Ames Garage Exterior Wall and Door Replacement Specification

This is a standard material specifications document prepared for the Ames Medical Classification Center garage exterior wall and door replacement project under the Iowa Department of Corrections. The specification establishes comprehensive technical requirements across multiple construction disciplines including cold-formed metal framing, rough carpentry, thermal insulation, metal wall panels, joint sealants, hollow metal doors and frames, door hardware, and glazing. The project involves replacement of the garage's exterior walls and passage doors, requiring formed steel stud exterior wall framing, wood sheathing, mineral fiber blanket insulation, precoated steel metal wall panels in a vertical profile with double-interlocked side seams, thermally insulated hollow metal doors with polyurethane cores achieving an R-value of 8.7 minimum, and safety-glazed door lites. The specification references applicable industry standards including AISI S100, ASTM material standards, ICC International Building Code, BHMA hardware standards, and GANA glazing guidelines, with all work to be performed by manufacturers and installers with minimum three years of documented experience in their respective trades.

The specification requires all materials to comply with current ASTM standards for steel coatings, galvanizing, and corrosion protection, with field quality control inspections mandated for material verification. Exterior doors must include thermally broken door frames with weatherstripping and rain guards, door closers, exit devices, protective plates, and thresholds meeting accessibility standards. Hardware finishes are specified as satin chromium plated over nickel in accordance with BHMA A156.18. The document establishes strict installation tolerances, including vertical stud alignment of 1/960 of span or 1/8 inch in 10 feet, and maximum diagonal distortion of 1/16 inch for door and frame assemblies. Contractor submittals must include product data, shop drawings, manufacturer installation instructions, and warranty documentation, with ten-year manufacturer warranties required for insulating glass units and two-year warranties for sealants. No pricing information, contract value, procurement timeline, or bidding details are contained within this specifications document.

View the file

Other files

File Type Posted
A101-2017 - for RFB 1.pdf PDF
Ames Garage Exterior Wall and Door Replacement Photo.pdf PDF
1409544-event.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

0-Standard Material Specifications - 1219 25-Jun-2026

Page

Cold-Formed Metal Framing 05 4000

SECTION 05 4000

COLD-FORMED METAL FRAMING

PART 1 GENERAL

1.01 SECTION INCLUDES

A. Formed steel stud exterior wall framing.

1.02 RELATED REQUIREMENTS

A. Section 06 1000 - Rough Carpentry: Wall sheathing.

B. Section 07 2100 - Thermal Insulation: Insulation within framing members.

C. Section 07 2500 - Weather Barriers: Water-resistive barrier over sheathing.

1.03 REFERENCE STANDARDS

A. AISI S100 - North American Specification for the Design of Cold-Formed Steel Structural

Members; 2016, with Supplement (2022).

B. ASCE 7 - Minimum Design Loads and Associated Criteria for Buildings and Other Structures;

Most Recent Edition Cited by Referring Code or Reference Standard.

C. ASTM A153/A153M - Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel

Hardware; 2023.

D. ASTM A780/A780M - Standard Practice for Repair of Damaged and Uncoated Areas of Hot-Dip

Galvanized Coatings; 2020.

E. ASTM A1011/A1011M - Standard Specification for Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, and Ultra-High Strength; 2025.

F. ASTM C1007 - Standard Specification for Installation of Load Bearing (Transverse and Axial) Steel Studs and Related Accessories; 2020 (Reapproved 2024).

G. ICC (IBC) - International Building Code; Most Recent Edition Adopted by Authority Having Jurisdiction, Including All Applicable Amendments and Supplements.

H. SSPC-Paint 20 - Zinc-Rich Coating (Type I - Inorganic, and Type II - Organic); 2019.

1.04 SUBMITTALS

A. See Section 01 3000 - Administrative Requirements for submittal procedures.

B. Product Data: Provide data on standard framing members; describe materials and finish, product criteria, limitations.

1.05 QUALITY ASSURANCE

A. Designer Qualifications: Design framing system under direct supervision of a professional structural engineer experienced in designing this work and licensed in the State in which the Project is located.

B. Installer Qualifications: Company specializing in performing the work of this section with minimum three years documented experience and approved by manufacturer.

PART 2 PRODUCTS

2.01 PERFORMANCE REQUIREMENTS

A. Design Requirements: Design cold-formed framing systems, components and connectors to withstand specified design loads in compliance with ICC (IBC), ASCE 7, AISI S100, and AISI S240.

2.02 MATERIALS

A. Steel Sheet: ASTM A1003/A1003M, subject to the ductility limitations indicated in AISI S240.

asmelse Rectangle

Page

Cold-Formed Metal Framing 05 4000

2.03 STRUCTURAL FRAMING COMPONENTS

A. Wall Studs and Track Sections: AISI S240; c-shaped studs and u-shaped track sections in stud-matching nominal width and compatible height.

1. Structural Grade: As required to meet design criteria.

B. Headers: AISI S240; manufactured, engineered one-member or two-member assemblies, with wide flanges, designed to replace conventional box or nested header framing at openings.

1. Jamb Mounting Clips: Manufacturer's standard.

2.04 MISCELLANEOUS CONNECTIONS

A. Self-Drilling, Self-Tapping Screws, Bolts, Nuts and Washers: Hot-dip galvanized per ASTM

A153/A153M.

2.05 ACCESSORIES

A. Galvanizing Repair: Touch up bare steel with zinc-rich paint in compliance with ASTM A780/A780M.

B. Touch-Up Primer for Galvanized Surfaces: SSPC-Paint 20 Type I - Inorganic, complying with VOC limitations of authorities having jurisdiction.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verify that substrate surfaces are ready to receive work.

3.02 INSTALLATION - GENERAL

A. Install structural members and connections in compliance with ASTM C1007.

3.03 INSTALLATION OF STUDS

A. Install wall studs plumb and level.

B. Install load-bearing studs full length in one piece. Splicing of studs is not permitted.

C. Provide deflection allowance in stud track, directly below horizontal building framing at non-loadbearing framing.

D. Touch-up field welds and damaged corrosion-protected surfaces zinc-rich paint in compliance with ASTM A780/A780M.

E. Touch-up field welds and damaged corrosion protected surfaces with primer.

3.04 FIELD QUALITY CONTROL

A. See Section 01 4000 - Quality Requirements, for additional requirements.

B. Provide material verification inspections in accordance with requirements of AISI S240.

3.05 TOLERANCES

A. Studs - Vertical Alignment (Plumbness): 1/960 of span or 1/8 inch in 10 ft, in accordance with

ASTM C1007.

