This requirements document outlines the need for eight traveling wave tube amplifiers and optional spare amplifiers to support the National Radar Cross Section Test Facility Dynamic RCS Measurement System. The Air Force Materiel Command Test Center is seeking two amplifiers each for the S and Ku bands, with pulse widths between 50-50,000 nanoseconds, peak output power of 6 kW, and gain of at least 70 dB. Delivery is required no later than March 31, 2022 for the initial amplifiers and 18 months after option exercise for any spares. The contractor must meet technical and documentation requirements and provide regular status reports, schedule updates, and documentation for acceptance including assembly drawings, training materials, and operations/maintenance manuals.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA9101-20-Q-2019_QnA.pdf | ||
| Atch 01 Rqmt Doc_DRMS TWTAs_Rev 1.pdf | ||
| Atch 02_FAR DFARS AFFARS Prov and Clauses.pdf | ||
| 1 FA9101-20-Q-2019_Combined Synopsis Solicitation.pdf | ||
| Atch 04_Past Perf Quest.docx | DOCX document | |
| Atch 03_Evaluation Plan.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Requirements Document
FOR
National Radar Cross Section Test Facility (NRTF)
Dynamic RCS Measurement System (DRMS)
High Power Amplifier(s)
TABLE OF CONTENTS
1. INTRODUCTION
2. DELIVERY
3. PROJECT SCHEDULE
4. TECHNCAL INTERCHANGE AND ACCEPTANCE
5. REQUIRED DOCUMENTS
6. CONTRACTOR CONTACT INFORMATION
1. INTRODUCTION
The US Air Force, National Radar Cross-Section Test Facility (NRTF) is pursuing a multi-phase development of an S-Ku band Tier IV Dynamic RCS Measurement System (DRMS) at White Sands
NM to augment the current test facility. The DRMS will use dedicated wideband coherent octave traveling wave tube amplifiers (TWTAs) per radar band and per polarization. The Contractor’s shall meet the minimum requirements stated in the Requirements Documents, appendices 1-4.
S-Ku Band DRMS TWTA Specifications TR#001-046
Transmitter Control Ethernet Interface
The Requirements Document and the associated technical appendicies are to provide the requirements to define the TWTAs necessary to meet DRMS requirements. The DRMS system will initially procure a total of eight (8) TWTAs, two (2) per band with the option to purchase four (4) additional spare TWTAs (one (1) per band), as needed, up to a maximum of 12 total TWTAs on this acquisition.
2. DELIVERY
Delivery requirements for the TWTS are as follows:
1. Eight (8) TWTAs: No later than Mar 31, 2022.
2. Option 1 (Date of award to 24 months), Four (4) spare TWTAs: Due no later than 18 months after exercise of the option.
3. PROJECT SCHEDULE
The Contractor shall provide a complete milestone schedule that denotes major activities, demonstrations, and acceptance testing.
4. TECHNCAL INTERCHANGE AND ACCEPTANCE
The contractor shall conduct the following reviews with Government representatives:
Kick-off/ Technical Interchange Meeting (TIM)
Mid-Term Program Management and Progress Meeting
Physical Configuration Audit (PCA)/Factory Acceptance Test (FAT)
Assembly Drawings
Technical Theory, Operation and Maintenance Training and Manuals
These meeting shall be conducted in a format of the Contractor’s choosing and shall cover the overall technical approach, constraints, methods and techniques being examined, performance metrics and results.
5. REQUIRED DOCUMENTS
The Contractor shall provide performance to plan status reports and schedule updates to the AF
Project Manager per the frequency in Table 5-1. All documents are subject to Government acceptance and approval.
Table 5.1 Reporting Requirements
6. CONTRACTOR CONTACT INFORMATION
Upon notice of award, the Contractor shall provide the Contracting Officer and the Government
Project Manager the names and contact information (address, phone number, and email) of a minimum of two (2) Contractor representatives, preferably the contracting agent and project leader.
Any changes in the contact information will immediately be updated by the Contractor as they occur during the duration of this contract and be provided to the Contracting Officer and the
Government Project Manager.
