Atch 01 Rqmt Doc_DRMS TWTAs.pdf

PDF 756 KB Posted

Attached to
Traveling Wave Tube Amplifiers Federal contract opportunity
Solicitation number
FA9101-20-Q-2019
Issued by
Department of the Air Force Materiel Command Test Center

About this file

This requirements document outlines the need for eight traveling wave tube amplifiers and optional spare amplifiers to support the National Radar Cross Section Test Facility Dynamic RCS Measurement System. The Air Force Materiel Command Test Center is seeking two amplifiers each for the S and Ku bands, with pulse widths between 50-50,000 nanoseconds, peak output power of 6 kW, and gain of at least 70 dB. Delivery is required no later than March 31, 2022 for the initial amplifiers and 18 months after option exercise for any spares. The contractor must meet technical and documentation requirements and provide regular status reports, schedule updates, and documentation for acceptance including assembly drawings, training materials, and operations/maintenance manuals.

View the file

Other files for this federal contract opportunity

Other files attached to Traveling Wave Tube Amplifiers, newest first.
File Type Posted
FA9101-20-Q-2019_QnA.pdf PDF
Atch 01 Rqmt Doc_DRMS TWTAs_Rev 1.pdf PDF
Atch 02_FAR DFARS AFFARS Prov and Clauses.pdf PDF
1 FA9101-20-Q-2019_Combined Synopsis Solicitation.pdf PDF
Atch 04_Past Perf Quest.docx DOCX document
Atch 03_Evaluation Plan.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Requirements Document

FOR

National Radar Cross Section Test Facility (NRTF)

Dynamic RCS Measurement System (DRMS)

High Power Amplifier(s)

TABLE OF CONTENTS

1. INTRODUCTION

2. DELIVERY

3. PROJECT SCHEDULE

4. TECHNCAL INTERCHANGE AND ACCEPTANCE

5. REQUIRED DOCUMENTS

6. CONTRACTOR CONTACT INFORMATION

1. INTRODUCTION

The US Air Force, National Radar Cross-Section Test Facility (NRTF) is pursuing a multi-phase development of an S-Ku band Tier IV Dynamic RCS Measurement System (DRMS) at White Sands

NM to augment the current test facility. The DRMS will use dedicated wideband coherent octave traveling wave tube amplifiers (TWTAs) per radar band and per polarization. The Contractor’s shall meet the minimum requirements stated in the Requirements Documents, appendices 1-4.

S-Ku Band DRMS TWTA Specifications TR#001-046

Transmitter Control Ethernet Interface

The Requirements Document and the associated technical appendicies are to provide the requirements to define the TWTAs necessary to meet DRMS requirements. The DRMS system will initially procure a total of eight (8) TWTAs, two (2) per band with the option to purchase four (4) additional spare TWTAs (one (1) per band), as needed, up to a maximum of 12 total TWTAs on this acquisition.

2. DELIVERY

Delivery requirements for the TWTS are as follows:

1. Eight (8) TWTAs: No later than Mar 31, 2022.

2. Option 1 (Date of award to 24 months), Four (4) spare TWTAs: Due no later than 18 months after exercise of the option.

3. PROJECT SCHEDULE

The Contractor shall provide a complete milestone schedule that denotes major activities, demonstrations, and acceptance testing.

4. TECHNCAL INTERCHANGE AND ACCEPTANCE

The contractor shall conduct the following reviews with Government representatives:

Kick-off/ Technical Interchange Meeting (TIM)

Mid-Term Program Management and Progress Meeting

Physical Configuration Audit (PCA)/Factory Acceptance Test (FAT)

Assembly Drawings

Technical Theory, Operation and Maintenance Training and Manuals

These meeting shall be conducted in a format of the Contractor’s choosing and shall cover the overall technical approach, constraints, methods and techniques being examined, performance metrics and results.

5. REQUIRED DOCUMENTS

The Contractor shall provide performance to plan status reports and schedule updates to the AF

Project Manager per the frequency in Table 5-1. All documents are subject to Government acceptance and approval.

Table 5.1 Reporting Requirements

6. CONTRACTOR CONTACT INFORMATION

Upon notice of award, the Contractor shall provide the Contracting Officer and the Government

Project Manager the names and contact information (address, phone number, and email) of a minimum of two (2) Contractor representatives, preferably the contracting agent and project leader.