END OF SECTION

Page

Rough Carpentry 06 1000

SECTION 06 1000

ROUGH CARPENTRY

PART 1 GENERAL

1.01 SECTION INCLUDES

A. Rough opening framing for doors, windows, and roof openings.

B. Sheathing.

C. Concealed wood blocking, nailers, and supports.

D. Miscellaneous wood nailers, furring, and grounds.

1.02 RELATED REQUIREMENTS

A. Section 07 2500 - Weather Barriers: Water-resistive barrier over sheathing.

B. Section 07 6200 - Sheet Metal Flashing and Trim: Sill flashings.

1.03 REFERENCE STANDARDS

A. ANSI A208.1 - American National Standard for Particleboard; 2022.

B. ASTM A153/A153M - Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel

Hardware; 2023.

C. ASTM D3498 - Standard Specification for Adhesives for Field-Gluing Wood Structural Panels

(Plywood or Oriented Strand Board) to Wood Based Floor System Framing; 2019a.

D. ASTM E84 - Standard Test Method for Surface Burning Characteristics of Building Materials;

2026a.

E. AWPA U1 - Use Category System: User Specification for Treated Wood; 2025.

F. ICC-ES AC38 - Acceptance Criteria for Water-Resistive Barriers; 2016, with Editorial Revision

(2021).

G. PS 1 - Structural Plywood; 2023.

H. PS 2 - Performance Standard for Wood Structural Panels; 2019.

I. PS 20 - American Softwood Lumber Standard; 2025.

J. SPIB (GR) - Standard Grading Rules; 2021.

K. WWPA G-5 - Western Lumber Grading Rules; 2025.

1.04 SUBMITTALS

A. See Section 01 3000 - Administrative Requirements for submittal procedures.

B. Product Data: Provide technical data on insulated sheathing and application instructions.

C. Warranty Documentation: Submit manufacturer warranty and ensure that forms have been completed in Owner's name and registered with manufacturer.

1.05 DELIVERY, STORAGE, AND HANDLING

A. General: Cover wood products to protect against moisture. Support stacked products to prevent deformation and to allow air circulation.

PART 2 PRODUCTS

2.01 GENERAL REQUIREMENTS

A. Dimension Lumber: Comply with PS 20 and requirements of specified grading agencies.

1. Species: Douglas Fir-Larch, unless otherwise indicated.

2. If no species is specified, provide species graded by the agency specified; if no grading agency is specified, provide lumber graded by grading agency meeting the specified requirements.

3. Grading Agency: Grading agency whose rules are approved by the Board of Review, American Lumber Standard Committee at www.alsc.org, and who provides grading

Page

Rough Carpentry 06 1000 service for the species and grade specified; provide lumber stamped with grade mark unless otherwise indicated.

4. Lumber of other species or grades is acceptable provided structural and appearance characteristics are equivalent to or better than products specified.

B. Provide sustainably harvested wood; see Section 01 6000 - Product Requirements for requirements.

2.02 DIMENSION LUMBER FOR CONCEALED APPLICATIONS

A. Grading Agency: Southern Pine Inspection Bureau, Inc; SPIB (GR).

B. Sizes: Nominal sizes as indicated on drawings, S4S.

C. Moisture Content: S-dry or MC19.

D. Stud Framing (2 by 2 through 2 by 6 ):

1. Grade: No. 2.

E. Miscellaneous Framing, Blocking, Nailers, Grounds, and Furring:

1. Lumber: S4S, No. 2 or Standard Grade.

2. Boards: Standard or No. 3.

2.03 CONSTRUCTION PANELS

A. Wall Sheathing: Plywood, PS 1, Grade C-D, Exposure I.

B. Wall Sheathing: Oriented strand board wood structural panel; PS 2.

1. Grade: Structural 1 Sheathing.

2. Bond Classification: Exposure 1.

3. Performance Category:

4. Span Rating:

5. Edges: Square.

2.04 ACCESSORIES

A. Metal and Finish of Fasteners:

1. Untreated Wood: Unfinished steel.

B. Die-Stamped Connectors: Hot dipped galvanized steel, sized to suit framing conditions.

C. Subfloor Adhesives: Gap-filling construction adhesive for bonding wood structural panels to wood-based floor system framing; complying with ASTM D3498.

PART 3 EXECUTION

3.01 INSTALLATION - GENERAL

A. Select material sizes to minimize waste.

B. Reuse scrap to the greatest extent possible; clearly separate scrap for use on site as accessory components, including: shims, bracing, and blocking.

3.02 INSTALLATION OF CONSTRUCTION PANELS

A. Subflooring/Underlayment Combination: Glue and nail to framing; staples are not permitted.

B. Wall Sheathing: Secure with long dimension perpendicular to wall studs, with ends over firm bearing and staggered, using nails, screws, or staples.

1. Install plywood wall sheathing in accordance with manufacturer's current ICC-ES evaluation report for specified sheathing product.

3.03 TOLERANCES

A. Framing Members: 1/4 inch from true position, maximum.

B. Variation from Plane, Other than Floors: 1/4 inch in 10 feet maximum, and 1/4 inch in 30 feet maximum.

Page

Rough Carpentry 06 1000

3.04 CLEANING

A. Do not leave wood, shavings, sawdust, etc. on the ground or buried in fill.

B. Prevent sawdust and wood shavings from entering the storm drainage system.

END OF SECTION

Page

Thermal Insulation 07 2100

SECTION 07 2100

THERMAL INSULATION

PART 1 GENERAL

1.01 SECTION INCLUDES

A. Batt insulation in exterior wall construction.

B. Batt insulation for filling perimeter window and door shim spaces.

1.02 REFERENCE STANDARDS

A. ASTM C553 - Standard Specification for Mineral Fiber Blanket Thermal Insulation for

Commercial and Industrial Applications; 2024.

B. ASTM C665 - Standard Specification for Mineral-Fiber Blanket Thermal Insulation for Light

Frame Construction and Manufactured Housing; 2024.

C. ASTM E84 - Standard Test Method for Surface Burning Characteristics of Building Materials;

2026a.

D. ASTM E136 - Standard Test Method for Assessing Combustibility of Materials Using a Vertical

Tube Furnace at 750 Degrees C; 2026.