Document Format Frequency
Project Status
Report
MS Word document or email Quarterly
Milestone Schedule MS Project, Word, or Excel file
Updated Quarterly
PCA Results MS Word 30 Days post milestone
FAT Results MS Word 30 days post milestone
Training Docs MS PowerPoint 30 days post milestone
Assembly
Drawings
IGES or STL Compatible 30 days post PCA/FAT
Operations and
Maintenance
Manuals
Word or PDF 30 days post PCA/FAT
Requirements: Specification Description Specification Compliance Pass/Fail
S-001 Freq Range (GHz) 2 - 4 (Instantaneous BW)
S-002 Minimum Peak Output Power (Watts) 6 kW @ all frequencies
S-003 Typical Gain @ Rated Power Out (dB) 70
S-004 Minimum Duty Cycle Rating (%) 6%
S-005 Modulation AM/FM/Pulse
S-006 Output Power On/Off Delta (dB) >80
S-007 Pulse Width Range (ns) 50 to 50,000
S-008 Max PRF (kHz) 100
S-009 RF In for Rated Pwr Out (dBm) 0
S-010 RF Droop Across Pulse Width (dB) < 0.5
S-011 RF Pulse to Pulse Stability (dB) 0.1
S-012 Max RF Pulse Overshoot (% of Avg Pwr) 5
S-013 RF In to Out Max Pulse Delay (ns) 500
S-014 RF Pulse to Pulse Phase Stability (°) ±1
S-015 Max RF Output Pulse Rise/Fall Time (ns) 20
S-016 RF Pulse to Pulse Recovery Time (ns) 150
S-017 I/O Impedance (Ω) 50
S-018 I/O VSWR 2.0:1
S-019 Spurious Output w/in 1 MHz (dBc) <-50
S-020 Tx Bkt (Gating) Pulse Input Type 5V TTL
S-021 Tx Bkt Max Pulse to Pulse Jitter (ns) ±5
S-022 Tx Bkt Max Pulse Width Jitter (ns) ±5
S-023 RF Input Sample Coupled Output (dB) 20
S-024 RF Output Sample Coupled Output (dB) 60
S-025 RF Input Connectors N - F
S-026 RF Sample Output Connectors N - F
S-027 RF High Power Output Connector SC - F
S-028 Tx Bkt Input Connector BNC - F
S-029 Connector Location (Pwr,RF,TTL,Ethernet) Rear Panel
S-030 Chassis Form Factor
19" Rack Mount, 30" Deep Max. 40"
Heigth Max
S-031 Chassis Vertical Rack Units Specify RU's (or Inches) in Bid
S-032 Prime Power 208 VAC, 3 Ph, 60 Hz
S-033 Chassis Cooling Type Internal Forced Air
S-034 Operating Temperature Range (°C) -10 to 50
S-035 Operating Altitude (Ft Above Sea Level) 10,000
S-036 Storage Temperature Range (°C) -20 to 70
S-037 Command and Control Methods Local and Remote
S-038 Local Control with Front Panel Readout Push Button/Touch
S-039 Power On/Off Switch or Breaker Front Panel
S-040 Remote Control Interface Ethernet IP (Static Config)
S-041 Bit/Byte Decoding for Control/Status To Be Defined by RTT
S-042 VSWR Protection for Source/Load Mismatch No Damage or Oscillation
S-043 TWT Protection in Addition to VSWR Arc,Temp,Over-Volt/Current
S-044 Additional Status and Fault monitoring for: Power Voltages and Currents
S-045 Remote Control of Power On/Off In Addition to Standby/Operate
S-046 Power Up BIT Auto w/Results Status
S Band
S-001 Freq Range (GHz) 4 - 8 (Instantaneous BW)
S-002 Minimum Peak Output Power (Watts) 6 kW @ all frequencies
S-003 Typical Gain @ Rated Power Out (dB) 70
S-004 Minimum Duty Cycle Rating (%) 6%
S-005 Modulation AM/FM/Pulse
S-006 Output Power On/Off Delta (dB) >80
S-007 Pulse Width Range (ns) 50 to 50,000
S-008 Max PRF (kHz) 100
S-009 RF In for Rated Pwr Out (dBm) 0
