STEPHEN R SMITH, AIA
KENNETH HAHN ARCHITECTS INC
2/23/2024
ARCHITECT
I, STEPHEN SMITH, AM THE COORDINATING PROFESSIONAL
ON THE COVER AND A1.
BRANDON D RICH, PE
ALVINE ENGINEERING
2/23/2024
ENGINEER
I, BRANDON RICH, AM THE COORDINATING PROFESSIONAL
ON THE COVER AND E0,E01,ED1,E1,E2,E3
BAY
PARKING BAY
OFFICE
101B
WORKSHOP
STALL
SHOP
STALL
LUNCH
ROOM
OFFICE
RR
I.T. RM
OFFICE
LOFT
LOFT
OFFICE
SL
OP
ED
C
LG
SL
OP
ED
C
LG
SL
OP
ED
C
LG
SL
OP
ED
C
LG
SL
OP
ED
C
LG
SL
OP
ED
C
LG
SL
OP
ED
C
LG
SL
OP
ED
C
LG
SL
OP
ED
SL
OP
ED
SL
OP
ED
SL
OP
ED
SL
OP
ED
C
LG
SL
OP
ED
SL
OP
ED
LOFT ABOVE SHOWN DASHED;
SEE LOFT PLAN 2/A1
A1
MAINTENANCE BLDG.- FLOOR
PLAN, LOFT PLAN, PHOTOS
SCALE: 1/8" = 1'-0" 8' 4' 0 8'
FLOOR PLAN
N
PROJECT
NORTH
TRUE
NORTH
N
SCALE: 1/8" = 1'-0" 8' 4' 0 8'
LOFT LEVEL FLOOR PLAN
N
F e b a m
C
T o d d A
K
H A w o r k p a r k s
A l a r m s a n d
F i r e
P r o t e c t i o n S
C B
L D
R A
W I N
G S
S
C B
L A d w g
U
S E
R t o d d
SUB SHEET NO.
OF
DESIGNED:
KJH
UPGRADE FIRE DETECTION & SECURITY SYSTEM ON
MAINTENANCE BUILDING
SCOTTS BLUFF NATIONAL MONUMENT
SCOTTS BLUFF, NE
317/80037
227334
DRAWN BY:
TECH. REVIEW:
DATE:
2/23/2024
DRAWING NO.
PMIS NO.
SHEET
TITLE OF SHEET
A/E FIRM
PRIME:
KENNETH HAHN
ARCHITECTS, INC.
OMAHA, NE.
SUBCONTRACTOR:
ALVINE
ENGINEERING
OMAHA, NE.
CLZ
TWM
FINAL CONSTRUCTION DOCUMENTS
LOCATE FIRE ALARM NOTIFICATION
DEVICE/CAMERA UNDER EAVE WITH
CLEAR LINE OF SIGHT. INSTALL
WEATHERTIGHT. SEE ELECTRICAL.
KEYED NOTES
REPAIR/PATCH AND PAINT WHERE
DEVICE WAS REMOVED AND NOT
REPLACED. FINISH AREA TO MATCH
ADJACENT SURFACE.
GENERAL NOTES
G1. PAINT ALL NEW CEILING/WALL
MOUNTED CONDUIT TO MATCH
ADJACENT SURFACE IF THE
MOUNTING SURFACE IS ALREADY
PAINTED.
G2. INSTALL SURFACE MOUNTED
CONDUIT IN A NEAT AND ORDERLY
MANNER. DO NOT RUN CONDUIT
DIAGONALLY. SEE ELECTRICAL
DRAWINGS AND SPECIFICATIONS.
G3. PATCH/REPAIR/PAINT CEILING/WALL
FINISHES AS REQUIRED TO MATCH
ADJACENT AREA WHERE NEW
DEVICES DON'T COMPLETELY
COVER OLD DEVICE LOCATIONS.
G4. PATCH CEILING/WALL WHERE A
DEVICE/CONDUIT/PANEL WAS
REMOVED AND NOT REPLACED AT
THE SAME LOCATION.
G5. WHERE PAINTING IS REQUIRED DUE
TO REMOVAL/ DEMOLITION/
PATCHING; PAINT ENTIRE CEILING/
WALL PLANE CORNER TO CORNER,
EDGE TO EDGE. PAINT COLOR AND
FINISH TO MATCH ADJACENT
CEILING/ WALL.
PATCH/REPAIR AND PAINT WALL
WHERE PANEL WAS REMOVED AND
NOT REPLACED. SEE ELECTRICAL.
LOOKING WEST
LOOKING NORTH -EAST END
LOOKING NORTH- WEST END
5 45 4
11 1 1
PROVIDE CUT OUTS AND BLOCKING
FOR NEW PANELS. PATCH/REPAIR
AND PAINT AS REQUIRED. SEE
ELECTRICAL.
| Sheets and Views |
| TS1 |
File details come from the government source that posted it. Updated .