1.03 SUBMITTALS

A. Product Data: Provide data on product characteristics, performance criteria, and product limitations.

1.04 FIELD CONDITIONS

A. Do not install insulation adhesives when temperature or weather conditions are detrimental to successful installation.

PART 2 PRODUCTS

2.01 APPLICATIONS

A. Insulation in Metal Framed Walls: Batt insulation with no vapor retarder.

2.02 MINERAL FIBER BLANKET INSULATION MATERIALS

A. Flexible Glass Fiber Blanket Thermal Insulation: Preformed insulation, complying with ASTM C665; friction fit.

1. Flame Spread Index: 75 or less, when tested in accordance with ASTM E84.

2. Smoke Developed Index: 450 or less, when tested in accordance with ASTM E84.

3. Combustibility: Non-combustible, when tested in accordance with ASTM E136, except for facing, if any.

2.03 ACCESSORIES

A. Sill Plate Sealer: Closed-cell foam tape with rubberized adhesive membrane; bridges gap between foundation structure and sill plate or skirt board.

1. Width: 3-1/2 inches.

2. Ultraviolet (UV) and Weathering Resistance: Approved in writing by manufacturer for up to 30 days of weather exposure.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verify that substrate, adjacent materials, and insulation materials are dry and that substrates are ready to receive insulation.

B. Verify substrate surfaces are flat, free of honeycomb, fins, irregularities, or materials or substances that may impede adhesive bond.

3.02 BATT INSTALLATION

A. Install insulation and vapor retarder in accordance with manufacturer's instructions.

Page

Thermal Insulation 07 2100

B. Install in exterior wall and roof spaces without gaps or voids. Do not compress insulation.

C. Trim insulation neatly to fit spaces. Insulate miscellaneous gaps and voids.

D. Fit insulation tightly in cavities and tightly to exterior side of mechanical and electrical services within the plane of the insulation.

END OF SECTION

Page

Metal Wall Panels 07 4213

SECTION 07 4213

METAL WALL PANELS

PART 1 GENERAL

1.01 SECTION INCLUDES

A. Manufactured metal panels for exterior wall panels, with related flashings and accessory components.

1.02 RELATED REQUIREMENTS

A. Section 05 4000 - Cold-Formed Metal Framing: Wall panel substrate.

B. Section 07 2100 - Thermal Insulation.

1.03 REFERENCE STANDARDS

A. ASTM A792/A792M - Standard Specification for Steel Sheet, 55% Aluminum-Zinc Alloy-Coated by the Hot-Dip Process; 2021.

B. ASTM E84 - Standard Test Method for Surface Burning Characteristics of Building Materials;

2026a.

C. NFPA 285 - Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of

Exterior Wall Assemblies Containing Combustible Components; 2025.

1.04 SUBMITTALS

A. See Section 01 3000 - Administrative Requirements for submittal procedures.

B. Product Data - Wall System: Manufacturer's data sheets on each product to be used, including:

1. Physical characteristics of components shown on shop drawings.

2. Storage and handling requirements and recommendations.

3. Installation instructions and recommendations.

1.05 DELIVERY, STORAGE, AND HANDLING

A. Protect panels from accelerated weathering by removing or venting sheet plastic shipping wrap.

B. Store prefinished material off the ground and protected from weather; prevent twisting, bending, or abrasion; provide ventilation; slope metal sheets to ensure proper drainage.

C. Prevent contact with materials that may cause discoloration or staining of products.

1.06 FIELD CONDITIONS

A. Do not install wall panels when air temperature or relative humidity are outside manufacturer's limits.

PART 2 PRODUCTS

2.01 METAL WALL PANEL SYSTEM

A. Wall Panel System: Factory fabricated prefinished metal panel system, site assembled.

1. Provide exterior wall panels.

2. Design and size components to support assembly dead loads, and to withstand live loads caused by positive and negative wind pressure acting normal to plane of wall.

3. Maximum Allowable Deflection of Panel: L/180 for length(L) of span.

4. Movement: Accommodate movement within system without damage to components or deterioration of seals, movement between system and perimeter components when subject to seasonal temperature cycling; dynamic loading and release of loads; and deflection of structural support framing.

5. Drainage: Provide positive drainage to exterior for moisture entering or condensation occurring within panel system.

6. Fabrication: Formed true to shape, accurate in size, square, and free from distortion or defects; pieces of longest practical lengths.

7. Corners: Factory-fabricated in one continuous piece with minimum 2-inch returns.

Page

Metal Wall Panels 07 4213

B. Exterior Wall Panels:

1. Profile: Vertical; style as indicated.

2. Side Seams: Double-interlocked, tight-fitting, sealed with continuous gaskets.

3. Material: Precoated steel sheet, 22 gauge, 0.0299 inch minimum thickness.

4. Color: As selected by Architect from manufacturer's standard line.

C. Internal and External Corners: Same material, thickness, and finish as exterior sheets; profile to suit system; shop cut and factory mitered to required angles.

D. Trim: Same material, thickness and finish as exterior sheets; brake formed to required profiles.

E. Anchors: Galvanized steel.

2.02 ACCESSORIES

A. Support for Cladding and Continuous Insulation: Thermal clips.

1. Thermally-broken clips that provide attachment support for girts, angles, channels, and other cladding support framing.

2. Fasteners: As recommended by clip manufacturer.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verify that building framing members are ready to receive panels.

3.02 INSTALLATION

A. Install panels on walls and soffits in accordance with manufacturer's instructions.

3.03 TOLERANCES

3.04 CLEANING

A. Remove site cuttings from finish surfaces.

B. Remove protective material from wall panel surfaces.

END OF SECTION

Page

Joint Sealants 07 9200

SECTION 07 9200

JOINT SEALANTS

PART 1 GENERAL

1.01 SECTION INCLUDES

A. Nonsag gunnable joint sealants.

B. Joint backings and accessories.

1.02 REFERENCE STANDARDS

A. ASTM C661 - Standard Test Method for Indentation Hardness of Elastomeric-Type Sealants by

Means of a Durometer; 2015 (Reapproved 2022).