Any changes in the contact information will immediately be updated by the Contractor as they occur during the duration of this contract and be provided to the Contracting Officer and the

Government Project Manager.

Document Format Frequency

Project Status

Report

MS Word document or email Quarterly

Milestone Schedule MS Project, Word, or Excel file

Updated Quarterly

PCA Results MS Word 30 Days post milestone

FAT Results MS Word 30 days post milestone

Training Docs MS PowerPoint 30 days post milestone

Assembly

Drawings

IGES or STL Compatible 30 days post PCA/FAT

Operations and

Maintenance

Manuals

Word or PDF 30 days post PCA/FAT

Requirements: Specification Description Specification Compliance Pass/Fail

S-001 Freq Range (GHz) 2 - 4 (Instantaneous BW)

S-002 Minimum Peak Output Power (Watts) 6 kW @ all frequencies

S-003 Typical Gain @ Rated Power Out (dB) 70

S-004 Minimum Duty Cycle Rating (%) 6%

S-005 Modulation AM/FM/Pulse

S-006 Output Power On/Off Delta (dB) >80

S-007 Pulse Width Range (ns) 50 to 50,000

S-008 Max PRF (kHz) 100

S-009 RF In for Rated Pwr Out (dBm) 0

S-010 RF Droop Across Pulse Width (dB) < 0.5

S-011 RF Pulse to Pulse Stability (dB) 0.1

S-012 Max RF Pulse Overshoot (% of Avg Pwr) 5

S-013 RF In to Out Max Pulse Delay (ns) 500

S-014 RF Pulse to Pulse Phase Stability (°) ±1

S-015 Max RF Output Pulse Rise/Fall Time (ns) 20

S-016 RF Pulse to Pulse Recovery Time (ns) 150

S-017 I/O Impedance (Ω) 50

S-018 I/O VSWR 2.0:1

S-019 Spurious Output w/in 1 MHz (dBc) <-50

S-020 Tx Bkt (Gating) Pulse Input Type 5V TTL

S-021 Tx Bkt Max Pulse to Pulse Jitter (ns) ±5

S-022 Tx Bkt Max Pulse Width Jitter (ns) ±5

S-023 RF Input Sample Coupled Output (dB) 20

S-024 RF Output Sample Coupled Output (dB) 60

S-025 RF Input Connectors N - F

S-026 RF Sample Output Connectors N - F

S-027 RF High Power Output Connector SC - F

S-028 Tx Bkt Input Connector BNC - F

S-029 Connector Location (Pwr,RF,TTL,Ethernet) Rear Panel

S-030 Chassis Form Factor

19" Rack Mount, 30" Deep Max. 40"

Heigth Max

S-031 Chassis Vertical Rack Units Specify RU's (or Inches) in Bid

S-032 Prime Power 208 VAC, 3 Ph, 60 Hz

S-033 Chassis Cooling Type Internal Forced Air

S-034 Operating Temperature Range (°C) -10 to 50

S-035 Operating Altitude (Ft Above Sea Level) 10,000

S-036 Storage Temperature Range (°C) -20 to 70

S-037 Command and Control Methods Local and Remote

S-038 Local Control with Front Panel Readout Push Button/Touch

S-039 Power On/Off Switch or Breaker Front Panel

S-040 Remote Control Interface Ethernet IP (Static Config)

S-041 Bit/Byte Decoding for Control/Status To Be Defined by RTT

S-042 VSWR Protection for Source/Load Mismatch No Damage or Oscillation

S-043 TWT Protection in Addition to VSWR Arc,Temp,Over-Volt/Current

S-044 Additional Status and Fault monitoring for: Power Voltages and Currents

S-045 Remote Control of Power On/Off In Addition to Standby/Operate

S-046 Power Up BIT Auto w/Results Status

S Band

S-001 Freq Range (GHz) 4 - 8 (Instantaneous BW)