S-010 RF Droop Across Pulse Width (dB) < 0.5
S-011 RF Pulse to Pulse Stability (dB) 0.1
S-012 Max RF Pulse Overshoot (% of Avg Pwr) 5
S-013 RF In to Out Max Pulse Delay (ns) 500
S-014 RF Pulse to Pulse Phase Stability (°) ±1
S-015 Max RF Output Pulse Rise/Fall Time (ns) 20
S-016 RF Pulse to Pulse Recovery Time (ns) 150
S-017 I/O Impedance (Ω) 50
S-018 I/O VSWR 2.0:1
S-019 Spurious Output w/in 1 MHz (dBc) <-50
S-020 Tx Bkt (Gating) Pulse Input Type 5V TTL
S-021 Tx Bkt Max Pulse to Pulse Jitter (ns) ±5
S-022 Tx Bkt Max Pulse Width Jitter (ns) ±5
S-023 RF Input Sample Coupled Output (dB) 20
S-024 RF Output Sample Coupled Output (dB) 60
S-025 RF Input Connectors N - F
S-026 RF Sample Output Connectors N - F
S-027 RF High Power Output Connector SC - F
S-028 Tx Bkt Input Connector BNC - F
S-029 Connector Location (Pwr,RF,TTL,Ethernet) Rear Panel
S-030 Chassis Form Factor
19" Rack Mount, 30" Deep Max, 40"
Heigth Max
S-031 Chassis Vertical Rack Units Specify RU's (or Inches) in Bid
S-032 Prime Power 208 VAC, 3 Ph, 60 Hz
S-033 Chassis Cooling Type Internal Forced Air
S-034 Operating Temperature Range (°C) -10 to 50
S-035 Operating Altitude (Ft Above Sea Level) 10,000
S-036 Storage Temperature Range (°C) -20 to 70
S-037 Command and Control Methods Local and Remote
S-038 Local Control with Front Panel Readout Push Button/Touch
S-039 Power On/Off Switch or Breaker Front Panel
S-040 Remote Control Interface Ethernet IP (Static Config)
S-041 Bit/Byte Decoding for Control/Status To Be Defined by RTT
S-042 VSWR Protection for Source/Load Mismatch No Damage or Oscillation
S-043 TWT Protection in Addition to VSWR Arc,Temp,Over-Volt/Current
S-044 Additional Status and Fault monitoring for: Power Voltages and Currents
S-045 Remote Control of Power On/Off In Addition to Standby/Operate
C Band
S-001 Freq Range (GHz) 8 - 12 (Instantaneous BW)
S-002 Minimum Peak Output Power (Watts) 6 kW @ all frequencies
S-003 Typical Gain @ Rated Power Out (dB) 70
S-004 Minimum Duty Cycle Rating (%) 6%
S-005 Modulation AM/FM/Pulse
S-006 Output Power On/Off Delta (dB) >80
S-007 Pulse Width Range (ns) 50 to 50,000
S-008 Max PRF (kHz) 100
S-009 RF In for Rated Pwr Out (dBm) 0
S-010 RF Droop Across Pulse Width (dB) < 0.5
S-011 RF Pulse to Pulse Stability (dB) 0.1
S-012 Max RF Pulse Overshoot (% of Avg Pwr) 5
S-013 RF In to Out Max Pulse Delay (ns) 500
S-014 RF Pulse to Pulse Phase Stability (°) ±1
S-015 Max RF Output Pulse Rise/Fall Time (ns) 20
S-016 RF Pulse to Pulse Recovery Time (ns) 150
S-017 I/O Impedance (Ω) 50
S-018 I/O VSWR 2.0:1
S-019 Spurious Output w/in 1 MHz (dBc) <-50
S-020 Tx Bkt (Gating) Pulse Input Type 5V TTL
S-021 Tx Bkt Max Pulse to Pulse Jitter (ns) ±5
S-022 Tx Bkt Max Pulse Width Jitter (ns) ±5
S-023 RF Input Sample Coupled Output (dB) 20
S-024 RF Output Sample Coupled Output (dB) 60
S-025 RF Input Connectors N - F
S-026 RF Sample Output Connectors N - F
S-027 RF High Power Output Connector SC - F
S-028 Tx Bkt Input Connector BNC - F
S-029 Connector Location (Pwr,RF,TTL,Ethernet) Rear Panel
S-030 Chassis Form Factor
19" Rack Mount, 30" Deep Max, 40"