B. ASTM C834 - Standard Specification for Latex Sealants; 2017 (Reapproved 2023).

C. ASTM C919 - Standard Practice for Use of Sealants in Acoustical Applications; 2024.

D. ASTM C920 - Standard Specification for Elastomeric Joint Sealants; 2018 (Reapproved 2024).

E. ASTM C1193 - Standard Guide for Use of Joint Sealants; 2025.

F. ASTM C1248 - Standard Test Method for Staining of Porous Substrate by Joint Sealants; 2022.

G. ASTM C1330 - Standard Specification for Cylindrical Sealant Backing for Use with Cold Liquid-

Applied Sealants; 2023.

H. ASTM D695 - Standard Test Method for Compressive Properties of Rigid Plastics; 2026.

I. SCAQMD 1168 - Adhesive and Sealant Applications; 1989, with Amendment (2022).

1.03 SUBMITTALS

A. Product Data: Submit manufacturer's technical datasheets for each product to be used; include the following:

1. Physical characteristics, including movement capability, VOC content, hardness, cure time, and color availability.

2. List of backing materials approved for use with the specific product.

3. Substrates that product is known to satisfactorily adhere to and with which it is compatible.

4. Substrates the product should not be used on.

5. Substrates for which use of primer is required.

6. Installation instructions, including precautions, limitations, and recommended backing materials and tools.

B. Color Cards for Selection: Where sealant color is not specified, submit manufacturer's color cards showing standard colors available for selection.

C. Executed warranty.

1.04 QUALITY ASSURANCE

A. Manufacturer Qualifications: Company specializing in manufacturing the products specified in this section with minimum three years documented experience.

B. Installer Qualifications: Company specializing in performing the work of this section and with at least three years of documented experience.

1.05 WARRANTY

A. Manufacturer Warranty: Provide 2-year manufacturer warranty for installed sealants and accessories that fail to achieve a watertight seal, exhibit loss of adhesion or cohesion, or do not cure. Complete forms in Owner's name and register with manufacturer.

B. Extended Correction Period: Correct defective work within 2-year period commencing on Date of Substantial Completion.

Page

Joint Sealants 07 9200

PART 2 PRODUCTS

2.01 JOINT SEALANT APPLICATIONS

A. Scope:

1. Exterior Joints:

a. Seal the following joints:

1) Joints between doors, windows, and other frames or adjacent construction.

B. Type Ext-1 - Exterior Joints: Use non-sag non-staining silicone sealant, unless otherwise indicated.

1. Lap Joints in Sheet Metal Fabrications: Butyl rubber, noncuring.

2.02 NONSAG JOINT SEALANTS

A. Nonstaining Silicone Sealant: ASTM C920, Grade NS, Uses M and A; not expected to withstand continuous water immersion or traffic.

1. Movement Capability: Plus and minus ____ percent, minimum.

2. Nonstaining to Porous Stone: Nonstaining to light-colored natural stone when tested in accordance with ASTM C1248.

3. Dirt Pick-Up: Reduced dirt pick-up compared to other silicone sealants.

4. Hardness Range: 15 to 35, Shore A, when tested in accordance with ASTM C661.

5. Color: Match adjacent finished surfaces.

6. Service Temperature Range: Minus 20 to 180 degrees F.

2.03 ACCESSORIES

A. Sealant Backing Rod, Closed-Cell Type:

1. Cylindrical flexible sealant backings complying with ASTM C1330 Type C.

2. Size: 25 to 50 percent larger in diameter than joint width.

B. Masking Tape: Self-adhesive, nonabsorbent, nonstaining, removable without adhesive residue, and compatible with surfaces adjacent to joints and sealants.

C. Joint Cleaner: Noncorrosive and nonstaining type, type recommended by sealant manufacturer; compatible with joint forming materials.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verify that joints are ready to receive work.

B. Verify that backing materials are compatible with sealants.

C. Verify that backer rods are of the correct size.

3.02 PREPARATION

A. Remove loose materials and foreign matter that could impair adhesion of sealant.

B. Clean joints, and prime as necessary, in accordance with manufacturer's instructions.

C. Perform preparation in accordance with manufacturer's instructions and ASTM C1193.

D. Mask elements and surfaces adjacent to joints from damage and disfigurement due to sealant work; be aware that sealant drips and smears may not be completely removable.

3.03 INSTALLATION

A. Install this work in accordance with sealant manufacturer's requirements for preparation of surfaces and material installation instructions.

B. Provide joint sealant installations complying with ASTM C1193.

C. Measure joint dimensions and size joint backers to achieve width-to-depth ratio, neck dimension, and surface bond area as recommended by manufacturer.

D. Install bond breaker backing tape where backer rod cannot be used.

Page

Joint Sealants 07 9200

E. Install sealant free of air pockets, foreign embedded matter, ridges, and sags, and without getting sealant on adjacent surfaces.

F. Do not install sealant when ambient temperature is outside manufacturer's recommended temperature range, or will be outside that range during the entire curing period, unless manufacturer's approval is obtained and instructions are followed.

G. Nonsag Sealants: Tool surface concave, unless otherwise indicated; remove masking tape immediately after tooling sealant surface.

H. Concrete Floor Joint Filler: After full cure, shave joint filler flush with top of concrete slab.

3.04 FIELD QUALITY CONTROL

A. Remove and replace failed portions of sealants using same materials and procedures as indicated for original installation.

END OF SECTION

Page

Hollow Metal Doors And Frames 08 1113

SECTION 08 1113

HOLLOW METAL DOORS AND FRAMES

PART 1 GENERAL

1.01 SECTION INCLUDES

A. Non-fire-rated hollow metal doors and frames.

B. Thermally insulated hollow metal doors.

1.02 ABBREVIATIONS AND ACRONYMS

A. ANSI: American National Standards Institute.

B. HMMA: Hollow Metal Manufacturers Association.

C. NFPA: National Fire Protection Association.

D. SDI: Steel Door Institute.

E. UL: Underwriters Laboratories.

1.03 REFERENCE STANDARDS

A. ADA Standards - 2010 ADA Standards for Accessible Design; 2010.

B. ANSI/SDI A250.3 - Test Procedure and Acceptance Criteria for Factory Applied Finish Coatings for Steel Doors and Frames; 2025.

C. ANSI/SDI A250.4 - Test Procedure and Acceptance Criteria for Physical Endurance for Steel

Doors, Frames and Frame Anchors; 2026.

D. ANSI/SDI A250.8 - Specifications for Standard Steel Doors and Frames (SDI-100); 2023.

E. ANSI/SDI A250.10 - Test Procedure and Acceptance Criteria for Prime Painted Steel Surfaces for Steel Doors and Frames; 2025.