S-002 Minimum Peak Output Power (Watts) 6 kW @ all frequencies

S-003 Typical Gain @ Rated Power Out (dB) 70

S-004 Minimum Duty Cycle Rating (%) 6%

S-005 Modulation AM/FM/Pulse

S-006 Output Power On/Off Delta (dB) >80

S-007 Pulse Width Range (ns) 50 to 50,000

S-008 Max PRF (kHz) 100

S-009 RF In for Rated Pwr Out (dBm) 0

S-010 RF Droop Across Pulse Width (dB) < 0.5

S-011 RF Pulse to Pulse Stability (dB) 0.1

S-012 Max RF Pulse Overshoot (% of Avg Pwr) 5

S-013 RF In to Out Max Pulse Delay (ns) 500

S-014 RF Pulse to Pulse Phase Stability (°) ±1

S-015 Max RF Output Pulse Rise/Fall Time (ns) 20

S-016 RF Pulse to Pulse Recovery Time (ns) 150

S-017 I/O Impedance (Ω) 50

S-018 I/O VSWR 2.0:1

S-019 Spurious Output w/in 1 MHz (dBc) <-50

S-020 Tx Bkt (Gating) Pulse Input Type 5V TTL

S-021 Tx Bkt Max Pulse to Pulse Jitter (ns) ±5

S-022 Tx Bkt Max Pulse Width Jitter (ns) ±5

S-023 RF Input Sample Coupled Output (dB) 20

S-024 RF Output Sample Coupled Output (dB) 60

S-025 RF Input Connectors N - F

S-026 RF Sample Output Connectors N - F

S-027 RF High Power Output Connector SC - F

S-028 Tx Bkt Input Connector BNC - F

S-029 Connector Location (Pwr,RF,TTL,Ethernet) Rear Panel

S-030 Chassis Form Factor

19" Rack Mount, 30" Deep Max, 40"

Heigth Max

S-031 Chassis Vertical Rack Units Specify RU's (or Inches) in Bid

S-032 Prime Power 208 VAC, 3 Ph, 60 Hz

S-033 Chassis Cooling Type Internal Forced Air

S-034 Operating Temperature Range (°C) -10 to 50

S-035 Operating Altitude (Ft Above Sea Level) 10,000

S-036 Storage Temperature Range (°C) -20 to 70

S-037 Command and Control Methods Local and Remote

S-038 Local Control with Front Panel Readout Push Button/Touch

S-039 Power On/Off Switch or Breaker Front Panel

S-040 Remote Control Interface Ethernet IP (Static Config)

S-041 Bit/Byte Decoding for Control/Status To Be Defined by RTT

S-042 VSWR Protection for Source/Load Mismatch No Damage or Oscillation

S-043 TWT Protection in Addition to VSWR Arc,Temp,Over-Volt/Current

S-044 Additional Status and Fault monitoring for: Power Voltages and Currents

S-045 Remote Control of Power On/Off In Addition to Standby/Operate

C Band

S-001 Freq Range (GHz) 8 - 12 (Instantaneous BW)

S-002 Minimum Peak Output Power (Watts) 6 kW @ all frequencies

S-003 Typical Gain @ Rated Power Out (dB) 70

S-004 Minimum Duty Cycle Rating (%) 6%

S-005 Modulation AM/FM/Pulse

S-006 Output Power On/Off Delta (dB) >80

S-007 Pulse Width Range (ns) 50 to 50,000

S-008 Max PRF (kHz) 100

S-009 RF In for Rated Pwr Out (dBm) 0

S-010 RF Droop Across Pulse Width (dB) < 0.5

S-011 RF Pulse to Pulse Stability (dB) 0.1

S-012 Max RF Pulse Overshoot (% of Avg Pwr) 5

S-013 RF In to Out Max Pulse Delay (ns) 500

S-014 RF Pulse to Pulse Phase Stability (°) ±1

S-015 Max RF Output Pulse Rise/Fall Time (ns) 20

S-016 RF Pulse to Pulse Recovery Time (ns) 150

S-017 I/O Impedance (Ω) 50

S-018 I/O VSWR 2.0:1

S-019 Spurious Output w/in 1 MHz (dBc) <-50

S-020 Tx Bkt (Gating) Pulse Input Type 5V TTL

S-021 Tx Bkt Max Pulse to Pulse Jitter (ns) ±5

S-022 Tx Bkt Max Pulse Width Jitter (ns) ±5

S-023 RF Input Sample Coupled Output (dB) 20

S-024 RF Output Sample Coupled Output (dB) 60

S-025 RF Input Connectors N - F

S-026 RF Sample Output Connectors N - F

S-027 RF High Power Output Connector SC - F

S-028 Tx Bkt Input Connector BNC - F

S-029 Connector Location (Pwr,RF,TTL,Ethernet) Rear Panel

S-030 Chassis Form Factor

19" Rack Mount, 30" Deep Max, 40"