Heighth Max
S-031 Chassis Vertical Rack Units Specify RU's (or Inches) in Bid
S-032 Prime Power 208 VAC, 3 Ph, 60 Hz
S-033 Chassis Cooling Type Internal Forced Air
S-034 Operating Temperature Range (°C) -10 to 50
S-035 Operating Altitude (Ft Above Sea Level) 10,000
S-036 Storage Temperature Range (°C) -20 to 70
S-037 Command and Control Methods Local and Remote
S-038 Local Control with Front Panel Readout Push Button/Touch
S-039 Power On/Off Switch or Breaker Front Panel
S-040 Remote Control Interface Ethernet IP (Static Config)
S-041 Bit/Byte Decoding for Control/Status To Be Defined by RTT
S-042 VSWR Protection for Source/Load Mismatch No Damage or Oscillation
S-043 TWT Protection in Addition to VSWR Arc,Temp,Over-Volt/Current
S-044 Additional Status and Fault monitoring for: Power Voltages and Currents
S-045 Remote Control of Power On/Off In Addition to Standby/Operate
X Band
S-001 Freq Range (GHz) 12 - 18 (Instantaneous BW)
S-002 Minimum Peak Output Power (Watts) 6 kW @ all frequencies
S-003 Typical Gain @ Rated Power Out (dB) 70
S-004 Minimum Duty Cycle Rating (%) 6%
S-005 Modulation AM/FM/Pulse
S-006 Output Power On/Off Delta (dB) >80
S-007 Pulse Width Range (ns) 50 to 50,000
S-008 Max PRF (kHz) 100
S-009 RF In for Rated Pwr Out (dBm) 0
S-010 RF Droop Across Pulse Width (dB) < 0.5
S-011 RF Pulse to Pulse Stability (dB) 0.1
S-012 Max RF Pulse Overshoot (% of Avg Pwr) 5
S-013 RF In to Out Max Pulse Delay (ns) 500
S-014 RF Pulse to Pulse Phase Stability (°) ±1
S-015 Max RF Output Pulse Rise/Fall Time (ns) 20
S-016 RF Pulse to Pulse Recovery Time (ns) 150
S-017 I/O Impedance (Ω) 50
S-018 I/O VSWR 2.0:1
S-019 Spurious Output w/in 1 MHz (dBc) <-50
S-020 Tx Bkt (Gating) Pulse Input Type 5V TTL
S-021 Tx Bkt Max Pulse to Pulse Jitter (ns) ±5
S-022 Tx Bkt Max Pulse Width Jitter (ns) ±5
S-023 RF Input Sample Coupled Output (dB) 20
S-024 RF Output Sample Coupled Output (dB) 60
S-025 RF Input Connectors N - F
S-026 RF Sample Output Connectors N - F
S-027 RF High Power Output Connector SC - F
S-028 Tx Bkt Input Connector BNC - F
S-029 Connector Location (Pwr,RF,TTL,Ethernet) Rear Panel
S-030 Chassis Form Factor
19" Rack Mount, 30" Deep Max, 40"
Heighth Max
S-031 Chassis Vertical Rack Units Specify RU's (or Inches) in Bid
S-032 Prime Power 208 VAC, 3 Ph, 60 Hz
S-033 Chassis Cooling Type Internal Forced Air
S-034 Operating Temperature Range (°C) -10 to 50
S-035 Operating Altitude (Ft Above Sea Level) 10,000
S-036 Storage Temperature Range (°C) -20 to 70
S-037 Command and Control Methods Local and Remote
S-038 Local Control with Front Panel Readout Push Button/Touch
S-039 Power On/Off Switch or Breaker Front Panel
S-040 Remote Control Interface Ethernet IP (Static Config)
S-041 Bit/Byte Decoding for Control/Status To Be Defined by RTT
S-042 VSWR Protection for Source/Load Mismatch No Damage or Oscillation
S-043 TWT Protection in Addition to VSWR Arc,Temp,Over-Volt/Current
S-044 Additional Status and Fault monitoring for: Power Voltages and Currents
S-045 Remote Control of Power On/Off In Addition to Standby/Operate
Ku Band