F. ASTM A653/A653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-

Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process; 2025a.

G. ASTM A1008/A1008M - Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, Required Hardness, Solution Hardened, and Bake Hardenable; 2026.

H. ASTM A1011/A1011M - Standard Specification for Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, and Ultra-High Strength; 2025.

I. BHMA A156.115 - Hardware Preparation in Steel Doors and Frames; 2016.

J. ICC A117.1 - Accessible and Usable Buildings and Facilities; 2017.

K. NAAMM HMMA 830 - Hardware Selection for Hollow Metal Doors and Frames; 2002.

L. NAAMM HMMA 831 - Hardware Locations for Hollow Metal Doors and Frames; 2024.

M. NAAMM HMMA 840 - Guide Specifications for Receipt, Storage and Installation of Hollow Metal

Doors and Frames; 2024.

N. NAAMM HMMA 861 - Guide Specifications for Commercial Hollow Metal Doors and Frames;

2014.

O. SDI 117 - Manufacturing Tolerances for Standard Steel Doors and Frames; 2023.

1.04 SUBMITTALS

A. Product Data: Materials and details of design and construction, hardware locations, reinforcement type and locations, anchorage and fastening methods, and finishes.

B. Shop Drawings: Details of each opening, showing elevations, glazing, frame profiles, and any indicated finish requirements.

Page

Hollow Metal Doors And Frames 08 1113

C. Color selection chart ( provide 1 original paper copy and 1 PDF copy), showing factory finishes, colors, and surface texture.

D. Installation Instructions: Manufacturer's published instructions, including any special installation instructions relating to this project.

1.05 QUALITY ASSURANCE

A. Manufacturer Qualifications: Provide hollow metal doors and frames from SDI Certified manufacturer: https://steeldoor.org/sdi-certified/#sle.

B. Installer Qualifications: Company specializing in performing work of the type specified and with at least three years of documented experience.

C. Maintain at project site copies of reference standards relating to installation of products specified.

1.06 DELIVERY, STORAGE, AND HANDLING

A. Comply with NAAMM HMMA 840 or ANSI/SDI A250.8 (SDI-100) in accordance with specified requirements.

B. Protect with resilient packaging; avoid humidity build-up under coverings; prevent corrosion and adverse effects on factory applied painted finish.

PART 2 PRODUCTS

2.01 PERFORMANCE REQUIREMENTS

A. Requirements for Hollow Metal Doors and Frames:

1. Steel Sheet: Comply with one or more of the following requirements; galvannealed steel complying with ASTM A653/A653M, cold-rolled steel complying with ASTM A1008/A1008M, or hot-rolled pickled and oiled (HRPO) steel complying with ASTM A1011/A1011M, commercial steel (CS) Type B, for each.

2. Accessibility: Comply with ICC A117.1 and ADA Standards.

3. Door Top Closures: Flush end closure channel, with top and door faces aligned.

4. Door Edge Profile: Manufacturers standard for application indicated.

5. Typical Door Face Sheets: Flush.

6. Glazed Lights: Non-removable stops on non-secure side; sizes and configurations as indicated on drawings. Style: Manufacturer's standard.

7. Hardware Preparations, Selections and Locations: Comply with NAAMM HMMA 830 and

NAAMM HMMA 831 or BHMA A156.115 and ANSI/SDI A250.8 (SDI-100) in accordance with specified requirements.

8. Zinc Coating for Typical Interior and/or Exterior Locations: Provide metal components zinc-coated (galvanized) and/or zinc-iron alloy-coated (galvannealed) by the hot-dip process in accordance with ASTM A653/A653M, with manufacturer's standard coating thickness, unless noted otherwise for specific hollow metal doors and frames.

a. Based on SDI Standards: Provide at least A40/ZF120 (galvannealed) when necessary, coating not required for typical interior door applications, and at least A60/ZF180 (galvannealed) for corrosive locations.

B. Combined Requirements: If a particular door and frame unit is indicated to comply with more than one type of requirement, comply with the specified requirements for each type; for instance, an exterior door that is also indicated as being sound-rated must comply with the requirements specified for exterior doors and for sound-rated doors; where two requirements conflict, comply with the most stringent.

2.02 HOLLOW METAL DOORS

A. Exterior Doors including interior garage bay openings: Thermally insulated.

1. Based on SDI Standards: ANSI/SDI A250.8 (SDI-100).

a. Level 1 - Standard-duty.

b. Physical Performance Level C, 250,000 cycles; in accordance with ANSI/SDI A250.4.

c. Model 1 - Full Flush.

Page

Hollow Metal Doors And Frames 08 1113

d. Door Face Metal Thickness: 20 gauge, 0.032 inch, minimum.

e. Zinc Coating: A60/ZF180 galvannealed coating; ASTM A653/A653M.

2. Door Core Material: Polyurethane, 1.8 lbs/cu ft minimum density.

3. Door Thermal Resistance: R-Value of 8.7, minimum, for installed thickness of polyurethane.

4. Door Thickness: 1-3/4 inches, nominal.

5. Weatherstripping: See Section 08 7100.

2.03 HOLLOW METAL FRAMES

A. Comply with standards and/or custom guidelines as indicated for corresponding door in accordance with applicable door frame requirements.

B. Exterior Door Frames: Full profile/continuously welded type.

1. Galvanizing: Components hot-dipped zinc-iron alloy-coated (galvannealed) in accordance with ASTM A653/A653M, with A40/ZF120 coating.

2. Frame Metal Thickness: 16 gage, 0.053 inch, minimum.

3. Frame Finish: Factory finished.

4. Weatherstripping: Separate, see Section 08 7100.

5. Thermal break: NFRC 102, U-Value of 0.36.

2.04 FINISHES

A. Primer: Rust-inhibiting, complying with ANSI/SDI A250.10.

B. Factory Finish: Complying with ANSI/SDI A250.3, manufacturer's standard coating.

1. Color: As selected by Architect from manufacturer's standard range.

2.05 ACCESSORIES

A. Glazing: As specified in Section 08 8000, factory installed.

B. Silencers: Resilient rubber, fitted into drilled hole; provide three on strike side of single door, three on center mullion of pairs, and two on head of pairs without center mullions.