Heighth Max

S-031 Chassis Vertical Rack Units Specify RU's (or Inches) in Bid

S-032 Prime Power 208 VAC, 3 Ph, 60 Hz

S-033 Chassis Cooling Type Internal Forced Air

S-034 Operating Temperature Range (°C) -10 to 50

S-035 Operating Altitude (Ft Above Sea Level) 10,000

S-036 Storage Temperature Range (°C) -20 to 70

S-037 Command and Control Methods Local and Remote

S-038 Local Control with Front Panel Readout Push Button/Touch

S-039 Power On/Off Switch or Breaker Front Panel

S-040 Remote Control Interface Ethernet IP (Static Config)

S-041 Bit/Byte Decoding for Control/Status To Be Defined by RTT

S-042 VSWR Protection for Source/Load Mismatch No Damage or Oscillation

S-043 TWT Protection in Addition to VSWR Arc,Temp,Over-Volt/Current

S-044 Additional Status and Fault monitoring for: Power Voltages and Currents

S-045 Remote Control of Power On/Off In Addition to Standby/Operate

X Band

S-001 Freq Range (GHz) 12 - 18 (Instantaneous BW)

S-002 Minimum Peak Output Power (Watts) 6 kW @ all frequencies

S-003 Typical Gain @ Rated Power Out (dB) 70

S-004 Minimum Duty Cycle Rating (%) 6%

S-005 Modulation AM/FM/Pulse

S-006 Output Power On/Off Delta (dB) >80

S-007 Pulse Width Range (ns) 50 to 50,000

S-008 Max PRF (kHz) 100

S-009 RF In for Rated Pwr Out (dBm) 0

S-010 RF Droop Across Pulse Width (dB) < 0.5

S-011 RF Pulse to Pulse Stability (dB) 0.1

S-012 Max RF Pulse Overshoot (% of Avg Pwr) 5

S-013 RF In to Out Max Pulse Delay (ns) 500

S-014 RF Pulse to Pulse Phase Stability (°) ±1

S-015 Max RF Output Pulse Rise/Fall Time (ns) 20

S-016 RF Pulse to Pulse Recovery Time (ns) 150

S-017 I/O Impedance (Ω) 50

S-018 I/O VSWR 2.0:1

S-019 Spurious Output w/in 1 MHz (dBc) <-50

S-020 Tx Bkt (Gating) Pulse Input Type 5V TTL

S-021 Tx Bkt Max Pulse to Pulse Jitter (ns) ±5

S-022 Tx Bkt Max Pulse Width Jitter (ns) ±5

S-023 RF Input Sample Coupled Output (dB) 20

S-024 RF Output Sample Coupled Output (dB) 60

S-025 RF Input Connectors N - F

S-026 RF Sample Output Connectors N - F

S-027 RF High Power Output Connector SC - F

S-028 Tx Bkt Input Connector BNC - F

S-029 Connector Location (Pwr,RF,TTL,Ethernet) Rear Panel

S-030 Chassis Form Factor

19" Rack Mount, 30" Deep Max, 40"

Heighth Max

S-031 Chassis Vertical Rack Units Specify RU's (or Inches) in Bid

S-032 Prime Power 208 VAC, 3 Ph, 60 Hz

S-033 Chassis Cooling Type Internal Forced Air

S-034 Operating Temperature Range (°C) -10 to 50

S-035 Operating Altitude (Ft Above Sea Level) 10,000

S-036 Storage Temperature Range (°C) -20 to 70

S-037 Command and Control Methods Local and Remote

S-038 Local Control with Front Panel Readout Push Button/Touch

S-039 Power On/Off Switch or Breaker Front Panel

S-040 Remote Control Interface Ethernet IP (Static Config)

S-041 Bit/Byte Decoding for Control/Status To Be Defined by RTT

S-042 VSWR Protection for Source/Load Mismatch No Damage or Oscillation

S-043 TWT Protection in Addition to VSWR Arc,Temp,Over-Volt/Current

S-044 Additional Status and Fault monitoring for: Power Voltages and Currents

S-045 Remote Control of Power On/Off In Addition to Standby/Operate

Ku Band

File details come from the government source that posted it. Updated .