C. Temporary Frame Spreaders: Provide for factory- or shop-assembled frames.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verify existing conditions before starting work.

B. Verify that opening sizes and tolerances are acceptable.

C. Verify that finished walls are in plane to ensure proper door alignment.

3.02 PREPARATION

A. Coat inside of frames to be installed in masonry or to be grouted, with bituminous coating, prior to installation.

3.03 INSTALLATION

A. Install doors and frames in accordance with manufacturer's instructions and related requirements of specified door and frame standards or custom guidelines indicated.

B. Coordinate frame anchor placement with wall construction.

C. Comply with glazing installation requirements of Section 08 8000.

D. Touch up damaged factory finishes.

3.04 TOLERANCES

A. Clearances Between Door and Frame: Comply with related requirements of specified frame standards or custom guidelines indicated in accordance with SDI 117 or NAAMM HMMA 861.

B. Maximum Diagonal Distortion: 1/16 inch measured with straight edge, corner to corner.

Page

Hollow Metal Doors And Frames 08 1113

3.05 ADJUSTING

A. Adjust for smooth and balanced door movement.

B. Adjust sound control doors so that seals are fully engaged when door is closed.

END OF SECTION

Page

Door Hardware 08 7100

SECTION 08 7100

DOOR HARDWARE

PART 1 GENERAL

1.01 SECTION INCLUDES

A. Hardware for hollow metal doors.

B. Thresholds.

C. Weatherstripping and gasketing.

1.02 RELATED REQUIREMENTS

A. Section 08 1113 - Hollow Metal Doors and Frames.

1.03 REFERENCE STANDARDS

A. ADA Standards - 2010 ADA Standards for Accessible Design; 2010.

B. BHMA A156.1 - Standard for Butts and Hinges; 2025.

C. BHMA A156.3 - Exit Devices; 2025.

D. BHMA A156.4 - Door Closers and Pivots; 2024.

E. BHMA A156.5 - Cylinders and Input Devices for Locks; 2020.

F. BHMA A156.6 - Standard for Architectural Door Trim; 2021.

G. BHMA A156.7 - Template Hinge Dimensions; 2022.

H. BHMA A156.8 - Door Controls - Overhead Stops and Holders; 2021.

I. BHMA A156.15 - Release Devices - Closer Holder, Electromagnetic and Electromechanical;

2021.

J. BHMA A156.18 - Standard for Materials and Finishes; 2020.

K. BHMA A156.21 - Thresholds; 2025.

L. BHMA A156.22 - Standard for Gasketing; 2021.

M. BHMA A156.31 - Electric Strikes and Frame Mounted Actuators; 2024.

N. BHMA A156.115 - Hardware Preparation in Steel Doors and Frames; 2016.

O. ICC A117.1 - Accessible and Usable Buildings and Facilities; 2017.

P. NFPA 101 - Life Safety Code; Most Recent Edition Adopted by Authority Having Jurisdiction, Including All Applicable Amendments and Supplements.

Q. UL 437 - Standard for Key Locks; Current Edition, Including All Revisions.

1.04 ADMINISTRATIVE REQUIREMENTS

A. Coordinate the manufacture, fabrication, and installation of products that door hardware is installed on.

B. Furnish templates for door and frame preparation to manufacturers and fabricators of products requiring internal reinforcement for door hardware.

1.05 SUBMITTALS

A. Product Data: Manufacturer's catalog literature for each type of hardware, marked to clearly show products to be furnished for this project, and includes construction details, material descriptions, finishes, and dimensions and profiles of individual components.

B. Shop Drawings - Door Hardware Schedule: Submit detailed listing that includes each item of hardware to be installed on each door. Use door numbering scheme as included in Contract Documents.

1. Prepared by or under supervision of Architectural Hardware Consultant (AHC).

2. List groups and suffixes in proper sequence.

3. Provide complete description for each door listed.

Page

Door Hardware 08 7100

4. Provide manufacturer name, product names, and catalog numbers; include functions, types, styles, sizes and finishes of each item.

5. Include account of abbreviations and symbols used in schedule.

C. Maintenance Data: Include data on operating hardware, lubrication requirements, and inspection procedures related to preventative maintenance.

D. Project Record Documents: Record actual locations of concealed equipment, services, and conduit.

E. Maintenance Materials and Tools: Furnish the following for Owner's use in maintenance of project.

1. Lock Cylinders: Ten for each master keyed group.

2. Tools: One set of each special wrench or tool applicable for each different or special hardware component, whether supplied by hardware component manufacturer or not.

1.06 QUALITY ASSURANCE

A. Manufacturer Qualifications: Company specializing in manufacturing products specified in this section with minimum three years of documented experience.

B. Supplier Qualifications: Company with certified Architectural Hardware Consultant (AHC) to assist in work of this section.

1.07 DELIVERY, STORAGE, AND HANDLING

A. Package hardware items individually; label and identify each package with door opening code to match door hardware schedule.

1.08 WARRANTY

A. Manufacturer's Warranty: Provide warranty against defects in material and workmanship for period indicated. Complete forms in Owner's name and register with manufacturer.

1. Closers: Five years, minimum.

2. Exit Devices: Three years, minimum.

3. Locksets and Cylinders: Three years, minimum.

4. Other Hardware: Two years, minimum.

PART 2 PRODUCTS

2.01 DESIGN AND PERFORMANCE CRITERIA

A. Provide specified door hardware as required to make doors fully functional, compliant with applicable codes, and secure to extent indicated.

B. Provide individual items of single type, of same model, and by same manufacturer.

C. Provide door hardware products that comply with the following requirements:

1. Applicable provisions of federal, state, and local codes.

2. Accessibility: ADA Standards and ICC A117.1.

3. Hardware Preparation for Steel Doors and Steel Frames: BHMA A156.115.

2.02 HINGES

A. Hinges: Comply with BHMA A156.1, Grade 1.

1. Butt Hinges: Comply with BHMA A156.1 and BHMA A156.7 for templated hinges.

a. Provide hinge width required to clear surrounding trim.

2. Provide hinges on every swinging door.

3. Provide five-knuckle full mortise butt hinges unless otherwise indicated.

4. Provide ball-bearing hinges at each door with closer.

5. Provide non-removable pins on exterior outswinging doors.

6. Provide non-removable pins on interior outswinging doors at locations as indicated.

7. Provide power transfer hinges where electrified hardware is mounted in door leaf.

8. Provide following quantity of butt hinges for each door:

a. Doors up to 60 inches High: Two hinges.

Page

Door Hardware 08 7100

b. Doors From 60 inches High up to 90 inches High: Three hinges.

c. Doors 90 inches High up to 120 inches High: Four hinges.

2.03 EXIT DEVICES

A. Manufacturers:

B. Exit Devices: Comply with BHMA A156.3, Grade 1.

1. Lever design to match lockset trim.

2. Provide cylinder with cylinder dogging or locking trim.

3. Provide exit devices properly sized for door width and height.

4. Provide strike as recommended by manufacturer for application indicated.

5. Provide UL (DIR) listed exit device assemblies for fire-rated doors and panic device assemblies for non-fire-rated doors

6. .Grooved case.

2.04 LOCK CYLINDERS

A. Lock Cylinders: Provide key access on outside of each lock, unless otherwise indicated.

1. Provide cylinders from same manufacturer as locking device.

2. Provide cams and/or tailpieces as required for locking devices.

2.05 CLOSERS

A. Manufacturers; Surface Mounted:

B. Closers: Comply with BHMA A156.4, Grade 1.

1. Type: Surface mounted to door.

2. Provide door closer on each exterior door.

3. At corridor entry doors, mount closer on room side of door.

4. At outswinging exterior doors, mount closer on interior side of door.

2.06 PROTECTION PLATES

A. Protection Plates: Comply with BHMA A156.6.

B. Metal Properties: Stainless steel.

C. Edges: Beveled, on four sides unless otherwise indicated.

D. Fasteners: Countersunk screw fasteners.

E. Drip Guard: Provide at head of exterior doors unless covered by roof or canopy.

2.07 KICK PLATES

A. Kick Plates: Provide along bottom edge of push side of every door with closer, except aluminum storefront and glass entry doors, unless otherwise indicated.

1. Size: 12 inch high by 2 inch less door width (LDW) on push side of door.

2.08 THRESHOLDS

A. Thresholds: Comply with BHMA A156.21.

1. Provide threshold at interior doors for transition between two different floor types, and at openings from garage spaces to interior spaces at office area., unless otherwise indicated.

2. Provide threshold at each exterior door, unless otherwise indicated.

3. Type: Flat surface.

4. Material: Aluminum.

5. Threshold Surface: Fluted horizontal grooves across full width.

6. Field cut threshold to profile of frame and width of door sill for tight fit.

7. Provide non-corroding fasteners at exterior locations.

2.09 WEATHERSTRIPPING AND GASKETING

A. Weatherstripping and Gasketing: Comply with BHMA A156.22.

1. Head and Jamb Type: Adjustable.

2. Door Sweep Type: Door shoe with drip cap.

Page

Door Hardware 08 7100

3. Material: Aluminum, with neoprene weatherstripping.

4. Provide weatherstripping on each exterior door at head, jambs, and meeting stiles of door pairs, unless otherwise indicated.

5. Provide door bottom sweep on each exterior door, unless otherwise indicated.

2.10 RAIN GUARD

A. Rain Guard: Comply with BHMA A156.22.

1. Head: Adjustable.

2. Material: Aluminum.

B. Provide door rain guard on each exterior door, unless otherwise indicated.

C. Provide applicable gasketing on doors indicated as "Lightproof."

2.11 SILENCERS

A. Silencers: Provide at equal locations on door frame to mute sound of door's impact upon closing.

1. Single Door: Provide three on strike jamb of frame.

2. Material: Rubber, gray color.

2.12 FINISHES

A. Finishes: Provide door hardware of same finish, unless otherwise indicated.

1. Finish: 626; satin chromium plated over nickel, with brass or bronze base material (former US equivalent US26D); BHMA A156.18.

2. Exceptions:

a. Where base material metal is specified to be different, provide finish that is an equivalent appearance in accordance with BHMA A156.18.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verify that doors and frames are ready to receive this work; labeled, fire-rated doors and frames are properly installed, and dimensions are as indicated on shop drawings.

3.02 INSTALLATION

A. Install hardware in accordance with manufacturer's instructions and applicable codes.

B. Use templates provided by hardware item manufacturer.

C. Do not install surface mounted items until application of finishes to substrate are fully completed.

D. Door Hardware Mounting Heights: Distance from finished floor to center line of hardware item.

As indicated in following list; unless noted otherwise in Door Hardware Schedule or on drawings.

1. Mounting heights in compliance with ADA Standards:

a. Locksets: 40-5/16 inch.

b. Exit Devices: 40-5/16 inch.

E. Set exterior door thresholds with full-width bead of elastomeric sealant at each point of contact with floor providing a continuous weather seal; anchor thresholds with stainless steel countersunk screws.

3.03 ADJUSTING

A. Adjust hardware for smooth operation.

B. Adjust gasketing for complete, continuous seal; replace if unable to make complete seal.

3.04 CLEANING

A. Clean adjacent surfaces soiled by hardware installation.

Page

Door Hardware 08 7100

3.05 PROTECTION

A. Protect finished Work under provisions of Section 01 7000 - Execution and Closeout

Requirements.

B. Do not permit adjacent work to damage hardware or finish.

END OF SECTION

Page

Glazing 08 8000

SECTION 08 8000

GLAZING

PART 1 GENERAL

1.01 SECTION INCLUDES

A. Glazing units.

B. Glazing compounds.

1.02 RELATED REQUIREMENTS

A. Section 08 1113 - Hollow Metal Doors and Frames: Glazed lites in doors and borrowed lites.

1.03 REFERENCE STANDARDS

A. 16 CFR 1201 - Safety Standard for Architectural Glazing Materials; Current Edition.

B. ANSI Z97.1 - American National Standard for Safety Glazing Materials Used in Buildings -

Safety Performance Specifications and Methods of Test; 2015 (Reaffirmed 2020).

C. ASTM C864 - Standard Specification for Dense Elastomeric Compression Seal Gaskets, Setting Blocks, and Spacers; 2005 (Reapproved 2026).

D. ASTM C920 - Standard Specification for Elastomeric Joint Sealants; 2018 (Reapproved 2024).

E. ASTM C1036 - Standard Specification for Flat Glass; 2025.

F. ASTM C1048 - Standard Specification for Heat-Strengthened and Fully Tempered Flat Glass;

2025.

G. ASTM C1193 - Standard Guide for Use of Joint Sealants; 2025.

H. ASTM E84 - Standard Test Method for Surface Burning Characteristics of Building Materials;

2026a.

I. ASTM E1300 - Standard Practice for Determining Load Resistance of Glass in Buildings; 2024.

J. ASTM E2190 - Standard Specification for Insulating Glass Unit Performance and Evaluation;

2019.

K. GANA (GM) - GANA Glazing Manual; 2022.

L. GANA (SM) - GANA Sealant Manual; 2008.

M. IGMA TM-3000 - North American Glazing Guidelines for Sealed Insulating Glass Units for

Commercial & Residential Use; 1990 (Reaffirmed 2016).

1.04 SUBMITTALS

A. Product Data on Insulating Glass Unit and Glazing Unit Glazing Types: Provide structural, physical and environmental characteristics, size limitations, special handling and installation requirements.

B. Product Data on Glazing Compounds and Accessories: Provide chemical, functional, and environmental characteristics, limitations, special application requirements, and identify available colors.

C. Certificate: Certify that products of this section meet or exceed specified requirements.

D. Warranty Documentation: Submit manufacturer warranty and ensure that forms have been completed in Owner's name and registered with manufacturer.

E. Maintenance Materials: Furnish the following for Owner's use in maintenance of project.

1.05 QUALITY ASSURANCE

A. Perform Work in accordance with GANA (GM), GANA (SM), GANA (LGRM), and IGMA TM-

3000 for glazing installation methods. Maintain one copy on site.

B. Manufacturer Qualifications: Company specializing in manufacturing the products specified in this section with minimum five years of documented experience.

Page

Glazing 08 8000

C. Installer Qualifications: Company specializing in performing work of type specified, with minimum 3 years of documented experience.

1.06 FIELD CONDITIONS

A. Do not install glazing when ambient temperature is less than 40 degrees F.

B. Maintain minimum ambient temperature before, during and 24 hours after installation of glazing compounds.

1.07 WARRANTY

A. Insulating Glass Units: Provide a ten (10) year manufacturer warranty to include coverage for seal failure, interpane dusting or misting, including providing products to replace failed units.

PART 2 PRODUCTS

2.01 GLASS MATERIALS

A. Float Glass: Provide float glass based glazing unless otherwise indicated.

1. Fully Tempered Safety Glass: Complies with ANSI Z97.1 or 16 CFR 1201 criteria for safety glazing used in hazardous locations.

2. Thicknesses: As indicated; provide greater thickness as required for exterior glazing wind load design.

2.02 GLAZING UNITS

A. Type G-1 - Monolithic Exterior Vision Glazing:

1. Applications: Exterior glazing unless otherwise indicated.

2. Glass Type: Fully tempered float glass.

3. Tint: Clear.

4. Thickness: 1/4 inch, nominal.

5. Visible Light Transmittance (VLT): 91 percent, nominal.

6. Visible Light Reflectance, Outside: 8 percent, nominal.

7. Glazing Method: Dry glazing method, gasket glazing.

2.03 ACCESSORIES

A. Setting Blocks: Neoprene, with 80 to 90 Shore A durometer hardness; ASTM C864 Option II.

Length of 0.1 inch for each square foot of glazing or minimum 4 inch by width of glazing rabbet space minus 1/16 inch by height to suit glazing method and pane weight and area.

B. Spacer Shims: Neoprene, 50 to 60 Shore A durometer hardness; ASTM C864 Option II.

Minimum 3 inch long by one half the height of the glazing stop by thickness to suit application, self adhesive on one face.

C. Glazing Splines: Resilient silicone extruded shape to suit glazing channel retaining slot; ASTM C864 Option II; color black.

D. Glazing Clips: Manufacturer's standard type.

PART 3 EXECUTION

3.01 VERIFICATION OF CONDITIONS

A. Verify that openings for glazing are correctly sized and within tolerances, including those for size, squareness, and offsets at corners.

B. Verify that surfaces of glazing channels or recesses are clean, free of obstructions that may impede moisture movement, weeps are clear, and support framing is ready to receive glazing system.

C. Proceed with glazing system installation only after unsatisfactory conditions have been corrected.

3.02 PREPARATION

A. Clean contact surfaces with appropriate solvent and wipe dry within maximum of 24 hours before glazing. Remove coatings that are not tightly bonded to substrates.

Page

Glazing 08 8000

B. Seal porous glazing channels or recesses with substrate compatible primer or sealer.

C. Prime surfaces scheduled to receive sealant where required for proper sealant adhesion.

3.03 INSTALLATION, GENERAL

A. Install glazing in compliance with written instructions of glass, gaskets, and other glazing material manufacturers, unless more stringent requirements are indicated, including those in glazing referenced standards.

B. Do not exceed edge pressures around perimeter of glass lites as stipulated by glass manufacturer.

C. Set glass lites in proper orientation so that coatings face exterior or interior as indicated.

D. Prevent glass from contact with any contaminating substances that may be the result of construction operations such as, and not limited to the following; weld splatter, fire-safing, plastering, mortar droppings, and paint.

3.04 INSTALLATION - DRY GLAZING METHOD (GASKET GLAZING)

A. Application - Exterior and/or Interior Glazed: Set glazing infills from either the exterior or the interior of the building.

B. Place setting blocks at 1/4 points with edge block no more than 6 inch from corners.

C. Rest glazing on setting blocks and push against fixed stop with sufficient pressure on gasket to attain full contact.

D. Install removable stops without displacing glazing gasket; exert pressure for full continuous contact.

3.05 FIELD QUALITY CONTROL

A. Glass and Glazing product manufacturers to provide field surveillance of the installation of their products.

B. Monitor and report installation procedures and unacceptable conditions.

3.06 CLEANING

A. Remove excess glazing materials from finish surfaces immediately after application using solvents or cleaners recommended by manufacturers.

B. Remove nonpermanent labels immediately after glazing installation is complete.

C. Clean glass and adjacent surfaces after sealants are fully cured.

D. Clean glass on both exposed surfaces not more than 4 days prior to Date of Substantial

Completion in accordance with glass manufacturer's written recommendations.

3.07 PROTECTION

A. After installation, mark pane with an 'X' by using removable plastic tape or paste; do not mark heat absorbing or reflective glass units.

B. Remove and replace glass that is damaged during construction period prior to Date of Substantial Completion.

END OF SECTION